{"id":43632,"date":"2020-10-20T00:00:00","date_gmt":"2020-10-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-condition-a-new-capillary-gc-column-japan\/"},"modified":"2026-01-24T00:54:52","modified_gmt":"2026-01-24T00:54:52","slug":"how-to-condition-a-new-capillary-gc-column-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnan1533-ja\/how-to-condition-a-new-capillary-gc-column-japan","title":{"rendered":"\u65b0\u3057\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u3068\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u65b9\u6cd5"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u306b\u304a\u3051\u308b\u91cd\u8981\u306a\u8981\u7d20\u3067\u3042\u308a\u3001\u305d\u306e\u53d6\u4ed8\u3051\u3068\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u9069\u5207\u306b\u884c\u3046\u3053\u3068\u304c\u3001\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u3042\u308b\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306e\u9375\u3068\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u65b0\u3057\u304f\u8cfc\u5165\u3057\u305f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u3084\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u65b9\u6cd5\u306b\u95a2\u3057\u3066\u4e0d\u5b89\u304c\u3042\u308b\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306e\u9069\u5207\u306a\u53d6\u4ed8\u3051\u624b\u9806\u3068\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u65b9\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u8a73\u7d30\u306a\u60c5\u5831\u306f\u3001\u672c\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8\u306e\u8a18\u4e8b<a href=\"https:\/\/discover.restek.com\/instruction-sheet\/gnot5427\/restek-capillary-column-installation-guide\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/instruction-sheets-ja\/gnot5427\/restek-capillary-column-installation-guide\/\">Restek Capillary Column Installation Guide<\/a>\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 1:\u3000\u53d6\u4ed8\u3051\u524d\u306e\u6e96\u5099<\/strong><br>\u65b0\u3057\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092GC\u88c5\u7f6e\u306b\u53d6\u308a\u4ed8\u3051\u308b\u524d\u306b\u3001\u4ee5\u4e0b\u306e\u6e96\u5099\u3092\u884c\u3044\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>GC\u88c5\u7f6e\u5185\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374<br>\u6700\u521d\u306b\u3001GC\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374\u3057\u3001\u53e4\u3044\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u5916\u3057\u307e\u3059\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u308b\u969b\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u554f\u984c\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u53e4\u3044\u30ab\u30e9\u30e0\u306f\u307e\u3060\u6368\u3066\u305a\u306b\u4fdd\u7ba1\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002\u3082\u3057\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u554f\u984c\u304c\u767a\u751f\u3057\u305f\u5834\u5408\u3001\u53e4\u3044\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u53e4\u3044\u30ab\u30e9\u30e0\u306e\u51e6\u7406<br>\u53e4\u3044\u30ab\u30e9\u30e0\u306e\u4e21\u7aef\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30a8\u30f3\u30c9\u30ad\u30e3\u30c3\u30d7\u3084\u3001\u4f7f\u7528\u6e08\u307f\u306e\u6ce8\u5165\u53e3\u30bb\u30d7\u30bf\u30e0\u306e\u7834\u7247\u3067\u30b7\u30fc\u30eb\u3057\u3001\u30ab\u30e9\u30e0\u3092\u6a2a\u306b\u7f6e\u3044\u3066\u304a\u304d\u307e\u3059\u3002\u3053\u308c\u3067\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u6e96\u5099\u304c\u6574\u3044\u307e\u3057\u305f\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 2:\u3000\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051<\/strong><br>\u65b0\u3057\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u3092\u884c\u3044\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u624b\u9806\u3067\u614e\u91cd\u306b\u9032\u3081\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306e\u53d6\u51fa\u3057<br>\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u7bb1\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u4e0a\u90e8\u306b\u4ed8\u5c5e\u3057\u3066\u3044\u308b\u30a8\u30f3\u30c9\u30ad\u30e3\u30c3\u30d7\u307e\u305f\u306f\u30bb\u30d7\u30bf\u30e0\u3092\u5916\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u7aef\u306e\u30ab\u30c3\u30c8<br>\u30ab\u30e9\u30e0\u306e\u6ce8\u5165\u53e3\u5074\u306b\uff08\u30ab\u30e9\u30e0\u306e\u30bf\u30b0\u3092\u8aad\u3082\u3046\u3068\u3059\u308b\u3068\u30ab\u30e9\u30e0\u30b1\u30fc\u30b8\u306e\u524d\u5074\u306b\u3042\u308b\u7aef\u3001\u307e\u305f\u306f