{"id":43693,"date":"2021-01-11T00:00:00","date_gmt":"2021-01-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-lc-method-translation-will-switching-column-dimensions-speed-up-sample-analyses\/"},"modified":"2025-11-25T21:35:56","modified_gmt":"2025-11-25T21:35:56","slug":"japanese-lc-method-translation-will-switching-column-dimensions-speed-up-sample-analyses","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3316-ja\/japanese-lc-method-translation-will-switching-column-dimensions-speed-up-sample-analyses","title":{"rendered":"LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db: \u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3059\u308b\u3068\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u3092\u9ad8\u901f\u5316\u3067\u304d\u308b\u3067\u3057\u3087\u3046\u304b\uff1f"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306b\u3088\u308a\u5206\u6790\u6642\u9593\u3001\u6eb6\u5a92\u3001\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u3092\u7bc0\u7d04\u3059\u308b\u3053\u3068\u306f\u3001\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc(LC)\u30e1\u30bd\u30c3\u30c9\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306e\u304d\u308f\u3081\u3066\u4e00\u822c\u7684\u306a\u65b9\u6cd5\u3067\u3059\u3002LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3067\u306f\u3001\u540c\u3058\u7c92\u5b50\u30bf\u30a4\u30d7(Raptor\u306a\u3069)\u3068\u56fa\u5b9a\u76f8(\u30d3\u30d5\u30a7\u30cb\u30eb\u306a\u3069)\u3092\u7dad\u6301\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u7c92\u5b50\u5f84\u304c\u5c0f\u3055\u304f\u3001\u77ed\u304f\u3066\u5185\u5f84\u306e\u7d30\u3044\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u8a31\u5bb9\u53ef\u80fd\u306a\u7d50\u679c\u3092\u4fdd\u3061\u306a\u304c\u3089\u3082\u5206\u6790\u3092\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u5341\u5206\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u304c\u3082\u305f\u3089\u3055\u308c\u3001\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u6642\u9593\u3092\u5272\u304f\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u3055\u3089\u306b\u3088\u308a\u5c11\u91cf\u306e\u79fb\u52d5\u76f8\u3092\u7528\u3044\u308b\u8fc5\u901f\u306a\u30e1\u30bd\u30c3\u30c9\u304b\u3089\u3082\u305f\u3089\u3055\u308c\u308b\u5229\u70b9\u306e\u6069\u6075\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u7279\u306b\u91cd\u8981\u306a\u30da\u30a2\u306e\u5b8c\u5168\u306a\u5206\u96e2\u304c\u4e0d\u53ef\u6b20\u306a\u5834\u5408\u306b\u306f\u3001\u30ab\u30e9\u30e0\u3092\u5909\u66f4\u3059\u308b\u3060\u3051\u3067\u306f\u3046\u307e\u304f\u3044\u304d\u307e\u305b\u3093\u3002\u91cd\u8981\u306a\u5206\u96e2\u3092\u640d\u306a\u3046\u3053\u3068\u306e\u306a\u3044\u3088\u3046\u306b\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u5408\u305b\u3066\u5206\u6790\u6761\u4ef6\u3092\u5909\u66f4\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u5f79\u7acb\u3064\u306e\u304cLC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30b7\u30e7\u30f3\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u77ed\u6642\u9593\u3067\u307b\u307c\u540c\u3058\u5206\u96e2\u3092\u304a\u3053\u306a\u3046\u3068\u3044\u3046\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u306b\u306f\u3001\u30b5\u30a4\u30ba\u306f\u5c0f\u3055\u304f\u3068\u3082\u540c\u3058\u52b9\u7387\u3001\u3064\u307e\u308a\u307b\u307c\u540c\u7b49\u306e\u7406\u8ad6\u6bb5\u6570\u3092\u7dad\u6301\u3059\u308b\u30ab\u30e9\u30e0\u306b\u5909\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u3057\u304b\u3057\u3001\u5143\u306e\u30ab\u30e9\u30e0\u3068\u540c\u3058\u6bb5\u6570(\u00b110%)\u3092\u6709\u3059\u308b\u65b0\u305f\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u898b\u3064\u3051\u308b\u3053\u3068\u304c\u73fe\u5b9f\u7684\u3082\u3057\u304f\u306f\u53ef\u80fd\u3067\u3042\u308b\u3068\u306f\u9650\u308a\u307e\u305b\u3093\u3002 \u3053\u308c\u306f\u5909\u63db\u3092\u6210\u529f\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u3068\u3044\u3046\u610f\u5473\u3067\u306f\u306a\u304f\u3001\u73fe\u5728\u306e\u5206\u96e2\u306b\u4f55\u3089\u304b\u306e\u5909\u5316\u304c\u3042\u308b\u3068\u3044\u3046\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002 \u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u3088\u308a\u77ed\u6642\u9593\u3067\u5206\u6790\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u306e\u306b\u5f79\u7acb\u3064\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3066\u9078\u629e\u80a2\u3092\u691c\u8a0e\u3059\u308b\u4fa1\u5024\u306f\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306ePro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u3067\u3001\u8cea\u306e\u826f\u3044\u7d50\u679c\u3092\u5f97\u3064\u3064\u6642\u9593\u3092\u7bc0\u7d04\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3059\u308b\u305f\u3081\u306e\u65b9\u6cd5\u3092\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u30b7\u30ca\u30ea\u30aa<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u4f8b\u3067\u306f\u3001100mm\u00d73.0mm\u30012.7\u03bcm\u306eRaptor Biphenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u306b\u3059\u3067\u306b\u6210\u529f\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u307e\u305f\u300150mm