{"id":43597,"date":"2021-06-24T14:30:00","date_gmt":"2021-06-24T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-in-line-sample-preparation-method-development\/"},"modified":"2026-10-02T14:29:58","modified_gmt":"2026-10-02T14:29:58","slug":"japanese-in-line-sample-preparation-method-development","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar3550-ja\/japanese-in-line-sample-preparation-method-development","title":{"rendered":"\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406(ILSP)\u306f\u3001\u81ea\u52d5\u30b5\u30f3\u30d7\u30eb\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3092\u53ef\u80fd\u306b\u3057\u3001QuEChERS \u307e\u305f\u306fSPE\u306a\u3069\u306e\u6642\u9593\u304c\u304b\u304b\u308b\u624b\u52d5\u30d7\u30ed\u30bb\u30b9\u306b\u3068\u3063\u3066\u304b\u308f\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Restek Revive ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f2\u6b21\u5143LC\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u7528\u306b\u69cb\u6210\u3055\u308c\u305f\u30b7\u30b9\u30c6\u30e0\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\u3002ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u5171\u62bd\u51fa\u3055\u308c\u305f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u4fdd\u6301\u3057\u307e\u3059\u304c\u3001\u305d\u306e\u5f8c\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u6d17\u6d44\u6eb6\u5a92\u3067\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3059\u308b\u3053\u3068\u3067\u9664\u53bb\u3055\u308c\u307e\u3059\u3002\u5206\u6790\u4e2d\u306b\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3092\u304a\u3053\u306a\u3046\u305f\u3081\u3001ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u6b21\u306e\u6ce8\u5165\u307e\u3067\u306b\u65b0\u3057\u3044\u30b5\u30f3\u30d7\u30eb\u3092\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3059\u308b\u6e96\u5099\u304c\u6574\u3044\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5927\u304d\u304f\u5897\u5927\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u6975\u3081\u3066\u52b9\u7387\u306e\u826f\u3044\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u4f5c\u308a\u51fa\u3057\u307e\u3059\u3002Revive ILSP\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306f\u304d\u308f\u3081\u3066\u52b9\u679c\u7684\u3067\u3042\u308a\u3001\u6642\u9593\u3068\u8cbb\u7528\u3092\u7bc0\u7d04\u3059\u308b\u305f\u3081\u306b\u7c21\u5358\u306a\u56fa\u6db2\u62bd\u51fa\u3068\u7d44\u5408\u308f\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u3053\u3053\u3067\u306f\u3001\u3053\u306e\u52b9\u679c\u7684\u306a\u624b\u6cd5\u306e\u5229\u70b9\u3092\u3054\u7406\u89e3\u3044\u305f\u3060\u3051\u308b\u3088\u3046\u306b\u3001\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u304a\u3053\u306a\u3046\u969b\u306e\u7c21\u5358\u306a\u624b\u9806\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u8aac\u660e\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b7\u30b9\u30c6\u30e0\u306e\u69cb\u6210\u8981\u4ef6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ILSP\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u4f7f\u7528\u3059\u308b\u306b\u306f\u3001\u30d0\u30a4\u30ca\u30ea\u30dd\u30f3\u30d7\u307e\u305f\u306f\u30af\u30a9\u30fc\u30bf\u30ca\u30ea\u30dd\u30f3\u30d7\u3001\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u304c\u53ef\u80fd\u306a\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3001\u30ab\u30e9\u30e0\u30b3\u30f3\u30d1\u30fc\u30c8\u30e1\u30f3\u30c8\u3001\u304a\u3088\u3073\u691c\u51fa\u5668\u3092\u5099\u3048\u305fHPLC\u304c\u5fc5\u8981\u3067\u3059\u3002 \u56f31\u306b\u793a\u3059\u3088\u3046\u306b\u3001ILSP\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u30b7\u30b9\u30c6\u30e0\u306b\u306f\u6b21\u306e\u3082\u306e\u304c\u6c42\u3081\u3089\u308c\u307e\u3059:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6d17\u6d44\u6eb6\u5a92\u3092ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u9001\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u72ec\u7acb\u3057\u305f\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u30dd\u30f3\u30d7\u3002&nbsp;<\/li>\n\n\n\n<li>\u6d17\u6d44\u30b9\u30c6\u30c3\u30d7\u4e2d\u306bILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3078\u306e\u6eb6\u5a92\u306e\u6d41\u308c\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u305f\u3081\u306e6\u30dd\u30fc\u30c8\u3001\u9ad8\u5727\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u30d0\u30eb\u30d6\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u6a5f\u5668\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306b\u3064\u3044\u3066\u30b5\u30dd\u30fc\u30c8\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001\u6a5f\u5668\u30e1\u30fc\u30ab\u30fc\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 1:\u00a0<\/strong>ILSP\u5bfe\u5fdcHPLC\u306e\u30b7\u30b9\u30c6\u30e0\u69cb\u6210<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"626\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01-1024x626.jpg\" alt=\"\" class=\"wp-image-20085\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01-1024x626.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01-768x469.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01-1536x939.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30bd\u30c3\u30c9\u958b\u767a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u306e\u4ed6\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u624b\u6cd5\u3068\u540c\u69d8\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3084\u5206\u6790\u7a2e\u304c\u5909\u308f\u308b\u6bce\u306bILSP\u6761\u4ef6\u3092\u8a55\u4fa1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u4ee5\u4e0b\u306e\u300c\u5206\u6790\u7a2e\u30d1\u30b9\u30b9\u30eb\u30fc\u300d\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u4f7f\u7528\u3057\u3066\u3001\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u304a\u3053\u306a\u3044\u3001\u500b\u3005\u306e\u30a2\u30c3\u30bb\u30a4\u306b\u6700\u9069\u306aILSP\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u7a2e\u30d1\u30b9\u30b9\u30eb\u30fc\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u306f\u3001Revive ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u3001\u59a8\u5bb3\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u4fdd\u6301\u3057\u306a\u304c\u3089\u5206\u6790\u7a2e\u3092\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002\u5168\u3066\u306e\u5206\u6790\u7a2e\u304cILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u901a\u904e\u3057\u3066\u5206\u6790\u30ab\u30e9\u30e0\u3078\u5165\u308b\u3068\u30016\u30dd\u30fc\u30c8\u3001\u9ad8\u5727\u30d0\u30eb\u30d6\u306e\u30dd\u30b8\u30b7\u30e7\u30f3\u304c\u5207\u308a\u66ff\u308f\u308a\u307e\u3059\u3002\u305d\u3057\u3066ILSP\u306b\u4fdd\u6301\u3055\u308c\u3066\u3044\u305f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u306f\u3001\u72ec\u7acb\u3057\u305f\u30dd\u30f3\u30d7\u3092\u4f7f\u3063\u3066\u9001\u6db2\u3055\u308c\u308b\u6d17\u6d44\u6eb6\u5a92\u3067\u5ec3\u6db2\u30e9\u30a4\u30f3\u3078\u3068\u6392\u51fa\u3055\u308c\u307e\u3059\u3002\u6b21\u306e\u624b\u9806\u3067\u7279\u5b9a\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u9069\u5207\u306a\u30d0\u30eb\u30d6\u5207\u63db\u3048\u306e\u30bf\u30a4\u30df\u30f3\u30b0\u3068\u6d17\u6d44\u6eb6\u5a92\u6761\u4ef6\u3092\u6c7a\u3081\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6ce8\u8a18<\/em>:<em>&nbsp;\u4ee5\u4e0b\u3067\u306f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304a\u3088\u3073\u5206\u6790\u7a2e\u306e\u305f\u3081\u306e\u9069\u5207\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30e1\u30bd\u30c3\u30c9\u304c\u3059\u3067\u306b\u6c7a\u307e\u3063\u3066\u3044\u308b\u3053\u3068\u3092\u524d\u63d0\u3068\u3057\u3066\u3044\u307e\u3059\u3002\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u304c\u5b58\u5728\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u5206\u96e2\u3092\u78ba\u7acb\u3057\u3066\u304b\u3089\u9032\u3081\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u30b9\u30c6\u30c3\u30d7 