{"id":43853,"date":"2023-09-14T00:00:00","date_gmt":"2023-09-14T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/rtx-200-gc-columns-japan\/"},"modified":"2026-08-04T03:15:00","modified_gmt":"2026-08-04T03:15:00","slug":"rtx-200-gc-columns-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss4041-ja\/rtx-200-gc-columns-japan","title":{"rendered":"Rtx-200 GC\u30ab\u30e9\u30e0"},"content":{"rendered":"\n<div style=\"height:46px\" aria-hidden=\"true\" id=\"table_of_contents\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"rtk-toc\">\n<p><strong>\u3010\u76ee\u6b21\u3011<\/strong><\/p>\n<ol>\n  <li><a href=\"#sec01\">\u72ec\u81ea\u306e\u30dd\u30ea\u30de\u30fc\u7d44\u6210\u304c\u72ec\u81ea\u306e\u9078\u629e\u6027\u3092\u5b9f\u73fe<\/a><\/li>\n  <li><a href=\"#sec02\">MS\u306b\u6700\u9069\u306a\u9ad8\u3044\u71b1\u5b89\u5b9a\u6027\u3068\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9<\/a><\/li>\n  <li><a href=\"#sec03\">\u5e45\u5e83\u3044\u7528\u9014<\/a><\/li>\n  <li><a href=\"#sec04\">CFCs<\/a><\/li>\n  <li><a href=\"#sec05\">\u30af\u30ed\u30ed\u30b7\u30e9\u30f3<\/a><\/li>\n  <li><a href=\"#sec06\">\u6eb6\u5a92<\/a><\/li>\n  <li><a href=\"#sec07\">\u98df\u54c1\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u4e2d\u306e\u6bba\u866b\u5264GCxGC\uff08\u4e8c\u6b21\u30ab\u30e9\u30e0\uff09<\/a><\/li>\n  <li><a href=\"#sec08\">\u4f4e\u5727GC-MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4f7f\u3063\u3066\u5206\u6790\u3092\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7<\/a><\/li>\n  <li><a href=\"#sec09\">Pro EZGC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u7c21\u5358\u306b\u5206\u6790\u3092\u6700\u9069\u5316<\/a><\/li>\n<\/ol>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\"><\/div>\n<\/div>\n\n\n\n<h2 id=\"sec01\" class=\"wp-block-heading\"><a id=\"sec01\"><\/a>1. \u72ec\u81ea\u306e\u30dd\u30ea\u30de\u30fc\u7d44\u6210\u304c\u72ec\u81ea\u306e\u9078\u629e\u6027\u3092\u5b9f\u73fe<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15023\" target=\"_blank\" rel=\"noopener\">Rtx-200 GC\u30ab\u30e9\u30e0<\/a>\u306f\u3001\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\u56fa\u5b9a\u76f8\u3067\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u3066\u304a\u308a\u3001\u30b1\u30c8\u30f3\u3001\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30cb\u30c8\u30ed\u542b\u6709\u5316\u5408\u7269\u3001\u30cf\u30ed\u30b2\u30f3\u542b\u6709\u5316\u5408\u7269\u306a\u3069\u3001\u5b64\u7acb\u96fb\u5b50\u5bfe\u3092\u3082\u3064\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u72ec\u81ea\u306e\u9078\u629e\u6027\u3092\u793a\u3057\u307e\u3059\u3002Rtx-200\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u306e\u6975\u6027\u306f\u3001\u975e\u6975\u6027\u307e\u305f\u306f\u6975\u6027\u30ab\u30e9\u30e0\u3067\u306f\u9054\u6210\u3067\u304d\u306a\u3044\u5206\u96e2\u304c\u9054\u6210\u3067\u304d\u308b\u3053\u3068\u304c\u591a\u304f\u3001\u5e45\u5e83\u3044\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u52a0\u3048\u3066\u3001Pro <em>EZ<\/em>GC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3066GC\u5206\u96e2\u3092\u30e2\u30c7\u30eb\u5316\u3059\u308b\u3068\u3001\u6975\u6027\u306e\u7570\u306a\u308b3\u3064\u306e\u30ab\u30e9\u30e0\uff08\u7121\u6975\u6027\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10154\" target=\"_blank\" rel=\"noopener\">Rtx-1<\/a>\u30ab\u30e9\u30e0\u3001\u4e2d\u6975\u6027\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/13870\" target=\"_blank\" rel=\"noopener\">Rxi-624Sil MS<\/a>\u30ab\u30e9\u30e0\u3001\u72ec\u81ea\u306e\u9078\u629e\u7684\u306a<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15054\" target=\"_blank\" rel=\"noopener\">Rtx-200<\/a>\u30ab\u30e9\u30e0\uff09\u306b\u304a\u3044\u3066\u3001\u6c4e\u7528\u7684\u306a\u6eb6\u5a92\u3067\u7570\u306a\u308b\u4fdd\u6301\u6319\u52d5\u3092\u793a\u3057\u307e\u3057\u305f\uff08<strong>Figure 1<\/strong>\uff09\u3002\u540c\u4e00\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u3001Rtx-200\u30ab\u30e9\u30e0\u306f\u3053\u308c\u3089\u306e\u6eb6\u5a92\u3092\u5b8c\u5168\u306b\u5206\u96e2\u3057\u3001Rtx-1\u307e\u305f\u306fRxi-624Sil