{"id":43837,"date":"2026-08-28T13:36:22","date_gmt":"2026-08-28T13:36:22","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/raptor-polar-x-separate-a-wide-variety-of-polar-analytes-with-a-novel-hybrid-stationary-phase-japan\/"},"modified":"2025-11-25T22:19:30","modified_gmt":"2025-11-25T22:19:30","slug":"raptor-polar-x-separate-a-wide-variety-of-polar-analytes-with-a-novel-hybrid-stationary-phase-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss3195-ja\/raptor-polar-x-separate-a-wide-variety-of-polar-analytes-with-a-novel-hybrid-stationary-phase-japan","title":{"rendered":"Raptor Polar X\uff1a\u591a\u69d8\u306a\u6975\u6027\u6210\u5206\u3092\u5206\u96e2\u3059\u308b\u65b0\u3057\u3044\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9LC\u30ab\u30e9\u30e0"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u9762\u5012\u306a\u8a98\u5c0e\u4f53\u5316\u3084\u7169\u96d1\u306a\u30a4\u30aa\u30f3\u30da\u30a2\u8a66\u85ac\u306e\u4f7f\u7528\u306f\u4e0d\u8981<\/li>\n\n\n\n<li>\u79fb\u52d5\u76f8\u306e\u7c21\u5358\u306a\u5909\u66f4\u3060\u3051\u3067\u4fdd\u6301\u30e2\u30fc\u30c9\u3092\u5207\u308a\u66ff\u3048\u53ef\u80fd\u3067\u3001\u5e73\u8861\u5316\u3082\u77ed\u6642\u9593\u3067\u5b8c\u4e86<\/li>\n\n\n\n<li>LC-MS\u5206\u6790\u3067\u306e\u691c\u51fa\u611f\u5ea6\u3068\u9078\u629e\u6027\u306e\u5411\u4e0a\u306b\u6700\u9069<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u6975\u6027\u5316\u5408\u7269\u5206\u6790\u3092\u30b7\u30f3\u30d7\u30eb\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308b\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306f\u3001\u3053\u308c\u307e\u3067\u9577\u3089\u304f\u56f0\u96e3\u3068\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u4fdd\u6301\u6642\u9593\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3001MS\u306b\u9069\u3055\u306a\u3044\u8907\u96d1\u306a\u79fb\u52d5\u76f8\u3001\u9577\u6642\u9593\u306b\u308f\u305f\u308b\u5e73\u8861\u5316\u3001\u611f\u5ea6\u4f4e\u4e0b\u3001\u3055\u3089\u306b\u306f\u30b5\u30f3\u30d7\u30eb\u8a98\u5c0e\u4f53\u5316\u306e\u5fc5\u8981\u6027\u306a\u3069\u3001\u591a\u304f\u306e\u8ab2\u984c\u304c\u5206\u6790\u52b9\u7387\u3084\u30e9\u30dc\u306e\u751f\u7523\u6027\u3092\u4f4e\u4e0b\u3055\u305b\u3066\u304d\u305f\u306e\u3067\u3059\u3002\u305d\u3053\u3067\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u771f\u306e\u30dd\u30c6\u30f3\u30b7\u30e3\u30eb\u3092\u767a\u63ee\u3055\u305b\u3001\u4e0a\u8ff0\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3059\u3079\u304f\u65b0\u305f\u306b\u958b\u767a\u3057\u305f\u306e\u304c\u3001\u5e45\u5e83\u3044\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u7279\u5316\u3057\u305fLC\u30ab\u30e9\u30e0\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X<\/a>\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u306b\u304a\u3051\u308b\u56fa\u5b9a\u76f8\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u6027\u80fd\u306b\u304a\u3044\u3066\u6700\u3082\u91cd\u8981\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u610f\u5916\u3068\u7406\u89e3\u3055\u308c\u3066\u3044\u306a\u3044\u8981\u7d20\u306e\u3072\u3068\u3064\u304c\u3001\u76ee\u7684\u306b\u9069\u3057\u305f\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306e\u91cd\u8981\u6027\u3067\u3059\u3002\u901a\u5e38\u306e\u9006\u76f8\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u306e\u4fdd\u6301\u3084\u5206\u96e2\u304c\u96e3\u3057\u3044\u305f\u3081\u3001\u8907\u96d1\u306a\u79fb\u52d5\u76f8\u306e\u4f7f\u7528\u3084\u3001\u76ee\u7684\u6210\u5206\u3068\u30ab\u30e9\u30e0\u9593\u306e\u52b9\u679c\u7684\u306a\u76f8\u4e92\u4f5c\u7528\u3092\u88dc\u3046\u305f\u3081\u306e\u30b5\u30f3\u30d7\u30eb\u8a98\u5c0e\u4f53\u5316\u306a\u3069\u304c\u5fc5\u8981\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u76ee\u7684\u6210\u5206\u306b\u6700\u9069\u306a\u56fa\u5b9a\u76f8\u3092\u4f7f\u3048\u3070\u3001\u7c21\u5358\u306a\u524d\u51e6\u7406\u3067\u6642\u9593\u30fb\u30b3\u30b9\u30c8\u3092\u524a\u6e1b\u3057\u3001\u30a8\u30e9\u30fc\u306e\u30ea\u30b9\u30af\u3082\u8efd\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Raptor Polar X\u56fa\u5b9a\u76f8\u306f\u30012\u3064\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\uff08HILIC\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\uff09\u306e\u30d0\u30e9\u30f3\u30b9\u306b\u3088\u308a\u3001\u6975\u6027\u5316\u5408\u7269\u3092\u9078\u629e\u7684\u306b\u4fdd\u6301\u3059\u308b\u3088\u3046\u306b\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u72ec\u81ea\u306e\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9\u56fa\u5b9a\u76f8\u306f\u3001\u7279\u306b\u8cea\u91cf\u5206\u6790\u8a08\u3068\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u884c\u3046\u3001\u591a\u7a2e\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u6700\u9069\u3067\u3059\u3002Restek\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" rel=\"noreferrer noopener\">Raptor Polar X<\/a>\u306e\u5206\u96e2\u6027\u80fd\u3067\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u3092\u30b7\u30f3\u30d7\u30eb\u306a\u3082\u306e\u306b\u3057\u307e\u305b\u3093\u304b\uff1f<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2\u3064\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u878d\u5408\u306b\u3088\u308b\u76f8\u4e57\u52b9\u679c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u5316\u5408\u7269\u306e\u4fdd\u6301\u306b\u4e00\u822c\u7684\u306b\u7528\u3044\u3089\u308c\u308b\u306e\u306f\u3001\u89aa\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08HILIC\uff09\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u3044\u30462\u3064\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3067\u3059\u3002Restek\u304c\u958b\u767a\u3057\u305f\u65b0\u3057\u3044\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u4fdd\u6301\u30e2\u30fc\u30c9\u3092\u5358\u4e00\u30ea\u30ac\u30f3\u30c9\u306b\u7d71\u5408\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u72ec\u81ea\u306e\u30ea\u30ac\u30f3\u30c9\u306f\u591a\u5b54\u8cea\u7c92\u5b50\u306e\u8868\u9762\u306b\u7d50\u5408\u3057\u3066\u3044\u308b\u305f\u3081\u3001Raptor