{"id":43784,"date":"2024-07-24T00:00:00","date_gmt":"2024-07-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials-japan\/"},"modified":"2026-04-28T19:35:37","modified_gmt":"2026-04-28T19:35:37","slug":"thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot4328-ja\/thermal-desorption-gas-chromatography-mass-spectrometry-td-gc-ms-analysis-of-pfas-used-in-food-contact-materials-japan","title":{"rendered":"PFAS\u5206\u6790\u306e\u9769\u65b0\uff1a\u98df\u54c1\u63a5\u89e6\u6750\u6599\uff08FCM\uff09\u306b\u304a\u3051\u308b\u71b1\u8131\u7740-\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u8cea\u91cf\u5206\u6790\u6cd5\uff08TD-GC-MS\uff09\u306e\u5fdc\u7528"},"content":{"rendered":"\n<p><strong>\u8457\u8005:<\/strong> Nancy Wolf<sup>1<\/sup>, Lina M\u00fcller<sup>1<\/sup>, Sarah Enge<sup>1<\/sup>, Tina Ungeth\u00fcm<sup>1<\/sup>, Thomas J. Simat<sup>1<\/sup><br>1. Chair of Food Science and Food Contact Materials, TU Dresden, Dresden<\/p>\n\n\n\n<p><strong>\u516c\u958b\u5143:<\/strong> Food Additives &amp; Contaminants: Part A<\/p>\n\n\n\n<p><strong>\u516c\u958b\u5e74:<\/strong> 2024\u5e74<\/p>\n\n\n\n<p><strong>\u672c\u6587\u5168\u6587\u306e\u30ea\u30f3\u30af:<\/strong> <a href=\"https:\/\/doi.org\/10.1080\/19440049.2024.2370371\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1080\/19440049.2024.2370371\uff08\u82f1\u6587\u306e\u307f\uff09<\/a><\/p>\n\n\n\n<p><strong>\u8981\u7d04:<\/strong> \u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306f\u3001\u30ad\u30c3\u30c1\u30f3\u7528\u54c1\u5411\u3051\u306ePTFE\u30d9\u30fc\u30b9\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u9020\u88dc\u52a9\u5264\u3084\u3001\u7d19\u3084\u30dc\u30fc\u30c9\u306e\u6dfb\u52a0\u7269\u3068\u3044\u3063\u305f\u98df\u54c1\u63a5\u89e6\u6750\u6599 (FCM) \u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u4f7f\u7528\u304c\u5897\u3048\u308b\u4e00\u65b9\u3067\u3001PFAS\u304c\u74b0\u5883\u3084\u5065\u5eb7\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306b\u5bfe\u3059\u308b\u61f8\u5ff5\u304c\u9ad8\u307e\u3063\u3066\u304d\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001FCM\u306b\u542b\u307e\u308c\u308bPFAS\u6fc3\u5ea6\u3084\u3001FCM\u304b\u3089\u98df\u54c1\u3078\u306e\u79fb\u884c\u72b6\u6cc1\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u91cd\u8981\u6027\u304c\u5897\u3057\u3066\u3044\u307e\u3059\uff08PFAS\u95a2\u9023\u60c5\u5831\u306f<a href=\"https:\/\/www.restek.com\/PFAS-JP\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/PFAS-JP<\/a>\u304b\u3089\u78ba\u8a8d\u3067\u304d\u307e\u3059\uff09&nbsp;\u3002<\/p>\n\n\n\n<p>\u672c\u7814\u7a76\u3067\u306f\u3001\u71b1\u8131\u7740-\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u8cea\u91cf\u5206\u6790\u6cd5\uff08TD-GC-MS\uff09\u3092\u7528\u3044\u305fPFAS\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067GC-MS\u306b\u3088\u308b\u5206\u6790\u306f\u30d5\u30c3\u7d20\u30c6\u30ed\u30de\u30fc\u30a2\u30eb\u30b3\u30fc\u30eb\uff08FTOHs\uff09\u306e\u307f\u304c\u5bfe\u8c61\u3067\u3057\u305f\u304c\u3001\u4eca\u56de\u306e\u7814\u7a76\u306b\u3088\u308a\u3001\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30ab\u30eb\u30dc\u30f3\u9178\uff08PFCAs\uff09\u3001\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a8\u30fc\u30c6\u30eb\u30ab\u30eb\u30dc\u30f3\u9178\uff08PFECAs\uff09\u3001\u304a\u3088\u3073\u305d\u308c\u3089\u306e\u71b1\u5206\u89e3\u751f\u6210\u7269\u3067\u3042\u308b\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a8\u30fc\u30c6\u30eb\uff08PFEs\uff09\u3084\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30b1\u30f3\u3082\u3001\u4e8b\u524d\u306e\u8a98\u5c0e\u4f53\u5316\u306a\u3057\u306bGC-MS\u3067\u5206\u6790\u3067\u304d\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002<br>PFCA\u3068FTOH\u306e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u306f\u3001\u96fb\u5b50\u885d\u6483\u30a4\u30aa\u30f3\u5316\uff08EI\uff09\u3092\u7528\u3044\u305f\u7279\u7570\u7684\u306aSIM\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u5206\u6790\u3092\u63a1\u7528\u3057\u3001\u5316\u5408\u7269\u306e\u540c\u5b9a\u306f\u3001EI\u30b9\u30ad\u30e3\u30f3\u304a\u3088\u3073\u5316\u5b66\u30a4\u30aa\u30f3\u5316\uff08CI\uff09SIM\u6e2c\u5b9a\u306b\u3088\u3063\u3066\u884c\u3044\u307e\u3057\u305f\u3002TD-GC-MS\u88c5\u7f6e\u306b\u304a\u3051\u308bPFCAs\u3001FTOHs\u3001\u304a\u3088\u3073PFECAs\u306e\u691c\u51fa\u9650\u754c\uff08LOD\uff09\u306f\u3001pg\u30ec\u30d9\u30eb\u3068\u4f4e\u3044\u7bc4\u56f2\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001TD-GC-MS\u6e2c\u5b9a\u4e2d\u306ePFCAs\u3068PFECAs\u306e\u71b1\u5206\u89e3\u306b\u3064\u3044\u3066\u3082\u8abf\u67fb\u3092\u884c\u3063\u305f\u305f\u3081\u3001\u5408\u308f\u305b\u3066\u5831\u544a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p><strong>\u8b1d\u8f9e:<\/strong> \u3053\u306e\u5206\u6790\u306b\u306f\u3001Restek\u306eRtx-200ms\u30ab\u30e9\u30e0 (cat.