{"id":43832,"date":"2025-03-20T00:00:00","date_gmt":"2025-03-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-restek-lc-guard-column-selector\/"},"modified":"2026-04-30T14:18:41","modified_gmt":"2026-04-30T14:18:41","slug":"japanese-restek-lc-guard-column-selector","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss2975-ja\/japanese-restek-lc-guard-column-selector","title":{"rendered":"Restek LC \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u9078\u629e"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">LC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u6700\u5927\u306b\u3059\u308b\u305f\u3081\u306e\u8fc5\u901f\u304b\u3064\u8cbb\u7528\u5bfe\u52b9\u679c\u306e\u9ad8\u3044\u65b9\u6cd5\u3067\u3059\u3002\u30ac\u30fc\u30c9\u306f\u30db\u30eb\u30c0\u30fc\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8(\u6642\u306b\u306f\u30d5\u30a3\u30eb\u30bf\u30fc)\u3067\u69cb\u6210\u3055\u308c\u3001\u5f37\u304f\u4fdd\u6301\u3055\u308c\u308b\u4e0d\u7d14\u7269\u3084\u5fae\u7c92\u5b50\u304b\u3089\u4fdd\u8b77\u3059\u308b\u305f\u3081\u306b\u5206\u96e2\u30ab\u30e9\u30e0\u306e\u524d\u306b\u7c21\u5358\u306b\u53d6\u4ed8\u3051\u3089\u308c\u307e\u3059\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u77ed\u304f\u3001\u5bff\u547d\u304c\u9650\u3089\u308c\u305f\u6d88\u8017\u90e8\u54c1\u3067\u3042\u308b\u3053\u3068\u3092\u9664\u3044\u3066\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u3068\u307e\u3063\u305f\u304f\u540c\u69d8\u3067\u3059\u3002LC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u6b63\u3057\u304f\u9078\u629e\u3059\u308b\u65b9\u6cd5\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u306f\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u3092\u4fdd\u8b77\u3057\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u5bff\u547d\u3092\u5ef6\u3070\u3059\u3053\u3068\u306b\u3088\u3063\u3066\u30b3\u30b9\u30c8\u3092\u7bc0\u7d04\u3059\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306f\u3001EXP\u3001Roc\u3001\u304a\u3088\u3073Trident(\u76f4\u63a5\u304a\u3088\u3073\u30a4\u30f3\u30e9\u30a4\u30f3)\u306e3\u3064\u306e\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u69cb\u6210\u3092\u63d0\u4f9b\u3057\u3001\u305d\u308c\u305e\u308c\u306f\u3001\u79c1\u305f\u3061\u306eLC\u30ab\u30e9\u30e0\u30d5\u30a1\u30df\u30ea\u30fc\u306e1\u3064\u306b\u4e00\u81f4\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3001\u7279\u5b9a\u306e\u6280\u8853\u7528\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001UHPLC\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u9ad8\u3044\u80cc\u5727\u304c\u751f\u3058\u308b\u3088\u308a\u5c0f\u3055\u306a\u7c92\u5b50\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u306e\u3067\u3001\u305d\u306e\u5727\u529b\u306b\u5bfe\u5fdc\u3059\u308b\u30db\u30eb\u30c0\u30fc\u304c\u5fc5\u8981\u3067\u3059\u3002\u30ec\u30ac\u30b7\u30fc\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u5f93\u6765\u306eHPLC\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u305d\u308c\u306b\u5408\u3046\u30ec\u30ac\u30b7\u30fc\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u53ce\u5bb9\u3059\u308b\u30db\u30eb\u30c0\u30fc\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b9\u30c6\u30c3\u30d7 1: \u624b\u6cd5\u3068\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u57fa\u3065\u3044\u3066&nbsp;<br>LC\u30ac\u30fc\u30c9\u30b7\u30b9\u30c6\u30e0\u3092\u9078\u629e\u3057\u307e\u3057\u3087\u3046<\/h2>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01.jpg\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">EXP \u30db\u30eb\u30c0\u30fc\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>UHPLC\u306b\u81f3\u308b\u307e\u3067\u3059\u3079\u3066\u306eHPLC\u306b\u9069\u5408\u3057\u3066\u3044\u308b\u30db\u30eb\u30c0\u30fc\u3001\u304a\u3088\u3073\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 (20,000 psi [1400+ bar]\u307e\u3067)\u3002<\/li>\n\n\n\n<li>\u5fc5\u8981\u306b\u5fdc\u3058\u3066LC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u9078\u629e\u3057\u307e\u3059 (Raptor: UHPLC, 2.7 \u00b5m, 5 \u00b5m; Force: 3 \u00b5m and 5 \u00b5m)\u3002<\/li>\n\n\n\n<li>Raptor\u304a\u3088\u3073Force LC\u30ab\u30e9\u30e0\u3067\u4f7f\u7528\u3059\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Roc \u30db\u30eb\u30c0\u30fc\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5f93\u6765\u306eHPLC\u6a5f\u5668\u306b\u5bfe\u5fdc\u3002<\/li>\n\n\n\n<li>Roc HPLC\u30ab\u30e9\u30e0\u3067\u4f7f\u7528\u3059\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Trident \u30c0\u30a4\u30ec\u30af\u30c8\u30db\u30eb\u30c0\u30fc\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5f93\u6765\u306eHPLC\u6a5f\u5668\u306b\u5bfe\u5fdc\u3002<\/li>\n\n\n\n<li>\u30ec\u30ac\u30b7\u30fcHPLC\u30ab\u30e9\u30e0(Ultra\u3001Pinnacle II\u3001Pinnacle