{"id":43762,"date":"2025-12-17T00:00:00","date_gmt":"2025-12-17T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/ezgc-online-tools-japan\/"},"modified":"2026-07-31T21:02:20","modified_gmt":"2026-07-31T21:02:20","slug":"ezgc-online-tools-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan","title":{"rendered":"<em>GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u52a0\u901f\u3059\u308bEZ<\/em>GC\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u306e\u6d3b\u7528"},"content":{"rendered":"\n<ul id=\"callout&quot;\" class=\"wp-block-list\">\n<li><strong>\u77ed\u6642\u9593\u3067\u65b0\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a<\/strong>&#8212;\u3044\u3064\u3082\u306e\u30c7\u30b9\u30af\u304b\u3089\u76f4\u63a5\u64cd\u4f5c\u53ef\u80fd<\/li>\n\n\n\n<li><strong>\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u3092\u6700\u9069\u5316\u30fb\u6539\u826f<\/strong>&#8212;\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3060\u3051\u3042\u308c\u3070\u3001\u305d\u308c\u3067OK\uff01<\/li>\n\n\n\n<li><strong>\u751f\u7523\u6027\u3092\u5411\u4e0a<\/strong>&#8212;\u7121\u6599\u3067\u4f7f\u3044\u3084\u3059\u3044\u30aa\u30f3\u30e9\u30a4\u30f3\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u3001\u6642\u9593\u7bc0\u7d04\u3001\u78ba\u5b9f\u6027\u5f37\u5316<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43762_44802d-8a{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43762_44802d-8a .kt-button{font-weight:normal;font-style:normal;}.kt-btns43762_44802d-8a .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_44802d-8a .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43762_44802d-8a\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button{font-size:var(--global-kb-font-size-lg, 2rem);border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-right-radius:20px;border-bottom-left-radius:20px;border-top:1px solid;border-right:1px solid;border-bottom:1px solid;border-left:1px solid;padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button{border-top:1px solid;border-right:1px solid;border-bottom:1px solid;border-left:1px solid;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn43762_3fe273-e9.kb-button{border-top:1px solid;border-right:1px solid;border-bottom:1px solid;border-left:1px solid;}}<\/style><a class=\"kb-button kt-button button kb-btn43762_3fe273-e9 kt-btn-size-xlarge kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/ez.restek.com\/proezgc\/en\/ja\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\">RMX\u30ab\u30e9\u30e0\u306e\u5206\u6790\u6761\u4ef6\u4f5c\u6210\u306f\u3053\u3061\u3089<\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-ic_beaker kt-btn-icon-side-right\"><svg viewBox=\"0 0 8 8\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M1.34 0a.5.5 0 0 0 .16 1h.5v1.41c-.09.17-1.2 2.31-1.66 3.09-.16.26-.34.61-.34 1.06 0 .39.15.77.41 1.03s.64.41 1.03.41h5.13c.38 0 .74-.16 1-.41h.03c.26-.26.41-.64.41-1.03 0-.45-.19-.8-.34-1.06-.46-.78-1.57-2.92-1.66-3.09v-1.41h.5a.5.5 0 1 0 0-1h-5a.5.5 0 0 0-.09 0 .5.5 0 0 0-.06 0zm1.66 1h2v1.63l.06.09s.63 1.23 1.19 2.28h-4.5c.56-1.05 1.19-2.28 1.19-2.28l.06-.09v-1.63z\"\/><\/svg><\/span><\/a><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e<em>EZ<\/em>GC\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u306f\u3001PC\u307e\u305f\u306fMac\u3001\u30c7\u30b9\u30af\u30c8\u30c3\u30d7\u307e\u305f\u306f\u30bf\u30d6\u30ec\u30c3\u30c8\u306a\u3069\u304b\u3089\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3067\u76f4\u9762\u3059\u308b\u69d8\u3005\u306a\u8ab2\u984c\u306b\u5bfe\u3057\u3001\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u3055\u308c\u305f\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002Restek\u306e\u5c02\u9580\u77e5\u8b58\u304c\u8a70\u307e\u3063\u305f<em>EZ<\/em>GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30c4\u30fc\u30eb\u306f\u3001\u6642\u9593\u3084\u5834\u6240\u3092\u9078\u3070\u305a\u4f7f\u7528\u3067\u304d\u3001\u624b\u9806\u3082\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002\u8cb4\u793e\u306eGC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u305c\u3072\u3054\u6d3b\u7528\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\"><strong>Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">WCOT\u304a\u3088\u3073PLOT\u30ab\u30e9\u30e0\u7528\u306ePro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\uff08\u300c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\u30fc\u300d\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff09\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u306a\u69cb\u6210