# 15653)\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 Rtx-200ms\u30ab\u30e9\u30e0\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss4041-ja\/rtx-200-gc-columns-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNSS4041-JA\/rtx-200-gc-columns-japan\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/15653\">                                \u30ab\u30bf\u30ed\u30b0No. 15653                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-200ms GC Capillary Column, 30 m, 0.25 mm ID, 1.00 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/15653\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11807\">                                \u30ab\u30bf\u30ed\u30b0No. 11807                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-200\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11807\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306e\u5206\u6790\u306b\u95a2\u3059\u308b\u6700\u65b0\u306e\u7814\u7a76\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u98df\u54c1\u63a5\u89e6\u6750\u6599\uff08FCM\uff09\u306b\u304a\u3051\u308bPFAS\u6fc3\u5ea6\u3068FCM\u304b\u3089\u306ePFAS\u306e\u98df\u54c1\u3078\u306e\u79fb\u884c\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u305f\u3081\u3001\u71b1\u8131\u7740-\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u8cea\u91cf\u5206\u6790\u6cd5\uff08TD-GC-MS\uff09\u3092\u7528\u3044\u305f\u9769\u65b0\u7684\u306a\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u5f93\u6765\u306e\u65b9\u6cd5\u3067\u306f\u5206\u6790\u3067\u304d\u306a\u304b\u3063\u305f\u5316\u5408\u7269\u3082\u691c\u51fa\u53ef\u80fd\u306b\u306a\u3063\u305f\u3001\u98df\u54c1\u5b89\u5168\u6027\u5411\u4e0a\u306b\u5bc4\u4e0e\u3059\u308b\u3053\u306e\u7814\u7a76\u306e\u8a73\u7d30\u3092\u305c\u3072\u30c1\u30a7\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[2760],"industries-application":[2288,2271,2275,2274],"post-badge":[],"resource-type":[],"product-library":[2552],"resource-technique":[2339,2340,2345],"ppma_author":[722,709,743,758,757],"class_list":["post-43784","post","type-post","status-publish","format-standard","hentry","category-articles-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-food-safety-ja","industries-application-food-beverage-ja","product-library-gas-chromatography-products-ja","resource-technique-air-sampling-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"SaVanna Cano","author_link":"https:\/\/discover.restek.com\/ja\/author\/savanna-cano\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":789,"category_count":457,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":49,"filter":"raw"}],"authors":[{"term_id":722,"user_id":0,"is_guest":1,"slug":"nancy-wolf","display_name":"Nancy Wolf","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":709,"user_id":0,"is_guest":1,"slug":"lina-muller","display_name":"Lina M\u00fcller","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":743,"user_id":0,"is_guest":1,"slug":"sarah-enge","display_name":"Sarah Enge","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":758,"user_id":0,"is_guest":1,"slug":"tina-ungethum","display_name":"Tina Ungeth\u00fcm","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":757,"user_id":0,"is_guest":1,"slug":"thomas-j-simat","display_name":"Thomas J. Simat","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43784"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43784\/revisions"}],"predecessor-version":[{"id":81013,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43784\/revisions\/81013"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43784"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43784"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43784"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43784"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43784"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43784"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43784"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43784"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}