x2.1mm\u30012.7\u03bcm\u306e\u30ab\u30e9\u30e0\u304c\u81ea\u793e\u306b\u3042\u308a\u3001\u5c0f\u3055\u306a\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u306b\u79fb\u884c\u3059\u308b\u3068\u3001\u5206\u6790\u6642\u9593\u304c\u77ed\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u77e5\u3063\u3066\u3044\u308b\u306e\u3067\u3001\u3088\u308a\u30b5\u30a4\u30ba\u306e\u5927\u304d\u306a\u30ab\u30e9\u30e0\u306b\u3088\u308b\u73fe\u884c\u306e\u30e1\u30bd\u30c3\u30c9\u304c\u3001\u3088\u308a\u77ed\u304f\u3001\u3088\u308a\u7d30\u3044\u30ab\u30e9\u30e0\u306b\u3046\u307e\u304f\u5909\u63db\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3092\u77e5\u308a\u305f\u3044\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7279\u5b9a\u306e\u30b1\u30fc\u30b9\u3067\u306f\u3001\u3088\u308a\u5c0f\u3055\u306a\u30ab\u30e9\u30e0\u306f\u3001\u7406\u8ad6\u6bb5\u6570\u5168\u4f53\u306b\u304a\u3051\u308b\u5927\u5e45\u306a\u640d\u5931\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u9069\u5207\u306a\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3067\u306f\u3001\u77ed\u6642\u9593\u3067\u540c\u3058\u5206\u96e2\u3092\u671f\u5f85\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u3057\u305f\u304c\u3063\u3066\u3001LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u7d50\u679c\u3068\u3057\u3066\u91cd\u8981\u306a\u5206\u96e2\u80fd\u304c\u5931\u308f\u308c\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 \u3057\u304b\u3057\u3001\u540c\u3058\u5206\u96e2\u304c\u5f97\u3089\u308c\u306a\u3044\u306b\u3057\u3066\u3082\u3001\u8a31\u5bb9\u53ef\u80fd\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u306f\u3067\u304d\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u8a08\u7b97\u3057\u3001\u65b0\u3057\u3044\u7d50\u679c\u3092\u4e88\u6e2c\u3059\u308b\u3053\u3068\u304c\u3001\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u3042\u308b\u3079\u304d\u59ff\u3068\u3057\u3066\u8a2d\u8a08\u3055\u308c\u305f\u3082\u306e\u3067\u3059\u3002\u305d\u308c\u3067\u306f\u3001\u305d\u308c\u304c\u3069\u306e\u3088\u3046\u306b\u6a5f\u80fd\u3059\u308b\u304b\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u4f8b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u5b9a\u306e\u4e71\u7528\u85ac\u7269\u5206\u6790\u3092\u4f8b\u306b\u3068\u308a\u307e\u3059\u3002\u5143\u306e\u9577\u3044\u30ab\u30e9\u30e0\u304c\u3082\u305f\u3089\u3059\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306b\u6e80\u8db3\u3057\u3066\u3044\u3066\u3082\u3001\u3088\u308a\u5c0f\u3055\u306a\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u306b\u5909\u63db\u3057\u3001\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u72a0\u7272\u306b\u3059\u308b\u3053\u3068\u306a\u304f\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u78ba\u8a8d\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u300215\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u306e\u3046\u3061\u3001MS\/MS\u3067\u533a\u5225\u3067\u304d\u306a\u3044\u305f\u3081\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u304c\u5fc5\u8981\u306a\u540c\u91cd\u4f53\u304c\uff15\u7d44\u3042\u308a\u307e\u3059\u3002\u30aa\u30ea\u30b8\u30ca\u30eb\u30e1\u30bd\u30c3\u30c9\u304c\u5206\u96e2\u3067\u304d\u308b\u305f\u3081\u3001\u5909\u63db\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u3082\u540c\u69d8\u306b\u6a5f\u80fd\u3059\u308b\u304b\u3069\u3046\u304b\u306b\u7279\u306b\u95a2\u5fc3\u304c\u304a\u304b\u308c\u307e\u3059\u3002 \u4e0b\u306e\u56f31\u306f\u3001100mm\u00d73.0mm\u3001\u7c92\u5b50\u5f842.7\u03bcm\u306e\u30ab\u30e9\u30e0\u306b\u3088\u308b\u30aa\u30ea\u30b8\u30ca\u30eb\u30e1\u30bd\u30c3\u30c9\u306e\u7d50\u679c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 1 :<\/strong>\u00a0\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3068\u30e1\u30bd\u30c3\u30c9\u3092\u7528\u3044\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0756.png\" alt=\"Original Conditions for Method Translator Article: Drugs of Abuse on Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0756<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine<\/a><\/td><td class=\"oth\">1.11<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone<\/a><\/td><td class=\"oth\">1.43<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">184.9<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/467-15-2\/Norcodeine\" target=\"_blank\" rel=\"noopener\">Norcodeine<\/a><\/td><td class=\"oth\">1.86<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">151.9<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norhydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5083-62-5\/Norhydrocodone\" target=\"_blank\" rel=\"noopener\">Norhydrocodone<\/a><\/td><td class=\"oth\">2.49<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">199.0<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6\u03b2-Naltrexol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/49625-89-0\/6\u03b2-Naltrexol\" target=\"_blank\" rel=\"noopener\">6\u03b2-Naltrexol<\/a><\/td><td class=\"oth\">3.32<\/td><td class=\"oth\">344.3<\/td><td