1: \u30ab\u30e9\u30e0\u30ed\u30fc\u30c9 &#8211; ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u5206\u6790\u7a2e\u304c\u6eb6\u51fa\u3057\u304d\u308b\u6642\u9593\u306e\u78ba\u7acb<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u5168\u3066\u306e\u5206\u6790\u7a2e\u304cRevive ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u6eb6\u51fa\u3059\u308b\u306e\u306b\u304b\u304b\u308b\u6642\u9593\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306e\u3082\u306e\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u304cILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u5206\u6790\u30ab\u30e9\u30e0\u3078\u79fb\u52d5\u3059\u308b\u6642\u9593\u3001\u3064\u307e\u308a\u6700\u521d\u306e\u30d0\u30eb\u30d6\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u30a4\u30d9\u30f3\u30c8\u307e\u3067\u306e\u6642\u9593\u304c\u6c7a\u307e\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u56f32\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u5206\u6790\u30ab\u30e9\u30e0\u306e\u4ee3\u308f\u308a\u306b\u30e6\u30cb\u30aa\u30f3\u3092\u4f7f\u7528\u3057\u30666\u30dd\u30fc\u30c8\u5207\u308a\u66ff\u3048\u30d0\u30eb\u30d6\u3092\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5206\u96e2\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6761\u4ef6\u306e\u65e2\u5b58\u79fb\u52d5\u76f8\u3068\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u7528\u3044\u3066\u3001ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u5206\u6790\u7a2e\u306e\u6a19\u6e96\u6eb6\u6db2(\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306a\u3057)\u3092\u6ce8\u5165\u3057\u307e\u3059\u3002\u5fc5\u8981\u306b\u5fdc\u3058\u3066MRM\u30a6\u30a3\u30f3\u30c9\u30a6\u3092\u8abf\u6574\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u5f97\u3089\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u6700\u5f8c\u306b\u6eb6\u51fa\u3059\u308b\u5206\u6790\u7a2e\u3092\u898b\u3064\u3051\u307e\u3059\u3002\u3053\u306e\u5206\u6790\u7a2e\u304c\u5b8c\u5168\u306b\u6eb6\u51fa\u3057\u304d\u308b\u6642\u9593\u304c\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3078\u306e\u30ed\u30fc\u30c9\u30dd\u30b8\u30b7\u30e7\u30f3\u304b\u3089ILSP\u306e\u6d17\u6d44\u30dd\u30b8\u30b7\u30e7\u30f3(\u30b9\u30c6\u30c3\u30d72\u306e\u56f33\u53c2\u7167)\u3078\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u6700\u77ed\u306e\u6642\u9593\u306b\u306a\u308a\u307e\u3059\u3002\u30ed\u30c3\u30c8\u9593\u306b\u3088\u308b\u30ab\u30e9\u30e0\u4fdd\u6301\u306e\u308f\u305a\u304b\u306a\u5909\u52d5\u3092\u8003\u616e\u3057\u3001\u6700\u5f8c\u306b\u6eb6\u51fa\u3059\u308b\u5206\u6790\u7a2e\u304c\u5b8c\u5168\u306b\u6eb6\u51fa\u3057\u304d\u308b\u6642\u9593\u306b10\uff5e20\u79d2\u52a0\u3048\u307e\u3059\u3002&nbsp;<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 2:\u00a0<\/strong>\u30b9\u30c6\u30c3\u30d71\u306e\u30d0\u30eb\u30d6\u30dd\u30b8\u30b7\u30e7\u30f3\u3068\u30b7\u30b9\u30c6\u30e0\u69cb\u6210<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"466\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02-1024x466.jpg\" alt=\"\" class=\"wp-image-20097\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02-1024x466.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02-300x137.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02-768x350.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02-1536x700.