{"id":43806,"date":"2026-08-31T19:22:22","date_gmt":"2026-08-31T19:22:22","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-10-critical-steps-to-world-class-reference-standards\/"},"modified":"2026-03-06T04:58:18","modified_gmt":"2026-03-06T04:58:18","slug":"japanese-10-critical-steps-to-world-class-reference-standards","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss1556-ja\/japanese-10-critical-steps-to-world-class-reference-standards","title":{"rendered":"\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306e\u54c1\u8cea\u4fdd\u8a3c\u3068\u306f\uff5c10\u306e\u91cd\u8981\u9805\u76ee\u3067\u6574\u7406"},"content":{"rendered":"\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001Restek\u306e\u6a19\u6e96\u7269\u8cea\u304c\u4e16\u754c\u6c34\u6e96\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3067\u3042\u308b\u7406\u7531\u3092\u300110\u306e\u30b9\u30c6\u30c3\u30d7\u3067\u89e3\u8aac\u3057\u307e\u3059\u3002CRM\u306e\u57fa\u672c\u304b\u3089\u3001\u5206\u6790\u7cbe\u5ea6\u3092\u9ad8\u3081\u308b\u30dd\u30a4\u30f3\u30c8\u307e\u3067\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:20px\">\u25c6\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea(CRM)\u3068\u306f?\uff1aISO\/IEC 17025 &amp; ISO 17034\u306b\u57fa\u3065\u304f\u5b9a\u7fa9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08Certified Reference Material\uff0fCRM\uff09\u306f\u3001\u4e00\u822c\u7684\u306b\u306f\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u3082\u547c\u3070\u308c\u3001\u53c2\u7167\u57fa\u6e96\u3084\u6a19\u6e96\u7269\u8cea\u3092\u610f\u5473\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002Restek\u306eCRM\u306f\u3001ISO17034\u53ca\u3073ISO\/IEC17025\u306b\u57fa\u3065\u304f\u53b3\u683c\u306a\u8981\u4ef6\u3092\u6e80\u305f\u3057\u305f\u3001CRM\u306e\u4e2d\u3067\u3082\u7279\u306b\u53b3\u5bc6\u306b\u5b9a\u7fa9\u3055\u308c\u305f\u30b5\u30d6\u30bb\u30c3\u30c8\u3067\u3059:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\"><\/p>\n\n\n\n<ul style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\" class=\"wp-block-list\">\n<li>\u9069\u683c\u306a\u6a5f\u5668\u306e\u9069\u683c\u306a\u65b9\u6cd5\u3067\u7279\u6027\u304c\u6c7a\u5b9a\u3055\u308c\u305f\u539f\u6750\u6599\u3092\u4f7f\u7528<\/li>\n\n\n\n<li>\u6587\u66f8\u5316\u3055\u308c\u305f\u624b\u9806\u306b\u57fa\u3065\u304d\u3001ISO\u8a8d\u5b9a\u65bd\u8a2d\u3067\u88fd\u9020<\/li>\n\n\n\n<li>\u88fd\u9020\u8005\u306e\u8a8d\u5b9a\u7bc4\u56f2\u5185\u306b\u8a72\u5f53<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u8a8d\u5b9a\u306fILAC MRA\u7f72\u540d\u6a5f\u95a2\u3067\u3042\u308bA2LA\u306b\u3088\u308a\u4ed8\u4e0e\u3055\u308c\u3066\u304a\u308a\u3001Restek\u306e\u8a3c\u660e\u66f8\u306f\u56fd\u969b\u7684\u306b\u627f\u8a8d\u30fb\u53d7\u3051\u5165\u308c\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u3001Restek\u306eCRM\u306f\u3001ISO\u306b\u6e96\u62e0\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001ILAC MRA\u3092\u901a\u3058\u3066\u4e16\u754c\u4e2d\u306e\u898f\u5236\u5f53\u5c40\u3084\u8a66\u9a13\u6240\u3067\u901a\u7528\u3059\u308b\u201c\u771f\u6b63\u306aCRM\u201d\u3067\u3059\u3002<br>Restek\u306eISO\u54c1\u8cea\u8a8d\u8a3c\u306b\u3064\u3044\u3066\u306e\u8a73\u7d30\u304a\u3088\u3073\u8a8d\u8a3c(\u8a8d\u5b9a\u7bc4\u56f2\u3092\u542b\u307f\u307e\u3059) \u306f<a href=\"https:\/\/discover.restek.com\/iso-quality-credentials\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/iso-quality-credentials\/\" rel=\"noreferrer noopener\">www.restek.com\/ iso<\/a>&nbsp;\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:20px\">\u25c6\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3067\u3042\u308b\u305f\u3081\u306e10\u306e\u91cd\u8981\u30b9\u30c6\u30c3\u30d7<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:18px\">1. \u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\u958b\u767a\u306e\u51fa\u767a\u70b9\uff1a\u9867\u5ba2\u30cb\u30fc\u30ba\u3068\u516c\u5b9a\u6cd5\u30ec\u30d3\u30e5\u30fc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0\">\u3069\u306e\u3088\u3046\u306a\u6709\u6a5f\u6a19\u6e96\u7269\u8cea\u3092\u88fd\u54c1\u3068\u3057\u3066\u958b\u767a\u3059\u3079\u304d\u304b\u3092\u6c7a\u3081\u308b\u305f\u3081\u306b\u3001Restek\u306e\u5c02\u9580\u5bb6\u306f\u4e16\u754c\u4e2d\u306e\u653f\u5e9c\u306e\u898f\u5236\u3084\u516c\u5b9a\u6cd5\u306b\u914d\u616e\u3057\u3001\u304a\u5ba2\u3055\u307e\u3084\u8ca9\u58f2\u4ee3\u7406\u5e97\u3068\u7a4d\u6975\u7684\u306b\u95a2\u308f\u308a\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u898f\u5236\u306e\u5909\u66f4\u3084\u304a\u5ba2\u3055\u307e\u306e\u30cb\u30fc\u30ba\u3001\u5f53\u793e\u306e25\u5e74\u4ee5\u4e0a\u306e\u7d4c\u9a13\u306b\u57fa\u3065\u3044\u3066\u88fd\u54c1\u304c\u6c7a\u307e\u308b\u3068\u3001\u7d4c\u9a13\u8c4a\u304b\u306aRestek\u306e\u5316\u5b66\u8005\u306f\u9069\u5207\u306a\u5316\u5408\u7269\u306e\u7d44\u5408\u305b\u3068\u6fc3\u5ea6\u3067\u69cb\u6210\u3055\u308c\u305f\u5b89\u5b9a\u3057\u305f\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3092\u63d0\u6848\u3057\u307e\u3059\u3002\u6b21\u3044\u3067\u3001\u5168\u3066\u306e\u51e6\u65b9\u306f\u5225\u306e\u5316\u5b66\u8005\u306b\u3088\u3063\u3066\u7cbe\u5ea6\u3001\u9069\u5408\u6027\u304a\u3088\u3073\u6eb6\u89e3\u6027\u306e\u5fb9\u5e95\u7684\u306a\u898b\u76f4\u3057\u3092\u53d7\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">2. ISO 17034\u306b\u6e96\u62e0\u3057\u305f\u4fe1\u983c\u6027\u78ba\u4fdd\uff1a\u9069\u5408\u6027\u30fb\u5b89\u5b9a\u6027\u306e\u691c\u8a3c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u4f7f\u7528\u3055\u308c\u308b\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u306f\u3001\u53b3\u3057\u3044\u7d14\u5ea6\u57fa\u6e96\u306b\u4fdd\u305f\u308c\u3001\u51e6\u65b9\u304a\u3088\u3073\u898b\u76f4\u3057\u306e\u4e21\u65b9\u3067\u5316\u5408\u7269\u306e\u9069\u5408\u6027\u304c\u7cbe\u67fb\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u4fe1\u983c\u3042\u308b\u6b63\u78ba\u306a\u6709\u52b9\u671f\u9650\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u3001ISO 17034\u304a\u3088\u3073ISO\u30ac\u30a4\u30c935\u306b\u5f93\u3063\u305f\u3001\u9577\u671f\u5b89\u5b9a\u6027\u8a66\u9a13\u3068\u77ed\u671f\u51fa\u8377\u5b89\u5b9a\u6027\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">3. \u539f\u6750\u6599\u306e\u5fb9\u5e95\u3057\u305f\u7279\u6027\u4ed8\u3051\uff1aGC-MS\u3084LC-MS\u306b\u3088\u308b\u30de\u30eb\u30c1\u624b\u6cd5\u5206\u6790<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">Restek\u306e\u54c1\u8cea\u7ba1\u7406\u90e8\u9580\uff08QC\uff09\u3067\u306f\u3001GC-FID\u3001HPLC\u3001GC-ECD\u3001GC-MS\u3001LC-MS\u3001\u5c48\u6298\u7387\u6e2c\u5b9a\u304a\u3088\u3073\u878d\u70b9\u6e2c\u5b9a\u306e\u3046\u3061\u30012\u3064\u4ee5\u4e0a\u306e\u624b\u6cd5\u3067\u3001\u6df7\u5408\u6210\u5206\u3068\u6eb6\u5a92\u306e\u5316\u5b66\u7269\u8cea\u306e\u7279\u6027\u3068\u7d14\u5ea6\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0;font-size:18px\">4. NIST\u30c8\u30ec\u30fc\u30b5\u30d6\u30eb\u57fa\u6e96\u306b\u3088\u308b\u7cbe\u5ea6\u4fdd\u8a3c\uff1a\u5206\u6790\u5929\u3073\u3093\u306e\u6821\u6b63<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0\">\u3059\u3079\u3066\u306e\u5206\u6790\u5929\u3073\u3093\u306f\u3001NIST *\u30c8\u30ec\u30fc\u30b5\u30d6\u30eb\u306a\u5206\u9285\u3092\u7528\u3044\u3066\u6bce\u65e57\u3064\u306e\u8cea\u91cf\u30ec\u30d9\u30eb\u3067\u691c\u8a3c\u3055\u308c\u3001\u6b63\u78ba\u306a\u6e2c\u5b9a\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u306bISO\/IEC 