{"id":43718,"date":"2025-03-24T00:00:00","date_gmt":"2025-03-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/raptor-c18-lc-columns-brochure\/"},"modified":"2026-09-25T18:07:08","modified_gmt":"2026-09-25T18:07:08","slug":"raptor-c18-lc-columns-brochure","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles\/gnbr2246\/raptor-c18-lc-columns-brochure","title":{"rendered":"Raptor C18: Raptor Speed, Efficiency, and Ruggedness\u2014in C18"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">With Raptor LC columns, Restek chemists became the first to combine the speed of 2.7 and 5 \u03bcm superficially porous particles (also known as SPP or \u201ccore-shell\u201d particles) with the resolution of highly selective USLC technology, improving separations and speeding up analysis times with standard HPLC instruments. Raptor then evolved to bring that same improved speed, efficiency, and selectivity to UHPLC analyses by offering 1.8 \u03bcm particle columns. Learn more about Raptor LC columns at <a href=\"articles\/raptor-lc-columns&quot;\">www.restek.com\/raptor<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Even though every LC lab has a cache of C18s, not all C18s are created equal. Because the chemistry tends to be similar, the silica support that carries this ubiquitous octadecylsilane phase becomes vitally important. When you need a general-purpose LC column, don\u2019t just grab any C18. Choose the speed, efficiency, and long-lasting ruggedness of the Raptor C18 SPP LC column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The traditional end-capped Raptor C18 offers the highest hydrophobic retention of any Raptor phase, and it is compatible with a wide range of mobile phases from moderately acidic to neutral (pH 2\u20138). Whether for food safety, environmental, or bioanalytical analyses, this phase offers consistently excellent data quality in less time across myriad reversed-phase applications, matrices, and compound classes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Column Description:<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-top is-layout-flow wp-block-column-is-layout-flow\"><style>.kb-image43718_623f7f-44.kb-image-is-ratio-size, .kb-image43718_623f7f-44 .kb-image-is-ratio-size{max-width:232px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image43718_623f7f-44.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image43718_623f7f-44 .kb-image-is-ratio-size{align-self:unset;}.kb-image43718_623f7f-44 figure{max-width:232px;}.kb-image43718_623f7f-44 .image-is-svg, .kb-image43718_623f7f-44 .image-is-svg img{width:100%;}.kb-image43718_623f7f-44 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43718_623f7f-44\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"459\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-459x1024.jpg\" alt=\"\" class=\"kb-img wp-image-61678\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-459x1024.jpg 459w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-135x300.jpg 135w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-768x1712.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-689x1536.jpg 689w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-919x2048.jpg 919w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnbr2246b-01-1-scaled.jpg 1149w\" sizes=\"auto, (max-width: 459px) 100vw, 459px\" \/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"wp-block-heading\">Stationary Phase Category:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">C18, octadecylsilane (L1)<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Ligand Type:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">End-capped C18<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Particle:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">1.8 \u03bcm, 2.7 \u03bcm, or 5 \u03bcm superficially porous particle (SPP or \u201ccore-shell\u201d particle) silica<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Pore Size:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">90 \u00c5<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Surface Area:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">125 m<sup>2<\/sup>\/g (1.8 \u03bcm),<br>130 m<sup>2<\/sup>\/g (2.7 \u03bcm),<br>or 100 m<sup>2<\/sup>\/g (5 \u03bcm)<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"wp-block-heading\">Recommended Usage:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">pH Range: 2.0\u20138.0<br>Maximum Temperature: 80 \u00b0C<br>Maximum Pressure: 1034 bar\/15,000 psi* (1.8 \u03bcm),<br>600 bar\/8700 psi (2.7 \u03bcm); 400 bar\/5800 psi (5 \u03bcm)<br><em>* For maximum lifetime, recommended maximum pressure for 1.8 \u03bcm particles is&nbsp;<\/em><em>830 bar\/12,000 psi.<\/em><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Properties:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Compatible with moderately acidic to neutral&nbsp;mobile phases (pH 2\u20138).<\/li>\n\n\n\n<li>Excellent data quality in food, environmental, bioanalytical,&nbsp;and other applications.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Switch to a C18 when:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>You need a general-purpose column for&nbsp;reversed-phase chromatography.<\/li>\n\n\n\n<li>You need to increase retention of hydrophobic compounds.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Column Interaction Profile:<\/h2>\n\n\n<style>.kb-image43718_3a1756-70.kb-image-is-ratio-size, .kb-image43718_3a1756-70 .kb-image-is-ratio-size{max-width:273px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image43718_3a1756-70.