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u30b9\u30c6\u30c3\u30d7 2: ILSP\u306e\u6d17\u6d44 \u2013 \u6d17\u6d44\u6eb6\u5a92\u7d44\u6210\u3068\u6761\u4ef6\u306e\u78ba\u7acb<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e2\u756a\u76ee\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u9069\u5207\u306a\u6d17\u6d44\u6eb6\u5a92\u7d44\u6210\u3068\u6700\u9069\u306a\u6d41\u91cf\u6761\u4ef6\u304a\u3088\u3073\u30d0\u30eb\u30d6\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u306e\u30bf\u30a4\u30df\u30f3\u30b0\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u308c\u306f1\u56de\u306e\u6ce8\u5165\u3067\u4fdd\u6301\u3055\u308c\u305f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u3001\u6b21\u306e\u6ce8\u5165\u306e\u524d\u306bRevive ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u78ba\u5b9f\u306b\u6d17\u3044\u6d41\u3055\u308c\u308b\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u306e\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6700\u521d\u306e\u6d17\u6d44\u6eb6\u5a92\u3068\u3057\u3066\u30012mM\u30ae\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u30680.1\uff05\u30ae\u9178\u3092\u542b\u3080\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u5a92\u3092\u4f5c\u6210\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u591a\u304f\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4ee5\u4e0b\u306b\u8aac\u660e\u3059\u308b\u3088\u3046\u306b\u3001\u6700\u521d\u306e\u7d50\u679c\u306b\u57fa\u3065\u3044\u3066\u4ed6\u306e\u6d17\u6d44\u6eb6\u5a92\u306e\u691c\u8a0e\u304c\u5fc5\u8981\u3068\u306a\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u7c21\u5358\u306b\u3059\u308b\u305f\u3081\u306b\u3001\u79fb\u52d5\u76f8B\u3092\u8abf\u88fd\u3057\u305f\u6d17\u6d44\u6eb6\u5a92\u306b\u7f6e\u304d\u63db\u3048\u307e\u3059(\u56f33)\u3002<\/li>\n\n\n\n<li>\u6d41\u91cf\u30921mL\/min\u306b\u3057\u3001ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30d6\u30e9\u30f3\u30af\u3092\u6ce8\u5165\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30d5\u30eb\u30b9\u30ad\u30e3\u30f3\u30e2\u30fc\u30c9\u3001\u307e\u305f\u306f\u7279\u5b9a\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30a4\u30aa\u30f3\u304c\u65e2\u77e5\u306e\u5834\u5408\u306f\u3001\u9078\u629e\u30a4\u30aa\u30f3\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0(SIM)\u30e2\u30fc\u30c9\u3067\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u30e2\u30cb\u30bf\u30fc\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30c8\u30fc\u30bf\u30eb\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0(TIC)\u304c\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306b\u623b\u308b\u306e\u306b\u5fc5\u8981\u306a\u6642\u9593\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u306f\u3001\u30e2\u30cb\u30bf\u30fc\u3057\u3066\u3044\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u5b8c\u5168\u306bILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u6d17\u3044\u6d41\u3055\u308c\u305f\u3053\u3068\u3092\u793a\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u3053\u308c\u306f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u30c8\u30e9\u30c3\u30d7\u3057\u305fILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u5b8c\u5168\u306b\u6d17\u3044\u6d41\u3059\u305f\u3081\u306b\u5fc5\u8981\u306a\u6642\u9593\u3067\u3042\u308a\u3001\u30c8\u30fc\u30bf\u30eb\u5206\u6790\u30b5\u30a4\u30af\u30eb\u30bf\u30a4\u30e0\u3068\u6bd4\u8f03\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\n<ul class=\"wp-block-list\">\n<li>\u5206\u6790\u6642\u9593\u306e\u7d42\u4e86\u524d\u306b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304cILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u5b8c\u5168\u306b\u6d17\u3044\u6d41\u3055\u308c\u3066\u3044\u308b\u5834\u5408(\u56f34)\u3001\u6d17\u6d44\u30e1\u30bd\u30c3\u30c9\u306e\u3055\u3089\u306a\u308b\u6700\u9069\u5316\u306f\u5fc5\u8981\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u5b9f\u969b\u306e\u5206\u6790\u4e2d\u306bILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u901a\u308b\u6d17\u6d44\u6eb6\u5a92(\u30dd\u30f3\u30d7C)\u306e\u6d41\u91cf\u3092\u5236\u5fa1\u3059\u308b2\u756a\u76ee\u306e\u72ec\u7acb\u3057\u305f\u30dd\u30f3\u30d7\u3092\u4f7f\u3063\u3066\u3001\u5168\u4f53\u7684\u306a\u30e1\u30bd\u30c3\u30c9\u306b\u30d7\u30ed\u30b0\u30e9\u30e0\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u304b\u3089\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u5b8c\u5168\u306b\u6d17\u3044\u6d41\u3059\u306e\u306b\u8981\u3059\u308b\u6642\u9593\u304c\u5fc5\u8981\u4ee5\u4e0a\u306b\u9577\u3044\u5834\u5408\u306f\u3001\u52b9\u7387\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u306b\u3001\u6d17\u6d44\u6eb6\u5a92\u306e\u7d44\u6210\u3084\u6d41\u91cf\u3092\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\n<ul