{"id":43362,"date":"2025-04-08T00:00:00","date_gmt":"2025-04-08T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\/"},"modified":"2025-11-25T20:52:52","modified_gmt":"2025-11-25T20:52:52","slug":"lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4420-ja\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan","title":{"rendered":"\u5168\u8840\u30fb\u5c3f\u4e2dTHC\u7570\u6027\u4f53\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306e\u9ad8\u611f\u5ea6LC-MS\/MS\u30e1\u30bd\u30c3\u30c9"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">THC\u306e\u4ee3\u8b1d\u7269\u691c\u67fb\u306e\u91cd\u8981\u6027\u306f\u3001\u6cd5\u533b\u5b66\u30fb\u533b\u7642\u73fe\u5834\u306b\u304a\u3044\u3066\u8fd1\u5e74\u307e\u3059\u307e\u3059\u9ad8\u307e\u3063\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u03948-THC\u3001\u03949-THC\u306a\u3069\u306e\u7570\u6027\u4f53\u304a\u3088\u3073\u305d\u308c\u3089\u306e\u4ee3\u8b1d\u7269\u306f\u5316\u5b66\u69cb\u9020\u304c\u975e\u5e38\u306b\u985e\u4f3c\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u5f93\u6765\u306e\u5206\u6790\u6cd5\u3067\u306f\u6b63\u78ba\u306b\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u3067\u3059\u3002\u305d\u3053\u3067\u672c\u7814\u7a76\u3067\u306f\u3001\u3053\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3059\u308b\u305f\u3081\u306b\u3001\u5168\u8840\u304a\u3088\u3073\u5c3f\u30b5\u30f3\u30d7\u30eb\u3092\u5bfe\u8c61\u3068\u3057\u305f\u65b0\u305f\u306aLC-MS\/MS\u5206\u6790\u6cd5\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb(\u03949-THC)\u306e\u6442\u53d6\u306b\u95a2\u3059\u308b\u8840\u6db2\u304a\u3088\u3073\u5c3f\u306e\u691c\u67fb\u306f\u3001\u85ac\u7269\u4f7f\u7528\u306e\u5224\u5b9a\u3084\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u306e\u624b\u6cd5\u3068\u3057\u3066\u9577\u5e74\u7528\u3044\u3089\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u4f53\u5185\u306b\u53d6\u308a\u8fbc\u307e\u308c\u305f\u03949-THC\u306f\u300111-\u30ce\u30eb-9-\u30ab\u30eb\u30dc\u30ad\u30b7-\u03949-THC\uff08\u03949-THC-COOH\uff09\u3078\u3068\u4ee3\u8b1d\u3055\u308c\u3001\u3053\u308c\u3089\u304c\u8840\u6db2\u3084\u5c3f\u304b\u3089\u691c\u51fa\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u3001\u03949-THC\u3068\u305d\u306e\u4ee3\u8b1d\u7269\u3067\u3042\u308b\u03949-THC-COOH\u306e\u4e8c\u3064\u3060\u3051\u304c\u3001THC\u6442\u53d6\u5224\u5b9a\u306e\u4e3b\u8981\u6307\u6a19\u3068\u3055\u308c\u3066\u304d\u307e\u3057\u305f [1]\u3002\u3057\u304b\u3057\u3001\u3088\u308a\u591a\u69d8\u306a\u03949-THC\u7570\u6027\u4f53\u304c\u5e02\u5834\u3067\u6d41\u901a\u3059\u308b\u3088\u3046\u306b\u306a\u3063\u305f\u3053\u3068\u3067\u3001\u691c\u67fb\u306f\u6025\u6fc0\u306b\u8907\u96d1\u5316\u3057\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u30d8\u30f3\u30d7\uff08\u9ebb\uff09\u7531\u6765\u88fd\u54c1\u3092\u5408\u6cd5\u5316\u3057\u305f2018\u5e74\u306e\u8fb2\u696d\u6cd5\u6848\u306e\u6210\u7acb\u4ee5\u964d\u3001\u305d\u306e\u898f\u5236\u306e\u629c\u3051\u7a74\u3092\u5229\u7528\u3057\u305f\u65b0\u305f\u306a\u7570\u6027\u4f53\u306e\u6d41\u901a\u304c\u554f\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e00\u3064\u3067\u3042\u308b\u03948-THC\u306f\u3001\u4f53\u5185\u306b\u53d6\u308a\u8fbc\u307e\u308c\u308b\u306811-\u30ce\u30eb-9-\u30ab\u30eb\u30dc\u30ad\u30b7-\u03948-THC\uff08\u03948-THC-COOH\uff09\u3068\u3044\u3046\u4ee3\u8b1d\u7269\u306b\u5909\u63db\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u03948-THC-COOH\u306f\u3001\u5f93\u6765\u306e\u4e3b\u8981\u6307\u6a19\u3067\u3042\u308b\u03949-THC-COOH\u3068\u5316\u5b66\u69cb\u9020\u304c\u975e\u5e38\u306b\u985e\u4f3c\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u308c\u30892\u3064\u306e\u4ee3\u8b1d\u7269\u5206\u96e2\u304c\u4e0d\u5341\u5206\u306a\u5834\u5408\u3001\u7279\u306b\u4e00\u65b9\u306e\u7570\u6027\u4f53\u304c\u9ad8\u6fc3\u5ea6\u3067\u5b58\u5728\u3059\u308b\u72b6\u6cc1\u4e0b\u3067\u306f\u3001\u691c\u67fb\u7d50\u679c\u304c\u8aa4\u3063\u305f\u89e3\u91c8\u306b\u3064\u306a\u304c\u308b\u30ea\u30b9\u30af\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u81e8\u5e8a\u691c\u67fb\u30e9\u30dc\u3084\u6bd2\u7269\u691c\u67fb\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u4e8b\u4ef6\u767a\u751f\u5f8c\u306b\u63a1\u53d6\u3057\u305f\u8840\u6db2\u691c\u4f53\u3092\u7528\u3044\u3066\u3001\u5bfe\u8c61\u8005\u304c\u5927\u9ebb\u306e\u5f71\u97ff\u4e0b\u306b\u3042\u3063\u305f\u304b\u3069\u3046\u304b\u3092\u5224\u5b9a\u3067\u304d\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u306e\u3088\u3046\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u306f\u3001\u4ed6\u306e\u4e00\u822c\u7684\u306a\u4e8b\u4ef6\u5f53\u6642\u306e\u691c\u67fb\u3068\u6bd4\u3079\u3066\u5bb9\u6613\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3068\u3044\u3046\u306e\u3082\u3001\u03949-THC\u306f\u4f53\u5185\u306b\u53d6\u308a\u8fbc\u307e\u308c\u308b\u3068\u6025\u901f\u306b\u8840\u4e2d\u6fc3\u5ea6\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u304c\u3001\u305d\u306e\u4ee3\u8b1d\u904e\u7a0b\u306f\u975e\u7dda\u5f62\u3067\u500b\u4eba\u5dee\u3082\u5927\u304d\u3044\u305f\u3081\u3001\u6442\u53d6\u6642\u671f\u3084\u66dd\u9732\u6642\u9593\u3092\u6b63\u78ba\u306b\u63a8\u5b9a\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059[1]\u3002\u3055\u3089\u306b\u3001\u30d8\u30d3\u30fc\u30e6\u30fc\u30b6\u30fc\u306e\u5834\u5408\u3001\u6700\u7d42\u63a5\u7a2e\u304b\u308933\u65e5\u5f8c\u306bTHC\u304c\u3001\u307e\u305f\u7d0430\u65e5\u5f8c\u306b\u5c3f\u304b\u3089\u03949-THC-COOH\u304c\u691c\u51fa\u3055\u308c\u305f\u4f8b\u3082\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u3001\u691c\u4f53\u63a1\u53d6\u6642\u70b9\u3067\u5bfe\u8c61\u8005\u304c\u5927\u9ebb\u306e\u5f71\u97ff\u4e0b\u306b\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3059\u308b\u6307\u6a19\u3068\u3057\u3066\u306f\u9069\u3057\u3066\u3044\u307e\u305b\u3093[1,2]\u3002\u03949-THC\u306f\u4f53\u5185\u306b\u5165\u308b\u3068\u9178\u5316\u3055\u308c\u3001\u77ed\u547d\u306a\u4e2d\u9593\u4ee3\u8b1d\u7269\u3067\u3042\u308b11-\u30d2\u30c9\u30ed\u30ad\u30b7-\u03949-\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff0811-OH-\u03949-THC\uff09\u3068\u306a\u308a\u3001\u6700\u7d42\u7684\u306b\u03949-THC-COOH\u306b\u4ee3\u8b1d\u3055\u308c\u307e\u3059\u300211-OH-\u03949-THC\u5358\u72ec\u3067\u306f\u3001\u5927\u9ebb\u306e\u6b63\u78ba\u306a\u6442\u53d6\u6642\u671f\u3084\u66dd\u9732\u6642\u9593\u3092\u6b63\u78ba\u306b\u63a8\u5b9a\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u304c\u3001\u3053\u306e\u4ee3\u8b1d\u7269\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u3001\u5bfe\u8c61\u8005\u304c\u6700\u8fd1\u5927\u9ebb\u3092\u6442\u53d6\u3057\u305f\u53ef\u80fd\u6027\u3092\u793a\u3059\u6709\u529b\u306a\u624b\u304c\u304b\u308a\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u30012\u3064\u306e\u5206\u6790\u65b9\u6cd5\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u5c3f\u4e2d\u306e\u03948-THC\u3068\u03949-THC\u306e\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\uff08\u03949-THC-COOH\/\u03948-THC-COOH\uff09\u306e\u4e21\u65b9\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u5206\u6790\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u30012\u3064\u306e\u7570\u6027\u4f53\u9593\u3067\u5341\u5206\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u7570\u6027\u4f53\u306e\u4e00\u65b9\u304c\u975e\u5e38\u306b\u9ad8\u6fc3\u5ea6\u3067\u5b58\u5728\u3057\u3066\u3082\u3001\u5b9a\u91cf\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u3068\u5b89\u5b9a\u6027\u306f\u7dad\u6301\u3055\u308c\u307e\u3059\u3002\u6b21\u306b\u958b\u767a\u3057\u305f\u306e\u306f\u3001\u89aa\u5316\u5408\u7269(\u03948-THC\/\u03949-THC)\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269(11-OH-\u03949-THC\/11-OH-\u03948-THC)\u3001\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269(\u03949-THC-COOH\/\u03948-THC-COOH)\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u305f\u3081\u306e\u3001\u5168\u8840\u3092\u5bfe\u8c61\u3068\u3057\u305f\u5206\u6790\u65b9\u6cd5\u3067\u3059\u3002\u5b9f\u9a13\u8a73\u7d30\u3068\u305d\u306e\u7d50\u679c\u3068\u5171\u306b\u3001\u5404\u5206\u6790\u65b9\u6cd5\u3092\u8a73\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u65b9\u6cd5<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>1. \u5c3f<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c3f\u4e2d\u306e\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u5206\u6790\u6761\u4ef6\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u5c3f\u4e2d\u306e\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u4ee3\u8b1d\u7269\uff08\u6fc3\u5ea650 ng\/mL\uff09\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff08\u5206\u6790\u6761\u4ef6\u306f\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0828.png\" alt=\"\u03948-THC-COOH and \u03949-THC-COOH Isomers in Urine on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0828<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">4.44<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">5.12<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>THC Isomers<\/li><li>fluorophenyl<\/li><li>urine drug testing<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0828.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2. \u8840\u6db2<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5168\u8840\u4e2d\u306e\u03949-THC\/\u03948-THC\u3001\u03949-THC-COOH\/\u03948-THC-COOH\u300111-OH-\u03949-THC\/11-OH-\u03948-THC\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306e\u5206\u6790\u6761\u4ef6\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u5168\u8840\u4e2d\u306e\u5316\u5408\u7269\u03948-THC\u3001\u03949-THC\u300111-OH-\u03949-THC\u300111-OH-\u03948-THC\uff08\u6fc3\u5ea650 ng\/mL\uff09\u3068\u03948-THC-COOH\u3001\u03949-THC-COOH\uff08\u6fc3\u5ea6250 ng\/mL\uff09\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff08\u5206\u6790\u6761\u4ef6\u306f\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.png\" alt=\"\u03949-THC; \u03948-THC; Hydroxy- and Carboxy- Metabolites in Whole Blood on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0826<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">10.88<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">11.26<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>FluoroPhenyl<\/li><li>THC Isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u6a19\u6e96\u7269\u8cea\uff08\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u3001QC\u7528\u6a19\u6e96\u6eb6\u6db2\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306f\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>1. \u5c3f<\/strong><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">\u5c3f\u6821\u6b63\u7528\u30b5\u30f3\u30d7\u30eb\u304a\u3088\u3073QC\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d6\u30e9\u30f3\u30af\u306e\u30d2\u30c8\u5c3f\u306b\u3055\u307e\u3056\u307e\u306a\u6fc3\u5ea6\u306e\u6a19\u6e96\u7269\u8cea\u3092\u6dfb\u52a0\u3057\u3001\u691c\u91cf\u7dda\u7bc4\u56f2\u5185\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u5404\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-COOH-D9 \u6fc3\u5ea6:1000ng\/mL\uff0950 \u03bcL\u3092\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u52a0\u6c34\u5206\u89e3\u5c3fQC\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30eb\u30af\u30ed\u30cb\u30c9\u967d\u6027\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-COOH-\u30b0\u30eb\u30af\u30ed\u30cb\u30c9\uff09\u3092750ng\/mL\uff08\u904a\u96e2\u6642\uff09\u306e\u6fc3\u5ea6\u306b\u306a\u308b\u3088\u3046\u306b\u30d6\u30e9\u30f3\u30af\u5c3f\u306b\u6dfb\u52a0\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-COOH-D9 \u6fc3\u5ea6:1000ng\/mL\uff0950 \u03bcL\u3092\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u60a3\u8005\u7531\u6765\u5c3f\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a3\u8005\u304b\u3089\u63a1\u53d6\u3057\u305f\u5c3f\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-COOH-D9 \u6fc3\u5ea6:1000ng\/mL\uff0950 \u03bcL\u3092\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u5c3f\u30b5\u30f3\u30d7\u30eb\u306e\u30a2\u30eb\u30ab\u30ea\u52a0\u6c34\u5206\u89e3\u624b\u9806<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">THC\u306f\u4f53\u5185\u3067\u4ee3\u8b1d\u3055\u308c\u308b\u904e\u7a0b\u3067\u30b0\u30eb\u30af\u30ed\u30f3\u9178\u62b1\u5408\u4f53\u3068\u3057\u3066\u5c3f\u4e2d\u306b\u6392\u6cc4\u3055\u308c\u308b\u305f\u3081\u3001\u6b63\u78ba\u306a\u5206\u6790\u3092\u884c\u3046\u306b\u306f\u3001\u5c3f\u691c\u4f53\u3092\u62bd\u51fa\u3059\u308b\u524d\u306e\u52a0\u6c34\u5206\u89e3\u51e6\u7406\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u30a2\u30eb\u30ab\u30ea\u52a0\u6c34\u5206\u89e3\u3067\u3053\u306e\u51e6\u7406\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u5c3f\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u306b\u300110N\u6c34\u9178\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\uff08NaOH\uff0940 \u03bcL\u3092\u6dfb\u52a0\u3057\u307e\u3057\u305f\u3002\u30ad\u30e3\u30c3\u30d7\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u305f\u5f8c\u300160\u2103\u306720\u5206\u9593\u4fdd\u6e29\uff08\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30c8\uff09\u3057\u3001\u30b0\u30eb\u30af\u30ed\u30f3\u9178\u62b1\u5408\u4f53\u3092\u904a\u96e2\u578b\u3078\u3068\u5909\u63db\u3001\u4fdd\u6e29\u5b8c\u4e86\u5f8c\u3001\u51b7\u5374\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306b\u6c37\u9162\u917825 \u03bcL\u3092\u6dfb\u52a0\u3057\u3001pH\u3092\u4e2d\u548c\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u52a0\u6c34\u5206\u89e3\u30b5\u30f3\u30d7\u30eb12 mL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u79fb\u3057\u3001\u6db2\u6db2\u62bd\u51fa\uff08LLE\uff09\u3067\u306e\u62bd\u51fa\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u5c3f\u30b5\u30f3\u30d7\u30eb\u306eLLE\u624b\u9806<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">HPLC\u30b0\u30ec\u30fc\u30c9\u306e\u6c34500 \u03bcL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002\u7d9a\u3044\u3066\u5404\u8a66\u9a13\u7ba1\u306b10\uff05\u9162\u9178100 \u03bcL\u3092\u6dfb\u52a0\u3057\u3001\u518d\u5ea6\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u3001\u30d8\u30ad\u30b5\u30f3:\u9162\u9178\u30a8\u30c1\u30eb\u309280:20\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db22.5 mL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u6dfb\u52a0\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u8a66\u9a13\u7ba1\u306b\u30ad\u30e3\u30c3\u30d7\u3092\u3057\u3066\u3001\u76ee\u8996\u3067\u6df7\u5408\u304c\u78ba\u8a8d\u3067\u304d\u308b\u307e\u3067\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002\u7d9a\u3044\u3066\u3001\u5404\u30b5\u30f3\u30d7\u30eb\u30922800 rpm\u306715\u5206\u9593\u3001\u307e\u305f\u306f2\u3064\u306e\u5c64\u304c\u5b8c\u5168\u306b\u5206\u96e2\u3059\u308b\u307e\u3067\u9060\u5fc3\u5206\u96e2\u3057\u3001\u4e0a\u6e05\u3092\u6e05\u6f54\u306a\u8a66\u9a13\u7ba1\u306b\u79fb\u3057\u305f\u5f8c\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u7a92\u7d20\u4e0b\u3067\u4e7e\u56fa\u3057\u307e\u3057\u305f\u3002\u4e7e\u56fa\u5f8c\u30010.1%\u30ae\u9178\u3092\u542b\u3080\u6c34:\u30e1\u30bf\u30ce\u30fc\u30eb\u309240:60\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2100 \u00b5L\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u518d\u6eb6\u89e3\u3057\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002\u6700\u5f8c\u306b\u3001\u518d\u6eb6\u89e3\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092LC\u30d0\u30a4\u30a2\u30eb\u30a4\u30f3\u30b5\u30fc\u30c8\u306b\u79fb\u3057\u3001LC-MS\/MS\u306b\u3088\u308b\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>2. \u8840\u6db2<\/strong><\/h4>\n\n\n\n<h4 class=\"wp-block-heading\">\u8840\u6db2\u6821\u6b63\u7528\u30b5\u30f3\u30d7\u30eb\u304a\u3088\u3073QC\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d6\u30e9\u30f3\u30af\u306e\u30d2\u30c8\u8840\u6db2\uff08K2\u30fbEDTA\u3092\u542b\u3080\uff09\u306b\u3055\u307e\u3056\u307e\u306a\u6fc3\u5ea6\u306e\u6a19\u6e96\u7269\u8cea\u3092\u6dfb\u52a0\u3057\u3001\u691c\u91cf\u7dda\u7bc4\u56f2\u5185\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u5404\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-D3\u300111-OH-\u03949-THC-D3\u3001\u03949-THC-COOH-D3 \u6fc3\u5ea6:1000ng\/mL\uff0950 \u03bcL\u3092\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u60a3\u8005\u7531\u6765\u8840\u6db2\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u60a3\u8005\u304b\u3089\u63a1\u53d6\u3057\u305f\u8840\u6db2\u30b5\u30f3\u30d7\u30eb500 \u03bcL\u3092\u30ac\u30e9\u30b9\u88fd\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u03949-THC-D3\u300111-OH-\u03949-THC-D3\u3001\u03949-THC-COOH-D3 \u6fc3\u5ea6:1000ng\/mL\uff0950 \u03bcL\u3092\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u305f\u5f8c\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u8840\u6db2\u30b5\u30f3\u30d7\u30eb\u306eLLE\u624b\u9806<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">HPLC\u30b0\u30ec\u30fc\u30c9\u306e\u6c34500 \u03bcL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u52a0\u3048\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u305f\u306e\u3061\u300110\uff05\u9162\u9178100 \u03bcL\u3092\u6dfb\u52a0\u3057\u3001\u518d\u5ea6\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3057\u307e\u3057\u305f\u3002\u30d8\u30ad\u30b5\u30f3:\u9162\u9178\u30a8\u30c1\u30eb\u309280:20\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db22.5 mL\u3092\u5404\u8a66\u9a13\u7ba1\u306b\u6dfb\u52a0\u5f8c\u3001\u8a66\u9a13\u7ba1\u306b\u30ad\u30e3\u30c3\u30d7\u3092\u3057\u3066\u3001\u76ee\u8996\u3067\u6df7\u5408\u304c\u78ba\u8a8d\u3067\u304d\u308b\u307e\u3067\u64b9\u62cc\uff08\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\uff09\u3057\u307e\u3057\u305f\u3002\u6b21\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u30922800rpm\u306715\u5206\u9593\u3001\u307e\u305f\u306f2\u3064\u306e\u5c64\u304c\u5b8c\u5168\u306b\u5206\u96e2\u3059\u308b\u307e\u3067\u9060\u5fc3\u5206\u96e2\u3057\u3001\u5404\u30b5\u30f3\u30d7\u30eb\u306e\u4e0a\u6e05\u3092\u6e05\u6f54\u306a\u8a66\u9a13\u7ba1\u306b\u79fb\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u7a92\u7d20\u4e0b\u3067\u4e7e\u56fa\u3057\u30010.1%\u30ae\u9178\u3092\u542b\u3080\u3001\u6c34:\u30e1\u30bf\u30ce\u30fc\u30eb\u309240:60\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2100\u00b5L\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u518d\u6eb6\u89e3\u3057\u307e\u3057\u305f\u3002\u6700\u5f8c\u306b\u3001\u518d\u6eb6\u89e3\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u64b9\u62cc\uff08\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\uff09\u3057\u3066LC\u30d0\u30a4\u30a2\u30eb\u30a4\u30f3\u30b5\u30fc\u30c8\u306b\u79fb\u3057\u3001LC-MS\/MS\u306b\u3088\u308b\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. \u5c3f\u3000<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor FluoroPhenyl 2.7 \u00b5m, 100 x 3.0 