\u306a\u306e\u3067\u76f4\u611f\u7684\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u3088\u308a\u81ea\u5728\u306b\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u305f\u3081\u306e\u3001\u69d8\u3005\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3082\u5145\u5b9f\u3057\u3066\u3044\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u624b\u9806\u3067Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u3092\u8a66\u3057\u3066\u307f\u3066\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u304a\u624b\u6301\u3061\u306e\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u63a8\u5968\u3059\u308b\u30ab\u30e9\u30e0\u3092\u9078\u629e<\/li>\n\n\n\n<li>\u30e9\u30a4\u30d6\u30e9\u30ea\u304b\u3089\u76ee\u7684\u306e\u5316\u5408\u7269\u3092\u9078\u629e<\/li>\n\n\n\n<li>\u691c\u51fa\u30e2\u30fc\u30c9\uff08\u691c\u51fa\u5668\uff09\u306e\u9078\u629e\uff1a\u81ea\u52d5\u7684\u306b\u540c\u91cd\u4f53\u3092\u5206\u96e2\u3057\u305f\u3044\u5834\u5408GC-MS\u30e2\u30fc\u30c9\u3092\u9078\u629e\uff0fMS\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306b\u306fGC\u30e2\u30fc\u30c9\u3092\u9078\u629e<\/li>\n\n\n\n<li>\u5206\u96e2\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306a\u308b\u5316\u5408\u7269\u3092\u9078\u629e<\/li>\n\n\n\n<li>GC\u6761\u4ef6\u3092\u5909\u66f4\u3057\u3001\u77ed\u6642\u9593\u3067\u30e2\u30c7\u30eb\u3092\u7c21\u5358\u306b\u6700\u9069\u5316<\/li>\n\n\n\n<li>\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u8a2d\u5b9a\uff1a\u7e70\u308a\u8fd4\u3057\u8abf\u6574\u53ef\u80fd<\/li>\n\n\n\n<li>\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048<\/li>\n\n\n\n<li>\u6d41\u91cf\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff08\u5b9a\u6d41\u91cf\u3001\u5b9a\u5727\u3001\u5b9a\u7dda\u901f\u5ea6\uff09\u306e\u5909\u66f4<\/li>\n\n\n\n<li>\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3067\u6eb6\u51fa\u6e29\u5ea6\u3092\u30c1\u30a7\u30c3\u30af<\/li>\n\n\n\n<li>\u8907\u6570\u306e\u56fa\u5b9a\u76f8\u3092\u6bd4\u8f03\u3057\u3066\u7d50\u679c\u3092\u78ba\u8a8d<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3069\u3093\u306a\u3068\u304d\u306b\u4f7f\u3046\uff1f:&nbsp;<\/strong>&nbsp;\u30ab\u30e9\u30e0\u306e\u9078\u5b9a\u542b\u3081\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u30bc\u30ed\u304b\u3089\u958b\u767a\u3059\u308b\u3068\u304d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u306a\u306b\u3092\u6e96\u5099\u3059\u308c\u3070\u3088\u3044\uff1f:<\/strong>&nbsp; \u5206\u6790\u5bfe\u8c61\u6210\u5206\u30ea\u30b9\u30c8\uff08\u30ab\u30e9\u30e0\u6307\u5b9a\u3082\u53ef\uff09\u304c\u3042\u308c\u3070OK\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6700\u7d42\u6210\u679c\u7269\u306f\u306a\u306b\uff1f:<\/strong>&nbsp; \u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u53ef\u80fd\u306a\u3001\u30a4\u30f3\u30bf\u30e9\u30af\u30c6\u30a3\u30d6\u306a\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u7279\u5b9a\u306e\u56fa\u5b9a\u76f8\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3001\u304a\u3088\u3073\u6761\u4ef6\u3082\u4e00\u7dd2\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u5909\u66f4\u3001\u6761\u4ef6\u306e\u8abf\u6574\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u62e1\u5927\u3084\u5316\u5b66\u69cb\u9020\u306e\u78ba\u8a8d\u3001\u3055\u3089\u306b\u306f\u5171\u6eb6\u51fa\u5316\u5408\u7269\u306e\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3092\u91cd\u306d\u3066\u8868\u793a\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43762_e4c644-2b{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43762_e4c644-2b .kt-button{font-weight:normal;font-style:normal;}.kt-btns43762_e4c644-2b .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_e4c644-2b .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43762_e4c644-2b\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43762_14a159-d0.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43762_14a159-d0.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43762_14a159-d0.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43762_14a159-d0.