{"id":43530,"date":"2022-05-30T14:30:00","date_gmt":"2022-05-30T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/see-semivolatiles-clearly-with-rugged-reliable-rxi-svocms-columns-japan\/"},"modified":"2026-01-02T14:02:54","modified_gmt":"2026-01-02T14:02:54","slug":"see-semivolatiles-clearly-with-rugged-reliable-rxi-svocms-columns-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evss3820-ja\/see-semivolatiles-clearly-with-rugged-reliable-rxi-svocms-columns-japan","title":{"rendered":"SVOC\u5206\u6790\u5c02\u7528\u30ab\u30e9\u30e0 Rxi-SVOCms\u30ab\u30e9\u30e0\u3067\u9ad8\u7cbe\u5ea6\u306aSVOC\u5206\u6790\u3068PAH\u5206\u96e2"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3067\u6b63\u78ba\u306a\u6821\u6b63\u3068\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u3092\u5b9f\u73fe<\/li>\n\n\n\n<li>\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u306e\u512a\u308c\u305f\u5206\u96e2\u3067\u5206\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u9593\u3067\u4e00\u8cab\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee<\/li>\n\n\n\n<li>\u9577\u5bff\u547d\u30ab\u30e9\u30e0\u3067\u4f5c\u696d\u52b9\u7387\u30a2\u30c3\u30d7<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-bd33745f939459039df7416ef688bd69 is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"border-width:1px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center wp-block-paragraph\"><strong><em>\u00a0SelectScience Scientists&#8217; Choice\u8cde\u306e\u300c\u5e74\u9593\u6700\u512a\u79c0\u65b0\u898f\u5206\u96e2\u88fd\u54c1\u300d\u3092\u53d7\u8cde\uff01<\/em><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u5206\u6790\u306b\u304a\u3051\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u5206\u6790\u306f\u3001\u7cbe\u5ea6\u3068\u4fe1\u983c\u6027\u304c\u6c42\u3081\u3089\u308c\u3001\u975e\u5e38\u306b\u96e3\u6613\u5ea6\u304c\u9ad8\u3044\u8ab2\u984c\u3068\u3057\u3066\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306b\u3001\u5206\u6790\u5bfe\u8c61\u3068\u306a\u308b\u5316\u5408\u7269\u304c\u9178\u6027\u3001\u5869\u57fa\u6027\u3001\u4e2d\u6027\u306a\u3069\u3055\u307e\u3056\u307e\u306a\u7279\u6027\u3092\u6301\u3064\u5834\u5408\u3001\u518d\u73fe\u6027\u306e\u3042\u308b\u5b89\u5b9a\u3057\u305f\u5206\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u3055\u3089\u306b\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u3053\u3067Restek\u306f\u3001\u9577\u671f\u9593\u5b89\u5b9a\u3057\u305f\u5206\u6790\u3092\u53ef\u80fd\u3068\u3059\u308b\u3001SVOC\u5206\u6790\u306e\u305f\u3081\u306e\u5c02\u7528\u30ab\u30e9\u30e0Rxi-SVOCms\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u306eSVOC\u5206\u6790\u5c02\u7528\u30ab\u30e9\u30e0\u306f\u9577\u671f\u9593\u306b\u308f\u305f\u3063\u3066\u6b63\u78ba\u306a\u6821\u6b63\u3092\u7dad\u6301\u3067\u304d\u308b\u305f\u3081\u3001\u88c5\u7f6e\u306e\u518d\u6821\u6b63\u3084\u30ab\u30e9\u30e0\u4ea4\u63db\u306e\u983b\u5ea6\u3092\u6291\u3048\u3064\u3064\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u65b0\u898f\u30dd\u30ea\u30de\u30fc\u3068\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3092\u63a1\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u975e\u5e38\u306b\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u8a87\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u52a0\u3048\u3001SVOC\u5206\u6790\u30ab\u30e9\u30e0\u3068\u3057\u3066\u6700\u9069\u306a\u5206\u96e2\u3092\u63d0\u4f9b\u3059\u308b\u305f\u3081\u306b\u3001\u53b3\u5bc6\u306b\u305d\u306e\u9078\u629e\u6027\u3092\u5236\u5fa1\u3057\u3066\u3044\u307e\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u7279\u6027\u3092\u6301\u3064\u5e45\u5e83\u3044\u6210\u5206\u3092\u9ad8\u3044\u7cbe\u5ea6\u3067\u5206\u96e2\u3059\u308b\u3053\u3068\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u512a\u308c\u305f\u6027\u80fd\u306b\u3088\u3063\u3066SVOC\u306e\u5206\u6790\u3092\u5927\u5e45\u306b\u6539\u5584\u3057\u307e\u3059\u3002\u7279\u306b\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u3084\u30d4\u30ea\u30b8\u30f3\u3001\u30d9\u30f3\u30b8\u30b8\u30f3\u306a\u3069\u3001\u901a\u5e38\u3067\u306f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u4e0d\u5b89\u5b9a\u306b\u306a\u308a\u3084\u3059\u3044\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u3001\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u3092\u5f62\u6210\u3057\u3001\u9ad8\u3044\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u5b9f\u73fe\u3057\u307e\u3059\uff08<strong>Figure 