{"id":43801,"date":"2020-11-16T00:00:00","date_gmt":"2020-11-16T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/mxt-columns-japan\/"},"modified":"2026-04-07T01:59:20","modified_gmt":"2026-04-07T01:59:20","slug":"mxt-columns-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss1368-ja\/mxt-columns-japan","title":{"rendered":"MXT\u30ab\u30e9\u30e0\u304c\u5b9f\u73fe\u3059\u308b\u7a76\u6975\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\uff5c\u9ad8\u6e29GC\u5206\u6790\u7528\u30e1\u30bf\u30eb\u30ab\u30e9\u30e0\uff5c\u30d7\u30ed\u30bb\u30b9GC\u3084\u30dd\u30fc\u30bf\u30d6\u30ebGC\u306b\u6700\u9069\u306a\u91d1\u5c5e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_0df2c4-07{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_0df2c4-07 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_0df2c4-07 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_0df2c4-07 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_0df2c4-07\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_c72c30-20.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_c72c30-20.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_c72c30-20.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_c72c30-20.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_c72c30-20 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/c\/1182\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">MXT<br>\u30ab\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_f55a7f-62{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_f55a7f-62 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_f55a7f-62 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_f55a7f-62 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_f55a7f-62\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_44a729-3e.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_44a729-3e.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_44a729-3e.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_44a729-3e.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_44a729-3e kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/ja\/?s=mxt\"><span class=\"kt-btn-inner-text\">MXT<br>\u95a2\u9023\u6587\u732e\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_0a10c0-0a{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_0a10c0-0a .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_0a10c0-0a .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_0a10c0-0a .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_0a10c0-0a\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_394e11-e0.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_394e11-e0.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_394e11-e0.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_394e11-e0.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_394e11-e0 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/chromatogram-library\/?s=mxt\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">MXT<br>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9ad8\u6e29\u74b0\u5883\u4e0b\u3067\u3082\u5b89\u5b9a\u3057\u305f\u5805\u7262\u6027\u3092\u6301\u3064GC\u30ab\u30e9\u30e0\uff1a\u6700\u9ad8450\u2103\u307e\u3067\u5b89\u5b9a\u7a3c\u50cd<\/strong><\/li>\n\n\n\n<li><strong>\u67d4\u8edf\u306a\u91d1\u5c5e\u30c1\u30e5\u30fc\u30d6\u8a2d\u8a08\uff1a\u6700\u5c0f2.5\u30a4\u30f3\u30c1\u307e\u3067\u306e\u30ab\u30b9\u30bf\u30e0\u30b3\u30a4\u30eb\u5f84\u306b\u5bfe\u5fdc\u3001\u9650\u3089\u308c\u305f\u30b9\u30da\u30fc\u30b9\u306b\u3082\u5b8c\u74a7\u306b\u8a2d\u7f6e\u53ef\u80fd<\/strong><\/li>\n\n\n\n<li><strong>\u72ec\u81ea\u306eSiltek\u51e6\u7406\uff1a\u6700\u9ad8\u30ec\u30d9\u30eb\u306e\u4e0d\u6d3b\u6027\u5ea6\u3092\u5b9f\u73fe\u3001\u6b63\u78ba\u3067\u4fe1\u983c\u6027\u9ad8\u3044\u30c7\u30fc\u30bf\u53d6\u5f97\u304c\u53ef\u80fd\u3000<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Siltek\u51e6\u7406\u3055\u308c\u305f\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u306eMXT