{"id":43535,"date":"2025-10-03T21:19:37","date_gmt":"2025-10-03T21:19:37","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/improve-productivity-for-pesticides-analysis-with-resprep-fl-carboprep-plus-spe-japan\/"},"modified":"2025-11-25T23:14:50","modified_gmt":"2025-11-25T23:14:50","slug":"improve-productivity-for-pesticides-analysis-with-resprep-fl-carboprep-plus-spe-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evss4396-ja\/improve-productivity-for-pesticides-analysis-with-resprep-fl-carboprep-plus-spe-japan","title":{"rendered":"\u8fb2\u85ac\u5206\u6790\u306b\u6700\u9069\uff01Resprep FL\uff0bCarboPrep Plus\u3067\u751f\u7523\u6027\u5411\u4e0a\uff01"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Florisil\u3068\u30ab\u30fc\u30dc\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u7a4d\u5c64\u56fa\u76f8\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3067\u3001Florisil\u5358\u72ec\u3067\u306f\u9664\u53bb\u3057\u304d\u308c\u306a\u3044\u5171\u62bd\u51fa\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u3088\u308a\u52b9\u679c\u7684\u306b\u9664\u53bb<\/li>\n\n\n\n<li>\u62bd\u51fa\u6db2\u304c\u3088\u308a\u30af\u30ea\u30fc\u30f3\u306a\u305f\u3081\u3001GC\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u77ed\u7e2e\u3055\u308c\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c10\u500d\u4ee5\u4e0a\u5411\u4e0a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u8907\u96d1\u306a\u571f\u58cc\u3084\u6c34\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u3092\u5206\u6790\u3059\u308b\u969b\u306b\u3001\u5171\u62bd\u51fa\u3055\u308c\u305f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304cGC\u306e\u6ce8\u5165\u53e3\u3084\u30ab\u30e9\u30e0\u3092\u6c5a\u67d3\u3057\u3066\u3057\u307e\u3046\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u6642\u9593\u306e\u304b\u304b\u308b\u4e88\u5b9a\u5916\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u3068\u306a\u308a\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u767a\u751f\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u52b9\u679c\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306b\u3088\u308b\u62bd\u51fa\u6db2\u306e\u54c1\u8cea\u5411\u4e0a\u304c\u3001\u88c5\u7f6e\u306e\u5b89\u5b9a\u7684\u306a\u52d5\u4f5c\u3068\u3001\u6b63\u78ba\u304b\u3064\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u53d6\u5f97\u306b\u306f\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EPA Method 3620\u306a\u3069\u3001\u4e00\u822c\u7684\u306a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u65b9\u6cd5\u3068\u3057\u3066\u5e83\u304f\u4f7f\u308f\u308c\u3066\u3044\u308b\u306e\u306f\u3001Florisil\u5358\u72ec\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u7528\u3044\u305f\u30d1\u30b9\u30b9\u30eb\u30fcSPE\uff08\u56fa\u76f8\u62bd\u51fa\uff09\u3067\u3059\u3002\u4e00\u65b9\u3001Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08Resprep FL + CPP\uff09\u306f\u3001Florisil\u3068\u30ab\u30fc\u30dc\u30f3\u3092\u4e00\u3064\u306b\u7d44\u307f\u5408\u308f\u305b\u305f\u7a4d\u5c64\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3067\u3001\u306f\u308b\u304b\u306b\u52b9\u679c\u7684\u306a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u304c\u5b9f\u73fe\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001GC\u30ab\u30e9\u30e0\u306e\u8010\u7528\u671f\u9593\u304c\u5ef6\u3073\u3001\u88c5\u7f6e\u306e\u7a3c\u50cd\u7387\u304c\u5411\u4e0a\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u51e6\u7406\u80fd\u529b\u3068\u30e9\u30dc\u5168\u4f53\u306e\u751f\u7523\u6027\u304c\u98db\u8e8d\u7684\u306b\u9ad8\u307e\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u4f7f\u308f\u308c\u3066\u3044\u308bFlorisil\u306b\u306f\u3001\u7279\u5225\u306a\u6c34\u5206\u7ba1\u7406\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u5145\u586b\u5264\u3092\u5b8c\u5168\u306b\u6d3b\u6027\u5316\u3057\u3001\u9ad8\u6975\u6027\u306a\u6c5a\u67d3\u7269\u8cea\u3092\u52b9\u679c\u7684\u306b\u9664\u53bb\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u3002Florisil\u306f\u9ad8\u6975\u6027\u5316\u5408\u7269\u3092\u6355\u6349\u3059\u308b\u306b\u306f\u6700\u9069\u306a\u5145\u586b\u5264\u3067\u3059\u3002\u3057\u304b\u3057\u3001GC\u6ce8\u5165\u53e3\u3092\u6c5a\u67d3\u3057\u3001\u88c5\u7f6e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u539f\u56e0\u3068\u306a\u308b\u9ad8\u5206\u5b50\u91cf\u306e\u6c5a\u67d3\u7269\u8cea\u306e\u9664\u53bb\u306b\u306f\u9069\u3057\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u554f\u984c\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u306e\u304cCarboPrep