{"id":43699,"date":"2022-10-11T00:00:00","date_gmt":"2022-10-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japan-accelerate-lc-ms-ms-method-development-using-the-pro-ezlc-chromatogram-modeler\/"},"modified":"2025-11-25T22:03:49","modified_gmt":"2025-11-25T22:03:49","slug":"japan-accelerate-lc-ms-ms-method-development-using-the-pro-ezlc-chromatogram-modeler","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3915-ja\/japan-accelerate-lc-ms-ms-method-development-using-the-pro-ezlc-chromatogram-modeler","title":{"rendered":"Pro\u202f<em>EZ<\/em>\u202fLC Chromatogram Modeler\u3092\u4f7f\u7528\u3057\u305fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u52a0\u901f"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u7cbe\u5ea6\u306a\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u80fd\u306b\u3088\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u6642\u9593\u3068\u30b3\u30b9\u30c8\u3092\u5927\u5e45\u306b\u524a\u6e1b<\/li>\n\n\n\n<li>\u30e9\u30dc\u306e\u88c5\u7f6e\u3092\u7a3c\u50cd\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u7528\u3044\u3066LC\u30ab\u30e9\u30e0\u3084\u5206\u6790\u6761\u4ef6\u306e\u691c\u8a0e\u30fb\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u304c\u53ef\u80fd<\/li>\n\n\n\n<li>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u3067\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u5fae\u8abf\u6574\u3057\u3001\u52b9\u679c\u3092\u5373\u78ba\u8a8d\u3001\u91cd\u8981\u306a\u5206\u96e2\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u6700\u9069\u5316<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306f\u3001LC-MS\/MS\u30e9\u30dc\u306b\u304a\u3044\u3066\u6700\u3082\u91cd\u8981\u3067\u3042\u308b\u4e00\u65b9\u3001\u6642\u9593\u3068\u30b3\u30b9\u30c8\u304c\u304b\u304b\u308b\u4f5c\u696d\u306e 1 \u3064\u3067\u3059\u3002\u5f93\u6765\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u9a13\u7684\u306b\u78ba\u7acb\u3057\u3001\u30eb\u30fc\u30c1\u30f3\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u3067\u306e\u9ad8\u3044\u518d\u73fe\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u591a\u304f\u306e\u6642\u9593\u3084\u8a2d\u5099\u3001\u5c02\u9580\u77e5\u8b58\u304c\u5fc5\u8981\u3067\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u4eca\u304b\u3089\u3054\u7d39\u4ecb\u3059\u308bRestek\u306ePro <em>EZ<\/em>LC Chromatogram Modeler\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\uff09\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u77ed\u6642\u9593\u3067\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u202f\u3002\u3053\u306e\u7121\u6599\u306eChromatogram Modeler\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30e9\u30dc\u3067\u88c5\u7f6e\u3092\u5c02\u6709\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u8fc5\u901f\u304b\u3064\u7c21\u5358\u306b\u5206\u96e2\u30e2\u30c7\u30eb\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u5177\u4f53\u7684\u306b15\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u3092\u4f8b\u3068\u3057\u3066\u7528\u3044\u3066\u3001\u7121\u6599\u3067\u3042\u308a\u306a\u304c\u3089\u3055\u307e\u3056\u307e\u306a\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u304c\u53ef\u80fd\u306aChromatogram Modeler\u304c\u5b9f\u73fe\u3059\u308b\u3001LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u7c21\u7d20\u5316\u304a\u3088\u3073\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u3059\u308b\u65b9\u6cd5\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e9\u30dc\u30d9\u30fc\u30b9\u3068Pro\u202f<em>EZ<\/em>LC\u3067\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30dc\u30d9\u30fc\u30b9\uff08\u88c5\u7f6e\u3092\u4f7f\u7528\uff09\u306e\u5834\u5408\u3067\u3082\u3001Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3067\u3082\u3001LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u6700\u521d\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u5206\u6790\u76ee\u6a19\u3092\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u611f\u5ea6\u3001\u5206\u6790\u6642\u9593\u3001\u5206\u96e2\u5ea6\u306e\u8981\u4ef6\u306f\u3001\u30e9\u30dc\u3084\u5206\u6790\u624b\u6cd5\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u901f\u5ea6\u3092\u72a0\u7272\u306b\u3057\u3066\u3067\u3082\u3001\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u306e\u5206\u96e2\u5ea6\u3092\u78ba\u4fdd\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3082\u3042\u308b\u3067\u3057\u3087\u3046\u3002\u4e00\u65b9\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u76ee\u6a19\u9054\u6210\u3092\u7b2c\u4e00\u512a\u5148\u4e8b\u9805\u3068\u3057\u3066\u3001\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u304c\u5fc5\u8981\u3068\u3055\u308c\u308b\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u30ef\u30fc\u30af\u306b\u304a\u3044\u3066\u306f\u3001\u5206\u6790\u6761\u4ef6\u306e\u958b\u767a\u3092\u59cb\u3081\u308b\u524d\u306b\u3001\u5404\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u3059\u308b\u5fc5\u8981\u8981\u4ef6\u3092\u7cbe\u67fb\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a\u30e9\u30dc\u30d9\u30fc\u30b9\u306eLC-MS\/MS \u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u306b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6761\u4ef6\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3001\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u624b\u9806\u306e\u6700\u9069\u5316\u306b\u8cbb\u3084\u3059\u6642\u9593\u304c\u542b\u307e\u308c\u307e\u3059 (<strong>Figure 1<\/strong>)\u3002Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u3092\u4f7f\u7528\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306f\u3001\u5206\u96e2\u306e\u6700\u9069\u5316\u3001\u30d7\u30ec\u30ab\u30fc\u30b5\u304a\u3088\u3073\u30d7\u30ed\u30c0\u30af\u30c8\u30a4\u30aa\u30f3\u306e\u7279\u5b9a\u3001\u304a\u3088\u3073\u5404\u5316\u5408\u7269\u306e\u6b63\u3057\u3044\u30e2\u30fc\u30c9\u306e\u9078\u629e\u306b\u304b\u304b\u308b\u4f5c\u696d\u304c\u3001\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u6570\u5206\u3067\u5b8c\u4e86\u3057\u307e\u3059\u3002Pro <em>EZ<\/em>LC\u3067\u3042\u308c\u3070\u3001\u7c21\u5358\u306a\u5165\u529b\u3060\u3051\u3067\u30b7\u30e5\u30df\u30ec\u30fc\u30b7\u30e7\u30f3\u304c\u5b8c\u7d50\u3057\u307e\u3059\u3002LC \u30e2\u30c7\u30eb\u306f\u3001Restek \u306e\u79d1\u5b66\u8005\u306b\u3088\u3063\u3066\u3059\u3067\u306b\u751f\u6210\u3055\u308c\u305f\u5805\u7262\u306a\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3068\u5b9f\u9a13\u30c7\u30fc\u30bf\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc \u30e1\u30bd\u30c3\u30c9\u3092\u8fc5\u901f\u306b\u6700\u9069\u5316\u3067\u304d\u308b\u305f\u3081\u3001MS\u30d1\u30e9\u30e1\u30fc\u30bf\u3084\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u624b\u9806\u306e\u6700\u9069\u5316\u306a\u3069\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u4ed6\u306e\u5074\u9762\u306b\u3088\u308a\u591a\u304f\u306e\u6642\u9593\u3092\u8cbb\u3084\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u6642\u9593\u306e\u7bc0\u7d04\u306f\u30e1\u30bd\u30c3\u30c9\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30d5\u30a7\u30fc\u30ba\u3078\u306e\u901f\u3084\u304b\u306a\u79fb\u884c\u3092\u53ef\u80fd\u3068\u3057\u3001\u7d50\u679c\u3068\u3057\u3066\u3001\u30eb\u30fc\u30c1\u30f3\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u3068\u3044\u3063\u305f\u5b9f\u969b\u306e\u4f5c\u696d\u3092\u3088\u308a\u65e9\u304f\u958b\u59cb\u3067\u304d\u308b\u3053\u3068\u3082\u610f\u5473\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> LC-MS\/MS \u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u306b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6761\u4ef6\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306e\u8a2d\u5b9a\u3001\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u624b\u9806\u306e\u6700\u9069\u5316\u304c\u5fc5\u8981\u3067\u3059\u3002Pro\u202f<em>EZ<\/em>LC Modeler\u3092\u4f7f\u7528\u3057\u3066\u3055\u307e\u3056\u307e\u306a\u6761\u4ef6\u3092\u4eee\u60f3\u7684\u306b\u5b9f\u884c\u3059\u308b\u3053\u3068\u3067\u3001\u6642\u9593\u306e\u304b\u304b\u308b\u30e9\u30dc\u3067\u306e\u4f5c\u696d\u3092\u884c\u308f\u305a\u306b\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc \u30e1\u30bd\u30c3\u30c9\u3092\u6570\u5206\u3067\u6700\u9069\u5316\u3067\u304d\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"493\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/T0-1-figure-article-GNAR3915-01-2-1024x493.png\" alt=\"\" class=\"wp-image-29049\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/T0-1-figure-article-GNAR3915-01-2-1024x493.