MS\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u7570\u306a\u308b\u6eb6\u51fa\u6319\u52d5\u3092\u793a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Rtx-200\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u306e\u6975\u6027\u306b\u3088\u308a\u3001\u7121\u6975\u6027\u306eRtx-1\u30ab\u30e9\u30e0\u3084\u4e2d\u6975\u6027\u306eRtx-624Sil MS\u30ab\u30e9\u30e0\u3068\u6bd4\u3079\u306a\u6c4e\u7528\u7684\u306a\u6eb6\u5a92\u306e\u5206\u96e2\u306b\u512a\u308c\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\"><strong>Rtx-200<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"427\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a-1024x427.jpg\" alt=\"\" class=\"wp-image-23427\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a-1024x427.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a-300x125.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a-768x320.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a-1536x640.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01a.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Rtx-1<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"427\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b-1024x427.jpg\" alt=\"\" class=\"wp-image-23433\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b-1024x427.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b-300x125.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b-768x320.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b-1536x640.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01b.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Rtx-624Sil MS<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"427\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c-1024x427.jpg\" alt=\"\" class=\"wp-image-21669\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c-1024x427.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c-300x125.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c-768x320.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c-1536x640.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-01c.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"wp-block-paragraph\"><strong>Peaks<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Chloromethane<\/li>\n\n\n\n<li>Methanol<\/li>\n\n\n\n<li>Bromomethane<\/li>\n\n\n\n<li>Methylene Chloride<\/li>\n\n\n\n<li><em>tert<\/em>-Butyl Alcohol<\/li>\n\n\n\n<li>Chloroform<\/li>\n\n\n\n<li>Benzene<\/li>\n\n\n\n<li>1,2-Dichloroethane<\/li>\n\n\n\n<li>Dibromomethane<\/li>\n\n\n\n<li>Fluorobenzene<\/li>\n\n\n\n<li>2-Chloroethanol<\/li>\n\n\n\n<li>Toluene<\/li>\n\n\n\n<li>Tetrachloroethene<\/li>\n\n\n\n<li>Ethylbenzene<\/li>\n\n\n\n<li>Chlorobenzene<\/li>\n\n\n\n<li><em>o<\/em>-Xylene<\/li>\n\n\n\n<li>Styrene<\/li>\n\n\n\n<li><em>n<\/em>-Propylbenzene<\/li>\n\n\n\n<li>Naphthalene<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Conditions<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Column:<\/strong>&nbsp;30 m, 0.32 mm ID, 1.0 \u00b5m<br><strong>Carrier Gas:<\/strong>&nbsp;Helium, Constant Flow @ 2.0 mL\/min<br><strong>Average Velocity:<\/strong>&nbsp;40.88 cm\/sec<br><strong>Outlet Pressure (abs):<\/strong>&nbsp;14.70 psi<br><strong>Oven Temp.<\/strong>: 35 \u00b0C (hold 1 min) to 235 \u00b0C @ 30 \u00b0C\/min<\/p>\n<\/div>\n<\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec02\" class=\"wp-block-heading\"><a id=\"sec02\"><\/a>2. MS\u306b\u6700\u9069\u306a\u9ad8\u3044\u71b1\u5b89\u5b9a\u6027\u3068\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b89\u5b9a\u3057\u305f\u30ab\u30e9\u30e0\u69cb\u9020\u3092\u6301\u3064<strong>Rtx-200<\/strong>\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15020\" target=\"_blank\" rel=\"noopener\">15020<\/a>\uff09\u306f\u3001\u4f4e\u30d6\u30ea\u30fc\u30c9\u3067360\u00b0C\u307e\u3067\u306e\u71b1\u5b89\u5b9a\u6027\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002\u9ad8\u3044\u71b1\u5b89\u5b9a\u6027\u3092\u8a87\u308bRtx-200\u306e\u6db2\u76f8\u306f\u3001\u9ad8\u611f\u5ea6\u306a\u691c\u51fa\u5668\u3084\u9ad8\u6e29\u3092\u8981\u3059\u308b\u5206\u6790\u306e\u4e21\u65b9\u306b\u9069\u3057\u3066\u3044\u307e\u3059\uff08<strong>Figure 