{"id":43533,"date":"2025-10-03T21:19:37","date_gmt":"2025-10-03T21:19:37","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/exceptionally-clean-resins-for-air-analysis-japan\/"},"modified":"2025-11-24T23:47:24","modified_gmt":"2025-11-24T23:47:24","slug":"exceptionally-clean-resins-for-air-analysis-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evss4390-ja\/exceptionally-clean-resins-for-air-analysis-japan","title":{"rendered":"\u5927\u6c17\u5206\u6790\u306b\u6700\u9069\u306a\u3001\u8d85\u9ad8\u6e05\u6d44\u5ea6\u3092\u6301\u30642\u3064\u306eSDVB\u5438\u7740\u5264"},"content":{"rendered":"\n<p><strong>\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dSDVB\u5438\u7740\u5264\u3000Rezin\u306e\u7279\u9577<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5727\u5012\u7684\u306b\u30af\u30ea\u30fc\u30f3 <\/strong>\u30fc&nbsp;\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAHs\uff09\u3001\u8fb2\u85ac\u3001PCBs\u3001\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u3001PFAS\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u3092\u5fb9\u5e95\u7684\u306b\u6291\u3048\u307e\u3057\u305f\u3002<\/li>\n\n\n\n<li><strong>TO-13\u306b\u5bfe\u5fdc<\/strong> \u30fc EPA Method TO-13\u3067\u6c42\u3081\u3089\u308c\u308bPAHs\u6b8b\u7559\u57fa\u6e96\u3092\u30af\u30ea\u30a2\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u4f7f\u3044\u3084\u3059\u3055<\/strong> \u2015 \u512a\u308c\u305f\u7c92\u5b50\u6d41\u52d5\u6027\u304c\u5b9f\u73fe\u3055\u308c\u305f\u305f\u3081\u7c92\u5b50\u306e\u584a\u304c\u3067\u304d\u305a\u3001\u6b63\u78ba\u3067\u30b9\u30e0\u30fc\u30ba\u306a\u53d6\u308a\u6271\u3044\u304c\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u5927\u6c17\u5206\u6790\u306e\u5c02\u9580\u5bb6\u304c\u958b\u767a\u3057\u305f\u30ec\u30b8\u30f3\u5438\u7740\u5264\u30b7\u30ea\u30fc\u30ba<\/h2>\n\n\n\n<p>\u5927\u6c17\u5206\u6790\u306b\u304a\u3044\u3066\u6c42\u3081\u3089\u308c\u308b\u306e\u306f\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u3092\u5fb9\u5e95\u7684\u306b\u6291\u3048\u308b\u3053\u3068\u3067\u3059\u304c\u3001\u958b\u5c01\u3057\u3066\u305d\u306e\u307e\u307e\u4f7f\u3048\u308b\u3068\u3044\u3046\u70b9\u3082\u91cd\u8981\u3067\u3059\u3002\u30b9\u30c1\u30ec\u30f3\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08SDVB\uff09\u6a39\u8102\u3092\u4f7f\u7528\u3059\u308b\u969b\u306b\u3001\u5927\u6c17\u5206\u6790\u30e9\u30dc\u306f\u3044\u304f\u3064\u304b\u306e\u8ab2\u984c\u306b\u76f4\u9762\u3057\u307e\u3059\u3002Restek\u306e\u5927\u6c17\u5206\u6790\u5c02\u9580\u30b1\u30df\u30b9\u30c8\u306f\u3001\u3053\u3053\u306b\u6ce8\u76ee\u3057\u307e\u3057\u305f\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u304a\u3051\u308b\u6570\u5341\u5e74\u306e\u7d4c\u9a13\u306b\u3088\u308a\u3001\u5927\u6c17\u5206\u6790\u30e9\u30dc\u306e\u30cb\u30fc\u30ba\u3092\u6e80\u305f\u3059\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u305f2\u3064\u306e\u30ec\u30b8\u30f3\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin SDVB\u5438\u7740\u5264<\/h3>\n\n\n\n<p>Rezin\u306f\u3001\u5727\u5012\u7684\u306a\u6e05\u6d44\u5ea6\u3092\u6301\u3064\u30d7\u30ec\u30df\u30a2\u30e0SDVB\u5438\u7740\u5264\u3067\u3059\u3002\u5927\u6c17\u5206\u6790\u5c02\u9580\u30b1\u30df\u30b9\u30c8\u304c\u65b0\u305f\u306b\u8a2d\u8a08\u3057\u305f\u72ec\u81ea\u306e\u6d17\u6d44\u65b9\u6cd5\u306b\u3088\u308a\u3001PAHs\u3001\u8fb2\u85ac\u3001PCB\u3001PFAS\u3001\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u306a\u3069\u306e\u6c5a\u67d3\u7269\u8cea\u306b\u3088\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u3092\u5fb9\u5e95\u7684\u306b\u6291\u3048\u305f\u6a39\u8102\u88fd\u9020\u306b\u6210\u529f\u3057\u307e\u3057\u305f\u3002Rezin\u5438\u7740\u5264\u306f\u3001EPA