{"id":43812,"date":"2020-12-17T00:00:00","date_gmt":"2020-12-17T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-raptor-lc-columns\/"},"modified":"2025-11-25T22:15:05","modified_gmt":"2025-11-25T22:15:05","slug":"japanese-raptor-lc-columns","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss1895-ja\/japanese-raptor-lc-columns","title":{"rendered":"Raptor LC \u30ab\u30e9\u30e0: \u9032\u5316\u3057\u305f\u9078\u629e\u6027"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_660ca4-76{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_660ca4-76 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_660ca4-76 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_660ca4-76 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_660ca4-76\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_2ab882-e5.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_2ab882-e5.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_2ab882-e5.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_2ab882-e5.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_2ab882-e5 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=raptor&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u88fd\u54c1\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_5b83c4-49{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_5b83c4-49 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_5b83c4-49 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_5b83c4-49 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_5b83c4-49\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_4d3777-05.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_4d3777-05.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_4d3777-05.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_4d3777-05.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_4d3777-05 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/ja\/?s=raptor&#038;sort=discover_searchable_posts_date_desc\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u306e\u8cc7\u6599\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_f588f2-e9{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_f588f2-e9 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_f588f2-e9 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_f588f2-e9 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_f588f2-e9\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_9e17ef-11.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_9e17ef-11.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_9e17ef-11.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_9e17ef-11.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_9e17ef-11 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/chromatogram-library\/?s=raptor\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u3088\u308a\u512a\u308c\u305f\u52b9\u7387\u304c\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3057\u307e\u3059\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u3088\u308a\u826f\u3044\u9078\u629e\u6027\u304c\u5206\u96e2\u80fd\u3092\u5927\u304d\u304f\u6539\u5584\u3057\u307e\u3059\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u65e2\u5b58\u306eHPLC\u3067\u3082UHPLC\u3067\u3082\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306f\u5897\u5927\u3057\u307e\u3059\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u518d\u73fe\u6027\u3092\u53ef\u80fd\u306b\u3059\u308b\u8010\u4e45\u6027\u306b\u512a\u308c\u305f\u5805\u7262\u306a\u30ab\u30e9\u30e0\u3067\u3059\u3002<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u65b0\u305f\u306a\u6642\u4ee3\u306e\u5e55\u958b\u3051<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50(\u4e00\u822c\u306bSPP\u307e\u305f\u306f\u300c\u30b3\u30a2\u30b7\u30a7\u30eb\u300d\u7c92\u5b50\u3068\u547c\u3070\u308c\u308b)\u306e\u52b9\u7387\u306f\u3001\u3088\u308a\u4f4e\u3044\u80cc\u5727\u3067\u9ad8\u901f\u5206\u96e2\u3092\u3082\u305f\u3089\u3059\u3068\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5229\u70b9\u306b\u3088\u308a\u3001\u65e2\u5b58\u306eHPLC\u6a5f\u5668\u3067\u3082\u3088\u308a\u8fc5\u901f\u306a\u5206\u96e2\u3092\u5b9f\u73fe\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001Small-particle\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3067\u3042\u308bSPP\u306f\u3001\u5168\u591a\u5b54\u6027\u7c92\u5b50\u3068\u6bd4\u8f03\u3057\u3066UHPLC\u306e\u52b9\u7387\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 