DB\u3001Allure)\u3067\u4f7f\u7528\u3059\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li>\uff13\u3064\u306e\u30ec\u30d9\u30eb\u306e\u4fdd\u8b77\u3067\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Trident In-Line \u30db\u30eb\u30c0\u30fc\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5f93\u6765\u306eHPLC\u6a5f\u5668\u306b\u5bfe\u5fdc\u3002<\/li>\n\n\n\n<li>\u30ec\u30ac\u30b7\u30fcHPLC\u30ab\u30e9\u30e0(Ultra\u3001Pinnacle II\u3001Pinnacle DB\u3001Allure)\u3067\u4f7f\u7528\u3059\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5206\u96e2\u30ab\u30e9\u30e0\u3078\u306e\u53d6\u4ed8\u3051\u306b\u306f\u30ab\u30d7\u30e9\u30fc\u304c\u5fc5\u8981\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u5206\u96e2\u30ab\u30e9\u30e0\u4fdd\u8b77\u306e\u305f\u3081\u306e\u6700\u826f\u306e\u9078\u629e\u80a2\u3067\u3059\u304c\u3001\u305d\u308c\u306f\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u3044\u304f\u3089\u304b\u4fdd\u6301\u306e\u30c7\u30a3\u30ec\u30a4\u304c\u751f\u3058\u307e\u3059\u3002\u7121\u8996\u3067\u304d\u308b\u7a0b\u5ea6\u306e\u4f59\u5206\u306a\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3067\u5fae\u7c92\u5b50\u304b\u3089\u4fdd\u8b77\u3059\u308b\u306b\u306f\u3001UltraLine in-line\u30d5\u30a3\u30eb\u30bf&nbsp;\u307e\u305f\u306fUltraShield \u30d5\u30a3\u30eb\u30bf\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3069\u3061\u3089\u3082UHPLC\u306e\u5727\u529b\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fc5\u8981\u306a\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0\u304c\u308f\u304b\u3063\u305f\u3089\u3001\u6b21\u306e\u624b\u9806\u3067\u306f\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u5408\u3063\u305f\u5145\u586b\u5264\u3068\u30b5\u30a4\u30ba\u3092\u5099\u3048\u305fLC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u9078\u629e\u6027\u3084\u52b9\u7387\u3092\u640d\u306a\u3046\u3053\u3068\u306a\u304f\u6700\u5927\u9650\u306e\u9632\u8b77\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u3068\u540c\u3058\u5145\u586b\u5264(\u56fa\u5b9a\u76f8\u3068\u30b7\u30ea\u30ab\u306e\u4e21\u65b9)\u3092\u542b\u3080LC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u9078\u629e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001Raptor Biphenyl2.7\u03bcm\u5206\u96e2\u30ab\u30e9\u30e0\u3068\u3068\u3082\u306b\u4f7f\u7528\u3059\u308b\u305f\u3081\u306e\u6700\u826f\u306eLC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u3001Raptor Biphenyl2.7\u03bcm\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u5408\u3063\u305f\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u5145\u586b\u5264\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306b\u52a0\u3048\u3066\u3001\u6b63\u3057\u3044\u5185\u5f84(ID)\u3092\u6709\u3059\u308bLC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u9078\u629e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3088\u3044\u539f\u5247\u306f\u3001LC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8ID\u304c\u5206\u96e2\u30ab\u30e9\u30e0\u306eID\u3068\u540c\u3058\u3067\u3042\u308b\u304b\u3001\u5206\u96e2\u30ab\u30e9\u30e0\u306eID\u3088\u308a1\u3064\u30b5\u30a4\u30ba\u304c\u5c0f\u3055\u3044\u3053\u3068\u3067\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u5185\u5f844.6\u307e\u305f\u306f4.0mm\u306e\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u306f\u5185\u5f844.0mm\u306e\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u3001\u5185\u5f843.2\u30013.0\u30012.1mm\u306e\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u306f\u5185\u5f842.1mm\u306e\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b9\u30c6\u30c3\u30d7 2: \u5206\u96e2\u30ab\u30e9\u30e0\u306b\u5408\u3063\u305f<br>LC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u5145\u586b\u5264\u3092\u9078\u629e\u3057\u307e\u3059<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">EXP \u30db\u30eb\u30c0\u30fc<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"194\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02.jpg\" alt=\"\" class=\"wp-image-23283\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02-300x65.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02-768x166.