class=\"wp-block-list\">\n<li>\u6700\u9ad8\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u5f97\u308b\u306b\u306f\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u6fc3\u5ea6\u30922\uff5e10mM\u3001\u9178\u6fc3\u5ea6\u30920.1\uff5e0.5\uff05\u306b\u4fdd\u3064\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002 ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u79fb\u52d5\u76f8\u3067\u521d\u671f\u6761\u4ef6\u306b\u623b\u3059\u969b\u306b\u306f\u3001\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u6c88\u6bbf\u3092\u9632\u3050\u3088\u3046\u306b\u6ce8\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6ce8\u8a18: \u6d17\u6d44\u6eb6\u5a92\u306f\u7de9\u885d\u4f5c\u7528\u304cpH2~8\u306e\u7bc4\u56f2\u5185\u306b\u306a\u308b\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/em><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 3:\u00a0<\/strong>\u30b9\u30c6\u30c3\u30d72\u306e\u30d0\u30eb\u30d6\u30dd\u30b8\u30b7\u30e7\u30f3\u3068\u30b7\u30b9\u30c6\u30e0\u69cb\u6210<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-03.jpg\" alt=\"decorative\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 4:\u00a0<\/strong>\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u304a\u3051\u308b\u30a4\u30d9\u30f3\u30c8\u306e\u30bf\u30a4\u30df\u30f3\u30b0\u4f8b<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3550-04.jpg\" alt=\"decorative\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u30b9\u30c6\u30c3\u30d7 3: \u30e1\u30bd\u30c3\u30c9\u306e\u66f4\u65b0 \u2013 \u65e2\u5b58\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3078ILSP\u30e1\u30bd\u30c3\u30c9\u30a4\u30d9\u30f3\u30c8\u3092\u8ffd\u52a0<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u6700\u7d42\u30b9\u30c6\u30c3\u30d7\u3067\u306f\u3001\u30b9\u30c6\u30c3\u30d71\u304a\u3088\u30732\u3067\u5f97\u3089\u308c\u305f\u60c5\u5831\u3092\u5229\u7528\u3057\u3066\u3001\u9069\u5207\u306a\u30bf\u30a4\u30e0\u30a4\u30d9\u30f3\u30c8\u3092\u65e2\u5b58\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306b\u7d44\u307f\u8fbc\u307f\u307e\u3059\u3002\u56f34\u306f\u3001\u65b0\u3057\u3044\u30a4\u30d9\u30f3\u30c8\u304c\u4e00\u822c\u7684\u306aHPLC\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30e1\u30bd\u30c3\u30c9\u306b\u633f\u5165\u3055\u308c\u308b\u4f4d\u7f6e\u306e\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002 \u98df\u54c1\u4e2d\u8fb2\u85ac\u306e\u65e2\u5b58\u5206\u6790\u6cd5\u306b\u304a\u3051\u308b\u3001\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30d7\u30ed\u30bb\u30b9\u306e\u4f8b\u3092\u8868I\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>\u8868 I:&nbsp;<\/strong>\u98df\u54c1\u4e2d\u8fb2\u85ac\u306b\u304a\u3051\u308bRevive\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30d7\u30ed\u30bb\u30b9\u306e\u4f8b<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td colspan=\"3\"><strong>\u5143\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30a4\u30d9\u30f3\u30c8\u30c6\u30fc\u30d6\u30eb:<\/strong><\/td><\/tr><tr><td><strong>Time (min)<\/strong><\/td><td><strong>%B Mobile Phase Composition<\/strong><\/td><td>&nbsp;<\/td><\/tr><tr><td>0<\/td><td>5<\/td><td>&nbsp;<\/td><\/tr><tr><td>2<\/td><td>60<\/td><td>&nbsp;<\/td><\/tr><tr><td>4<\/td><td>75<\/td><td>&nbsp;<\/td><\/tr><tr><td>6<\/td><td>100<\/td><td>&nbsp;<\/td><\/tr><tr><td>7<\/td><td>100<\/td><td>&nbsp;<\/td><\/tr><tr><td>7.01<\/td><td>5<\/td><td>&nbsp;<\/td><\/tr><tr><td>9<\/td><td>Stop<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"3\"><strong>ILSP\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3067\u6c7a\u5b9a\u3055\u308c\u305f\u5024:<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u30b9\u30c6\u30c3\u30d7 