SPP\u7c92\u5b50\u306f\u3001\u56fa\u4f53\u306e\u4e0d\u900f\u904e\u6027\u30b3\u30a2\u3092\u30b7\u30ea\u30ab\u306e\u8584\u3044\u591a\u5b54\u8cea\u5c64\u3067\u8986\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u62e1\u6563\u7d4c\u8def\u304c\u6e1b\u5c11\u3057\u3001\u30d4\u30fc\u30af\u306e\u62e1\u6563\u304c\u6291\u3048\u3089\u308c\u307e\u3059\u3002 \u305d\u306e\u7d50\u679c\u3001\u985e\u4f3c\u30b5\u30a4\u30ba\u306e\u5f93\u6765\u306e\u5168\u591a\u5b54\u6027\u7c92\u5b50\u3088\u308a\u3082\u52b9\u7387\u306f\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3059\u3002\u30b3\u30a2\u30b7\u30a7\u30eb\u7c92\u5b50\u306fLC\u3092\u5909\u3048\u307e\u3057\u305f\u304c\u3001\u305d\u308c\u306f\u59cb\u307e\u308a\u306b\u904e\u304e\u307e\u305b\u3093\u30fb\u30fb\u30fb\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u65b0\u305f\u306a\u7a2e\u306e\u8a95\u751f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306f\u3001Raptor LC\u30ab\u30e9\u30e0\u306e\u5c0e\u5165\u306b\u3088\u308aSPP\u30b3\u30a2\u30b7\u30a7\u30eb\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u304c\u3088\u308a\u9032\u5316\u3057\u305f\u3068\u81ea\u8ca0\u3057\u3066\u3044\u307e\u3059\u3002\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u306b\u3088\u308a\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u5411\u4e0a\u3057\u3001\u5206\u6790\u6642\u9593\u306f\u5927\u5e45\u306b\u77ed\u7e2e\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u30d4\u30fc\u30af\u5206\u96e2\u306e\u3088\u3046\u306a\u5206\u96e2\u80fd\u306b\u306f\u307b\u3068\u3093\u3069\u5f71\u97ff\u304c\u3042\u308a\u307e\u305b\u3093\u3002\u305d\u3057\u3066\u9078\u629e\u6027\u306f\u5206\u96e2\u80fd\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u304c\u3001\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u306b\u306f\u307b\u3068\u3093\u3069\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u305b\u3093\u3002Raptor LC\u30ab\u30e9\u30e0\u306f\u3001\u5805\u7262\u306a1.8\u30012.7\u30015 \u00b5m\u306e\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u3068Restek\u72ec\u81ea\u306eUltra Selective Liquid Chromatography (USLC)\u56fa\u5b9a\u76f8\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306b\u4e21\u8005\u306e\u9577\u6240\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor LC\u30ab\u30e9\u30e0\u306f\u3001SPP\u306e\u30b9\u30d4\u30fc\u30c9\u3068\u9078\u629e\u6027\u306b\u512a\u308c\u305fUSLC\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u5206\u96e2\u80fd\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u6700\u521d\u306e\u30ab\u30e9\u30e0\u3067\u3042\u308a\u3001\u8fc5\u901f\u304b\u3064\u52b9\u7387\u7684\u306a\u5206\u6790\u6cd5\u958b\u767a\u306e\u305f\u3081\u306e\u6700\u3082\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3092\u7686\u3055\u307e\u3078\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u307e\u305f\u3001Raptor LC\u30ab\u30e9\u30e0\u306f\u3001\u304a\u5ba2\u69d8\u304c\u4fe1\u983c\u3059\u308b\u88fd\u9020\u304a\u3088\u3073\u54c1\u8cea\u30b7\u30b9\u30c6\u30e0\u3001\u305d\u3057\u3066\u696d\u754c\u6700\u9ad8\u306ePlus 1\u30b5\u30fc\u30d3\u30b9\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u304cRestek\u306e\u88fd\u54c1\u3067\u3059\u3002\u91cd\u8981\u306a\u5206\u6790\u306b\u306f\u3001\u305c\u3072Raptor\u3092\u3054\u9078\u629e\u304f\u3060\u3055\u3044\u3002\u9032\u5316\u3057\u305f\u9078\u629e\u6027\u3092\u4f53\u9a13\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>\u56f3 1:\u00a0<\/strong>Raptor LC\u30ab\u30e9\u30e0\u3060\u3051\u304c\u3001 \u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u306e\u9ad8\u3044\u52b9\u7387\u3068USLC\u56fa\u5b9a\u76f8\u306b\u3088\u308b\u5206\u96e2\u80fd\u306e\u5411\u4e0a\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"437\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01A.jpg\" alt=\"\" class=\"wp-image-22989\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01A.jpg 800w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01A-300x164.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01A-768x420.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a\u56fa\u5b9a\u76f8\u306e\u5168\u591a\u5b54\u6027\u7c92\u5b50\u306f\u3001\u4fdd\u6301\u6642\u9593\u304c\u9577\u304f\u3001\u5206\u96e2\u80fd\u306f\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"437\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01B.jpg\" alt=\"\" class=\"wp-image-22995\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01B.jpg 800w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01B-300x164.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01B-768x420.