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image43718_3a1756-70 .kb-image-is-ratio-size{align-self:unset;}.kb-image43718_3a1756-70{max-width:273px;}.image-is-svg.kb-image43718_3a1756-70{-webkit-flex:0 1 100%;flex:0 1 100%;}.image-is-svg.kb-image43718_3a1756-70 img{width:100%;}.kb-image43718_3a1756-70 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43718_3a1756-70 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"432\" height=\"510\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnbr2246b-01.jpg\" alt=\"\" class=\"kb-img wp-image-12250\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnbr2246b-01.jpg 432w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnbr2246b-01-254x300.jpg 254w\" sizes=\"auto, (max-width: 432px) 100vw, 432px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Defining Solute Interactions:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dispersion<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Solute Retention Profile:<\/h2>\n\n\n<style>.kb-image43718_7e8b67-d5 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43718_7e8b67-d5 size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"253\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1-768x253.jpg\" alt=\"\" class=\"kb-img wp-image-61684\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1-768x253.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1-300x99.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1-1024x337.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1-1536x505.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnbr2246b-01-1.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Target Analyte Structures:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hydrocarbons<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Target Analyte Functionalities:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hydrophobic compounds<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Raptor C18 Performance: Speed, Efficiency, and Ruggedness in Action<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor C18 columns provide outstanding dependability and data quality with high efficiency and peak symmetry, and they are built to exacting specifications that make your columns exceptionally consistent and improve their lifetime. To lower costs and improve profitability, you need columns to last longer, data to be reproducible, and existing HPLC instrumentation to run faster. Get there with the only general-purpose C18 that gives you <em>Selectivity Accelerated<\/em>.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Comparing 50 mm x 2.1 mm sub-2 \u03bcm C18 columns, Raptor columns maintain reliable performance past 1000 injections, consistently matching or beating the competition.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-1\" style=\"color:#68bd45\">Expect consistently high performance over 1000 injections<\/h3>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-figure-gnbr2246b-03.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0Raptor columns&#8217; stringent quality control (QC) specifications guarantee outstanding peak shape, even with active compounds, for superior data quality.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-2\" style=\"color:#68bd45\">Outstanding peak shapes for top-notch data<\/h3>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0557.png\" alt=\"Acidic Probes on Raptor\u2122 C18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0557<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Tolunitrile\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/104-85-8\/p-Tolunitrile\" target=\"_blank\" rel=\"noopener\">p-Tolunitrile<\/a><\/td><td class=\"oth\">1.681<\/td><td class=\"oth\">0.6<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Butylbenzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20651-71-2\/4-Butylbenzoic acid\" target=\"_blank\" rel=\"noopener\">4-Butylbenzoic acid<\/a><\/td><td class=\"oth\">3.088<\/td><td class=\"oth\">0.8<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,4-Dimethylanisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4685-47-6\/3,4-Dimethylanisole\" target=\"_blank\" rel=\"noopener\">3,4-Dimethylanisole<\/a><\/td><td class=\"oth\">4.096<\/td><td class=\"oth\">1.0<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-42-3\/p-Xylene\" target=\"_blank\" rel=\"noopener\">p-Xylene<\/a><\/td><td class=\"oth\">5.827<\/td><td class=\"oth\">0.4<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mefenamic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61-68-7\/Mefenamic acid\" target=\"_blank\" rel=\"noopener\">Mefenamic acid<\/a><\/td><td class=\"oth\">6.539<\/td><td class=\"oth\">0.6<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor\u2122 C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A1E\" rel=\"noopener\">cat.# 9304A1E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile:water:phosphoric acid (65:34:1)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.05% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.05% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>55<\/td><td>45<\/td><\/tr><tr><td>8.00<\/td><td>0.8<\/td><td>55<\/td><td>45<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>HPLC @ 220 nm<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Cell Temp:<\/th><td>40 \u00b0C<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A1E<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0557.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0Lot-to-lot reproducibility is the key to keeping your productivity high and budget low. You can expect the same exceptional performance from every Raptor C18 column you purchase.