3<\/strong>\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001\u3055\u3089\u306b\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u5fc5\u8981\u3068\u3059\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u3057\u3066\u3001<strong>Rtx-200MS<\/strong>\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15623\" target=\"_blank\" rel=\"noopener\">15623<\/a>\uff09\u30ab\u30e9\u30e0\u306e\u30d6\u30ea\u30fc\u30c9\u4ed5\u69d8\u306fRtx-200\u3088\u308a\u3082\u4f4e\u3044\u305f\u3081\u3001\u9ad8\u611f\u5ea6\u306a\u8cea\u91cf\u5206\u6790\u88c5\u7f6e\u3092\u4f7f\u7528\u3059\u308b\u30e9\u30dc\u306b\u6700\u9069\u3067\u3059\uff08<strong>Figure 2<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0Rtx-200\u30ab\u30e9\u30e0\u306e\u512a\u308c\u305f\u71b1\u5b89\u5b9a\u6027\u304c\u3001\u9ad8\u6e29\u4e0b\u306b\u304a\u3044\u3066\u4f4e\u30d6\u30ea\u30fc\u30c9\u3092\u5b9f\u73fe\u3057\u307e\u3059\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1228.png\" alt=\"Bleed from Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1228<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>15623<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>bleed<\/li><li>rtx-200<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1228.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0Rtx-200\u30ab\u30e9\u30e0\u306f\u30b7\u30ed\u30ad\u30b5\u30f3\u306e\u3088\u3046\u306a\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u3067\u3042\u3063\u3066\u3082\u3001360\u00b0C\u3067\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u793a\u3057\u307e\u3059\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00360.png\" alt=\"Siloxane (Polymethyl) on Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CH00360<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>15020<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00360.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec03\" class=\"wp-block-heading\"><a id=\"sec03\"><\/a>3. \u5e45\u5e83\u3044\u7528\u9014<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15023\" target=\"_blank\" rel=\"noopener\">Rtx-200\u30ab\u30e9\u30e0<\/a>\u306f\u3055\u307e\u3056\u307e\u306a\u5bf8\u6cd5\uff08\u9577\u3055\u3001\u5185\u5f84\u3001\u819c\u539a\uff09\u3067\u5229\u7528\u53ef\u80fd\u3067\u3042\u308a\u3001\u6eb6\u5a92\u304b\u3089\u30b7\u30e9\u30f3\u3001\u8fb2\u85ac\u307e\u3067\u5e45\u5e83\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002Rtx-200\u30ab\u30e9\u30e0\u306f\u4e2d\u6027\u3067\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u305f\u3081\u3001\u9178\u6027\u3001\u5869\u57fa\u6027\u3001\u307e\u305f\u306f\u4e2d\u6027\u306e\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u6d3b\u7528\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u305d\u306e\u72ec\u7279\u306e\u6975\u6027\u306b\u3088\u308a\u3001\u4ed6\u306e\u591a\u304f\u306e\u56fa\u5b9a\u76f8\u3068\u6bd4\u8f03\u3057\u3066\u7570\u306a\u308b\u6eb6\u51fa\u30d1\u30bf\u30fc\u30f3\u304c\u751f\u3058\u308b\u305f\u3081\u3001\u591a\u304f\u306e\u5206\u6790\u306b\u3068\u3063\u3066\u7406\u60f3\u7684\u306a\u78ba\u8a8d\u30ab\u30e9\u30e0\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec04\" class=\"wp-block-heading\"><a id=\"sec04\"><\/a>4. CFCs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 4<\/strong>\u306e\u5206\u6790\u3067\u4f7f\u7528\u3057\u305f<strong>Rtx-200<\/strong>\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15059\" target=\"_blank\" rel=\"noopener\">15059<\/a>\uff09\u306f\u3001PLOT\u30ab\u30e9\u30e0\u3068\u7570\u306a\u308a<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19774\" target=\"_blank\" rel=\"noopener\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7<\/a>\u304c\u4e0d\u8981\u3067\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff08CFC\uff09\u306e\u30af\u30e9\u30a4\u30aa\u30d5\u30a9\u30fc\u30ab\u30b9\u3092\u5fc5\u8981\u3068\u305b\u305a\u306b