Plus\u5145\u586b\u5264\u3067\u3059\u3002\u3053\u306e\u5145\u586b\u5264\u306f\u3001\u7279\u306b\u5384\u4ecb\u306a\u5171\u62bd\u51fa\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u52b9\u679c\u7684\u306b\u9664\u53bb\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30d5\u30df\u30f3\u9178\u304c\u62bd\u51fa\u6db2\u306b\u6b8b\u5b58\u3057\u3066\u3044\u308b\u5834\u5408\u3001DDT\u306a\u3069\u306e\u5206\u89e3\u3092\u5f15\u304d\u8d77\u3053\u3057\u3084\u3059\u304f\u306a\u308a\u3001\u6ce8\u5165\u53e3\u3067\u306e\u5206\u89e3\u7387\u304c15%\u672a\u6e80\u306b\u6291\u3048\u3089\u308c\u306a\u3044\u3001\u3042\u308b\u3044\u306f\u7d99\u7d9a\u7684\u306a\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u30c1\u30a7\u30c3\u30af\u304c\u57fa\u6e96\u3092\u6e80\u305f\u305b\u306a\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u4f7f\u308f\u308c\u3066\u3044\u308b\u9ad8\u54c1\u8cea\u30ab\u30fc\u30dc\u30f3\u306f\u3001\u3053\u3046\u3057\u305f\u9178\u6027\u6210\u5206\u3092\u52b9\u679c\u7684\u306b\u9664\u53bb\u3067\u304d\u308b\u305f\u3081\u3001Florisil\u5358\u72ec\u3067\u51e6\u7406\u3057\u305f\u5834\u5408\u3068\u6bd4\u8f03\u3057\u3066\u3001\u6027\u80fd\u8981\u4ef6\u3092\u3088\u308a\u9577\u671f\u9593\u7dad\u6301\u3057\u3001\u6ce8\u5165\u53ef\u80fd\u306a\u30b5\u30f3\u30d7\u30eb\u6570\u3082\u5927\u5e45\u306b\u5897\u52a0\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u898b\u305f\u76ee\u306b\u3082\u62bd\u51fa\u6db2\u304c\u30af\u30ea\u30fc\u30f3\u306b\u306a\u308b\u3068\u3044\u3046\u5229\u70b9\u3082\u3042\u308a\u307e\u3059\uff08<strong>Figure 1<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Resprep FL+ CarboPrep Plus SPE\u306b\u3088\u308b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306f\u3001Florisil\u306e\u307f\u3092\u4f7f\u3063\u305f\u5834\u5408\u3068\u6bd4\u3079\u306610\u500d\u4ee5\u4e0a\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"587\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure_article_EVSS4396_01-JPsuzu-1024x587.png\" alt=\"\" class=\"wp-image-18759\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_01-JPsuzu-1024x587.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_01-JPsuzu-300x172.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_01-JPsuzu-768x440.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_01-JPsuzu-1536x881.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_01-JPsuzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em>\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\uff1aDDT\uff08100ppb\uff09\u306e\u5206\u89e3\u7387\u3092\u3001\u30d5\u30ed\u30ea\u30b8\u30ebSPE\u307e\u305f\u306fResprep FL+CarboPrep Plus SPE\u3067\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3057\u305f\u571f\u58cc\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u6db2\u306b\u3064\u3044\u3066\u300110\u56de\u3054\u3068\u306b\u6e2c\u5b9a<\/em><\/p>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u3088\u308a\u30af\u30ea\u30fc\u30f3\u306a\u62bd\u51fa\u6db2\u3092\u6c42\u3081\u308b\u306a\u3089\u3001Resprep FL+ CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u4e00\u629e\uff01<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u3001\u5171\u62bd\u51fa\u30b5\u30f3\u30d7\u30eb\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6c5a\u67d3\u7269\u8cea\u3092\u9664\u53bb\u3059\u308b\u624b\u9806\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u305d\u306e\u624b\u9806\u306f\u3001\u5f93\u6765\u306eFlorisil\u306b\u3088\u308b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3067\u5b9f\u65bd\u3059\u308b\u624b\u9806\u3068\u540c\u3058\u3067\u3059\u3002\u305f\u3060\u3057\u3001<strong>Figure 2<\/strong>\u3067\u305d\u306e\u9055\u3044\u3092\u78ba\u8a8d\u3057\u3066\u4e0b\u3055\u3044\u3002\u30b5\u30f3\u30d7\u30eb\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u5e73\u8861\u5316\u3001\u62bd\u51fa\u6db2\u30ed\u30fc\u30c9\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306e\u6eb6\u51fa\uff08\u6eb6\u51fa\u6eb6\u5a92\u306f\u3001\u30d8\u30ad\u30b5\u30f3:\u30a2\u30bb\u30c8\u30f3\uff0890:10\uff09\u3092\u4f7f\u7528\uff09\u3068\u3044\u3046\u3001\u540c\u3058\u624b\u9806\u3001\u6eb6\u5a92\u3001\u6eb6\u5a92\u91cf\u306a\u306e\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u3001Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u5f97\u3089\u308c\u305f\