Method TO-13\u3067\u5fc5\u8981\u3068\u3055\u308c\u3066\u3044\u308bPAH\u6b8b\u7559\u57fa\u6e96\u3092\u30af\u30ea\u30a2\u3057\u307e\u3059\u3002\u5206\u6790\u8a3c\u660e\u66f8\u4ed8\u304d\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3059\u3088\u3046\u306b\u3001\u3053\u306e\u898f\u5b9a\u8981\u4ef6\u3092\u78ba\u5b9f\u306b\u6e80\u305f\u3059\u6027\u80fd\u304c\u4fdd\u8a3c\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u3055\u3089\u306b\u3001Rezin\u5438\u7740\u5264\u306f\u3001\u30dc\u30c8\u30eb\u304b\u3089\u53d6\u308a\u51fa\u3057\u3066\u305d\u306e\u307e\u307e\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u7279\u5225\u306b\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u591a\u304f\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u8ffd\u52a0\u306e\u6d17\u6d44\u304c\u4e0d\u8981\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3064\u307e\u308a\u3001\u30e9\u30dc\u306e\u30b3\u30b9\u30c8\u3068\u6642\u9593\u3092\u524a\u6e1b\u3059\u308b\u3053\u3068\u3082\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/27242\" target=\"_blank\" rel=\"noreferrer noopener\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS4390-product-bottle.png\" alt=\"A bottle of Rezin Certified Clean SDVB Resin.\" title=\"-\"><\/a><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Clean SDVB\u30ec\u30b8\u30f3<\/h3>\n\n\n\n<p>Clean SDVB\u30ec\u30b8\u30f3\u306f\u3001\u5927\u6c17\u4e2dSVOC\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u6700\u9069\u3067\u3001\u30b3\u30b9\u30c8\u3092\u6291\u3048\u3066\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u3092\u884c\u3044\u305f\u3044\u30e9\u30dc\u306b\u6700\u9069\u3067\u3059\u3002Restek\u306e\u30d7\u30ec\u30df\u30a2\u30e0Rezin\u5438\u7740\u5264\u3068\u540c\u3058SDVB\u57fa\u6750\u3092\u4f7f\u7528\u3057\u305fClean SDVB\u30ec\u30b8\u30f3\u306f\u3001\u5fb9\u5e95\u3057\u305f\u6d17\u6d44\u3068\u30ac\u30b9\u30d1\u30fc\u30b8\u3092\u884c\u3063\u305f\u5f8c\u306b\u30dc\u30c8\u30eb\u8a70\u3081\u3055\u308c\u307e\u3059\u3002Rezin\u5438\u7740\u5264\u307b\u3069\u306e\u9ad8\u3044\u6e05\u6d44\u5ea6\u3068\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u306e\u4f4e\u3055\u304c\u5fc5\u8981\u3068\u3055\u308c\u3066\u3044\u306a\u3044\u306a\u3089\u3001\u305d\u306e\u5206\u6790\u306b\u306fClean SDVB\u30ec\u30b8\u30f3\u304c\u6700\u9069\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b89\u5b9a\u3057\u3066\u5353\u8d8a\u3057\u305f\u6e05\u6d44\u5ea6<\/h2>\n\n\n\n<p>\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin SDVB\u5438\u7740\u5264\u3068Clean SDVB\u30ec\u30b8\u30f3\u306f\u3069\u3061\u3089\u3082\u3001\u5927\u6c17\u4e2d\u306e\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAHs\uff09\u3001\u8fb2\u85ac\u3001PCBs\u3001PFAS\u3001\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u306a\u3069\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u8a66\u6599\u3092\u63a1\u53d6\u3059\u308b\u305f\u3081\u306b\u3001\u5927\u6c17\u3084\u6392\u30ac\u30b9\u306e\u30a2\u30af\u30c6\u30a3\u30d6\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u7528\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002EPA Method