1<\/strong>\u53c2\u7167\uff09\u3002\u3055\u3089\u306b\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAH\uff09\u306e\u5206\u96e2\u3082\u6700\u9069\u5316\u3057\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308b\u5206\u96e2\u304c\u5fc5\u9808\u3068\u306a\u308b\u540c\u91cd\u4f53PAH\u3067\u3042\u308b\u30d9\u30f3\u30be[b]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3068\u30d9\u30f3\u30be[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u306b\u3064\u3044\u3066\u306f\u3001\u512a\u308c\u305f\u5206\u96e2\u5ea6\uff08\u30d0\u30ec\u30fc\u6bd485%\u4ee5\u4e0a\uff09\u304c\u5f97\u3089\u308c\u3066\u304a\u308a\u3001\u30a4\u30f3\u30c7\u30ce[1,2,3-cd]\u30d4\u30ec\u30f3\u3068\u30b8\u30d9\u30f3\u30be[a,h]\u30a2\u30f3\u30c8\u30e9\u30bb\u30f3\u306b\u3064\u3044\u3066\u3082\u540c\u69d8\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u7523\u696d\u3067\u5206\u6790\u3092\u62c5\u5f53\u3059\u308b\u5316\u5b66\u8005\u306b\u3068\u3063\u3066\u3001\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u304c\u5b89\u5b9a\u3057\u306a\u3044\u3053\u3068\u3084\u983b\u7e41\u306a\u6821\u6b63\u5931\u6557\u3001\u30ab\u30e9\u30e0\u5bff\u547d\u306e\u77ed\u3055\u306f\u5927\u304d\u306a\u60a9\u307f\u306e\u7a2e\u3067\u3059\u3002\u3057\u304b\u3057\u3001Rxi-SVOCms\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u3067\u3001\u3053\u308c\u3089\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3067\u304d\u307e\u3059\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306f\u5805\u7262\u3067\u3001\u9577\u671f\u9593\u306b\u308f\u305f\u3063\u3066\u5b89\u5b9a\u3057\u305f\u30c7\u30fc\u30bf\u54c1\u8cea\u3092\u7dad\u6301\u3057\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Rxi-SVOCms \u30ab\u30e9\u30e0\u306f\u512a\u308c\u305f\u5206\u6790\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001\u554f\u984c\u306e\u3042\u308b\u5316\u5408\u7269\u3067\u3042\u3063\u3066\u3082\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5206\u96e2\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u30ab\u30e9\u30e0\u306b\u79fb\u9001\u3059\u308b\u969b\u306e\u3001\u6ce8\u5165\u53e3\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u53ef\u80fd\u306a\u9650\u308a\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u63a8\u5968\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.png\" alt=\"Semivolatiles Analysis on Rxi-SVOCms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1604<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31850<\/li><li>31852<\/li><li>31879<\/li><li>31886<\/li><li>31888<\/li><li>31063<\/li><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b89\u5b9a\u3057\u305f\u6821\u6b63\u304c\u5b9f\u73fe\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5411\u4e0a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u5206\u6790\u3092\u9032\u3081\u308b\u4e0a\u3067\u3001\u5b89\u5b9a\u3057\u305f\u6821\u6b63\u3068\u30c7\u30fc\u30bf\u54c1\u8cea\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u304c\u3001\u7279\u306b\u30ec\u30b9\u30dd\u30f3\u30b9\u30d5\u30a1\u30af\u30bf\u30fc\u306e\u3070\u3089\u3064\u304d\u3084\u4e0d\u5b89\u5b9a\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u3001\u751f\u7523\u6027\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u5927\u304d\u306a\u8981\u56e0\u3068\u306a\u308a\u307e\u3059\u3002\u518d\u6821\u6b63\u3084\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u304b\u304b\u308b\u6642\u9593\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306e\u505c\u6b62\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u4f5c\u696d\u52b9\u7387\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3089\u3067\u3059\u3002Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3068\u512a\u308c\u305f\u6027\u80fd\u306b\u3088\u308a\u3001\u6821\u6b63\u306e\u7cbe\u5ea6\u3092\u5927\u5e45\u306b\u6539\u5584\u3057\u307e\u3059\u30026\u672c\u306e\u30ab\u30e9\u30e0\u3067\u884c\u3063\u305f\u521d\u671f\u6821\u6b63\u306b\u304a\u3044\u3066\u3001\u5f97\u3089\u308c\u305f\u30ec\u30b9\u30dd\u30f3\u30b9\u30d5\u30a1\u30af\u30bf\u30fc\u306e\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u306e\u5e73\u5747\u306f\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306a\u3089\u3073\u306b6\u672c\u306e\u30ab\u30e9\u30e0\u5168\u4f53\u3067\u308f\u305a\u304b6%\u3068\u3044\u3046\u7d50\u679c\u3068\u306a\u308a\u307e\u3057\u305f\uff08<strong>Table