{"id":43494,"date":"2022-05-11T00:00:00","date_gmt":"2022-05-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-improve-semivolatiles-method-performance-with-rxi-svocms-columns\/"},"modified":"2026-01-14T18:56:17","modified_gmt":"2026-01-14T18:56:17","slug":"japanese-improve-semivolatiles-method-performance-with-rxi-svocms-columns","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evfa3821-ja\/japanese-improve-semivolatiles-method-performance-with-rxi-svocms-columns","title":{"rendered":"Rxi\u2010SVOCms\u30ab\u30e9\u30e0\u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u7269\u8cea\u306e\u5206\u6790\u6cd5\u6027\u80fd\u306e\u5411\u4e0a"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-1 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-width:1px;border-radius:0px;padding-top:0;padding-bottom:0\">\n<p class=\"has-text-align-center has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-2 wp-block-paragraph\"><strong><em>SelectScience Scientists&#8217; Choice\u8cde\u306e\u300c\u5e74\u9593\u6700\u512a\u79c0\u65b0\u898f\u5206\u96e2\u88fd\u54c1\u300d\u3092\u53d7\u8cde\uff01<\/em><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u30ec\u30b9\u30dd\u30f3\u30b9\u3001\u5206\u96e2\u304c\u826f\u304f\u3001\u7cbe\u78ba\u3055\u3068\u611f\u5ea6\u3092\u78ba\u5b9f\u306a\u3082\u306e\u306b\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3001\u8d85\u4f4e\u30d6\u30ea\u30fc\u30c9\u30ab\u30e9\u30e0\u306b\u3088\u308a\u3001\u5fae\u91cf\u6fc3\u5ea6\u306e\u6d3b\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u512a\u308c\u305f\u7d50\u679c\u304c\u3082\u305f\u3089\u3055\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5b89\u5b9a\u3057\u305f\u691c\u91cf\u7dda\u3068\u30ab\u30e9\u30e0\u9593\u306e\u4e00\u8cab\u3057\u305f\u6027\u80fd\u306b\u3088\u308a\u3001\u751f\u7523\u6027\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u6cd5\u306f\u74b0\u5883\u5206\u6790\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u304a\u3044\u3066\u4e0d\u53ef\u6b20\u306a\u3082\u306e\u3067\u3059\u304c\u3001\u5bfe\u8c61\u5206\u6790\u7269\u306e\u30ea\u30b9\u30c8\u304c\u5e83\u7bc4\u56f2\u306b\u53ca\u3073\u3001\u3055\u307e\u3056\u307e\u306a\u7a2e\u985e\u306e\u53cd\u5fdc\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u3092\u542b\u3080\u305f\u3081\u3001\u30e9\u30dc\u304c\u52b9\u7387\u7684\u306b\u5b9f\u65bd\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306a\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u3001\u7279\u306b\u53cd\u5fdc\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u3092\u6b63\u78ba\u306b\u5831\u544a\u3059\u308b\u5834\u5408\u3001\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u5b89\u5b9a\u3057\u305f\u691c\u91cf\u7dda\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u3001\u9ad8\u5ea6\u306b\u4e0d\u6d3b\u6027\u306a\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1680\" target=\"_blank\" rel=\"noopener\">Rxi-SVOCms<\/a>\u306f\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u7279\u5316\u3057\u305f\u30ab\u30e9\u30e0\u3067\u3001\u6700\u9069\u306a\u9078\u629e\u6027\u3001\u512a\u308c\u305f\u4e0d\u6d3b\u6027\u5ea6\u3001\u6975\u3081\u3066\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u7279\u5fb4\u3068\u3057\u3001\u5206\u6790\u6027\u80fd\u306e\u5411\u4e0a\u3068\u30e9\u30dc\u306e\u751f\u7523\u6027\u5411\u4e0a\u306b\u8ca2\u732e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u6cd5\u3067\u554f\u984c\u3068\u306a\u308b\u9178\u6027\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\uff08\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u3001\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\uff09\u3084\u30a2\u30df\u30f3\u985e\uff08\u30d9\u30f3\u30b8\u30b8\u30f3\u3001\u30d4\u30ea\u30b8\u30f3\uff09\u306a\u3069\u591a\u69d8\u306a\u53cd\u5fdc\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5f97\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u5b9f\u969b\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u306b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u306b\u3088\u3063\u3066\u4f5c\u3089\u308c\u308b\u6d3b\u6027\u30b5\u30a4\u30c8\u306e\u84c4\u7a4d\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u3053\u306e\u6ce8\u5165\u6cd5\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002 Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u6975\u3081\u3066\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u305f\u3081\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3084\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u6539\u5584\u3055\u308c\u3001\u6b63\u78ba\u306a\u7a4d\u5206\u304c\u5bb9\u6613\u304b\u3064\u78ba\u5b9f\u306b\u304a\u3053\u306a\u3048\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6027\u80fd\u304c\u5411\u4e0a\u3059\u308b\u3068\u3001\u611f\u5ea6\u3068\u518d\u73fe\u6027\u304c\u6539\u5584\u3055\u308c\u308b\u305f\u3081\u3001\u691c\u91cf\u7dda\u306f\u3088\u308a\u9577\u3044\u671f\u9593\u30d1\u30b9\u3057\u3001\u518d\u6821\u6b63\u304c\u5fc5\u8981\u306b\u306a\u308b\u524d\u306b\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5869\u57fa\u6027\u3001\u9178\u6027\u306e\u53cd\u5fdc\u6027\u5316\u5408\u7269\u306b\u5bfe\u3059\u308b\u6027\u80fd\u5411\u4e0a\u306b\u52a0\u3048\u3001\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u6cd5\u3067\u6700\u3082\u554f\u984c\u3068\u306a\u308b\u4e2d\u6027\u306e\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAH\uff09\u306b\u5bfe\u3057\u3066\u3082\u512a\u308c\u305f\u5206\u96e2\u80fd\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30a4\u30f3\u30c7\u30ce[1,2,3-cd]\u30d4\u30ec\u30f3\u3068\u30b8\u30d9\u30f3\u30be[a,h]\u30a2\u30f3\u30c8\u30e9\u30bb\u30f3\u3001\u30d9\u30f3\u30be[b]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3068\u30d9\u30f3\u30be[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u306a\u3069\u306e\u91cd\u8981\u306a\u30da\u30a2\u306fRxi-SVOCms\u30ab\u30e9\u30e0\u3067\u3088\u304f\u5206\u96e2\u3067\u304d\u3001\u6b63\u78ba\u306a\u540c\u5b9a\u3068\u5831\u544a\u304c\u53ef\u80fd\u3067\u3059\u3002 Rxi-SVOCms \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5b89\u5b9a\u3057\u305f\u9ad8\u54c1\u8cea\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5b9f\u73fe\u3057\u3001\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u6cd5\u306e\u6027\u80fd\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 1:<\/strong>\u00a0Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u6709\u3057\u3001\u56f0\u96e3\u306a\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304a\u3088\u3073\u5206\u96e2\u80fd\u3092\u3082\u305f\u3089\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1607.png\" alt=\"Semivolatiles Analysis on Rxi-SVOCms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1607<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31886<\/li><li>31888<\/li><li>31063<\/li><li>31850<\/li><li>31852<\/li><li>31879<\/li><li>32459<\/li><li>31806<\/li><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1607.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u7528\u306b\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u305f\u4e0d\u6d3b\u6027\u306aRxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u56f0\u96e3\u306a\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u5e38\u306b\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304a\u3088\u3073\u5fdc\u7b54\u3092\u793a\u3057\u307e\u3059\u3002\u6539\u5584\u3055\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3088\u308a\u3001\u691c\u91cf\u7dda\u304c\u9577\u6301\u3061\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306f\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":6721,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2289,2272,2271,2287],"post-badge":[],"resource-type":[],"product-library":[2551,2564,2566,2552,2560,2555,2585,2551,2554],"resource-technique":[2365,2340,2345],"ppma_author":[2814],"class_list":["post-43494","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-soil-sediment-biota-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","product-library-air-gas-sampling-products-ja","product-library-gc-columns-ja","product-library-inlet-supplies-ja","product-library-gas-chromatography-products-ja","product-library-gas-standards-accessories-ja","product-library-sample-preparation-products-ja","product-library-vials-accessories-ja","product-library-reference-standard-products-ja","resource-technique-ms-ms-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"product-library":[{"value":2551,"label":"\u5927\u6c17\uff5c\u30ac\u30b9 \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2560,"label":"\u30ac\u30b9\u6821\u6b63\u7528\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"},{"value":2585,"label":"\u30d0\u30eb\u30d6 \uff5c \u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2551,"label":"\u5927\u6c17\uff5c\u30ac\u30b9 \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3821-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43494"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43494\/revisions"}],"predecessor-version":[{"id":81354,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43494\/revisions\/81354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6721"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43494"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43494"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43494"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43494"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43494"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43494"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43494"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43494"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}