{"id":43753,"date":"2020-10-21T00:00:00","date_gmt":"2020-10-21T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/thermal-desorption-tubes-vs-canister-sampling-japan\/"},"modified":"2026-06-10T00:25:50","modified_gmt":"2026-06-10T00:25:50","slug":"thermal-desorption-tubes-vs-canister-sampling-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3419-ja\/thermal-desorption-tubes-vs-canister-sampling-japan","title":{"rendered":"\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6 vs \u30ad\u30e3\u30cb\u30b9\u30bf\u3000\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u306f\u3069\u3061\u3089\u304c\u6700\u9069\uff1f"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b&nbsp; &nbsp;&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u3069\u306eVOC\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u6280\u8853\u304c\u3042\u306a\u305f\u306e\u5206\u6790\u306b\u3068\u3063\u3066\u6700\u9069\u304b\uff1f\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u3002\u00a0 \u00a0<br>\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u306f\u3001VOC\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u7528\u306e\u30ad\u30e3\u30cb\u30b9\u30bf\u306b\u5bfe\u3059\u308b\u88dc\u5b8c\u7684\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3067\u3059\u3002\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u3068\u30ad\u30e3\u30cb\u30b9\u30bf\u306b\u306f\u305d\u308c\u305e\u308c\u5229\u70b9\u3068\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u3069\u3061\u3089\u306e\u88c5\u7f6e\u304c\u3001\u3042\u306a\u305f\u304c\u3053\u308c\u304b\u3089\u884c\u304a\u3046\u3068\u3057\u3066\u3044\u308b\u5206\u6790\u306e\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u74b0\u5883\u3084\u5206\u6790\u80fd\u529b\u306b\u9069\u5408\u3057\u3066\u3044\u308b\u304b\u3001\u307e\u305a\u8a55\u4fa1\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3067\u3057\u3087\u3046\u3002\u4ee5\u4e0b\u306b\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u3068\u30ad\u30e3\u30cb\u30b9\u30bf\u306e\u985e\u4f3c\u70b9\u3068\u76f8\u9055\u70b9\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3069\u3061\u3089\u306e\u88c5\u7f6e\u3092\u4f7f\u3046\u304b\u3092\u6c7a\u3081\u308b\u969b\u306b\u4fbf\u5229\u306a\u6bd4\u8f03\u8868\u3092\u305c\u3072\u3054\u6d3b\u7528\u4e0b\u3055\u3044\uff01\u00a0\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u3068\u30ad\u30e3\u30cb\u30b9\u30bf\u306e\u985e\u4f3c\u70b9\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u518d\u5229\u7528\u53ef\u80fd\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30c7\u30d0\u30a4\u30b9\u3067\u3042\u308b\u3053\u3068<\/li>\n\n\n\n<li>\u88fd\u54c1\u5bff\u547d\u304c\u9577\u3044\u3053\u3068<\/li>\n\n\n\n<li>\u9577\u671f\u9593\u306b\u308f\u305f\u3063\u3066\u30b5\u30f3\u30d7\u30eb\u306e\u5b89\u5b9a\u6027\u3092\u78ba\u4fdd\u3067\u304d\u308b\u3053\u3068<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u5148\u7acb\u3063\u3066\u5fc5\u8981\u306a\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u3092\u4f7f\u7528\u3057\u305f\u5206\u6790\u306e\u4fe1\u983c\u6027\u78ba\u8a8d\u3092\u884c\u3046\u3053\u3068<\/li>\n\n\n\n<li>GC\/MS\u5206\u6790\u524d\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30eb\u306e\u6fc3\u7e2e\u3092\u884c\u3046\u3053\u3068<\/li>\n\n\n\n<li>GC\u6ce8\u5165\u524d\u306b\u6e7f\u6c17\u3092\u53d6\u308a\u9664\u304f\u305f\u3081\u306b\u5f79\u7acb\u3064\u30c9\u30e9\u30a4\u30d1\u30fc\u30b8\u3092\u884c\u3046\u3053\u3068<\/li>\n\n\n\n<li>ppt\u30ec\u30d9\u30eb\u306e\u611f\u5ea6\u304c\u3042\u308b\u3053\u3068<\/li>\n\n\n\n<li>\u5206\u6790\u6cd5\u306b\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u3053\u3068<\/li>\n\n\n\n<li>\u5358\u4e00\u306e\u88c5\u7f6e\u3067\u5e83\u7bc4\u56f2\u306eVOC\u306e\u53ce\u96c6\u304c\u53ef\u80fd\u306a\u3053\u3068<\/li>\n\n\n\n<li>\u672a\u77e5\u306e\u7269\u8cea\u306e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u5f79\u7acb\u3064\u3053\u3068<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u3092\u5b8c\u5168\u306a\u72b6\u614b\u3067\u4fdd\u5b58\u3057\u3001\u6e05\u6d44\u306a\u30c7\u30d0\u30a4\u30b9\u306e\u6c5a\u67d3\u3092\u9632\u3050\u305f\u3081\u306b\u306f\u3001\u5bc6\u9589\u6027\u304c\u91cd\u8981\u3067\u3042\u308b\u3053\u3068<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u3068\u30ad\u30e3\u30cb\u30b9\u30bf\u306e\u76f8\u9055\u70b9\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30ad\u30e3\u30cb\u30b9\u30bf<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u30e1\u30bd\u30c3\u30c9<\/td><td