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-3\" style=\"color:#68bd45\">Lot-to-lot reproducibility for fast, reliable results every time<\/h3>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ph0532.png\" alt=\"Chromatographic Overlay of 3 Silica Lots of Raptor\u2122 C18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_PH0532<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-76-3\/Methylparaben\" target=\"_blank\" rel=\"noopener\">Methylparaben<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-47-8\/Ethylparaben\" target=\"_blank\" rel=\"noopener\">Ethylparaben<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-13-3\/Propylparaben\" target=\"_blank\" rel=\"noopener\">Propylparaben<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-26-8\/Butylparaben\" target=\"_blank\" rel=\"noopener\">Butylparaben<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor\u2122 C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304512\" rel=\"noopener\">cat.# 9304512<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>5 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 \u00b5g\/mL in water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>1.0<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>2.00<\/td><td>1.0<\/td><td>20<\/td><td>80<\/td><\/tr><tr><td>2.01<\/td><td>1.0<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>3.50<\/td><td>1.0<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>PDA @ 254 nm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304512<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>cosmetic<\/li><li>preservative<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ph0532.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Boost Your Productivity with Raptor C18 LC Columns<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When developing an assay, it is important to consider how productive your method will be. Because superficially porous, or \u201ccore-shell,\u201d particles are well known for very high efficiency with minimal backpressure, they are ideal for decreasing analysis time (Figure 4). With its general-purpose applicability and SPP core-shell particles, the Raptor C18 column lets you quickly develop faster methods, thereby boosting your productivity.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0SPP particles, like those in the Raptor C18 column, are one important step towards total method optimization.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ph0543.png\" alt=\"Speed Comparison of Raptor C18 vs. FPP C18 for Raptor C18 Sales Sheet Figure 4\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_PH0543<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">Raptor C18 t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 50px\">Fully Porous C18 t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-76-3\/Methylparaben\" target=\"_blank\" rel=\"noopener\">Methylparaben<\/a><\/td><td class=\"oth\">0.73<\/td><td class=\"oth\">2.90<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-47-8\/Ethylparaben\" target=\"_blank\" rel=\"noopener\">Ethylparaben<\/a><\/td><td class=\"oth\">1.01<\/td><td class=\"oth\">3.77<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-13-3\/Propylparaben\" target=\"_blank\" rel=\"noopener\">Propylparaben<\/a><\/td><td class=\"oth\">1.27<\/td><td class=\"oth\">5.34<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butylparaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-26-8\/Butylparaben\" target=\"_blank\" rel=\"noopener\">Butylparaben<\/a><\/td><td class=\"oth\">1.50<\/td><td class=\"oth\">8.03<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes <\/td><\/tr><tr><td><\/td><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Parabens<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 \u00b5g\/mL<\/td><\/tr><td><\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><tr><th class=\"sub conditions_header\" scope=\"row\">Flow:<\/th><td>1.0 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Raptor C18: PDA @ 254 nm; FPP C18: UV\/Vis @ 254 nm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><b>Raptor C18<\/b><br \/>Column: Raptor C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304512\" rel=\"noopener\">cat.# 9304512<\/a>); 100 mm x 2.1 mm ID, 5 \u00b5m<br \/>Temp.: 40 \u00b0C<br \/>Sample diluent: water<br \/>Inj. vol.: 1 \u00b5L <br \/>Mobile phase: A: water, B: acetonitrile <br \/>Gradient (%B): 0.00 min (20% B); 2.00 min (80% B); 2.01 min (20% B); 3.50 min (20% B)<br \/><br \/><br \/><b>Fully Porous Particle (FPP) C18<\/b><br \/>Column: traditional fully porous C18; 150 mm x 4.6 mm ID, 5 \u00b5m<br \/>Temp.: ambient<br \/>Sample diluent: methanol<br \/>Inj. vol.: 5 \u00b5L <br \/>Mobile phase: 0.1% acetic acid in water:acetonitrile (50:50)<br \/><br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304512<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ph0543.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong>\u00a0Raptor C18s offer exceptional peak symmetry and efficiency for high sensitivity\u2014making them ideal for high-throughput LC-MS\/MS.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0557.png\" alt=\"Flavonols on Raptor C18 by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FF0557<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Rutin<\/td><td class=\"oth\">1.04<\/td><td class=\"oth\">611.5<\/td><td class=\"oth\">303.3<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">Quercitrin<\/td><td class=\"oth\">1.19<\/td><td class=\"oth\">449.4<\/td><td class=\"oth\">303.3<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myricetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/529-44-2\/Myricetin\" target=\"_blank\" rel=\"noopener\">Myricetin<\/a><\/td><td class=\"oth\">1.26<\/td><td class=\"oth\">319.