Integra-Guard \u30ea\u30c6\u30f3\u30b7\u30e7\u30f3\u30ae\u30e3\u30c3\u30d7\uff0f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u90e8\u304c\u3042\u308b\u5074\uff09\u3001\u30ab\u30e9\u30e0\u304c15\uff5e20cm\uff086\uff5e8 \u30a4\u30f3\u30c1\uff09\u51fa\u308b\u3088\u3046\u306b\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u30d5\u30a7\u30e9\u30eb\u3092\u901a\u3057\u3001\u30ab\u30e9\u30e0\u7aef\u3092\u7d0410cm\uff084\u30a4\u30f3\u30c1\uff09\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002\u30ab\u30c3\u30c8\u3059\u308b\u969b\u306b\u306f\u30bb\u30e9\u30df\u30c3\u30af\u88fd \u30b9\u30b3\u30a2\u30ea\u30f3\u30b0\u30a6\u30a7\u30cf\uff08\u307e\u305f\u306f\u540c\u69d8\u306e\u30c4\u30fc\u30eb\uff09\u306e\u6ed1\u3089\u304b\u306a\u9762\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30d5\u30a7\u30e9\u30eb\u306e\u53d6\u4ed8\u3051\u4e2d\u306b\u7834\u7247\u304c\u30ab\u30e9\u30e0\u5185\u306b\u5165\u308a\u8fbc\u307e\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u3067\u3059\u3002<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051<br>\u88c5\u7f6e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u306b\u5f93\u3044\u3001\u30ab\u30e9\u30e0\u3092\u6ce8\u5165\u53e3\u306b\u614e\u91cd\u306b\u633f\u5165\u3057\u3001\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u7de0\u3081\u307e\u3059\u3002\u3053\u306e\u969b\u3001\u9069\u5207\u306a\u6d41\u91cf\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9*\u3092\u30aa\u30f3\u306b\u3057\u3001\u8abf\u6574\u3057\u307e\u3059\uff08\u8a73\u7d30\u306f<strong>Table I<\/strong>\u53c2\u7167\uff09\u3002<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u5185\u306e\u30ac\u30b9\u6d41\u308c\u78ba\u8a8d<br>\u30ab\u30e9\u30e0\u306e\u51fa\u53e3\u5074\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u307e\u305f\u306f\u56fa\u5b9a\u76f8\u306b\u9069\u3057\u305f\u6eb6\u5a92\u306b\u6d78\u3057\u3001\u6c17\u6ce1\u306e\u6d41\u308c\u3067\u30ab\u30e9\u30e0\u5185\u306b\u30ac\u30b9\u304c\u6d41\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30d1\u30fc\u30b8\u306e\u5b9f\u65bd<br>\u30ab\u30e9\u30e0\u51fa\u53e3\u3092\u6eb6\u5a92\u304b\u3089\u53d6\u308a\u51fa\u3057\u300110\u301c40\u5206\u9593\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3067\u30d1\u30fc\u30b8\u3057\u307e\u3059\u3002\u30d8\u30ea\u30a6\u30e0\u307e\u305f\u306f\u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001<strong>Table I<\/strong>\u306e\u63a8\u5968\u6761\u4ef6\u306b\u5f93\u3063\u3066\u30d1\u30fc\u30b8\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">*\u6ce8\u610f: \u6c34\u7d20\u30ac\u30b9\u306f\u7206\u767a\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u306b\u6c34\u7d20\u304c\u5145\u6e80\u3057\u306a\u3044\u3088\u3046\u306b\u3057\u3001\u6c34\u7d20\u304c\u30aa\u30fc\u30d6\u30f3\u5185\u306b\u6d41\u5165\u3057\u3066\u3044\u308b\u9593\u306f\u30ab\u30e9\u30e0\u3092\u52a0\u71b1\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002\u6c34\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u5fc5\u8981\u306a\u3059\u3079\u3066\u306e\u5b89\u5168\u4e88\u9632\u63aa\u7f6e\u3092\u8b1b\u3058\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong>&nbsp; \u30d8\u30ea\u30a6\u30e0\u307e\u305f\u306f\u6c34\u7d20*\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u3092\u30d1\u30fc\u30b8\u3059\u308b\u969b\u306e\u6d41\u91cf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30ab\u30e9\u30e0\u5185\u5f84 (mm)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u6700\u5c0f\u6d41\u91cf(mL\/min)<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u6700\u5c0f\u30d1\u30fc\u30b8\u6642\u9593 (min)<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">0.45 \/ 0.53<br>0.32<br>0.25 \/ 0.28<br>0.15 \/ 0.18<br>0.