Polar X\u30ab\u30e9\u30e0\u306f\u591a\u69d8\u306a\u6975\u6027\u5206\u6790\u6210\u5206\u3092\u5b89\u5b9a\u7684\u306b\u4fdd\u6301\u3057\u3001\u9ad8\u3044\u5206\u96e2\u52b9\u7387\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f93\u6765\u306e\u7279\u5b9a\u7528\u9014\u5411\u3051\u30ab\u30e9\u30e0\u3067\u306f\u3001\u4e00\u65b9\u306e\u4fdd\u6301\u30e2\u30fc\u30c9\u3092\u512a\u5148\u3059\u308b\u3053\u3068\u3067\u4ed6\u65b9\u306e\u6027\u80fd\u304c\u4f4e\u4e0b\u3057\u3001\u7279\u5b9a\u306e\u6975\u6027\u5316\u5408\u7269\u306e\u307f\u304c\u826f\u597d\u306b\u4fdd\u6301\u3055\u308c\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u5bfe\u3057\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306e\u56fa\u5b9a\u76f8\uff08\u7279\u8a31\u51fa\u9858\u4e2d\uff09\u3067\u306f\u30012\u3064\u306e\u72ec\u7acb\u3057\u305f\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u540c\u6642\u306b\u6d3b\u7528\u3067\u304d\u308b\u305f\u3081\u3001\u30d0\u30e9\u30f3\u30b9\u826f\u304f\u67d4\u8edf\u306a\u4fdd\u6301\u304c\u53ef\u80fd\u3067\u3059\uff08<strong>Figure 1<\/strong>\u53c2\u7167\uff09\u3002\u307e\u305f\u3001\u79fb\u52d5\u76f8\u6761\u4ef6\u306e\u7c21\u5358\u306a\u8abf\u6574\u3060\u3051\u3067\u4fdd\u6301\u30e2\u30fc\u30c9\u3092\u7c21\u5358\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u4f7f\u7528\u524d\u3084\u30b5\u30f3\u30d7\u30eb\u9593\u3067\u306e\u5e73\u8861\u5316\u304c\u9577\u6642\u9593\u306b\u53ca\u3076\u3053\u3068\u306a\u304f\u3001\u76ee\u7684\u306e\u5316\u5408\u7269\u306b\u6700\u9069\u306a\u6761\u4ef6\u3078\u77ed\u6642\u9593\u3067\u79fb\u884c\u3067\u304d\u308b\u306e\u3082\u7279\u5fb4\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Raptor Polar X\u30ab\u30e9\u30e0\u306f\u3001\u79fb\u52d5\u76f8\u6761\u4ef6\u306e\u7c21\u5358\u306a\u8abf\u6574\u3060\u3051\u3067\u6975\u6027\u306e\u4fdd\u6301\u30e2\u30fc\u30c9\u3092\u8fc5\u901f\u304b\u3064\u5bb9\u6613\u306b\u5207\u308a\u66ff\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u540c\u3058\u5206\u6790\u5185\u3067\u3042\u3063\u3066\u3082\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u306e\u4fdd\u6301\u3068\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"826\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu-1024x826.png\" alt=\"\" class=\"wp-image-23301\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu-1024x826.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu-300x242.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu-768x620.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu-1536x1239.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-01-JPsuzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u4fdd\u6301\u30e2\u30fc\u30c9\u306e\u5207\u308a\u66ff\u3048\u30e1\u30ab\u30cb\u30ba\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u6709\u6a5f\u6eb6\u5a92\uff08\u6c34\u306b\u5bfe\u3059\u308b\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u306e\u5272\u5408\u304c\u6bd4\u8f03\u7684\u9ad8\u3044\uff09\u79fb\u52d5\u76f8\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u30b7\u30ea\u30ab\u8868\u9762\u306b\u7d20\u65e9\u304f\u6c34\u5c64\u304c\u5f62\u6210\u3055\u308c\u3001\u6975\u6027\u5316\u5408\u7269\u306f\u305d\u306e\u6c34\u5c64\u306b\u5206\u914d\u3055\u308c\u307e\u3059\u3002\u6c34\u5c64\u3078\u306e\u5206\u914d\u306b\u3088\u308a\u3001\u6975\u6027\u5316\u5408\u7269\u306f\u30b7\u30ea\u30ab\u8868\u9762\u306b\u7d50\u5408\u3057\u305f\u30ea\u30ac\u30f3\u30c9\u3068\u306e\u9593\u3067\u52b9\u679c\u7684\u306a\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u307e\u3059\uff08<strong>Figure 2<\/strong>\u53c2\u7167\uff09\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X<\/a>\u304c\u63a1\u7528\u3057\u3066\u3044\u308b\u65b0\u3057\u3044\u30ea\u30ac\u30f3\u30c9\u306f\u3001\u3053\u306e\u4fdd\u6301\u6a5f\u69cb\u3092\u3055\u3089\u306b\u30b7\u30f3\u30d7\u30eb\u306b\u3057\u3001\u3053\u308c\u307e\u3067\u306b\u306a\u3044\u901f\u3055\u3067\u306e\u30ab\u30e9\u30e0\u306e\u5e73\u8861\u5316\u30fb\u518d\u5e73\u8861\u5316\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3067\u3082\u3059\u3050\u306b\u4f7f\u7528\u53ef\u80fd\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u9593\u306e\u518d\u5e73\u8861\u5316\u306b\u5fc5\u8981\u306a\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3082\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u30b7\u30ea\u30ab\u8868\u9762\u306b\u6c34\u5c64\u304c\u8fc5\u901f\u306b\u5f62\u6210\u3055\u308c\u308b\u3053\u3068\u3067\u3001\u591a\u69d8\u306a\u6975\u6027\u5206\u6790\u6210\u5206\u304c\u79fb\u52d5\u76f8\u4e2d\u306e\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3068\u6c34\u5c64\u306e\u9593\u3067\u5206\u914d\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5206\u914d\u3068\u56fa\u5b9a\u76f8\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u3001HILIC\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"548\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu-1024x548.png\" alt=\"\" class=\"wp-image-23325\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu-1024x548.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu-300x161.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu-768x411.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu-1536x823.