{"id":43637,"date":"2020-10-28T14:30:00","date_gmt":"2020-10-28T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/the-effects-of-lc-particle-choice-on-column-performance-2-7-vs-5-%c2%b5m-diameter-superficially-porous-particles-spp-japan\/"},"modified":"2026-01-28T22:14:04","modified_gmt":"2026-01-28T22:14:04","slug":"the-effects-of-lc-particle-choice-on-column-performance-2-7-vs-5-um-diameter-superficially-porous-particles-spp-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar2079-ja\/the-effects-of-lc-particle-choice-on-column-performance-2-7-vs-5-um-diameter-superficially-porous-particles-spp-japan","title":{"rendered":"LC\u30ab\u30e9\u30e0\u306e\u7c92\u5b50\u5f84\u9078\u629e\u304c\u30ab\u30e9\u30e0\u6027\u80fd\u306b\u53ca\u307c\u3059\u5f71\u97ff\uff1a2.7 \u00b5m vs 5 \u00b5m \u8868\u9762\u591a\u5b54\u6027\u5145\u5861\u5264\uff08SPP\uff09"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u8868\u9762\u591a\u5b54\u6027\u5145\u5861\u5264\uff08\u4e00\u822c\u7684\u306bSPP\u307e\u305f\u306f\u30b3\u30a2\u30b7\u30a7\u30eb\u7c92\u5b50\u3068\u547c\u3070\u308c\u308b\uff09\u306f\u3001\u9ad8\u901f\u304b\u3064\u52b9\u7387\u7684\u306aLC\u5206\u96e2\u3092\u63d0\u4f9b\u3067\u304d\u308b\u3053\u3068\u304c\u8a3c\u660e\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7c92\u5b50\u306f\u8584\u3044\u30b7\u30ea\u30ab\u306e\u591a\u5b54\u8cea\u5c64\u306b\u5305\u307e\u308c\u305f\u900f\u904e\u6027\u306e\u306a\u3044\u30b3\u30a2\u3092\u7279\u5fb4\u3068\u3057\u3066\u304a\u308a\u3001\u5168\u591a\u5b54\u6027\u5145\u586b\u5264\u3088\u308a\u3082\u306f\u308b\u304b\u306b\u9ad8\u3044\u52b9\u7387\u3068\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u306eRestek\u306eRaptor SPP LC\u30ab\u30e9\u30e0\u306f\u30011.8\u00b5m\u30012.7 \u00b5m\u30015 \u00b5m \u7c92\u5b50\u5f84\u3067\u5229\u7528\u53ef\u80fd\u3067\u3042\u308a\u3001\u5206\u6790\u8005\u306f\u7279\u5b9a\u306e\u6e2c\u5b9a\u306b\u6700\u9069\u306a\u30b5\u30a4\u30ba\u3092\u3001\u67d4\u8edf\u306b\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6700\u9069\u306aLC\u7c92\u5b50\u5f84\u306e\u9078\u629e\u306b\u5fc5\u305a\u3057\u3082\u660e\u78ba\u306a\u57fa\u6e96\u304c\u3042\u308b\u3068\u306f\u9650\u308a\u307e\u305b\u3093\u3002\u3053\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30ce\u30fc\u30c8\u3067\u306f\u30012.7 \u00b5m\u30685 \u00b5m\u7c92\u5b50\u5f84\u306b\u304a\u3051\u308bRaptor LC\u30ab\u30e9\u30e0\u306e\u52b9\u7387\u30fb\u611f\u5ea6\u3001\u304a\u3088\u3073\u5727\u529b\u306e\u9055\u3044\u3092\u691c\u8a0e\u3057\u3001\u76ee\u7684\u306e\u5b9f\u9a13\u6761\u4ef6\u3068\u5206\u6790\u88c5\u7f6e\u306e\u6027\u80fd\u306b\u57fa\u3065\u3044\u3066\u9069\u5207\u306a\u7c92\u5b50\u5f84\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306e\u30a2\u30c9\u30d0\u30a4\u30b9\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u52b9\u7387\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u52b9\u7387\u3068\u7dda\u901f\u5ea6\u307e\u305f\u306f\u6d41\u91cf\u306e\u95a2\u4fc2\u306f\u3001van Deemter\u30d7\u30ed\u30c3\u30c8\u304b\u3089\u8aac\u660e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u52b9\u7387\u306f\u7406\u8ad6\u6bb5\u9ad8\u3055\uff08H\uff09\u3067\u8868\u3055\u308c\u3001\u4e0e\u3048\u3089\u308c\u305f\u6d41\u91cf\u3067\u306e\u7406\u8ad6\u6bb5\u9ad8\u3055\u304c\u5c0f\u3055\u3044\u307b\u3069\u3001\u30ab\u30e9\u30e0\u306e\u52b9\u7387\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u30d4\u30fc\u30af\u304c\u3088\u308a\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308a\u3001\u5206\u96e2\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<strong>Figure 