{"id":43397,"date":"2020-10-20T14:30:00","date_gmt":"2020-10-20T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/reliable-low-level-analysis-of-glycols-in-water-using-split-injection-japan\/"},"modified":"2026-01-14T16:56:32","modified_gmt":"2026-01-14T16:56:32","slug":"reliable-low-level-analysis-of-glycols-in-water-using-split-injection-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan2873-ja\/reliable-low-level-analysis-of-glycols-in-water-using-split-injection-japan","title":{"rendered":"\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u3088\u308b\u6c34\u4e2d\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u7528\u3044\u305f\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u4f4e\u6fc3\u5ea6\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u3067\u306f\u3001\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u5f97\u308b\u306e\u304c\u56f0\u96e3\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u4e3b\u306b\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38\u3001\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u3068\u3044\u3063\u305f\u3053\u3068\u306b\u8d77\u56e0\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u793a\u3059\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u56de\u907f\u3057\u3001\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u7d50\u679c\u3092\u78ba\u5b9f\u306b\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u8010\u4e45\u6027\u8a66\u9a13\u3067\u306f\u3001Rtx-Wax\u30ab\u30e9\u30e0\u304c600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u751f\u6210\u3059\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306f\u3001\u74b0\u5883\u3001\u98df\u54c1\u5b89\u5168\u3001\u304a\u3088\u3073\u5316\u5b66\u5b9f\u9a13\u5ba4\u3067\u304a\u3053\u306a\u308f\u308c\u308b\u4e00\u822c\u7684\u306a\u8a66\u9a13\u3067\u3059\u3002\u6c34\u306e\u51dd\u56fa\u70b9\u3092\u52b9\u679c\u7684\u306b\u4e0b\u3052\u308b\u305f\u3081\u3001 \u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u4e21\u65b9\u304c\u591a\u304f\u306e\u7523\u696d\u3067\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u4e21\u8005\u306b\u306f\u660e\u3089\u304b\u306a\u9055\u3044\u304c\u3042\u308a\u307e\u3059\u3002\u3059\u306a\u308f\u3061\u3001\u6442\u53d6\u3057\u305f\u5834\u5408\u306b\u306f\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304c\u308f\u305a\u304b2\uff5e4\u30aa\u30f3\u30b9(57\uff5e113g)\u3067\u751f\u547d\u306b\u304b\u304b\u308f\u308b\u304a\u305d\u308c\u304c\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u98df\u54c1\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u305d\u306e\u6bd2\u6027\u3068\u66b4\u9732\u306e\u53ef\u80fd\u6027\u304c\u5e83\u7bc4\u56f2\u306b\u308f\u305f\u308b\u305f\u3081\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u4f4e\u6fc3\u5ea6\u3067\u306e\u5b9a\u91cf\u304c\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30ea\u30b3\u30fc\u30eb\u3078\u306e\u66b4\u9732\u306f\u3001\u81ea\u52d5\u8eca\u306e\u4e0d\u51cd\u6db2\u3001\u822a\u7a7a\u6a5f\u306e\u9664\u6c37\u6db2\u3001\u304a\u3088\u3073\u6c34\u5727\u7834\u7815\u6db2\u306b\u3088\u308b\u6c34\u306e\u74b0\u5883\u6c5a\u67d3\u3092\u901a\u3057\u3066\u8d77\u3053\u308a\u5f97\u307e\u3059\u3002\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u30011926\u5e74\u306b\u521d\u3081\u3066\u81ea\u52d5\u8eca\u4e0d\u51cd\u6db2\u306b\u4f7f\u7528\u3055\u308c[1]\u3001\u4f9d\u7136\u3068\u3057\u3066\u4e3b\u8981\u6210\u5206\u3067\u3059\u3002\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u822a\u7a7a\u6a5f\u9664\u6c37\u306f\u30011950\u5e74\u4ee3\u306b\u4e00\u822c\u7684\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5316\u5b66\u7269\u8cea\u306f\u3001\u5869\u304c\u7740\u9678\u88c5\u7f6e\u306e\u90e8\u54c1\u3092\u8150\u98df\u3059\u308b\u305f\u3081\u3001\u5869\u306e\u4ee3\u66ff\u3068\u3057\u3066\u6ed1\u8d70\u8def\u3067\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059[2]\u3002\u6c34\u5727\u7834\u7815\u306f\u3001\u30b0\u30ea\u30b3\u30fc\u30eb\u3078\u306e\u8457\u3057\u3044\u66b4\u9732\u3092\u3082\u305f\u3089\u3057\u5f97\u308b\u5225\u306e\u7523\u696d\u7528\u9014\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u3067\u306f\u3001\u52a0\u5727\u6d41\u4f53\u3068\u7802\u3082\u3057\u304f\u306f\u4ed6\u306e\u56fa\u4f53(\u30d7\u30ed\u30d1\u30f3\u30c8)\u3092\u30ac\u30b9\u6398\u524a\u306b\u4f7f\u7528\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u304b\u3064\u3066\u4e0d\u53ef\u80fd\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