WCOT\uff08Wall Coated Open Tubular\uff09\u578b\u30ad\u30e3\u30d4\u30e9\u30ea\u30ab\u30e9\u30e0\u304c\u6700\u9069\u306a\u9078\u629e\u80a2\u3068\u306a\u308b\u306e\u306f\u3001\u9ad8\u6e29\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306a\u3069\u3001\u30ab\u30e9\u30e0\u7834\u640d\u30ea\u30b9\u30af\u304c\u9ad8\u304f\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u304c\u4f7f\u7528\u3067\u304d\u306a\u3044\u3088\u3046\u306a\u74b0\u5883\u3067\u3059\u3002\u73fe\u5834\u8a08\u5668\u3001\u30d7\u30ed\u30bb\u30b9GC\u3001\u5c0f\u578b\u30aa\u30fc\u30d6\u30f3\u642d\u8f09GC\u306a\u3069\u3001\u9650\u3089\u308c\u305f\u30b9\u30da\u30fc\u30b9\u3084\u904e\u9177\u306a\u6761\u4ef6\u4e0b\u3067\u3082\u3001Restek MXT\u30ab\u30e9\u30e0\u306f\u91d1\u5c5e\u306e\u5f37\u976d\u3055\u3068\u30ac\u30e9\u30b9\u4e26\u307f\u306e\u4e0d\u6d3b\u6027\u5ea6\u3092\u4e21\u7acb\u3057\u3001\u5b89\u5b9a\u3057\u305f\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u904e\u9177\u306a\u74b0\u5883\u4e0b\u3067\u3082\u5b89\u5b9a\u3057\u305f\u5805\u7262\u6027\u3092\u6301\u3064\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u306f\u3001\u30dd\u30ea\u30a4\u30df\u30c9\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u9577\u6642\u9593\u9ad8\u6e29\u306b\u3055\u3089\u3055\u308c\u308b\u3053\u3068\u3067\u8106\u5316\u3059\u308b\u305f\u3081\u3001\u901a\u5e38\u306f360\u2103\u4ed8\u8fd1\u3067\u7834\u640d\u3057\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u91d1\u5c5e\u88fdMXT\u30ab\u30e9\u30e0\u306f\u5805\u7262\u3067\u3001\u56fa\u5b9a\u76f8\u306b\u3088\u3063\u3066\u306f\u6700\u9ad8450\u2103\u307e\u3067\u5b89\u5b9a\u7684\u306b\u7a3c\u50cd\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6d3b\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u6642\u306b\u61f8\u5ff5\u6750\u6599\uff08\u4e0d\u6d3b\u6027\u5316\u3084\u5438\u7740\uff09\u3068\u306a\u308b\u91d1\u5c5e\u8868\u9762\u304c\u554f\u984c\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306b\u5bfe\u5fdc\u3057\u305f\u306e\u304cSiltek\u51e6\u7406\u3067\u3059\u3002\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u3068\u540c\u7b49\u306e\u4e0d\u6d3b\u6027\u5ea6\u304c\u9054\u6210\u3055\u308c\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u91d1\u5c5e\u30c1\u30e5\u30fc\u30d6\u3068\u6d78\u900f\u6027Siltek\u51e6\u7406\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u5b9f\u73fe\u3057\u305f\u306e\u306f\u3001\u30d7\u30ed\u30bb\u30b9GC\u3084\u73fe\u5834\u8a08\u5668\u306a\u3069\u306e\u72ed\u3044\u30b9\u30da\u30fc\u30b9\u306b\u3082\u6700\u9069\u306a\u3001MXT\u30ab\u30e9\u30e0\u306e\u6975\u5c0f\u5f84\u30b3\u30a4\u30eb\u5f62\u72b6\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u7279\u5b9a\u306e\u4ed5\u69d8\u306b\u5bfe\u5fdc\u3059\u308b\u30ab\u30b9\u30bf\u30e0\u54c1\u3068\u3057\u3066\u30b3\u30a4\u30eb\u5f842.5\uff5e7\u30a4\u30f3\u30c1\u3067\u306e\u88fd\u4f5c\u3082\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\uff08MXT\u30ab\u30e9\u30e0\u306e\u6a19\u6e96\u7684\u30b3\u30a4\u30eb\u76f4\u5f84\u306f4.5\u30a4\u30f3\u30c1\uff09\u3002\u307e\u305f\u3001MXT\u30c1\u30e5\u30fc\u30d6\u3092\u63a1\u7528\u3057\u305fPLOT\u30ab\u30e9\u30e0\u3082\u3054\u63d0\u4f9b\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5805\u7262\u304b\u3064\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044Restek\u306eMXT\u30ab\u30e9\u30e0\u306f\u3001\u591a\u69d8\u306a\u30dd\u30ea\u30de\u30fc\u76f8\u3067\u63d0\u4f9b\u53ef\u80fd\u306a\u305f\u3081\u3001\u5e45\u5e83\u3044\u7528\u9014\u306b\u5bfe\u5fdc\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001MXT-1HT