mm\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f6.5\u5206\u306e\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\uff08\u7dcf\u5206\u6790\u6642\u95938.5\u5206\uff09\u3067\u5206\u6790\u3092\u884c\u3063\u305f\u7d50\u679c\u30012\u3064\u306e\u7570\u6027\u4f53\u306f\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u5f97\u3089\u308c\u305f\u5206\u96e2\u5ea6\u306f\u3001\u5c3f\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3044\u3066\u6642\u6298\u898b\u3089\u308c\u308b\u7570\u6027\u4f53\u306e\u6fc3\u5ea6\u306b\u6975\u7aef\u306a\u5dee\u304c\u3042\u308b\u5834\u5408\u3067\u3082\u30012\u3064\u306e\u5206\u6790\u6210\u5206\u9593\u306e\u5b9a\u91cf\u7684\u306a\u5e72\u6e09\u3092\u5341\u5206\u306b\u9632\u3050\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 3<\/strong>\u304a\u3088\u3073<strong>Figure&nbsp;4<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> \u6975\u7aef\u306a\u7570\u6027\u4f53\u6fc3\u5ea6\u6bd4\uff08\u03948-THC-COOH\uff08\u6fc3\u5ea61 ng\/mL\uff09: \u03949-THC-COOH\uff08\u6fc3\u5ea61000 ng\/mL\uff09\uff09\u3067\u3082\u4e92\u3044\u306b\u3088\u304f\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u03948-THC-COOH\u3068\u03949-THC-COOH\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0831.png\" alt=\"1000 ng\/mL \u03948-THC-COOH and 10 ng\/mL \u03949-THC-COOH in Urine on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0831<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0831.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> \u6975\u7aef\u306a\u7570\u6027\u4f53\u6fc3\u5ea6\u6bd4\uff08\u03949-THC-COOH\uff08\u6fc3\u5ea61 ng\/mL\uff09\uff1a\u03948-THC-COOH\uff08\u6fc3\u5ea61000 ng\/mL\uff09\uff09\u3067\u3082\u4e92\u3044\u306b\u3088\u304f\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u03948-THC-COOH\u3068\u03949-THC-COOH\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0832.png\" alt=\"10 ng\/mL \u03948-THC-COOH and 1000 ng\/mL \u03949-THC-COOH in Urine on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0832<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0832.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u76f4\u7dda\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1\/x \u91cd\u307f\u4ed8\u3051\u7dda\u5f62\u56de\u5e30\u3092\u7528\u3044\u3066\u76f4\u7dda\u6027\u3092\u78ba\u8a8d\u3057\u305f\u3068\u3053\u308d\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30010.99\u4ee5\u4e0a\u306e\u8a31\u5bb9\u53ef\u80fd\u306ar<sup>2<\/sup>\u5024\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u512a\u308c\u305f\u76f4\u7dda\u6027\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u306e\u6821\u6b63\u7bc4\u56f2\u306f\u6fc3\u5ea65\uff5e1000 ng\/mL\uff08\u5c3f\u691c\u4f53\u4e2d\u306b\u304a\u3051\u308b\u5178\u578b\u7684\u306a\u6fc3\u5ea6\u5206\u5e03\u3092\u30ab\u30d0\u30fc\uff09\u306b\u8a2d\u5b9a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u5e72\u6e09\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001\u30d6\u30e9\u30f3\u30af\u5c3f\u30b5\u30f3\u30d7\u30eb3\u691c\u4f53\u3092\u524d\u51e6\u7406\u3057\u3066\u5206\u6790\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u7531\u6765\u3057\u306a\u3044\u30b7\u30b0\u30ca\u30eb\u306e\u6709\u7121\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u307e\u305f\u3001\u3082\u3063\u3068\u3082\u9ad8\u3044\u6821\u6b63\u6fc3\u5ea6\uff081000 ng\/mL\uff09\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u5f8c\u306b\u30e1\u30bf\u30ce\u30fc\u30eb\u30d6\u30e9\u30f3\u30af\u3092\u6ce8\u5165\u3057\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u305f\u3068\u3053\u308d\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306f\u89b3\u5bdf\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u518d\u73fe\u6027\u3068\u7cbe\u5ea6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u306e\u8a55\u4fa1\u306f\u3001LLOQ\uff08\u5b9a\u91cf\u4e0b\u9650\uff09\u3001Low QC\uff08\u4f4e\u6fc3\u5ea6QC\uff09\u3001Medium QC\uff08\u4e2d\u6fc3\u5ea6QC\uff09\u3001High QC\uff08\u9ad8\u6fc3\u5ea6QC\uff09\u306e\u30014\u3064\u306e\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u5404\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u3001\u65e5\u5185\u304a\u3088\u30733\u65e5\u9593\u306e\u6e2c\u5b9a\uff08N=9\uff09\u306e\u5e73\u5747\u5024\u3092\u7528\u3044\u3066\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u306f\u3001\u65e2\u77e5\u6fc3\u5ea6\u306b\u5bfe\u3059\u308b\u5b9f\u6e2c\u5b9a\u91cf\u6fc3\u5ea6\u306e\u30d1\u30fc\u30bb\u30f3\u30c6\u30fc\u30b8\uff08%\uff09\u3068\u3057\u3066\u5b9a\u7fa9\u3055\u308c\u3001\u65e5\u9593\u518d\u73fe\u6027\u306f\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u306b\u3088\u3063\u3066\u793a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u7d50\u679c\u3088\u308a\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u304c\u3001\u691c\u8a0e\u3057\u305f\u6fc3\u5ea6\u7bc4\u56f2\u306b\u304a\u3044\u3066\u3001\u9ad8\u3044\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u3092\u6709\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\uff08<strong>Table I<\/strong>\u304a\u3088\u3073<strong>Table II<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u5c3f\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u65e5\u9593\u518d\u73fe\u6027\u306b\u95a2\u3059\u308b\u5b9f\u9a13\u7d50\u679c\uff08%RSD\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>LLOQ (5 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Low QC (25 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Med QC (250 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>High QC (750 ng\/mL)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC-COOH<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.14%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.81%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.87%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.76%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC-COOH<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.04%<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.13%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.56%<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.79%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u5c3f\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u306b\u95a2\u3059\u308b\u5b9f\u9a13\u7d50\u679c\uff08%R\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>LLOQ (5 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Low QC (25 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Med QC (250 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>High QC (750 ng\/mL)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC-COOH<\/td><td class=\"has-text-align-center\" data-align=\"center\">83.0%<\/td><td class=\"has-text-align-center\" data-align=\"center\">94.7%<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.6%<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC-COOH<\/td><td class=\"has-text-align-center\" data-align=\"center\">80.6%<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">90.5%<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.2%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. \u8840\u6db2<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor FluoroPhenyl 2.7 \u00b5m, 100 x 3.0 mm\u30ab\u30e9\u30e0\uff08cat.