17025\u8a8d\u5b9a\u4e8b\u696d\u8005\u306b\u3088\u3063\u3066\u6bce\u5e74\u6821\u6b63\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br>* National Institute of Standards and Technology<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">5. \u6a19\u6e96\u8a66\u85ac\u306e\u5b89\u5b9a\u6027\u7dad\u6301\uff1a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u305f\u30ac\u30e9\u30b9\u5668\u5177\u3068\u30a2\u30f3\u30d7\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">Restek\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306f\u3001Class A(\u9ad8\u4f4d\u898f\u683c)\u306e\u30e1\u30b9\u30d5\u30e9\u30b9\u30b3\u3084\u30d4\u30da\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u8abf\u88fd\u3055\u308c\u307e\u3059\u3002\u30a2\u30f3\u30d7\u30eb\u304a\u3088\u3073\u3001\u8abf\u88fd\u3068\u4fdd\u5b58\u306b\u7528\u3044\u308b\u30d0\u30a4\u30a2\u30eb\u306f\u3001\u5206\u6790\u5bfe\u8c61\u7a2e\u306e\u640d\u5931\u3092\u9632\u3050\u305f\u3081\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright is-resized\" style=\"margin-top:0px;margin-right:0;margin-bottom:0px;margin-left:0\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1556E-01.jpg\" alt=\"logo, company name\" style=\"aspect-ratio:1.8019828155981494;width:220px\" title=\"-\"><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\" style=\"padding-top:0px;padding-bottom:0px;font-size:18px\">6. ISO\u8a8d\u5b9a\u65bd\u8a2d\u3067\u306e\u88fd\u9020\uff1aISO 17034 &amp; ISO\/IEC 17025 \u8a8d\u5b9a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\u30da\u30f3\u30b7\u30eb\u30d9\u30cb\u30a2\u5dde\u306b\u3042\u308bRestek\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u88fd\u9020\u65bd\u8a2d\u53ca\u3073QC\u30e9\u30dc\u306f\u3001ISO 17034\u304a\u3088\u3073ISO \/ IEC 17025\u306e\u8a8d\u5b9a\u3092\u53d6\u5f97\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u8a8d\u5b9a\u306f\u30011994\u5e74\u304b\u3089\u7d99\u7d9a\u3057\u3066\u3044\u308bISO 9001\u306b\u52a0\u3048\u3066\u3001\u56fd\u969b\u6a19\u6e96\u5316\u6a5f\u69cb(ISO)\u304c\u5b9a\u3081\u305f\u4e16\u754c\u30ec\u30d9\u30eb\u306e\u54c1\u8cea\u57fa\u6e96\u3092\u6e80\u305f\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<br>\u3053\u308c\u3089\u306eISO\u8a8d\u5b9a\u30e9\u30dc\u3067\u306f\u3001\u305d\u3053\u3067\u306e\u751f\u7523\u3001\u539f\u6750\u6599\u5206\u6790\u3001\u5b9a\u6027\u3001\u304a\u3088\u3073\u5b9a\u91cf\u5206\u6790\u3092\u5168\u3066\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Restek\u306eISO\u8a8d\u5b9a\u30e9\u30dc\u3067\u306f\u3001\u65e2\u88fd\u54c1\u3068\u30ab\u30b9\u30bf\u30e0\u54c1\u306e\u4e21\u65b9\u306eCRM\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002 \u8a73\u7d30\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/discover.restek.com\/iso-quality-credentials\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/iso-quality-credentials\/\">www.restek.com\/iso<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">7. \u5206\u6790\u8a3c\u660e\u66f8\u3068\u6587\u66f8\u63d0\u4f9b\uff1aCRM\u306e\u4fe1\u983c\u3092\u652f\u3048\u308b\u900f\u660e\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">Restek\u306f\u81ea\u793e\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u3001\u5b8c\u5168\u306bISO\u306b\u6e96\u62e0\u3057\u305f3\u3064\u306e\u30ec\u30d9\u30eb\u306e\u5206\u6790\u8a3c\u660e\u66f8\uff08Certificate of Analysis: CoA\/CofA\uff09\u3092\u7528\u610f\u3057\u3066\u304a\u308a\u3001\u307b\u3068\u3093\u3069\u306e\u65e2\u88fd\u54c1(\u30ab\u30bf\u30ed\u30b0\u54c1)\u306b\u306f\u3001\u5206\u6790\u8a3c\u660e\u66f8-\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fcPlus\u304c\u6dfb\u4ed8\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul style=\"margin-top:var(--wp--preset--spacing--30);margin-bottom:var(--wp--preset--spacing--30)\" class=\"wp-block-list\">\n<li><strong>\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Gravimetric\uff08\u91cd\u91cf\u8a18\u9332\uff09<\/strong>\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea (CRM) \u306b\u3064\u3044\u3066\u306f\u3001\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Chromatographic\uff08\u7d44\u6210\u78ba\u8a8d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4ed8\u304d\uff09<\/strong>\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001CRM\u306b\u3064\u3044\u3066\u306f\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002\u202f\u3055\u3089\u306b\u3001\u30d1\u30c3\u30b1\u30fc\u30b8\u30e6\u30cb\u30c3\u30c8\u304b\u30891\u3064\u3092\u629c\u304d\u53d6\u308a\u3001\u6df7\u5408\u7269\u306e\u7d44\u6210\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u9069\u5207\u306a\u624b\u6cd5\u3067\u30c6\u30b9\u30c8\u3057\u307e\u3059\u3002\u202f\u5404\u30d4\u30fc\u30af\u304c\u540c\u5b9a\u3055\u308c\u305f\u3053\u306e\u6a19\u6e96\u7269\u8cea\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Chromatographic Plus\uff08n=3\u30fb\u30ed\u30c3\u30c8\u9593\u7d71\u8a08\u6bd4\u8f03\u304c\u8ffd\u52a0\uff09<\/strong> \u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002CRM\u306b\u3064\u3044\u3066\u306f\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d1\u30c3\u30b1\u30fc\u30b8\u30e6\u30cb\u30c3\u30c8\u306e\u3046\u30611\u3064\u306fn=3\u3067\u5206\u6790\u3055\u308c\u3001\u305d\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u5024\u306f\u7d71\u8a08\u7684\u306b\u5225\u30ed\u30c3\u30c8\u3068\u6bd4\u8f03\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5225\u30ed\u30c3\u30c8\u306f\u3001\u305d\u306e\u524d\u306e\u30ed\u30c3\u30c8\u304c\u3042\u308b\u5834\u5408\u306f\u524d\u306e\u30ed\u30c3\u30c8\u3001\u307e\u305f\u306f\u65b0\u3057\u304f\u751f\u7523\u3055\u308c\u305f\u72ec\u7acb\u3057\u305f2\u756a\u76ee\u306e\u30ed\u30c3\u30c8\u3068\u306a\u308a\u307e\u3059\u3002\u202f\u5404\u30d4\u30fc\u30af\u304c\u540c\u5b9a\u3055\u308c\u305f\u3053\u306e\u6a19\u6e96\u7269\u8cea\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">Restek\u306e\u3059\u3079\u3066\u306e\u30ab\u30bf\u30ed\u30b0\u54c1\u304a\u3088\u3073\u30ab\u30b9\u30bf\u30e0\u54c1\u306e\u6a19\u6e96\u7269\u8cea\u306b\u95a2\u3059\u308b\u3001\u88fd\u54c1\u8a3c\u660e\u66f8\u3001\u5b9a\u91cf\u30a2\u30c3\u30bb\u30a4\u30c7\u30fc\u30bf\u3068\u7d71\u8a08\u5024\u3001\u6a19\u6e96\u7269\u8cea\u30d0\u30c3\u30c1\u30ec\u30b3\u30fc\u30c9\u3092\u542b\u3080\u8a73\u7d30\u306a\u30c7\u30fc\u30bf\u30d1\u30c3\u30af\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/documentation-search\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/documentation-search\" target=\"_blank\" rel=\"noopener\">www.restek.com\/documentation<\/a> \u304b\u3089\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">8. GHS\u6e96\u62e0\u30fbQR\u30b3\u30fc\u30c9\u3067\u8a3c\u660e\u66f8\u3078\u5373\u30a2\u30af\u30bb\u30b9\uff1a\u5305\u88c5\u3068\u30e9\u30d9\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u3059\u3079\u3066\u306eRestek\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306f\u3001\u51fa\u8377\u5f8c\u304b\u3089\u7d0d\u54c1\u307e\u3067\u306e\u9593\u306e\u88fd\u54c1\u3092\u78ba\u5b9f\u306b\u4fdd\u8b77\u3067\u304d\u308b\u3088\u3046\u306b\u3001\u53b3\u91cd\u306b\u68b1\u5305\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u88fd\u54c1\u30e9\u30d9\u30eb\u306f\u3001\u5b89\u5168\u6027\u3068GHS\u6e96\u62e0\u306e\u8a18\u8f09\u306b\u52a0\u3048\u3066\u3001\u5206\u304b\u308a\u3084\u3059\u3044\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u4fdd\u7ba1\u65b9\u6cd5\u3001\u5b89\u5168\u6027\u3001\u304a\u3088\u3073\u4fdd\u7ba1\u671f\u9650\u60c5\u5831\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306eRestek\