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.0<br>1.5<br>1.0<br>0.8<br>0.5<\/td><td class=\"has-text-align-center\" data-align=\"center\">10<br>20<br>25<br>30 40<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Step 3: \u30d1\u30fc\u30b8\u624b\u9806\u3068\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af<\/strong><br>\u30d1\u30fc\u30b8\u3068\u306f\u3001\u30ab\u30e9\u30e0\u5185\u304b\u3089\u9178\u7d20\u3084\u6c34\u5206\u3092\u9664\u53bb\u3059\u308b\u4f5c\u696d\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u304c\u9ad8\u6e29\u3067\u4e0d\u53ef\u9006\u7684\u306a\u640d\u50b7\u3092\u53d7\u3051\u308b\u306e\u3092\u9632\u304e\u307e\u3059\u3002\u30d1\u30fc\u30b8\u4e2d\u306b\u306f\u96fb\u5b50\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u6f0f\u308c\u3092\u30c1\u30a7\u30c3\u30af\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u304c\u5b8c\u5168\u306b\u30ea\u30fc\u30af\u30d5\u30ea\u30fc\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306f<a href=\"https:\/\/www.restek.com\/c\/1107\" target=\"_blank\" rel=\"noreferrer noopener\">\u9ad8\u54c1\u8cea\u306a\u9178\u7d20\u30c8\u30e9\u30c3\u30d7<\/a>\u3092\u901a\u3057\u3066\u304b\u3089\u30ab\u30e9\u30e0\u306b\u901a\u3059\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002\u30d1\u30fc\u30b8\u5f8c\u3001\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u6e96\u5099\u306f\u5b8c\u4e86\u3067\u3059\u3002<strong>\u307e\u3060\u3001<\/strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u306b\u63a5\u7d9a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u3092\u9069\u5207\u306b\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u3001\u305d\u306e\u6027\u80fd\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3057\u3001\u9577\u671f\u7684\u306a\u5b89\u5b9a\u6027\u3092\u78ba\u4fdd\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u6642\u9593\u3068\u6e29\u5ea6\u306f\u3001\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306e\u5316\u5b66\u7684\u6027\u8cea\u3084\u539a\u3055\u3001\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u76ee\u7684\u3001\u4f7f\u7528\u3059\u308b\u691c\u51fa\u5668\u306e\u30bf\u30a4\u30d7\u306a\u3069\u306b\u3088\u308a\u7570\u306a\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306b\u4e00\u822c\u7684\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u624b\u9806\u3092\u793a\u3057\u307e\u3059\u3002<strong>Table II<\/strong>\u306e\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u6642\u9593\u306f\u6982\u7b97\u5024\u3067\u3059\u3002\u5b89\u5b9a\u3057\u305f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3068\u4e88\u60f3\u3055\u308c\u308b\u5316\u5408\u7269\u30d4\u30fc\u30af\u306b\u5bfe\u3057\u3066\u5341\u5206\u306aS\/N\u6bd4\u3092\u9054\u6210\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u6642\u9593\u3060\u3051\u3001\u30ab\u30e9\u30e0\u3092\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3059\u308b\u3068\u3044\u3046\u306e\u304c\u91cd\u8981\u3067\u3059\u3002\u3054\u4e0d\u660e\u306a\u70b9\u304c\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">Restek\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9<\/a>\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u6700\u9069\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u624b\u9806\u3092\u6c7a\u5b9a\u3059\u308b\u304a\u624b\u4f1d\u3044\u3092\u81f4\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf &nbsp; &nbsp;\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u624b\u9806<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u306e\u8a2d\u5b9a<br>GC\u30aa\u30fc\u30d6\u30f3\u306e\u6e29\u5ea6\u309240\u00b0C\u306b\u8a2d\u5b9a\u3057\u3001\u6607\u6e29\u901f\u5ea6\u309210\u00b0C\/\u5206\u306b\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u6700\u7d42\u6e29\u5ea6\u306e\u8a2d\u5b9a<br>\u5206\u6790\u3067\u8981\u6c42\u3055\u308c\u308b\u6700\u7d42\u6e29\u5ea6\u3088\u308a\u308220\u2103\u9ad8\u3044\u6e29\u5ea6\u3001\u307e\u305f\u306f\u30ab\u30e9\u30e0\u306e\u6700\u5927\u7b49\u6e29\u6e29\u5ea6\uff08\u3044\u305a\u308c\u304b\u4f4e\u3044\u65b9\uff09\u306b\u30aa\u30fc\u30d6\u30f3\u3092\u30d7\u30ed\u30b0\u30e9\u30e0\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u6ce8\u5165\u53e3\u306e\u52a0\u71b1<br>\u6ce8\u5165\u53e3\u3092\u9069\u5207\u306a\u6e29\u5ea6\u306b\u52a0\u71b1\u3057\u3001\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u306e\u4fdd\u6301<br>\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u304c\u8a2d\u5b9a\u6e29\u5ea6\u306b\u9054\u3057\u305f\u3089\u3001<strong>Table