class=\"oth\">326.1<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27203-92-5\/Tramadol\" target=\"_blank\" rel=\"noopener\">Tramadol<\/a><\/td><td class=\"oth\">4.42<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">58.0<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Normeperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-17-8\/Normeperidine\" target=\"_blank\" rel=\"noopener\">Normeperidine<\/a><\/td><td class=\"oth\">4.82<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">160.2<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-52-8\/Mirtazapine\" target=\"_blank\" rel=\"noopener\">Mirtazapine<\/a><\/td><td class=\"oth\">5.50<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">195.1<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clozapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5786-21-0\/Clozapine\" target=\"_blank\" rel=\"noopener\">Clozapine<\/a><\/td><td class=\"oth\">5.87<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">271.1<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentazocine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/359-83-1\/Pentazocine\" target=\"_blank\" rel=\"noopener\">Pentazocine<\/a><\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">218.1<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34084-50-9\/7-Aminoflunitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoflunitrazepam<\/a><\/td><td class=\"oth\">6.50<\/td><td class=\"oth\">284.1<\/td><td class=\"oth\">135.0<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54910-89-3\/Fluoxetine\" target=\"_blank\" rel=\"noopener\">Fluoxetine<\/a><\/td><td class=\"oth\">7.53<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">148.0<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1977-10-2\/Loxapine\" target=\"_blank\" rel=\"noopener\">Loxapine<\/a><\/td><td class=\"oth\">7.86<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">271.1<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EMDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102177-18-4\/EMDP\" target=\"_blank\" rel=\"noopener\">EMDP<\/a><\/td><td class=\"oth\">8.28<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">235.2<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thioridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-52-2\/Thioridazine\" target=\"_blank\" rel=\"noopener\">Thioridazine<\/a><\/td><td class=\"oth\">8.87<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">126.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A1E\" rel=\"noopener\">cat.# 9309A1E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3.0 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>0.5-10 \u00b5g\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid  <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>1.0<\/td><td>85<\/td><td>15<\/td><\/tr><tr><td>6.50<\/td><td>1.0<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>10.00<\/td><td>1.0<\/td><td>0<\/td><td>100<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A standard mix with 15 drugs of abuse was prepared in concentrations ranging from 500-10,000 ng\/mL in water. The solution was vortexed at 3000 rpm for 10 seconds to mix, and the supernatant was injected for LC-MS\/MS analysis.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A1E<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0756.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306b\u73fe\u5728\u306e\u30ab\u30e9\u30e0\u3068\u30e1\u30bd\u30c3\u30c9\u306b\u95a2\u3059\u308b\u60c5\u5831\u3092\u5165\u529b\u3057\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u6700\u9069\u306a\u30e1\u30bd\u30c3\u30c9\u3092\u63d0\u4f9b\u3067\u304d\u308b\u3088\u3046\u306b\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001FPP\u304b\u3089FPP(\u5168\u591a\u5b54\u6027\u7c92\u5b50)\u307e\u305f\u306fSPP\u304b\u3089SPP(\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50)\u306a\u3069\u3001\u540c\u3058\u7c92\u5b50\u30bf\u30a4\u30d7\u306e\u30ab\u30e9\u30e0\u9593\u3067\u5909\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u56f32\u306f\u3001\u5143\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3001\u6ce8\u5165\u91cf\u3001\u30c7\u30e5\u30a8\u30eb\u30dc\u30ea\u30e5\u30fc\u30e0\u3001\u300c\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u300d\u5024\u3001\u304a\u3088\u3073\u79fb\u52d5\u76f8\u6761\u4ef6(\u3053\u306e\u30b1\u30fc\u30b9\u3067\u306f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u5206\u6790)\u304c\u5165\u529b\u3055\u308c\u305f\u72b6\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30c7\u30d5\u30a9\u30eb\u30c8\u306e\u30c7\u30e5\u30a8\u30eb\u30dc\u30ea\u30e5\u30fc\u30e0\u3068\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u306e\u5024\u306b\u7279\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3054\u4f7f\u7528\u306e\u6a5f\u5668\u306e\u5024\u3067\u306f\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u5909\u63db\u3055\u308c\u305f\u5b9f\u884c\u6761\u4ef6\u4e0b\u306b\u304a\u3051\u308b\u91cd\u8981\u306a\u30da\u30a2\u306e\u5206\u96e2\u5ea6\u3084\u5316\u5408\u7269\u4fdd\u6301\u6642\u9593\u306a\u3069\u306e\u5024\u3092\u6c7a\u5b9a\u3059\u308b\u969b\u306b\u3001\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3053\u308c\u3089\u306e\u5024\u3092\u8003\u616e\u306b\u5165\u308c\u308b\u305f\u3081\u7279\u306b\u91cd\u8981\u3067\u3059\u3002 \u7279\u5b9a\u306e\u6a5f\u5668\u306b\u3064\u3044\u3066\u3053\u308c\u3089\u306e\u5024\u304c\u308f\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u6a5f\u5668\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3067\u3053\u308c\u3089\u306e\u60c5\u5831\u3092\u8abf\u3079\u308b\u304b\u3001\u6a5f\u5668\u306e\u88fd\u9020\u5143\u306b\u554f\u3044\u5408\u308f\u305b\u308b\u304b\u3001\u307e\u305f\u306f\u3053\u308c\u3089\u306e\u5024\u3092\u7d4c\u9a13\u7684\u306b\u6c7a\u5b9a\u3059\u308b\u65b9\u6cd5\u3092\u304a\u8abf\u3079\u304f\u3060\u3055\u3044\u3002 \u3053\u308c\u3089\u306e\u5024\u306e\u8a73\u7d30\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u7528\u8a9e\u96c6\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u53f3\u4e0a\u9685\u306b\u3042\u308b\u300c?\u300d\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 2:<\/strong>\u00a0LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3092\u7528\u3044\u305f\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\uff1a\u73fe\u5728\u306e\u30ab\u30e9\u30e0\u3001\u6a5f\u5668\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u60c5\u5831\u3092\u5165\u529b\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-02.jpg\" alt=\"graphical user interface, table\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u6307\u5b9a\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306b\u305d\u306e\u4ed5\u4e8b\u3092\u3055\u305b\u308b\u3053\u3068\u3067\u3059\u3002\u56f33\u306f\u3001\u3053\u306e\u4f8b\u3067\u691c\u8a0e\u3057\u305f\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u5165\u529b\u3057\u305f\u72b6\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002 \u65b0\u3057\u3044\u30ab\u30e9\u30e0\u60c5\u5831\u304c\u5165\u529b\u3055\u308c\u308b\u3068\u3001\u3053\u306e\u4f8b\u306e\u3088\u3046\u306b\u8b66\u544a\u30e1\u30c3\u30bb\u30fc\u30b8\u304c\u8868\u793a\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002 \u3053\u306e\u8b66\u544a\u306f\u3001\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u4e0b\u3067\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u9078\u629e\u6027\u306e\u5909\u5316\u306e\u53ef\u80fd\u6027\u3092\u8b66\u544a\u3059\u308b\u305f\u3081\u306e\u3082\u306e\u3067\u3059(\u3053\u306e\u4f8b\u3067\u306f\u3001\u5f8c\u307b\u3069\u3053\u306e\u8b66\u544a\u304c\u9069\u7528\u3055\u308c\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3057\u307e\u3059)\u3002\u540c\u69d8\u306e\u9078\u629e\u6027\u3092\u5b9f\u73fe\u3059\u308b\u306b\u306f\u3001\u5909\u63db\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u3092\u5143\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u5316\u5408\u7269\u304c\u6eb6\u51fa\u3059\u308b\u79fb\u52d5\u76f8\u6761\u4ef6\u306b\u4e00\u81f4\u3055\u305b\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002 \u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u5143\u306e\u30e1\u30bd\u30c3\u30c9\u3068\u540c\u3058\u79fb\u52d5\u76f8\u7d44\u6210\u3067\u5316\u5408\u7269\u3092\u6eb6\u51fa\u3055\u305b\u308b\u65b0\u3057\u3044\u79fb\u52d5\u76f8\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u4f5c\u6210\u3057\u3088\u3046\u3068\u3057\u307e\u3059\u304c\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3067\u306f\u305d\u308c\u304c\u3067\u304d\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u5909\u63db\u3055\u308c\u305f\u30ab\u30e9\u30e0\u306e\u5bb9\u91cf\u304c\u5143\u306e\u30ab\u30e9\u30e0\u3068\u5927\u5e45\u306b\u7570\u306a\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u5185\u3067\u5143\u306e\u79fb\u52d5\u76f8\u7d44\u6210\u304c\u9054\u6210\u3055\u308c\u308b\u524d\u307e\u305f\u306f\u5f8c\u306b\u5316\u5408\u7269\u304c\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u3001\u7279\u306b\u521d\u671f\u306e\u6eb6\u51fa\u5316\u5408\u7269\u306f\u3001\u7570\u306a\u308bB\uff05\u6761\u4ef6\u4e0b\u3067\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u9078\u629e\u6027\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3059\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u3053\u308c\u306b\u3064\u3044\u3066\u306e\u8a73\u7d30\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u7528\u8a9e\u96c6\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u3053\u306e\u5f71\u97ff\u3092\u53ef\u8996\u5316\u3059\u308b\u305f\u3081\u306e\u7279\u5225\u306a\u30c1\u30e3\u30fc\u30c8\u3092\u542b\u3080\u3001\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u7248\u306ePro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 3 :<\/strong>\u00a0\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306e\u30b5\u30a4\u30ba\u3092\u5165\u529b\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"753\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-753x1024.jpg\" alt=\"\" class=\"wp-image-21243\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-753x1024.jpg 753w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-221x300.jpg 221w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-768x1044.