1:<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>ILSP\u304b\u3089\u6700\u5f8c\u306e\u5206\u6790\u7a2e\u304c\u6eb6\u51fa\u3059\u308b\u6642\u9593 = 4.6 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u6700\u5f8c\u306b\u6eb6\u51fa\u3057\u305f\u5316\u5408\u7269\u304c\u5b8c\u5168\u306b\u79fb\u52d5\u3059\u308b\u306e\u3092\u78ba\u5b9f\u306b\u3059\u308b\u305f\u3081\u306e\u8ffd\u52a0\u6642\u9593 = 0.3 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u30d0\u30eb\u30d6\u3092ILSP\u6d17\u6d44\u30dd\u30b8\u30b7\u30e7\u30f3\u306b\u5207\u308a\u66ff\u3048\u308b\u6642\u9593(\u4e0a\u8a18\u306e\u5408\u8a08) = 4.9 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u30b9\u30c6\u30c3\u30d7 2:<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u6d17\u6d44\u6eb6\u5a92\u7d44\u6210 = 2 mM \u30ae\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0 \u3068 0.1% \u30ae\u9178\u3092\u542b\u3080\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u5a92<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u6d17\u6d44\u6eb6\u5a92\u306e\u6d41\u91cf = 1 mL\/min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u30e2\u30cb\u30bf\u30fc\u53ef\u80fd\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304cILSP\u304b\u3089\u6eb6\u51fa\u3057\u304d\u308b\u6642\u9593 = 0.6 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u30c8\u30e9\u30c3\u30d7\u3055\u308c\u305f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u591a\u3044\u5834\u5408\u306e\u5909\u52d5\u3092\u8003\u616e\u3059\u308b\u305f\u3081\u306e\u8ffd\u52a0\u6642\u9593 = 0.4 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u5408\u8a08\u6d17\u6d44\u6642\u9593 = 1.0 min<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u6ce8\u8a18: \u6d17\u6d44\u6eb6\u5a92\u306e\u7d44\u6210\u3084\u6d41\u91cf\u306e\u5909\u66f4\u306f\u4e0d\u8981<\/strong><\/td><\/tr><tr><td colspan=\"3\"><strong>\u66f4\u65b0\u5f8c\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30a4\u30d9\u30f3\u30c8\u30c6\u30fc\u30d6\u30eb:<\/strong><\/td><\/tr><tr><td><strong>Time (min)<\/strong><\/td><td><strong>%B Mobile Phase Composition<\/strong><\/td><td><strong>Event<\/strong><\/td><\/tr><tr><td>0<\/td><td>5<\/td><td>&nbsp;<\/td><\/tr><tr><td>2<\/td><td>60<\/td><td>&nbsp;<\/td><\/tr><tr><td>4<\/td><td>75<\/td><td>&nbsp;<\/td><\/tr><tr><td>4.9<\/td><td>&#8211;<\/td><td>\u30d0\u30eb\u30d6\u3092\u5207\u308a\u66ff\u3048\u3066ILSP\u6d17\u6d44\u30dd\u30b8\u30b7\u30e7\u30f3\u3078(\u56f34\u53c2\u7167)<\/td><\/tr><tr><td>4.92<\/td><td>&#8211;<\/td><td>ILSP\u6d17\u6d44\u6eb6\u5a92\u6d41\u91cf\u30921 mL\/min\u3067\u9001\u6db2 (\u30dd\u30f3\u30d7C)<\/td><\/tr><tr><td>5.92<\/td><td>&#8211;<\/td><td>ILSP\u6d17\u6d44\u6eb6\u5a92\u306e\u30dd\u30f3\u30d7\u3092\u30aa\u30d5\u306b\u3057\u3066\u3001\u6eb6\u5a92\u3092\u7bc0\u7d04(\u30dd\u30f3\u30d7C)<\/td><\/tr><tr><td>6<\/td><td>100<\/td><td>&nbsp;<\/td><\/tr><tr><td>7<\/td><td>100<\/td><td>\u3053\u306e\u6642\u70b9\u3067\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306f\u5206\u6790\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa<\/td><\/tr><tr><td>7.01<\/td><td>5<\/td><td>\u30ab\u30e9\u30e0\u3092\u5e73\u8861\u5316\u3059\u308b\u305f\u3081\u306b\u3001\u521d\u671f\u79fb\u52d5\u76f8\u6761\u4ef6\u306b\u623b\u3059<\/td><\/tr><tr><td>7.05<\/td><td>&#8211;<\/td><td>ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u5e73\u8861\u5316\u3055\u305b\u308b\u305f\u3081\u3001\u30d0\u30eb\u30d6\u3092\u5207\u308a\u66ff\u3048\u3066<br>\u300c\u5206\u6790\u30ab\u30e9\u30e0\u3078\u306e\u30ed\u30fc\u30c9\u300d\u30dd\u30b8\u30b7\u30e7\u30f3\u3078*<\/td><\/tr><tr><td>9<\/td><td>Stop<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u30d0\u30eb\u30d6\u5207\u308a\u66ff\u3048\u306b\u3088\u3063\u3066\u5206\u6790\u4e2d\u306b\u751f\u3058\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3092\u56de\u907f\u3059\u308b\u305f\u3081\u3001\u30d0\u30eb\u30d6\u5207\u308a\u66ff\u3048\u306f\u3053\u306e\u6642\u70b9\u307e\u3067\u5f85\u3064\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3067\u751