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fisetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-48-3\/Fisetin\" target=\"_blank\" rel=\"noopener\">Fisetin<\/a><\/td><td class=\"oth\">1.27<\/td><td class=\"oth\">287.3<\/td><td class=\"oth\">137.3<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/480-16-0\/Morin\" target=\"_blank\" rel=\"noopener\">Morin<\/a><\/td><td class=\"oth\">1.36<\/td><td class=\"oth\">303.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quercetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-39-5\/Quercetin\" target=\"_blank\" rel=\"noopener\">Quercetin<\/a><\/td><td class=\"oth\">1.48<\/td><td class=\"oth\">303.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kaempferol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/520-18-3\/Kaempferol\" target=\"_blank\" rel=\"noopener\">Kaempferol<\/a><\/td><td class=\"oth\">1.68<\/td><td class=\"oth\">287.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isorhamnetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/480-19-3\/Isorhamnetin\" target=\"_blank\" rel=\"noopener\">Isorhamnetin<\/a><\/td><td class=\"oth\">1.72<\/td><td class=\"oth\">317.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Rhamnetin<\/td><td class=\"oth\">1.91<\/td><td class=\"oth\">317.3<\/td><td class=\"oth\">123.3<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Galangin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/548-83-4\/Galangin\" target=\"_blank\" rel=\"noopener\">Galangin<\/a><\/td><td class=\"oth\">2.15<\/td><td class=\"oth\">271.3<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304552\" rel=\"noopener\">cat.# 9304552<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>5 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>90:10 (water:acetonitrile)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.1% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>2.40<\/td><td>0.5<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>2.41<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>3.50<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304552<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>C18<\/li><li>flavonol<\/li><li>raptor<\/li><li>raptor C18<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0557.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Your Go-To LC Column for Fast and Dependable Analyses on Any Instrument<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">C18 columns are often a method developer\u2019s first choice, not only for their trusted performance but also for their effectiveness with many types of compound and instrument. The Raptor C18 was designed to build on that foundation, offering usability, peak symmetry, efficiency, and dependability\u2014with the unmatched reproducibility, speed, and reliability of a Raptor SPP LC column. Whether you are doing environmental, food safety, or bioanalytical work (Figures 5 and 6), you will finish your work faster if you choose the right column the first time. For general-purpose applications, the Raptor C18 is your best first choice.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong>\u00a0Get the data quality and short analysis times you need with Raptor C18 columns, as shown here with perfluorinated compounds (PFCs).<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.png\" alt=\"Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 \u03bcm)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0540<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">0.90<\/td><td class=\"oth\">5<\/td><td class=\"oth\">213.07<\/td><td class=\"oth\">169.07<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentanoic acid (PFPeA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-90-3\/Perfluoropentanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentanoic acid (PFPeA)<\/a><\/td><td class=\"oth\">1.83<\/td><td class=\"oth\">5<\/td><td class=\"oth\">263.10<\/td><td class=\"oth\">219.11<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutane sulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutane sulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">2.09<\/td><td class=\"oth\">5<\/td><td class=\"oth\">299.10<\/td><td class=\"oth\">79.99<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/757124-72-4\/1H, 1H, 2H, 2H-perfluorohexane sulfonic acid\" target=\"_blank\" rel=\"noopener\">1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)<\/a><\/td><td class=\"oth\">2.63<\/td><td class=\"oth\">5<\/td><td class=\"oth\">327.10<\/td><td class=\"oth\">307.08<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">2.70<\/td><td class=\"oth\">5<\/td><td class=\"oth\">313.10<\/td><td class=\"oth\">269.12<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentane sulfonic acid (PFPeS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-91-4\/Perfluoropentane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentane sulfonic acid (PFPeS)<\/a><\/td><td class=\"oth\">2.84<\/td><td class=\"oth\">5<\/td><td class=\"oth\">349.10<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptanoic acid (PFHpA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-85-9\/Perfluoroheptanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptanoic acid (PFHpA)<\/a><\/td><td class=\"oth\">3.33<\/td><td class=\"oth\">5<\/td><td class=\"oth\">363.16<\/td><td class=\"oth\">319.09<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexane sulfonic acid (PFHxS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexane sulfonic acid (PFHxS)<\/a><\/td><td class=\"oth\">3.39<\/td><td class=\"oth\">5<\/td><td class=\"oth\">399.13<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Perfluorohexyl ethanoic acid (FHEA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53826-12-3\/2-Perfluorohexyl ethanoic acid\" target=\"_blank\" rel=\"noopener\">2-Perfluorohexyl ethanoic acid (FHEA)<\/a><\/td><td class=\"oth\">3.46<\/td><td class=\"oth\">250<\/td><td class=\"oth\">377.13<\/td><td