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-1-figure-article-GNAR3915-01-2-300x144.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-1-figure-article-GNAR3915-01-2-768x369.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-1-figure-article-GNAR3915-01-2-1536x739.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-1-figure-article-GNAR3915-01-2.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u96e2\u5ea6\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3001\u611f\u5ea6\u306b\u95a2\u3059\u308b\u5206\u6790\u76ee\u6a19\u304c\u8a2d\u5b9a\u3055\u308c\u305f\u5f8c\u306f\u3001\u30e9\u30dc\u3067\u6700\u9069\u306a\u6761\u4ef6\u3092\u691c\u8a3c\u3059\u308b\u305f\u3081\u3001\u5b9f\u969b\u306b\u30e1\u30bd\u30c3\u30c9\u4f5c\u6210\u3092\u7d42\u4e86\u3059\u308b\u307e\u3067\u306b\u6570\u65e5\u304b\u3089\u6570\u9031\u9593\u3092\u8cbb\u3084\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u969b\u3001\u88c5\u7f6e\u3001\u30ab\u30e9\u30e0\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u95a2\u9023\u30ea\u30bd\u30fc\u30b9\u306e\u3001\u5225\u4f5c\u696d\u3067\u306e\u5229\u7528\u306f\u5236\u9650\u3055\u308c\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u4f5c\u696d\u8005\u306f\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u305f\u308a\u3001\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u305f\u308a\u3001\u5206\u6790\u7d50\u679c\u3092\u5f85\u3064\u3053\u3068\u306a\u304f\u3001\u7c21\u5358\u304b\u3064\u901f\u3084\u304b\u306b\u30d1\u30e9\u30e1\u30fc\u30bf\u5909\u66f4\u306e\u5f71\u97ff\u3092\u8abf\u67fb\u30fb\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u7570\u306a\u308b\u56fa\u5b9a\u76f8\u304a\u3088\u3073\u30b5\u30a4\u30ba\u3068\u3044\u3063\u305f\u30ab\u30e9\u30e0\u306b\u95a2\u308f\u308b\u8a55\u4fa1\u3082\u975e\u5e38\u306b\u7c21\u5358\u306b\u5b9f\u65bd\u3067\u304d\u308b\u305f\u3081\u3001\u624b\u5143\u306b\u306a\u3044\u30ab\u30e9\u30e0\u3067\u3082\u3001\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3067\u78ba\u8a8d\u3001\u305d\u308c\u3089\u304c\u5bfe\u8c61\u306e\u6210\u5206\u306b\u5bfe\u3057\u3066\u6a5f\u80fd\u3059\u308b\u304b\u3069\u3046\u304b\u3001\u8cfc\u5165\u524d\u306b\u4e8b\u524d\u78ba\u8a8d\u3092\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u611f\u5ea6\u306e\u8a55\u4fa1\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u3001MS\u306e\u6700\u9069\u5316\u3001\u304a\u3088\u3073\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u306e\u8a55\u4fa1\u306f\u4f9d\u7136\u3068\u3057\u3066\u30e9\u30dc\u3067\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001<strong>Figure 2<\/strong>\u306f\u3001\u7121\u6599\u306ePro\u202f<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306e\u5229\u70b9\uff08\u6642\u9593\u3084\u30ea\u30bd\u30fc\u30b9\u306e\u7bc0\u7d04\u3001\u7c21\u4fbf\u3055\uff09\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u3092\u4f7f\u7528\u3057\u305f\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306f\u3001\u30e9\u30dc\u30d9\u30fc\u30b9\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3088\u308a\u3082\u8fc5\u901f\u304b\u3064\u7c21\u5358\u3067\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"467\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/T0-2-figure-article-GNAR3915-02-v2-1024x467.png\" alt=\"\" class=\"wp-image-29061\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/T0-2-figure-article-GNAR3915-02-v2-1024x467.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-2-figure-article-GNAR3915-02-v2-300x137.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-2-figure-article-GNAR3915-02-v2-768x350.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-2-figure-article-GNAR3915-02-v2-1536x701.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/T0-2-figure-article-GNAR3915-02-v2.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u52b9\u679c\u306f\u3042\u308b?\u202f\u8a66\u3057\u3066\u307f\u307e\u3057\u3087\u3046!<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30e9\u30dc\u30d9\u30fc\u30b9\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3088\u308a\u3082\u8fc5\u901f\u306b\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u9069\u5316\u304c\u53ef\u80fd\u3067\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u305d\u306e\u5229\u70b9\u306fModeler\u304c\u5b9f\u969b\u306e\u7d50\u679c\u3092\u6b63\u78ba\u306b\u4e88\u6e2c\u3059\u308b\u5834\u5408\u306b\u306e\u307f\u5b9f\u73fe\u3055\u308c\u308b\u3068\u3044\u3046\u70b9\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u4f8b\u3068\u3057\u3066\u3001Pro <em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3066\u4e71\u7528\u85ac\u7269\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u3001\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u3068\u30e9\u30dc\u3067\u751f\u6210\u3055\u308c\u305f\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u5316\u5408\u7269\u30bf\u30d6\u3067\u5316\u5408\u7269\u540d\u3068\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306f\u3001<strong>\u202f[\u5316\u5408\u7269]<\/strong>\u3001<strong>\u202f[\u5206\u6790\u6761\u4ef6]<\/strong>\u3001\u304a\u3088\u3073\u202f<strong>[My\u202f<em>EZ<\/em>LC] <\/strong>\u306e 3 \u3064\u306e\u30bf\u30d6\u4ed8\u304d\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u202f\u3002\u4f5c\u696d\u306f\u202f[<strong>\u5316\u5408\u7269<\/strong>]\u202f\u30bf\u30d6\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u3002<strong>Figure 3<\/strong>\u306f\u3001\u30e2\u30c7\u30eb\u306e\u4f5c\u6210\u306b\u4f7f\u7528\u3059\u308b\u5165\u529b\u30d5\u30a3\u30fc\u30eb\u30c9\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305a\u6700\u521d\u306b\u3001\u202f<strong>\u5316\u5408\u7269\u30af\u30e9\u30b9(Compound Class) <\/strong>(3A) \u3092\u9078\u629e\u3057\u3001\u6b21\u306b\u500b\u3005\u306e<strong>\u5316\u5408\u7269(Compound Name) <\/strong>(3B) \u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u5bfe\u8c61\u5316\u5408\u7269\u306e\u30ea\u30b9\u30c8\u3092\u4f5c\u6210\u3057\u307e\u3059\u3002\u5bfe\u8c61\u5316\u5408\u7269\u306f\u65e2\u5b58\u30ea\u30b9\u30c8\u3092\u30b9\u30af\u30ed\u30fc\u30eb\u3001\u307e\u305f\u306f\u3001<strong>\u691c\u7d22(Search)<\/strong>\u30dc\u30c3\u30af\u30b9\u306b\u5316\u5408\u7269\u540d (\u307e\u305f\u306f CAS \u756a\u53f7) \u3092\u5165\u529b\u3057\u3066\u9078\u629e\u3092\u884c\u3044\u307e\u3059(3C) \u3002\u30c4\u30fc\u30eb\u5185\u3067\u306f\u30d8\u30eb\u30d7\u30d5\u30a1\u30a4\u30eb (3D) \u3082\u5229\u7528\u3067\u304d\u3001\u7279\u5b9a\u306e\u30bf\u30b9\u30af\u306b\u3064\u3044\u3066\u306e\u8a73\u7d30\u306a\u624b\u9806\u3082\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u202f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Pro\u202f<em>\u202fEZ<\/em>LC Chromatogram Modeler\u306e\u202f[\u5316\u5408\u7269]\u202f\u30bf\u30d6 (\u8d64\u3067\u56f2\u3093\u3060) \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3068\u5165\u529b\u30d5\u30a3\u30fc\u30eb\u30c9\u306e\u8aac\u660e: <strong>3A<\/strong>\u5316\u5408\u7269\u30af\u30e9\u30b9\u306e\u9078\u629e\u30ea\u30b9\u30c8, <strong>3B<\/strong>\u5316\u5408\u7269\u30ea\u30b9\u30c8, <strong>3C<\/strong>\u691c\u7d22\u30dc\u30c3\u30af\u30b9, <strong>3D<\/strong>\u30d8\u30eb\u30d7 \u30d5\u30a1\u30a4\u30eb, <strong>3E<\/strong>\u540c\u91cd\u4f53\u5206\u96e2\u30a2\u30e9\u30fc\u30c8, <strong>3F<\/strong>\u56fa\u5b9a\u76f8\u9078\u629e\u30ea\u30b9\u30c8, <strong>3G<\/strong>\u30e2\u30c7\u30eb\u751f\u6210\u30dc\u30bf\u30f3, <strong>3H<\/strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc\u9818\u57df<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-03.jpg\" alt=\"figure-article-GNAR3915-03.