f\u3058\u308b\u307b\u3068\u3093\u3069\u306e\u554f\u984c\u306f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u30e1\u30bd\u30c3\u30c9\u306b\u95a2\u3059\u308b\u57fa\u672c\u7684\u306a\u77e5\u8b58\u304c\u3042\u308c\u3070\u56de\u907f\u307e\u305f\u306f\u4fee\u6b63\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u307e\u305a\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\u3068\u3057\u3066\u3001\u62bd\u51fa\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30d6\u30e9\u30f3\u30af\u3068\u62bd\u51fa\u6eb6\u5a92\u30d6\u30e9\u30f3\u30af\u306e\u30d7\u30ea\u30ab\u30fc\u30b5\u30fc\u30b9\u30ad\u30e3\u30f3\u30c7\u30fc\u30bf\u3092\u6bd4\u8f03\u3057\u3066\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u56fa\u6709\u306e\u30a4\u30aa\u30f3\u3092\u7279\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u30de\u30c8\u30ea\u30c3\u30af\u30b9\u56fa\u6709\u306e\u30a4\u30aa\u30f3\u304c\u6c7a\u5b9a\u3067\u304d\u308c\u3070\u3001\u305d\u308c\u3089\u3092\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306b\u8a2d\u5b9a\u3057\u3066SIM\u30e2\u30fc\u30c9\u3067\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3059\u308b\u3068\u3001\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u554f\u984c\u3092\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\u3059\u308b\u969b\u306b\u3001\u6b8b\u7559\u6027\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6c5a\u67d3\u7269\u8cea\u306e\u5b58\u5728\u304c\u554f\u984c\u306a\u306e\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3059\u308b\u306e\u306b\u4f7f\u7528\u3067\u304d\u308b\u8a3a\u65ad\u6750\u6599\u3068\u306a\u308a\u3048\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u30b7\u30ca\u30ea\u30aa\u306e\u89e3\u6c7a\u7b56\u3092\u8868II\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u3092\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u63a1\u7528\u3057\u3001\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u554f\u984c\u306b\u3069\u306e\u3088\u3046\u306b\u5bfe\u51e6\u3059\u308b\u304b\u3092\u8a8d\u8b58\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u306bILSP\u3092\u8ffd\u52a0\u3057\u3084\u3059\u304f\u306a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>\u8868 II:&nbsp;<\/strong>ILSP\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u75c7\u72b6<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u8003\u3048\u3089\u308c\u308b\u539f\u56e0<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5bfe\u51e6\u65b9\u6cd5<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6eb6\u51fa\u306e\u9045\u3044\u30d4\u30fc\u30af\u304c\u306a\u3044<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30ab\u30e9\u30e0\u30ed\u30fc\u30c9\u306e\u30a4\u30d9\u30f3\u30c8\u6642\u9593\u304c\u6b63\u3057\u304f\u306a\u3044<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30ab\u30e9\u30e0\u30ed\u30fc\u30c9\u306e\u6642\u9593\u3092\u9577\u304f\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u30d4\u30fc\u30af\u304c\u306a\u3044<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">MRM\u30a6\u30a3\u30f3\u30c9\u30a6\u306e\u8a2d\u5b9a\u304c\u6b63\u3057\u304f\u306a\u3044<\/td><td class=\"has-text-align-left\" data-align=\"left\">ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u8ffd\u52a0\u3059\u308b\u3068\u3001\u4fdd\u6301\u6642\u9593\u304c\u308f\u305a\u304b\u306b\u5909\u5316\u3057\u3001MRM\u30a6\u30a3\u30f3\u30c9\u30a6\u306e\u66f4\u65b0\u304c\u5fc5\u8981\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u6eb6\u51fa\u304c\u65e9\u3044\u5206\u6790\u7a2e\u306e\u30d4\u30fc\u30af\u304c\u30d6\u30ed\u30fc\u30c9\/\u6b6a\u3093\u3067\u3044\u308b<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30cb\u30fc\u30c9\u30eb\u6d17\u6d44\u6eb6\u5a92\u30df\u30b9\u30de\u30c3\u30c1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u306b\u5f37\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u30d0\u30f3\u30c9\u306e\u5e83\u304c\u308a\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u5fc5\u305a\u5f31\u6eb6\u5a92(\u521