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a\u56fa\u5b9a\u76f8\u306e\u901a\u5e38\u306e\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50(SPP) \u306f\u3001\u5168\u591a\u5b54\u6027\u7c92\u5b50\u306b\u304f\u3089\u3079\u3066\u4fdd\u6301\u6642\u9593\u306f\u77ed\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u5206\u96e2\u80fd\u306f\u4f4e\u3044\u307e\u307e\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"437\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01C.jpg\" alt=\"\" class=\"wp-image-23001\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01C.jpg 800w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01C-300x164.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-01C-768x420.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u9078\u629e\u6027\u306b\u512a\u308c\u305fUSLC\u56fa\u5b9a\u76f8\u3092\u6709\u3059\u308bRaptor LC\u30ab\u30e9\u30e0\u3060\u3051\u304c\u3001\u3088\u308a\u77ed\u3044\u4fdd\u6301\u6642\u9593\u3068\u3088\u308a\u9ad8\u3044\u5206\u96e2\u80fd\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u9032\u5316\u3057\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">USLC\u306e\u9078\u629e\u6027\u3068\u4e00\u4f53\u5316\u3057\u3066\u3053\u305d\u3001\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u52b9\u7387\u6027\u306f\u767a\u63ee\u3055\u308c\u307e\u3059\u3002Raptor\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u8fc5\u901f\u5316\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3067\u304d\u307e\u3059\u3002 2.7\u304a\u3088\u30735 \u00b5m\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5f93\u6765\u306eHPLC\u88c5\u7f6e\u3092\u30a2\u30c3\u30d7\u30b0\u30ec\u30fc\u30c9\u3059\u308b\u3053\u3068\u306a\u304f\u52b9\u7387\u3068\u9078\u629e\u6027\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305d\u3057\u3066Raptor 1.8 \u00b5m LC\u30ab\u30e9\u30e0\u306f\u3001\u30b9\u30e2\u30fc\u30eb\u30b3\u30a2\u7c92\u5b50\u306b\u8868\u9762\u591a\u5b54\u6027\u88ab\u819c\u3068\u3044\u3046\uff12\u3064\u306e\u52b9\u7387\u5316\u3092\u3082\u305f\u3089\u3057\u3001UHPLC\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u767a\u5c55\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u901f\u5206\u6790\u304c\u53ef\u80fd\u3067\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u8abf\u6574\u306b\u6642\u9593\u3092\u8981\u3057\u307e\u305b\u3093\u3002<\/li>\n\n\n\n<li>\u30a2\u30a4\u30bd\u30d0\u30ea\u30c3\u30af\u5316\u5408\u7269\u3084\u5206\u96e2\u306e\u96e3\u3057\u3044\u5316\u5408\u7269\u3092\u5206\u96e2\u3057\u3084\u304f\u3059\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30dc\u30a4\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u4ed8\u8fd1\u3067\u306e\u5316\u5408\u7269\u306e\u6eb6\u51fa\u3092\u907f\u3051\u3001\u30a4\u30aa\u30f3\u30b5\u30d7\u30ec\u30c3\u30b7\u30e7\u30f3\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u8907\u96d1\u306a\u79fb\u52d5\u76f8\u306e\u4f7f\u7528\u3084\u30e1\u30bd\u30c3\u30c9\u3092\u4f55\u5ea6\u3082\u5909\u66f4\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u305b\u3093\u3002<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-theme-palette-7-background-color has-background is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Raptor LC\u30ab\u30e9\u30e0\u306e\u89e3\u5256: \u65b0\u7a2e\u306b\u8feb\u308b<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">\u9069\u5fdc\u80fd\u529b: Raptor LC \u30ab\u30e9\u30e0<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e\u5c02\u9580\u7814\u7a76\u958b\u767a\u30b0\u30eb\u30fc\u30d7\u306f\u3001\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\uff08\u4e00\u822c\u306bSPP\u307e\u305f\u306f\u300c\u30b3\u30a2\u30b7\u30a7\u30eb\u300d\u7c92\u5b50\u3068\u547c\u3070\u308c\u308b\uff09\u306e\u3042\u3089\u3086\u308b\u5074\u9762\u3092\u7814\u7a76\u3057\u3001SPP\u69cb\u9020\u3068Restek\u306e\u9078\u629e\u6027\u306b\u512a\u308c\u305fUSLC\u56fa\u5b9a\u76f8\u306e\u4e21\u65b9\u306b\u6700\u9069\u306a\u30dc\u30f3\u30c7\u30a3\u30f3\u30b0\u30b1\u30df\u30b9\u30c8\u30ea\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002 \u3057\u304b\u3057\u3001\u79c1\u305f\u3061\u306f\u305d\u308c\u3060\u3051\u306b\u3068\u3069\u307e\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u65b0\u3057\u3044\u72ec\u81ea\u306e\u30ab\u30e9\u30e0\u5145\u586b\u6280\u8853\u306e\u5c0e\u5165\u306b\u52a0\u3048\u3001LC\u30ab\u30e9\u30e0\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u3082\u30b0\u30ec\u30fc\u30c9\u30a2\u30c3\u30d7\u3057\u307e\u3057\u305f\u3002\u7c92\u5b50\u3060\u3051\u3067\u306a\u304f\u3001\u5145\u586b\u3084\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306b\u3082\u76ee\u3092\u5411\u3051\u308b\u3053\u3068\u3067\u3001Raptor LC\u30ab\u30e9\u30e0\u306e\u4e00\u3064\u4e00\u3064\u304c\u518d\u73fe\u6027\u306e\u3042\u308b\u5805\u7262\u306a\u6027\u80fd\u3092\u767a\u63ee\u3059\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"606\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNSS1895E-02-1024x606.png\" alt=\"\" class=\"wp-image-23007\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-02-1024x606.