GC-MS \u3067\u5206\u6790\u3067\u304d\u308b\u305f\u3081\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3068\u8a00\u3048\u307e\u3059\u3002\u3053\u306e\u56fa\u5b9a\u76f8\u306e\u72ec\u81ea\u306e\u9078\u629e\u6027\u306f\u3001\u4e00\u822c\u7684\u306b\u898b\u3089\u308c\u308b\u30cf\u30ed\u30b2\u30f3\u5316\u5316\u5408\u7269\u306e\u6700\u826f\u306e\u4fdd\u6301\u3068\u5206\u96e2\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:\u00a0<\/strong>Rtx-200\u30ab\u30e9\u30e0\u306f\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff08CFC\uff09\u306e\u512a\u308c\u305f\u4fdd\u6301\u3068\u5206\u96e2\u3092\u793a\u3057\u307e\u3059\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc1383.png\" alt=\"Fluorocarbons on Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC1383<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30275<\/li><li>30421<\/li><li>15059<\/li><li>23305<\/li><li>21142<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>CFC<\/li><li>chlorofluorocarbon<\/li><li>freon<\/li><li>rtx-200<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc1383.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec05\" class=\"wp-block-heading\"><a id=\"sec05\"><\/a>5. \u30af\u30ed\u30ed\u30b7\u30e9\u30f3<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30af\u30ed\u30ed\u30b7\u30e9\u30f3\u306f\u63ee\u767a\u6027\u3067\u53cd\u5fdc\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u3067\u3042\u308a\u3001\u30b7\u30ea\u30eb\u5316\u5264\u3084\u30b7\u30ea\u30b3\u30fc\u30f3\u5408\u6210\u306e\u4e2d\u9593\u4f53\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u9ad8\u3044\u53cd\u5fdc\u6027\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306fGC\u306b\u3088\u308b\u5206\u6790\u304c\u56f0\u96e3\u3067\u3059\u3002\u3057\u304b\u3057\u3001<strong>\u9577\u305560 m\u3001\u5185\u5f840.53 mm\u3001\u819c\u539a3.0 \u00b5m\u306eRtx-200\u30ab\u30e9\u30e0<\/strong>\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15088\" target=\"_blank\" rel=\"noopener\">15088<\/a>\uff09\u3092\u7528\u3044\u308b\u3068\u3001\u5e83\u7bc4\u56f2\u306e\u30af\u30ed\u30ed\u30b7\u30e9\u30f3\u5316\u5408\u7269\u306e\u5206\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059 \uff08<strong>Figure 5<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong>\u00a0\u53cd\u5fdc\u6027\u306e\u3042\u308b\u30af\u30ed\u30ed\u30b7\u30e9\u30f3\u309260 m\u306eRtx-200\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u5206\u6790\u3057\u305f\u3082\u306e\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00362.png\" alt=\"Silanes on Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CH00362<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>15088<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00362.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec06\" class=\"wp-block-heading\"><a id=\"sec06\"><\/a>6. \u6eb6\u5a92<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6eb6\u5a92\u306e\u7d14\u5ea6\u3092\u8a66\u9a13\u3057\u305f\u308a\u3001\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u304b\u3089\u306e\u6eb6\u5a92\u3092\u5206\u6790\u3059\u308b\u306b\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u7523\u696d\u7528\u6eb6\u5a92\u3092\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306b\u89e3\u6c7a\u3059\u308b\u30ab\u30e9\u30e0\u304c\u5fc5\u8981\u3067\u3059\u3002<strong>Figure 6<\/strong>\u306e\u5206\u6790\u3067\u4f7f\u7528\u3057\u305f<strong>Rtx-20<\/strong>0\u30ab\u30e9\u30e0\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15088\" target=\"_blank\" rel=\"noopener\">15088<\/a>\uff09\u306f\u4e00\u822c\u7684\u306a\u7523\u696d\u7528\u6eb6\u5a92\u306b\u304a\u3051\u308b\u3001\u5e45\u5e83\u3044\u5206\u6790\u306b\u6700\u9069\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong>\u00a0Rtx-200\u30ab\u30e9\u30e0\u306f\u5e45\u5e83\u3044\u6eb6\u5a92\u3092\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306b\u5206\u6790\u3067\u304d\u307e\u3059\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00339.png\" alt=\"Solvent Mixture #2 on Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CH00339<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>15088<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>limonene<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch00339.