SimDist\u30ab\u30e9\u30e0\u3084MXT-Biodiesel TG\u30ab\u30e9\u30e0\u306f\u3001\u77f3\u6cb9\u30fb\u77f3\u6cb9\u5316\u5b66\u5206\u91ce\u3067\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u591a\u304f\u306e<a href=\"https:\/\/discover.restek.com\/artikel\/pcar2082\/astm-petrochemical-method-chromatography-product-guide\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/pcar2082\/astm-petrochemical-method-chromatography-product-guide\/\" rel=\"noreferrer noopener\">ASTM Method\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a>\u3067\u305d\u306e\u4fe1\u983c\u6027\u304c\u8a8d\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001MXT\u30ab\u30e9\u30e0\u306e\u5805\u7262\u6027\u3068\u6027\u80fd\u304c\u5b9f\u8a3c\u3055\u308c\u305f\u7d50\u679c\u3068\u3057\u3066\u3001\u5f57\u661f\u306b\u521d\u3081\u3066\u30bd\u30d5\u30c8\u30e9\u30f3\u30c7\u30a3\u30f3\u30b0\u3057\u305f\u30ed\u30bc\u30c3\u30bf\u63a2\u7d22\u6a5f\u306e\u30d5\u30a3\u30e9\u30a8\u30e9\u30f3\u30c0\u2015\u306b\u642d\u8f09\u3055\u308c\u308b\u5206\u6790\u30ab\u30e9\u30e0\u3068\u3057\u3066\u3082\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002MXT-1701\u30ab\u30e9\u30e0\u306f\u5b87\u5b99\u3092\u65c5\u3057\u305f\u521d\u306eGC\u30ab\u30e9\u30e0\u3067\u3057\u305f\u3002\u5b87\u5b99\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306f\u3001Robert Sternberg\u535a\u58eb\u306e\u72ec\u5360\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\uff08<a href=\"https:\/\/discover.restek.com\/articles\/gnot3402\/sitting-down-with-a-chromatography-icon-dr-robert-sternberg\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3402\/sitting-down-with-a-chromatography-icon-dr-robert-sternberg\/\" rel=\"noreferrer noopener\">www.restek.com\/Sternberg\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a>\uff09\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u73fe\u5834\u3001\u7cbe\u88fd\u6240\u3001\u3042\u308b\u3044\u306f\u592a\u967d\u7cfb\u306e\u679c\u3066\u3067\u306e\u5206\u6790\u3067\u3042\u3063\u3066\u3082\u3001Restek\u306e\u91d1\u5c5e\u88fdMXT\u30ab\u30e9\u30e0\u306f\u9ad8\u54c1\u8cea\u304b\u3064\u518d\u73fe\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u5b9f\u73fe\u3067\u304d\u308b\u6700\u9ad8\u306e\u9078\u629e\u80a2\u3067\u3059\u3002MXT\u30ab\u30e9\u30e0\u306e\u5b9f\u529b\u304c\u3069\u306e\u3088\u3046\u306b\u767a\u63ee\u3055\u308c\u308b\u306e\u304b\u3001\u88fd\u54c1\u60c5\u5831\u3084\u95a2\u9023\u8cc7\u6599\u3067\u305c\u3072\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>\u30d1\u30ea\u7b2c12\u5927\u5b66\u306eLISA\uff08Laboratoire Interuniversitaire des Syst\u00e8mes Atmosph\u00e9riques\uff09\u3067\u5b87\u5b99GC\u30c1\u30fc\u30e0\u306e\u8cac\u4efb\u8005\u3067\u3042\u3063\u305fRobert Sternberg\u6c0f\u306f\u3001\u30ed\u30bc\u30c3\u30bf\u30df\u30c3\u30b7\u30e7\u30f3\u3067\u4f7f\u7528\u3055\u308c\u305fMXT\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u6b21\u306e\u3088\u3046\u306b\u8ff0\u3079\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u5b87\u5b99\u30df\u30c3\u30b7\u30e7\u30f3\u7528\u306b\u63a1\u7528\u3055\u308c\u305f\u30ab\u30e9\u30e0\u306f\u3059\u3079\u3066\u3001\u632f\u52d5\u3001\u653e\u5c04\u7dda\u3001\u71b1\u30b5\u30a4\u30af\u30eb1\u306a\u3069\u306e\u5b87\u5b99\u9069\u683c\u6027\u8a66\u9a13\u306b\u5408\u