1<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001Raptor 2.7 \u00b5m\u30ab\u30e9\u30e0\u306f\u5168\u3066\u306e\u6d41\u91cf\u306b\u304a\u3044\u3066Raptor 5 \u00b5m \u30ab\u30e9\u30e0\u3088\u308a\u3082\u5e73\u5747\u3057\u306625\uff05\u4ee5\u4e0a\u9ad8\u3044\u52b9\u7387\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001Raptor 2.7 \u00b5m\u30ab\u30e9\u30e0\u3067\u306f\u3001\u3088\u308a\u9ad8\u3044\u6d41\u91cf\u3067\u52b9\u7387\u306e\u640d\u5931\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3057\u305f\u3002\u76f4\u5f844.6 mm\u306e\u30ab\u30e9\u30e0\u306e\u5834\u5408\u30012.7 \u00b5m\u7c92\u5b50\u5f84\u306e\u30ab\u30e9\u30e0\u306f1.0\uff5e1.6 mL\/min\u306e\u6d41\u91cf\u304c\u3082\u3063\u3068\u3082\u9ad8\u3044\u52b9\u7387\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002\u4e00\u65b9\u30675 \u00b5m\u7c92\u5b50\u5f84\u306e\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6d41\u91cf\u7bc4\u56f2\u304c 0.4 \uff5e 1.0 mL\/min \u306e\u5834\u5408\u306b\u3082\u3063\u3068\u3082\u9ad9\u3044\u52b9\u7387\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002 &nbsp; &nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Raptor 2.7 \u00b5m SPP\u30ab\u30e9\u30e0\u306f\u3001\u9ad8\u3044\u6d41\u91cf\u306b\u304a\u3044\u3066\u3082\u52b9\u7387\u3092\u7dad\u6301\u3057\u307e\u3059\u3002 \u00a0 \u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2079-01.jpg\" alt=\"chart, line chart\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\uff1a<\/strong>150 mm x 4.6 mm ID\uff1b<strong>\u00a0\u6e29\u5ea6\uff1a<\/strong>30 \u2103\uff1b\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<br><strong>\u79fb\u52d5\u76f8\uff1a<\/strong>\u6c34\uff1a\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff0845:55\uff09;\u00a0<strong>\u691c\u51fa<\/strong>\uff1a254 nm\uff1b\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<br><strong>\u30c6\u30b9\u30c8\u30d7\u30ed\u30fc\u30d6\uff1a<\/strong>\u30a6\u30e9\u30b7\u30eb\u3001\u30d3\u30d5\u30a7\u30cb\u30eb<\/p>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u611f\u5ea6\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u611f\u5ea6\u306f\u7279\u5b9a\u30d4\u30fc\u30af\u306e\u30b7\u30b0\u30ca\u30eb\u3068\u30ce\u30a4\u30ba\u306e\u6bd4\uff08S\/N\uff09\u304b\u3089\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u3002\u30ec\u30b9\u30dd\u30f3\u30b9\u306f\u30d4\u30fc\u30af\u5e45\u3092\u72ed\u304f\u3059\u308b\u3053\u3068\u3067\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u3092\u3088\u308a\u30b7\u30e3\u30fc\u30d7\u306b\u3059\u308b\u3053\u3068\u3067\u3001\u611f\u5ea6\u304c\u5411\u4e0a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u8868\u9762\u591a\u5b54\u6027\u5145\u5861\u5264\u306f\u975e\u591a\u5b54\u8cea\u306e\u900f\u904e\u6027\u304c\u306a\u3044\u30b3\u30a2\u3092\u3082\u3064\u305f\u3081\u5168\u591a\u5b54\u6027\u5145\u586b\u5264\u3068\u6bd4\u3079\u591a\u5b54\u8cea\u90e8\u5206\u304c\u5c11\u306a\u304f\u3001\u77ed\u3044\u62e1\u6563\u8ddd\u96e2\u3068\u306a\u308b\u305f\u3081\u3001\u7d50\u679c\u3068\u3057\u3066\u30d4\u30fc\u30af\u62e1\u6563\u304c\u6e1b\u5c11\u3057\u3001\u30d4\u30fc\u30af\u304c\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308a\u307e\u3059\u3002\u7c92\u5b50\u5f84\u306e\u9078\u629e\u304c