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-02-300x177.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-02-768x454.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-02.png 1334w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u53b3\u9078\u3055\u308c\u305f\u30d5\u30ea\u30c3\u30c8<\/strong><br>\u7c92\u5b50\u5f84\u3092\u7cbe\u5bc6\u306b\u5236\u5fa1\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u53ef\u80fd\u306a\u9650\u308a\u30d5\u30ea\u30c3\u30c8\u30b5\u30a4\u30ba\u3092\u5927\u304d\u304f\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u76ee\u8a70\u307e\u308a\u3092\u9632\u304e\u3001\u30ab\u30e9\u30e0\u5bff\u547d\u3092\u5ef6\u3070\u3057\u3001\u6700\u9069\u306a\u5727\u529b\u3092\u7dad\u6301\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u9811\u4e08\u306a\u30e9\u30d9\u30eb<\/strong><br>\u6d41\u91cf\u65b9\u5411\u3068\u30ab\u30e9\u30e0\u306e\u4e21\u65b9\u3092\u660e\u78ba\u306b\u8b58\u5225\u3057\u307e\u3059\u3002\u6eb6\u5a92\u3084\u7834\u308c\u306b\u5f37\u304f\u3001\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3068\u540c\u3058\u3060\u3051\u9577\u6301\u3061\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u72ec\u81ea\u306e\u30ab\u30e9\u30e0\u5145\u586b\u6280\u8853<\/strong><br>\u5727\u529b\u5b89\u5b9a\u6027\u3092\u9ad8\u3081\u3001\u52b9\u7387\u3084\u5bff\u547d\u3092\u72a0\u7272\u306b\u3059\u308b\u3053\u3068\u306a\u304f\u9ad8\u3044\u7dda\u901f\u5ea6\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306fUHPLC\u6ce8\u5165\u30b5\u30a4\u30af\u30eb\u306e\u904e\u9177\u306a\u6761\u4ef6\u4e0b\u3067\u3082\u6301\u3061\u3053\u305f\u3048\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>Raptor SPP\u7c92\u5b50<\/strong><br><em>\u4e00\u9023\u306e\u9811\u4e08\u306a\u7c92\u5b50<\/em><br>2.7\u304a\u3088\u30735 \u00b5m\u7c92\u5b50\u3067\u5f93\u6765\u306eHPLC\u3092\u52a0\u901f\u3057\u30011.8 \u00b5m\u7c92\u5b50\u3067UHPLC\u3092\u30d6\u30fc\u30b9\u30c8\u3057\u307e\u3059\u3002<br><br>\u7c92\u5ea6\u5206\u5e03\u304c\u72ed\u3044\u30b7\u30ea\u30ab<br>\u9ad8\u3044\u52b9\u7387\u3068\u5b89\u5b9a\u3057\u305f\u6d41\u91cf\u3092\u78ba\u4fdd\u3057\u307e\u3059\u3002<br><br>\u30a2\u30c3\u30d7\u30c7\u30fc\u30c8\u3055\u308c\u305f\u5316\u5b66\u7d50\u5408\u6280\u8853\u3068 QC<br>\u30ab\u30e9\u30e0\u9593\u3001\u5206\u6790\u9593\u306b\u304a\u3051\u308b\u4fdd\u6301\u6642\u9593\u306e\u5b89\u5b9a\u6027\u3092\u78ba\u5b9f\u306a\u3082\u306e\u306b\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u4fdd\u5168<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Raptor EXP \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u2014\u3059\u3079\u3066\u306eRaptor\u30ab\u30e9\u30e0\u306b\u5bfe\u5fdc<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">LC\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u6027\u80fd\u3001\u5bff\u547d\u3001\u30d5\u30ea\u30c3\u30c8\u30b5\u30a4\u30ba\u306b\u304b\u304b\u308f\u3089\u305a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30a2\u30c3\u30bb\u30a4\u306b\u4f7f\u7528\u3055\u308c\u308b\u6700\u3082\u9ad8\u4fa1\u306a\u6d88\u8017\u54c1\u3067\u3059\u3002\u305d\u306e\u30b3\u30b9\u30c8\u306b\u898b\u5408\u3046\u3088\u3046\u3001\u3059\u3067\u306b\u9811\u4e08\u306aRaptor LC\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u3055\u3089\u306b\u5ef6\u3070\u3059\u305f\u3081\u306b\u3001\u65b0\u3057\u3044\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\u3068Optimize Technologies\u793e\u304c\u958b\u767a\u3057\u305f\u7279\u8a31\u53d6\u5f97\u6e08\u307f\u306e\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u3092\u7d44\u307f\u5408\u308f\u305b\u307e\u3057\u305f\u3002 \u7279\u306bdilute-and-shoot \u3084\u305d\u306e\u4ed6\u306e\u6700\u5c0f\u9650\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u304a\u3053\u306a\u3046\u5834\u5408\u306b\u306f\u3001\u3069\u3093\u306aRaptor \u30ab\u30e9\u30e0\u3068\u7d44\u5408\u308f\u305b\u3066\u3082\u3001\u5fae\u7c92\u5b50\u3084\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u6c5a\u67d3\u304b\u3089\u306e\u7a76\u6975\u306e\u4fdd\u8b77\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"247\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNSS1895E-03-1024x247.jpg\" alt=\"\" class=\"wp-image-23013\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-03-1024x247.