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec07\" class=\"wp-block-heading\"><a id=\"sec07\"><\/a>7. \u98df\u54c1\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u4e2d\u306e\u6bba\u866b\u5264 GCxGC\uff08\u4e8c\u6b21\u30ab\u30e9\u30e0\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">x\u8ef8\u3068y\u8ef8\u306b\u6cbf\u3063\u305f\u5e83\u7bc4\u56f2\u306e\u5206\u5e03\u304c\u793a\u3059\u3088\u3046\u306b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/13623\" target=\"_blank\" rel=\"noopener\">Rxi-5Sil<\/a>\u3068<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/45001\" target=\"_blank\" rel=\"noopener\">Rtx-200<\/a>\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305fGCxGC\u5206\u6790\u3067\u306f\u30012,4&#8242;-DDT\u30844,4&#8242;-DDD\u306a\u3069\u306e\u540c\u91cd\u4f53\u306e\u5316\u5408\u7269\u3092\u7c21\u5358\u306b\u5206\u96e2\u3057\u3066\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08<strong>Figure 7<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong>\u00a0Rxi-5Sil MS\u3068Rtx-200\u30ab\u30e9\u30e0\u306e\u6975\u6027\u304c\u7570\u306a\u308b\u30ab\u30e9\u30e0\u30bb\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u305f\u8fb2\u85ac\u985e\u306e\u512a\u308c\u305f\u4e8c\u6b21\u5143\u5206\u96e2\u3002Rxi-5Sil MS\u4e0a\u3067\u540c\u91cd\u4f53\u3067\u3042\u308b2,4\u2019-DDT\u30684,4\u2019-DDD\u306e2\u6b21\u5143\u5206\u96e2\u306b\u6ce8\u76ee\u3057\u3066\u304f\u3060\u3055\u3044\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1188.png\" alt=\"Pesticides in Dietary Supplements (Zoom of GCxGC-TOFMS Contour Plot)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1188<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13623<\/li><li>45001<\/li><li>20429<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>GCxGC<\/li><li>dietary supplements<\/li><li>pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1188.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec08\" class=\"wp-block-heading\"><a id=\"sec08\"><\/a><span style=\"color: #000000;\">8. \u4f4e\u5727GC-MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4f7f\u3063\u3066\u5206\u6790\u3092\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7<\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"color: #000000;\">Restek\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/11807\" target=\"_blank\" rel=\"noopener\">\u4f4e\u5727GC\uff08LPGC\uff09Rtx-200\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/a>\u306f\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u4f7f\u7528\u91cf\u3092\u7bc0\u7d04\u3057\u306a\u304c\u3089\u5927\u5e45\u306a\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002LPGC Rtx-200\u3092\u7528\u3044\u305f4\u7a2e\u985e\u306e\u4e00\u822c\u7684\u306a\u30d5\u30eb\u30aa\u30ed\u30c6\u30ed\u30de\u30fc\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u8fc5\u901f\u306a\u5206\u6790\u3067\u306f\u30014\u5206\u672a\u6e80\u3067\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u304c\u9054\u6210\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 8<\/strong>\uff09\u3002LPGC\u30e1\u30bd\u30c3\u30c9\u306f\u5f93\u6765\u306eGC-MS\u30e1\u30bd\u30c3\u30c9\u306b\u6bd4\u3079\u308b\u30681.9\u500d\u901f\u304f\u3001\u30d8\u30ea\u30a6\u30e0\u306e\u4f7f\u7528\u91cf\u306f60\uff05\u5c11\u306a\u3044\u3067\u3059\u3002<\/span><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong>\u00a0LPGC Rtx-200\u3092\u7528\u3044\u305fFTOH\u306e\u5206\u6790\u3067\u306f\u3001\u3059\u3079\u3066\u306e\u30a2\u30a4\u30bd\u30d0\u30fc\u306e\u512a\u308c\u305f\u5206\u96e2\u3092\u9054\u6210\u3057\u306a\u304c\u3089\u3001\u5927\u5e45\u306a\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u304c\u5b9f\u73fe\u3055\u308c\u307e\u3057\u305f\uff08\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1518.png\" alt=\"Fluorotelomer Alcohols on LPGC Rtx-200\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1518<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>11807<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>FTOH<\/li><li>PFAS<\/li><li>PFAS-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1518.