TO-13\u3084OTM-45\u306e\u3088\u3046\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u65b9\u6cd5\u306b\u4f7f\u7528\u3055\u308c\u308b\u5834\u5408\u3001\u901a\u5e38\u3001\u6d17\u6d44\u3055\u308c\u305f\u30ec\u30b8\u30f3\u304c\u30ac\u30e9\u30b9\u88fd\u30db\u30eb\u30c0\u30fc\u306b\u5165\u308c\u3089\u308c\u3001\u6d17\u6d44\u3055\u308c\u305f\u30dd\u30ea\u30a6\u30ec\u30bf\u30f3\u30d5\u30a9\u30fc\u30e0\u30d7\u30e9\u30b0\u307e\u305f\u306f\u30ac\u30e9\u30b9\u30d5\u30ea\u30c3\u30c8\u3067\u56fa\u5b9a\u3055\u308c\u307e\u3059\u3002\u4e00\u5b9a\u6642\u9593\u3001\u771f\u7a7a\u30dd\u30f3\u30d7\u3092\u4f7f\u3063\u3066\u30ec\u30b8\u30f3\u306b\u30a8\u30a2\u30fc\u3092\u901a\u3057\u3001\u305d\u306e\u5f8c\u30ec\u30b8\u30f3\u3092\u30db\u30eb\u30c0\u30fc\u304b\u3089\u53d6\u308a\u5916\u3057\u3066\u62bd\u51fa\u3057\u307e\u3059\u3002\u62bd\u51fa\u6db2\u306f\u5206\u6790\u7528\u306b\u8abf\u6574\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p>Restek SDVB\u5438\u7740\u5264\u306e\u7269\u7406\u7684\u7279\u6027\u306fXAD-2\u30ec\u30b8\u30f3\u3068\u540c\u7b49\u3067\u3059\uff08<strong>Table I<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<p><strong>Table I:<\/strong> Restek\u306eSDVB\u5438\u7740\u5264\u306e\u7269\u7406\u7684\u7279\u6027<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u7c92\u5b50\u30d1\u30e9\u30e1\u30fc\u30bf<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u57fa\u6e96<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u7c92\u5ea6\u5206\u5e03<\/td><td class=\"has-text-align-left\" data-align=\"left\">20-60 mesh<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e73\u5747\u8868\u9762\u7a4d (m<sup>2<\/sup>\/g)\u3000<\/td><td class=\"has-text-align-left\" data-align=\"left\">350-360<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e73\u5747\u5bc6\u5ea6 (g\/mL)\u3000<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.10-1.15<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e73\u5747\u7d30\u5b54\u76f4\u5f84 (\u00c5)\u3000<\/td><td class=\"has-text-align-left\" data-align=\"left\">90-100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5e73\u5747\u7d30\u5b54\u5bb9\u7a4d (mL\/g)\u3000<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.65 +\/- 0.1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>SDVB\u5438\u7740\u5264\u306b\u306f\u305d\u306e\u88fd\u9020\u904e\u7a0b\u3067\u306e\u6b8b\u7559\u7269\u304c\u591a\u3044\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u6eb6\u5264\u3092\u7528\u3044\u305f\u6d17\u6d44\u304c\u5fc5\u8981\u3067\u3059\u3002\u691c\u67fb\u3055\u308c\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u3088\u3063\u3066\u3001\u6d17\u6d44\u65b9\u6cd5\u3068\u8a31\u5bb9\u3055\u308c\u308b\u6b8b\u7559\u57fa\u6e96\u306f\u5909\u308f\u308a\u307e\u3059\u3002SDVB\u5438\u7740\u5264\u306b\u306f\u30ca\u30d5\u30bf\u30ec\u30f3\u3084\u305d\u306e\u4ed6\u306ePAHs\u304c\u9ad8\u6fc3\u5ea6\u3067\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002EPA Method TO-13\u306a\u3069\u306e\u30e1\u30bd\u30c3\u30c9\u304c\u6c42\u3081\u308b\u57fa\u6e96\u307e\u3067\u3001\u3053\u308c\u3089\u306e\u7269\u8cea\u3092\u9664\u53bb\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002Restek\u306eRezin\u5438\u7740\u5264\u306f\u3001EPA Method TO-13\u306e\u8981\u4ef6\u304c\u6c42\u3081\u308b\u6b8b\u7559\u57fa\u6e96\uff08<strong>Table II<\/strong>\u53c2\u7167\uff09\u3092\u6e80\u305f\u3059\u304b\u3001\u305d\u308c\u3092\u4e0a\u56de\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u8a3c\u660e\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p><strong>Table II:<\/strong> \u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304d\u5438\u7740\u5264Rezin\u306e\u5206\u6790\u8a3c\u660e\u66f8\u304b\u3089\u306e\u629c\u7c8b<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u691c\u67fb\u5bfe\u8c61<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u57fa\u6e96*<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u7d50\u679c<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30ca\u30d5\u30bf\u30ec\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;750 