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-02JP-suzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u6709\u6a5f\u6eb6\u5a92\uff08\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff09\u79fb\u52d5\u76f8\u6761\u4ef6\u4e0b\u3067\u306f\u3001\u5206\u5b50\u91cf\u306e\u5c0f\u3055\u3044\u6975\u6027\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3068\u56fa\u5b9a\u76f8\u8868\u9762\u3068\u306e\u9593\u306b\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u3001\u512a\u308c\u305f\u4fdd\u6301\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u7279\u306b\u3001\u6975\u3081\u3066\u6975\u6027\u304c\u9ad8\u304f\u96fb\u8377\u3092\u5e2f\u3073\u305f\u4f4e\u5206\u5b50\u5316\u5408\u7269\u3067\u3082\u826f\u597d\u306a\u4fdd\u6301\u3092\u793a\u3057\u307e\u3059\u3002\u4fdd\u6301\u6642\u9593\u3092\u3055\u3089\u306b\u6700\u9069\u5316\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u79fb\u52d5\u76f8\u4e2d\u306e\u6c34\u306e\u5272\u5408\u3092\u6bb5\u968e\u7684\u306b\u5897\u3084\u3059\u3060\u3051\u3067\u5bfe\u5fdc\u3067\u304d\u307e\u3059\u3002\u6c34\u5206\u542b\u91cf\u3092\u5897\u3084\u3059\u3053\u3068\u3067\u3001\u8377\u96fb\u3057\u305f\u6975\u6027\u5316\u5408\u7269\u306f\u5f90\u3005\u306b\u79fb\u52d5\u76f8\u5074\u3078\u79fb\u52d5\u3057\u3084\u3059\u304f\u306a\u308a\u3001\u52b9\u7387\u7684\u306a\u6eb6\u51fa\u304c\u5b9f\u73fe\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u79fb\u52d5\u76f8\u306e\u6c34\u5206\u6bd4\u7387\u3092\u9ad8\u3081\u3066\u3044\u304f\u3068\u3001HILIC\u306b\u5178\u578b\u7684\u306a\u300c\u6c34\u5c64\u3078\u306e\u5206\u914d\u300d\u306b\u3088\u308b\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306f\u6b21\u7b2c\u306b\u5f31\u307e\u308a\u3001\u4ee3\u308f\u3063\u3066\u56fa\u5b9a\u76f8\u304c\u6301\u3064\u30a4\u30aa\u30f3\u4ea4\u63db\u7279\u6027\u304c\u4e3b\u8981\u306a\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3068\u3057\u3066\u50cd\u304f\u3088\u3046\u306b\u306a\u308a\u307e\u3059\uff08<strong>Figure 3<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> \u79fb\u52d5\u76f8\u306e\u6c34\u5206\u6bd4\u7387\u304c\u9ad8\u3044\u3068\u3044\u3046\u6761\u4ef6\u4e0b\u3067\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u30a4\u30aa\u30f3\u4ea4\u63db\u30e1\u30ab\u30cb\u30ba\u30e0\u304c\u4e3b\u8981\u306a\u4fdd\u6301\u30e2\u30fc\u30c9\u3068\u306a\u308a\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"489\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu-1024x489.png\" alt=\"\" class=\"wp-image-23337\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu-1024x489.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu-300x143.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu-768x367.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu-1536x734.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS3195-03JP-suzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u4fdd\u6301\u30e2\u30fc\u30c9\u5207\u308a\u66ff\u3048\u306e\u5b9f\u4f8b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u539f\u7406\u306e\u5b9f\u969b\u7684\u306a\u6319\u52d5\u3092\u793a\u3059\u305f\u3081\u306b\u3001<strong>Figure 4<\/strong>\u3067\u306f\u30012\u7a2e\u985e\u306e\u4ee3\u8868\u7684\u306a\u6975\u6027\u5316\u5408\u7269\u304c\u56fa\u5b9a\u76f8\u3068\u3069\u306e\u3088\u3046\u306b\u76f8\u4e92\u4f5c\u7528\u3057\u3001\u79fb\u52d5\u76f8\u7d44\u6210\u306e\u5909\u5316\u306b\u3088\u3063\u3066\u305d\u308c\u3089\u306e\u4fdd\u6301\u3084\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u3069\u306e\u3088\u3046\u306b\u5909\u5316\u3059\u308b\u304b\u3092\u6bd4\u8f03\u3057\u3066\u3044\u307e\u3059\u3002\u5177\u4f53\u7684\u306a\u4f8b\u3068\u3057\u3066\u3001\u6709\u6a5f\u9178\u3067\u3042\u308b\u30d3\u30bf\u30df\u30f3B3\uff08\u30ca\u30a4\u30a2\u30b7\u30f3\uff09\u3068\u3001\u6c38\u4e45\u7684\u306a\u6b63\u96fb\u8377\u3092\u6301\u3064\u30d3\u30bf\u30df\u30f3B1\uff08\u30c1\u30a2\u30df\u30f3\uff09\u3068\u3044\u3046\u3001\u7570\u306a\u308b\u6975\u6027\u30fb\u96fb\u8377\u7279\u6027\u3092\u6301\u30642\u7a2e\u985e\u306e\u6c34\u6eb6\u6027\u30d3\u30bf\u30df\u30f3\u3092\u5206\u6790\u5bfe\u8c61\u3068\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u6bb5\u306b\u3042\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001HILIC\u5206\u96e2\u306b\u9069\u3057\u305f\u9ad8\u6709\u6a5f\u89e6\u5a92\uff08\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff09\u79fb\u52d5\u76f8\u6761\u4ef6\u3067\u53d6\u5f97\u3055\u308c\u305f\u3082\u306e\u3067\u3059\u3002\u3053\u306e\u6761\u4ef6\u4e0b\u3067<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u30b7\u30ea\u30ab\u7c92\u5b50\u306e\u8868\u9762\u306b\u901f\u3084\u304b\u306b\u6c34\u5c64\u304c\u5f62\u6210\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6975\u6027\u5316\u5408\u7269\u306f\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u79fb\u52d5\u76f8\u304b\u3089\u6c34\u5c64\u3078\u3068\u5206\u914d\u3055\u308c\u3001\u30b7\u30ea\u30ab\u8868\u9762\u304a\u3088\u3073\u56fa\u5b9a\u76f8\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u901a\u3058\u3066\u4fdd\u6301\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3057\u3066\u3001\u6975\u6027\u5316\u5408\u7269\u306f\u56fa\u5b9a\u76f8\u3068\u306e\u89aa\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u3063\u3066\u4fdd\u6301\u3055\u308c\u306a\u304c\u3089\u3082\u3001\u9ad8\u6709\u6a5f\u6eb6\u5a92\u6761\u4ef6\u4e0b\u306e\u307e\u307e\u3067\u3082\u30b9\u30e0\u30fc\u30ba\u306b\u6eb6\u51fa\u304c\u53ef\u80fd\u3067\u3059\u3002\u52a0\u3048\u3066\u3001\u3053\u306e\u3088\u3046\u306a\u9ad8\u6709\u6a5f\u6eb6\u5a92\u6761\u4ef6\u306f\u3001\u8131\u6eb6\u5a92\u52b9\u7387\u3084\u30a4\u30aa\u30f3\u5316\u52b9\u7387\u306e\u5411\u4e0a\u306b\u3082\u5bc4\u4e0e\u3059\u308b\u305f\u3081\u3001LC-MS\/MS\u5206\u6790\u306b\u3001\u975e\u5e38\u306b\u9069\u3057\u305f\u6761\u4ef6\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u4e0b\u6bb5\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001\u79fb\u52d5\u76f8\u4e2d\u306e\u6c34\u306e\u5272\u5408\u3092\u5897\