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-1129x1536.jpg 1129w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03-1506x2048.jpg 1506w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-03.jpg 1800w\" sizes=\"auto, (max-width: 753px) 100vw, 753px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u30dc\u30ea\u30e5\u30fc\u30e0\u52b9\u679c\u306e\u6d3b\u7528<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f34\u306f\u3001Pro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u304c\u8a08\u7b97\u3057\u305f\u3001\u65b0\u3057\u304f\u8abf\u6574\u3055\u308c\u305f\u6ce8\u5165\u91cf\u3068\u30e1\u30bd\u30c3\u30c9\u306e\u72b6\u614b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002 \u540c\u3058\u6a5f\u5668\u3067\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u884c\u3059\u308b\u5834\u5408\u3001\u307b\u304b\u306e\u5909\u66f4\u3092\u52a0\u3048\u305a\u306b\u30c7\u30e5\u30a8\u30eb\u30dc\u30ea\u30e5\u30fc\u30e0\u3068\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u306e\u5024\u3092\u540c\u3058\u306b\u4fdd\u3061\u307e\u3059\u3002 \u305f\u3060\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u5225\u306e\u6a5f\u5668\u306b\u79fb\u3057\u305f\u308a\u3001\u4ed6\u306e\u5909\u66f4\u3092\u884c\u3046\u5834\u5408\u306f\u3001\u65b0\u3057\u3044\u5024\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 4:<\/strong>\u00a0\u5143\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u6eb6\u51fa\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3068\u4e00\u81f4\u3059\u308b\u3088\u3046\u306b\u3001\u5909\u63db\u3055\u308c\u305f\u6ce8\u5165\u91cf\u306f\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306e\u30b5\u30a4\u30ba\u3068\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u306b\u5408\u305b\u3066\u8abf\u6574\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-04.jpg\" alt=\"graphical user interface, table\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3068\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u30e1\u30bd\u30c3\u30c9\u3092\u5909\u63db\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u5909\u63db\u3055\u308c\u305f\u6d41\u91cf\u306f\u7de8\u96c6\u53ef\u80fd\u306a\u30d5\u30a3\u30fc\u30eb\u30c9\u3067\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4ee5\u4e0b\u306e\u300c\u7d50\u679c\u300d\u30bb\u30af\u30b7\u30e7\u30f3\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u5909\u63db\u3055\u308c\u305f\u6d41\u91cf\u3092\u5909\u66f4\u3057\u3066\u5206\u6790\u7a2e\u306e\u4fdd\u6301\u6642\u9593\u3068\u5206\u96e2\u306b\u3069\u306e\u3088\u3046\u306b\u5f71\u97ff\u3059\u308b\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001Pro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u6307\u5b9a\u3055\u308c\u305f\u4e00\u9023\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u5bfe\u3057\u3066\u7406\u60f3\u7684\u306a\u7bc4\u56f2\u5185\u306b\u3042\u308b\u6d41\u91cf\u306e\u307f\u3092\u8fd4\u305d\u3046\u3068\u3057\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u5b9f\u969b\u306b\u8a08\u7b97\u306b\u3088\u308a\u5909\u63db\u3055\u308c\u305f\u6d41\u91cf\u304c\u305d\u308c\u3089\u306e\u5024\u3092\u5916\u308c\u305f\u5834\u5408\u3001Pro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u6d41\u91cf\u304c\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u5bfe\u3057\u3066\u671b\u307e\u3057\u3044\u7bc4\u56f2\u5185\u306b\u306a\u308b\u3088\u3046\u306b\u8abf\u6574\u3057\u307e\u3059\u3002 \u3053\u306e\u6a5f\u80fd\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u7528\u8a9e\u96c6\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u7d50\u679c\u306e\u89e3\u91c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u3053\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u306f\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u5909\u63db\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u4e88\u60f3\u3055\u308c\u308b\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3068\u80cc\u5727\u306e\u5909\u5316\u3092\u793a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30e6\u30fc\u30b6\u30fc\u56fa\u6709\u306e\u6ce8\u5165\u56de\u6570\u3067\u6642\u9593\u3068\u6eb6\u5a92\u306e\u7bc0\u7d04\u3092\u8a08\u7b97\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002 \u3053\u306e\u4f8b\u3067\u306f\u3001\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u304c\u534a\u5206\u306e\u5727\u529b\u3001\u534a\u5206\u306e\u5206\u6790\u6642\u9593\u3001\u305d\u3057\u3066\u5143\u306e\u30e1\u30bd\u30c3\u30c9\u306e1\/4\u306e\u6eb6\u5a92\u6d88\u8cbb\u91cf\u3067\u7d50\u679c\u3092\u751f\u6210\u3059\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u91cd\u8981\u306a\u5316\u5408\u7269\u306e\u9593\u306f\u307e\u3060\u5341\u5206\u306b\u5206\u96e2\u3057\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\uff1f \u300c\u91cd\u8981\u306a\u30d4\u30fc\u30af\u306e\u5206\u96e2\u5ea6\u300d\u3068\u300c\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u300d\u306e\u30d5\u30a3\u30fc\u30eb\u30c9\u3067\u306f\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u30e1\u30bd\u30c3\u30c9\u304c\u8a31\u5bb9\u53ef\u80fd\u306a\u7d50\u679c\u3092\u63d0\u4f9b\u3059\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5143\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u7d50\u679c\u3092\u518d\u78ba\u8a8d\u3059\u308b\u3068\u3001\u6700\u5c0f\u306e\u5206\u96e2\u5ea6\u3092\u6709\u3059\u308b\u91cd\u8981\u306a\u5316\u5408\u7269\u30da\u30a2\u306f\u30e2\u30eb\u30d2\u30cd(\u30d4\u30fc\u30af1)\u3068\u30d2\u30c9\u30ed\u30e2\u30eb\u30db\u30f3(\u30d4\u30fc\u30af2)\u3067\u3042\u308a\u3001\u5143\u306e\u5206\u96e2\u5ea6\u306f4.88\u3067\u3059\u3002 \u3053\u306e\uff12\u3064\u306e\u30d4\u30fc\u30af\u306f\u304b\u306a\u308a\u3088\u304f\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u5143\u306e\u30ab\u30e9\u30e0\u3068\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u306e\u9593\u306e\u5168\u4f53\u7684\u306a\u52b9\u7387\u306e\u4f4e\u4e0b\u306f\u5206\u96e2\u3092\u72a0\u7272\u306b\u3057\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308b\u3068\u4e88\u6e2c\u3067\u304d\u307e\u3059\u304c\u30014.88\u3068\u3044\u3046\u5143\u306e\u5206\u96e2\u5ea6\u3092\u9069\u5207\u306a\u30d5\u30a3\u30fc\u30eb\u30c9\u306b\u5165\u529b\u3057\u3001\u4e88\u6e2c\u5206\u96e2\u5ea6\u3092\u898b\u308b\u3060\u3051\u3067\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059(\u56f35)\u3002 \u307e\u305f\u3001\u30e2\u30eb\u30d2\u30cd\u306e\u4fdd\u6301\u6642\u9593\u3092\u5165\u529b\u3057\u3066\u3001\u65b0\u3057\u3044\u6761\u4ef6\u4e0b\u3067\u4fdd\u6301\u6642\u9593\u304c\u3069\u306e\u3088\u3046\u306b\u5909\u5316\u3059\u308b\u304b\u3092\u628a\u63e1\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 5:<\/strong>\u00a0\u7d50\u679c\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u3092\u5229\u7528\u3057\u3066\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u4e0b\u3067\u91cd\u8981\u306a\u5206\u96e2\u5ea6\u3068\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3316-05.jpg\" alt=\"graphical user interface, application\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5168\u7406\u8ad6\u6bb5\u6570\u306e\u4f4e\u4e0b\u306b\u3088\u3063\u3066\u4e88\u6e2c\u3055\u308c\u305f\u3088\u3046\u306b\u3001\u3053\u306e\uff12\u3064\u306e\u91cd\u8981\u306a\u30da\u30a2\u306e\u9593\u306e\u5206\u96e2\u5ea6\u306f\u4f4e\u4e0b\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u304c\u3001\u65b0\u3057\u3044\u5206\u96e2\u5ea6\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u306b\u5fc5\u8981\u306a\u5024 (R = 1.5)\u3092\u306f\u308b\u304b\u306b\u8d85\u3048\u3066\u3044\u308b\u3053\u3068\u304c\u4e88\u6e2c\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3082\u308f\u304b\u308a\u307e\u3059\u3002 \u3053\u308c\u306b\u57fa\u3065\u3044\u3066\u3001\u5909\u63db\u3055\u308c\u305f\u6761\u4ef6\u3067\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3082\u3001\u4e00\u756a\u65e9\u304f\u8fd1\u63a5\u3057\u3066\u6eb6\u51fa\u3059\u308b\u91cd\u8981\u306a\u5316\u5408\u7269\u30da\u30a2\u304c\u4f9d\u7136\u3068\u3057\u3066\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3001\u6b8b\u308a\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3082\u554f\u984c\u306a\u3044\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3068\u7d50\u8ad6\u4ed8\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u7406\u8ad6\u3092\u305d\u306e\u307e\u307e\u306b\u3057\u3066\u306f\u3044\u3051\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f36\u306f\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u304a\u3088\u3073\u5909\u63db\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u4f7f\u7528\u3057\u3066\u5206\u6790\u3055\u308c\u305f\u540c\u3058\u5316\u5408\u7269\u30bb\u30c3\u30c8\u306e\u5b9f\u9a13\u7d50\u679c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 6:<\/strong>\u00a0\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u5909\u63db\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u7528\u3044\u3066\u751f\u6210\u3055\u308c\u305f\u5b9f\u9a13\u7d50\u679c\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0757.png\" alt=\"Translation Conditions for Method Translator Article: Drugs of Abuse on Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0757<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine<\/a><\/td><td class=\"oth\">0.66<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone<\/a><\/td><td class=\"oth\">0.88<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">184.9<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/467-15-2\/Norcodeine\" target=\"_blank\" rel=\"noopener\">Norcodeine<\/a><\/td><td class=\"oth\">1.15<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">151.9<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norhydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5083-62-5\/Norhydrocodone\" target=\"_blank\" rel=\"noopener\">Norhydrocodone<\/a><\/td><td class=\"oth\">1.51<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">199.0<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6\u03b2-Naltrexol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/49625-89-0\/6\u03b2-Naltrexol\" target=\"_blank\" rel=\"noopener\">6\u03b2-Naltrexol<\/a><\/td><td class=\"oth\">2.0<\/td><td