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 id=\"sec09\" class=\"wp-block-heading\"><a id=\"sec09\"><\/a>9. Pro <em>EZ<\/em>GC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u7c21\u5358\u306b\u5206\u6790\u3092\u6700\u9069\u5316<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/15023\" target=\"_blank\" rel=\"noopener\">Rtx-200\u30ab\u30e9\u30e0<\/a>\u306f<a href=\"https:\/\/ez.restek.com\/proezgc\/ja\" target=\"_blank\" rel=\"noopener\">Pro <em>EZ<\/em>GC Chromatogram Modeler<\/a>\u306b\u3088\u3063\u3066\u30b5\u30dd\u30fc\u30c8\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u7c21\u5358\u306b\u5206\u6790\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u7121\u6599\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u305f\u3063\u305f\u6570\u5206\u3067GC\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u9069\u5316\u3068\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u884c\u3046\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002\u5b9f\u969b\u306eGC\u88c5\u7f6e\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong>\u00a0Rtx-200\u30ab\u30e9\u30e0\u306fPro\u00a0<em>EZ<\/em>GC\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e2\u30c7\u30e9\u30fc\u306b\u3088\u3063\u3066\u30b5\u30dd\u30fc\u30c8\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u7c21\u5358\u306b\u5206\u6790\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"634\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02-1024x634.jpg\" alt=\"\" class=\"wp-image-21675\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02-1024x634.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02-300x186.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02-768x476.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02-1536x951.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS4041-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306eRtx-200 GC\u30ab\u30e9\u30e0\u306e\u72ec\u81ea\u9078\u629e\u6027\u306b\u3088\u308a\u3001\u6eb6\u5a92\u3001\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u3001\u30b1\u30c8\u30f3\u3001\u30b7\u30e9\u30f3\u3001\u304a\u3088\u3073\u30b7\u30ed\u30ad\u30b5\u30f3\u306a\u3069\u306e\u6975\u6027\u5316\u5408\u7269\u306e\u512a\u308c\u305f\u4fdd\u6301\u3068\u5206\u96e2\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002Rtx-200 \u30ab\u30e9\u30e0\u306e\u72ec\u7279\u306e\u6975\u6027\u306b\u3088\u308a\u3001\u975e\u6975\u6027\u30ab\u30e9\u30e0\u3084\u6975\u6027\u30ab\u30e9\u30e0\u3067\u306f\u9054\u6210\u3067\u304d\u306a\u3044\u5206\u96e2\u304c\u78ba\u5b9f\u306b\u884c\u308f\u308c\u308b\u305f\u3081\u3001\u5e45\u5e83\u3044\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7464,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-43853","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS4041-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43853"}],"version-history":[{"count":21,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43853\/revisions"}],"predecessor-version":[{"id":100171,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43853\/revisions\/100171"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7464"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43853"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43853"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43853"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43853"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43853"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43853"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43853"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43853"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}