u3084\u3057\u3001\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u304cHILIC\u304b\u3089\u30a4\u30aa\u30f3\u4ea4\u63db\u3078\u3068\u5f90\u3005\u306b\u5207\u308a\u66ff\u308f\u308b\u6761\u4ef6\u3067\u53d6\u5f97\u3055\u308c\u307e\u3057\u305f\u3002\u6c34\u5206\u6bd4\u7387\u306e\u4e0a\u6607\u306b\u4f34\u3044\u3001\u6c34\u5c64\u3078\u306e\u5206\u914d\u306b\u652f\u914d\u3055\u308c\u305fHILIC\u7684\u306a\u4fdd\u6301\u306f\u5f31\u307e\u308a\u3001\u56fa\u5b9a\u76f8\u306e\u30a4\u30aa\u30f3\u4ea4\u63db\u7279\u6027\u306b\u3088\u308b\u4fdd\u6301\u304c\u512a\u52e2\u3068\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u30d3\u30bf\u30df\u30f3B1\u3001\u30d3\u30bf\u30df\u30f3B3\u3068\u3082\u306b\u4fdd\u6301\u304c\u5f31\u307e\u308a\u3001\u7279\u306b\u30d3\u30bf\u30df\u30f3B1\uff08\u6b63\u96fb\u8377\uff09\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u306b\u304a\u3044\u3066\u4fdd\u6301\u3055\u308c\u306b\u304f\u304f\u306a\u308b\u305f\u3081\u3001\u6eb6\u51fa\u9806\u5e8f\u306b\u3082\u5909\u5316\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> MS\u306b\u9069\u3057\u305f\u79fb\u52d5\u76f8\u306e\u6c34\u5206\u6bd4\u7387\u3092\u5909\u66f4\u3059\u308b\u3060\u3051\u3067\u3001\u65b0\u3057\u3044Raptor Polar X\u56fa\u5b9a\u76f8\u3067\u5229\u7528\u53ef\u80fd\u306aHILIC\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u3044\u3046\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u5207\u308a\u66ff\u3048\u304c\u53ef\u80fd\u3067\u3059\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0652.png\" alt=\"Raptor Polar X Retention Mode Comparison: Buffered B Vitamins with 95% vs. 60% Mobile Phase B\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0652<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vitamin B3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-67-6\/Vitamin B3\" target=\"_blank\" rel=\"noopener\">Vitamin B3<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vitamin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-43-8\/Vitamin B1\" target=\"_blank\" rel=\"noopener\">Vitamin B1<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A52<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0652.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30d0\u30e9\u30f3\u30b9\u306e\u3068\u308c\u305f\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3067\u3001\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u3092\u5358\u4e00\u30e1\u30bd\u30c3\u30c9\u3067\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u306f\u7279\u5b9a\u306e\u76f8\u4e92\u4f5c\u7528\u306b\u7279\u5316\u3057\u3001\u4ed6\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u6392\u9664\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u6790\u6210\u5206\u306e\u6027\u8cea\u304c\u4f3c\u3066\u3044\u308b\u5834\u5408\u306f\u6709\u52b9\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u6975\u6027\u5316\u5408\u7269\u306f\u5e45\u5e83\u3044\u5316\u5b66\u7684\u7279\u6027\u3092\u6301\u3061\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u5f93\u6765\u306f\u3001\u5316\u5408\u7269\u306e\u7a2e\u985e\u3054\u3068\u306b\u7570\u306a\u308b\u30ab\u30e9\u30e0\u3084\u6761\u4ef6\u3092\u7528\u3044\u3001\u8907\u6570\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u4f7f\u3044\u5206\u3051\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306e\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9\u306a\u56fa\u5b9a\u76f8\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306f\u30de\u30eb\u30c1\u30e2\u30fc\u30c9\u3067\u3042\u308b\u305f\u3081\u3001\u591a\u69d8\u306a\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u6790\u6210\u5206\u3092\u5358\u4e00\u30e1\u30bd\u30c3\u30c9\u3067\u4e00\u6589\u5206\u6790\u3067\u304d\u307e\u3059\u3002\u4ee5\u4e0b\u306b\u305d\u306e\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">QuPPe\u30e1\u30bd\u30c3\u30c9\u306b\u30a4\u30f3\u30b9\u30d1\u30a4\u30a2\u3055\u308c\u305f\u6975\u6027\u6c5a\u67d3\u7269\u8cea\u30ea\u30b9\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b27\u5ddeQuPPe\uff08<strong>Q<\/strong>uick <strong>P<\/strong>olar <strong>P<\/strong>esticides\uff09\u30e1\u30bd\u30c3\u30c9\u304c\u5206\u6790\u5bfe\u8c61\u3068\u3059\u308b\u306e\u306f\u3001\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u3084\u95a2\u9023\u5316\u5408\u7269\u3068\u3044\u3063\u305f\u9670\u30a4\u30aa\u30f3\u6027\u306e\u6975\u6027\u9664\u8349\u5264\u304b\u3089\u3001\u30af\u30ed\u30ec\u30fc\u30c8\u3084\u30d1\u30fc\u30af\u30ed\u30ec\u30fc\u30c8\u306a\u3069\u306e\u3055\u307e\u3056\u307e\u306a\u30aa\u30ad\u30b7\u30af\u30ed\u30ed\u7cfb\u6c5a\u67d3\u7269\u8cea\u306b\u81f3\u308b\u307e\u3067\u306e\u5e45\u5e83\u3044\u6975\u6027\u5316\u5408\u7269\u3067\u3059\u3002<strong>Figure 5<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u3067\u306f\u3001\u3053\u3046\u3057\u305f\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u6df7\u5408\u7269\u3092\u4fdd\u6301\u3057\u3001\u8fc5\u901f\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3082\u3063\u3068\u3082\u4fdd\u6301\u306e\u5f37\u3044\u5316\u5408\u7269\u3067\u3082\u7d0410.5\u5206\u3067\u6eb6\u51fa\u3057\u3001\u30c8\u30fc\u30bf\u30eb\u306e\u5206\u6790\u6642\u9593\u306f\u308f\u305a\u304b13\u5206\u3067\u3059\u3002\u3053\u306e\u5206\u96e2\u306f\u30010.5%\u30ae\u9178\u3067\u9178\u6027\u6761\u4ef6\u3068\u3057\u305f\u975e\u7de9\u885d\u7cfb\u306e\u30b7\u30f3\u30d7\u30eb\u306a\u79fb\u52d5\u76f8\u3092\u7528\u3044\u3066\u5b9f\u65bd\u3055\u308c\u3066\u304a\u308a\u3001\u30d4\u30fc\u30af\u306e\u62e1\u304c\u308a\u3084\u30c6\u30fc\u30ea\u30f3\u30b0\u306e\u6291\u5236\u306b\u3082\u5bc4\u4e0e\u3057\u3066\u3044\u307e\u3059\u3002<strong>Figure 