I<\/strong>\uff09\u3002\u3053\u306e\u4f4e\u3044%RSD\u306f\u30ab\u30e9\u30e0\u9593\u3067\u306e\u4e00\u8cab\u6027\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306b\u3088\u308a\u6821\u6b63\u306e\u6301\u7d9a\u6027\u304c\u5411\u4e0a\u3057\u3001\u518d\u6821\u6b63\u306e\u983b\u5ea6\u3092\u6291\u3048\u306a\u304c\u3089\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30d4\u30ea\u30b8\u30f3\u3084\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u306f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u30c6\u30fc\u30ea\u30f3\u30b0\u3057\u3084\u3059\u304f\u3001\u7279\u306b\u3001\u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5ea6\u304c\u9ad8\u304f\u306a\u3044\u5834\u5408\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u306f\u4e0d\u5b89\u5b9a\u3067\u518d\u73fe\u6027\u306b\u6b20\u3051\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002\u3057\u304b\u3057\u3001<strong>Figure 2<\/strong>\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001Rxi-SVOCms\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u4e00\u8cab\u3057\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u304c\u5b9f\u73fe\u3055\u308c\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u5b89\u5b9a\u3057\u305f\u6821\u6b63\u306b\u3088\u308a\u3001\u518d\u6821\u6b63\u306e\u983b\u5ea6\u304c\u6291\u3048\u3089\u308c\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u9593\u304c\u5897\u52a0\u3059\u308b\u306e\u3067\u3001\u751f\u7523\u6027\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u7dd1\u306f\u521d\u671f\u6821\u6b63\u306b\u5408\u683c\u3057\u305f\u3053\u3068\u3092\u793a\u3057\u307e\u3059\uff08n = 6\u30ab\u30e9\u30e0\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5316\u5408\u7269<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u6821\u6b63\u7bc4\u56f2 (\u00b5g\/mL)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30ec\u30b9\u30dd\u30f3\u30b9\u30d5\u30a1\u30af\u30bf\u30fc\u306e\u5e73\u5747\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u3000<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">N-Nitrosodimethylamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pyridine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) 2-Fluorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) Phenol-d6<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Phenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Aniline<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bis(2-chloroethyl)ether<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-chlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,3-dichlorobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,4-Dichlorobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzyl alcohol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,2-Dichlorobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-Methylphenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bis(2-chloroisopropyl)ether<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Methylphenol\/3-methylphenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">N-nitroso-di-<em>n<\/em>-propylamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hexachloroethane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.00%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) Nitrobenzene-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Nitrobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Isophorone<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-Nitrophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.00%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4-Dimethylphenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzoic acid<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.5 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>25.00%<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bis(2-chloroethoxy)methane<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4-Dichlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,2,4-Trichlorobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Naphthalene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Chloroaniline<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hexachlorobutadiene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Chloro-3-methylphenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-Methylnaphthalene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1-Methylnaphthalene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hexachlorocyclopentadiene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4,6-Trichlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4,5-Trichlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) 2-Fluorobiphenyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-Chloronaphthalene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2-Nitroaniline<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,4-Dinitrobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">11.