u305f\u5834\u6240\u304b\u3089\u306e\u30ac\u30b9\u63a1\u6398\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u6c34\u5727\u7834\u7815\u6db2\u306e\u4e00\u822c\u7684\u306a\u6210\u5206\u3067\u3042\u308a\u3001\u6eb6\u6db2\u306e\u5b89\u5b9a\u5316\u3068\u4e73\u5316\u306e\u9632\u6b62\u306b\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059[3]\u3002\u30b0\u30ea\u30b3\u30fc\u30eb\u985e\u3084\u6c34\u5727\u7834\u7815\u306b\u4f7f\u7528\u3055\u308c\u308b\u4ed6\u306e\u5316\u5408\u7269\u306b\u3088\u308b\u6c34\u8cea\u6c5a\u67d3\u306e\u61f8\u5ff5\u304b\u3089\u3001\u73fe\u5728\u30a2\u30e1\u30ea\u30ab\u5408\u8846\u56fd\u306e14\u306e\u5dde\u3067\u306f\u3053\u308c\u3089\u306e\u5316\u5b66\u7269\u8cea\u306e\u958b\u793a\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u6c34\u6eb6\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u30d1\u30fc\u30b8\u30a2\u30f3\u30c9\u30c8\u30e9\u30c3\u30d7\u6cd5\u3084\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\u3067\u306f\u5bb9\u6613\u306b\u6fc3\u7e2e\u3055\u308c\u307e\u305b\u3093\u3002\u5f93\u3063\u3066\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306b\u3088\u308b\u6c34\u6ce8\u5165\u306f\u3001\u6700\u3082\u3088\u304f\u7528\u3044\u3089\u308c\u308b\u8a66\u6599\u5c0e\u5165\u6cd5\u3067\u3059\u3002\u3057\u304b\u3057\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u3088\u308b\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u985e\u306e\u5206\u6790\u306f\u96e3\u3057\u304f\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38\u304a\u3088\u3073\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u306b\u3088\u308a\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u91cf\u304c\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf\u3092\u8d85\u3048\u308b\u3068\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u767a\u751f\u3057\u307e\u3059\u3002\u84b8\u6c17\u306f\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u9006\u6d41\u3057\u3001\u305d\u306e\u7d50\u679c\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u52d5\u304c\u4e0d\u5341\u5206\u306b\u306a\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30d4\u30fc\u30af\u306f\u5225\u306e\u539f\u56e0\u306b\u3088\u308b\u3082\u306e\u3067\u3059\u3002\u3053\u308c\u306f\u30b0\u30ea\u30b3\u30fc\u30eb\u304c\u30ab\u30e9\u30e0\u5165\u53e3\u3067\u72ed\u3044\u30d0\u30f3\u30c9\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3055\u308c\u305a\u306b\u3001\u30ab\u30e9\u30e0\u306e\u5185\u58c1\u306b\u5206\u6563\u3057\u305f\u51dd\u7e2e\u6c34\u306b\u70b9\u5728\u3059\u308b\u5834\u5408\u306b\u751f\u3058\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30d4\u30fc\u30af\u306f\u30dd\u30ea\u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3(PDMS)\u76f8\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u304a\u3053\u306a\u3046\u5834\u5408\u306b\u6700\u3082\u9855\u8457\u306b\u73fe\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u554f\u984c\u306f\u3001\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u5fc5\u8981\u306a0.5~10 ppm\u306e\u691c\u51fa\u9650\u754c\u3092\u59a8\u3052\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u7528\u3044\u305f\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306f\u3088\u308a\u826f\u3044\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3059\u3002\u30ab\u30e9\u30e0\u3078\u306e\u8fc5\u901f\u304b\u3064\u5b89\u5b9a\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u79fb\u52d5\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u30ab\u30e9\u30e0\u3078\u5165\u308b\u6c34\u306e\u91cf\u3092\u6e1b\u3089\u3057\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u554f\u984c\u3060\u3051\u3067\u306a\u304f\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3082\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u304c\u4f4e\u6fc3\u5ea6\u5206\u6790\u306e\u6539\u5584\u306b\u3064\u306a\u304c\u308b\u3068\u3044\u3046\u306e\u306f\u30a4\u30e1\u30fc\u30b8\u3057\u306b\u304f\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u304c\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u518d\u73fe\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u3067\u4f4e\u6fc3\u5ea6\u3067\u3082\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u56fa\u6709\u306e\u9078\u629e\u6027\u3092\u6709\u3057\u3001\u9ad8\u6975\u6027\u6eb6\u5a92\u306e\u6ce8\u5165\u306b\u9069\u3057\u3066\u3044\u308b\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PEG\uff09\u30ab\u30e9\u30e0\u3068\