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-03-300x73.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-03-768x186.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-03-1536x371.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>1. \u7279\u8a31\u53d6\u5f97\u6e08\u307f\u30c1\u30bf\u30f3\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9\u30d5\u30a7\u30e9\u30eb<br><\/strong>\u9ad8\u5727\u30b7\u30fc\u30eb\u6027\u3092\u640d\u306a\u3046\u3053\u3068\u306a\u304f\u3001\u7e70\u308a\u8fd4\u3057\u4f7f\u7528\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>2. Free-Turn \u69cb\u9020<br><\/strong>\u5165\u53e3\/\u51fa\u53e3\u306e\u914d\u7ba1\u3092\u5916\u3059\u3053\u3068\u306a\u304f\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u4ea4\u63db\u304c\u53ef\u80fd\u3067\u3001\u30c4\u30fc\u30eb\u306f\u4e0d\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>3. \u81ea\u52d5\u8abf\u6574\u63a5\u7d9a<br><\/strong>\u3042\u3089\u3086\u308b10-32\u30e1\u30b9\u30dd\u30fc\u30c8\u306bZDV(\u30bc\u30ed\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0)\u63a5\u7d9a\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>4.&nbsp;<\/strong><strong>\u67d4\u8edf\u306a\u8a2d\u8a08<br><\/strong>\u7528\u9014\u306b\u5408\u308f\u305b\u3066\u3001\u9577\u3044\u30ca\u30c3\u30c8\u3084\u5de5\u5177\u4e0d\u8981\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\uff08\u4e0b\u8a18\uff09\u306b\u3082\u4ea4\u63db\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>5. \u4e00\u65b9\u5411\u6027Raptor\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<br><\/strong><em>\u30a4\u30f3\u30bf\u30f3\u30c7\u30e0\u958b\u767a<\/em><br>Raptor LC\u30ab\u30e9\u30e0\u3068\u5b8c\u5168\u306b\u7d44\u307f\u5408\u308f\u305b\u3067\u304d\u308b\u3088\u3046\u306b\u4f5c\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u512a\u308c\u305f\u5145\u586b\u6280\u8853<\/em><br>1,034 bar (UHPLC)\/600 bar (2.7 \u00b5m)\/400 bar (5 \u00b5m)\u306e\u52d5\u4f5c\u5727\u529b\u306b\u8010\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e\u54c1\u8cea<br>\u4fe1\u983c\u3067\u304d\u308b\u88fd\u9020\u3068QC\u30b7\u30b9\u30c6\u30e0\u306b\u652f\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30cf\u30a4\u30d6\u30ea\u30c3\u30d5\u30a7\u30e9\u30eb U.S.Patent No.8201854\u3001EXP \u30db\u30eb\u30c0\u30fc U.S.Patent No.8696902\u3001EXP2\u30ec\u30f3\u30c1 U.S.Patent No.D766055. \u305d\u306e\u4ed6\u3001\u7c73\u56fd\u304a\u3088\u3073\u4ed6\u56fd\u306b\u304a\u3044\u3066\u3082\u7279\u8a31\u51fa\u9858\u4e2d\u3067\u3059\u3002 EXP\u3001Free-Turn\u3001\u63a5\u982d\u8a9eOpti-\u306fOptimize Technologies\u306e\u767b\u9332\u5546\u6a19\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\"><strong>UltraShield UHPLC \u30d7\u30ec\u30ab\u30e9\u30e0\u30d5\u30a3\u30eb\u30bf\u30fc\u20141.8 \u00b5m Raptor \u30ab\u30e9\u30e0\u7528<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u3001SLE\u3001\u307e\u305f\u306f\u305d\u306e\u4ed6\u306e\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u304a\u3053\u306a\u3063\u305f\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3057\u30011.8 \u00b5m Raptor \u30ab\u30e9\u30e0\u3068\u3001\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u4ee3\u308f\u308a\u306b UltraShield \u30d5\u30a3\u30eb\u30bf\u30fc\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3068\u3001\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001UHPLC\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u6700\u5927\u5316\u3067\u304d\u307e\u3059\u3002UltraShield\u30d5\u30a3\u30eb\u30bf\u30fc\u306f\u3001\u30ab\u30e9\u30e0\u6027\u80fd\u306b\u307b\u3068\u3093\u3069\u5f71\u97ff\u3092\u4e0e\u3048\u305a\u306b\u5fae\u5c0f\u7c92\u5b50\u304b\u3089\u7d4c\u6e08\u7684\u306b\u4fdd\u8b77\u3057\u300115,000 psi\uff081,034bar\uff09\u307e\u3067\u306e\u8010\u5727\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002 \u3055\u3089\u306b\u3001UltraShield\u30d5\u30a3\u30eb\u30bf\u30fc\u306f\u30b7\u30b9\u30c6\u30e0\u306e\u80cc\u5727\u306e\u5e45\u3092\u5927\u304d\u304f\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"528\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-04.png\" alt=\"\" class=\"wp-image-23019\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-04.png 