class=\"oth\">293.07<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27619-97-2\/1H, 1H, 2H, 2H-perfluorooctane sulfonic acid\" target=\"_blank\" rel=\"noopener\">1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)<\/a><\/td><td class=\"oth\">3.78<\/td><td class=\"oth\">5<\/td><td class=\"oth\">427.17<\/td><td class=\"oth\">407.18<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">3.81<\/td><td class=\"oth\">5<\/td><td class=\"oth\">413.16<\/td><td class=\"oth\">369.10<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptane sulfonic acid (PFHpS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-92-8\/Perfluoroheptane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptane sulfonic acid (PFHpS)<\/a><\/td><td class=\"oth\">3.84<\/td><td class=\"oth\">5<\/td><td class=\"oth\">449.17<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanoic acid (PFNA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-95-1\/Perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanoic acid (PFNA)<\/a><\/td><td class=\"oth\">4.19<\/td><td class=\"oth\">5<\/td><td class=\"oth\">463.16<\/td><td class=\"oth\">419.19<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctane sulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctane sulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">4.21<\/td><td class=\"oth\">5<\/td><td class=\"oth\">499.17<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Perfluorooctyl ethanoic acid (FOEA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27854-31-5\/2-Perfluorooctyl ethanoic acid\" target=\"_blank\" rel=\"noopener\">2-Perfluorooctyl ethanoic acid (FOEA)<\/a><\/td><td class=\"oth\">4.31<\/td><td class=\"oth\">250<\/td><td class=\"oth\">477.17<\/td><td class=\"oth\">393.15<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39108-34-4\/1H, 1H, 2H, 2H-perfluorodecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)<\/a><\/td><td class=\"oth\">4.51<\/td><td class=\"oth\">5<\/td><td class=\"oth\">527.17<\/td><td class=\"oth\">507.16<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanoic acid (PFDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-76-2\/Perfluorodecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanoic acid (PFDA)<\/a><\/td><td class=\"oth\">4.52<\/td><td class=\"oth\">5<\/td><td class=\"oth\">513.17<\/td><td class=\"oth\">469.16<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononane sulfonic acid (PFNS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68259-12-1\/Perfluorononane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononane sulfonic acid (PFNS)<\/a><\/td><td class=\"oth\">4.53<\/td><td class=\"oth\">5<\/td><td class=\"oth\">549.17<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-methyl perfluorooctane sulfonamidoacetic acid (N-MeFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2355-31-9\/N-methyl perfluorooctane sulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-methyl perfluorooctane sulfonamidoacetic acid (N-MeFOSAA)<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">5<\/td><td class=\"oth\">570.20<\/td><td class=\"oth\">419.17<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecane sulfonic acid (PFDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-77-3\/Perfluorodecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecane sulfonic acid (PFDS)<\/a><\/td><td class=\"oth\">4.79<\/td><td class=\"oth\">5<\/td><td class=\"oth\">599.17<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-ethyl perfluorooctane sulfonamidoacetic acid (N-EtFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2991-50-6\/N-ethyl perfluorooctane sulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-ethyl perfluorooctane sulfonamidoacetic acid (N-EtFOSAA)<\/a><\/td><td class=\"oth\">4.79<\/td><td class=\"oth\">5<\/td><td class=\"oth\">584.20<\/td><td class=\"oth\">419.18<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\">Perfluorooctane sulfonamide (FOSA)<\/td><td class=\"oth\">4.79<\/td><td class=\"oth\">5<\/td><td class=\"oth\">498.17<\/td><td class=\"oth\">77.97<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecanoic acid (PFUnA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2058-94-8\/Perfluoroundecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecanoic acid (PFUnA)<\/a><\/td><td class=\"oth\">4.80<\/td><td class=\"oth\">5<\/td><td class=\"oth\">563.23<\/td><td class=\"oth\">519.24<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Perfluorodecyl ethanoic acid (FDEA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53826-13-4\/2-Perfluorodecyl ethanoic acid\" target=\"_blank\" rel=\"noopener\">2-Perfluorodecyl ethanoic acid (FDEA)<\/a><\/td><td class=\"oth\">4.91<\/td><td class=\"oth\">250<\/td><td class=\"oth\">577.23<\/td><td class=\"oth\">493.18<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanoic acid (PFDoA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-55-1\/Perfluorododecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanoic acid (PFDoA)<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">5<\/td><td class=\"oth\">613.23<\/td><td class=\"oth\">569.19<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1H, 1H, 2H, 2H-perfluorododecane sulfonic acid (10:2 FTS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120226-60-0\/1H, 1H, 2H, 2H-perfluorododecane sulfonic acid\" target=\"_blank\" rel=\"noopener\">1H, 1H, 2H, 2H-perfluorododecane sulfonic acid (10:2 FTS)<\/a><\/td><td class=\"oth\">5.05<\/td><td class=\"oth\">5<\/td><td class=\"oth\">627.23<\/td><td class=\"oth\">607.20<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecanoic acid (PFTrDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72629-94-8\/Perfluorotridecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecanoic acid (PFTrDA)<\/a><\/td><td