class=\"has-text-align-left\" data-align=\"left\">US EPA TO-17<br>ASTM D6196<br>ISO 16017, ISO 16000-6<br>NIOSH 2549<\/td><td class=\"has-text-align-left\" data-align=\"left\">US EPA TO-14, TO-15<br>ASTM D5466<br>OSHA PV2120<br>NIOSH Protocol Draft<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e16\u754c\u898f\u6a21\u306e\u53d7\u5bb9\u5ea6<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7c73\u56fd\u74b0\u5883\u5927\u6c17\u5e02\u5834\u306e\u81f3\u9069\u57fa\u6e96<\/td><\/tr><tr><td>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u74b0\u5883\u5927\u6c17\u3001\u5ba4\u5185\u7a7a\u6c17\u3001\u7523\u696d\u885b\u751f<br>\u6750\u6599\u304b\u3089\u306e\u6392\u51fa\u6210\u5206<br>\u98df\u54c1\u304a\u3088\u3073\u9999\u6599<br>\u5316\u5b66\u5175\u5668<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u74b0\u5883\u5927\u6c17\u3001\u5ba4\u5185\u7a7a\u6c17\u3001\u63ee\u767a\u6027\u7269\u8cea\u306e\u4fb5\u5165\u3001\u7dca\u6025\u5bfe\u5fdc<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">C3 \u304b\u3089 C30<\/td><td class=\"has-text-align-left\" data-align=\"left\">C4 \u304b\u3089 C10 \u307e\u3067<\/td><\/tr><tr><td>\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u500b\u4eba\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3084\u4e00\u822c\u7684\u306a\u4f7f\u3044\u3084\u3059\u3055\u306e\u305f\u3081\u306b\u8efd\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u304d\u304f\u3066\u91cd\u3044<br>\u767a\u9001\u306b\u30b3\u30b9\u30c8\u304c\u304b\u304b\u308b<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30dd\u30f3\u30d7\u3092\u4f7f\u7528\u3057\u305f\u30a2\u30af\u30c6\u30a3\u30d6\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3001\u307e\u305f\u306f\u5404\u5316\u5408\u7269\u306e\u62e1\u6563\u4fc2\u6570\u304c\u6c7a\u307e\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u30dd\u30f3\u30d7\u3092\u4f7f\u7528\u3057\u306a\u3044\u30d1\u30c3\u30b7\u30d6\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u304c\u53ef\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30dd\u30f3\u30d7\u306a\u3057\u3067\u30d1\u30c3\u30b7\u30d6\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u304c\u53ef\u80fd<br>\u30d0\u30c3\u30c6\u30ea\u30fc\u306e\u5145\u96fb\u306a\u3057\u3067\u9577\u671f\u9593\u306e\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u304c\u53ef\u80fd<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a4\u30f3\u30c6\u30b0\u30ec\u30fc\u30c8\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306e\u307f\u3000<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b0\u30e9\u30d6\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u304a\u3088\u3073\u30a4\u30f3\u30c6\u30b0\u30ec\u30fc\u30c8\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6fc3\u7e2e\u30b5\u30f3\u30d7\u30eb<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u6c17\u5168\u4f53<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5206\u6790\u624b\u6cd5\u3067\u63a8\u5968\u3055\u308c\u308b\u9069\u5207\u306a\u5438\u7740\u5264\u306e\u9078\u629e\u304c\u5fc5\u8981<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8a72\u5f53\u4e8b\u9805\u306a\u3057<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30eb\u640d\u5931\u3084\u5438\u7740\u5264\u3078\u306e\u4e0d\u53ef\u9006\u7684\u306a\u5438\u7740\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u5438\u7740\u5264\u306e\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u5bb9\u91cf\u4ee5\u4e0b\u3067\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8a72\u5f53\u4e8b\u9805\u306a\u3057<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">100L\u307e\u3067\u306e\u5927\u304d\u306a\u30b5\u30f3\u30d7\u30eb\u5bb9\u91cf<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30eb\u5bb9\u91cf\u306f\u30ad\u30e3\u30cb\u30b9\u30bf\u30b5\u30a4\u30ba\u306b\u4f9d\u5b58\u3057\u3001\u6700\u592715L<\/td><\/tr><tr><td>\u5206\u6790<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c1\u30e5\u30fc\u30d6\u30b5\u30a4\u30ba\u306f\u88c5\u7f6e\u3054\u3068\u306b\u7570\u306a\u308b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u3059\u3079\u3066\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u30b5\u30f3\u30d7\u30eb\u6fc3\u7e2e\u5668\u3068\u4e92\u63db\u6027\u3042\u308a<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6ce8\u5165\u306f1\u56de\u3001\u88c5\u7f6e\u306b\u3088\u3063\u3066\u306f\u305d\u308c\u4ee5\u4e0a\u306e\u6ce8\u5165\u3082\u53ef\u80fd<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306f\u8907\u6570\u56de\u53ef\u80fd<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6fc3\u5ea6\u7bc4\u56f2 