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u306e\u7d44\u307f\u5408\u308f\u305b\u306f\u3001\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u985e\u3092\u5206\u6790\u3059\u308b\u4e0a\u3067\u6700\u826f\u306e\u65b9\u6cd5\u3067\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u4f4e\u6fc3\u5ea6\u3067\u3082\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u7d50\u679c\u3092\u5b89\u5b9a\u3057\u3066\u5f97\u3089\u308c\u308b\u5206\u6790\u6761\u4ef6\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u66f4\u306b\u3001\u3053\u306e\u5206\u6790\u3067\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u308bRtx-Wax\u30ab\u30e9\u30e0\u3068Stabilwax\u30ab\u30e9\u30e0\u306e\u8010\u4e45\u6027\u80fd\u3092\u6bd4\u8f03\u3057\u3001\u3069\u3061\u3089\u306ePEG\u30ab\u30e9\u30e0\u304c\u6700\u3082\u9069\u3057\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u96e2\u30ab\u30e9\u30e0\u3068\u5206\u6790\u6761\u4ef6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u985e\u3092\u5206\u6790\u3059\u308b\u306b\u3042\u305f\u308a\u3001Rtx-Wax (cat.# 12455) \u3068 Stabilwax (cat.# 10655) \u306e\u6027\u80fd\u3092\u4e0b\u8a18\u306e\u6761\u4ef6\u3067\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u7dcf\u5408\u7684\u306a\u793e\u5185\u3067\u306e\u6761\u4ef6\u691c\u8a0e\u3092\u91cd\u306d\u3001\u5bfe\u79f0\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3092\u78ba\u5b9f\u306b\u5f97\u3089\u308c\u308b\u6761\u4ef6\u3092\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u4eca\u56de\u306e\u5b9f\u9a13\u3067\u306f\u3001\u30a6\u30fc\u30eb\u5165\u308a\u30e9\u30a4\u30ca\u30fc\u3092\u7528\u3044\u305f1\u03bcl\u300150\uff1a1\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u3088\u308a\u3001\u6ce8\u5165\u53e3\u3067\u306e\u554f\u984c\u304c\u53d6\u308a\u9664\u304b\u308c\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306f\u4f4e\u6e1b\u3057\u3001\u518d\u73fe\u6027\u304c\u3088\u304f\u306a\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u30a6\u30fc\u30eb\u5165\u308a\u5185\u5f844.0mm\u30e9\u30a4\u30ca\u30fc\u306e\u5229\u7528\u306f\u826f\u597d\u306a\u518d\u73fe\u6027\u3092\u5f97\u308b\u305f\u3081\u306b\u91cd\u8981\u3067\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30a6\u30fc\u30eb\u306b\u3088\u308a\u30b5\u30f3\u30d7\u30eb\u304c\u8fc5\u901f\u304b\u3064\u5b8c\u5168\u306b\u6c17\u5316\u3067\u304d\u308b\u304b\u3089\u3067\u3059\u3002\u30ab\u30e9\u30e0\u306e\u8010\u4e45\u6027\u3092\u8a66\u9a13\u3059\u308b\u306b\u306f\u3088\u308a\u53b3\u3057\u3044\u6761\u4ef6\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u306e\u6761\u4ef6\u3092\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306b\u5909\u66f4\u3057\u3066\u6c34\u306e\u6ce8\u5165\u306b\u4f7f\u7528\u3057\u307e\u3057\u305f\uff08\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306b\u306f\u4f7f\u7528\u3057\u3066\u3044\u307e\u305b\u3093\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\uff1a<\/td><td>30 m, 0.53 mm ID, 1.0 \u03bcm<\/td><\/tr><tr><td>\u6ce8\u5165\uff1a<\/td><td>1 \u03bcL, \u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4 50:1 \uff08\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u3001\u9ad8\u901f\u6ce8\u5165\uff09<\/td><\/tr><tr><td>\u30e9\u30a4\u30ca\u30fc\uff1a<\/td><td>Premium 4.0 mm ID Precision inlet liner w\/wool (cat.# 23305.1), \u6ce8\uff09\u3053\u306e\u88fd\u54c1\u306e\u5f8c\u7d99\u54c1\u306f Topaz 4.0 mm ID Precision inlet liner w\/wool (cat.# 23305)\u3067\u3059\u3002<\/td><\/tr><tr><td>\u6ce8\u5165\u53e3\u6e29\u5ea6\uff1a<\/td><td>250 \u00b0C<\/td><\/tr><tr><td>\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\uff1a<\/td><td>40 \u00b0C (hold 1.0 min) to 250 \u00b0C at 30 \u00b0C\/min<\/td><\/tr><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\uff1a<\/td><td>He, 4 psi (constant flow)<\/td><\/tr><tr><td>\u7dda\u901f\u5ea6\uff1a<\/td><td>40 cm\/sec<\/td><\/tr><tr><td>\u691c\u51fa\u5668\uff1a<\/td><td>FID @ 250 \u00b0C<\/td><\/tr><tr><td>\u30e1\u30fc\u30af\u30a2\u30c3\u30d7\u30ac\u30b9\u6d41\u91cf\uff1a<\/td><td>45 mL\/min<\/td><\/tr><tr><td>\u30e1\u30fc\u30af\u30a2\u30c3\u30d7\u30ac\u30b9\u7a2e\u985e\uff1a<\/td><td>N<sub>2<\/sub><\/td><\/tr><tr><td>\u6c34\u7d20\u6d41\u91cf\uff1a<\/td><td>40 mL\/min<\/td><\/tr><tr><td>\u30a8\u30a2\u6d41\u91cf\uff1a<\/td><td>450 mL\/min<\/td><\/tr><tr><td>Data Rate:<\/td><td>20 Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u76f4\u7dda\u6027\u8a55\u4fa1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u691c\u91cf\u7dda\u7528\u6a19\u6e96\u6db2\u306f\u3001\u6df7\u5408\u30b0\u30ea\u30b3\u30fc\u30eb\u6a19\u6e96\u6db2 (cat.