# 9319A1E\uff09\u3092\u7528\u3044\u305f13\u5206\u9593\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u5206\u96e2\uff08\u7dcf\u5206\u6790\u6642\u959316\u5206\uff09\u306b\u3088\u308a\u30013\u7d44\u306e\u7570\u6027\u4f53\u3001\u8a086\u7a2e\u985e\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u826f\u597d\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u76f4\u7dda\u6027\u3000<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">1\/x \u91cd\u307f\u4ed8\u3051\u7dda\u5f62\u56de\u5e30\u3092\u7528\u3044\u3066\u76f4\u7dda\u6027\u3092\u691c\u8a3c\u3057\u305f\u3068\u3053\u308d\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u304a\u3044\u3066\u30010.99\u4ee5\u4e0a\u306e\u8a31\u5bb9\u53ef\u80fd\u306ar<sup>2<\/sup>\u5024\u3092\u793a\u3057\u3001\u512a\u308c\u305f\u76f4\u7dda\u6027\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u300211-OH-\u03948-THC\u300111-OH-\u03949-THC\u3001\u03948-THC\u3001\u03949-TH\u306e\u6821\u6b63\u6fc3\u5ea6\u7bc4\u56f2\u306f0.5\uff5e100 ng\/mL\u306b\u3001\u03948-THC-COOH\u304a\u3088\u3073\u03949-THC-COOH\u306f2.5\uff5e500 ng\/mL\uff08\u8840\u6db2\u691c\u4f53\u4e2d\u306b\u304a\u3051\u308b\u5178\u578b\u7684\u306a\u6fc3\u5ea6\u5206\u5e03\u3092\u30ab\u30d0\u30fc\uff09\u306b\u305d\u308c\u305e\u308c\u8a2d\u5b9a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u5e72\u6e09\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u30d6\u30e9\u30f3\u30af\u8840\u6db2\u30b5\u30f3\u30d7\u30eb3\u691c\u4f53\u3092\u524d\u51e6\u7406\u3057\u3066\u5206\u6790\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u7531\u6765\u3057\u306a\u3044\u30b7\u30b0\u30ca\u30eb\u306e\u6709\u7121\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u304c\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u307e\u305f\u3001\u3082\u3063\u3068\u3082\u9ad8\u3044\u6821\u6b63\u6fc3\u5ea6\uff081000 ng\/mL\u307e\u305f\u306f500 ng\/mL\uff09\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u5f8c\u306b\u30e1\u30bf\u30ce\u30fc\u30eb\u30d6\u30e9\u30f3\u30af\u3092\u6ce8\u5165\u3057\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u305f\u3068\u3053\u308d\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306f\u89b3\u5bdf\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u518d\u73fe\u6027\u3068\u7cbe\u5ea6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u306e\u8a55\u4fa1\u306f\u3001LLOQ\uff08\u5b9a\u91cf\u4e0b\u9650\uff09\u3001Low QC\uff08\u4f4e\u6fc3\u5ea6QC\uff09\u3001Medium QC\uff08\u4e2d\u6fc3\u5ea6QC\uff09\u3001High QC\uff08\u9ad8\u6fc3\u5ea6QC\uff09\u306e\u30014\u3064\u306e\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u5404\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u3001\u65e5\u5185\u304a\u3088\u30733\u65e5\u9593\u306e\u6e2c\u5b9a\uff08N=9\uff09\u306e\u5e73\u5747\u5024\u3092\u7528\u3044\u3066\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u65e5\u9593\u518d\u73fe\u6027\u306f\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u3068\u3057\u307e\u3057\u305f\u3002<strong>Table III<\/strong>\u304a\u3088\u3073<strong>Table IV<\/strong>\u306e\u7d50\u679c\u304b\u3089\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u304c\u3001\u691c\u8a0e\u3057\u305f\u6fc3\u5ea6\u7bc4\u56f2\u306b\u304a\u3044\u3066\u3001\u9ad8\u3044\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u3092\u6709\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> \u5168\u8840\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u65e5\u9593\u6a19\u6e96\u504f\u5dee\u306b\u95a2\u3059\u308b\u5b9f\u9a13\u7d50\u679c\uff08%RSD\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>LLOQ (0.5\/2.5 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Low QC (5\/25 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Med QC (45\/225 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>High QC (75\/375 ng\/mL)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">11-OH-\u03948-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.73%<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.12%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.65%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.44%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">11-OH-\u03949-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.90%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.13%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.61%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.37%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC-COOH*<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.63%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.15%<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.20%<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.33%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC-COOH*<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.04%<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.13%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.78%<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.74%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">11.