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dimethyl phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,3-Dinitrobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,6-Dinitrotoluene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Acenaphthylene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1,2-Dinitrobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3-Nitroaniline<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Acenaphthene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4-Dinitrophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.5 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">17.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Nitrophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dibenzofuran<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,4-Dinitrotoluene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">11.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,3,5,6-Tetrachlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2,3,4,6-Tetrachlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Diethyl phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Chlorophenyl phenyl ether<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Fluorene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Nitroaniline<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4,6-Dinitro-2-methylphenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.5 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">15.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">N-nitrosodiphenylamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Diphenylhydrazine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) 2,4,6-Tribromophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Bromophenyl phenyl ether<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hexachlorobenzene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pentachlorophenol<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Phenanthrene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Anthracene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Carbazole<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">di-<em>n<\/em>-Butyl phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Fluoranthene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.10%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzidine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS) Pyrene-D10<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pyrene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">(SS)&nbsp;<em>p<\/em>-Terphenyl-d14<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.80%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3,3&#8242;-Dimethylbenzidine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">9.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Butyl benzyl phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bis(2-ethylhexyl)adipate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3,3&#8242;-Dichlorobenzidine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benz[a]anthracene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Chrysene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.70%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bis(2-ethylhexyl)phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">10.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Di-<em>n<\/em>-octyl phthalate<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">13.