# 30471) \u306b\u30e1\u30bf\u30ce\u30fc\u30eb\uff1a\u6c34\uff0810\uff1a90\uff09\u52a0\u3048\u3066\u8abf\u88fd\u3057\u307e\u3057\u305f\u30022-\u30d6\u30c8\u30ad\u30b7\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5404\u6eb6\u6db2\u306b\u6700\u7d42\u6fc3\u5ea6500 ppm(\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf10 ppm)\u3068\u306a\u308b\u3088\u3046\u306b\u6dfb\u52a0\u3057\u3001\u5185\u90e8\u6a19\u6e96\u3068\u3057\u307e\u3057\u305f\u3002\u691c\u91cf\u7dda\u7bc4\u56f2\u304c0.5-100ng\u306e\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf\u3068\u306a\u308b\u3088\u3046\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3092\u7528\u3044\u3066\u5206\u6790\u3057\u307e\u3057\u305f\u3002\u6700\u521d\u306b\u3001\u672a\u4f7f\u7528\u306e\u65b0\u3057\u3044Rtx-Wax\u304a\u3088\u3073Stabilwax\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u691c\u91cf\u7dda\u3092\u78ba\u7acb\u3057\u3001\u521d\u671f\u306e\u76f4\u7dda\u6027\u3092\u78ba\u8a8d\u3057\u3001\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u306e\u52a3\u5316\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u306b\u3088\u308b\u8010\u4e45\u6027\u8a66\u9a13\u5f8c\u306b\u518d\u5ea6\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u3001\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u78ba\u8a8d\u3092\u304a\u3053\u306a\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u8010\u4e45\u6027\u8a66\u9a13<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">3\u3064\u306e\u7570\u306a\u308b\u30ed\u30c3\u30c8\u306eRtx-Wax\u30ab\u30e9\u30e0\u30682\u3064\u306e\u7570\u306a\u308b\u30ed\u30c3\u30c8\u306eStabilwax\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u3001\u8010\u4e45\u6027\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3001\u3069\u3061\u3089\u304c\u6c34\u6ce8\u5165\u3092\u7e70\u308a\u8fd4\u3057\u3066\u3082\u8010\u4e45\u6027\u306b\u512a\u308c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u7dad\u6301\u3067\u304d\u308b\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002\u5b9f\u9a13\u3067\u306f\u3001\u6c34\u309210\u56de\uff081 \u03bcL\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\uff09\u6ce8\u5165\u3057\u305f\u5f8c\u306b\u300150 \u03bcg\/mL\u30b0\u30ea\u30b3\u30fc\u30eb\u6a19\u6e96\u6db2\uff0850\uff1a1\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf1 ng\uff09\u3092\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002\u6c34\u306e\u6ce8\u5165\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30e2\u30fc\u30c9\u3067\u304a\u3053\u306a\u3046\u3053\u3068\u3067\u30ab\u30e9\u30e0\u3078\u306e\u6c34\u306e\u66b4\u9732\u3092\u6700\u5927\u306b\u3057\u3001\u3088\u308a\u53b3\u3057\u3044\u6761\u4ef6\u3068\u3057\u307e\u3057\u305f\u3002\u6a19\u6e96\u6db2\u306e\u6ce8\u5165\u306f\u3001\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u304a\u3044\u3066\u5b89\u5b9a\u3057\u3066\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u5f97\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u305f\u524d\u8ff0\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u30e2\u30fc\u30c9\u3067\u304a\u3053\u306a\u3044\u307e\u3057\u305f\u3002\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306f\u3001\u6c34\u6ce8\u516510\u56de\u3054\u3068\u306b\u8a55\u4fa1\u3057\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c0.50\u672a\u6e80\u306b\u306a\u308b\u304b\u3001\u307e\u305f\u306f\u6c34\u6ce8\u5165\u304c600\u56de\u306b\u9054\u3059\u308b\u307e\u3067\u3001\u540c\u69d8\u306e\u624b\u9806\u3092\u7e70\u308a\u8fd4\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8010\u4e45\u6027\u8a66\u9a13\u306b\u4f7f\u7528\u3057\u305f\u6a19\u6e96\u6db2\u306f\u3001\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u6df7\u5408\u30b0\u30ea\u30b3\u30fc\u30eb\u6a19\u6e96\u6db2 (cat.