5<\/strong>\u306b\u793a\u3057\u305f\u5206\u6790\u6761\u4ef6\u3067\u3001AMPA\u3068N-\u30a2\u30bb\u30c1\u30ebAMPA\u3001\u307e\u305f\u30db\u30bb\u30c1\u30eb\u30a2\u30eb\u30df\u30cb\u30a6\u30e0\u3068\u30ea\u30f3\u9178\u304a\u3088\u3073\u30ea\u30f3\u9178\uff08\u4e00\u90e8\u306e\u30de\u30c8\u30ea\u30af\u30b9\u4e2d\u306b\u4e00\u822c\u7684\u306b\u542b\u307e\u308c\u3001\u5e72\u6e09\u6e90\u3068\u3082\u306a\u308b\uff09\u3068\u3044\u3063\u305f\u3001\u540c\u3058\u3088\u3046\u306a\u30de\u30b9\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u3092\u6709\u3059\u308b\u5316\u5408\u7269\u540c\u58eb\u306b\u3064\u3044\u3066\u3082\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> \u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u3067\u306f\u3001Raptor Polar X \u30ab\u30e9\u30e0\u306e\u30e6\u30cb\u30fc\u30af\u3067\u30d0\u30e9\u30f3\u30b9\u306e\u3068\u308c\u305f\u4fdd\u6301\u7279\u6027\u306b\u3088\u308a\u3001\u591a\u69d8\u306a\u5206\u6790\u6210\u5206\u30921\u56de\u306e\u5206\u6790\u3067\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0546.png\" alt=\"17 Polar Pesticide Panel on Raptor Polar X by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0546<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A32<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0546.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 5<\/strong>\u306b\u793a\u3057\u305fRestek\u304c\u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306b\u52a0\u3048\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X<\/a>\u5206\u6790\u7528\u30ab\u30e9\u30e0\u3068\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u305d\u308c\u305e\u308c\u8a55\u4fa1\u3055\u308c\u3001QuPPe\u30e1\u30bd\u30c3\u30c9\u306b\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002\u307e\u305f\u3001\u30cd\u30ac\u30c6\u30a3\u30d6ESI\u30e2\u30fc\u30c9\u306eLC-MS\/MS\u306b\u3088\u308b\u591a\u69d8\u306a\u6975\u6027\u8fb2\u85ac\u306e\u691c\u51fa\u30e1\u30bd\u30c3\u30c9\u3067\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u975e\u8a98\u5c0e\u4f53\u5316\u30a2\u30df\u30ce\u9178\u306e\u76f4\u63a5\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a2\u30df\u30ce\u9178\u306f\u975e\u5e38\u306b\u6975\u6027\u304c\u9ad8\u304f\u591a\u69d8\u306a\u69cb\u9020\u3092\u6301\u3061\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u5f93\u6765\u306f\u3001\u524d\u51e6\u7406\u307e\u305f\u306f\u5f8c\u51e6\u7406\u3067\u306e\u8a98\u5c0e\u4f53\u5316\u3092\u4f34\u3046\u3001\u9006\u76f8\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3084\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306e\u5206\u6790\u3092\u884c\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u8a98\u5c0e\u4f53\u5316\u3092\u884c\u308f\u306a\u3044\u3068\u3001\u4fdd\u6301\u304c\u5f31\u304f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u3057\u3066\u5341\u5206\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u306b\u304f\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u3063\u305f\u304b\u3089\u3067\u3059\u3002\u3057\u304b\u3057\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u3092\u4f7f\u3048\u3070\u3001\u8a98\u5c0e\u4f53\u5316\u3092\u884c\u308f\u306a\u304f\u3066\u3082\u3001\u975e\u6975\u6027\u3001\u6975\u6027\u3001\u6b63\u96fb\u8377\u3001\u8ca0\u96fb\u8377\u306e\u3044\u305a\u308c\u306e\u5074\u9396\u3092\u6301\u3064\u3069\u3093\u306a\u30a2\u30df\u30ce\u9178\u3082\u3001\u5358\u4e00\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u3057\u3063\u304b\u308a\u3068\u4fdd\u6301\u3057\u3001\u660e\u77ad\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<strong>Figure 6<\/strong>\u3067\u306f\u3001\u6db2\u72b6\u306e\u4e73\u5150\u7528\u8abf\u88fd\u7c89\u4e73\u30de\u30c8\u30ea\u30af\u30b9\u4e2d\u306e\u30bf\u30a6\u30ea\u30f3\u306a\u3069\u3092\u542b\u308021\u7a2e\u985e\u306e\u30a2\u30df\u30ce\u9178\u306e\u5206\u6790\u3092\u3001\u30b7\u30f3\u30d7\u30eb\u306a\u305f\u3093\u3071\u304f\u8cea\u6c88\u6bbf\u3067\u5f97\u3089\u308c\u305f\u62bd\u51fa\u7269\u306e\u76f4\u63a5\u5206\u6790\u3067\u884c\u3063\u305f\u4f8b\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> \u4ee5\u4e0b\u306b\u793a\u3059\u30a2\u30df\u30ce\u9178\u306e\u3088\u3046\u306b\u6975\u6027\u304c\u7570\u306a\u308b\u5316\u5408\u7269\u3067\u3042\u3063\u3066\u3082\u3001Raptor Polar X \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308c\u3070\u540c\u4e00\u30e1\u30bd\u30c3\u30c9\u3067\u5206\u6790\u3067\u304d\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0579.png\" alt=\"Underivatized Amino Acids Analysis in Baby Formula on Raptor Polar X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FF0579<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>amino acid<\/li><li>amino acids<\/li><li>underivatized<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0579.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u8d85\u77ed\u9396PFAS\u304b\u3089\u9577\u9396PFAS\u307e\u3067<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306e\u6301\u3064\u4fdd\u6301\u7279\u6027\u3068\u6c4e\u7528\u6027\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u751f\u7523\u6027\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3059\u3060\u3051\u3067\u306a\u304f\u3001\u5c06\u6765\u306e\u5206\u6790\u8ab2\u984c\u306b\u3082\u5bfe\u5fdc\u53ef\u80fd\u306a\u67d4\u8edf\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4ee3\u8868\u7684\u306a\u5fdc\u7528\u4f8b\u304c\u3001\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306e\u9ad8\u5ea6\u306a\u5206\u6790\u3067\u3059\u3002\u73fe\u5728\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u308bLC-MS\/MS\u306b\u3088\u308bPFAS\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u4e3b\u306b\u77ed\u9396\uff08C4\u2013C6\uff09\u304a\u3088\u3073\u9577\u9396\uff08C8\u4ee5\u4e0a\uff09PFAS\u3001\u304a\u3088\u3073\u3044\u308f\u3086\u308b\u4ee3\u66ff\u578bPFAS\u306b\u7126\u70b9\u3092\u5f53\u3066\u3066\u304a\u308a\u3001