class=\"oth\">5.25<\/td><td class=\"oth\">5<\/td><td class=\"oth\">663.23<\/td><td class=\"oth\">619.21<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\">N-methyl perfluorooctane sulfonamide (N-MeFOSA)<\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">5<\/td><td class=\"oth\">512.17<\/td><td class=\"oth\">169.07<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\">N-methyl perfluorooctane sulfonamidoethanol (N-MeFOSE)<\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">50<\/td><td class=\"oth\">616.27<\/td><td class=\"oth\">59.11<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotetradecanoic acid (PFTeDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/376-06-7\/Perfluorotetradecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotetradecanoic acid (PFTeDA)<\/a><\/td><td class=\"oth\">5.44<\/td><td class=\"oth\">5<\/td><td class=\"oth\">713.23<\/td><td class=\"oth\">669.23<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\">N-ethyl perfluorooctane sulfonamide (N-EtFOSA)<\/td><td class=\"oth\">5.47<\/td><td class=\"oth\">5<\/td><td class=\"oth\">526.23<\/td><td class=\"oth\">169.06<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\">N-ethyl perfluorooctane sulfonamidoethanol (N-EtFOSE)<\/td><td class=\"oth\">5.47<\/td><td class=\"oth\">50<\/td><td class=\"oth\">630.33<\/td><td class=\"oth\">59.11<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexadecanoic acid (PFHxDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67905-19-5\/Perfluorohexadecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexadecanoic acid (PFHxDA)<\/a><\/td><td class=\"oth\">5.74<\/td><td class=\"oth\">5<\/td><td class=\"oth\">813.30<\/td><td class=\"oth\">769.28<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctadecanoic acid (PFODA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16517-11-6\/Perfluorooctadecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctadecanoic acid (PFODA)<\/a><\/td><td class=\"oth\">5.98<\/td><td class=\"oth\">5<\/td><td class=\"oth\">913.30<\/td><td class=\"oth\">869.32<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304252\" rel=\"noopener\">cat.# 9304252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>1.8 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>80:20 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>5-250 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>5 mM Ammonium acetate in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>6.00<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.50<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.51<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>8.00<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304252<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>PFC<\/li><li>PFOA<\/li><li>PFOS<\/li><li>fluorotelomer<\/li><li>perfluorinated compound<\/li><li>perfluoroalkyl<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0540.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">The Perfect Complement to High-Throughput Mass Spec<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Fast LC-MS\/MS screens with their exacting retention time windows place severe demands on your LC column. The Raptor C18 can easily and dependably handle mass spec analysis of closely related compounds like macrolide antibiotics, which are widely used in human and veterinary medicine (Figure 7). Because it\u2019s a Raptor LC column, this C18 provides the reproducibility and consistent retention required for precise MRM analyses.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong>\u00a0Confidently analyze closely eluting compounds, like macrolide antibiotics in this bioanalytical analysis, by LC-MS\/MS.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0600.png\" alt=\"Macrolide Antibiotics on Raptor C18 by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0600<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spiramycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/8025-81-8\/Spiramycin\" target=\"_blank\" rel=\"noopener\">Spiramycin<\/a><\/td><td class=\"oth\">1.32<\/td><td class=\"oth\">844.21<\/td><td class=\"oth\">174.28<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azithromycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117772-70-0\/Azithromycin\" target=\"_blank\" rel=\"noopener\">Azithromycin<\/a><\/td><td class=\"oth\">1.33<\/td><td class=\"oth\">750.14<\/td><td class=\"oth\">591.83<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">Dirithromycin<\/td><td class=\"oth\">1.52<\/td><td class=\"oth\">836.26<\/td><td class=\"oth\">158.23<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tilmicosin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108050-54-0\/Tilmicosin\" target=\"_blank\" rel=\"noopener\">Tilmicosin<\/a><\/td><td class=\"oth\">1.58<\/td><td class=\"oth\">870.23<\/td><td class=\"oth\">174.29<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Erythromycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/114-07-8\/Erythromycin\" target=\"_blank\" rel=\"noopener\">Erythromycin<\/a><\/td><td class=\"oth\">1.87<\/td><td class=\"oth\">735.09<\/td><td class=\"oth\">158.23<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tylosin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1401-69-0\/Tylosin\" target=\"_blank\" rel=\"noopener\">Tylosin<\/a><\/td><td class=\"oth\">1.98<\/td><td class=\"oth\">917.26<\/td><td class=\"oth\">174.28<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clarithromycin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/81103-11-9\/Clarithromycin\" target=\"_blank\" rel=\"noopener\">Clarithromycin<\/a><\/td><td class=\"oth\">2.22<\/td><td class=\"oth\">749.11<\/td><td class=\"oth\">158.22<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Roxithromycin<\/td><td class=\"oth\">2.26<\/td><td class=\"oth\">838.21<\/td><td class=\"oth\">158.23<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Josamycin<\/td><td class=\"oth\">2.40<\/td><td class=\"oth\">829.15<\/td><td class=\"oth\">109.18<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304512\" rel=\"noopener\">cat.