# 30471) \u3092\u30e1\u30bf\u30ce\u30fc\u30eb\uff1a\u6c34\uff0810:90\uff09\u306750\u03bcg\/mL\uff08ppm\uff09\u306b\u5e0c\u91c8\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u6a19\u6e96\u6db2\u3084\u30b5\u30f3\u30d7\u30eb\u309210\uff05\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u8abf\u88fd\u3059\u308b\u3053\u3068\u3067\u3001\u30d7\u30e9\u30f3\u30b8\u30e3\u30fc\u304c\u52d5\u304b\u306a\u304f\u306a\u308b\u306e\u3092\u9632\u6b62\u3067\u304d\u308b\u305f\u3081\u65e5\u5e38\u7684\u306a\u5206\u6790\u306b\u63a8\u5968\u3057\u307e\u3059\u30022-\u30d6\u30c8\u30ad\u30b7\u30a8\u30bf\u30ce\u30fc\u30eb\u306f\u5185\u90e8\u6a19\u6e96\u3068\u3057\u3066\u5404\u6eb6\u6db2\u306b500ppm\uff08\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf10ppm\uff09\u306b\u306a\u308b\u3088\u3046\u306b\u6dfb\u52a0\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u7528\u3044\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u30ab\u30e9\u30e0\u3078\u30b5\u30f3\u30d7\u30eb\u306f\u8fc5\u901f\u306b\u79fb\u52d5\u3057\u3001\u30ab\u30e9\u30e0\u5185\u3067\u72ed\u3044\u30b5\u30f3\u30d7\u30eb\u30d0\u30f3\u30c9\u304c\u5f62\u6210\u3055\u308c\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u306e\u5b89\u5b9a\u6027\u304c\u6539\u5584\u3055\u308c\u307e\u3059\u3002\u52a0\u3048\u3066\u3001\u6ce8\u5165\u53e3\u5185\u3067\u306e\u6c34\u306e\u91cf\u304c\u6e1b\u308a\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306e\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u4f7f\u7528\u3057\u305f50\uff1a1\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u3001\u6c34\u306e\u6c17\u5316\u4f53\u7a4d\u554f\u984c\u3092\u52b9\u679c\u7684\u306b\u9632\u3050\u3053\u3068\u304c\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3078\u5c0e\u5165\u3055\u308c\u308b\u30b5\u30f3\u30d7\u30eb\u91cf\u306f\u5927\u5e45\u306b\u6e1b\u5c11\u3057\u307e\u3057\u305f\u304c\u3001Rtx-Wax\u30ab\u30e9\u30e0\u3067\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\uff08<strong>Figure 1<\/strong>\u304a\u3088\u3073<strong>Figure 2<\/strong>\uff09\u5f8c\u3067\u3042\u3063\u3066\u3082\u3001\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u4e21\u65b9\u3067\u5341\u5206\u306a\u611f\u5ea6\u3068\u76f4\u7dda\u6027\u304c\u9054\u6210\u3055\u308c\u307e\u3057\u305f\u3002\u5bfe\u7167\u7684\u306bStabilwax\u30ab\u30e9\u30e0\u3067\u306f\u3001350\u56de\u306e\u6ce8\u5165\u5f8c\u306b\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c0.5\u672a\u6e80\u306b\u4f4e\u4e0b\u3057\u305f\u305f\u3081\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u306b\u76f4\u7dda\u6027\u3092\u9054\u6210\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf0.5-100 ng\uff09\u306b\u304a\u3044\u3066\u691c<br>\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"644\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-EVAN2873-01-1024x644.jpg\" alt=\"\" class=\"wp-image-19413\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-01-1024x644.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-01-300x189.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-01-768x483.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-01-1536x966.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf 0.5-100 ng\uff09\u306b\u304a\u3044\u3066\u691c\u91cf<br>\u7dda\u306e\u76f4\u7dda\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"644\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-EVAN2873-02-1024x644.jpg\" alt=\"\" class=\"wp-image-19419\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-02-1024x644.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-02-300x189.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-02-768x483.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-02-1536x966.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAN2873-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306e\u3088\u3046\u306b\u9ad8\u6e29\u3067\u6eb6\u51fa\u3059\u308b\u4f4e\u6fc3\u5ea6\u5316\u5408\u7269\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u306f\u5e38\u306b\u6f5c\u5728\u7684\u306a\u554f\u984c\u306b\u306a\u308a\u307e\u3059\u3002\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u4e21\u65b9\u3068\u3082\u3001\u6cb8\u70b9\u304c\u305d\u308c\u305e\u308c188\u2103\u3068197\u2103\u3068\u6bd4\u8f03\u7684\u9ad8\u304f\u3001\u9069\u5207\u306a\u6eb6\u51fa\u306b\u306fGC\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092200\u2103\u4ee5\u4e0a\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u74b0\u5883\u30b5\u30f3\u30d7\u30eb\u3067\u3088\u304f\u898b\u3089\u308c\u308b\u9ad8\u5206\u5b50\u91cf\u306e\u6c5a\u67d3\u7269\u8cea\u3092\u6eb6\u51fa\u3055\u305b\u308b\u305f\u3081\u306b\u306f240\u2103\u307e\u3067\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u4e0a\u3052\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u3053\u306e\u3088\u3046\u306a\u6e29\u5ea6\u306b\u304a\u3051\u308b\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u306f\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf10 