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1821\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1822\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/\" rel=\"noreferrer noopener\">Force \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1823\" target=\"_blank\" rel=\"noreferrer noopener\">UltraShield \u30d5\u30a3\u30eb\u30bf<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>LC Column Family<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Particle Size<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Analytical Column Phases<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Guard Cartridge&nbsp;Phases<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"3\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Raptor.jpg\" alt=\"decorative\" width=\"1000\" height=\"1000\" title=\"-\"><\/td><td class=\"has-text-align-left\" data-align=\"left\">1.8 (UHPLC)<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, ARC-18, Biphenyl, FluoroPhenyl<\/td><td class=\"has-text-align-left\" data-align=\"left\">Raptor UHPLC guards: C18, ARC-18, Biphenyl, FluoroPhenyl<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2.7<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, ARC-18, Biphenyl, FluoroPhenyl, HILIC-Si, EtG\/EtS*<\/td><td class=\"has-text-align-left\" data-align=\"left\">Raptor 2.7 \u00b5m guards: C18, ARC-18, Biphenyl, FluoroPhenyl, HILIC-Si<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, ARC-18, Biphenyl, FluoroPhenyl<\/td><td class=\"has-text-align-left\" data-align=\"left\">Raptor 5 \u00b5m guards: C18, ARC-18, Biphenyl, FluoroPhenyl<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"3\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Force.jpg\" alt=\"decorative\" width=\"1000\" height=\"1000\" title=\"-\"><\/td><td class=\"has-text-align-left\" data-align=\"left\">1.8 (UHPLC)<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, Biphenyl, FluoroPhenyl<\/td><td class=\"has-text-align-left\" data-align=\"left\"><br>\u6700\u5927\u9650\u306e\u4fdd\u8b77\u306e\u305f\u3081\u306b\u306f\u540c\u3058\u56fa\u5b9a\u76f8\u306eRaptor UHPLC\u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3002\u307e\u305f\u306f\u3001\u6700\u5c0f\u306e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u304c\u671b\u307e\u308c\u308b\u5834\u5408\u3001\u304d\u308c\u3044\u306a\u30b5\u30f3\u30d7\u30eb\u306e\u305f\u3081\u306b\u306f0.2 \u00b5m UltraShield \u30d5\u30a3\u30eb\u30bf\u30fc**<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, Biphenyl, FluoroPhenyl<\/td><td class=\"has-text-align-left\" data-align=\"left\">Force 5 \u00b5m guards: C18, Biphenyl, FluoroPhenyl<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, Biphenyl, FluoroPhenyl<\/td><td class=\"has-text-align-left\" data-align=\"left\">Force 5 \u00b5m guards: C18, Biphenyl, FluoroPhenyl<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>*Restek\u306f\u3001Raptor EtG\/EtS\u30ab\u30e9\u30e0\u306b\u306f0.2\u03bcm\u306eUltraShield\u30d5\u30a3\u30eb\u30bf\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>**Raptor UHPLC\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u306fRaptor\u7c92\u5b50\u304c\u5145\u586b\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u306eUHPLC\u30ab\u30e9\u30e0\u306b\u3082\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u305f\u3081\u30011.8\u03bcm Force\u304a\u3088\u30731.9\u03bcm Pinnacle DB UHPLC\u30ab\u30e9\u30e0\u306e\u540c\u3058\u56fa\u5b9a\u76f8\u3067\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">ROC \u30db\u30eb\u30c0\u30fc<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03.jpg\" alt=\"\" class=\"wp-image-23289\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03-300x59.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03-768x151.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1824\" target=\"_blank\" rel=\"noreferrer noopener\">Roc \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Family<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Particle<\/strong><br><strong>Size<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Phases<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Guard Cartridge Phases<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Roc.jpg\" alt=\"decorative\" width=\"1000\" height=\"1000\" title=\"-\"><\/td><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td><td class=\"has-text-align-left\" data-align=\"left\">Roc 5 \u00b5m guards: C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td><td class=\"has-text-align-left\" data-align=\"left\">Roc 5 \u00b5m guards: C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Trident \u30db\u30eb\u30c0\u30fc<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"208\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04.jpg\" alt=\"\" class=\"wp-image-23295\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04-300x69.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04-768x177.