C2\u304a\u3088\u3073C3\u306e\u8d85\u77ed\u9396PFAS\u306f\u5bfe\u8c61\u5916\u3068\u306a\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u307b\u3068\u3093\u3069\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u308c\u3089\u306e\u8d85\u77ed\u9396PFAS\u306f\u74b0\u5883\u4e2d\u3067\u306e\u5b58\u5728\u304c\u5831\u544a\u3055\u308c\u3064\u3064\u3042\u308a\u3001\u4eca\u5f8c\u306e\u898f\u5236\u3084\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u306b\u304a\u3044\u3066\u91cd\u8981\u306a\u5206\u6790\u5bfe\u8c61\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u8d85\u77ed\u9396PFAS\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5f93\u6765\u306e\u9006\u76f8LC\u6cd5\u3067\u306f\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u3067\u3042\u308a\u3001\u5341\u5206\u306a\u691c\u51fa\u611f\u5ea6\u3084\u5206\u96e2\u3092\u5f97\u306b\u304f\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7528\u3044\u308b\u624b\u6cd5\u3067\u306f\u3001\u9006\u306b\u4fdd\u6301\u304c\u5f37\u3059\u304e\u3066\u6eb6\u51fa\u304c\u9045\u308c\u3001\u5168\u4f53\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u304c\u4f4e\u4e0b\u3059\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u3057\u3066\u3001Raptor Polar X\u30ab\u30e9\u30e0\u306f\u3001\u89aa\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\uff08HILIC\uff09\u3068\u30a2\u30cb\u30aa\u30f3\u4ea4\u63db\u30e2\u30fc\u30c9\u3092\u878d\u5408\u3055\u305b\u305f\u72ec\u81ea\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u8d85\u77ed\u9396\u304b\u3089\u9577\u9396\u306b\u308f\u305f\u308b\u591a\u69d8\u306aPFAS\u5316\u5408\u7269\u3092\u5358\u4e00\u6761\u4ef6\u3067\u52b9\u7387\u7684\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<strong>Figure 7<\/strong>\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001\u3053\u306e\u30ab\u30e9\u30e0\u3067\u306f\u8d85\u77ed\u9396\u304a\u3088\u3073\u9577\u9396\u306ePFAS\u3092\u3001\u305f\u3063\u305f5\u5206\u9593\u306e\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u6761\u4ef6\u3067\u9ad8\u5206\u96e2\u304b\u3064\u8fc5\u901f\u306b\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> \u65b0\u3057\u3044Raptor Polar X\u56fa\u5b9a\u76f8\u3092\u7528\u3044\u305f\u5358\u4e00\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u308b\u8d85\u77ed\u9396\uff08Ultrashort\uff09PFAS\u3001\u5f93\u6765\u578b\uff08\u9577\u9396\uff09PFAS\u3001\u304a\u3088\u3073\u4ee3\u66ff\u578b\uff08Alternative:\u77ed\u9396\uff09PFAS \u306e\u5206\u6790\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.png\" alt=\"Ultrashort- Through Long-Chain and Alternative PFAS on Raptor Polar X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0569<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">11-Chloroeicosafluoro-3-oxanonane-1-sulfonate (11CL-PF3OUdS)<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">400<\/td><td class=\"oth\">630.78<\/td><td class=\"oth\">450.80<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate (9Cl-PF3ONS)<\/td><td class=\"oth\">1.34<\/td><td class=\"oth\">400<\/td><td class=\"oth\">530.78<\/td><td class=\"oth\">350.85<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanesulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanesulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">1.38<\/td><td class=\"oth\">400<\/td><td class=\"oth\">498.84<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanesulfonic acid (PFHxS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanesulfonic acid (PFHxS)<\/a><\/td><td class=\"oth\">1.49<\/td><td class=\"oth\">400<\/td><td class=\"oth\">398.90<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanesulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanesulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">1.64<\/td><td class=\"oth\">400<\/td><td class=\"oth\">298.97<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Perfluoropropanesulfonic acid (PFPrS)<\/td><td class=\"oth\">1.73<\/td><td class=\"oth\">400<\/td><td class=\"oth\">248.97<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\">Perfluoroethanesulfonic acid (PFEtS)<\/td><td class=\"oth\">1.86<\/td><td class=\"oth\">400<\/td><td class=\"oth\">198.98<\/td><td class=\"oth\">79.92<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">284.97<\/td><td class=\"oth\">168.92<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">2.11<\/td><td class=\"oth\">400<\/td><td class=\"oth\">412.90<\/td><td class=\"oth\">368.91<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/Ammonium 4,8-dioxa-3H-perfluorononanoate\" target=\"_blank\" rel=\"noopener\">Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)<\/a><\/td><td class=\"oth\">2.15<\/td><td class=\"oth\">400<\/td><td class=\"oth\">376.90<\/td><td class=\"oth\">250.93<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">2.36<\/td><td class=\"oth\">400<\/td><td class=\"oth\">312.97<\/td><td class=\"oth\">268.90<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">2.76<\/td><td class=\"oth\">400<\/td><td class=\"oth\">212.97<\/td><td class=\"oth\">168.97<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">Perfluoropropionic acid (PFPrA)<\/td><td class=\"oth\">3.