{"id":43793,"date":"2025-10-03T21:40:45","date_gmt":"2025-10-03T21:40:45","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/exploring-the-volatile-profile-of-whiskey-samples-using-solid-phase-microextraction-arrow-and-comprehensive-two-dimensional-gas-chromatography-mass-spectrometry-japan\/"},"modified":"2025-11-20T23:11:49","modified_gmt":"2025-11-20T23:11:49","slug":"exploring-the-volatile-profile-of-whiskey-samples-using-solid-phase-microextraction-arrow-and-comprehensive-two-dimensional-gas-chromatography-mass-spectrometry-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot5224-ja\/exploring-the-volatile-profile-of-whiskey-samples-using-solid-phase-microextraction-arrow-and-comprehensive-two-dimensional-gas-chromatography-mass-spectrometry-japan","title":{"rendered":"\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa\uff08SPME\uff09 Arrow\u3068\u5305\u62ec\u7684\u306a\u4e8c\u6b21\u5143\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u8cea\u91cf\u5206\u6790\u6cd5\u3092\u7528\u3044\u305f\u30a6\u30a4\u30b9\u30ad\u30fc\u30b5\u30f3\u30d7\u30eb\u306e\u63ee\u767a\u6027\u6210\u5206\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306e\u63a2\u7d22"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>\u8457\u8005:<\/strong> Antonio Ferracane<sup>1,2<\/sup>, Natalia Manousi<sup>2,3<\/sup>, Peter Q. Tranchida<sup>1<\/sup>, George A. Zachariadis<sup>3<\/sup>, Luigi Mondello<sup>1,4,5<\/sup>, Erwin Rosenberg<sup>2 ssd<\/sup><br>1. Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy, 2. Institute of Chemical Technology and Analytics, Vienna University of Technology, Getreidemarkt 9\/164, Vienna 1060, Austria, 3. Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece, 4. Chromaleont s.r.l., c\/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy, 5. Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, Rome, Italy<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u767a\u884c\u5143:<\/strong> Journal of Chromatography A<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u767a\u884c:<\/strong> Volume: 1676\u3000<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u767a\u884c\u5e74:<\/strong> 2022\u5e74<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30ea\u30f3\u30af:<\/strong> <a href=\"https:\/\/doi.org\/10.1016\/j.chroma.2022.463241\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.chroma.2022.463241<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8981\u7d04: <\/strong>\u672c\u7814\u7a76\u3067\u306f\u3001\u7db2\u7f85\u7684\u4e00\u6589\u5206\u6790\u3092\u53ef\u80fd\u3068\u3059\u308b\u4e8c\u6b21\u5143\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\u00d7GC\uff09\u3068\u8cea\u91cf\u5206\u6790\uff08MS\uff09\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u624b\u6cd5\u3092\u7528\u3044\u3066\u3001\u30a6\u30a4\u30b9\u30ad\u30fc\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3092\u5b9a\u91cf\u3059\u308b\u305f\u3081\u306e\u65b0\u3057\u3044\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3092\u63d0\u6848\u3057\u307e\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u3001\u30a2\u30a4\u30ea\u30c3\u30b7\u30e5\u30a6\u30a4\u30b9\u30ad\u30fc\u3001\u30b7\u30f3\u30b0\u30eb\u30e2\u30eb\u30c8\u30b9\u30b3\u30c3\u30c1\u30a6\u30a4\u30b9\u30ad\u30fc\u3001\u30d6\u30ec\u30f3\u30c7\u30c3\u30c9\u30b9\u30b3\u30c3\u30c1\u30a6\u30a4\u30b9\u30ad\u30fc\u3068\u3044\u3063\u305f\u7570\u306a\u308b\u7a2e\u985e\u306e\u30a6\u30a4\u30b9\u30ad\u30fc\u306b\u542b\u307e\u308c\u308b\u3001\u5b98\u80fd\u7279\u6027\u3084\u6d88\u8cbb\u8005\u306e\u55dc\u597d\u306b\u91cd\u8981\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u3092\u52b9\u7387\u7684\u306b\u62bd\u51fa\u30fb\u6fc3\u7e2e\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3001\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa\uff08SPME\uff09Arrow\u6280\u8853\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002<br>\u672c\u624b\u6cd5\u3092\u6700\u9069\u5316\u3057\u305f\u5f8c\u3001\u5f93\u6765\u306eSPME\u6280\u8853\u3068\u6bd4\u8f03\u3057\u305f\u7d50\u679c\u3001\u5316\u5408\u7269\u306e\u7a2e\u985e\u306b\u3088\u3063\u3066\u306f\u611f\u5ea6\u304c\u6700\u59276\u500d\u5411\u4e0a\u3057\u3001\u518d\u73fe\u6027\u3082\u6700\u59275\u500d\u6539\u5584\u3055\u308c\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u307e\u305f\u3001SPME Arrow\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30c6\u30eb\u30da\u30f3\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u3001\u30a8\u30b9\u30c6\u30eb\u3001\u30ab\u30eb\u30dc\u30f3\u9178\u3001\u30b1\u30c8\u30f3\u306a\u3069\u3092\u542b\u3080167\u7a2e\u985e\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3092\u540c\u5b9a\u3067\u304d\u305f\u306e\u306b\u5bfe\u3057\u3001\u5f93\u6765\u306eSPME\u6280\u8853\u3067\u306f126\u7a2e\u985e\u306b\u3068\u3069\u307e\u308a\u307e\u3057\u305f\u3002<br>SPME Arrow\u3092GC\u00d7GC-MS\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u624b\u6cd5\u306f\u3001\u8907\u96d1\u306a\u30b5\u30f3\u30d7\u30eb\u306e\u63ee\u767a\u6027\u6210\u5206\u3092\u8a73\u7d30\u306b\u89e3\u6790\u3059\u308b\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u624b\u6cd5\u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u8abf\u67fb\u5bfe\u8c61\u3068\u306a\u3063\u305f3\u7a2e\u985e\u306e\u30a6\u30a4\u30b9\u30ad\u30fc\u9593\u306b\u304a\u3051\u308b\u91cd\u8981\u306a\u9999\u6c17\u6210\u5206\u306e\u9055\u3044\u3092\u52b9\u679c\u7684\u306b\u8b58\u5225\u3067\u304d\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8b1d\u8f9e: <\/strong>\u3053\u306e\u7814\u7a76\u306f\u3001Restek Academic Support Program (RASP &#8211; Restek, Bellefonte, PA, USA)\u306e\u652f\u63f4\u3092\u53d7\u3051\u884c\u308f\u308c\u307e\u3057\u305f\u3002\u5206\u6790\u306b\u306f\u3001Restek PAL SPME Arrow\u30d5\u30a1\u30a4\u30d0\u30fc (cat.