# 9304512<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>5 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water:acetonitrile (50:50)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.1% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>3.00<\/td><td>0.4<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>3.01<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>4.50<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304512<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Raptor<\/li><li>antibiotics<\/li><li>macrolide<\/li><li>raptor C18<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0600.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Improve Resolution on Your Current Methods<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To quickly improve your data quality, add a Raptor C18 SPP column to your existing C18 methods. As exemplified in Figure 8 with EPA method TO-11A, which determines toxic compounds in ambient air, the Raptor C18 offers better peak separation than a traditional fully porous C18.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> Make a good method even better with improved resolution by switching your traditional fully porous C18 for a Raptor C18 column.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0587.png\" alt=\"Resolution Comparison of Raptor C18 vs. FPP C18 for Raptor C18 Sales Sheet Figure 8\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0587<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">Raptor C18 t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 50px\">Fully Porous C18 t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Formaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-00-0\/Formaldehyde\" target=\"_blank\" rel=\"noopener\">Formaldehyde<\/a><\/td><td class=\"oth\">2.814<\/td><td class=\"oth\">1.954<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-07-0\/Acetaldehyde\" target=\"_blank\" rel=\"noopener\">Acetaldehyde<\/a><\/td><td class=\"oth\">3.551<\/td><td class=\"oth\">2.376<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrolein\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107-02-8\/Acrolein\" target=\"_blank\" rel=\"noopener\">Acrolein<\/a><\/td><td class=\"oth\">4.678<\/td><td class=\"oth\">2.884<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-64-1\/Acetone\" target=\"_blank\" rel=\"noopener\">Acetone<\/a><\/td><td class=\"oth\">4.877<\/td><td class=\"oth\">2.987<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propionaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-38-6\/Propionaldehyde\" target=\"_blank\" rel=\"noopener\">Propionaldehyde<\/a><\/td><td class=\"oth\">5.078<\/td><td class=\"oth\">3.190<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Crotonaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4170-30-3\/Crotonaldehyde\" target=\"_blank\" rel=\"noopener\">Crotonaldehyde<\/a><\/td><td class=\"oth\">6.361<\/td><td class=\"oth\">3.777<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butyraldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-72-8\/Butyraldehyde\" target=\"_blank\" rel=\"noopener\">Butyraldehyde<\/a><\/td><td class=\"oth\">6.818<\/td><td class=\"oth\">4.273<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">Raptor C18 t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 50px\">Fully Porous C18 t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-52-7\/Benzaldehyde\" target=\"_blank\" rel=\"noopener\">Benzaldehyde<\/a><\/td><td class=\"oth\">7.884<\/td><td class=\"oth\">4.653<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isovaleraldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/590-86-3\/Isovaleraldehyde\" target=\"_blank\" rel=\"noopener\">Isovaleraldehyde<\/a><\/td><td class=\"oth\">8.276<\/td><td class=\"oth\">5.572<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Valeraldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-62-3\/Valeraldehyde\" target=\"_blank\" rel=\"noopener\">Valeraldehyde<\/a><\/td><td class=\"oth\">8.653<\/td><td class=\"oth\">5.919<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Tolualdehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/529-20-4\/o-Tolualdehyde\" target=\"_blank\" rel=\"noopener\">o-Tolualdehyde<\/a><\/td><td class=\"oth\">9.502<\/td><td class=\"oth\">6.242<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Tolualdehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/620-23-5\/m-Tolualdehyde\" target=\"_blank\" rel=\"noopener\">m-Tolualdehyde<\/a><\/td><td class=\"oth\">9.667<\/td><td class=\"oth\">6.454<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Tolualdehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/104-87-0\/p-Tolualdehyde\" target=\"_blank\" rel=\"noopener\">p-Tolualdehyde<\/a><\/td><td class=\"oth\">9.825<\/td><td class=\"oth\">6.634<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexanal\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66-25-1\/Hexanal\" target=\"_blank\" rel=\"noopener\">Hexanal<\/a><\/td><td class=\"oth\">10.287<\/td><td class=\"oth\">8.450<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,5-Dimethylbenzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5779-94-2\/2,5-Dimethylbenzaldehyde\" target=\"_blank\" rel=\"noopener\">2,5-Dimethylbenzaldehyde<\/a><\/td><td class=\"oth\">11.064<\/td><td class=\"oth\">8.715<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes<\/td><\/tr><tr><td><\/td><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Aldehyde-ketone-DNPH TO-11A calibration mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31808\" rel=\"noopener\">cat.