u62bd\u51fa\u6db2\u306f\u3001\u3088\u308a\u30af\u30ea\u30fc\u30f3\u3067\u3059\u3002\u3053\u306e\u62bd\u51fa\u6db2\u306b\u3088\u3063\u3066\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7d50\u679c\u3082\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3059\u3002Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001Florisil\u306b\u3088\u308b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3068\u540c\u3058\u624b\u9806\u3068\u6761\u4ef6\u3067\u305d\u306e\u307e\u307e\u4f7f\u3048\u308b\u4ee3\u66ff\u54c1\u3067\u3042\u308b\u3053\u3068\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3067\u9ad8\u3044\u9664\u53bb\u52b9\u679c\u3092\u793a\u3059\u305f\u3081\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u3055\u3089\u306a\u308b\u7c21\u7d20\u5316\u306b\u3082\u8ca2\u732e\u3057\u307e\u3059\u3002\u6c5a\u67d3\u5ea6\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3060\u3051\u3067\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\uff01<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u6a19\u6e96\u7684\u306aFlorisil\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u624b\u9806\u3068\u540c\u3058\u624b\u9806\u3067\u3001\u3088\u308a\u30af\u30ea\u30fc\u30f3\u306a\u62bd\u51fa\u6db2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"967\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure_article_EVSS4396_02JPsuzu-1024x967.png\" alt=\"\" class=\"wp-image-18777\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_02JPsuzu-1024x967.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_02JPsuzu-300x283.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_02JPsuzu-768x725.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_02JPsuzu-1536x1451.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure_article_EVSS4396_02JPsuzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c7\u30fc\u30bf\u54c1\u8cea\u3068\u7d50\u679c\u7cbe\u5ea6\u306e\u5411\u4e0a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304c\u5b9f\u73fe\u3059\u308b\u306e\u306f\u3001\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u77ed\u7e2e\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5411\u4e0a\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u7c21\u7d20\u5316\u3060\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u5206\u6790\u7cbe\u5ea6\u306e\u5411\u4e0a\u306b\u3082\u5927\u304d\u304f\u8ca2\u732e\u3059\u308b\u305f\u3081\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u3001\u6b63\u78ba\u306a\u7d50\u679c\u306e\u5831\u544a\u304c\u53ef\u80fd\u3067\u3059\u3002\u5171\u62bd\u51fa\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u5f37\u529b\u304b\u3064\u52b9\u679c\u7684\u306b\u9664\u53bb\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u7531\u6765\u306e\u5e72\u6e09\u3092\u6291\u3048\u3001\u5b9a\u91cf\u7d50\u679c\u306e\u7cbe\u5ea6\u3092\u4f4e\u4e0b\u3055\u305b\u307e\u305b\u3093\u3002<strong>Table I<\/strong>\u306b\u793a\u3059\u901a\u308a\u3001\u30e9\u30dc\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u306e\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3067\u3001\u56de\u53ce\u7387\u306f80\uff5e110%\u306e\u8a31\u5bb9\u7bc4\u56f2\u306b\u53ce\u307e\u308a\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001Florisil\u306b\u3088\u308b\u30c8\u30ea\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\uff08TCP\uff09\u306e\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3082\u89b3\u5bdf\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u30a6\u30eb\u30c8\u30e9\u30af\u30ea\u30fc\u30f3\u306a\u5145\u586b\u5264\u3068\u53b3\u5bc6\u306b\u7ba1\u7406\u3055\u308c\u305f\u88fd\u9020\u30fb\u54c1\u8cea\u624b\u9806\u306b\u3088\u308a\u3001\u5e38\u306b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u4f4e\u3044\u72b6\u614b\u3001\u30ed\u30c3\u30c8\u9593\u306e\u4e00\u8cab\u3057\u305f\u6027\u80fd\u304c\u7dad\u6301\u3055\u308c\u3066\u3044\u307e\u3059\uff08<strong>Figure 3<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u3088\u308b\u9ad8\u52b9\u7387\u306a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3067\u6b63\u78ba\u304b\u3064\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\uff08n=8\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5316\u5408\u7269<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u6fc3\u5ea6 (ng\/mL)\u3000<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5e73\u5747\u56de\u53ce\u7387 (%)<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>%RSD<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">TCP<\/td><td