class=\"oth\">344.3<\/td><td class=\"oth\">326.1<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27203-92-5\/Tramadol\" target=\"_blank\" rel=\"noopener\">Tramadol<\/a><\/td><td class=\"oth\">2.55<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">58.0<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Normeperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-17-8\/Normeperidine\" target=\"_blank\" rel=\"noopener\">Normeperidine<\/a><\/td><td class=\"oth\">2.74<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">160.2<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-52-8\/Mirtazapine\" target=\"_blank\" rel=\"noopener\">Mirtazapine<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">195.1<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clozapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5786-21-0\/Clozapine\" target=\"_blank\" rel=\"noopener\">Clozapine<\/a><\/td><td class=\"oth\">3.26<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">271.1<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentazocine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/359-83-1\/Pentazocine\" target=\"_blank\" rel=\"noopener\">Pentazocine<\/a><\/td><td class=\"oth\">3.3<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">218.1<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34084-50-9\/7-Aminoflunitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoflunitrazepam<\/a><\/td><td class=\"oth\">3.54<\/td><td class=\"oth\">284.1<\/td><td class=\"oth\">135.0<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54910-89-3\/Fluoxetine\" target=\"_blank\" rel=\"noopener\">Fluoxetine<\/a><\/td><td class=\"oth\">4.02<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">148.0<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1977-10-2\/Loxapine\" target=\"_blank\" rel=\"noopener\">Loxapine<\/a><\/td><td class=\"oth\">4.18<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">271.1<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EMDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102177-18-4\/EMDP\" target=\"_blank\" rel=\"noopener\">EMDP<\/a><\/td><td class=\"oth\">4.38<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">235.2<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thioridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-52-2\/Thioridazine\" target=\"_blank\" rel=\"noopener\">Thioridazine<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">126.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A52\" rel=\"noopener\">cat.# 9309A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>0.5-10 \u00b5g\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>85<\/td><td>15<\/td><\/tr><tr><td>3.20<\/td><td>0.5<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>4.90<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A standard mix with 15 drugs of abuse was prepared in the concentrations ranging from 500-10,000 ng\/mL in water. The solution was vortexed at 3000 rpm for 10 seconds to mix, and the supernatant was injected for LC-MS\/MS analysis.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A52<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0757.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u30e1\u30bd\u30c3\u30c9\u3092\u4f7f\u7528\u3057\u305f\u5b9f\u969b\u306e\u5206\u6790\u3067\u306f\u3001\u30e2\u30eb\u30d2\u30cd\u306e\u4fdd\u6301\u6642\u9593\u306f0.66\u5206\u3067\u3042\u308a\u3001LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u4e88\u6e2c\u4fdd\u6301\u6642\u9593\u3088\u308a\u3082\u308f\u305a\u304b0.01\u5206\u9577\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002 \u30e2\u30eb\u30d2\u30cd\u3068\u30d2\u30c9\u30ed\u30e2\u30eb\u30db\u30f3\u3068\u306e\u9593\u306e\u5206\u96e2\u5ea6\u306f\u3001R=3.07\u3067\u3042\u308b\u3068\u5b9f\u9a13\u7684\u306b\u6c7a\u5b9a\u3055\u308c\u307e\u3057\u305f\u3002\u4e88\u6e2c\u5206\u96e2\u5ea6\u306fR=2.80\u3067\u3001\u304a\u3088\u305d10%\u306e\u9055\u3044\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u91cd\u8981\u306a\u30da\u30a2\u306e\u5206\u96e2\u5ea6\u306b\u95a2\u3057\u3066\u306f\u3001\u63a7\u3048\u3081\u306a\u65b9\u5411\u3067\u8aa4\u308a\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u4e88\u6e2c\u3088\u308a\u3082\u3055\u3089\u306b\u512a\u308c\u305f\u5206\u96e2\u80fd\u3092\u793a\u3059\u5b9f\u9a13\u7d50\u679c\u3068\u306a\u308a\u3001\u3053\u306e\u4f8b\u3067\u306f\u3001\u91cd\u8981\u306a\u30da\u30a2\u306e\u5206\u96e2\u3092\u640d\u3046\u3053\u3068\u3092\u61f8\u5ff5\u305b\u305a\u306b\u3001\u5143\u306e\u30ab\u30e9\u30e0\u304b\u3089\u79fb\u884c\u3057\u3066\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3068\u5909\u63db\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u63a1\u7528\u3057\u3066\u3082\u5b89\u5168\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u91cd\u8981\u306a\u30da\u30a2\u304c\u5143\u306e\u6761\u4ef6\u4e0b\u3067R=2\u306e\u5206\u96e2\u5ea6\u3092\u6709\u3057\u3066\u3044\u305f\u5834\u5408\u3001\u3053\u306e\u7279\u5b9a\u306e\u5909\u63db(100mm\u00d73.0mm\u30012.7\u03bcm\u304b\u308950mm\u00d72.1mm\u30012.7\u03bcm)\u306f\u3