ppb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5408\u683c<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u305d\u306e\u4ed6\u306ePAHs<sup>\u2020\u3000<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt;150 ppb each<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5408\u683c<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><sup>\u2020<\/sup>Acenaphthene, Acenaphthylene, Anthracene, Benz[a]anthracene, Benzo[a]pyrene, Benzo[b]fluoranthene, Benzo[g,h,i]perylene, Benzo[k]fluoranthene, Chrysene, Dibenz[a,h]anthracene, Fluoranthene, Fluorene, Indeno[1,2,3-cd]pyrene, 1-Methylnaphthalene, 2-Methylnaphthalene, Phenanthrene, Pyrene\uff08\u30a2\u30bb\u30ca\u30d5\u30c6\u30f3\u3001\u30a2\u30bb\u30ca\u30d5\u30c1\u30ec\u30f3\u3001\u30a2\u30f3\u30c8\u30e9\u30bb\u30f3\u3001\u30d9\u30f3\u30be[a]\u30a2\u30f3\u30c8\u30e9\u30bb\u30f3\u3001\u30d9\u30f3\u30be[a]\u30d4\u30ec\u30f3\u3001\u30d9\u30f3\u30be[b]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3001\u30d9\u30f3\u30be[g,h,i]\u30da\u30ea\u30ec\u30f3\u3001\u30d9\u30f3\u30be[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3001\u30af\u30ea\u30bb\u30f3\u3001\u30b8\u30d9\u30f3\u30be[a,h]\u30a2\u30f3\u30c8\u30e9\u30bb\u30f3\u3001\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3001\u30d5\u30eb\u30aa\u30ec\u30f3\u3001\u30a4\u30f3\u30c7\u30ce[1,2,3-cd]\u30d4\u30ec\u30f3\u30011-\u30e1\u30c1\u30eb\u30ca\u30d5\u30bf\u30ec\u30f3\u30012-\u30e1\u30c1\u30eb\u30ca\u30d5\u30bf\u30ec\u30f3\u3001\u30d5\u30a7\u30ca\u30f3\u30c8\u30ec\u30f3\u3001\u30d4\u30ec\u30f3\uff09<\/p>\n\n\n\n<p>\u6d17\u6d44\u3057\u305f\u30ec\u30b8\u30f3\u306e\u6b8b\u7559\u6fc3\u5ea6\u306f\u3001\u7279\u5b9a\u306e\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u65b9\u6cd5\u3067\u5bfe\u8c61\u3068\u3057\u3066\u3044\u308b\u6210\u5206\u306b\u3064\u3044\u3066\u306f\u8a31\u5bb9\u7bc4\u56f2\u5185\u3067\u3042\u3063\u305f\u3068\u3057\u3066\u3082\u3001\u5225\u306e\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u65b9\u6cd5\u3067\u5bfe\u8c61\u3068\u306a\u308b\u4ed6\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u306e\u6b8b\u7559\u304c\u78ba\u8a8d\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3055\u3089\u306a\u308b\u6d17\u6d44\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3088\u308a\u4f4e\u3044\u691c\u51fa\u9650\u754c\u3092\u5fc5\u8981\u3068\u3059\u308b\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u306f\u3001Clean SDVB\u30ec\u30b8\u30f3\u3084\u4ed6\u306e\u30ec\u30b8\u30f3\u306b\u6bd4\u3079\u3066\u6b8b\u7559\u7269\u304c\u5927\u5e45\u306b\u4f4e\u6e1b\u3055\u308c\u3066\u3044\u308b\u3001\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin SDVB\u5438\u7740\u5264\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u5206\u6790\u306b\u3088\u308a\u307e\u3059\u304c\u3001Restek\u306eRezin\u5438\u7740\u5264\u306f\u30dc\u30c8\u30eb\u304b\u3089\u53d6\u308a\u51fa\u3057\u3066\u3059\u3050\u306b\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u306b\u88fd\u9020\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3082\u3057\u6d17\u6d44\u304c\u5fc5\u8981\u3067\u3042\u3063\u305f\u3068\u3057\u3066\u3082\u3001\u4ed6\u306e\u30ec\u30b8\u30f3\u306b\u6bd4\u3079\u3066\u6d17\u6d44\u306e\u624b\u9593\u306f\u304b\u304b\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p>PFAS\u5316\u5408\u7269\u306f\u74b0\u5883\u4e2d\u306b\u5e83\u304f\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u5fae\u91cf\u30ec\u30d9\u30eb\u306e\u5206\u6790\u304c\u6c42\u3081\u3089\u308c\u30b1\u30fc\