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzo[b]fluoranthene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.60%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzo[k]fluoranthene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.90%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzo[a]pyrene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.30%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Indeno[123-cd]pyrene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.20%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dibenz[a,h]anthracene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.50%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzo[ghi]perylene<\/td><td class=\"has-text-align-center\" data-align=\"center\">1 &#8211; 120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.40%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>%RSD\u306e\u5e73\u5747<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>6.00%<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044Rxi-SVOCms\u30ab\u30e9\u30e0\u306a\u3089\u3001\u30d4\u30ea\u30b8\u30f3Pyridine\uff08\u5869\u57fa\u6027\u30a2\u30df\u30f3\uff09\u3084\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30ebPentachlorophenol\uff08\u9178\u6027\u30d5\u30a7\u30ce\u30fc\u30eb\uff09\u306e\u3088\u3046\u306a\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u3084\u3059\u3044\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u304c\u4f4e\u6fc3\u5ea6\u3067\u3042\u3063\u3066\u3082\u3001\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.png\" alt=\"Balanced Rxi-SVOCms Column Chemistry Produces Symmetrical Peaks and Stable Retention Times as Mass on Column Varies\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1605<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5805\u7262\u3067\u9577\u5bff\u547d\u306eRxi-SVOCms\u30ab\u30e9\u30e0\u3067\u7c21\u5358\u306b\u6821\u6b63\u6027\u80fd\u3092\u56de\u5fa9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u5206\u6790\u306e\u73fe\u5834\u3067\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u5316\u5b66\u7269\u8cea\u304c\u542b\u307e\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u304c\u983b\u7e41\u306b\u53d6\u308a\u6271\u308f\u308c\u3001\u305d\u306e\u6210\u5206\u306e\u8907\u96d1\u3055\u306f\u30ab\u30e9\u30e0\u306b\u8ca0\u62c5\u3092\u304b\u3051\u308b\u539f\u56e0\u3068\u306a\u308a\u307e\u3059\u3002\u7279\u306b\u3001\u5316\u5b66\u7269\u8cea\u304c\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3059\u308b\u3053\u3068\u304c\u61f8\u5ff5\u3055\u308c\u307e\u3059\u304c\u3001\u305d\u308c\u304c\u5fc5\u305a\u3057\u3082\u30ab\u30e9\u30e0\u306e\u52a3\u5316\u306b\u76f4\u7d50\u3059\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002Rxi-SVOCms\u30ab\u30e9\u30e0\u306e\u5185\u90e8\u69cb\u9020\u3084\u56fa\u5b9a\u76f8\u306f\u3001\u6539\u826f\u3055\u308c\u3066\u304a\u308a\u3001\u975e\u5e38\u306b\u904e\u9177\u306a\u6761\u4ef6\u4e0b\u3067\u3082\u6027\u80fd\u3092\u4fdd\u3064\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<strong>Figure 3<\/strong>\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001\u6c5a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u7e70\u308a\u8fd4\u3057\u6ce8\u5165\u3057\u306a\u304c\u3089\u30ab\u30e9\u30e0\u306e\u6821\u6b63\u6027\u80fd\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3057\u305f\u7d50\u679c\u300130\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u3054\u3068\u306b\u6c5a\u67d3\u3055\u308c\u305f\u7b87\u6240\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u3001300\u56de\u306e\u6ce8\u5165\u5f8c\u3067\u3082\u6821\u6b63\u6027\u80fd\u304c\u56de\u5fa9\u3059\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002300\u56de\u306e\u6ce8\u5165\u5f8c\u306b\u304a\u3051\u308b\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u30c1\u30a7\u30c3\u30af\u3067\u3001\u4e0d\u5408\u683c\u3068\u306a\u308b\u5316\u5408\u7269\u306f\u308f\u305a\u304b10%\u672a\u6e80\u3067\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30ab\u30e9\u30e0\u306e\u8010\u4e45\u6027\u3068\u5b89\u5b9a\u6027\u3092\u8a3c\u660e\u3059\u308b\u3082\u306e\u3067\u3042\u308a\u3001\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u975e\u5e38\u306b\u7c21\u5358\u3067\u3042\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u7c21\u5358\u306a\u30c8\u30ea\u30df\u30f3\u30b0\u3068\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u30c1\u30a7\u30c3\u30af\u3060\u3051\u3067\u3001\u30ab\u30e9\u30e0\u306f\u518d\u3073\u5143\u306e\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u5927\u5e45\u306b\u524a\u6e1b\u3057\u3001\u30ab\u30e9\u30e0\u4ea4\u63db\u306e\u983b\u5ea6\u3082\u4f4e\u304f\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u5168\u4f53\u7684\u306a\u4f5c\u696d\u52b9\u7387\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> \u30ab\u30e9\u30e0\u306e\u6027\u80fd\u306f\u3001\u975e\u5e38\u306b\u8907\u96d1\u306a\u30b5\u30f3\u30d7\u30eb\u306b\u7e70\u308a\u8fd4\u3057\u66dd\u9732\u3057\u305f\u5f8c\u3067\u3042\u3063\u3066\u3082\u3001\u30c8\u30ea\u30df\u30f3\u30b0\u306b\u3088\u3063\u3066\u5b8c\u5168\u306b\u56de\u5fa9\u3057\u307e\u3059\u3002\u5805\u7262\u306a