{"id":43424,"date":"2020-10-15T14:30:00","date_gmt":"2020-10-15T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-rtx-wax-a-rugged-and-reliable-choice-for-the-analysis-of-glycols-in-water\/"},"modified":"2026-10-02T14:23:54","modified_gmt":"2026-10-02T14:23:54","slug":"japanese-rtx-wax-a-rugged-and-reliable-choice-for-the-analysis-of-glycols-in-water","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3086-ja\/japanese-rtx-wax-a-rugged-and-reliable-choice-for-the-analysis-of-glycols-in-water","title":{"rendered":"\u6c34\u6ce8\u5165\u306b\u5f37\u3044WAX\u30ab\u30e9\u30e0\u306f\uff1f\u30fcRtx-Wax\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u30fc"},"content":{"rendered":"\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u98db\u884c\u6a5f\u306a\u3069\u306e\u6ed1\u8d70\u8def\u306e\u9664\u6c37\u304b\u3089\u6cb9\u5727\u7834\u7815\u4f5c\u696d\u307e\u3067\u3001\u975e\u5e38\u306b\u5e45\u5e83\u3044\u7528\u9014\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30b0\u30ea\u30b3\u30fc\u30eb\u306f\u3055\u307e\u3056\u307e\u306a\u7523\u696d\u306b\u304a\u3044\u3066\u3001\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u7269\u8cea\u3067\u3042\u308a\u3001\u5316\u5b66\u7cfb\u30e9\u30dc\u304a\u3088\u3073\u74b0\u5883\u30e9\u30dc\u306a\u3069\u3067\u6b8b\u7559\u691c\u67fb\u304c\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u306e\u5206\u6790\u3067\u3082\u3063\u3068\u3082\u983b\u7e41\u306b\u7528\u3044\u3089\u308c\u308bGC\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u65b9\u6cd5\u306f\u3001\u6c34\u6eb6\u6db2\u306e\u76f4\u63a5\u6ce8\u5165\u3067\u3059\u304c\u3001\u3053\u306e\u5834\u5408\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3068\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u5927\u304d\u306a\u8ca0\u62c5\u304c\u304b\u304b\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u3053\u306e\u6c34\u6ce8\u5165\uff08\u6c34\u6eb6\u6db2\u6ce8\u5165\uff09\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u306f\u3001\u4e00\u822c\u7684\u306b\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PEG\uff09\u56fa\u5b9a\u76f8\u304c\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001PEG\u306f\u72ec\u81ea\u306e\u9078\u629e\u5236\u3092\u5099\u3048\u308b\u9ad8\u6975\u6027\u56fa\u5b9a\u76f8\u3067\u3042\u308a\u3001\u6c34\u6eb6\u5a92\u3068\u306e\u65b0\u4e16\u8a71\u6027\u304c\u9ad8\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u69d8\u3005\u306a\u30d9\u30f3\u30c0\u30fc\u306ePEG\u30ab\u30e9\u30e0\u3067\u3001\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08EG\uff09\u304a\u3088\u3073\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PG\uff09\u6c34\u6eb6\u6db2\u306e\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u3001\u6700\u9069\u5316\u3057\u305f\u6761\u4ef6\u3067\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u8a18\u4e8b\u3067\u306f\u3001Rtx-Wax\u306e\u7279\u5fb4\u3068\u5229\u70b9\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mokuji0\">\u3010\u76ee\u6b21\u3011<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rtx-Wax\u3092\u7528\u3044\u305f\u672c\u5206\u6790\u306e\u7279\u5fb4<\/li>\n\n\n\n<li>\u30d9\u30f3\u30c1\u30de\u30fc\u30ad\u30f3\u30b0<\/li>\n\n\n\n<li>\u5206\u6790\u7d50\u679c<\/li>\n\n\n\n<li>\u76f4\u7dda\u6027<\/li>\n\n\n\n<li>\u8010\u4e45\u6027<\/li>\n\n\n\n<li>\u30d6\u30ea\u30fc\u30c9<\/li>\n\n\n\n<li>Rtx-Wax\u3092\u7528\u3044\u305f\u672c\u5206\u6790\u306e\u7d50\u8ad6<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji1\">Rtx-Wax\u3092\u7528\u3044\u305f\u672c\u5206\u6790\u306e\u7279\u5fb4<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u3044\u8010\u4e45\u6027\u304c\u3042\u308a\u3001\u7e70\u308a\u8fd4\u3057\u306e\u6c34\u6ce8\u5165\u306b\u8010\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3082\u5bfe\u79f0\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u7dad\u6301\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u4f4e\u30d6\u30ea\u30fc\u30c9\u3067\u3001\u6700\u5c0f0.5 