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43762_14a159-d0 kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/ez.restek.com\/proezgc\/en\/ja\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">\u4eca\u3059\u3050\u59cb\u3081\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\"><strong><em>EZ<\/em>GC Method Translator and Flow Calculator<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><em>EZ<\/em>GC Method Translator\u3068<em>EZ<\/em>GC Flow Calculator\u3092\u4f7f\u3048\u3070\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3084\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5909\u66f4\u3001\u307e\u305f\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u30b9\u30d4\u30fc\u30c9\u3084\u52b9\u7387\u306e\u6700\u9069\u5316\u3092\u30b7\u30f3\u30d7\u30eb\u306a\u624b\u9806\u3067\u884c\u3048\u307e\u3059\u3002\u30e1\u30bd\u30c3\u30c9\u306e\u4ed5\u69d8\u3092\u5165\u529b\u3057\u3055\u3048\u3059\u308c\u3070\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3088\u3063\u3066\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u304c\u8a08\u7b97\u3055\u308c\u3001\u540c\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<em>EZ<\/em>GC Method Translator\u3068<em>EZ<\/em>GC Flow Calculator\u3092\u6d3b\u7528\u3057\u3066\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3069\u3093\u306a\u3068\u304d\u306b\u4f7f\u3046\uff1f:&nbsp;&nbsp;<\/strong>\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\/\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5909\u66f4\u3001\u307e\u305f\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u30b9\u30d4\u30fc\u30c9\/\u52b9\u7387\u306e\u6700\u9069\u5316\u304c\u5fc5\u8981\u306a\u3068\u304d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u306a\u306b\u3092\u6e96\u5099\u3059\u308c\u3070\u826f\u3044\uff1f:<\/strong>&nbsp;&nbsp;\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u60c5\u5831\u304c\u3042\u308c\u3070OK\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6700\u7d42\u6210\u679c\u7269\u306f\u306a\u306b\uff1f:<\/strong>&nbsp; \u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u3068\u540c\u7b49\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5b9f\u73fe\u3059\u308bGC\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3001\u5206\u6790\u6642\u9593\u3001\u5e73\u5747\u7dda\u901f\u5ea6\u3001\u6d41\u91cf\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6642\u9593\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u3059\u3079\u3066\u304c\u4f7f\u3044\u3084\u3059\u3044\u30b7\u30f3\u30b0\u30eb\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3067\u63d0\u4f9b\u3055\u308c\u3001\u30c4\u30fc\u30eb\u9593\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u5207\u308a\u66ff\u3048\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43762_a86c4c-d7{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43762_a86c4c-d7 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43762_a86c4c-d7 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43762_a86c4c-d7\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43762_c71cfd-7b.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43762_c71cfd-7b.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43762_c71cfd-7b.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43762_c71cfd-7b.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43762_c71cfd-7b kt-btn-size-large kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/ja\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">\u4eca\u3059\u3050\u59cb\u3081\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EZGC\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u3092\u4f7f\u3063\u3066\u3001GC\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3001\u6700\u9069\u5316\u3001\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u7c21\u5358\u306b\u884c\u3044\u3001\u751f\u7523\u6027\u3092\u5411\u4e0a\u3002\u76f4\u611f\u7684\u306b\u64cd\u4f5c\u3067\u304d\u308b\u30c4\u30fc\u30eb\u3067\u6642\u9593\u3092\u7bc0\u7d04\u3057\u3001\u78ba\u5b9f\u306a\u7d50\u679c\u3092\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7285,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2552],"resource-technique":[2340],"ppma_author":[414,2814],"class_list":["post-43762","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNOT3445-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."},{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43762"}],"version-history":[{"count":11,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43762\/revisions"}],"predecessor-version":[{"id":86835,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43762\/revisions\/86835"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7285"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43762"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43762"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43762"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43762"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43762"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43762"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}