{"id":43748,"date":"2020-10-20T00:00:00","date_gmt":"2020-10-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/instrument-reference-for-4-0-ml-wisp-48-style-vials\/"},"modified":"2026-08-11T15:21:45","modified_gmt":"2026-08-11T15:21:45","slug":"instrument-reference-for-4-0-ml-wisp-48-style-vials","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles\/gnot3413\/instrument-reference-for-4-0-ml-wisp-48-style-vials","title":{"rendered":"Instrument Reference for 4.0mL WISP 48 Style Vials"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">4.0mL<br>Screw-Thread Step<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"368\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-01-368x1024.jpg\" alt=\"\" class=\"wp-image-30076\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-01-368x1024.jpg 368w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-01-108x300.jpg 108w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-01.jpg 420w\" sizes=\"auto, (max-width: 368px) 100vw, 368px\" \/><figcaption class=\"wp-element-caption\">cat.# <br>24654, 24655,&nbsp;24656, 24657<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">4.0mL Clear<br>Crimp-Top<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"373\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-02-373x1024.jpg\" alt=\"\" class=\"wp-image-24304\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-02-373x1024.jpg 373w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-02-109x300.jpg 109w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3413-02.jpg 432w\" sizes=\"auto, (max-width: 373px) 100vw, 373px\" \/><figcaption class=\"wp-element-caption\">cat.#<br>24658, 24659<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The following instruments are compatible with 4.0mL WISP 48 style vials. For further information or questions, please contact your Restek sales representative or technical service.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Manufacturer<\/strong><\/th><th><strong>Instrument\/Model #<\/strong><\/th><\/tr><tr><td>Bruker<\/td><td>LC 51<\/td><\/tr><tr><td>Hitachi<\/td><td>L-7200, L7250<\/td><\/tr><tr><td>Phillips<\/td><td>LC-XP<\/td><\/tr><tr><td>Shimadzu<\/td><td>AOC-14\/1400, AOC-17, SIL-2AS<\/td><\/tr><tr><td>TosoHaas<\/td><td>TSK-6080, AS-8010, AS-8020<\/td><\/tr><tr><td>Unicam<\/td><td>LC-XP<\/td><\/tr><tr><td>Waters<\/td><td>48-pos. M700, 710, 717+<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Understand which instruments are compatible with 4.0 mL WISP 48 style vials.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2375,2405],"resource-technique":[],"ppma_author":[414],"class_list":["post-43748","post","type-post","status-publish","format-standard","hentry","category-articles","product-library-sample-preparation-products","product-library-vials-accessories"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"},{"value":2405,"label":"Vials &amp; Accessories"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":7,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43748"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43748\/revisions"}],"predecessor-version":[{"id":79142,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43748\/revisions\/79142"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43748"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43748"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43748"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43748"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43748"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43748"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43748"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43748"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}