ng\u4ee5\u4e0b\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u6b63\u78ba\u306a\u5206\u6790\u3092\u59a8\u3052\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u8010\u4e45\u6027\u8a66\u9a13\u306b\u304a\u3051\u308b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u76ee\u8996\u306b\u3088\u308b\u78ba\u8a8d\u3067\u306f\u3001Rtx-Wax\u304a\u3088\u3073Stabilwax\u30ab\u30e9\u30e0\u306e\u4e21\u65b9\u3067\u975e\u5e38\u306b\u30d6\u30ea\u30fc\u30c9\u304c\u4f4e\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rtx-Wax\u3068Stabiwax\u306e\u4e21\u65b9\u3067\u4f4e\u3044\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u304c\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306e\u65b9\u304c\u3001\u6c34\u6ce8\u5165\u306b\u5bfe\u3057\u3066\u306f\u308b\u304b\u306b\u9ad8\u3044\u8010\u4e45\u6027\u3092\u6709\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u8a66\u9a13\u3057\u305f3\u30ed\u30c3\u30c8\u306eRtx-Wax\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6c34\u6ce8\u5165600\u56de\u5f8c\u3067\u3082\u3001\u3044\u305a\u308c\u306e\u5316\u5408\u7269\u3082\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u306b\u5909\u5316\u306f\u306a\u304f\u3001\u512a\u308c\u305f\u6027\u80fd\u3092\u793a\u3057\u307e\u3057\u305f\uff08<strong>Figure 3<\/strong>\uff09\u3002\u5b9f\u969b\u3001\u8010\u4e45\u6027\u8a66\u9a13\u5f8c\u306e\u6700\u5f8c\u306b\u8a66\u9a13\u3057\u305fRtx-Wax\u30ab\u30e9\u30e0\u306f\u30011600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u826f\u597d\u306a\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3057\u305f\u3002\u5bfe\u7167\u7684\u306bStabilwax\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6c34\u6ce8\u5165100\u56de\u3067\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c\u60aa\u304f\u306a\u308a\u59cb\u3081\u3001350\u56de\u306e\u6ce8\u5165\u5f8c\u3067\u306f\u8457\u3057\u304f\u52a3\u5316\u3057\uff08<strong>Figure 4<\/strong>\uff09\u3001\u30ab\u30e9\u30e0\u30c8\u30ea\u30df\u30f3\u30b0\u304c\u5fc5\u8981\u3068\u306a\u308b\u307e\u3067\u4f4e\u4e0b\u3057\u307e\u3057\u305f\u3002Stabilwax\u30ab\u30e9\u30e0\u306f\u3001\u591a\u304f\u306e\u5de5\u696d\u7528\u5316\u5b66\u85ac\u54c1\u3084\u305d\u306e\u4ed6\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u5b9f\u8a3c\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u7528\u3067\u306fRtx-Wax\u30ab\u30e9\u30e0\u307b\u3069\u5805\u7262\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002Rtx-Wax\u30ab\u30e9\u30e0\u306f\u3001\u4e00\u8cab\u3057\u3066\u3001\u8907\u6570\u306e\u30ab\u30e9\u30e0\u30ed\u30c3\u30c8\u3068\u4eca\u56de\u306e\u691c\u8a3c\u306b\u304a\u3044\u3066\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\uff08<strong>Table I<\/strong>\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u3092\u5206\u6790\u3059\u308b\u30e9\u30dc\u3067\u306f\u3001Rtx-Wax\u30ab\u30e9\u30e0\u3067\u793a\u3057\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3092\u7528\u3044\u308b\u3053\u3068\u306b\u52a0\u3048\u3066\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u3092\u9632\u6b62\u3059\u308b\u3053\u3068\u3067\u3055\u3089\u306b\u7d50\u679c\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u304a\u3051\u308b\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u5185\u306e\u30b5\u30f3\u30d7\u30eb\u6b8b\u6e23\u304c\u6b21\u306e\u30b5\u30f3\u30d7\u30eb\u3078\u6301\u3061\u8d8a\u3055\u308c\u308b\u3053\u3068\u3067\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30b7\u30ea\u30f3\u30b8\u304c\u5206\u6790\u306e\u9593\u3067\u9069\u5207\u306b\u6d17\u6d44\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3084\u3001\u30ea\u30f3\u30b9\u6eb6\u5a92\u3068\u3057\u3066100\uff05\u306e\u6c34\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306b\u3088\u308b\u4e00\u8cab\u6027\u306e\u306a\u3044\u7d50\u679c\u3084\u3001\u30b7\u30ea\u30f3\u30b8\u30d7\u30e9\u30f3\u30b8\u30e3\u30fc\u306e\u7834\u640d\u306e\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5404\u6ce8\u5165\u306e\u9593\u306b\u30b7\u30ea\u30f3\u30b8\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\uff1a\u6c34\uff0850\uff1a50\uff09\u30673\uff5e6\u56de\u30ea\u30f3\u30b9\u3059\u308b\u3068\u3001\u307b\u3068\u3093\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u6b8b\u6e23\u306f\u306a\u304f\u306a\u308a\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u306e\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306e\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304a\u3088\u3073\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u306f\u3001600<br>\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u5909\u308f\u308a\u307e\u305b\u3093\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1454.png\" alt=\"Comparison of Glycols Before and After 600 Water Injections on Rtx-Wax\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1454<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30471<\/li><li>12455<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Rtx-Wax<\/li><li>glycols<\/li><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1454.