II<\/strong>\u306b\u8a18\u8f09\u3055\u308c\u305f\u6642\u9593\u3060\u3051\u305d\u306e\u6e29\u5ea6\u3092\u4fdd\u6301\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u51b7\u5374\u3068\u691c\u51fa\u5668\u63a5\u7d9a<br>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u6d41\u3057\u306a\u304c\u3089\u30aa\u30fc\u30d6\u30f3\u3092\u51b7\u5374\u3057\u3001\u4e0a\u8a18\u306e\u624b\u9806\u3067\u30ab\u30e9\u30e0\u306e\u691c\u51fa\u5668\u5074\u306b\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u30d5\u30a7\u30e9\u30eb\u3092\u901a\u3057\u3001\u305d\u306e\u5f8c\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u5074\u306b\u63a5\u7d9a\u3057\u3001\u624b\u98061\uff5e4\u3092\u7e70\u308a\u8fd4\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf &nbsp; &nbsp;\u30aa\u30fc\u30d0\u30fc\u30ca\u30a4\u30c8\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u6ce8\u610f\u70b9<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u5e38\u3001\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306f\u6570\u6642\u9593\u3067\u5b8c\u4e86\u3057\u307e\u3059\u304c\u3001\u7279\u5b9a\u306e\u5206\u6790\u306b\u306f\u30aa\u30fc\u30d0\u30fc\u30ca\u30a4\u30c8\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u304c\u5fc5\u8981\u306a\u5834\u5408\u3082\u3042\u308a\u3001\u7279\u306b\u6709\u52b9\u306a\u306e\u306f\u4ee5\u4e0b\u306e\u5834\u5408\u3067\u3059\u3002\u30ab\u30e9\u30e0\u3092\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u3067\u9577\u6642\u9593\u4f7f\u7528\u3059\u308b\u5834\u5408\uff08\u6a21\u64ec\u84b8\u7559\u5206\u6790\u306a\u3069\uff09\u3001\u539a\u819c\u3067\u9ad8\u30d6\u30ea\u30fc\u30c9\u306a\u30ab\u30e9\u30e0\u3092\u975e\u5e38\u306b\u9ad8\u611f\u5ea6\u306e\u691c\u51fa\u5668\uff08\u96fb\u5b50\u6355\u7372\u691c\u51fa\u5668\u3084\u8cea\u91cf\u5206\u6790\u8a08\u306a\u3069\uff09\u306b\u63a5\u7d9a\u3059\u308b\u5834\u5408\u3001\u307e\u305f\u306f\u5b89\u5b9a\u3057\u305f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3092\u5f97\u305f\u3044\u5834\u5408\u3001\u306a\u3069\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u904e\u5ea6\u306a\u52a0\u71b1\u306b\u3088\u308a\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u304c\u77ed\u304f\u306a\u308b\u3053\u3068\u3082\u3042\u308b\u306e\u3067\u30aa\u30fc\u30d0\u30fc\u30ca\u30a4\u30c8\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u614e\u91cd\u306b\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u8a73\u7d30\u306f\u88c5\u7f6e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3059\u308b\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u25cf &nbsp; &nbsp;\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3068\u30c7\u30e5\u30a2\u30eb\u30ab\u30e9\u30e0\u5206\u6790<\/strong><br>\u30ea\u30fc\u30af\u306f\u30ab\u30e9\u30e0\u63a5\u7d9a\u306b\u8d77\u56e0\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u305f\u3081\u3001\u63a5\u7d9a\u90e8\u306f\u5e38\u306b\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3044\u3001\u78ba\u5b9f\u306b\u30b7\u30b9\u30c6\u30e0\u3092\u5bc6\u5c01\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3082\u3057\u30c7\u30e5\u30a2\u30eb\u30ab\u30e9\u30e0\u5206\u6790\u3092\u884c\u3046\u5834\u5408\u306f\u3001\u305d\u308c\u305e\u308c\u306e\u30ab\u30e9\u30e0\u3092\u500b\u5225\u306b\u53d6\u308a\u4ed8\u3051\u3001\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3068\u30c6\u30b9\u30c8\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e21\u65b9\u306e\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u304c\u554f\u984c\u306a\u3044\u3053\u3068\u304c\u8a3c\u660e\u3055\u308c\u305f\u5f8c\u306b\u3001<a href=\"https:\/\/www.restek.com\/c\/1187\" target=\"_blank\" rel=\"noreferrer noopener\">MXT \u201cY\u201d-Union, \u201cY\u201d