683c\u3057\u3066\u304a\u308a\u3001\u5b87\u5b99\u3067\u306e\u4f7f\u7528\u306b\u8010\u3048\u308b\u5805\u7262\u6027\u304c\u5b9f\u8a3c\u3055\u308c\u307e\u3057\u305f\u3002<br><br>Restek\u306f\u3001\u5358\u306a\u308bLISA\u3078\u306e\u30ab\u30e9\u30e0\u4f9b\u7d66\u30e1\u30fc\u30ab\u30fc\u306b\u3068\u3069\u307e\u3089\u305a\u3001\u6700\u521d\u304b\u3089\u91cd\u8981\u306a\u30d1\u30fc\u30c8\u30ca\u30fc\u3067\u3057\u305f\u3002LISA\u306e\u6c42\u3081\u308b\u72ec\u81ea\u306e\u79d1\u5b66\u7684\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001Restek\u306f\u30ab\u30b9\u30bf\u30e0\u30e1\u30a4\u30c9\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30ab\u30e9\u30e0\u306e\u958b\u767a\u306b\u304a\u3044\u3066\u3001LISA\u3068\u7dca\u5bc6\u306b\u9023\u643a\u3057\u3001\u591a\u5927\u306a\u652f\u63f4\u3092\u884c\u3063\u3066\u304d\u3066\u304f\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u305f\u3081\u3001LISA\u306f\u5b87\u5b99\u7528\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30ab\u30e9\u30e0\u306e\u7814\u7a76\u958b\u767a\u304cRestek\u306e\u5354\u529b\u306a\u3057\u306b\u306f\u6210\u3057\u5f97\u306a\u304b\u3063\u305f\u3068\u8003\u3048\u3066\u304a\u308a\u3001\u7406\u60f3\u7684\u306a\u30d1\u30fc\u30c8\u30ca\u30fc\u3067\u3042\u308bRestek\u306b\u6df1\u304f\u611f\u8b1d\u3057\u3066\u3044\u307e\u3059\u3002\u300d<\/p>\n<\/blockquote>\n\n\n\n<ol class=\"wp-block-list\">\n<li>C. Szopa, U.J. Meierhenrich, D. Coscia, L. Janin, F. Goesmann, R. Sternberg, J.-F. Brun, G. Israel, M. Cabane, R. Roll, F. Raulin, W. Thiemann, C. Vidal-Madjar, H. Rosenbauer, Gas chromatography for in situ analysis of a cometary nucleus IV. Study of capillary column robustness for space application, J. Chromatogr. A, 982 (2002) 303-312.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ab\u30b9\u30bf\u30e0\u30b5\u30a4\u30ba\u3082\u67d4\u8edf\u306b\u5bfe\u5fdc\u53ef\u80fd\u306aGC\u30e1\u30bf\u30eb\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">MXT\u30ab\u30e9\u30e0\u306f\u304a\u5ba2\u69d8\u306e\u30cb\u30fc\u30ba\u306b\u5408\u308f\u305b\u305f\u30b5\u30a4\u30ba\u30aa\u30fc\u30c0\u30fc\u304c\u53ef\u80fd\u3067\u3059\u3002\u30d7\u30ed\u30bb\u30b9GC\u3001\u30d9\u30f3\u30c1\u30c8\u30c3\u30d7GC\u306a\u3069\u3001\u7528\u9014\u306b\u5fdc\u3058\u3066\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u3054\u63d0\u6848\u3057\u307e\u3059\u3002\u5404\u88fd\u54c1\u30da\u30fc\u30b8\uff08WEB\uff09\u306b\u8a18\u8f09\u306e\u6a19\u6e96\u4ed5\u69d8\u306b\u52a0\u3048\u3001\u3055\u307e\u3056\u307e\u306a\u30ab\u30b9\u30bf\u30e0\u69cb\u6210\u3067\u306e\u3054\u6ce8\u6587\u306b\u3082\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u8a18\u8f09\u3057\u305f\u3088\u3046\u306a\u4ed5\u69d8\u306eMXT\u30ab\u30e9\u30e0\u3092\u3054\u6ce8\u6587\u306e\u969b\u306f\u3001\u305d\u306e\u30b5\u30d5\u30a3\u30c3\u30af\u30b9\uff08\u679d\u756a\uff09\u3092\u8ffd\u52a0\u3057\u305f\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u3092\u304a\u77e5\u3089\u305b\u304f\u3060\u3055\u3044\uff08\u4f8b\uff1aMXT-1\u30ab\u30e9\u30e0\u3001\u5185\u5f842.0\u30a4\u30f3\u30c1\u3001\u30b1\u30fc\u30b8\u306a\u3057\u306e\u5834\u5408\u306f\u30ab\u30bf\u30ed\u30b0\u756a\u53f771811-274\u3068\u306a\u308a\u307e\u3059\uff09\u3002\u30aa\u30f3\u30e9\u30a4\u30f3\u6ce8\u6587\u6642\u306f\u3001\u88fd\u54c1\u756a\u53f7\u3092\u5165\u529b\u3057\u305f\u5f8c\u3001\u7279\u5225\u6307\u793a\u6b04\u306b\u30b5\u30d5\u30a3\u30c3\u30af\u30b9\u3092\u5165\u529b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3054\u5e0c\u671b\u306e\u4ed5\u69d8\u304c\u898b\u3064\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">\u30ab\u30b9\u30bf\u30de\u30fc\u30b5\u30fc\u30d3\u30b9<\/a>\u307e\u3067\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fbMXT