class=\"has-text-align-left\" data-align=\"left\">100<\/td><td class=\"has-text-align-left\" data-align=\"left\">&lt; 1*<\/td><td class=\"has-text-align-left\" data-align=\"left\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">TCMX<\/td><td class=\"has-text-align-left\" data-align=\"left\">20<\/td><td class=\"has-text-align-left\" data-align=\"left\">98<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hexachlorobenzene<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">89<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">alpha-BHC<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">100<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">gamma-BHC<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">99<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">beta-BHC<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">102<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">delta-BHC<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">103<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Heptachlor<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">91<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Aldrin<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">98<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.8<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Heptachlor epoxide<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">103<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">gamma-Chlordane<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">105<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.4<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">alpha-Chlordane<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">96<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4,4&#8242;-DDE<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">99<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endosulfan I<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">101<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dieldrin<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">98<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endrin<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">97<\/td><td class=\"has-text-align-left\" data-align=\"left\">5.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4,4&#8242;-DDD<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">97<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endosulfan II<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">99<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4,4&#8242;-DDT<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">97<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endrin aldehyde<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">92<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.6<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methoxychlor<\/td><td class=\"has-text-align-left\" data-align=\"left\">50<\/td><td class=\"has-text-align-left\" data-align=\"left\">95<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endosulfan sulfate<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">100<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Endrin ketone<\/td><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">98<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">DCB<\/td><td class=\"has-text-align-left\" data-align=\"left\">20<\/td><td class=\"has-text-align-left\" data-align=\"left\">101<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc5%\u672a\u6e80\u3068\u3044\u3046\u8981\u4ef6\u3092\u30af\u30ea\u30a2<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Resprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u72ec\u81ea\u306e\u88fd\u9020\u65b9\u6cd5\u3068\u53b3\u5bc6\u306a\u54c1\u8cea\u7ba1\u7406\u306b\u3088\u308a\u3001\u5e38\u306b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u4f4e\u3044\u72b6\u614b\u3092\u5b9f\u73fe\u3057\u307e\u3059\uff08\u5404\u30ed\u30c3\u30c88\u56de\u6ce8\u5165\u306e\u30c7\u30fc\u30bf\u3092\u793a\u3057\u3066\u3044\u307e\u3059\uff09\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1523.png\" alt=\"Chromtographic Background of Resprep FL + CarboPrep Plus SPE Cartridges\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1523<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32027<\/li><li>32029<\/li><li>11141<\/li><li>23303<\/li><li>28899<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1523.