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u304b\u3089\u3001\u6b21\u306e15\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u3092\u4f8b\u306b\u7528\u3044\u3066\u5b9f\u969b\u306e\u52d5\u4f5c\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u9818\u57df\u306e\u5e83\u3044\u7bc4\u56f2\u3001\u8a00\u3044\u63db\u3048\u308b\u3068\u5e45\u5e83\u3044\u4fdd\u6301\u6642\u9593 (\u6eb6\u51fa\u306e\u65e9\u3044\u5316\u5408\u7269\u304b\u3089\u9045\u3044\u5316\u5408\u7269\u307e\u3067) \u3092\u30ab\u30d0\u30fc\u3057\u3001\u540c\u91cd\u4f53\u4ee5\u5916\u306b\u3082\u5206\u96e2\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u3092\u542b\u3093\u3067\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u30b3\u30c7\u30a4\u30f3<\/li>\n\n\n\n<li>N-\u30c7\u30b9\u30e1\u30c1\u30eb\u30bf\u30da\u30f3\u30bf\u30c9\u30fc\u30eb<\/li>\n\n\n\n<li>O-\u30c7\u30b9\u30e1\u30c1\u30eb-\u30b7\u30b9-\u30c8\u30e9\u30de\u30c9\u30fc\u30eb<\/li>\n\n\n\n<li>\u30c7\u30bd\u30e2\u30eb\u30d2\u30cd<\/li>\n\n\n\n<li>\u30c7\u30ad\u30b9\u30c8\u30ed\u30e1\u30c8\u30eb\u30d5\u30a1\u30f3<\/li>\n\n\n\n<li>\u30b8\u30d2\u30c9\u30ed\u30b3\u30c7\u30a4\u30f3<\/li>\n\n\n\n<li>\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3<\/li>\n\n\n\n<li>\u30e2\u30eb\u30d2\u30cd<\/li>\n\n\n\n<li>\u30e2\u30eb\u30d2\u30cd-N-\u30aa\u30ad\u30b7\u30c9<\/li>\n\n\n\n<li>\u30ce\u30eb\u30b3\u30c7\u30a4\u30f3<\/li>\n\n\n\n<li>\u30ce\u30eb\u30e2\u30eb\u30d2\u30cd<\/li>\n\n\n\n<li>\u30ce\u30eb\u30aa\u30ad\u30b7\u30b3\u30c9\u30f3<\/li>\n\n\n\n<li>\u30aa\u30ad\u30b7\u30e2\u30eb\u30d5\u30a9\u30f3<\/li>\n\n\n\n<li>\u30da\u30f3\u30bf\u30be\u30b7\u30f3<\/li>\n\n\n\n<li>\u30da\u30f3\u30bf\u30be\u30b7\u30f3<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30ea\u30b9\u30c8\u306b\u306f\u3001\u540c\u3058\u5206\u5b50\u91cf\u3092\u5171\u6709\u3059\u308b4\u3064\u306e\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u30b0\u30eb\u30fc\u30d7\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059: \u30c7\u30bd\u30e2\u30eb\u30d2\u30cd\/\u30c7\u30ad\u30b9\u30c8\u30ed\u30e1\u30c8\u30eb\u30d5\u30a1\u30f3\/\u30ce\u30eb\u30e2\u30eb\u30d2\u30cd (m\/z 272)\u3002\u30b8\u30d2\u30c9\u30ed\u30b3\u30c7\u30a4\u30f3\/\u30e2\u30eb\u30d2\u30cd-N-\u30aa\u30ad\u30b7\u30c9\/\u30ce\u30eb\u30aa\u30ad\u30b7\u30b3\u30c9\u30f3\/\u30aa\u30ad\u30b7\u30e2\u30eb\u30d5\u30a9\u30f3 (m\/z 302);\u202f\u30e2\u30eb\u30d2\u30cd\/\u30ce\u30eb\u30b3\u30c7\u30a4\u30f3\/\u30da\u30f3\u30bf\u30be\u30b7\u30f3 (m\/z 286);\u202f\u304a\u3088\u3073\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\/\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3 (m\/z 150) Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306f<strong>\u540c\u91cd\u4f53\u3092\u5206\u96e2(Isobars To Resolve) <\/strong>(3E) \u3059\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u3092\u52b9\u679c\u7684\u306b\u8b58\u5225\u3001\u9752\u3044\u30dc\u30c3\u30af\u30b9\u5185\u306e\u767d\u3044\u30c1\u30a7\u30c3\u30af\u3067\u81ea\u52d5\u7684\u306b\u8b66\u544a\u3092\u8868\u793a\u3057\u307e\u3059\u3002\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u5206\u96e2\u306b\u95a2\u3057\u3066\u306f\u4e8b\u524d\u78ba\u8a8d\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u30e6\u30fc\u30b6\u30fc\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u904e\u7a0b\u3067\u540c\u91cd\u4f53\u3092\u898b\u843d\u3068\u3059\u5fc3\u914d\u304c\u306a\u304f\u3001\u5fc5\u8981\u3067\u3042\u308c\u3070\u5316\u5408\u7269\u306e\u9078\u629e\u3092\u89e3\u9664\u3059\u308b\u3060\u3051\u3067\u30ea\u30b9\u30c8\u304b\u3089\u9664\u5916\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u540c\u91cd\u4f53\u306e\u5206\u96e2\u3067\u306f\u3001\u5206\u96e2\u5ea6\u3060\u3051\u3067\u306a\u304f\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u95a2\u3059\u308b\u76ee\u6a19\u3092\u8003\u616e\u3057\u3064\u3064\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u3082\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u306b\u306a\u308a\u307e\u3059\u3002\u7279\u5b9a\u306e\u5316\u5408\u7269\u304c\u305d\u308c\u307b\u3069\u91cd\u8981\u3067\u306f\u306a\u3044\u5834\u5408\u3001\u307e\u305f\u306f\u7570\u306a\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3\u30a4\u30aa\u30f3\u306b\u3088\u3063\u3066\u533a\u5225\u3067\u304d\u308b\u5834\u5408\u3001\u5206\u96e2\u5ea6\u306e\u9078\u629e\u3092\u89e3\u9664\u3059\u308b\u3053\u3068\u3067\u5206\u6790\u6642\u9593\u304c\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002 (<strong>\u6ce8\u610f\uff1a<\/strong>\u7279\u5b9a\u306e\u5316\u5408\u7269\u3054\u3068\u306b\u9752\u3044\u30dc\u30c3\u30af\u30b9\u5185\u306e\u767d\u3044\u30c1\u30a7\u30c3\u30af\u30de\u30fc\u30af\u3092\u5916\u3057\u3066\u5206\u96e2\u3057\u305f\u3044\u540c\u91cd\u4f53\u306e\u9078\u629e\u3092\u89e3\u9664\u3059\u308b\u3053\u3068\u306f\u3001\u30e2\u30c7\u30eb\u306b\u542b\u3081\u308b\u305f\u3081\u306e\u5316\u5408\u7269\u306e\u9078\u629e\u3092\u89e3\u9664\u3059\u308b\u3053\u3068\u3068\u306f\u7570\u306a\u308a\u307e\u3059\u3002)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u5316\u5408\u7269<\/strong>\u30bf\u30d6\u3067\u306e\u6700\u5f8c\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u202f\u8a55\u4fa1\u3092\u884c\u3044\u305f\u3044<strong>\u56fa\u5b9a\u76f8(Phase)<\/strong>(3F) \u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u202f\u202f\u56fa\u5b9a\u76f8\u306e\u9078\u629e\u30ea\u30b9\u30c8\u306f\u3001Restek\u306e\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30b9\u30c8\u304c\u3059\u3067\u306b\u5316\u5408\u7269\u30e9\u30a4\u30d6\u30e9\u30ea\u3092\u53ce\u96c6\u3057\u3066\u691c\u8a3c\u3057\u305f\u3082\u306e\u306b\u9650\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u56fa\u5b9a\u76f8\u9078\u629e\u306e\u81ea\u7531\u5ea6\u306f\u9650\u5b9a\u3055\u308c\u307e\u3059\u304c\u3001\u3053\u308c\u306b\u3088\u308a\u3001\u7279\u5b9a\u306e\u5bfe\u8c61\u5206\u6790\u7269\u306b\u9069\u3057\u3066\u3044\u306a\u3044\u30ab\u30e9\u30e0\u304c\u9664\u5916\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u5316\u5408\u7269\u30ea\u30b9\u30c8\u3067\u306f\u3001C18\u3088\u308a\u3082\u5e83\u7bc4\u56f2\u306e\u5316\u5408\u7269\u3092\u5206\u96e2\u3067\u304d\u308bBiphenyl\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u307e\u3059\u3002Biphenyl\u76f8\u306f C18\u76f8\u3068\u6bd4\u8f03\u3057\u3066\u82b3\u9999\u65cf\u9078\u629e\u6027\u304c\u9ad8\u304f\u3001\u591a\u304f\u306e\u5834\u5408\u540c\u91cd\u4f53\u3092\u542b\u3080\u56f0\u96e3\u306a\u5206\u6790\u7269\u3092\u5206\u96e2\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001Biphenyl\u76f8\u304c\u6709\u3059\u308b\u3088\u308a\u5f37\u529b\u306a\u4fdd\u6301\u529b\u306b\u3088\u308a\u3001\u6eb6\u51fa\u306e\u65e9\u3044\u5316\u5408\u7269\u306b\u767a\u751f\u3057\u304c\u3061\u306a\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u7531\u6765\u3059\u308b\u30a4\u30aa\u30f3\u5316\u6291\u5236\u306e\u4f4e\u6e1b\u306b\u3082\u5f79\u7acb\u3061\u307e\u3059\u3002\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u5f8c\u3001<strong>\u30e2\u30c7\u30eb\u751f\u6210(Generate Model)<\/strong>\u30dc\u30bf\u30f3 (3G) \u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u3001\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u304c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc\u9818\u57df (3H) \u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30e2\u30c7\u30eb\u304c\u751f\u6210\u3055\u308c\u308b\u3068<strong>\u5316\u5408\u7269<\/strong>\u30bf\u30d6\u306e\u4e0b\u90e8\u306b\u8ffd\u52a0\u306e\u30e1\u30c3\u30bb\u30fc\u30b8\u304c\u3044\u304f\u3064\u304b\u8868\u793a\u3055\u308c\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u30e2\u30c7\u30eb\u306b\u95a2\u3059\u308b\u30b5\u30dd\u30fc\u30c8\u306b\u3064\u3044\u3066\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30fc\u30d3\u30b9\u3078\u76f4\u63a5\u30ea\u30af\u30a8\u30b9\u30c8\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u7279\u306b\u3001\u30ea\u30b9\u30c8\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u30e2\u30c7\u30eb\u306b\u8ffd\u52a0\u3067\u304d\u306a\u304b\u3063\u305f\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u306f\u30ea\u30af\u30a8\u30b9\u30c8\u3092\u304a\u9858\u3044\u3057\u307e\u3059\u3002\u4e0d\u8db3\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u306f\u3059\u3050\u306b\u306f\u5229\u7528\u3067\u304d\u307e\u305b\u3093\u304c\u3001\u5c06\u6765\u7684\u306bModeler\u3078\u306e\u8ffd\u52a0\u304c\u691c\u8a0e\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u521d\u671f\u30e2\u30c7\u30eb\u306e\u8a55\u4fa1<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306b\u5bfe\u3057\u3066Pro <em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u305f\u6700\u521d\u306e\u30e2\u30c7\u30eb\u5206\u96e2\u3092<strong>Figure 4<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002\u81ea\u52d5\u751f\u6210\u3055\u308c\u305f\u6761\u4ef6\u306b\u5bfe\u3057\u3066\u3001\u552f\u4e00\u884c\u3063\u305f\u5909\u66f4\u306fDwell Volume\u3092\u30c7\u30d5\u30a9\u30eb\u30c8\u306e0.25 mL\u304b\u30890.38 mL\u306b\u8abf\u6574\u3057\u305f\u3053\u3068\u3060\u3051\u3067\u3059\u3002Dwell Volume\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u306e\u8a18\u4e8b\u306e\u5f8c\u534a\u3067\u6700\u9069\u5316\u6761\u4ef6\u691c\u8a0e\u306e\u969b\u306b\u8ffd\u52a0\u3067\u8aac\u660e\u3092\u884c\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u5909\u66f4\u306f\u3001\u30e9\u30dc\u88c5\u7f6e\u306eDwell Volume\u3068\u5408\u308f\u305b\u3001\u30e2\u30c7\u30eb\u306e\u7cbe\u5ea6\u3092\u8a55\u4fa1\u3059\u308b\u76ee\u7684\u3067\u884c\u3044\u307e\u3057\u305f\u3002\u521d\u671f\u30e2\u30c7\u30eb\u3092\u8a55\u4fa1\u3057\u3001\u5b9f\u969b\u306b\u30e9\u30dc\u3067\u518d\u73fe\u5b9f\u9a13\u3092\u5b9f\u65bd\u3057\u305f\u5f8c\u306b\u3001\u3055\u3089\u306b\u6700\u9069\u5316\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> Pro\u202f\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u305f\u521d\u671f\u30e2\u30c7\u30eb (4A)\u3002\u3053\u306e\u30e2\u30c7\u30eb\u306f\u3001\u30e9\u30dc\u3067\u5b9f\u969b\u306b\u4f7f\u7528\u3059\u308b\u3053\u3068\u3082\u3001\u202f<strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9 (\u8d64\u3067\u56f2\u3093\u3060\u90e8\u5206)\u3068\u5165\u529b\u30d5\u30a3\u30fc\u30eb\u30c9\u3092\u901a\u3058\u3066\u30e6\u30fc\u30b6\u30fc\u304c\u3055\u3089\u306b\u8abf\u6574\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002 <strong>4A<\/strong>\u521d\u671f\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc (\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5316\u5408\u7269\u306e\u8a73\u7d30\u306f\u3001\u753b\u9762\u3092\u30b9\u30af\u30ed\u30fc\u30eb\u3059\u308b\u3068\u78ba\u8a8d\u53ef\u80fd) \u3001<strong>4B<\/strong>[\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316] \u30dc\u30bf\u30f3\u3001<strong>4C<\/strong>\u30e6\u30fc\u30b6\u30fc\u5165\u529b\u30d5\u30a3\u30fc\u30eb\u30c9\u3001<strong>4D<\/strong>\u540c\u91cd\u4f53\u9078\u629e\u30ea\u30b9\u30c8\u3001<strong>4E<\/strong>\u7d50\u679c\u30d5\u30a3\u30fc\u30eb\u30c9<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"704\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNAR3915-04-1024x704.jpg\" alt=\"\" class=\"wp-image-21435\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-04-1024x704.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-04-300x206.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-04-768x528.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-04-1536x1056.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-04.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u671f\u30e2\u30c7\u30eb\u306e\u5177\u4f53\u7684\u306a\u7d50\u679c (<strong>Figure 5<\/strong>) \u3092\u8a73\u3057\u304f\u898b\u308b\u3068\u3001Chromatogram Modeler\u304c\u30b7\u30f3\u30d7\u30eb\u306a\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3067 \u307b\u3068\u3093\u3069\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u3092\u9054\u6210\u3057\u3066\u304a\u308a\u3001\u304b\u3064\u5206\u6790\u6642\u9593\u3068\u3057\u3066\u306f7.4\u5206\u306e\u30e2\u30c7\u30eb\u3092\u751f\u6210\u3057\u305f\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u30e2\u30c7\u30eb\u306e\u4e0b\u306b\u3042\u308b\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u306e\u8868\u306b\u306f\u3001\u4fdd\u6301\u6642\u9593\u3001\u5206\u96e2\u5ea6\u3001\u30d4\u30fc\u30af\u5e45\u3001\u6eb6\u51fa %B\u3001\u30a4\u30aa\u30f3\u5316\u30e2\u30fc\u30c9\u3001\u4e00\u822c\u7684\u306a\u30e2\u30cb\u30bf\u30fc\u30a4\u30aa\u30f3\u306a\u3069\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306e\u8ffd\u52a0\u60c5\u5831\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u671f\u30e2\u30c7\u30eb\u3067\u306f\u3001\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\/\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u3068\u30b8\u30d2\u30c9\u30ed\u30b3\u30c7\u30a4\u30f3\/\u30ce\u30eb\u30aa\u30ad\u30b7\u30b3\u30c9\u30f3\/O-\u30c7\u30b9\u30e1\u30c1\u30eb-\u30b7\u30b9-\u30c8\u30e9\u30de\u30c9\u30fc\u30eb\/\u30b3\u30c7\u30a4\u30f3\u306e 2 \u3064\u306e\u30b0\u30eb\u30fc\u30d7\u306e\u5171\u6eb6\u51fa\u304c\u4e88\u6e2c\u3055\u308c\u307e\u3057\u305f\u3002\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u60c5\u5831\u304b\u3089\u3001\u6700\u521d\u306e\u30b0\u30eb\u30fc\u30d7\u306e\u5316\u5408\u7269 (\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\/\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3) \u306f\u30d7\u30ec\u30ab\u30fc\u30b5\u30a4\u30aa\u30f3\u3068\u30d7\u30ed\u30c0\u30af\u30c8\u30a4\u30aa\u30f3\u306e\u4e21\u65b9\u3092\u5171\u6709\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u6210\u5206\u3092\u500b\u5225\u306b\u5831\u544a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u7d50\u679c\u306e\u6b63\u78ba\u3055\u3092\u4fdd\u3064\u305f\u3081\u306b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u305f\u3060\u3057\u30012 \u756a\u76ee\u306e\u30b0\u30eb\u30fc\u30d7\u3067\u306f\u30014 \u3064\u306e\u5316\u5408\u7269\u3059\u3079\u3066\u304c\u7570\u306a\u308b\u30d5\u30e9\u30b0\u30e1\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3\u30d7\u30ed\u30c0\u30af\u30c8\u30a4\u30aa\u30f3\u3092\u6301\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u5171\u6eb6\u51fa\u304c\u8a8d\u3081\u3089\u308c\u305f\u3068\u3057\u3066\u3082MS\u306b\u3088\u3063\u3066\u533a\u5225\u3067\u304d\u307e\u3059\u3002\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u5171\u6eb6\u51fa\u306e\u7a0b\u5ea6\u3092\u3088\u308a\u9069\u5207\u306b\u8996\u899a\u5316\u3057\u305f\u3044\u5834\u5408\u306f\u3001<strong>\u9078\u629e\u53ef\u80fd\u306a\u540c\u91cd\u4f53(Available Isobars)<\/strong>\u30ea\u30b9\u30c8\u304b\u3089\u76ee\u7684\u306e\u540c\u91cd\u4f53\u30a4\u30aa\u30f3\u3092\u9078\u629e\u3057\u3066\u8868\u793a\u3057\u307e\u3059\u202f(<strong>Figure 6<\/strong>)\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5316\u5408\u7269\u60c5\u5831\u306b\u52a0\u3048\u3066\u3001Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306f\u3001\u4f5c\u6210\u3057\u305f\u5206\u6790\u6761\u4ef6\u304c\u3001\u4e00\u822c\u7684\u306aHPLC \u30b7\u30b9\u30c6\u30e0\u306e\u5727\u529b\u5236\u9650\u3092\u8d85\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3068\u3044\u3046\u6709\u7528\u306a\u8b66\u544a\u3082\u767a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30dc\u30a4\u30c9\u30bf\u30a4\u30e0 (T0) \u3082\u8868\u793a\u3055\u308c\u308b\u305f\u3081\u3001\u6eb6\u51fa\u306e\u65e9\u3044\u5316\u5408\u7269\u3068T0\u306e\u9593\u306b\u9069\u5207\u306a\u5206\u96e2\u304c\u4fdd\u3066\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3092\u8003\u616e\u3059\u308b\u3053\u3068\u3067\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> Pro\u202f<em>EZ<\/em>LC \u3067\u4f5c\u6210\u3057\u305f\u3001Restek Biphenyl\u30ab\u30e9\u30e0\u3067\u306e15\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u306e\u5206\u96e2\u30e2\u30c7\u30eb<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"893\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNAR3915-05-893x1024.jpg\" alt=\"\" class=\"wp-image-21441\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05-893x1024.jpg 893w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05-262x300.jpg 262w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05-768x881.