PLOT\u30ab\u30e9\u30e0\u306f\u6a19\u6e96\u30b3\u30a4\u30eb\u76f4\u5f847\u30a4\u30f3\u30c1\u300111\u30d4\u30f3\u30b1\u30fc\u30b8\u3001\u304a\u3088\u3073\u300c-273\u300d\u69cb\u6210\u306e\u307f\u5bfe\u5fdc\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fb\u5916\u5f84\uff08OD\uff09\u306f\u6982\u7b97\u5024\u3067\u3001\u30c1\u30e5\u30fc\u30d6\u5185\u5f84\u3084\u30ab\u30e9\u30e0\u9577\u306b\u3088\u308a\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th><strong>\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u30b5\u30d5\u30a3\u30c3\u30af\u30b9<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>MXT\u30b3\u30a4\u30eb\u4ed5\u69d8<\/strong><\/th><\/tr><\/thead><tbody><tr><td>-274<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.0&#8243; ID without cage<\/td><\/tr><tr><td>-2740<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.0&#8243; ID banded with copper wire<\/td><\/tr><tr><td>-273<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.75&#8243; ID\/3.5&#8243; OD without cage (fits SRI GCs)<\/td><\/tr><tr><td>-2730<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.75&#8243; ID\/3.5&#8243; OD banded with copper wire (fits SRI GCs)<\/td><\/tr><tr><td>-2731<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.75&#8243; ID\/3.5&#8243; OD without cage, 18&#8243; leads (fits SRI GCs)<\/td><\/tr><tr><td>-2732<\/td><td class=\"has-text-align-left\" data-align=\"left\">2.75\u201d ID\/3.5\u201d OD without cage, 9\u201d leads (fits SRI GCs)<\/td><\/tr><tr><td>-283<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.5&#8243; ID\/4.0&#8243; OD without cage<\/td><\/tr><tr><td>-2830<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.5&#8243; ID\/4.0&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-2831<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.5\u201d ID\/4.0\u201d OD without cage, 18\u201d leads (fits SRI GCs)<\/td><\/tr><tr><td>-272<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.5&#8243; ID\/5.0&#8243; OD without cage<\/td><\/tr><tr><td>-2720<\/td><td class=\"has-text-align-left\" data-align=\"left\">4.5&#8243; ID\/5.0&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-6850M<\/td><td class=\"has-text-align-left\" data-align=\"left\">5.0&#8243; ID\/5.25&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-271<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0&#8243; ID\/6.5&#8243; OD without cage<\/td><\/tr><tr><td>-2710<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0&#8243; ID\/6.5&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-276<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0&#8243; ID\/6.25&#8243; OD without cage<\/td><\/tr><tr><td>-2760<\/td><td class=\"has-text-align-left\" data-align=\"left\">6.0&#8243; ID\/6.25&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-277<\/td><td class=\"has-text-align-left\" data-align=\"left\">7.0&#8243; ID\/7.25&#8243; OD without cage<\/td><\/tr><tr><td>-2770<\/td><td class=\"has-text-align-left\" data-align=\"left\">7.0&#8243; ID\/7.25&#8243; OD banded with copper wire<\/td><\/tr><tr><td>-LUC18<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.18 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*<\/td><\/tr><tr><td>-LUC25<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.25 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*<\/td><\/tr><tr><td>-LUC53<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.53 