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306f\u3001\u30b3\u30f3\u30d1\u30af\u30c8\u3067\u8010\u4e45\u6027\u306e\u3042\u308b\u74b0\u5883\u306b\u3084\u3055\u3057\u3044\u30d1\u30c3\u30b1\u30fc\u30b8\u306b\u5165\u308c\u3089\u308c\u3001\u51fa\u8377\u304b\u3089\u304a\u5c4a\u3051\u307e\u3067\u4fdd\u8b77\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ce\u30fc\u30c8\u3084\u30d0\u30a4\u30a2\u30eb\u306b\u8cbc\u308b\u30e9\u30d9\u30eb\u306f\u3001\u4fdd\u7ba1\u6761\u4ef6\u3084\u5b89\u5168\u6027\u3001\u4fdd\u7ba1\u671f\u9650\u306a\u3069\u306e\u91cd\u8981\u306a\u60c5\u5831\u3092\u8aad\u307f\u3084\u3059\u304f\u8868\u793a\u3057\u3001\u5b89\u5168\u6027\u3092\u9ad8\u3081\u308b\u3068\u3068\u3082\u306bGHS\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002\u30a2\u30f3\u30d7\u30eb\u4fdd\u7ba1\u7528\u30c1\u30e5\u30fc\u30d6\u306eQR\u30b3\u30fc\u30c9\u304b\u3089\u3001Restek.com\u306b\u3042\u308b\u3054\u4f7f\u7528\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u30ed\u30c3\u30c8\u756a\u53f7\u306e\u5206\u6790\u8a3c\u660e\u66f8\u306b\u3059\u3050\u306b\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059\u3002\u73fe\u884c\u306e\u30d1\u30c3\u30b1\u30fc\u30b8\u3068\u30e9\u30d9\u30eb\u306e\u6539\u5584\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/discover.restek.com\/articles\/gnss3975\/rethinking-your-reference-standards-experience\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss3975\/rethinking-your-reference-standards-experience\/\">www.restek.com\/Standards2022<\/a>&nbsp;\u3067\u8a73\u7d30\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">9. \u4ed8\u5c5e\u54c1\uff1a\u5b89\u5168\u3067\u4fbf\u5229\u306a\u30bb\u30fc\u30d5\u30af\u30e9\u30c3\u30ab\u30fc\u3068\u4e0d\u6d3b\u6027\u5316\u30d0\u30a4\u30a2\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">5mL\u672a\u6e80\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u306f\u79fb\u3057\u66ff\u3048\u7528\u306b\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u305f\u30b9\u30af\u30ea\u30e5\u30fc\u30d0\u30a4\u30a2\u30eb (cat.# 24640)\u304c\u4ed8\u5c5e\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3054\u6ce8\u6587\u6bce\u306b\u30a2\u30f3\u30d7\u30eb\u3092\u5b89\u5168\u306b\u6298\u308b\u3053\u3068\u304c\u3067\u304d\u308bRestek\u30bb\u30fc\u30d5\u30af\u30e9\u30c3\u30ab\u30fc\u304c\u4ed8\u3044\u3066\u304d\u307e\u3059\u3002(\u30bb\u30fc\u30d5\u30af\u30e9\u30c3\u30ab\u30fc\u306b\u3064\u3044\u3066\u306f\u8ca9\u58f2\u3055\u308c\u3066\u3044\u308b\u5730\u57df\u306b\u3088\u3063\u3066\u306f\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002Restek\u682a\u5f0f\u4f1a\u793e\u3078\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002)<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:18px\">10. \u5728\u5eab\u7ba1\u7406\uff1a4,200\u4ee5\u4e0a\u306e\u5316\u5408\u7269\u30681,500\u88fd\u54c1\u3092\u5e38\u6642\u4f9b\u7d66<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u5fc5\u8981\u306a\u6642\u306b\u88fd\u54c1\u3092\u3054\u63d0\u4f9b\u3067\u304d\u308b\u3088\u3046\u3001Restek\u306f1,500\u4ee5\u4e0a\u306e\u30ab\u30bf\u30ed\u30b0\u63b2\u8f09\u54c1\u3068\u3001\u6700\u3082\u4e00\u822c\u7684\u306a\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3092\u8907\u6570\u306e\u30ed\u30c3\u30c8\u3001\u3055\u3089\u306b4,200\u4ee5\u4e0a\u306e\u5316\u5408\u7269\u306e\u5728\u5eab\u3092\u7d99\u7d9a\u7684\u306b\u5206\u6790\u3057\u7ba1\u7406\u3092\u884c\u3063\u3066\u3044\u307e\u3059\u3002 \u671f\u9650\u5207\u308c\u307e\u305f\u306f\u671f\u9650\u5207\u308c\u306b\u8fd1\u3044\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3092\u8aa4\u3063\u3066\u7d0d\u54c1\u3059\u308b\u3053\u3068\u3092\u907f\u3051\u308b\u305f\u3081\u3001Restek\u3067\u306f\u6709\u52b9\u671f\u9650\u306e\u6570\u304b\u6708\u524d\u306b\u5728\u5eab\u304b\u3089\u64a4\u53bb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:20px\">\u25c6Restek\u306e\u30ab\u30b9\u30bf\u30e0\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff1a\u30aa\u30fc\u30c0\u30fc\u30e1\u30a4\u30c9\u5bfe\u5fdc<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u5206\u6790\u306b\u5fc5\u8981\u306a\u6a19\u6e96\u7269\u8cea\u306f\u3001\u7528\u9014\u3084\u898f\u5236\u8981\u4ef6\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u3002Restek\u3067\u306f\u3001\u3053\u3046\u3057\u305f\u591a\u69d8\u306a\u30cb\u30fc\u30ba\u306b\u5fdc\u3048\u308b\u305f\u3081\u3001\u30ab\u30b9\u30bf\u30e0\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff08\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea, CRM\uff09\u306e\u30aa\u30fc\u30c0\u30fc\u30e1\u30a4\u30c9\u5bfe\u5fdc\u3092\u884c\u3063\u3066\u3044\u307e\u3059\u3002<br>\u5316\u5408\u7269\u306e\u7d44\u307f\u5408\u308f\u305b\u3001\u6fc3\u5ea6\u3001\u6eb6\u5a92\u3001\u5bb9\u91cf\u306a\u3069\u3092\u81ea\u7531\u306b\u8a2d\u8a08\u3067\u304d\u308b\u305f\u3081\u3001\u7814\u7a76\u958b\u767a\u304b\u3089\u898f\u5236\u8a66\u9a13\u307e\u3067\u5e45\u5e83\u304f\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002\u3059\u3079\u3066\u306e\u51e6\u65b9\u306f\u7d4c\u9a13\u8c4a\u5bcc\u306a\u5316\u5b66\u8005\u306b\u3088\u3063\u3066\u63d0\u6848\u3055\u308c\u3001\u5225\u306e\u5316\u5b66\u8005\u306b\u3088\u308b\u53b3\u683c\u306a\u30ec\u30d3\u30e5\u30fc\u3068\u5b89\u5b9a\u6027\u306e\u691c\u8a3c\u3092\u7d4c\u3066\u78ba\u5b9a\u3055\u308c\u307e\u3059\u3002<br>\u3055\u3089\u306b\u3001Restek\u306fISO 17034\u304a\u3088\u3073ISO\/IEC 17025\u306b\u6e96\u62e0\u3057\u305f\u88fd\u9020\u4f53\u5236\u3092\u6574\u3048\u3066\u304a\u308a\u3001ILAC MRA\u7f72\u540d\u6a5f\u95a2\u306e\u8a8d\u5b9a\u3092\u53d7\u3051\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30ab\u30b9\u30bf\u30e0\u54c1\u3067\u3082\u56fd\u969b\u7684\u306b\u901a\u7528\u3059\u308b\u54c1\u8cea\u57fa\u6e96\u3092\u6e80\u305f\u3057\u305f\u4fe1\u983c\u6027\u306e\u9ad8\u3044CRM\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u52a0\u3048\u3066\u3001\u88fd\u54c1\u8a3c\u660e\u66f8\u3001\u5b9a\u91cf\u30a2\u30c3\u30bb\u30a4\u30c7\u30fc\u30bf\u3001\u7d71\u8a08\u5024\u3001\u6a19\u6e96\u7269\u8cea\u30d0\u30c3\u30c1\u30ec\u30b3\u30fc\u30c9\u3092\u542b\u3080<strong>\u8a73\u7d30\u306a\u30c7\u30fc\u30bf\u30d1\u30c3\u30af<\/strong>\u3082\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u3001\u54c1\u8cea\u4fdd\u8a3c\u3084\u898f\u5236\u5bfe\u5fdc\u306b\u304a\u3051\u308b\u88cf\u4ed8\u3051\u3068\u3057\u3066\u5b89\u5fc3\u3057\u3066\u3054\u5229\u7528\u3044\u305f\u3060\u3051\u307e\u3059\u3002<br><br><strong>\u30ab\u30b9\u30bf\u30e0\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u898b\u7a4d\u308a\u4f9d\u983c\u306f<a href=\"https:\/\/discover.restek.com\/ja\/custom-product-request-forms-jp\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/custom-product-request-forms-jp\/\">www.restek.com\/solutions<\/a>\u306b\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1102\" target=\"_blank\" rel=\"noopener\">www.restek.com\/standards <\/a>\u304b\u3089\u3054\u53c2\u7167\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:20px\">\u25c6\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u304a\u3051\u308bPrimary\u3068Secondary \uff1aTNI\u30fbDoD\u8981\u4ef6\u3068Restek\u306e\u5bfe\u5fdc\u529b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">ISO\u898f\u683c\u306b\u57fa\u3065\u304f\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea (CRM) \u306e\u4f7f\u7528\u306f\u56fd\u969b\u7684\u306b\u6c42\u3081\u3089\u308c\u308b\u57fa\u672c\u8981\u4ef6\u3067\u3059\u304c\u3001\u7c73\u56fd\u3067\u306f\u3055\u3089\u306b\u8ffd\u52a0\u306e\u898f\u5236\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4ee3\u8868\u7684\u306a\u3082\u306e\u304c\u3001<strong>TNI\uff08The