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05-1340x1536.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05-1786x2048.jpg 1786w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-05.jpg 1800w\" sizes=\"auto, (max-width: 893px) 100vw, 893px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> \u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3092\u8996\u899a\u7684\u306b\u5f37\u8abf\u8868\u793a\u3067\u304d\u307e\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6 (<strong> [\u5206\u6790\u6761\u4ef6]<\/strong>\u30bf\u30d6\u3067\u8a2d\u5b9a\u53ef\u80fd) \u306b\u9054\u3057\u3066\u3044\u306a\u3044\u540c\u91cd\u4f53\u306f\u3001\u5171\u6eb6\u51fa\u306e\u7a0b\u5ea6\u306b\u5fdc\u3058\u3066\u8d64\u307e\u305f\u306f\u30aa\u30ec\u30f3\u30b8\u3067\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u9069\u5207\u306b\u5206\u96e2\u3055\u308c\u305f\u540c\u91cd\u4f53\u306f\u7dd1\u8272\u3067\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-06.jpg\" alt=\"figure-article-GNAR3915-06.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u3092\u78ba\u8a8d\u5f8c\u3001Pro&nbsp;<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u4eee\u60f3\u7684\u306b\u4f5c\u6210\u3057\u305f\u5206\u96e2\u304c\u3001\u3069\u306e\u7a0b\u5ea6\u6b63\u78ba\u306b\u518d\u73fe\u3067\u304d\u308b\u306e\u304b\u3001\u5b9f\u969b\u306b\u30e9\u30dc\u306e\u88c5\u7f6e\u3092\u7528\u3044\u3066\u518d\u73fe\u8a66\u9a13\u3092\u884c\u3044\u307e\u3057\u305f\u202f\u3002<strong>Figure 7<\/strong>\u306f\u3001Pro <em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u4f5c\u6210\u3057\u305f\u6761\u4ef6\u3092\u7528\u3044\u305f\u3001\u30e9\u30dc\u306eLC-MS\/MS \u306b\u3088\u308b\u518d\u73fe\u8a66\u9a13\u306e\u7d50\u679c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u5b9f\u969b\u306e\u30e9\u30dc\u3067\u306e\u518d\u73fe\u8a66\u9a13\u306b\u304a\u3044\u3066\u306f\u3001\u9023\u7d9a\u5206\u6790\u3092\u884c\u3046\u306b\u3042\u305f\u308a\u3001\u6ce8\u5165\u524d\u306e\u5e73\u8861\u5316\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5206\u6790\u30b5\u30a4\u30af\u30eb\u306b\u306f\u518d\u5e73\u8861\u5316\u30b9\u30c6\u30c3\u30d7\u304c\u8ffd\u52a0\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u751f\u6210\u3055\u308c\u305f\u7d50\u679c\u3068\u5b9f\u969b\u306e\u7d50\u679c\u3092\u6bd4\u8f03\u3059\u308b\u3068\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u304c\u540c\u3058\u9806\u5e8f\u3067\u540c\u69d8\u306e\u4fdd\u6301\u6642\u9593\u3067\u6eb6\u51fa\u3057\u307e\u3057\u305f\u3002\u5171\u6eb6\u51fa\u30d1\u30bf\u30fc\u30f3\u3082\u540c\u69d8\u3067\u3057\u305f\u304c\u3001\u4e88\u6e2c\u3055\u308c\u305f\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\/\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u306e\u5171\u6eb6\u51fa\u306f\u3001\u30e9\u30dc\u304c\u6240\u6709\u3059\u308bRaptor Biphenyl\u30ab\u30e9\u30e0\u3068\u88c5\u7f6e\u3092\u7528\u3044\u305f\u518d\u73fe\u8a66\u9a13\u3067\u306f\u5206\u96e2\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u30e2\u30c7\u30eb\u6bb5\u968e\u3067\u5171\u6eb6\u51fa\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u304c\u3001\u5b9f\u5206\u6790\u3067\u5206\u96e2\u3055\u308c\u308b\u30b1\u30fc\u30b9\u3092\u7d4c\u9a13\u3059\u308b\u3053\u3068\u3082\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u3053\u308c\u306f\u3001Pro\u202f\u202f<em>EZ<\/em>LC Chromatogram Modeler\u304c\u4fdd\u5b88\u7684\u304b\u3064\u5206\u96e2\u5ea6\u3092\u614e\u91cd\u306b\u898b\u7a4d\u3082\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> \u30e9\u30dc\u3067\u751f\u6210\u3055\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u306f\u3001Pro\u202f<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u4f5c\u6210\u3057\u305f\u30e2\u30c7\u30eb\u3068\u307b\u307c\u4e00\u81f4\u3057\u307e\u3057\u305f\u3002\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\/\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u3067\u4e88\u6e2c\u3055\u308c\u305f\u5171\u6eb6\u51fa\u306f\u30e9\u30dc\u518d\u73fe\u5b9f\u9a13\u3067\u306f\u5206\u96e2\u3055\u308c\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0687.png\" alt=\"EZLC Generated Model\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0687<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>EZLC<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0687.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u300c\u5206\u6790\u6761\u4ef6\u300d\u30bf\u30d6\u3067\u30e2\u30c7\u30eb\u3092\u6700\u9069\u5316\u3059\u308b<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pro <em>EZ<\/em>\u202fLC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u305f\u521d\u671f\u30e2\u30c7\u30eb\u306f\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u88c5\u7f6e\u3078\u306e\u30b9\u30e0\u30fc\u30ba\u306a\u79fb\u7ba1\u30fb\u5b9f\u88c5\u304c\u53ef\u80fd\u3067\u3001\u304b\u3064\u3001\u512a\u308c\u305f\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u3001<strong>Figure 4<\/strong>\u306b\u793a\u3059\u5206\u6790\u6761\u4ef6\u30bf\u30d6\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3092\u4f7f\u7528\u3057\u3001\u3055\u3089\u306b\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u202f\u202f\u6b21\u306e\u4f8b\u3067\u306f\u3001\u521d\u671f\u30e2\u30c7\u30eb\u3092\u6700\u9069\u5316\u3057\u3066\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3092\u8a66\u307f\u305f\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u3092\u6539\u826f\u3059\u308b\u6700\u3082\u901f\u3044\u65b9\u6cd5\u306f\u3001<strong>\u202f\u202f[\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316]\u202f(Optimize Gradient Slope)<\/strong>\u30dc\u30bf\u30f3 (4B) \u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u308c\u3092\u7e70\u308a\u8fd4\u3057\u5b9f\u884c\u3057\u3066\u3001\u73fe\u5728\u306e\u6761\u4ef6\u3092\u30d9\u30fc\u30b9\u306b\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u5909\u66f4\u3057\u3001\u5206\u96e2\u5ea6\u3068\u5206\u6790\u6642\u9593\u3092\u3055\u3089\u306b\u6539\u5584\u3067\u304d\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u3042\u308b\u3044\u306f\u3001\u5206\u6790\u8005\u306f\u3001\u30e6\u30fc\u30b6\u30fc\u5165\u529b\u30d5\u30a3\u30fc\u30eb\u30c9 (4C) \u306b\u3042\u308b\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3067\u3001\u3088\u308a\u9ad8\u5ea6\u306a\u30e1\u30bd\u30c3\u30c9\u6700\u9069\u5316\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u30e6\u30fc\u30b6\u30fc\u306f\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3001\u30b7\u30b9\u30c6\u30e0\u5bb9\u91cf \u3001\u6709\u6a5f\u6eb6\u5a92\u79fb\u52d5\u76f8\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30b0\u30e9\u30e0\u3001\u304a\u3088\u3073\u5206\u96e2\u5ea6\u3092\u5909\u66f4\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d5\u30a3\u30fc\u30eb\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u624b\u52d5\u3067\u5909\u66f4\u3059\u308b\u3068\u3001\u305d\u306e\u52b9\u679c\u3092\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc\u3068<strong>\u7d50\u679c(Result)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u306e\u4e21\u65b9\u3067\u5373\u5ea7\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059 (4E)\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u9069\u5316\u306e\u969b\u306f\u3001\u7279\u5b9a\u306e\u5206\u6790\u76ee\u6a19\u3068\u3001\u5404\u30e6\u30fc\u30b6\u30fc\u5165\u529b\u30bb\u30af\u30b7\u30e7\u30f3\u306e\u5909\u6570\u306b\u95a2\u3059\u308b\u4ee5\u4e0b\u306e\u60c5\u5831\u3092\u614e\u91cd\u306b\u8003\u616e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u52a0\u3048\u305f\u5909\u66f4\u304c\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u306e\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3082\u5206\u6790\u5bfe\u8c61\u7269\u306e\u5206\u96e2\u50be\u5411\u3092\u77e5\u308b\u3046\u3048\u3067\u3068\u3066\u3082\u91cd\u8981\u3068\u306a\u308a\u307e\u3059\u3002Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30e9\u30dc\u3067\u4f55\u65e5\u3082\u6642\u9593\u3092\u8cbb\u3084\u3059\u3053\u3068\u306a\u304f\u3001\u7c21\u5358\u304b\u3064\u8fc5\u901f\u306b\u3001\u30d9\u30b9\u30c8\u306a\u30ab\u30e9\u30e0\u9078\u629e\u3084\u3001\u5727\u529b\u3068\u3044\u3063\u305f\u4f7f\u7528\u88c5\u7f6e\u306e\u5236\u9650\u3092\u8003\u616e\u3057\u305f\u7d50\u679c\u3092\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u3067\u78ba\u8a8d\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30ab\u30e9\u30e0<br>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3059\u308b\u5834\u5408\u3001\u3088\u308a\u77ed\u304f\u5185\u5f84\u306e\u7d30\u3044\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u6eb6\u5a92\u7bc0\u7d04\u3001\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u304c\u671f\u5f85\u3067\u304d\u307e\u3059 (\u5206\u96e2\u8981\u4ef6\u304c\u6e80\u305f\u3055\u308c\u3066\u3044\u308b\u9650\u308a)\u3002\u3088\u308a\u9ad8\u3044\u5206\u96e2\u5ea6\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001\u5206\u6790\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u3068\u3044\u3046\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u3063\u305f\u3068\u3057\u3066\u3082\u3001\u3088\u308a\u9577\u3044\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3082\u8003\u616e\u3057\u305f\u307b\u3046\u304c\u3088\u3044\u3067\u3057\u3087\u3046\u3002\u305f\u3060\u3057\u3001Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306b\u3088\u3063\u3066\u63d0\u793a\u3055\u308c\u308b\u9078\u629e\u80a2\u306b\u306f\u3001\u5bfe\u8c61\u5206\u6790\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u308b\u30ab\u30e9\u30e0\u306e\u307f\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u9078\u629e\u53ef\u80fd\u306a\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u304c\u9650\u5b9a\u7684\u3067\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002Modeler\u306e\u7d50\u679c\u306f Restek\u30ab\u30e9\u30e0\u3067\u306e\u307f\u691c\u8a3c\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u6027\u80fd\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u30b7\u30ea\u30ab\u306e\u4ed5\u69d8\u3001\u7d50\u5408\u69d8\u5f0f\u3001\u5145\u586b\u30d7\u30ed\u30c8\u30b3\u30eb\u306a\u3069\u304c\u7570\u306a\u308b\u4ed6\u30e1\u30fc\u30ab\u30fc\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5834\u5408\u306b\u306f\u30e2\u30c7\u30eb\u306e\u518d\u73fe\u304c\u3067\u304d\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ea\u30b9\u30c8\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u306a\u3044\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u304c\u5fc5\u8981\u306a\u969b\u306f\u3001Restek\u30ab\u30e9\u30e0\u306e\u540c\u30b7\u30ea\u30fc\u30ba\u304b\u3089\u76ee\u7684\u306b\u5408\u81f4\u3057\u305f\u3082\u306e\u3092\u9078\u629e\u3044\u305f\u3060\u304f\u304b\u3001\u307e\u305f\u3001\u5f0a\u793e\u30c6\u30af\u30cb\u30ab\u30eb\u30b9\u30bf\u30c3\u30d5\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<br><br><\/li>\n\n\n\n<li>\u30dc\u30ea\u30e5\u30fc\u30e0\u52b9\u679c<br><strong>Dwell Volume<\/strong> \u3068<strong>\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf(Extra-Column Volume)<\/strong>\u306f\u3001\u305d\u308c\u305e\u308c\u4fdd\u6301\u6642\u9593\u3068\u30d4\u30fc\u30af\u5e45\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u88c5\u7f6e\u56fa\u6709\u306e\u5024\u3067\u3059\u3002Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306f\u3053\u308c\u3089\u306e\u30d5\u30a3\u30fc\u30eb\u30c9\u3067\u4e00\u822c\u7684\u306a\u30c7\u30d5\u30a9\u30eb\u30c8\u5024\u3092\u4f7f\u7528\u3057\u307e\u3059\u304c\u3001\u305d\u308c\u3089\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u88c5\u7f6e\u306e\u6b63\u78ba\u306a\u5024\u306b\u5909\u66f4\u3059\u308b\u3068\u3001\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u308b\u88c5\u7f6e\u306b\u5bfe\u3057\u3066\u3088\u308a\u6b63\u78ba\u306a\u30e2\u30c7\u30eb\u3092\u751f\u6210\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u5bb9\u91cf\u3092\u898b\u3064\u3051\u308b\u306b\u306f\u3001\u88c5\u7f6e\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3059\u308b\u304b\u3001\u88c5\u7f6e\u306e\u30e1\u30fc\u30ab\u30fc\u306b\u554f\u3044\u5408\u308f\u305b\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306e\u5bb9\u91cf\u304c\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3001\u307e\u305f\u3001\u304a\u4f7f\u3044\u306e\u88c5\u7f6e\u3067\u306e\u305d\u308c\u3089\u306e\u5bb9\u91cf\u3092\u6c7a\u5b9a\u3059\u308b\u65b9\u6cd5\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Pro\u202f<em>EZ<\/em>LC\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u306e<strong>\u30d8\u30eb\u30d7<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br><br><\/li>\n\n\n\n<li>\u79fb\u52d5\u76f8<br>\u79fb\u52d5\u76f8\u306e\u6709\u6a5f\u6eb6\u5a92\u3092\u9078\u629e\u3059\u308b\u3068\u304d\u306f\u3001\u6eb6\u5a92\u306e\u76f8\u5bfe\u7684\u306a\u30e6\u30fc\u30c8\u30ed\u30d4\u30c3\u30af\u5f37\u5ea6\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u4fdd\u6301\u3068\u9078\u629e\u6027\u306e\u4e21\u65b9\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3067\u3059\u3002\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb (\u975e\u30d7\u30ed\u30c8\u30f3\u6027\u6eb6\u5a92) \u306f\u30e1\u30bf\u30ce\u30fc\u30eb (\u30d7\u30ed\u30c8\u30f3\u6027\u6eb6\u5a92) \u3088\u308a\u3082\u6eb6\u51fa\u5f37\u5ea6\u304c\u9ad8\u3044\u305f\u3081\u3001\u4ed6\u306e\u3059\u3079\u3066\u304c\u540c\u3058\u6761\u4ef6\u306a\u3089\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3068\u5206\u6790\u7269\u306f\u3088\u308a\u65e9\u304f\u6eb6\u51fa\u3055\u308c\u307e\u3059\u3002\u7279\u306b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u5f71\u97ff\u6392\u9664\u3084Void Volume\u4ed8\u8fd1\u3067\u306e\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e\u6eb6\u51fa\u3068\u3044\u3063\u305f\u3001\u65e9\u671f\u6eb6\u51fa\u3078\u306e\u5bfe\u7b56\u3068\u3057\u3066\u4fdd\u6301\u3092\u6539\u5584\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u304c\u3088\u308a\u826f\u3044\u9078\u629e\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u9006\u306b\u4fdd\u6301\u3092\u5f31\u3081\u305f\u3044\u5834\u5408\u306f\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u91cf\u3092\u5897\u3084\u3059\u304b\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6eb6\u5a92\u9078\u629e\u306e\u5909\u66f4\u306f\u3001\u5168\u4f53\u7684\u306a\u4fdd\u6301\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u5316\u5408\u7269\u306e\u7279\u6027\u306b\u3088\u3063\u3066\u306f(\u4f8b:\u202f\u79fb\u52d5\u76f8\u306b\u3088\u3063\u3066\u30d7\u30ed\u30c8\u30f3\u5316\u72b6\u614b\u304c\u5909\u308f\u308b\u3088\u3046\u306a\u30b1\u30fc\u30b9)\u3001\u76f8\u5bfe\u7684\u306a\u4fdd\u6301 (\u9078\u629e\u6027) \u3084\u6eb6\u51fa\u9806\u5e8f\u306b\u3082\u5909\u5316\u3092\u4e0e\u3048\u308b\u3067\u3057\u3087\u3046\u3002Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306b\u3088\u3063\u3066\u63d0\u793a\u3055\u308c\u308b\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306e\u5834\u5408\u3068\u540c\u69d8\u3001\u79fb\u52d5\u76f8\u306e\u9078\u629e\u306f\u3001Restek\u306e\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30b9\u30c8\u306b\u3088\u3063\u3066\u30c6\u30b9\u30c8\u3055\u308c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u6790\u7269\u306b\u5bfe\u3057\u3066\u9069\u5207\u306b\u6a5f\u80fd\u3059\u308b\u3068\u5224\u65ad\u3055\u308c\u305f\u6709\u6a5f\u6eb6\u5a92\u306e\u307f\u3067\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br><br>\u79fb\u52d5\u76f8\u306e\u6709\u6a5f\u6eb6\u5a92\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306b\u52a0\u3048\u3066\u3001Pro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u3067\u306f\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6 (\u6700\u5927 60 \u00b0C) \u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u6e29\u5ea6\u306e\u4e0a\u6607\u306f\u3001\u6eb6\u5a92\u7c98\u5ea6\u306e\u4f4e\u4e0b\u3055\u305b\u308b\u305f\u3081\u3001\u305d\u308c\u306b\u4f34\u3044<strong>\u80cc\u5727(back pressure)<\/strong>\u306e\u4f4e\u4e0b\u304c\u89b3\u5bdf\u3055\u308c\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u4e00\u65b9\u3001\u6e29\u5ea6\u306e\u4f4e\u4e0b\u306f\u305d\u306e\u9006\u306e\u73fe\u8c61\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u9078\u629e\u3059\u308b\u3068\u304d\u306f\u3001\u30ab\u30e9\u30e0\u3068\u88c5\u7f6e\u306e\u6e29\u5ea6\u5236\u9650\u306a\u3089\u3073\u306b\u80cc\u5727\u4e0a\u9650\u306b\u5e38\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br><br><\/li>\n\n\n\n<li>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6<br>Pro\u202f<em>EZ<\/em>LC<strong>\u202f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6(Gradient Program)<\/strong>\u3067\u306f<strong>\u3001<\/strong>\u202f\u30c7\u30d5\u30a9\u30eb\u30c8\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u304c 1.50 \u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30e6\u30fc\u30b6\u30fc\u306e\u30cb\u30fc\u30ba\u306b\u5408\u308f\u305b\u3066\u5909\u66f4\u3067\u304d\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u540c\u91cd\u4f53\u5316\u5408\u7269\u3067\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u304c\u6e80\u305f\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3001Modeler\u306f<strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6(Target Resolution)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u202f\u306e\u6a2a\u306b\u202f\u8b66\u544a\u8a18\u53f7 (&nbsp;<img loading=\"lazy\" decoding=\"async\" width=\"20\" height=\"20\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-warning-sign.jpg\" alt=\"figure-article-GNAR3915-warning-sign.jpg\" title=\"-\">&nbsp;) \u3092\u8868\u793a\u3057\u307e\u3059\u3002\u521d\u671f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306f\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u3088\u3063\u3066\u81ea\u52d5\u7684\u306b\u63d0\u4f9b\u3055\u308c\u307e\u3059\u304c\u3001&nbsp;<strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316(Optimize Gradient Slope)<\/strong>\u30dc\u30bf\u30f3\u3092\u5229\u7528\u3059\u308b\u304b\u3001\u624b\u52d5\u3067\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u3067\u5909\u66f4\u304c\u3067\u304d\u307e\u3059\u202f\u3002\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u8ffd\u52a0\u3059\u308b\u306b\u306f<strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30b9\u30c6\u30c3\u30d7\u6570(# of Gradient Steps)<\/strong>\u306e\u5024\u3092\u5909\u66f4\u3057\u307e\u3059\u3002<br><br>Modeler\u306f\u81ea\u52d5\u7684\u306b\u65b0\u3057\u3044\u30b9\u30c6\u30c3\u30d7\u3092\u633f\u5165\u3057\u3001\u5143\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u50be\u304d\u3092\u7dad\u6301\u3059\u308b\u5024\u3092\u5272\u308a\u5f53\u3066\u307e\u3059\u304c\u3001\u5024\u306f\u8abf\u6574\u53ef\u80fd\u306a\u305f\u3081\u3001\u81ea\u7531\u306b\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306e\u50be\u304d\u3092\u5909\u66f4\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u958b\u59cb\u70b9\u3068\u7d42\u4e86\u70b9\u306b\u30db\u30fc\u30eb\u30c9\u6761\u4ef6\u3082\u8ffd\u52a0\u3067\u304d\u307e\u3059\u3002\u9023\u7d9a\u5206\u6790\u306e\u969b\u306b\u5fc5\u8981\u306a\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30bb\u30c3\u30c8\u306b\u5f79\u7acb\u3064\u3088\u3046\u306b\u3001\u518d\u5e73\u8861\u306e\u6761\u4ef6\u3092\u6700\u5f8c\u306b\u8ffd\u52a0\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306f\u5b9f\u969b\u306e\u30e9\u30dc\u5206\u6790\u3067\u306f\u5fc5\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u304c\u3001\u30e2\u30c7\u30ea\u30f3\u30b0\u6bb5\u968e\u3067\u306f\u518d\u5e73\u8861\u5316\u306e\u914d\u616e\u306f\u4e0d\u8981\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u306b\u5909\u66f4\u304c\u52a0\u3048\u3089\u308c\u308b\u3068\u3001Chromatogram Modeler\u306f\u5024\u3092\u81ea\u52d5\u7684\u306b\u66f4\u65b0\u3059\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u751f\u6210\u3059\u308b\u5834\u5408\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u307e\u305a\u3001\u6700\u3082\u8fd1\u63a5\u3057\u3066\u6eb6\u51fa\u3057\u3066\u3044\u308b\u540c\u91cd\u4f53\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u3092\u6e80\u305f\u3059\u3053\u3068\u3092\u8a66\u307f\u3001\u6b21\u306b\u3001\u5171\u6eb6\u51fa\u3059\u308b\u540c\u91cd\u5408\u4f53\u5316\u5408\u7269\u304c\u53ef\u80fd\u306a\u9650\u308a\u5c11\u306a\u304f\u306a\u308b\u3088\u3046\u306b\u3057\u306a\u304c\u3089\u3082\u3001\u6700\u901f\u306e\u5206\u6790\u6642\u9593\u3092\u63d0\u4f9b\u3059\u308b\u8a2d\u8a08\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u5ea6\u3001\u4e71\u7528\u85ac\u7269\u306e\u4f8b\u306b\u623b\u308a\u307e\u3059\u3002\u6b21\u306b\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u305f\u3081\u306b\u521d\u671f\u30e2\u30c7\u30eb\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u306b\u3057\u307e\u3059\u3002\u5206\u6790\u3092\u9ad8\u901f\u5316\u3059\u308b\u305f\u3081\u3001\u6709\u6a5f\u6eb6\u5a92\u79fb\u52d5\u76f8\u3092\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306b\u5909\u66f4\u3057\u3001\u5206\u6790\u521d\u671f\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u6642\u9593\u3092\u8a2d\u5b9a\u30012 \u3064\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30b9\u30c6\u30c3\u30d7\u3092\u8ffd\u52a0\u3057\u3066%B \u5024\u3092\u5909\u66f4\u3001\u3055\u3089\u306b\u6d41\u901f\u3092\u4e0a\u3052\u307e\u3057\u305f\u3002\u524d\u8ff0\u3057\u305f\u3088\u3046\u306b\u3001\u30e9\u30dc\u3067\u4f7f\u7528\u3059\u308b\u88c5\u7f6e\u306b\u5408\u308f\u305b\u3066\u3001Dwell Volume\u306f\u3059\u3067\u306b 0.38 mL \u306b\u5909\u66f4\u3055\u308c\u3066\u3044\u307e\u3059\u3002<strong>Figure 8<\/strong>\u306e\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001\u3053\u3053\u3067\u6700\u9069\u5316\u3057\u305f\u6761\u4ef6\u306f\u3001\u6700\u521d\u306e\u5206\u6790\u6761\u4ef6 (7.4 \u5206) \u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3066\u3044\u307e\u3059 (3 \u5206)\u3002\u5206\u6790\u3092\u534a\u5206\u4ee5\u4e0b\u307e\u3067\u77ed\u7e2e\u3067\u304d\u305f\u305f\u3081\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3059\u308b\u4e00\u65b9\u3001\u5171\u6eb6\u51fa\u304c\u4e88\u6e2c\u3055\u308c\u308b\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u3068\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\u3067\u306f\u5206\u96e2\u5ea6\u306e\u4f4e\u4e0b\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> \u30e6\u30fc\u30b6\u30fc\u304c\u6700\u9069\u5316\u3057\u305f Pro\u202f\u202f<em>EZ<\/em>LC \u30e2\u30c7\u30eb\u306b\u3088\u308b\u3001Restek Biphenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f15\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u306e\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5316<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3915-08.jpg\" alt=\"figure-article-GNAR3915-08.