Press-Tight<\/a>\u307e\u305f\u306f\u540c\u69d8\u306e\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306b\u540c\u3058\u3088\u3046\u306b\u63a5\u7d9a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u3068\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306f\u3001\u7d50\u679c\u306e\u4fe1\u983c\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u975e\u5e38\u306b\u91cd\u8981\u306a\u5de5\u7a0b\u3067\u3059\u3002\u9069\u5207\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u624b\u9806\u3092\u78ba\u7acb\u3057\u305f\u3089\u3001\u305d\u306e\u60c5\u5831\u3092\u8a18\u9332\u3057\u3066\u304a\u304f\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u305d\u306e\u624b\u9806\u306b\u5f93\u3046\u3053\u3068\u3067\u3001\u5b89\u5b9a\u3057\u305f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3068\u512a\u308c\u305f\u30d4\u30fc\u30af\u5206\u96e2\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4e0a\u8a18\u306e\u4f5c\u696d\u4e2d\u306b\u3082\u3057\u4f55\u304b\u554f\u984c\u304c\u767a\u751f\u3057\u305f\u5834\u5408\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">Restek\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9<\/a>\u306b\u76f8\u8ac7\u3057\u3001\u5c02\u9580\u7684\u306a\u30b5\u30dd\u30fc\u30c8\u3092\u53d7\u3051\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp; \u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u6642\u9593<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"4\"><strong>\u4ee5\u4e0b\u306e\u30ab\u30e9\u30e0\u306e\u5834\u5408:<\/strong>&nbsp;MXT-1, MXT-1HT, MXT-1 SimDist, MXT-2887, MXT-500, MXT-Biodiesel TG<br>Rtx-1, Rtx-5, Rtx-5MS, Rtx-5Amine, Rtx-440, Rtx-1614, Rtx-2887, Rtx-G27, Rtx-Biodiesel, Rtx-DHA (PONA), Rtx-Mineral Oil, Rtx-PCB, Rtx-TNT, Rtx-TNT2<br>Rxi-1ms, Rxi-5ms, Rxi-5Sil MS, Rxi-XLB, Rxi-17, Rxi-17Sil MS, Rxi-35Sil MS<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u30ab\u30e9\u30e0\u9577<\/strong><br><strong>(meters)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\"><strong>\u819c\u539a<\/strong><br><strong>(\u00b5m)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>\u304a\u304a\u3088\u305d\u306e\u6642\u9593<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"> <strong>(min)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>(hr)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&lt;15<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">15<br>30<br>60<br>90<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.25<br>0.5<br>1&nbsp;&nbsp;<br>1.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">30<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">30<br>45<br>60<br>90<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5<br>0.75<br>1&nbsp;&nbsp;<br>1.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&gt;60<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">60<br>90<br>120&nbsp;&nbsp;<br>150&nbsp;&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">1&nbsp;&nbsp;<br>1.5<br>2&nbsp;&nbsp;<br>2.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"4\"><strong>\u4ee5\u4e0b\u306e\u30ab\u30e9\u30e0\u306e\u5834\u5408:<\/strong><br>MXT-20, MXT-35, MXT-50, MXT-65, MXT-65TG, MXT-200, MXT-502.2, MXT-624, MXT-1301, MXT-1701, MXT-Volatiles<br>Rtx-20, Rtx-35, Rtx-35 Amine, Rtx-50, Rtx-65, Rtx-65TG, Rtx-200, Rtx-200MS, Rtx-502.2, Rtx-624, Rtx-1301, Rtx-1701, Rtx-BAC Plus 1, Rtx-BAC Plus 2, Rtx-CLPesticides, Rtx-CLPesticides2, Rtx-Dioxin, Rtx-Dioxin2, Rtx-G43, Rtx-OPPesticides, Rtx-OPPesticides2, Rtx-VMS, Rtx-Volatiles, Rtx-VRX<br>Rxi-624Sil MS<br>Stx-CLPesticides, Stx-CLPesticides2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u30ab\u30e9\u30e0\u9577<\/strong><br><strong>(meters)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\"><strong>\u819c\u539a<\/strong><br><strong>(\u00b5m)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>\u304a\u304a\u3088\u305d\u306e\u6642\u9593<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"> <strong>(min)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>(hr)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&lt;15<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">20<br>40<br>60<br>80<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.3<br>0.7<br>1&nbsp;&nbsp;<br>1.