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">163.03<\/td><td class=\"oth\">119.01<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluoroacetic acid (TFA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-05-1\/Trifluoroacetic acid\" target=\"_blank\" rel=\"noopener\">Trifluoroacetic acid (TFA)<\/a><\/td><td class=\"oth\">3.77<\/td><td class=\"oth\">400<\/td><td class=\"oth\">113.03<\/td><td class=\"oth\">69.01<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>ultrashort-chain<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u4e0d\u52d5\u614b\u5316\u306f\u5fc5\u8981\uff1f\u4e0d\u8981\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306fLC\u30b7\u30b9\u30c6\u30e0\u5185\u306e\u91d1\u5c5e\u3068\u30ad\u30ec\u30fc\u30c8\u7d50\u5408\u3057\u3084\u3059\u3044\u305f\u3081\u3001\u5fae\u91cf\u30ec\u30d9\u30eb\u3067\u306e\u5206\u6790\u304c\u56f0\u96e3\u306a\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u81ea\u4f53\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u901a\u308b\u6d41\u8def\u306b\u7279\u5225\u306a\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u304a\u308a\u3001\u7814\u7a76\u5ba4\u306b\u5c4a\u3044\u305f\u6642\u70b9\u3067\u3059\u3050\u306b\u4f7f\u7528\u3067\u304d\u308b\u72b6\u614b\u3067\u3059\u304c\u3001LC\u30b7\u30b9\u30c6\u30e0\u5168\u4f53\u306e\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u306b\u306f\u91d1\u5c5e\u90e8\u54c1\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u4e0d\u52d5\u614b\u5316\u51e6\u7406\u3092\u884c\u3046\u3053\u3068\u3067\u5206\u6790\u6027\u80fd\u3092\u3055\u3089\u306b\u5411\u4e0a\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5b9f\u969b\u306b\u4e0d\u52d5\u614b\u5316\u304c\u5fc5\u8981\u304b\u3069\u3046\u304b\u306f\u3001\u4f7f\u7528\u3059\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3084\u88c5\u7f6e\u306e\u69cb\u6210\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30b0\u30ea\u30db\u30b5\u30fc\u30c8\u306e\u3088\u3046\u306b\u30ad\u30ec\u30fc\u30c8\u5316\u3059\u308b\u3053\u3068\u304c\u5206\u304b\u3063\u3066\u3044\u308b\u6975\u6027\u5316\u5408\u7269\u3092\u5bfe\u8c61\u3068\u3059\u308b\u5206\u6790\u3067\u306f\u3001Restek\u793e\u306f\u5206\u6790\u3092\u958b\u59cb\u3059\u308b\u524d\u306bLC Passivation Solution\uff08cat.# 32475\uff09\u306b\u3088\u308b\u51e6\u7406\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9a\u8a55\u3042\u308bRaptor\u54c1\u8cea\u3092\u7d99\u627f\u3057\u305f\u65b0\u3057\u3044\u56fa\u5b9a\u76f8\u3000<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306f\u3001\u5f93\u6765\u306eRaptor\u30ab\u30e9\u30e0\u304c\u9ad8\u54c1\u8cea\u306e\u4ee3\u540d\u8a5e\u3068\u3057\u3066\u7bc9\u304d\u4e0a\u3052\u3066\u304d\u305f\u4fe1\u983c\u6027\u3092\u57fa\u76e4\u306b\u3001\u6700\u65b0\u306e\u8a2d\u8a08\u30fb\u88fd\u9020\u30fb\u8a66\u9a13\u57fa\u6e96\u306b\u57fa\u3065\u3044\u3066\u958b\u767a\u3055\u308c\u305f\u65b0\u3057\u3044\u56fa\u5b9a\u76f8\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30db\u30a6\u30ec\u30f3\u30bd\u30a6\u306e\u3088\u3046\u306a\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30af\u30b9\u3092\u542b\u3080\u5b9f\u8a66\u6599\u306b\u304a\u3044\u3066\u3082\u3001\u6ce8\u5165\u3054\u3068\u306b\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3059\u308b\u5805\u7262\u6027\uff08<strong>Figure 8<\/strong>\u53c2\u7167\uff09\u3084\u3001\u9577\u671f\u4f7f\u7528\u5f8c\u306b\u30ab\u30e9\u30e0\u3092\u4ea4\u63db\u3059\u308b\u969b\u306b\u3082\u5b89\u5fc3\u3057\u3066\u4f7f\u3048\u308b\u9ad8\u3044\u30ab\u30e9\u30e0\u9593\u306e\u518d\u73fe\u6027\uff08<strong>Figure 9<\/strong>\u53c2\u7167\uff09\u306a\u3069\u3001Raptor\u30d6\u30e9\u30f3\u30c9\u306a\u3089\u3067\u306f\u306e\u4fe1\u983c\u6027\u3092\u3057\u3063\u304b\u308a\u3068\u53d7\u3051\u7d99\u3044\u3067\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001Raptor Polar X\u30ab\u30e9\u30e0\u306b\u63a1\u7528\u3055\u308c\u305f\u5358\u4e00\u30ea\u30ac\u30f3\u30c9\u306b\u3088\u308b\u30cf\u30a4\u30d6\u30ea\u30c3\u30c9\u4fdd\u6301\u6a5f\u80fd\u306f\u3001\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u306b\u304a\u3044\u3066\u4e00\u8cab\u3057\u305f\u6027\u80fd\u3092\u5b9f\u73fe\u3057\u3001\u5927\u91cf\u306e\u6c34\u6ce8\u5165\u306e\u3088\u3046\u306a\u904e\u9177\u306a\u6761\u4ef6\u4e0b\u3067\u3082\u56fa\u5b9a\u76f8\u306e\u8131\u843d\u304c\u8d77\u3053\u308a\u306b\u304f\u3044\u3068\u3044\u3046\u7279\u9577\u3082\u5099\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> \u30db\u30a6\u30ec\u30f3\u30bd\u30a6\u62bd\u51fa\u6db2\u3092\u6570\u767e\u56de\u6ce8\u5165\u3057\u305f\u5f8c\u3067\u3082\u793a\u3055\u308c\u308b\u3001\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u4fdd\u6301\u6642\u9593\u306e\u5b89\u5b9a\u6027\u306f\u3001\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u304a\u3051\u308b Raptor Polar X \u30ab\u30e9\u30e0\u306e\u5805\u7262\u306a\u6027\u80fd\u3092\u5b9f\u8a3c\u3057\u3066\u3044\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.png\" alt=\"Polar Pesticides in Spinach on Raptor Polar X by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0547<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A0252<\/li><li>9311A32<\/li><li>25846<\/li><li>23984<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> Raptor Polar X \u30ab\u30e9\u30e0\u306f\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30ed\u30c3\u30c8\u9593\u518d\u73fe\u6027\u3092\u63d0\u4f9b\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0543.png\" alt=\"Lot-to-Lot Comparison: Polar Pesticides in Solvent on Raptor Polar X by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0543<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A32<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0543.