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.77%<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.89%<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.95%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.32%<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.00%<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.56%<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.23%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u6ce8\uff1a\u0394-8\/9-THC-COOH\u306e\u30bf\u30fc\u30b2\u30c3\u30c8QC\u6fc3\u5ea6\u306f5\u500d\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong> \u5168\u8840\u4e2d\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u306b\u95a2\u3059\u308b\u5b9f\u9a13\u7d50\u679c\uff08%\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>LLOQ (0.5\/2.5 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Low QC (5\/25 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Med QC (45\/225 ng\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>High QC (75\/375 ng\/mL)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">11-OH-\u03948-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.2%<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.6%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.3%<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.7%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">11-OH-\u03949-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">94.8%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.2%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.6%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC-COOH*<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.8%<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.0%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC-COOH*<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.6%<\/td><td class=\"has-text-align-center\" data-align=\"center\">95.9%<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.9%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03948-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">90.9%<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.4%<\/td><td class=\"has-text-align-center\" data-align=\"center\">94.4%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u03949-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">93.1%<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.8%<\/td><td class=\"has-text-align-center\" data-align=\"center\">98.2%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u6ce8\uff1a\u0394-8\/9-THC-COOH\u306e\u30bf\u30fc\u30b2\u30c3\u30c8QC\u6fc3\u5ea6\u306f5\u500d\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u5bfe\u8c61\u6210\u5206\u9593\u306e\u76f8\u4e92\u5e72\u6e09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u540c\u91cd\u4f53\u307e\u305f\u306f\u69cb\u9020\u7684\u306b\u985e\u4f3c\u3057\u305f12\u7a2e\u985e\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306b\u3088\u308b\u5e72\u6e09\u306b\u3064\u3044\u3066\u3082\u691c\u8a0e\u3057\u307e\u3057\u305f\u3002\u5177\u4f53\u7684\u306b\u306f\u3001\u30ab\u30f3\u30ca\u30d3\u30b8\u30d0\u30ea\u30f3\uff08CBDV\uff09\uff1b\u30ab\u30f3\u30ca\u30d3\u30b8\u30aa\u30fc\u30eb\uff08CBD\uff09\uff1b\u30ab\u30f3\u30ca\u30d3\u30b2\u30ed\u30fc\u30eb\uff08CBG\uff09\uff1b\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30d0\u30ea\u30f3\uff08THCV\uff09\uff1b\u30a8\u30ad\u30bd\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff08\u30a8\u30ad\u30bd-THC\uff09\uff1b9\uff08S\uff09-\u30d8\u30ad\u30b5\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff089\uff08S\uff09-HHC\uff09\uff1b\u30ab\u30f3\u30ca\u30d3\u30b7\u30af\u30ed\u30fc\u30eb\uff08CBL\uff09\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\uff1b 9(R)-\u30d8\u30ad\u30b5\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb(9(R)-HHC)\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff08CBN\uff09\uff1b9(S)-\u03946a,10a-THC\uff08\u039410-THC\uff09\uff1b\u30ab\u30f3\u30ca\u30d3\u30af\u30ed\u30e1\u30f3\uff08CBC\uff09\uff1b\u304a\u3088\u3073\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\u9178A\uff08THCA-A\uff09\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u3057\u3001\u958b\u767a\u3057\u305f\u5206\u6790\u65b9\u6cd5\u3067\u8a55\u4fa1\u3057\u305f\u3068\u3053\u308d\u3001\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3055\u308c\u305f\u5168\u3066\u306e\u5316\u5408\u7269\u306f\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304b\u3089\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u7279\u306b\u3001CBL\u306f\u03949-THC\u3068\u540c\u3058MRM\u30a6\u30a3\u30f3\u30c9\u30a6\u3067\u6eb6\u51fa\u3057\u307e\u3059\u304c\u3001\u4fdd\u6301\u6642\u9593\u306b\u660e\u78ba\u306a\u5dee\u304c\u3042\u308b\u305f\u3081\uff0811.16\u5206\u306811.40\u5206\uff09\u3001\u8aa4\u540c\u5b9a\u306e\u30ea\u30b9\u30af\u306f\u6975\u3081\u3066\u4f4e\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4ee5\u4e0a\u306e\u7d50\u679c\u304b\u3089\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3053\u308c\u3089\u985e\u4f3c\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306b\u3088\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3078\u306e\u5e72\u6e09\u306f\u8a8d\u3081\u3089\u308c\u305a\u3001\u9ad8\u3044\u9078\u629e\u6027\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 5<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> 12\u7a2e\u985e\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u304b\u3089\u306e\u03948\/9-THC\u7570\u6027\u4f53\u3068\u4ee3\u8b1d\u7269\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0827.png\" alt=\"\u03949-THC; \u03948-THC; Metabolites and 12 Structurally Similar Cannabinoids on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0827<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBDV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24274-48-4\/CBDV\" target=\"_blank\" rel=\"noopener\">CBDV<\/a><\/td><td class=\"oth\">3.22<\/td><td class=\"oth\">286.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">122.9<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">4.94<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">4.98<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13956-29-1\/CBD\" target=\"_blank\" rel=\"noopener\">CBD<\/a><\/td><td class=\"oth\">6.20<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for THCV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/31262-37-0\/THCV\" target=\"_blank\" rel=\"noopener\">THCV<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">286.