ppt \u304b\u3089 ppm&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">ppt \u304b\u3089 ppm<\/td><\/tr><tr><td>&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e00\u90e8\u306e\u5438\u7740\u6750\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u610f\u56f3\u3057\u306a\u3044\u5909\u5316\u3084\u751f\u6210\u7269\u304c\u751f\u3058\u308b<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u9069\u5207\u306b\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3055\u308c\u305f\u5834\u5408\u3001\u5206\u6790\u306e\u4fe1\u983c\u6027\u306f\u9ad8\u3044<\/td><\/tr><tr><td>\u4fdd\u7ba1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30de\u30eb\u30c1\u30d9\u30c3\u30c9\u30c1\u30e5\u30fc\u30d6\u306e\u5834\u5408\u30014\u2103\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u4fdd\u7ba1\u3092\u63a8\u5968\uff08\u5316\u5408\u7269\u304c\u3088\u308a\u4fdd\u6301\u6027\u306e\u9ad8\u3044\u5438\u7740\u5264\u306b\u79fb\u52d5\u3057\u3001\u56de\u53ce\u304c\u56f0\u96e3\u306b\u306a\u308b\u53ef\u80fd\u6027\u3092\u9632\u3050\u305f\u3081\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5ba4\u6e29\u3067\u53ef<\/td><\/tr><tr><td>\u30af\u30ea\u30fc\u30cb\u30f3\u30b0<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u518d\u5229\u7528\u306e\u305f\u3081\u306b\u5206\u6790\u30d7\u30ed\u30bb\u30b9\u306b\u304a\u3044\u3066\u30c1\u30e5\u30fc\u30d6\u3092\u81ea\u52d5\u7684\u306b\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3001\u5206\u6790\u3068\u540c\u6642\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u30011\u3064\u306e\u71b1\u8131\u7740\u30e6\u30cb\u30c3\u30c8\u306b\u7d44\u307f\u8fbc\u307e\u308c\u305f\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\/\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u5206\u6790<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30ad\u30e3\u30cb\u30b9\u30bf\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u306f\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u78ba\u8a8d\u3068\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u306b\u5148\u7acb\u3064\u8ffd\u52a0\u306e\u30b9\u30c6\u30c3\u30d7\u3068\u3057\u3066\u5225\u500b\u306e\u88c5\u7f6e\u304c\u5fc5\u8981<\/td><\/tr><tr><td>\u30b3\u30b9\u30c8<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5404 $50-130<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5404 $200-700&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u52a0\u71b1\u8131\u7740\u30c1\u30e5\u30fc\u30d6\u3068\u30ad\u30e3\u30cb\u30b9\u30bf\u306e\u985e\u4f3c\u70b9\u3068\u76f8\u9055\u70b9\u3092\u5217\u6319\u3057\u3001\u3069\u3061\u3089\u306e\u88c5\u7f6e\u304c\u3042\u306a\u305f\u306e\u5206\u6790\u306b\u6700\u9069\u304b\u3092\u5224\u65ad\u3059\u308b\u969b\u306b\u5f79\u7acb\u3064\u6bd4\u8f03\u3092\u3054\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2272,2271],"post-badge":[],"resource-type":[],"product-library":[2557,2561,2551],"resource-technique":[2339],"ppma_author":[2814],"class_list":["post-43753","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","product-library-canisters-accessories-ja","product-library-personal-air-samplers-accessories-ja","product-library-air-gas-sampling-products-ja","resource-technique-air-sampling-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"product-library":[{"value":2557,"label":"\u30ad\u30e3\u30cb\u30b9\u30bf\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2561,"label":"\u30d1\u30fc\u30bd\u30ca\u30eb\u30a8\u30a2\u30b5\u30f3\u30d7\u30e9\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2551,"label":"\u5927\u6c17\uff5c\u30ac\u30b9 \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"}],"resource-technique":[{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43753"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43753\/revisions"}],"predecessor-version":[{"id":96859,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43753\/revisions\/96859"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43753"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43753"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43753"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43753"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43753"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43753"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43753"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43753"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}