NELAC Institute\uff09\u304a\u3088\u3073DoD\uff08\u7c73\u56fd\u56fd\u9632\u7dcf\u7701\uff09QSM<\/strong>\u306e\u898f\u5b9a\u3067\u3059\u3002<\/p>\n\n\n\n<ul style=\"margin-top:var(--wp--preset--spacing--20);margin-bottom:var(--wp--preset--spacing--20)\" class=\"wp-block-list\">\n<li><strong>TNI (V1M4 4.1.7.1.1)<\/strong><br>\u521d\u671f\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u3001\u5225\u30e1\u30fc\u30ab\u30fc\u88fd\u3001\u307e\u305f\u306f\u540c\u4e00\u30e1\u30fc\u30ab\u30fc\u3067\u3082\u72ec\u7acb\u3057\u305f\u30ed\u30c3\u30c8\u3067\u8abf\u88fd\u3055\u308c\u305f\u6a19\u6e96\u3067\u691c\u8a3c\u3059\u308b\u3053\u3068\u3092\u8981\u6c42\u3002<\/li>\n\n\n\n<li><strong>DoD QSM 5.3 (2019, V1M4)<\/strong><br>\u521d\u671f\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u539f\u5247\u3068\u3057\u3066\u5225\u30e1\u30fc\u30ab\u30fc\u88fd\u306e\u6a19\u6e96\u3067\u691c\u8a3c\u3059\u308b\u3053\u3068\u3092\u6c42\u3081\u3066\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u540c\u4e00\u30e1\u30fc\u30ab\u30fc\u88fd\u3067\u3042\u3063\u3066\u3082\u3001\u7570\u306a\u308b\u539f\u6599\u30bd\u30fc\u30b9\u3084\u72ec\u7acb\u3057\u305f\u5de5\u7a0b\u3067\u8abf\u88fd\u3055\u308c\u305f\u5225\u30ed\u30c3\u30c8\u3067\u3042\u308c\u3070\u201cSecondary source\u201d\u3068\u3057\u3066\u8a8d\u3081\u3089\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u3053\u306e\u3088\u3046\u306b\u3001\u7c73\u56fd\u306e\u898f\u5236\u3067\u306f\u300cPrimary source\uff08\u4e00\u6b21\u30bd\u30fc\u30b9\uff09\u300d\u306b\u52a0\u3048\u3066\u300cSecondary source\uff08\u4e8c\u6b21\u30bd\u30fc\u30b9\uff09\u300d\u3092\u7528\u3044\u305f\u30af\u30ed\u30b9\u30c1\u30a7\u30c3\u30af\u304c\u7fa9\u52d9\u3065\u3051\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eCRM\u306f\u3001ISO\u306b\u6e96\u62e0\u3057\u305f\u4fe1\u983c\u6027\u306b\u3088\u308a\u4e00\u6b21\u30bd\u30fc\u30b9\u3068\u3057\u3066\u5229\u7528\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u306f\u3082\u3061\u308d\u3093\u3001\u540c\u4e00\u88fd\u54c1\u3067\u3082\u72ec\u7acb\u3057\u305f\u5225\u30ed\u30c3\u30c8\u3092\u3054\u63d0\u4f9b\u3067\u304d\u308b\u305f\u3081\u3001\u4e8c\u6b21\u30bd\u30fc\u30b9\u8981\u4ef6\u306b\u3082\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30e9\u30dc\u306fISO\u898f\u683c\u306b\u52a0\u3048\u3001TNI\u3084DoD\u304c\u6c42\u3081\u308b\u8ffd\u52a0\u8981\u4ef6\u3092Restek\u3060\u3051\u3067\u5b8c\u7d50\u3067\u304d\u307e\u3059\u3002<br>Restek\u306f\u30d7\u30e9\u30a4\u30de\u30ea\u30bd\u30fc\u30b9\u3068\u3057\u3066\u3082\u3001\u30bb\u30ab\u30f3\u30c0\u30ea\u30bd\u30fc\u30b9\u3068\u3057\u3066\u3082\u5229\u7528\u53ef\u80fd\u306aCRM\u3092\u5e45\u5e83\u304f\u63d0\u4f9b\u3067\u304d\u308b\u305f\u3081\u3001ISO\u898f\u683c\u3068\u3068\u3082\u306bTNI\u3084DoD\u306e\u8ffd\u52a0\u8981\u4ef6\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u307e\u3059\u3002\u52a0\u3048\u3066\u3001GC\u30fbLC\u30ab\u30e9\u30e0\u3084\u524d\u51e6\u7406\u88fd\u54c1\u3001\u30a2\u30af\u30bb\u30b5\u30ea\u3082\u63c3\u3046\u306e\u3067\u3001\u5206\u6790\u306b\u5fc5\u8981\u306a\u3059\u3079\u3066\u3092\u30ef\u30f3\u30b9\u30c8\u30c3\u30d7\u3067\u3054\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-top:0;margin-bottom:0;font-size:20px\">\u307e\u3068\u3081\uff1a\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3068\u6a19\u6e96\u8a66\u85ac\u306e\u54c1\u8cea\u78ba\u4fdd\u306b\u5411\u3051\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u672c\u8a18\u4e8b\u3067\u306f\u3001ISO 17034\u30fbISO\/IEC 17025 (ILAC