S\/N \u306b\u53ca\u307c\u3059\u5f71\u97ff\u3092\u5b9f\u8a3c\u3059\u308b\u305f\u3081\u306b\u3001\u4e00\u822c\u7684\u306a\u533b\u85ac\u54c1\u3068\u305d\u306e\u4ee3\u8b1d\u7269\u3092\u30012.7 \u00b5m \u3068 5 \u00b5m \u7c92\u5b50\u3092\u5145\u586b\u3057\u305f Raptor Biphenyl \u30ab\u30e9\u30e0\u3067\u5206\u6790\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u5f97\u3089\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3001\u30d4\u30fc\u30af\u5e45\u3001\u304a\u3088\u3073S\/N\u3092<strong>Figure 2<\/strong>\u3067\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002Raptor 2.7 \u00b5m\u7c92\u5b50\u5f84\u30ab\u30e9\u30e0\u306fRaptor 5 \u00b5m\u7c92\u5b50\u5f84\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u5e73\u5747\u3057\u3066S\/N\u304c32\uff05\u5897\u52a0\u3057\u3001\u5e73\u5747\u30d4\u30fc\u30af\u5e45\u304c25\uff05\u6e1b\u5c11\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u8868\u9762\u591a\u5b54\u6027\u5145\u5861\u5264 2.7 \u00b5m\u30685 \u00b5m\u3092\u6bd4\u8f03\u3059\u308b\u3068\u30012.7 \u00b5m\u7c92\u5b50\u5f84\u306f\u5e73\u5747\u306732\uff05\u306eS\/N\uff08\uff1d\u3088\u308a\u9ad8\u3044\u611f\u5ea6\uff09\u3092\u63d0\u4f9b\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0597.png\" alt=\"Comparison of Naltrexone and 6-\u03b2-Naltrexol in Urine on Raptor Biphenyl 2.7 \u00b5m and 5 \u03bcm Columns by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0597<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A52<\/li><li>9309552<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>alcohol<\/li><li>alcohol addiction<\/li><li>alcohol dependence<\/li><li>alcohol treatment<\/li><li>opiod<\/li><li>opiod dependence<\/li><li>opiod treatment<\/li><li>treatment<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0597.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5727\u529b\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPP\u306e\u4e3b\u306a\u5229\u70b9\u306e1\u3064\u306f\u3001\u5168\u591a\u5b54\u6027\u5145\u586b\u5264\u3068\u6bd4\u8f03\u3057\u305f\u5834\u5408\u3001\u591a\u304f\u306e\u5834\u5408\u3067\u80cc\u5727\u304c\u540c\u7b49\u304b\u3001\u3055\u3089\u306b\u306f\u4f4e\u3044\u80cc\u5727\u3067\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u5411\u4e0a\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u7c92\u5b50\u5f84\u3092\u5c0f\u3055\u304f\u3059\u308b\u3053\u3068\u3067\u52b9\u7387\u304c\u5411\u4e0a\u3057\u3001\u5727\u529b\u306f\u7c92\u5b50\u30b5\u30a4\u30ba\u306e\u4e8c\u4e57\u306b\u53cd\u6bd4\u4f8b\u3057\u3066\u5897\u52a0\u3057\u307e\u3059\u3002<strong>Figure 3<\/strong>\u3067\u306f\u30015\u00b5m \u304b\u3089 2.7 \u00b5m \u306e\u7c92\u5b50\u306b\u5207\u308a\u66ff\u3048\u308b\u3068\u3001\u30ab\u30e9\u30e0\u80cc\u5727\u304c\u6d41\u91cf (0.4 \uff5e 2 mL\/min) \u3067\u5e73\u5747\u7d04 150% \u5897\u52a0\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u5727\u529b\u306b\u5f71\u97ff\u3059\u308b\u305d\u306e\u4ed6\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306b\u306f\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3001\u79fb\u52d5\u76f8\u7d44\u6210\u3001LC \u304a\u3088\u3073\u691c\u51fa\u30b7\u30b9\u30c6\u30e0\u306e\u6d41\u91cf\u5236\u9650\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> 