{"id":43374,"date":"2023-12-18T00:00:00","date_gmt":"2023-12-18T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/validation-of-a-liquid-chromatography-coupled-to-mass-spectrometry-method-for-glyphosate-and-aminomethylphosphonic-acid-in-urine-for-human-biomonitoring-using-combined-hybrid-anion-exchange-and-hydrop\/"},"modified":"2025-11-26T20:14:32","modified_gmt":"2025-11-26T20:14:32","slug":"validation-of-a-liquid-chromatography-coupled-to-mass-spectrometry-method-for-glyphosate-and-aminomethylphosphonic-acid-in-urine-for-human-biomonitoring-using-combined-hybrid-anion-exchange-and-hydrop","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles\/cfot4205\/validation-of-a-liquid-chromatography-coupled-to-mass-spectrometry-method-for-glyphosate-and-aminomethylphosphonic-acid-in-urine-for-human-biomonitoring-using-combined-hybrid-anion-exchange-and-hydrop","title":{"rendered":"Validation of a Liquid Chromatography Coupled to Mass Spectrometry Method for Glyphosate and Aminomethylphosphonic Acid in Urine for Human Biomonitoring Using Combined Hybrid Anion-Exchange and Hydrophilic Interaction Liquid Chromatography"},"content":{"rendered":"\n<p><strong>Author(s):<\/strong> Elisa Polledri<sup>1<\/sup>, Rosa Mercadante<sup>1<\/sup>, Silvia Fustinoni<sup>1,2<\/sup><br>1. EPIGET\u2014Epidemiology, Epigenetics, and Toxicology Lab, Department of Clinical Sciences and Community Health, Universit\u00e0 degli Studi di Milano, 20122 Milano, Italy, 2. Environmental and Industrial Toxicology, Fondazione IRCCS Ca\u2019 Granda Ospedale Maggiore Policlinico, 20122 Milano, Italy<\/p>\n\n\n\n<p><strong>Published By:<\/strong> Separations&nbsp;<\/p>\n\n\n\n<p><strong>Issue:<\/strong> 10(11), 576<\/p>\n\n\n\n<p><strong>Year of Publication:<\/strong> 2023<\/p>\n\n\n\n<p><strong>Link:<\/strong> <a href=\"https:\/\/doi.org\/10.3390\/separations10110576\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.3390\/separations10110576<\/a>&nbsp;<\/p>\n\n\n\n<p><strong>Abstract:<\/strong> Glyphosate-based herbicides are the most widely used pesticides in the world; however, the toxicity of glyphosate (GlyP) toward humans, especially its carcinogenicity, is controversial. The aim of this work was to validate a rapid assay for measuring GlyP and its metabolite aminomethylphosphonic acid (AMPA) in urine for human biomonitoring. The analytes were purified via solid-phase extraction in the presence of isotopically labeled internal standards. An LC-MS\/MS assay was developed using a column with a novel hybrid stationary phase combined with anion exchange and hydrophilic interaction liquid chromatography. Detection and quantification were performed using negative electrospray ionization in a hybrid triple quadrupole\/linear ion trap mass spectrometer. The retention times for AMPA and GlyP were 1.44 and 7.24 min, respectively. Calibration curves showed a linear dynamic range of up to 40 \u00b5g\/L, inter- and intra-run precisions &lt;7.5%, and accuracies within 10% of the theoretical concentrations. The limits of quantification were 0.1 \u00b5g\/L and 0.5 \u00b5g\/L for GlyP and AMPA, respectively. The matrix effect bias was controlled using internal standards. Successful participation in external quality assurance exercises strengthens the validity of the method. The assay was applied to the measurement of GlyP and AMPA in the urine of 9 urban residents, 26 rural residents, and 12 agricultural workers; while AMPA was mostly not quantifiable, the median GlyP values were 0.1 and 0.34 \u00b5g\/L in rural residents and workers, respectively. The assay is useful to assess GlyP and AMPA in human urine following different exposure scenarios.<\/p>\n\n\n\n<p><strong>Acknowledgment(s):<\/strong> This analysis features a Restek Polar X LC column (cat.# 9311A52), which was selected after the authors tested multiple other LC columns.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">                                Catalog No. 9311A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 50 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Glyphosate-based herbicides are the most widely used pesticides in the world; however, the toxicity of glyphosate (GlyP) toward humans, especially its carcinogenicity, is controversial. The aim of this work was to validate a rapid assay for measuring GlyP and its metabolite aminomethylphosphonic acid (AMPA) in urine for human biomonitoring.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[7],"tags":[],"industries-application":[2153,2156],"post-badge":[],"resource-type":[568],"product-library":[2391,2373],"resource-technique":[2299,2302],"ppma_author":[678,741,748],"class_list":["post-43374","post","type-post","status-publish","format-standard","hentry","category-articles","industries-application-clinical","industries-application-clinical-toxicology","resource-type-third-party-peer-reviewed-publications","product-library-lc-columns","product-library-liquid-chromatography-products","resource-technique-liquid-chromatography","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2153,"label":"Clinical"},{"value":2156,"label":"Clinical Toxicology"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":464,"filter":"raw","cat_ID":7,"category_count":464,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":678,"user_id":0,"is_guest":1,"slug":"elisa-polledri","display_name":"Elisa Polledri","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":741,"user_id":0,"is_guest":1,"slug":"rosa-mercadante","display_name":"Rosa Mercadante","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":748,"user_id":0,"is_guest":1,"slug":"silvia-fustinoni","display_name":"Silvia Fustinoni","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43374","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43374"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43374\/revisions"}],"predecessor-version":[{"id":59750,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43374\/revisions\/59750"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43374"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43374"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43374"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43374"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43374"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43374"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43374"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43374"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43374"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}