MRA)&nbsp;\u306b\u6e96\u62e0\u3057\u305f\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3068\u6a19\u6e96\u8a66\u85ac\u3092\u9078\u5b9a\u30fb\u5229\u7528\u3059\u308b\u305f\u3081\u306e10\u306e\u91cd\u8981\u30b9\u30c6\u30c3\u30d7\u3092\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002 Restek\u306f\u3001\u4e16\u754c\u57fa\u6e96\u306e\u54c1\u8cea\u7ba1\u7406\u30fb\u5b89\u5b9a\u6027\u691c\u8a3c\u30fb\u900f\u660e\u306a\u6587\u66f8\u63d0\u4f9b\u3092\u901a\u3058\u3066\u3001\u74b0\u5883\u30fb\u98df\u54c1\u30fb\u533b\u85ac\u54c1\u306a\u3069\u591a\u69d8\u306a\u5206\u6790\u5206\u91ce\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002 \u9069\u5207\u306a\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\u3092\u7528\u3044\u308b\u3053\u3068\u306f\u3001\u5206\u6790\u306e\u7cbe\u5ea6\u3068\u4fe1\u983c\u6027\u3092\u9ad8\u3081\u308b\u6700\u3082\u78ba\u5b9f\u306a\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30804\">                                \u30ab\u30bf\u30ed\u30b0No. 30804                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u6c34\u9053\u6c34\u8cea\u57fa\u6e96\uff5cPFAS 3\u6210\u5206\u6df7\u5408\u6a19\u6e96\u6db2\uff5cPFOS PFOA PFHxS | \u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea, 10 \u00b5g\/mL, 1.2 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30804\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24640\">                                \u30ab\u30bf\u30ed\u30b0No. 24640                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Autosampler Vial Convenience Kit, Red PTFE\/Silicone Septa, 0.065&quot;, SilCote Deactivated, Amber w\/Black Cap, 2.0 mL, 8 mm, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24640\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4e16\u754c\u6c34\u6e96\u306e\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3092\u9078\u307610\u306e\u91cd\u8981\u30b9\u30c6\u30c3\u30d7\u3092\u5206\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3002\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3068\u306f\u4f55\u304b\u5206\u6790\u7cbe\u5ea6\u304c\u91cd\u8981\u306a\u5206\u6790\u8005\u5fc5\u8aad\u3002ISO 17034\u308417025, ILAC MRA\u3001SI\u30c8\u30ec\u30fc\u30b5\u30d6\u30eb\u5bfe\u5fdc\u3067\u4fe1\u983c\u6027\u3042\u308b\u5206\u6790\u3092\u5b9f\u73fe\u3002<\/p>\n","protected":false},"author":11,"featured_media":7333,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2560,2551,2579,2554],"resource-technique":[],"ppma_author":[2814,2814],"class_list":["post-43806","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-gas-standards-accessories-ja","product-library-air-gas-sampling-products-ja","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2560,"label":"\u30ac\u30b9\u6821\u6b63\u7528\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2551,"label":"\u5927\u6c17\uff5c\u30ac\u30b9 \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS1341-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43806","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43806"}],"version-history":[{"count":35,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43806\/revisions"}],"predecessor-version":[{"id":89597,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43806\/revisions\/89597"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7333"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43806"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43806"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43806"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43806"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43806"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43806"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43806"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43806"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43806"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}