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fbMXT\u30ea\u30fc\u30c9\u7dda\u306f\u7279\u306b\u8a18\u8f09\u304c\u306a\u3044\u9650\u308a36\u30a4\u30f3\u30c1\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*Lucidity miniGC\u7528MXT\u30ab\u30e9\u30e0\u306f30m\u4ee5\u4e0b\u3068\u306a\u308a\u307e\u3059\u3002\u3059\u3079\u3066\u3001\u5de5\u5834\u51fa\u8377\u6642\u306b\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u63a5\u7d9a\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u8ffd\u52a0\u8cbb\u7528\u304c\u304b\u304b\u308a\u307e\u3059\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u5e0c\u671b\u306e\u30ab\u30e9\u30e0\u304c\u898b\u3064\u304b\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u30ab\u30b9\u30bf\u30e0\u5bfe\u5fdc\u3082\u53ef\u80fd\u3067\u3059\u306e\u3067<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">\u30ab\u30b9\u30bf\u30de\u30fc\u30b5\u30fc\u30d3\u30b9<\/a>\u307e\u3067\u30e1\u30fc\u30eb\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">\u5b89\u5b9a\u3057\u305fMXT\u30ab\u30e9\u30e0\u63a5\u7d9a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">MXT\u30ab\u30e9\u30e0\u540c\u69d8\u3001\u5805\u7262\u306a<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20394\" target=\"_blank\" rel=\"noreferrer noopener\">MXT\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30b3\u30cd\u30af\u30bf<\/a>\u3082Siltek\u51e6\u7406\u306b\u3088\u308a\u6d3b\u6027\u5316\u5408\u7269\u306b\u5bfe\u3059\u308b\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002430\u2103\u307e\u3067\u306e\u9ad8\u6e29\u4e0b\u3067\u3082\u4e0d\u6d3b\u6027\u5c64\u306e\u52a3\u5316\u306a\u304f\u4f7f\u7528\u3067\u304d\u3001\u71b1\u8cea\u91cf\u304c\u4f4e\u3044\u305f\u3081\u6025\u6fc0\u306a\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3082\u5bfe\u5fdc\u3057\u307e\u3059\u3002\u5185\u5f840.28mm\u30010.32mm\u30010.53mm\u306e\u30ab\u30e9\u30e0\u306b\u95a2\u3057\u3066\u3001\u6a19\u6e96\u63a5\u7d9a\u306e\u307b\u304b\u3001\u300cY\u300d\u69cb\u6210\uff082\u672c\u306e\u30ab\u30e9\u30e0\u30921\u3064\u306e\u6ce8\u5165\u53e3\u306b\u63a5\u7d9a\u3001\u307e\u305f\u306f1\u672c\u306e\u30ab\u30e9\u30e0\u30922\u3064\u306e\u691c\u51fa\u5668\u306b\u63a5\u7d9a\uff09\u306b\u3082\u5bfe\u5fdc\u3059\u308b\u30ad\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u5805\u7262\u3067\u4e0d\u6d3b\u6027\u306aMXT\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30b3\u30cd\u30af\u30bf\u306b\u3088\u308a\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3084\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u3082\u5b89\u5fc3\u3057\u3066\u8a2d\u7f6e\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u5b8c\u5168\u6027\u3092\u7dad\u6301\u3059\u308b\u4e0d\u6d3b\u6027\u306a\u30d5\u30ed\u30fc\u304c\u5b9f\u73fe\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"490\" height=\"445\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1368D-01.png\" alt=\"\" class=\"wp-image-22965\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1368D-01.png 490w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1368D-01-300x272.png 300w\" sizes=\"auto, (max-width: 490px) 100vw, 490px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_384360-01{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_384360-01 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_384360-01 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_384360-01 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_384360-01\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_44fa8e-4e.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_44fa8e-4e.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_44fa8e-4e.