ng\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u3092\u6b63\u78ba\u306a\u691c\u51fa\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji2\">\u30d9\u30f3\u30c1\u30de\u30fc\u30ad\u30f3\u30b0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306e\u5206\u6790\u30fb\u7814\u7a76\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u4f7f\u7528\u3057\u30013\u3064\u306e\u7570\u306a\u308b\u30ab\u30e9\u30e0\u3067\u76f4\u7dda\u6027\u3001\u8010\u4e45\u6027\u3001\u304a\u3088\u3073\u30d6\u30ea\u30fc\u30c9\u306b\u3064\u3044\u3066\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u6700\u9069\u5316\u3057\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u306e\u8a73\u7d30\u306f\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8<a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan2873-ja\/reliable-low-level-analysis-of-glycols-in-water-using-split-injection-japan\">EVAN2873<\/a>\u3067\u8a73\u3057\u304f\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Restek\u30ab\u30e9\u30e0\n<ul class=\"wp-block-list\">\n<li>Rtx-Wax\uff08cat.# 12455\uff09<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Restek\u4ee5\u5916\u306e\u30ab\u30e9\u30e0\n<ul class=\"wp-block-list\">\n<li>\u30ab\u30e9\u30e0A<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0B<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7814\u7a76\u3067\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u3092\u5206\u6790\u306b\u4f7f\u7528\u3057\u305f\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u306f\u65b0\u54c1\u3067\u300130 m\u30010.53 mm\u30011.0 \u00b5m\u3067\u3059\u3002\u305d\u308c\u3089\u306f\u3059\u3079\u3066\u3001\u30e9\u30d9\u30eb\u306b\u8a18\u8f09\u3055\u308c\u305f\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u30671\u6642\u9593\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u304a\u3053\u306a\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji3\">\u5206\u6790\u7d50\u679c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u95a2\u3059\u308b\u30d9\u30f3\u30c1\u30de\u30fc\u30ad\u30f3\u30b0\u7814\u7a76\u306e\u7d50\u679c\u306f\u3001<strong>Table I<\/strong>\u306b\u307e\u3068\u3081\u3089\u308c\u3001\u4ee5\u4e0b\u3067\u8a73\u7d30\u306b\u8ad6\u3058\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u30ab\u30e9\u30e0\u306e\u30d9\u30f3\u30c1\u30de\u30fc\u30ad\u30f3\u30b0\u7d50\u679c<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td rowspan=\"3\"><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td colspan=\"3\"><strong>\u5bff\u547d<\/strong><\/td><td colspan=\"2\"><strong>\u76f4\u7dda\u6027<\/strong><\/td><td><strong>\u30d6\u30ea\u30fc\u30c9<\/strong><\/td><\/tr><tr><td rowspan=\"2\"><strong>\u901a\u904e\u3057\u305f\u6ce8\u5165 *<\/strong><\/td><td colspan=\"2\"><strong>\u30d4\u30fc\u30af\u306e\u5bfe\u79f0\u6027 (\u6700\u7d42\u6ce8\u5165)<\/strong><\/td><td colspan=\"2\"><strong>\u6700\u7d42 r<sup>2<\/sup><\/strong><\/td><td rowspan=\"2\"><strong>240\u2103\u3067\u306eFID\u53cd\u5fdc (pA)<\/strong><\/td><\/tr><tr><td><strong>EG<\/strong><\/td><td><strong>PG<\/strong><\/td><td><strong>EG<\/strong><\/td><td><strong>PG<\/strong><\/td><\/tr><tr><td>&nbsp;<\/td><td>600<\/td><td>0.99<\/td><td>0.92<\/td><td>0.9999<\/td><td>0.9999<\/td><td>29<\/td><\/tr><tr><td>\u30ab\u30e9\u30e0A<\/td><td colspan=\"5\"><em>\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u4e0b\u9650\u304c\u6e80\u305f\u3055\u308c\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u8010\u4e45\u6027\u8a66\u9a13\u306f\u5b9f\u65bd\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f<\/em><\/td><td>53<\/td><\/tr><tr><td>\u30ab\u30e9\u30e0B<\/td><td colspan=\"5\"><em>\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u4e0b\u9650\u304c\u6e80\u305f\u3055\u308c\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u8010\u4e45\u6027\u8a66\u9a13\u306f\u5b9f\u65bd\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f<\/em><\/td><td>60<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u5b9f\u9a13\u306f\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027 (ChemStation \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3066\u6c7a\u5b9a\u3055\u308c\u305f\u5024) \u304c 0.5 \u672a\u6e80\u306b\u4f4e\u4e0b\u3059\u308b\u304b\u3001\u307e\u305f\u306f\u6ce8\u5165\u56de\u6570\u304c 600 \u56de\u306b\u9054\u3059\u308b\u307e\u3067\u3001\u3069\u3061\u3089\u304b\u65e9\u3044\u65b9\u307e\u3067\u7e70\u308a\u8fd4\u3059\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u307e\u3057\u305f\u3002\u3059\u3079\u3066\u306e\u6ce8\u5165\u306f\u30aa\u30f3\u30ab\u30e9\u30e0\u30671 