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Chromatogram Modeler\u306e\u7cbe\u5ea6\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306e\u6700\u7d42\u30b9\u30c6\u30c3\u30d7\u3068\u3057\u3066\u3001\u901f\u5ea6\u304c\u6700\u9069\u5316\u3055\u308c\u305f\u30e2\u30c7\u30eb\u6761\u4ef6\u3092\u7528\u3044\u3066\u30e9\u30dc\u3067\u306e\u518d\u73fe\u5b9f\u9a13\u3092\u884c\u3044\u307e\u3057\u305f (<strong>Figure 9<\/strong>)\u3002\u3053\u3053\u3067\u3082\u3001Pro\u202f\u202f<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u6eb6\u51fa\u9806\u5e8f\u3092\u6b63\u78ba\u306b\u4e88\u6e2c\u3057\u3001\u4fdd\u6301\u6642\u9593\u3092\u53b3\u5bc6\u306b\u4e88\u6e2c\u3057\u307e\u3057\u305f\u3002\u30e2\u30c7\u30eb\u3067\u306f\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u3068\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\u306f\u5171\u6eb6\u51fa\u304c\u4e88\u6e2c\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u518d\u73fe\u5b9f\u9a13\u3067\u3082\u5171\u6eb6\u51fa\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002\u30d5\u30a7\u30f3\u30c6\u30eb\u30df\u30f3\u3068\u30e1\u30bf\u30f3\u30d5\u30a7\u30bf\u30df\u30f3\u306f\u540c\u3058\u30d7\u30ed\u30c0\u30af\u30c8\u30a4\u30aa\u30f3\u3092\u5171\u6709\u3059\u308b\u540c\u91cd\u4f53\u5316\u5408\u7269\u3067\u3042\u308b\u305f\u3081\u3001MS\u306b\u3088\u308b\u533a\u5225\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30e6\u30fc\u30b6\u30fc\u306f\u3053\u308c\u3089\u306e\u7279\u5b9a\u306e\u5316\u5408\u7269\u3092\u5206\u6790\u306b\u304a\u3051\u308b\u30ea\u30b9\u30af\u3092\u8003\u616e\u3057\u305f\u3046\u3048\u3067\u3001\u901f\u5ea6\u3068\u5206\u96e2\u3001\u3069\u3061\u3089\u304c\u512a\u5148\u3068\u306a\u308b\u306e\u304b\u3092\u81ea\u5206\u3067\u5224\u65ad\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> \u30e9\u30dc\u306e\u518d\u73fe\u5b9f\u9a13\u3067\u5f97\u3089\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7d50\u679c\u306f\u3001\u901f\u5ea6\u304c\u6700\u9069\u5316\u3055\u308c\u305f Pro\u202f\u202f<em>EZ<\/em>LC\u30e2\u30c7\u30eb\u3068\u307b\u307c\u4e00\u81f4\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0685.png\" alt=\"EZLC Optimized Model\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0685<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>EZLC<\/li><li>Model<\/li><li>Optimized<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0685.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Pro&nbsp;<em>EZ<\/em>LC \u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306a\u3089\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u304b\u3064\u30b7\u30f3\u30d7\u30eb\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u306b\u793a\u3059\u3088\u3046\u306b\u3001Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3092\u52b9\u679c\u7684\u304b\u3064\u52b9\u7387\u7684\u306b\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Restek\u306ePro\u202f<em>EZ<\/em>LC Chromatogram Modeler\u306f\u7121\u6599\u306a\u4e0a\u306b\u3001\u4f55\u3089\u304b\u306e\u30c7\u30fc\u30bf\u3092\u30e6\u30fc\u30b6\u30fc\u304c\u6e96\u5099\u3059\u308b\u5fc5\u8981\u3082\u3042\u308a\u307e\u305b\u3093\u3002\u5b9f\u969b\u306e\u5206\u96e2\u3092\u6570\u79d2\u3067\u6b63\u78ba\u306b\u4e88\u6e2c\u3059\u308b\u305f\u3081\u3001\u5f93\u6765\u306e\u30e9\u30dc\u30d9\u30fc\u30b9\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u6bd4\u3079\u3066\u307b\u3093\u306e\u308f\u305a\u304b\u306a\u6642\u9593\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3067\u304d\u307e\u3059\u3002 Pro\u202f<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u30b7\u30f3\u30d7\u30eb\u306b\u3057\u3001\u6642\u9593\u3068\u8cbb\u7528\u306e\u7bc0\u7d04\u3092\u5927\u5e45\u306b\u6539\u5584\u3057\u307e\u3059\u3002\u7279\u306b\u3001\u5b9f\u969b\u306e\u4f5c\u696d\u8005\u306b\u3068\u3063\u3066\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u5909\u66f4\u3057\u3066\u52b9\u679c\u3092\u5373\u5ea7\u306b\u78ba\u8a8d\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308b\u305f\u3081\u3001\u4f5c\u696d\u306e\u52b9\u7387\u5316\u3082\u671f\u5f85\u3067\u304d\u308b\u3067\u3057\u3087\u3046\u3002Pro\u202f<em>EZ<\/em>LC\u3067\u4f5c\u6210\u3057\u305f\u521d\u671f\u30e2\u30c7\u30eb\u3092\u30e9\u30dc\u3067\u5b9f\u88c5\u3001\u307e\u305f\u306f\u5206\u96e2\u5ea6\u3084\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u95a2\u3057\u3066\u3055\u3089\u306b\u6700\u9069\u5316\u3092\u5b9f\u884c\u3059\u308b\u304b\u3069\u3046\u304b\u306b\u95a2\u308f\u3089\u305a\u3001\u3053\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u306f\u3001\u3088\u308a\u8fc5\u901f\u3067\u30b7\u30f3\u30d7\u30eb\u306a\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u57fa\u76e4\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u3053\u306e\u7121\u6599\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u6b21\u4e16\u4ee3\u578b\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u6249\u3092\u3001\u3069\u306a\u305f\u3067\u3082\u958b\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Restek\u304c\u63d0\u4f9b\u3059\u308bPro\u202f<em>EZ<\/em>LC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u30e6\u30fc\u30b6\u30fc\u306e\u307f\u306a\u3055\u307e\u306e\u7814\u7a76\u3084\u30d3\u30b8\u30cd\u30b9\u3092\u3001\u65b0\u305f\u306a\u8a66\u307f\u3067\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u305f\u3081\u306e\u6700\u9069\u306a\u30d1\u30fc\u30c8\u30ca\u30fc\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309212\">                                \u30ab\u30bf\u30ed\u30b0No. 9309212                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 1.8 \u00b5m, 100 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309212\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304212\">                                \u30ab\u30bf\u30ed\u30b0No. 9304212                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 1.8 \u00b5m, 100 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304212\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u672c\u8a18\u4e8b\u3067\u306f\u3001Pro EZLC\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e2\u30c7\u30ea\u30f3\u30b0\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u5229\u7528\u3057\u305fLC-MS\/MS\u6cd5\u306e\u958b\u767a\u30d7\u30ed\u30bb\u30b9\u3092\u7d39\u4ecb\u3002\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u7d50\u679c\u3068\u5b9f\u969b\u30e9\u30dc\u3067\u53d6\u5f97\u3057\u305f\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u304a\u3051\u308b\u6642\u9593\u306e\u7bc0\u7d04\u3068\u624b\u9806\u306e\u7c21\u7d20\u5316\u3092\u5b9f\u8a3c\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7153,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2343],"ppma_author":[2814],"class_list":["post-43699","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR3915-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43699"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43699\/revisions"}],"predecessor-version":[{"id":69175,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43699\/revisions\/69175"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7153"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43699"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43699"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43699"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43699"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43699"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43699"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}