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><em>Florisil\u306b\u3088\u308b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3092\u3055\u3089\u306b\u4e00\u6bb5\u30ec\u30d9\u30eb\u30a2\u30c3\u30d7\u3057\u305f\u3044\u65b9\u3078\u2500\u2500Resprep FL + CPP SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3078\u306e\u5207\u308a\u66ff\u3048\u3067\u3001\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u77ed\u7e2e\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u5411\u4e0a\u3001\u305d\u3057\u3066\u30e9\u30dc\u751f\u7523\u6027\u306e\u5168\u4f53\u7684\u306a\u5411\u4e0a\u3092\u5b9f\u73fe\u3057\u307e\u3057\u3087\u3046\uff01<\/em><\/h2>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28899\">                                \u30ab\u30bf\u30ed\u30b0No. 28899                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u56fa\u76f8\u62bd\u51fa GC\u524d\u51e6\u7406 \u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\uff5cResprep FL + CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8, 6 mL, \u30d5\u30ed\u30ea\u30b8\u30eb 1000 mg\/GCB 95 mg<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28899\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28995\">                                \u30ab\u30bf\u30ed\u30b0No. 28995                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep Florisil SPE Cartridge, 15 mL\/2000 mg, 15-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28995\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25845\">                                \u30ab\u30bf\u30ed\u30b0No. 25845                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u56fa\u76f8\u62bd\u51fa\u3000GC\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u9664\u53bb\u7528\uff5cResprep CarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8, 3 mL\/95 mg<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25845\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">                                \u30ab\u30bf\u30ed\u30b0No. 28298-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep QR-12 Vacuum Manifold<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">                                \u30ab\u30bf\u30ed\u30b0No. 28310-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Quick Replace Liners, PTFE, for Resprep QR Vacuum Manifolds, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Resprep FL\uff0bCarboPrep Plus SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001Florisil\u3068\u30ab\u30fc\u30dc\u30f3\u306e\u7a4d\u5c64\u69cb\u9020\u306b\u3088\u308a\u8fb2\u85ac\u5206\u6790\u306e\u62bd\u51fa\u6db2\u3092\u9ad8\u7cbe\u5ea6\u306b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3002GC\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u77ed\u7e2e\u3057\u3001\u30c7\u30fc\u30bf\u7cbe\u5ea6\u3068\u30e9\u30dc\u751f\u7523\u6027\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":6817,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2668,2289,2271,2287],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340,2346],"ppma_author":[414],"class_list":["post-43535","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-semivolatiles","industries-application-soil-sediment-biota-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-solid-phase-extraction-spe-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2668,"label":"Semivolatiles"},{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2346,"label":"\u56fa\u76f8\u62bd\u51fa (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVSS4396-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":789,"category_count":509,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43535"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43535\/revisions"}],"predecessor-version":[{"id":69224,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43535\/revisions\/69224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6817"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43535"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43535"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43535"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43535"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43535"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43535"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}