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> Stabilwax\u30ab\u30e9\u30e0\u306f350\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3001\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c\u8457\u3057\u304f\u4f4e\u4e0b\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1470.png\" alt=\"Comparison of Glycols Before and After 350 Water Injections on Stabilwax\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1470<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30471<\/li><li>10655<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Rtx-Wax<\/li><li>glycols<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1470.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u30ab\u30e9\u30e0\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u305b\u305a\u306b\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th>&nbsp;<\/th><th colspan=\"3\"><strong>Average Peak Symmetry at 1 ng On-Column (Rtx-Wax, n = 3)<\/strong><\/th><\/tr><\/thead><tbody><tr><td><strong># of Water Injections<\/strong><\/td><td><strong>IS<\/strong><\/td><td><strong>Propylene Glycol<\/strong><\/td><td><strong>Ethylene Glycol<\/strong><\/td><\/tr><tr><td>100<\/td><td>0.97<\/td><td>0.96<\/td><td>0.99<\/td><\/tr><tr><td>200<\/td><td>0.98<\/td><td>0.95<\/td><td>0.98<\/td><\/tr><tr><td>300<\/td><td>0.98<\/td><td>0.95<\/td><td>0.99<\/td><\/tr><tr><td>400<\/td><td>0.96<\/td><td>0.95<\/td><td>0.99<\/td><\/tr><tr><td>500<\/td><td>0.97<\/td><td>0.94<\/td><td>1.00<\/td><\/tr><tr><td>600<\/td><td>0.97<\/td><td>0.92<\/td><td>0.99<\/td><\/tr><tr><td><strong>%RSD<\/strong><\/td><td>0.5%<\/td><td>1.2%<\/td><td>0.7%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u3088\u308b\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u3067\u306f\u3001\u5f93\u6765\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u6bd4\u3079\u3066\u3044\u304f\u3064\u304b\u306e\u5229\u70b9\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306e\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3068\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u306b\u3088\u308b\u554f\u984c\u3092\u9632\u6b62\u3067\u304d\u307e\u3059\u3002Rtx-Wax\u30ab\u30e9\u30e0\u3067\u793a\u3057\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3067\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u3001\u975e\u5e38\u306b\u5b89\u5b9a\u3057\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u30ab\u30e9\u30e0\u306b\u5165\u308b\u6c34\u304c\u5c11\u306a\u304f\u3001\u8fc5\u901f\u3067\u4e00\u8cab\u6027\u306e\u3042\u308b\u30b5\u30f3\u30d7\u30eb\u79fb\u52d5\u304c\u304a\u3053\u306a\u308f\u308c\u308b\u305f\u3081\u3001\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u306e\u5b89\u5b9a\u6027\u304c\u5b9f\u73fe\u3055\u308c\u3001\u6c34\u4e2d\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u4f4e\u6fc3\u5ea6\u5206\u6790\u306e\u518d\u73fe\u6027\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>J.D. Laukkonen, The history of antifreeze, Crankshift, March 1, 2017.\u00a0<a href=\"http:\/\/www.crankshift.com\/history-of-antifreeze\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/www.crankshift.com\/history-of-antifreeze\/<\/a><\/li>\n\n\n\n<li>S. Ritter, What\u2019s that stuff?, C&amp;EN, January 1st, 2001.\u00a0<a href=\"https:\/\/pubs.acs.org\/cen\/whatstuff\/stuff\/7901scit5.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/pubs.acs.org\/cen\/whatstuff\/stuff\/7901scit5.html<\/a><\/li>\n\n\n\n<li>FracFocus, Chemical disclosure registry, what chemicals are used.