u30b9\u3082\u5897\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u6d17\u6d44\u3057\u305f\u30ec\u30b8\u30f3\u306bPFAS\u304c\u30b3\u30f3\u30bf\u30df\u3057\u306a\u3044\u3088\u3046\u3001\u7279\u5225\u306a\u53d6\u308a\u6271\u3044\u304c\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u5fdc\u3057\u3001Restek\u306eRezin\u5438\u7740\u5264\u306f\u3001\u5927\u6c17\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u6e2c\u5b9a\u306b\u95a2\u3059\u308bTO-13\u898f\u683c\u3067\u6c42\u3081\u3089\u308c\u308b\u54c1\u8cea\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3088\u3046\u8a2d\u8a08\u30fb\u7ba1\u7406\u3057\u3001\u305d\u306e\u898f\u683c\u306b\u6e96\u62e0\u3057\u305fQC\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3066\u3044\u307e\u3059\u3002\u306a\u304a\u3001\u901a\u5e38\u306eQC\u8a66\u9a13\u9805\u76ee\u306b\u306f\u542b\u307e\u308c\u3066\u3044\u306a\u3044PFAS\u3084PCB\u3001\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u985e\u306a\u3069\u306e\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u306f\u3001\u53c2\u8003\u8a66\u9a13\u3068\u3057\u3066\u6b8b\u7559\u7269\u691c\u67fb\u3092\u5b9f\u65bd\u3057\u305f\u7d50\u679c\u3001\u5bfe\u8c61\u6210\u5206\u306e\u307b\u3068\u3093\u3069\u306f\u691c\u51fa\u9650\u754c\u672a\u6e80\u3001\u307e\u305f\u306f\u691c\u51fa\u3055\u308c\u305f\u5834\u5408\u3067\u3082\u975e\u5e38\u306b\u4f4e\u6fc3\u5ea6\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6bd4\u985e\u306a\u3044\u5727\u5012\u7684\u306a\u6e05\u6d44\u5ea6<\/h2>\n\n\n\n<p>\u4ed6\u793e\u88fd\u9020\u306e\u6d17\u6d44\u3055\u308c\u305fXAD\u985e\u4f3c\u30ec\u30b8\u30f3\u3092\u3054\u4f7f\u7528\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u3044\u304f\u3064\u304b\u306e\u5316\u5408\u7269\u306b\u95a2\u3057\u3066\u306f\u3001Restek\u30ec\u30b8\u30f3\u5438\u7740\u5264\u3068\u6bd4\u8f03\u3057\u3066\u8457\u3057\u304f\u9ad8\u3044\u6b8b\u7559\u6fc3\u5ea6\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\uff08<strong>Table III<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<p><strong>Table III:<\/strong> \u5727\u5012\u7684\u306a\u6e05\u6d44\u5ea6\u304c\u3082\u305f\u3089\u3059\u5353\u8d8a\u3057\u305f\u6027\u80fd<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td colspan=\"2\"><strong>Restek<\/strong><\/td><td colspan=\"3\"><strong>\u7af6\u5408\u4ed6\u793eA<\/strong><\/td><\/tr><tr><td>&nbsp;<\/td><td>\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin SDVB\u5438\u7740\u5264 (ppb)\u3000<\/td><td>Ultra-Clean\u30ec\u30b8\u30f3 SDVB\u5438\u7740\u5264<br>(ppb)<\/td><td>XAD-2\u30ec\u30b8\u30f3 A<br>(ppb)<\/td><td>XAD-2\u30ec\u30b8\u30f3 B<br>(ppb)<\/td><td>XAD-2\u30ec\u30b8\u30f3 C<br>(ppb)<\/td><\/tr><tr><td>PFBA<\/td><td>0.1539<\/td><td>2.409<\/td><td>3.288<\/td><td>4.661<\/td><td>1.324<\/td><\/tr><tr><td>PF4OPeA<\/td><td>ND<\/td><td>3.221<\/td><td>0.611<\/td><td>0.469<\/td><td>0.265<\/td><\/tr><tr><td>ADONA<\/td><td>ND<\/td><td>0.315<\/td><td>0.424<\/td><td>0.569<\/td><td>0.315<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>ND =&nbsp; \u691c\u51fa\u3055\u308c\u305a<br>\u30c6\u30b9\u30c8\u3092\u884c\u3063\u305fEPA OTM-45\u306e\u5bfe\u8c61\u3068\u306a\u308b\u5316\u5408\u7269\u3059\u3079\u3066\u306b\u3064\u3044\u3066\u3001Rezin\u5438\u7740\u5264\u304b\u3089\u306f\u691c\u51fa\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<p>\u307e\u305f\u3001\u4ed6\u793e\u88fd\u54c1\u306b\u306f\u7c92\u5b50\u6d41\u52d5\u6027\u304c\u306a\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30b9\u30e0\u30fc\u30ba\u306a\u53d6\u308a\u6271\u3044\u304c\u96e3\u3057\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin SDVB\u5438\u7740\u5264\u306f\u3001\u6b8b\u7559\u6eb6\u5a92\u3092\u9664\u53bb\u3057\u305f\u3046\u3048\u3067\u3001\u3075\u308b\u3044\u5206\u3051\u3068\u5747\u4e00\u5316\u3092\u884c\u3044\u3001\u30d1\u30c3\u30b1\u30fc\u30b8\u30f3\u30b0\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u7c92\u5b50\u306e\u584a\u304c\u3067\u304d\u305a\u3001\u6d41\u52d5\u6027\u304c\u512a\u308c\u305f\u3001\u30e9\u30dc\u306b\u3068\u3063\u3066\u4f7f\u3044\u3084\u3059\u304f\u6e05\u6d44\u5ea6\u304c\u9ad8\u3044\u30ec\u30b8\u30f3\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27242\">                                Catalog No. 27242                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Discontinued: \u5927\u6c17\u4e2dSVOC\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u7528\uff5c\u63ee\u767a\u6027PFAS\uff5cSDVB\u5438\u7740\u5264\uff5c\u6e05\u6d44\u5ea6\u4fdd\u8a3c\u4ed8\u304dRezin\uff5c100 g<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27242\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24230\">                                Catalog No. 24230                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u5927\u6c17\u4e2dSVOC\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u7528 XAD-2\u76f8\u5f53 | Clean SDVB\u30ec\u30b8\u30f3 | 100 g<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24230\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u7528\u306eRezin SDVB\u5438\u7740\u5264\u306f\u3001PAHs\u3084\u8fb2\u85ac\u3001PFAS\u306a\u3069\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u3092\u5fb9\u5e95\u7684\u306b\u6291\u3048\u3001EPA Method TO-13\u306b\u6e96\u62e0\u3057\u305f\u512a\u308c\u305f\u6e05\u6d44\u5ea6\u3092\u8a87\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001Ultra-Clean\u30ec\u30b8\u30f3SVDB\u5438\u7740\u5264\u306f\u3001\u30b3\u30b9\u30c8\u3092\u6291\u3048\u3064\u3064\u9ad8\u3044\u4fe1\u983c\u6027\u3067\u5927\u6c17\u5206\u6790\u306b\u5bfe\u5fdc\u3002<\/p>\n","protected":false},"author":11,"featured_media":6811,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2563,2551],"resource-technique":[],"ppma_author":[414],"class_list":["post-43533","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-resins-puf-accessories-ja","product-library-air-gas-sampling-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2563,"label":"\u30ec\u30b8\u30f3\uff5cPUF\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2551,"label":"\u5927\u6c17\uff5c\u30ac\u30b9 \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVSS4390-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":464,"filter":"raw","cat_ID":789,"category_count":464,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43533","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43533"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43533\/revisions"}],"predecessor-version":[{"id":68610,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43533\/revisions\/68610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6811"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43533"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43533"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43533"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43533"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43533"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43533"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43533"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43533"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43533"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}