{"id":43739,"date":"2020-10-19T14:30:00","date_gmt":"2020-10-19T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/handy-septum-size-chart\/"},"modified":"2025-11-12T18:25:08","modified_gmt":"2025-11-12T18:25:08","slug":"handy-septum-size-chart","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles\/gnot3406\/handy-septum-size-chart","title":{"rendered":"Handy Septum Size Chart"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Instrument<\/strong><\/th><th><strong>Septum Diameter<\/strong><\/th><\/tr><\/thead><tbody><tr><td colspan=\"2\"><strong>Agilent<\/strong><\/td><\/tr><tr><td>5880A, 5890, 6850,&nbsp;6890, 7890, PTV<\/td><td>11 mm<\/td><\/tr><tr><td>5700, 5880<\/td><td>9.5\/10 mm<\/td><\/tr><tr><td>On-Column Injection<\/td><td>5 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Bruker\/Varian&nbsp;<\/strong><em>(Injector Type)<\/em><\/td><\/tr><tr><td>Packed Column<\/td><td>9.5\/10 mm<\/td><\/tr><tr><td>1078\/1079<\/td><td>10\/11 mm<\/td><\/tr><tr><td>1177<\/td><td>9 mm<\/td><\/tr><tr><td>1075\/1077<\/td><td>11 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Finnigan (TMQ)<\/strong><\/td><\/tr><tr><td>GC 9001<\/td><td>9.5 mm<\/td><\/tr><tr><td>GCQ<\/td><td>9.5 mm<\/td><\/tr><tr><td>QCQ<\/td><td>9.5 mm<\/td><\/tr><tr><td>TRACE 2000<\/td><td>9.5 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Gow-Mac<\/strong><\/td><\/tr><tr><td>6890 Series<\/td><td>11 mm<\/td><\/tr><tr><td>All Other Models<\/td><td>9.5 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>PerkinElmer<\/strong><\/td><\/tr><tr><td>Sigma Series<\/td><td>11 mm<\/td><\/tr><tr><td>900, 990<\/td><td>11 mm<\/td><\/tr><tr><td>8000 Series<\/td><td>11 mm<\/td><\/tr><tr><td>Auto SYS, Auto SYS XL<\/td><td>11 mm<\/td><\/tr><tr><td>Clarus 590\/690<\/td><td>11 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Pye\/Unicam<\/strong><\/td><\/tr><tr><td>All Models<\/td><td>7 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Shimadzu<\/strong><\/td><\/tr><tr><td>All Models<\/td><td>Plug<\/td><\/tr><tr><td colspan=\"2\"><strong>SRI<\/strong><\/td><\/tr><tr><td>GCs With Heated Inlets<\/td><td>9.5 mm<\/td><\/tr><tr><td>All Other Models<\/td><td>Plug<\/td><\/tr><tr><td colspan=\"2\"><strong>Thermo Scientific<\/strong><\/td><\/tr><tr><td>TRACE 1300\/1310, 1600\/1610 Series<\/td><td>11 mm<\/td><\/tr><tr><td>TRACE Ultra GC<\/td><td>17 mm<\/td><\/tr><tr><td>FOCUS GC<\/td><td>17 mm<\/td><\/tr><tr><td>GCQ w\/TRACE, PTV<\/td><td>12.7 mm<\/td><\/tr><tr><td>8000 Series<\/td><td>17 mm<\/td><\/tr><tr><td colspan=\"2\"><strong>Tracor<\/strong><\/td><\/tr><tr><td>540<\/td><td>11.5 mm<\/td><\/tr><tr><td>550, 560<\/td><td>9.5 mm<\/td><\/tr><tr><td>220, 222<\/td><td>12.7 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Restek septa are packaged in ultra-clean blister packs.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Tips for Handling Septa<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">All septa, regardless of composition, puncturability, or resistance to thermal degradation will fail if they are mishandled. Overtightening a septum nut invariably will reduce septum lifetime by increasing coring\/splitting. All septa contain volatile materials (e.g., phthalates) that are released when the septum is heated (septum bleed). Because most GCs are equipped with a septum purge, septum bleed generally will disappear within 30 minutes after installing a new septum and exposing it to normal injector temperatures. All Restek septa are preconditioned and are ready to use without delay\u2014order your Restek septa today at&nbsp;<a href=\"https:\/\/www.restek.com\/c\/1219\" target=\"_blank\" rel=\"noopener\">www.restek.com\/septa<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>What size septa do you need for maintaining your GC? This cross-reference chart is broken down by instrument manufacturer and model to give you a quick answer.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[2372,2386],"resource-technique":[2294],"ppma_author":[414],"class_list":["post-43739","post","type-post","status-publish","format-standard","hentry","category-articles","resource-type-selection-guides","product-library-gas-chromatography-products","product-library-inlet-supplies","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":567,"label":"Selection Guides"}],"product-library":[{"value":2372,"label":"Gas Chromatography Products"},{"value":2386,"label":"Inlet Supplies"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":7,"category_count":506,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43739"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43739\/revisions"}],"predecessor-version":[{"id":63181,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43739\/revisions\/63181"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43739"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43739"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43739"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43739"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43739"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43739"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}