\u00a0<a href=\"https:\/\/fracfocus.org\/explore\/chemicals\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/fracfocus.org\/chemical-use\/what-chemicals-are-used<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/12455\">                                \u30ab\u30bf\u30ed\u30b0No. 12455                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-Wax GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.53 mm ID, 1.00 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/12455\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10655\">                                \u30ab\u30bf\u30ed\u30b0No. 10655                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Stabilwax GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.53 mm ID, 1.00 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10655\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30471\">                                \u30ab\u30bf\u30ed\u30b0No. 30471                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Glycols Standard, 50,000 \u00b5g\/mL, DI Water, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30471\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u7528\u3044\u305f\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u4f4e\u6fc3\u5ea6\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u3067\u306f\u3001\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u5f97\u308b\u306e\u304c\u56f0\u96e3\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u4e3b\u306b\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38\u3001\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u3068\u3044\u3063\u305f\u3053\u3068\u306b\u8d77\u56e0\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u793a\u3059\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u56de\u907f\u3057\u3001\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u7d50\u679c\u3092\u78ba\u5b9f\u306b\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u8010\u4e45\u6027\u8a66\u9a13\u3067\u306f\u3001Rtx-Wax\u30ab\u30e9\u30e0\u304c600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u751f\u6210\u3059\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":26,"featured_media":70285,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[2271,2287],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340,2342],"ppma_author":[446,441],"class_list":["post-43397","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-injection-techniques-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"industries-application":[{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2342,"label":"\u6ce8\u5165\u65b9\u6cd5"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN2873-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Corby Hilliard","author_link":"https:\/\/discover.restek.com\/ja\/author\/corby-hilliard\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":446,"user_id":26,"is_guest":0,"slug":"corby-hilliard","display_name":"Corby Hilliard","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg"},"author_category":"1","first_name":"Corby","last_name":"Hilliard","user_url":"https:\/\/www.linkedin.com\/in\/corby-hilliard-69b1ba275\/","job_title":"Advanced Scientist, GC Applied","description":"Corby Hilliard started his Restek career in the Quality Assurance department where he spent his first seven years as a QA analyst and worked his way up to a senior QA analyst. He then moved on to the Innovations department in 2009 as a GC Solutions Advanced Scientist. His experience is predominately in gas chromatography (GC) using various detectors and mass spectrometry as well as troubleshooting and method development. His primary work for Restek is generating product application data, using new and existing products in food safety, petrochemical, environmental, and the GC accessories line. He also is involved with quality and R&amp;D as well as new product development."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43397"}],"version-history":[{"count":13,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43397\/revisions"}],"predecessor-version":[{"id":81266,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43397\/revisions\/81266"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/70285"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43397"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43397"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43397"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43397"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43397"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43397"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43397"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43397"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}