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_44fa8e-4e.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_44fa8e-4e kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/c\/1182\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">MXT<br>\u30ab\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_9f302b-35{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_9f302b-35 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_9f302b-35 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_9f302b-35 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_9f302b-35\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_09b4f5-52.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_09b4f5-52.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_09b4f5-52.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_09b4f5-52.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_09b4f5-52 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/ja\/?s=mxt\"><span class=\"kt-btn-inner-text\">MXT<br>\u95a2\u9023\u6587\u732e\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43801_88992d-9f{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43801_88992d-9f .kt-button{font-weight:normal;font-style:normal;}.kt-btns43801_88992d-9f .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43801_88992d-9f .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43801_88992d-9f\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43801_0b67a7-2c.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43801_0b67a7-2c.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43801_0b67a7-2c.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43801_0b67a7-2c.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43801_0b67a7-2c kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/chromatogram-library\/?s=mxt\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">MXT<br>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u9ad8\u6e29\u74b0\u5883\u4e0b\u3067\u3082\u5b89\u5b9a\u7a3c\u50cd\u3059\u308b\u5805\u7262\u306aMXT\u91d1\u5c5e\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306e\u4e0d\u6d3b\u6027\u51e6\u7406\u3067\u6b63\u78ba\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3002\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u73fe\u5834\u3084\u30d7\u30ed\u30bb\u30b9\u5206\u6790\u3001\u5c0f\u578bGC\u306b\u3082\u6700\u9069\u3002\u30ab\u30b9\u30bf\u30e0\u30b5\u30a4\u30ba\u3084\u591a\u69d8\u306a\u7528\u9014\u306b\u67d4\u8edf\u5bfe\u5fdc\u3057\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u53d6\u5f97\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":26889,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-43801","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/header-brand-story-GNSS1368C-1024x485.jpg",1024,485,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43801"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43801\/revisions"}],"predecessor-version":[{"id":83712,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43801\/revisions\/83712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/26889"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43801"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43801"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43801"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43801"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43801"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43801"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43801"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43801"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}