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">30<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">40<br>60<br>80<br>100&nbsp;&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.7<br>1&nbsp;&nbsp;<br>1.3<br>1.7<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&gt;60<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">80<br>120&nbsp;&nbsp;<br>160&nbsp;&nbsp;<br>200&nbsp;&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.3<br>2&nbsp;&nbsp;<br>2.7<br>3.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"4\"><strong>\u4ee5\u4e0b\u306e\u30ab\u30e9\u30e0\u306e\u5834\u5408:<\/strong><br>DEX chiral phases<br>FAMEWAX<br>MXT-WAX<br>Rt-CW20M F&amp;F, Rt-2560, Rt-TCEP<br>Rtx-225, Rtx-2330, Rtx-WAX<br>Stabilwax, Stabilwax-DA, Stabilwax-DB<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><strong>\u30ab\u30e9\u30e0\u9577<\/strong><br><strong>(meters)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\"><strong>\u819c\u539a<\/strong><br><strong>(\u00b5m)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\"><strong>\u304a\u304a\u3088\u305d\u306e\u6642\u9593<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>(min)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>(hr)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&lt;15<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">30<br>45<br>60<br>90<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.5<br>0.75<br>1&nbsp;&nbsp;<br>1.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">30<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">60<br>90<br>120&nbsp;&nbsp;<br>150&nbsp;&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">1&nbsp;&nbsp;<br>1.5<br>2&nbsp;&nbsp;<br>2.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">&gt;60<\/td><td class=\"has-text-align-center\" data-align=\"center\">&nbsp;&nbsp;0.1 &#8211; 0.25<br>0.5 &#8211; 1.0<br>1.0 &#8211; 1.5<br>1.5 &#8211; 3.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">80<br>120&nbsp;&nbsp;<br>160&nbsp;&nbsp;<br>200&nbsp;&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.3<br>2&nbsp;&nbsp;<br>2.7<br>3.3<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20116\">                                \u30ab\u30bf\u30ed\u30b0No. 20116                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ceramic Scoring Wafer Tool, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20116\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u65b0\u3057\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306e\u53d6\u4ed8\u3051\u3068\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u65b9\u6cd5\u3092\u8a73\u7d30\u306b\u89e3\u8aac\u3002\u53d6\u4ed8\u3051\u624b\u9806\u3001\u30d1\u30fc\u30b8\u65b9\u6cd5\u3001\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3001\u30ab\u30e9\u30e0\u8a2d\u5b9a\u306a\u3069\u3001\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3092\u3001\u63a8\u5968\u4e8b\u9805\u3084\u6ce8\u610f\u70b9\u3082\u4ea4\u3048\u3066\u9806\u3092\u8ffd\u3063\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u3042\u308b\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u6271\u3044\u65b9\u6cd5\u3092\u5b66\u3073\u307e\u3057\u3087\u3046\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-43632","post","type-post","status-publish","format-standard","hentry","category-articles-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43632","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43632"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43632\/revisions"}],"predecessor-version":[{"id":84438,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43632\/revisions\/84438"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43632"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43632"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43632"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43632"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43632"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43632"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43632"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43632"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}