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">122.9<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBG\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/25654-31-3\/CBG\" target=\"_blank\" rel=\"noopener\">CBG<\/a><\/td><td class=\"oth\">6.87<\/td><td class=\"oth\">317.0<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">123.0<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for exo-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27179-28-8\/exo-THC\" target=\"_blank\" rel=\"noopener\">exo-THC<\/a><\/td><td class=\"oth\">9.88<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">10.80<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9(S)-HHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36403-91-5\/9(S)-HHC\" target=\"_blank\" rel=\"noopener\">9(S)-HHC<\/a><\/td><td class=\"oth\">11.05<\/td><td class=\"oth\">317.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.1<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">11.16<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBL\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21366-63-2\/CBL\" target=\"_blank\" rel=\"noopener\">CBL<\/a><\/td><td class=\"oth\">11.40<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9(R)-HHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36403-90-4\/9(R)-HHC\" target=\"_blank\" rel=\"noopener\">9(R)-HHC<\/a><\/td><td class=\"oth\">11.85<\/td><td class=\"oth\">317.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.1<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBN\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/521-35-7\/CBN\" target=\"_blank\" rel=\"noopener\">CBN<\/a><\/td><td class=\"oth\">12.82<\/td><td class=\"oth\">311.1<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">293.2<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u039410-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95588-87-7\/\u039410-THC\" target=\"_blank\" rel=\"noopener\">\u039410-THC<\/a><\/td><td class=\"oth\">13.05<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">259.2<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for CBC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20675-51-8\/CBC\" target=\"_blank\" rel=\"noopener\">CBC<\/a><\/td><td class=\"oth\">13.96<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for THCA-A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23978-85-0\/THCA-A\" target=\"_blank\" rel=\"noopener\">THCA-A<\/a><\/td><td class=\"oth\">14.08<\/td><td class=\"oth\">359.3<\/td><td class=\"oth\">341.2<\/td><td class=\"oth\">219.0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>34132<\/li><li>34111<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>THC Isomers<\/li><li>cannabinoids<\/li><li>interferences<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0827.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306e\u5229\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0d\u6d3b\u6027\u51e6\u7406\u3055\u308c\u305fHPLC\u30ab\u30e9\u30e0\u306f\u5f93\u6765\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u306b\u6bd4\u3079\u3066\u591a\u304f\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002Restek\u306e\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306b\u306f\u3001\u30ab\u30e9\u30e0\u5185\u90e8\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u8868\u9762\u306b\u9ad8\u5ea6\u306a\u4e0d\u6d3b\u6027\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u3063\u3066\u3001\u91d1\u5c5e\u8868\u9762\u5168\u4f53\u306b\u5e83\u304f\u5206\u6790\u6210\u5206\u304c\u5438\u7740\u305b\u305a\u3001\u30ad\u30ec\u30fc\u30c8\u5316\u304c\u5927\u5e45\u306b\u6291\u5236\u3055\u308c\u307e\u3059\u3002\u9178\u6027\u5316\u5408\u7269\u306f\u30ad\u30ec\u30fc\u30c8\u5316\u3057\u3084\u3059\u3044\u305f\u3081\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u60aa\u5316\u3001\u691c\u51fa\u611f\u5ea6\u4f4e\u4e0b\u306e\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u304c\u3001Restek\u306e\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u306e\u6539\u5584\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u5b9f\u969b\u306e\u6bd4\u8f03\u8a66\u9a13\u3067\u306f\u3001Raptor FluoroPhenyl\u30ab\u30e9\u30e0\uff08\u5f93\u6765\u578b\uff09\u3068Raptor\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u5206\u6790\u3092\u884c\u3063\u305f\u3068\u3053\u308d\uff08<strong>Figure 6<\/strong>\u53c2\u7167\uff09\u3001\u89aa\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u306f\u4e21\u30ab\u30e9\u30e0\u9593\u3067\u5927\u304d\u306a\u9055\u3044\u306f\u898b\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u5316\u5408\u7269\u3084\u30ab\u30eb\u30dc\u30ad\u30b7\u5316\u5408\u7269\u3067\u306f\u3001\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u660e\u3089\u304b\u306b\u5897\u52a0\u3057\u3001\u691c\u51fa\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u30a4\u30ca\u30fc\u30c8HPLC\u30ab\u30e9\u30e0\u306f\u3001\u5f93\u6765\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u3067\u306f\u56f0\u96e3\u3060\u3063\u305f\u5206\u6790\u6210\u5206\uff08\u30d2\u30c9\u30ed\u30ad\u30b7\u304a\u3088\u3073\u30ab\u30eb\u30dc\u30ad\u30b7\uff09\u306e\u5206\u6790\u3092\u53ef\u80fd\u306b\u3057\u3001\u30e9\u30dc\u306e\u5206\u6790\u7cbe\u5ea6\u3068\u52b9\u7387\u3092\u5927\u304d\u304f\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> \u03949-THC\u3001\u03948-THC\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306b\u95a2\u3059\u308bRaptor FluoroPhenyl\u30ab\u30e9\u30e0\u3068Raptor\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306e\u6bd4\u8f03\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.png\" alt=\"Comparison of \u03949-THC; \u03948-THC; and Metabolites on Raptor FluoroPhenyl vs. Raptor Inert FluroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0829<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>cannabinoids<\/li><li>fluorophenyl<\/li><li>inert<\/li><li>isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6\u3000<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d2\u30c8\u5c3f\u4e2d\u304a\u3088\u3073\u5168\u8840\u4e2d\u306eTHC\u7570\u6027\u4f53\u3092\u4fe1\u983c\u6027\u9ad8\u304f\u6b63\u3057\u304f\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306e2\u3064\u306e\u9769\u65b0\u7684\u306a\u5206\u6790\u65b9\u6cd5\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5404\u30e1\u30bd\u30c3\u30c9\u306b\u304a\u3044\u3066\u3001\u5168\u8840\u304a\u3088\u3073\u5c3f\u306e\u4e21\u65b9\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u5bfe\u3057\u3066\u3001\u7c21\u4fbf\u306a\u6db2\u6db2\u62bd\u51fa\u6cd5\u3092\u9069\u7528\u3057\u307e\u3057\u305f[3,4]\u3002\u5c3f\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u3001THC\u306e\u30ab\u30eb\u30dc\u30ad\u30b7\u30eb\u4ee3\u8b1d\u7269\u3092\u7570\u6027\u4f53\u9593\u3067\u5b8c\u5168\u306b\u5206\u96e2\u53ef\u80fd\u306aLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u03948-THC\u3068\u03949-THC\u306a\u3069\u3001\u985e\u4f3c\u69cb\u9020\u3092\u6301\u3064\u7570\u6027\u4f53\u306e\u5b9a\u6027\u3092\u660e\u78ba\u306b\u884c\u3044\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u5831\u544a\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u6b21\u306b\u3001\u5168\u8840\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3067\u306f\u3001\u4e8b\u4ef6\u767a\u751f\u6642\u306e\u88ab\u9a13\u8005\u306e\u4e2d\u6bd2\u72b6\u614b\u8a55\u4fa1\u3092\u76ee\u7684\u3068\u3057\u3066\u3001\u89aa\u5316\u5408\u7269\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269\u3001\u30ab\u30eb\u30dc\u30ad\u30b7\u30eb\u4ee3\u8b1d\u7269\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u65b9\u6cd5\u3092\u69cb\u7bc9\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u624b\u6cd5\u306f\u3001\u9ad8\u901f\u3067\u5805\u7262\u304b\u3064\u9ad8\u611f\u5ea6\u3067\u3042\u308b\u3053\u3068\u3082\u78ba\u8a8d\u3055\u308c\u3066\u304a\u308a\u3001\u4e8b\u4ef6\u767a\u751f\u6642\u306e\u6b63\u78ba\u306a\u8a3a\u65ad\u3084\u03948-THC\u3068\u03949-THC\u306e\u6442\u53d6\u8b58\u5225\u306b\u5f93\u4e8b\u3057\u3066\u3044\u308b\u81e8\u5e8a\u691c\u67fb\u30e9\u30dc\u3084\u6bd2\u7269\u691c\u67fb\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u6975\u3081\u3066\u6709\u7528\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u306a\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>E.L. Karschner, M.J. Swortwood-Gates, M.A. Huestis, Identifying and Quantifying Cannabinoids in Biological Matrices in the Medical and Legal Cannabis Era. Clinical Chemistry 66 (7) (2020) 888-914.&nbsp;<a href=\"https:\/\/academic.oup.com\/clinchem\/article\/66\/7\/888\/5867829?login=false\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/academic.oup.com\/clinchem\/article\/66\/7\/888\/5867829?login=false<\/a><\/li>\n\n\n\n<li>Mayo Clinic Laboratories, Marijuana: Comprehensive urine drug testing to confirm and monitor use &nbsp;<a href=\"https:\/\/www.mayocliniclabs.com\/test-catalog\/drug-book\/specific-drug-groups\/marijuana\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.mayocliniclabs.com\/test-catalog\/drug-book\/specific-drug-groups\/marijuana<\/a> (Accessed April 1, 2025).<\/li>\n\n\n\n<li>Virginia Department of Forensic Science, Toxicology Procedures Manual, 2024, <a href=\"https:\/\/dfs.virginia.gov\/wp-content\/uploads\/220-D100%20Toxicology%20Procedures%20Manual-2816-68516b23b1d7e.pdf\" data-type=\"link\" data-id=\"https:\/\/dfs.virginia.gov\/wp-content\/uploads\/220-D100%20Toxicology%20Procedures%20Manual-2816-68516b23b1d7e.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/dfs.virginia.gov\/wp-content\/uploads\/220-D100%20Toxicology%20Procedures%20Manual-2816-67ec03f17b822.pdf\u00a0<\/a><\/li>\n\n\n\n<li>N.B. Tiscione, R . Miller, X. Shan, J. Sprague, D.T. Yeatman. An efficient, robust method for the determination of cannabinoids in whole blood by LC-MS-MS. J Anal. Toxicol., 40 (2016) (8) 639-648. <a href=\"https:\/\/doi.org\/10.1093\/jat\/bkw063\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1093\/jat\/bkw063<\/a><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u7814\u7a76\u7528\u9014\u306e\u307f\u306b\u958b\u767a\u3055\u308c\u3066\u304a\u308a\u3001\u8a3a\u65ad\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3055\u3089\u306a\u308b\u691c\u8a3c\u304c\u5fc5\u8981\u3067\u3059\u3002<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A1E-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                \u30ab\u30bf\u30ed\u30b0No. 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 8-Tetrahydrocannabinol (Delta 8-THC) Standard, 1000 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                \u30ab\u30bf\u30ed\u30b0No. 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u30c7\u30eb\u30bf9-\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb (Delta 9-THC) \u6a19\u6e96\u6db2 1000 \u00b5g\/m, 1 mL\/ampul \uff5c\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                \u30ab\u30bf\u30ed\u30b0No. 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carboxy-Delta-9-THC Standard, 100 \u00b5g\/mL, methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5168\u8840\u304a\u3088\u3073\u5c3f\u4e2d\u306eTHC\u7570\u6027\u4f53\u3068\u4ee3\u8b1d\u7269\u3092\u9ad8\u611f\u5ea6\u30fb\u9ad8\u7cbe\u5ea6\u3067\u6e2c\u5b9a\u3059\u308b\u65b0\u3057\u3044LC-MS\/MS\u5206\u6790\u6cd5\u3092\u7d39\u4ecb\u3002\u7c21\u4fbf\u306a\u6db2\u6db2\u62bd\u51fa\u3068\u512a\u308c\u305f\u5206\u96e2\u80fd\u3067\u3001\u03948-THC\u3068\u03949-THC\u306e\u8b58\u5225\u3084\u4e2d\u6bd2\u8a3a\u65ad\u3092\u30b5\u30dd\u30fc\u30c8\u3002\u81e8\u5e8a\u691c\u67fb\u30fb\u6bd2\u7269\u691c\u67fb\u30e9\u30dc\u306b\u6700\u9069\u306a\u6700\u65b0\u30e1\u30bd\u30c3\u30c9\u3067\u3059\u3002<\/p>\n","protected":false},"author":13,"featured_media":6426,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2299],"ppma_author":[432,579],"class_list":["post-43362","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAN4420-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."},{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43362","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43362"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43362\/revisions"}],"predecessor-version":[{"id":69131,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43362\/revisions\/69131"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6426"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43362"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43362"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43362"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43362"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43362"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43362"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43362"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43362"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}