001\u5909\u63db\u6761\u4ef6\u4e0b\u3067\u306f\u5171\u6eb6\u51fa\u3092\u56de\u907f\u3059\u308b\u306e\u306b\u5341\u5206\u306a\u5206\u96e2\u5ea6\u3092\u6709\u3057\u3066\u3044\u306a\u3044\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3067\u3057\u3087\u3046(\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u3053\u308c\u3089\u306e\u6761\u4ef6\u4e0b\u3067R=1.15\u3092\u4e88\u6e2c\u3057\u307e\u3059)\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30dc\u304c\u30e1\u30bd\u30c3\u30c9\u3092\u3042\u308b\u30ab\u30e9\u30e0\u304b\u3089\u5225\u306e\u30ab\u30e9\u30e0\u306b\u5909\u63db\u3059\u308b\u3053\u3068\u306b\u95a2\u5fc3\u3092\u6301\u3064\u7406\u7531\u306f\u305f\u304f\u3055\u3093\u3042\u308a\u307e\u3059\u3002Restek\u306ePro&nbsp;<em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306e\u3088\u3046\u306a\u7121\u6599\u306e\u30aa\u30f3\u30e9\u30a4\u30f3LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u6570\u6642\u9593\u3084\u6570\u65e5\u3067\u306f\u306a\u304f\u3001\u6570\u5206\u3067\u305d\u306e\u9078\u629e\u80a2\u3092\u8abf\u3079\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u591a\u304f\u306e\u5834\u5408\u3001LC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306f\u3001\u3053\u3053\u306b\u793a\u3057\u305f\u4f8b\u306e\u3088\u3046\u306b\u3001\u6642\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u3001\u3082\u3057\u304f\u306f\u6eb6\u5a92\u3092\u7bc0\u7d04\u3057\u3088\u3046\u3068\u3059\u308b\u30e9\u30dc\u3092\u6271\u3063\u305f\u3082\u306e\u3067\u3059\u304c\u3001\u4ed6\u306e\u5834\u5408\u306b\u3082\u6709\u7528\u3067\u3059\u3002\u6700\u5148\u7aef\u306eUHPLC\u6a5f\u5668\u3067\u958b\u767a\u3055\u308c\u3066\u3046\u307e\u304f\u3044\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u3092\u3001\u5f93\u6765\u306eHPLC\u6a5f\u5668\u3092\u5099\u3048\u305f\u88fd\u9020\u65bd\u8a2d\u7528\u306b\u5909\u63db\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u3088\u308a\u3082\u5927\u304d\u306a\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u540c\u3058\u7d50\u679c\u304c\u9054\u6210\u3067\u304d\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u3057\u3066\u3053\u306e\u4f8b\u3067\u306f\u3001\u30e9\u30dc\u306f\u81ea\u4fe1\u3092\u6301\u3063\u3066\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u3092\u304a\u3053\u306a\u3044\u3001\u5206\u6790\u6642\u9593\u3092\u534a\u5206\u306b\u77ed\u7e2e\u3057\u3001\u534a\u5206\u306e\u80cc\u5727\u3067\u64cd\u4f5c\u3057(\u3053\u308c\u306f\u88c5\u7f6e\u3092\u6271\u3044\u3084\u3059\u304f\u3057\u307e\u3059)\u3001\u5f93\u6765\u6d88\u8cbb\u3057\u3066\u3044\u305f\u91cf\u306e1\/4\u306e\u6eb6\u5a92\u3057\u304b\u4f7f\u7528\u305b\u305a\u306b\u3001\u611f\u5ea6\u3082\u540c\u69d8\u306b\u5411\u4e0a\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002 \u3068\u3066\u3082\u3088\u3044\u53d6\u308a\u7d44\u307f\u3060\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3042\u306a\u305f\u306e\u30e9\u30dc\u306b\u306f\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306e\u9700\u8981\u306f\u3042\u308a\u307e\u3059\u304b? \u305d\u306e\u5834\u5408\u306f\u3001Restek Pro EZLC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u3054\u4e0d\u660e\u306a\u70b9\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002 \u30e1\u30bd\u30c3\u30c9\u5909\u63db\u304c\u3046\u307e\u304f\u3044\u304d\u307e\u3059\u3088\u3046\u306b\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A1E\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A1E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30e1\u30bd\u30c3\u30c9\u3092\u3088\u308a\u5c0f\u3055\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u5909\u66f4\u3059\u308b\u3068\u3001\u6642\u9593\u3001\u6eb6\u5a92\u3001\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u3092\u7bc0\u7d04\u3067\u304d\u307e\u3059\u304c\u3001\u9069\u5207\u306aLC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002Pro\u00a0EZLC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b7\u30ca\u30ea\u30aa\u3092\u7c21\u5358\u306b\u30c6\u30b9\u30c8\u3057\u6210\u529f\u3092\u53ce\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":89939,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2343,2343],"ppma_author":[2814,414],"class_list":["post-43693","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR3316-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43693"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43693\/revisions"}],"predecessor-version":[{"id":69162,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43693\/revisions\/69162"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/89939"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43693"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43693"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43693"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43693"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43693"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43693"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43693"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43693"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}