d\u671f\u79fb\u52d5\u76f8\u7d44\u6210)\u3067\u6d17\u6d44\u3057\u3066\u304f\u3060\u3055\u3044<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30eb\u6eb6\u5a92\u30df\u30b9\u30de\u30c3\u30c1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30d0\u30f3\u30c9\u306e\u5e83\u304c\u308a\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u4e3b\u306b\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u307e\u305f\u306f\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u5a92\u306b\u6eb6\u304b\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306f\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u30d4\u30fc\u30af\u306e\u6b6a\u307f\/\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u306f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5168\u3066\u306e\u5206\u6790\u7a2e\u304c\u5206\u6790\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3057\u3066\u304b\u3089\u3001\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u3092\u958b\u59cb\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u5206\u6790\u7a2e\u306e\u56de\u53ce\u7387\u304c\u4f4e\u3044<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3067\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u53ef\u6eb6\u5316\u3059\u308b\u6eb6\u5a92\u3067\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u3092\u6700\u9069\u5316\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6d17\u6d44\u4e0d\u8db3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u5b8c\u5168\u306b\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u3001\u6d17\u6d44\u6eb6\u5a92\u3092\u6700\u9069\u5316\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u6eb6\u5a92\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30d4\u30fc\u30af(\u30e2\u30cb\u30bf\u30fc\u6642)<\/strong><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3067\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u53ef\u6eb6\u5316\u3059\u308b\u6eb6\u5a92\u3067\u30cb\u30fc\u30c9\u30eb\u5185\u6d17\u6d44\u3092\u6700\u9069\u5316\u3057\u307e\u3059<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">ILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u6d17\u6d44\u4e0d\u8db3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e3b\u8981\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u5b8c\u5168\u306b\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u3001\u6d17\u6d44\u6eb6\u5a92\u3092\u6700\u9069\u5316\u3057\u307e\u3059<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u78ba\u7acb\u3057\u3001\u305d\u308c\u3092\u65e2\u5b58\u306eLC\u30e1\u30bd\u30c3\u30c9\u306b\u7d71\u5408\u3059\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7068,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789,7],"tags":[],"industries-application":[2275,2274],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2365,2343,2345],"ppma_author":[2814],"class_list":["post-43597","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","category-articles","industries-application-food-safety-ja","industries-application-food-beverage-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"},{"value":7,"label":"Articles"}],"industries-application":[{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSSS3549-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0},{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43597"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43597\/revisions"}],"predecessor-version":[{"id":104978,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43597\/revisions\/104978"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7068"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43597"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43597"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43597"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43597"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43597"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43597"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}