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1825\" target=\"_blank\" rel=\"noreferrer noopener\">Ultra \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1826\" target=\"_blank\" rel=\"noreferrer noopener\">Pinnacle DB \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1827\" target=\"_blank\" rel=\"noreferrer noopener\">Pinnacle II \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1829\" target=\"_blank\" rel=\"noreferrer noopener\">Allure \u30ac\u30fc\u30c9\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Family<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Particle<\/strong><br><strong>Size<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Column Phases<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Guard Cartridge Phases<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\">Ultra<\/td><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td><td class=\"has-text-align-left\" data-align=\"left\">Ultra 5 \u00b5m guards: C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td><td class=\"has-text-align-left\" data-align=\"left\">Ultra 5 \u00b5m guards: C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"3\">Pinnacle DB<\/td><td class=\"has-text-align-left\" data-align=\"left\">1.9<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, Biphenyl, Aqueous C18, PFP Propyl, Cyano, IBD, Silica, PAH<\/td><td class=\"has-text-align-left\" data-align=\"left\">Raptor UHPLC guard cartridge in matching phase for maximum protection, or 0.2 \u00b5m UltraShield filter for clean samples when minimal dead volume is desired**<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, Biphenyl, Aqueous C18, PFP Propyl, Silica<\/td><td class=\"has-text-align-left\" data-align=\"left\">Pinnacle DB 5 \u00b5m guards: C18, C8, Biphenyl, Aqueous C18, PFP Propyl, Silica<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">C18, C8, Biphenyl, Aqueous C18, PFP Propyl, Cyano, Silica<\/td><td class=\"has-text-align-left\" data-align=\"left\">Pinnacle DB 5 \u00b5m guards: C18, C8, Biphenyl, Aqueous C18, PFP Propyl, Cyano, Silica<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pinnacle II<\/td><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><td class=\"has-text-align-left\" data-align=\"left\">PAH<\/td><td class=\"has-text-align-left\" data-align=\"left\">Pinnacle II 4 \u00b5m guards: PAH<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Allure<\/td><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">Organic Acids, AK, Silica<\/td><td class=\"has-text-align-left\" data-align=\"left\">Allure 5 \u00b5m guards: Organic Acids, AK, Silica<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">**Raptor UHPLC\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u306fRaptor\u7c92\u5b50\u304c\u5145\u586b\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3069\u306eUHPLC\u30ab\u30e9\u30e0\u306b\u3082\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u305f\u3081\u30011.8\u03bcm Force\u304a\u3088\u30731.9\u03bcm Pinnacle DB UHPLC\u30ab\u30e9\u30e0\u306e\u540c\u3058\u56fa\u5b9a\u76f8\u3067\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u6ce8: Trident \u30c0\u30a4\u30ec\u30af\u30c8\u30db\u30eb\u30c0\u30fc\u306f\u30013\u3064\u306e\u69cb\u6210\u3067\u5229\u7528\u53ef\u80fd\u306a\u305f\u3081\u3001\u7528\u9014\u306b\u6700\u9069\u306a\u4fdd\u8b77\u30ec\u30d9\u30eb\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001Trident\u306e\u30ab\u30bf\u30ed\u30b0\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002Trident \u30a4\u30f3\u30e9\u30a4\u30f3\u30d5\u30a3\u30eb\u30bf\u30fc\u3082\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5206\u6790\u6cd5\u3068\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u57fa\u3065\u3044\u3066\u6c7a\u3081\u308b\u5834\u5408\u3001LC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306f\u7c21\u5358\u3067\u3059\u3002\u3053\u306e\u9078\u629e\u30ac\u30a4\u30c9\u3092\u4f7f\u7528\u3057\u3066\u3001\u6700\u9069\u306aLC\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u304a\u9078\u3073\u304f\u3060\u3055\u3044\u3002\u5206\u96e2\u30ab\u30e9\u30e0\u306b\u5bfe\u3059\u308b\u4fdd\u8b77\u3068\u305d\u306e\u6700\u9069\u306a\u6027\u80fd\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":70617,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2343],"ppma_author":[414],"class_list":["post-43832","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS2975-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43832"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43832\/revisions"}],"predecessor-version":[{"id":94152,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43832\/revisions\/94152"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/70617"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43832"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43832"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43832"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43832"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43832"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43832"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43832"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43832"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}