5 \u00b5m\u304b\u30892.7 \u00b5m \u7c92\u5b50\u5f84\u306b\u5207\u308a\u66ff\u3048\u308b\u3068\u3001\u80cc\u5727\u304c\u7d04150\uff05\u5897\u52a0\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2079-03.jpg\" alt=\"chart, line chart\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\uff1a<\/strong>150 mm x 4.6 mm ID\uff1b<strong>\u6e29\u5ea6\uff1a<\/strong>30 \u2103\uff1b\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0<br><strong>\u79fb\u52d5\u76f8\uff1a<\/strong>\u6c34\uff1a\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff0845:55\uff09<\/p>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u672c\u691c\u8a3c\u306e\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor 2.7 \u00b5m\u30685 \u00b5m\u7c92\u5b50\u5f84\u306eSPP LC\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001\u88c5\u7f6e\u304a\u3088\u3073\u5206\u6790\u76ee\u7684\u3092\u8003\u616e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Raptor 5 \u00b5m\u30ab\u30e9\u30e0\uff1a<\/strong><br>Raptor 5 \u00b5m\u7c92\u5b50\u5f84\u30ab\u30e9\u30e0\u306f\u3001\u4f4e\u3044\u80cc\u5727\u3001\u512a\u308c\u305f\u52b9\u7387\u304a\u3088\u3073\u611f\u5ea6\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u3092\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u3067\u3001\u7279\u306b\u5727\u529b\u5236\u9650\u306e\u3042\u308b \u5f93\u6765\u306eLC \u30b7\u30b9\u30c6\u30e0\u306e\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Raptor 5 \u00b5m SPP \u306f\u3001\u5206\u6790\u5bfe\u8c61\u6570\u306e\u5c11\u306a\u3044\u9ad8\u901f\u30a2\u30c3\u30bb\u30a4\u306b\u6700\u9069\u306a\u7c92\u5b50\u5f84\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 \u5927\u304d\u3044\u30b7\u30b9\u30c6\u30e0\u30dc\u30ea\u30e5\u30fc\u30e0<br>\u2022 \u88c5\u7f6e\u8010\u5727400 bar<br>\u2022 \u5c11\u306a\u3044\u5206\u6790\u5bfe\u8c61\u6570\u3067\u3042\u308c\u3070\u30d4\u30fc\u30af\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u304c\u5c11\u306a\u304f\u3066\u3059\u307f\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Raptor 2.7 \u00b5m\u30ab\u30e9\u30e0\uff1a &nbsp; &nbsp;<\/strong><br>Raptor 2.7 \u00b5m\u7c92\u5b50\u5f84\u30ab\u30e9\u30e0\u306f\u3001\u3088\u308a\u9ad8\u3044\u5727\u529b\u3068\u5f15\u304d\u63db\u3048\u306b5 \u00b5m SPP\u3088\u308a\u3082\u9ad8\u3044\u52b9\u7387\u3068\u611f\u5ea6\u3092\u793a\u3057\u307e\u3059\u3002\u5c0f\u3055\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306e\u52b9\u7387\u306f\u30ab\u30e9\u30e0\u5916\u5bb9\u7a4d\u304c\u6700\u3082\u9855\u8457\u306b\u5f71\u97ff\u3059\u308b\u305f\u3081\u30012.7 \u00b5m\u30ab\u30e9\u30e0\u306f600 bar\u307e\u3067\u8010\u5727\u304c\u3042\u308b\u30b7\u30b9\u30c6\u30e0\u30dc\u30ea\u30e5\u30fc\u30e0\u304c\u5c0f\u3055\u3044\u30b7\u30b9\u30c6\u30e0\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002Raptor 2.7 \u00b5m SPP\u306f\u3001\u30d4\u30fc\u30af\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u3092\u5fc5\u8981\u3068\u3059\u308b\u591a\u6210\u5206\u5206\u6790\u306b\u6700\u9069\u306a\u9078\u629e\u80a2\u3068\u306a\u308a\u307e\u3059\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 \u6700\u5c0f\u306e\u30b7\u30b9\u30c6\u30e0\u30dc\u30ea\u30e5\u30fc\u30e0<br>\u2022 \u30b7\u30b9\u30c6\u30e0\u8010\u5727600 bar<br>\u2022 \u3088\u308a\u591a\u304f\u306e\u30d4\u30fc\u30af\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u3092\u5fc5\u8981\u3068\u3059\u308b\u591a\u6210\u5206\u5206\u6790<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306eRaptor LC\u30ab\u30e9\u30e0\u306f\u3001\u8868\u9762\u591a\u5b54\u6027\u5145\u5861\u5264\uff08\u4e00\u822c\u7684\u306bSPP\u307e\u305f\u306f\u300c\u30b3\u30a2\u30b7\u30a7\u30eb\u300d\u7c92\u5b50\u3068\u547c\u3070\u308c\u308b\uff09\u3092\u7279\u5fb4\u3068\u3057\u3066\u304a\u308a\u30011.8\u00b5m\u30012.7\u00b5m\u30015 \u00b5m\u306e\u7c92\u5b50\u5f84\u30b5\u30a4\u30ba\u304c\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30ce\u30fc\u30c8\u3067\u306f\u30012.7 \u00b5m\u30685 \u00b5m\u7c92\u5b50\u304c\u5145\u586b\u3055\u308c\u305fRaptor LC\u30ab\u30e9\u30e0\u306e\u52b9\u7387\u3001\u611f\u5ea6\u3001\u304a\u3088\u3073\u5727\u529b\u306e\u9055\u3044\u306b\u3064\u3044\u3066\u6bd4\u8f03\u691c\u8a0e\u3057\u307e\u3057\u305f\u3002\u9069\u5207\u306a\u7c92\u5b50\u5f84\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306e\u30d2\u30f3\u30c8\u3068\u3057\u3066\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":53,"featured_media":70645,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2365,2343,2345],"ppma_author":[606,760,608],"class_list":["post-43637","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR2079-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Sharon Lupo","author_link":"https:\/\/discover.restek.com\/ja\/author\/paul-connolly\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":507,"filter":"raw","cat_ID":789,"category_count":507,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":606,"user_id":0,"is_guest":1,"slug":"sharon-lupo","display_name":"Sharon Lupo","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lupo-sharon.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-lupo-sharon.png"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Sharon","last_name":"Lupo","user_url":"","job_title":"","description":""},{"term_id":760,"user_id":0,"is_guest":1,"slug":"ty-kahler","display_name":"Ty Kahler","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Ty","last_name":"Kahler","user_url":"","job_title":"","description":""},{"term_id":608,"user_id":53,"is_guest":0,"slug":"paul-connolly","display_name":"Paul Connolly","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-connolly-paul.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-connolly-paul.png"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Paul","last_name":"Connolly","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43637"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43637\/revisions"}],"predecessor-version":[{"id":85773,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43637\/revisions\/85773"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/70645"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43637"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43637"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43637"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43637"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43637"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43637"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43637"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43637"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}