Rxi-SVOCms \u30ab\u30e9\u30e0\u306f\u3001\u30ab\u30e9\u30e0\u306e\u4ea4\u63db\u3084\u518d\u6821\u6b63\u3092\u884c\u3046\u3053\u3068\u306a\u304f\u3001\u7d99\u7d9a\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u304c\u53ef\u80fd\u3067\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\"><em><u>300\u30b5\u30f3\u30d7\u30eb\u306e\u8010\u4e45\u6027\u8a66\u9a13 \u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3<\/u><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u30c7\u30a3\u30fc\u30bc\u30eb\u5fae\u7c92\u5b50\u62bd\u51fa\u7269\uff08NIST SRM 1975\uff09\u30921\u65e530\u56de\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u30b5\u30f3\u30d7\u30eb\u309210\u56de\u6ce8\u5165\u3059\u308b\u3054\u3068\u306b\u7d99\u7d9a\u6821\u6b63\u691c\u8a3c\uff08CCV\uff09\u7528\u6a19\u6e96\u6eb6\u6db2\u3092\u6ce8\u5165\u3057\u307e\u3057\u305f\u30023\u56de\u76ee\u306eCCV\u7528\u6a19\u6e96\u6eb6\u6db2\u6ce8\u5165\u5f8c\u3001\u30ab\u30e9\u30e0\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3057\u3001\u30e9\u30a4\u30ca\u30fc\u3001\u30bb\u30d7\u30bf\u30e0\u3001\u6ce8\u5165\u53e3\u30b7\u30fc\u30eb\u3092\u4ea4\u63db\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u309210\u65e5\u9593\u7e70\u308a\u8fd4\u3057\u305f\u5f8c\u30012\u672c\u76ee\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u3063\u3066\u5b9f\u9a13\u5168\u4f53\u3092\u7e70\u308a\u8fd4\u3057\u307e\u3057\u305f\u3002<\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em><strong>\u9752\u3044\u7dda<\/strong>\u306f\u3001\u3059\u3079\u3066\u306eCCV\u7528\u6a19\u6e96\u6eb6\u6db2\u6ce8\u5165\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u307e\u305a\u6027\u80fd\u304c\u4f4e\u4e0b\u3057\uff08\u3053\u308c\u306f\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308a\u4e88\u60f3\u3055\u308c\u305f\u901a\u308a\u3067\u3059\uff09\u3001\u305d\u306e\u5f8c\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u3088\u308a\u5b8c\u5168\u306b\u56de\u5fa9\u3057\u305f\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/em><\/li>\n\n\n\n<li><em><strong>\u7dd1\u306e\u7dda<\/strong>\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u5f8c\u306eCCV\u7528\u6a19\u6e96\u6eb6\u6db2\u6ce8\u5165\u306e\u307f\u3092\u30d7\u30ed\u30c3\u30c8\u3057\u305f\u3082\u306e\u3067\u3001\u6821\u6b63\u6027\u80fd\u306e\u5b89\u5b9a\u6027\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/em><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"742\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu-1024x742.png\" alt=\"\" class=\"wp-image-19749\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu-1024x742.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu-300x217.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu-768x556.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu-1536x1113.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-jpsuzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u3059\u3079\u3066\u306eRxi-SVOCms\u30ab\u30e9\u30e0\u304c\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eRxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306b\u958b\u767a\u3055\u308c\u305f\u5316\u5b66\u7684\u7279\u6027\u3092\u6301\u3064\u30dd\u30ea\u30de\u30fc\u3092\u7528\u3044\u3066\u88fd\u9020\u3055\u308c\u3001\u305d\u306e\u904e\u7a0b\u306b\u304a\u3044\u3066\u306f\u6700\u3082\u53b3\u683c\u306a\u54c1\u8cea\u7ba1\u7406\u3068\u30c6\u30b9\u30c8\u304c\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5fb9\u5e95\u7684\u306a\u88fd\u9020\u7ba1\u7406\u306b\u3088\u308a\u3001\u3059\u3079\u3066\u306eRxi-SVOCms\u30ab\u30e9\u30e0\u306f\u6975\u3081\u3066\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u3001\u5e38\u306b\u4e00\u5b9a\u306e\u5206\u6790\u7d50\u679c\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u30012,4-\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u3088\u3046\u306a\u9ad8\u3044\u6d3b\u6027\u5ea6\u3092\u6301\u3061\u3001\u3057\u3070\u3057\u3070\u5206\u6790\u306e\u969b\u306b\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3059\