528w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-04-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS1895E-04-150x150.png 150w\" sizes=\"auto, (max-width: 528px) 100vw, 528px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u9032\u5316\u3057\u305f\u9078\u629e\u6027\u3092\u4f53\u9a13\u3057\u3066\u304f\u3060\u3055\u3044<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Raptor LC\u30ab\u30e9\u30e0\u3068\u30ac\u30fc\u30c9\u3092\u3001\u6700\u3082\u56f0\u96e3\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u305c\u3072\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_4a68e5-48{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_4a68e5-48 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_4a68e5-48 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_4a68e5-48 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_4a68e5-48\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_047d4c-54.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_047d4c-54.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_047d4c-54.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_047d4c-54.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_047d4c-54 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=raptor&#038;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u88fd\u54c1\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_e9af40-ab{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_e9af40-ab .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_e9af40-ab .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_e9af40-ab .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_e9af40-ab\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_b32771-03.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_b32771-03.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_b32771-03.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_b32771-03.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_b32771-03 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/ja\/?s=raptor&#038;sort=discover_searchable_posts_date_desc\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u306e\u8cc7\u6599\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.wp-block-kadence-advancedbtn.kb-btns43812_0dc0c6-97{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43812_0dc0c6-97 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43812_0dc0c6-97 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43812_0dc0c6-97\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43812_f4a5dd-83.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43812_f4a5dd-83.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43812_f4a5dd-83.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43812_f4a5dd-83.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43812_f4a5dd-83 kt-btn-size-standard kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/www.restek.com\/global\/ja\/chromatogram-library\/?s=raptor\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Raptor \u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u898b\u308b<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Raptor LC\u30ab\u30e9\u30e0\u306f\u3001\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\uff08SPP\u307e\u305f\u306f\u300c\u30b3\u30a2\u30b7\u30a7\u30eb\u300d\uff09\u306e\u901f\u5ea6\u3068\u9078\u629e\u6027\u306b\u512a\u308c\u305fUSLC\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u5206\u96e2\u80fd\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7374,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2343,2343],"ppma_author":[414],"class_list":["post-43812","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS1895-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43812"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43812\/revisions"}],"predecessor-version":[{"id":69179,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43812\/revisions\/69179"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7374"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43812"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43812"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43812"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43812"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43812"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43812"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43812"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43812"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}