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Raptor Polar X\u30ab\u30e9\u30e0\uff1a\u6975\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u9769\u547d\u3092\u3082\u305f\u3089\u3059\u65b0\u4e16\u4ee3LC\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4fdd\u6301\u4e0d\u8db3\u3001\u4f4e\u3044\u5fdc\u7b54\u611f\u5ea6\u3001\u8907\u96d1\u306a\u524d\u51e6\u7406 \u2015 \u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306f\u3001\u3053\u308c\u307e\u3067\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u3084\u30e9\u30dc\u5168\u4f53\u306e\u751f\u7523\u6027\u306b\u304a\u3044\u3066\u591a\u304f\u306e\u8ab2\u984c\u3092\u62b1\u3048\u3066\u304d\u307e\u3057\u305f\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1794\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Polar X\u30ab\u30e9\u30e0<\/a>\u306f\u3001\u3053\u3046\u3057\u305f\u9577\u5e74\u306e\u8ab2\u984c\u306b\u5bfe\u3057\u3001\u65b0\u3057\u3044\u56fa\u5b9a\u76f8\u306b\u3088\u308a\u6839\u672c\u7684\u306a\u89e3\u6c7a\u7b56\u3092\u63d0\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306e\u6838\u3068\u306a\u308b\u306e\u306f\u3001HILIC\uff08\u89aa\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u3044\u3046\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u5358\u4e00\u30ea\u30ac\u30f3\u30c9\u306b\u7d71\u5408\u3057\u305f\u3068\u3044\u3046\u8a2d\u8a08\u3067\u3059\u3002\u3053\u306e\u72ec\u81ea\u306e\u30ea\u30ac\u30f3\u30c9\u3092\u3001\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\uff08SPP\uff09\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u3067\u3001Restek\u306f\u591a\u69d8\u306a\u6975\u6027\u3092\u6301\u3064\u6975\u6027\u5316\u5408\u7269\u3092\u4fdd\u6301\u3057\u3001\u52b9\u7387\u7684\u306b\u5206\u96e2\u3059\u308b\u65b0\u305f\u306a\u56fa\u5b9a\u76f8\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u7279\u5fb4\u304c\u751f\u307f\u51fa\u3059\u76f8\u4e57\u52b9\u679c\u306b\u3088\u308a\u3001Raptor Polar X\u30ab\u30e9\u30e0\u306f\u3001\u8907\u96d1\u3067\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u9ad8\u611f\u5ea6\u306b\u5206\u6790\u3059\u308b\u80fd\u529b\u3092\u5b9f\u73fe\u3057\u3001\u591a\u69d8\u306a\u696d\u754c\u306eLC\u5206\u6790\u8005\u306b\u3068\u3063\u3066\u5f37\u529b\u304b\u3064\u6c4e\u7528\u6027\u306e\u9ad8\u3044\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>M. Anastassiades, A.-K. Wachtler, D. I. Kolberg, E. Eichhorn, H. Marks, A. Benkenstein, S. Zechmann; D. Mack, C. Wildgrube, A. Barth, I. Sigalov, S. G\u00f6rlich, D. D\u00f6rk, G. Cerchia, Quick method for the analysis of highly polar pesticides in food involving extraction with acidified methanol and LC &#8211; or ICMS\/MS Measurement &#8211; I. Food of Plant Origin (QuPPe-PO-Method)\u2013Version 12 (published on EURL-SRM website on July 23, 2021).&nbsp;<a href=\"https:\/\/www.eurl-pesticides.eu\/docs\/public\/tmplt_article.asp?LabID=200&amp;CntID=1115&amp;Theme_ID=1&amp;Pdf=False&amp;Lang=EN\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.eurl-pesticides.eu\/docs\/public\/tmplt_article.asp?LabID=200&amp;CntID=1115&amp;Theme_ID=1&amp;Pdf=False&amp;Lang=EN<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">                                \u30ab\u30bf\u30ed\u30b0No. 9311A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 50 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A32\">                                \u30ab\u30bf\u30ed\u30b0No. 9311A32                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 30 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A32\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A12\">                                \u30ab\u30bf\u30ed\u30b0No. 9311A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 100 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A12\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A0252\">                                \u30ab\u30bf\u30ed\u30b0No. 9311A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Polar X, 2.7 \u00b5m, 5 x 2.1 mm EXP Guard Column Cartridge, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9311A0252\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32475\">                                \u30ab\u30bf\u30ed\u30b0No. 32475                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LC Passivation Solution, Methylenediphosphonic Acid (Medronic Acid), 1760 \u00b5g\/mL, Methanol (HPLC grade)\/Water (50:50), 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32475\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>HILIC\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u306e2\u3064\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u7d71\u5408\u3057\u305f\u30cf\u30a4\u30d6\u30ea\u30c3\u30c8LC\u30ab\u30e9\u30e0\u3067\u3042\u308bRaptor Polar X\u3002\u8a98\u5c0e\u4f53\u5316\u3084\u30a4\u30aa\u30f3\u30da\u30a2\u30ea\u30f3\u30b0\u4e0d\u8981\u3067\u591a\u69d8\u306a\u6975\u6027\u5316\u5408\u7269\u3092\u9ad8\u611f\u5ea6\u306b\u5206\u6790\u53ef\u80fd\u3002\u30b7\u30f3\u30d7\u30eb\u306a\u64cd\u4f5c\u3068\u9ad8\u3044\u6c4e\u7528\u6027\u3067\u3001LC\u5206\u6790\u306e\u751f\u7523\u6027\u3092\u98db\u8e8d\u7684\u306b\u5411\u4e0a\u3002<\/p>\n","protected":false},"author":11,"featured_media":7422,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2571,2553],"resource-technique":[2357,2343,2365,2343],"ppma_author":[2814,2814],"class_list":["post-43837","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-hilic-ja","resource-technique-liquid-chromatography-ja","resource-technique-ms-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2357,"label":"HILIC"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS3195-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43837"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43837\/revisions"}],"predecessor-version":[{"id":69180,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43837\/revisions\/69180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7422"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43837"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43837"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43837"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43837"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43837"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43837"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}