ng\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mokuji4\">\u76f4\u7dda\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5404\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u3001\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u9069\u3057\u305f\u76f4\u7dda\u6027\u3092\u78ba\u7acb\u3057\u3001\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u30670.5 ng\u304b\u3089100 ng\u306e\u306e\u521d\u671f\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002 \u691c\u91cf\u7dda\u306e\u6700\u3082\u4f4e\u30442\u3064\u306e\u30ec\u30d9\u30eb\u30010.5\u304a\u3088\u30731.0 ng\u306e\u30aa\u30f3\u30ab\u30e9\u30e0\u3067\u306f\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u304c\u9ad8\u304fEG\u3068PG\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u7af6\u5408\u4ed6\u793e\u306e\u30ab\u30e9\u30e0A\u304a\u3088\u3073B\u306f\u76f4\u7dda\u6027\u3068\u8010\u4e45\u6027\u306e\u5b9f\u9a13\u304b\u3089\u9664\u5916\u3057\u307e\u3057\u305f\u3002<br>&nbsp;<br>\u305d\u308c\u306b\u5bfe\u3057\u3001Rtx-Wax\u30ab\u30e9\u30e0\u3067\u306fEG\u3068PG\u306e\u4e21\u65b9\u3067\u512a\u308c\u305f\u76f4\u7dda\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\uff08<strong>Figure 1<\/strong>\u304a\u3088\u3073<strong>Figure 2<\/strong>\uff09\u3002 \u6c34\u304c\u30ab\u30e9\u30e0\u3078\u6f5c\u5728\u7684\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067600\u56de\u3082\u306e\u6c34\u6ce8\u5165\u3068\u3044\u3046\u53b3\u3057\u3044\u6761\u4ef6\u4e0b\u306b\u304a\u3044\u3066\u3082\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306f\u5bb9\u6613\u304f\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u30c1\u30a7\u30c3\u30af\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002 \u306a\u304a\u3001\u4f4e\u30d6\u30ea\u30fc\u30c9\u7279\u6027\u306e\u30ab\u30e9\u30e0\u306e\u7d50\u679c\u3068\u3057\u3066\u3001EG\u3068PG\u306e\u4f4e\u6fc3\u5ea6\u3067\u306e\u9ad8\u3044\u30ec\u30b9\u30dd\u30f3\u30b9\u306f\u3001\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u7bc4\u56f2\u5168\u4f53\u3067\u512a\u308c\u305f\u76f4\u7dda\u6027\u3092\u5f97\u308b\u4e00\u56e0\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u3001\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff080.5\u2013100 ng\u30aa\u30f3\u30ab\u30e9\u30e0\uff09\u5206\u6790\u306b\u304a\u3044\u3066\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAR3086-01.jpg\" alt=\"figure-article-EVAR3086-01.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3067\u3082\u3001\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff080.5\u2013100 ng\u30aa\u30f3\u30ab\u30e9\u30e0\uff09\u5206\u6790\u306b\u304a\u3044\u3066\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVAR3086-02.jpg\" alt=\"figure-article-EVAR3086-02.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mokuji5\">\u8010\u4e45\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Rtx-Wax\u30ab\u30e9\u30e0\u306e\u8010\u4e45\u6027\u8a66\u9a13\u306f\u3001\u6c34\u309210\u56de( 1 \u00b5L \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9)\u6ce8\u5165\u3057\u305f\u5f8c\u306b\u300150\u00b5g\/mL\u30b0\u30ea\u30b3\u30fc\u30eb\u6a19\u6e96\u6db2( 50:1 \u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf 1 ng)\u3092\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002 \u5b9f\u9a13\u306f\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027 (ChemStation \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3066\u6c7a\u5b9a\u3055\u308c\u305f\u5024) \u304c 0.5 \u672a\u6e80\u306b\u4f4e\u4e0b\u3059\u308b\u304b\u3001\u307e\u305f\u306f\u6ce8\u5165\u56de\u6570\u304c 600 \u56de\u306b\u9054\u3059\u308b\u307e\u3067\u3001\u3069\u3061\u3089\u304b\u65e9\u3044\u65b9\u307e\u3067\u7e70\u308a\u8fd4\u3059\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u307e\u3057\u305f\u3002 <strong>Figure 3<\/strong>\u306b\u793a\u3057\u305f\u3088\u3046\u306b\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306f600\u56de\u306e\u6ce8\u5165\u5f8c\u3067\u3082\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u7dad\u6301\u3057\u307e\u3057\u305f\u3002 \u5b9f\u969b\u306e\u3068\u3053\u308d\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306f\u62e1\u5f35\u8010\u4e45\u6027\u5b9f\u9a13\u30671600\u56de\u4ee5\u4e0a\u306e\u6c34\u6ce8\u5165\u306b\u8010\u3048\u3001\u6700\u5f8c\u306e\u5b9f\u9a13\u3067\u3082\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c0.9\u3092\u4e0a\u56de\u3063\u3066\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306e\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3068\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304a\u3088\u3073\u4fdd\u6301\u6642\u9593\u306f\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u5f8c\u3082\u5909\u308f\u308a\u307e\u305b\u3093\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1454.png\" alt=\"Comparison of Glycols Before and After 600 Water Injections on Rtx-Wax\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1454<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30471<\/li><li>12455<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Rtx-Wax<\/li><li>glycols<\/li><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1454.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mokuji6\">\u30d6\u30ea\u30fc\u30c9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u5206\u6790\u306b\u304a\u3051\u308bPEG\u30ab\u30e9\u30e0\u8a55\u4fa1\u306e\u6700\u7d42\u30c6\u30b9\u30c8\u306f\u3001\u30d6\u30ea\u30fc\u30c9\u5b9f\u9a13\u3067\u3059\u3002 3\u3064\u306e\u30ab\u30e9\u30e0\u3059\u3079\u3066\u3092\u4e00\u822c\u7684\u306a\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u3067\u3042\u308b240\u00b0C\u307e\u3067\u6607\u6e29\u3057\u307e\u3057\u305f\u3002 \u6700\u7d42\u306e\u30d6\u30ea\u30fc\u30c9\u6e2c\u5b9a\u3067\u306f\u3001Rtx-Wax\u304c\u6700\u3082\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u793a\u3059\u7d50\u679c\u3068\u306a\u308a\u307e\u3057\u305f\uff08<strong>Table I<\/strong>\u3001<strong>Figure 4<\/strong>\uff09\u3002 \u305f\u3060\u3057\u3001Rtx-Wax\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f\u3001\u3053\u308c\u3088\u308a\u3082\u9ad8\u3044\uff08250\u00b0C\uff09\u305f\u3081\u3001\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u304c\u5fc5\u8981\u306a\u5834\u5408\u3067\u3082\u5b89\u5fc3\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u306a\u304a\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u304c\u4f4e\u3044\u305f\u3081\u3001\u5206\u6790\u5bfe\u8c61\u7269\u306e\u6fc3\u5ea6\u304c\u4f4e\u3044\u5834\u5408\u3067\u3082\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> Rtx-Wax\u30ab\u30e9\u30e0\u306f\u3001\u691c\u8a3c\u3055\u308c\u305f\u30ab\u30e9\u30e0\u306e\u4e2d\u3067\u6700\u3082\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u793a\u3057\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\uff08\u7af6\u5408\u4ed6\u793e\u30ab\u30e9\u30e0\u306f240\u00b0C\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306f250\u00b0C\uff09\u3067\u3082\u4f4e\u3044\u307e\u307e\u3067\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1456.png\" alt=\"Rtx-Wax Bleed Profile Comparison\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1456<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>12455<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1456.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji7\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7814\u7a76\u3067\u8a55\u4fa1\u3057\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u30d9\u30fc\u30b9\u306e\u30ab\u30e9\u30e0\u306e\u4e2d\u3067\u3001Rtx-Wax\u306f\u76f4\u7dda\u6027\u3001\u8010\u4e45\u6027\u3001\u304a\u3088\u3073\u30d6\u30ea\u30fc\u30c9\u306e\u9762\u3067\u6700\u3082\u512a\u308c\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001600\u56de\u306e\u6c34\u6ce8\u5165\u3068\u3044\u3046\u904e\u9177\u306a\u6761\u4ef6\u5f8c\u3067\u3082\u3001\u521d\u3081\u306e\u6ce8\u5165\u3068\u540c\u69d8\u306b\u512a\u308c\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u70b9\u306b\u304a\u3044\u3066\u3001Rtx-Wax\u306f\u3001\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u304a\u3044\u3066\u9811\u4e08\u3067\u4fe1\u983c\u6027\u306e\u3042\u308b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/12455\">                                \u30ab\u30bf\u30ed\u30b0No. 12455                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-Wax GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.53 mm ID, 1.00 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/12455\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6c34\u4e2d\u306e\u30b0\u30ea\u30b3\u30fc\u30eb\u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001\u7570\u306a\u308b\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u767a\u58f2\u3055\u308c\u3066\u3044\u308b\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PEG\uff09\u30ab\u30e9\u30e03\u7a2e\u985e\u306b\u3064\u3044\u3066\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u4eca\u56de\u306e\u8a55\u4fa1\u8a66\u9a13\u3067\u306f600\u56de\u306e\u6c34\u6ce8\u5165\uff08\u6c34\u6eb6\u6db2\u6ce8\u5165\uff09\u5b9f\u65bd\u5f8c\u3001\u76f4\u7dda\u6027\u3001\u8010\u4e45\u6027\u3001\u304a\u3088\u3073\u30d6\u30ea\u30fc\u30c9\u306b\u95a2\u3059\u308b\u30c7\u30fc\u30bf\u6bd4\u8f03\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001Rtx-Wax\u30ab\u30e9\u30e0\u306f\u8a55\u4fa1\u8a66\u9a13\u3092\u901a\u3058\u3066\u826f\u597d\u306a\u6027\u80fd\u3092\u793a\u3059\u552f\u4e00\u306e\u30ab\u30e9\u30e0\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u3068\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":26,"featured_media":70524,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789,7],"tags":[],"industries-application":[2270,2265,2271],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[446,441],"class_list":["post-43424","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","category-articles","industries-application-energy-ja","industries-application-chemical-production-ja","industries-application-environmental-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"},{"value":7,"label":"Articles"}],"industries-application":[{"value":2270,"label":"\u30a8\u30cd\u30eb\u30ae\u30fc"},{"value":2265,"label":"\u5316\u5b66\u88fd\u54c1\u88fd\u9020"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAR3086-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Corby Hilliard","author_link":"https:\/\/discover.restek.com\/ja\/author\/corby-hilliard\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0},{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":446,"user_id":26,"is_guest":0,"slug":"corby-hilliard","display_name":"Corby Hilliard","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg"},"author_category":"1","first_name":"Corby","last_name":"Hilliard","user_url":"https:\/\/www.linkedin.com\/in\/corby-hilliard-69b1ba275\/","job_title":"Advanced Scientist, GC Applied","description":"Corby Hilliard started his Restek career in the Quality Assurance department where he spent his first seven years as a QA analyst and worked his way up to a senior QA analyst. He then moved on to the Innovations department in 2009 as a GC Solutions Advanced Scientist. His experience is predominately in gas chromatography (GC) using various detectors and mass spectrometry as well as troubleshooting and method development. His primary work for Restek is generating product application data, using new and existing products in food safety, petrochemical, environmental, and the GC accessories line. He also is involved with quality and R&amp;D as well as new product development."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43424","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43424"}],"version-history":[{"count":11,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43424\/revisions"}],"predecessor-version":[{"id":89610,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43424\/revisions\/89610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/70524"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43424"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43424"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43424"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43424"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43424"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43424"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43424"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43424"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43424"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}