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u3001\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u6e2c\u5b9a\u7d50\u679c\u306e\u3070\u3089\u3064\u304d\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002Rxi-SVOCms\u30ab\u30e9\u30e0\u306e\u3082\u3046\u4e00\u3064\u306e\u9855\u8457\u306a\u7279\u5fb4\u306f\u3001\u6975\u3081\u3066\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3067\u3059\u3002Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u305d\u306e\u8a2d\u8a08\u306b\u3088\u308a\u3001\u30d6\u30ea\u30fc\u30c9\u304c\u975e\u5e38\u306b\u5c11\u306a\u3044\u305f\u3081\u3001\u5e72\u6e09\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30af\u30ea\u30fc\u30f3\u3067\u6b63\u78ba\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<strong>Figure 4<\/strong>\u306b\u793a\u3055\u308c\u305f\u3088\u3046\u306b\u3001\u3053\u308c\u3089\u306e\u7279\u5fb4\u304c\u76f8\u4e57\u52b9\u679c\u3092\u751f\u307f\u3001\u975e\u5e38\u306b\u9ad8\u3044\u7cbe\u5ea6\u3067\u5206\u6790\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> \u3059\u3079\u3066\u306eRxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3068\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u5b9f\u73fe\u3059\u308b\u306e\u3067\u3001\u3069\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3082\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u6027\u80fd\u3092\u793a\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002\u3000<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.png\" alt=\"Rxi-SVOCms Column-to-Column Reproducibility\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1215<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23305<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u74b0\u5883\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\u5316\u5408\u7269\u3092\u78ba\u5b9f\u306b\u5206\u96e2<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAH\uff09\u306f\u3001\u7279\u306b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5206\u96e2\u304c\u6700\u3082\u96e3\u3057\u3044\u5316\u5408\u7269\u306e\u4e00\u3064\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u975e\u5e38\u306b\u4f3c\u305f\u5316\u5b66\u7684\u7279\u6027\u3092\u6301\u3063\u3066\u304a\u308a\u3001\u5fae\u91cf\u30ec\u30d9\u30eb\u3067\u6b63\u78ba\u306a\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u96a3\u63a5\u3057\u3066\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3067\u304d\u308b\u9ad8\u3044\u9078\u629e\u6027\u3068\u52b9\u7387\u3092\u5099\u3048\u305f\u30ab\u30e9\u30e0\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<strong>Figure 5<\/strong>\u306b\u793a\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30ab\u30e9\u30e0\u306f\u30d9\u30f3\u30be[b]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3068\u30d9\u30f3\u30be[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3068\u3044\u3063\u305f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u3067\u5206\u96e2\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5316\u5408\u7269\u3092\u542b\u308023\u306e\u512a\u5148\u6c5a\u67d3\u7269\u8cea\u306e\u5206\u96e2\u3092\u6700\u9069\u5316\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001MS\u5358\u4f53\u3067\u306f\u533a\u5225\u3067\u304d\u306a\u3044\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u306a\u540c\u91cd\u4f53\u3092\u542b\u3080\u3001\u96a3\u63a5\u3057\u3066\u6eb6\u51fa\u3059\u308b\u512a\u5148PAH\u6c5a\u67d3\u7269\u8cea\u306e\u5206\u96e2\u3092\u6700\u9069\u5316\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.png\" alt=\"Priority PAH Pollutants on Rxi-SVOCms (SIM)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1609<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PAH<\/li><li>aromatic<\/li><li>hydrocarbons<\/li><li>polycyclic<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">                                \u30ab\u30bf\u30ed\u30b0No. 16623                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                \u30ab\u30bf\u30ed\u30b0No. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SVOC MegaMix 150 Kit, 1 mL\/ampul; 6 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31908\">                                \u30ab\u30bf\u30ed\u30b0No. 31908                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SVOC MegaMix 100 Kit: 1 mL\/ampul; 3 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31908\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31850\">                                \u30ab\u30bf\u30ed\u30b0No. 31850                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">8270 MegaMix Standard, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31850\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31852\">                                \u30ab\u30bf\u30ed\u30b0No. 31852                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">8270 Benzidines Mix, 2000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31852\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31879\">                                \u30ab\u30bf\u30ed\u30b0No. 31879                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Benzoic Acid, 2000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31879\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                \u30ab\u30bf\u30ed\u30b0No. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised SV Internal Standard Mix, 4000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31888\">                                \u30ab\u30bf\u30ed\u30b0No. 31888                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised B\/N Surrogate Mix, 5000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31888\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31063\">                                \u30ab\u30bf\u30ed\u30b0No. 31063                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Acid Surrogate Mix (4\/89 SOW), 10,000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31063\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                \u30ab\u30bf\u30ed\u30b0No. 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21782\">                                \u30ab\u30bf\u30ed\u30b0No. 21782                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/ Bottom Spring, 50 \u00b5L, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21782\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23842\">                                \u30ab\u30bf\u30ed\u30b0No. 23842                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Caps, Polypropylene, Ribbed, Screw-Thread, PTFE\/Silicone Lined, for Agilent 7693A, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23842\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Rxi-SVOCms\u30ab\u30e9\u30e0\u306f\u3001\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u9ad8\u7cbe\u5ea6\u306a\u5206\u6790\u3068\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAH\uff09\u306e\u512a\u308c\u305f\u5206\u96e2\u6027\u80fd\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u5b89\u5b9a\u3057\u305f\u518d\u73fe\u6027\u3068\u4f4e\u30d6\u30ea\u30fc\u30c9\u7279\u6027\u306b\u3088\u308a\u3001\u9577\u5bff\u547d\u3092\u8a87\u308a\u3001\u74b0\u5883\u5206\u6790\u306e\u52b9\u7387\u3092\u98db\u8e8d\u7684\u306b\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002\u983b\u7e41\u306a\u6821\u6b63\u3084\u30ab\u30e9\u30e0\u4ea4\u63db\u3092\u5fc5\u8981\u3068\u305b\u305a\u3001\u5206\u6790\u4f5c\u696d\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":25647,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2668,2271,2287],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340,2345],"ppma_author":[414],"class_list":["post-43530","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-semivolatiles","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2668,"label":"Semivolatiles"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/header-article-EVSS3820-1024x466.jpg",1024,466,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43530"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43530\/revisions"}],"predecessor-version":[{"id":79119,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43530\/revisions\/79119"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/25647"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43530"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43530"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43530"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43530"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43530"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43530"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43530"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43530"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}