# 31808<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>15 \u00b5g\/mL<\/td><\/tr><td><\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><tr><th class=\"sub conditions_header\" scope=\"row\">Flow:<\/th><td>0.8-1.5 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Raptor C18: UV\/Vis @ 365, 4.8 nm; FPP C18: UV\/Vis @ 365, 1 nm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><b>Raptor C18<\/b><br \/>Column: Raptor C18 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A65\" rel=\"noopener\">cat.# 9304A65<\/a>); 150 mm x 4.6 mm ID, 2.7 \u00b5m<br \/>Temp.: 30 \u00b0C<br \/>Inj. vol.: 2 \u00b5L<br \/>Mobile phase: A: water, B: methanol:acetonitrile (650:50)*<br \/>Gradient (%B): 0.00 min (70% B); 5.00 min (75% B); 11.00 min (90% B); 11.01 min (100% B); 12.00 min (100% B); 12.01 min (70% B); 14.00 min (70% B)<br \/>Flow: 0.8 mL\/min<br \/>Notes: *Mobile phase B was prepared by combining 650 mL methanol and 50 mL acetonitrile.<br \/><br \/><b>Fully Porous Particle (FPP) C18<\/b><br \/>Column: Fully porous C18; 150 mm x 4.6 mm ID, 5 \u00b5m<br \/>Temp.: 25 \u00b0C<br \/>Inj. vol.: 10 \u00b5L<br \/>Mobile phase: water:acetonitrile (30:70)<br \/>Flow: 1.5 mL\/min<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31808<\/li><li>9304A65<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0587.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"background-color:#e4f7fa\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-4\" style=\"color:#02366d\">Want even better performance when analyzing mycotoxins and other metal-sensitive compounds?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more at&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"123\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png\" alt=\"\" class=\"wp-image-29764\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02-300x92.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A1E\">                                \u30ab\u30bf\u30ed\u30b0No. 9304A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A1E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304512\">                                \u30ab\u30bf\u30ed\u30b0No. 9304512                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 5 \u00b5m, 100 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304512\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304552\">                                \u30ab\u30bf\u30ed\u30b0No. 9304552                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304552\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304252\">                                \u30ab\u30bf\u30ed\u30b0No. 9304252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 1.8 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304252\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A65\">                                \u30ab\u30bf\u30ed\u30b0No. 9304A65                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 150 x 4.6 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A65\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25937\">                                \u30ab\u30bf\u30ed\u30b0No. 25937                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Hand-Tight Fitting (Nut w\/Ferrule)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25937\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                \u30ab\u30bf\u30ed\u30b0No. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0253\">                                \u30ab\u30bf\u30ed\u30b0No. 9304A0253                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 3.0 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0253\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Every LC lab has a cache of C18s, but every C18 is not created equal. When you need a general-purpose LC column, don\u2019t just grab any C18. Choose the speed, efficiency, and long-lasting ruggedness of the Raptor C18.<\/p>\n","protected":false},"author":11,"featured_media":7231,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7,7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2391,2373],"resource-technique":[2299,2301,2302],"ppma_author":[414],"class_list":["post-43718","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","product-library-lc-columns","product-library-liquid-chromatography-products","resource-technique-liquid-chromatography","resource-technique-mass-spectrometry-ms","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"},{"value":7,"label":"Articles"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2301,"label":"Mass Spectrometry (MS)"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNBR2246-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0},{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43718"}],"version-history":[{"count":17,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43718\/revisions"}],"predecessor-version":[{"id":94863,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43718\/revisions\/94863"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7231"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43718"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43718"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43718"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43718"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43718"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43718"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43718"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43718"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}