# 27487)\u3001Restek PAL SPME\u30de\u30cb\u30e5\u30a2\u30eb\u6ce8\u5165\u30ad\u30c3\u30c8 (cat.# 27490)\u3001Rtx-5MS-Low-Bleed GC-MS\u30ab\u30e9\u30e0 (cat.# 12623)\u3001\u304a\u3088\u3073Stabilwax-MS GC\u30ab\u30e9\u30e0\u3092\u542b\u3080\u8907\u6570\u306eRestek\u88fd\u54c1\u3082\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u672c\u7814\u7a76\u3067\u306f\u3001\u4e8c\u6b21\u5143\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\u00d7GC\uff09\u3068\u8cea\u91cf\u5206\u6790\uff08MS\uff09\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u30a6\u30a4\u30b9\u30ad\u30fc\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3092\u52b9\u7387\u7684\u306b\u5b9a\u91cf\u3059\u308b\u65b0\u3057\u3044\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3092\u63d0\u6848\u3002SPME Arrow\u6280\u8853\u3092\u7528\u3044\u3066\u3001\u9999\u6c17\u6210\u5206\u306e\u9055\u3044\u3092\u8b58\u5225\u3057\u3001\u611f\u5ea6\u3068\u518d\u73fe\u6027\u304c\u5411\u4e0a\u3057\u305f\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2291,2274],"post-badge":[],"resource-type":[],"product-library":[2583,2555],"resource-technique":[2340,2347,2345],"ppma_author":[657,723,732,683,710,680],"class_list":["post-43793","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-food-quality-ja","industries-application-food-beverage-ja","product-library-spme-ja","product-library-sample-preparation-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-solid-phase-microextraction-spme-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2291,"label":"\u98df\u54c1\uff5c\u54c1\u8cea\u7ba1\u7406"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2583,"label":"SPME"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2347,"label":"\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa (SPME)"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":657,"user_id":86,"is_guest":0,"slug":"antonio-ferracane","display_name":"Antonio Ferracane","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/9241c5ea049b61bb82ebed76012180e1b68d2a637c1461afd994e6aa67254978?s=96&d=mm&r=g","author_category":"1","first_name":"Antonio","last_name":"Ferracane","user_url":"","job_title":"","description":"Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy. Institute of Chemical Technology and Analytics, Vienna University of Technology, Getreidemarkt 9\/164, Vienna 1060, Austria"},{"term_id":723,"user_id":87,"is_guest":0,"slug":"natalia-manousi","display_name":"Natalia Manousi","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/0d82f8019cedef4c0a8e710664e6316367af6bada86488adaa84546c42290cdd?s=96&d=mm&r=g","author_category":"1","first_name":"Natalia","last_name":"Manousi","user_url":"","job_title":"","description":"Institute of Chemical Technology and Analytics, Vienna University of Technology, Getreidemarkt 9\/164, Vienna 1060, Austria. Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece"},{"term_id":732,"user_id":0,"is_guest":1,"slug":"peter-q-tranchida","display_name":"Peter Q. Tranchida","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Peter Q.","last_name":"Tranchida","user_url":"","job_title":"","description":"Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy"},{"term_id":683,"user_id":0,"is_guest":1,"slug":"george-a-zachariadis","display_name":"George A. Zachariadis","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"George A.","last_name":"Zachariadis","user_url":"","job_title":"","description":"Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece"},{"term_id":710,"user_id":0,"is_guest":1,"slug":"luigi-mondello","display_name":"Luigi Mondello","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Luigi","last_name":"Mondello","user_url":"","job_title":"","description":"Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy. Chromaleont s.r.l., c\/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy. Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, Rome, Italy"},{"term_id":680,"user_id":0,"is_guest":1,"slug":"erwin-rosenberg","display_name":"Erwin Rosenberg","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Erwin","last_name":"Rosenberg","user_url":"","job_title":"","description":"Institute of Chemical Technology and Analytics, Vienna University of Technology, Getreidemarkt 9\/164, Vienna 1060, Austria"}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43793"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43793\/revisions"}],"predecessor-version":[{"id":67051,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43793\/revisions\/67051"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43793"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43793"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43793"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43793"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43793"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43793"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}