{"id":43872,"date":"2020-10-28T00:00:00","date_gmt":"2020-10-28T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-molecular-sieve-5a-and-13x-packed-gc-columns-for-permanent-gas-separations\/"},"modified":"2026-04-07T01:55:46","modified_gmt":"2026-04-07T01:55:46","slug":"japanese-molecular-sieve-5a-and-13x-packed-gc-columns-for-permanent-gas-separations","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/pcar2969-ja\/japanese-molecular-sieve-5a-and-13x-packed-gc-columns-for-permanent-gas-separations","title":{"rendered":"\u6c38\u4e45\u30ac\u30b9\u306e\u5206\u96e2\u306b\u9069\u3057\u305f\u30d1\u30c3\u30af\u30c9GC\u30ab\u30e9\u30e0\u3000\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A, 13X"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5408\u6210\u30bc\u30aa\u30e9\u30a4\u30c8\u306e\u5145\u586b\u5264\u3067\u3042\u308b\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u306f\u30011950\u5e74\u4ee3\u304b\u3089\u8efd\u8cea\u30ac\u30b9\uff08\u9178\u7d20\u3001\u7a92\u7d20\u3001\u30e1\u30bf\u30f3\u3001\u4e00\u9178\u5316\u70ad\u7d20\uff09\u3068\u4e0d\u6d3b\u6027\u30ac\u30b9\uff08\u30d8\u30ea\u30a6\u30e0\u3001\u30a2\u30eb\u30b4\u30f3\u3001\u30cd\u30aa\u30f3\u3001\u30af\u30ea\u30d7\u30c8\u30f3\u3001\u30ad\u30bb\u30ce\u30f3\uff09\u306e\u5206\u96e2\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u57fa\u672c\u7684\u306a\u69cb\u9020\u3084\u6027\u80fd\u306b\u306f\u308f\u305a\u304b\u306a\u5909\u66f4\u3084\u6539\u5584\u3057\u304b\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306f\u3001\u6700\u3082\u4e00\u822c\u7684\u306a2\u3064\u306e\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u3067\u3042\u308b5A\u306813X\u3092\u3001\u30d0\u30c3\u30c1\u9593\u306e\u4e0d\u6d3b\u6027\u3055\u3068\u4e00\u8cab\u6027\u3092\u5099\u3048\u305f\u9ad8\u6027\u80fd\u5145\u586b\u5264\u3068\u3057\u3066\u8a2d\u8a08\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5145\u586b\u5264\u306f\u3001\u5e45\u5e83\u3044\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u304a\u3088\u3073PLOT\u30ab\u30e9\u30e0\u5206\u6790\u3067\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u306813X\u306e\u5145\u586b\u5264\u306f\u7d30\u5b54\u5f84\u3068\u69cb\u9020\u304c\u7570\u306a\u308b\u305f\u3081\u3001\u591a\u304f\u306e\u30ac\u30b9\u3067\u4fdd\u6301\u3068\u9078\u629e\u6027\u306b\u9055\u3044\u304c\u751f\u3058\u307e\u3059\u3002\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u306f\u4fdd\u6301\u529b\u304c\u9ad8\u304f\u3001\u30a2\u30eb\u30b4\u30f3\u3001\u9178\u7d20\u3001\u7a92\u7d20\u306e\u5206\u96e2\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u534a\u5c0e\u4f53\u696d\u754c\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u4e0d\u6d3b\u6027\u30ac\u30b9\u4e2d\u306e\u5fae\u91cf\u4e0d\u7d14\u7269\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d613X\u306f\u3001\u7279\u306b\u5fae\u91cf\u6fc3\u5ea6\u306e\u4e00\u9178\u5316\u70ad\u7d20\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u6eb6\u51fa\u304c\u65e9\u3044\u307b\u3069\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306e\u30d4\u30fc\u30af\u304c\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308a\u3001\u691c\u51fa\u9650\u754c\u304c\u5411\u4e0a\u3059\u308b\u305f\u3081\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Silcosteel\u51e6\u7406\u3057\u305f\u30c1\u30e5\u30fc\u30d6\u306b\u5145\u586b\u3055\u308c\u305f\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u307e\u305f\u306f13X\u306f\u3001\u6c38\u4e45\u30ac\u30b9\u5206\u6790\u306b\u5bfe\u3057\u3066\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u3092\u767a\u63ee<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1<\/strong>\u3067\u306f\u30011\u30e1\u30fc\u30c8\u30eb\u306e\u9ad8\u6027\u80fd\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u30ab\u30e9\u30e0\u30682\u30e1\u30fc\u30c8\u30eb\u306e\u9ad8\u6027\u80fd\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d613X\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u6df7\u5408\u30ac\u30b9\u5206\u6790\u3092\u6bd4\u8f03\u3057\u3066\u3044\u307e\u3059\u3002\u5404\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u4e00\u9178\u5316\u70ad\u7d20\u306e\u512a\u308c\u305f\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306b\u6ce8\u76ee\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u306f\u3001\u5145\u586b\u5264\u3068\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\u304c\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u54c1\u8cea\u306e\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u3068Silcosteel\u51e6\u7406\u3055\u308c\u305f\u30c1\u30e5\u30fc\u30d6\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u9178\u7d20\u3068\u4e00\u9178\u5316\u70ad\u7d20\u3068\u3044\u3046\u5fae\u91cf\u5206\u6790\u304c\u96e3\u3057\u3044\u6210\u5206\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1\uff1a<\/strong>\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u304a\u3088\u3073\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d613X\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u6c38\u4e45\u30ac\u30b9\u5206\u6790\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc00166.png\" alt=\"Permanent Gases on Molecular Sieve 5A and Molecular Sieve 13X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC00166<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>80440-800<\/li><li>80439-800<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Gases<\/li><li>Molecular<\/li><li>Permanent<\/li><li>Sieve<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc00166.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u54c1\u8cea\u30c6\u30b9\u30c8\u306b\u3088\u308b\u518d\u73fe\u6027\u306e\u78ba\u4fdd<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u9178\u5316\u70ad\u7d20\u306a\u3069\u306e\u5fae\u91cf\u30ac\u30b9\u3092\u5438\u7740\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u91d1\u5c5e\u3084\u305d\u306e\u4ed6\u306e\u5fae\u91cf\u6c5a\u67d3\u7269\u8cea\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u3001\u30bc\u30aa\u30e9\u30a4\u30c8\u5145\u586b\u5264\u306e\u5404\u30ed\u30c3\u30c8\u3092\u7cbe\u88fd\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u3059\u3079\u3066\u306e\u30d0\u30c3\u30c1\u3092\u7cbe\u5bc6\u306a\u30e1\u30c3\u30b7\u30e5\u7bc4\u56f2\u306b\u5206\u7d1a\u3057\u3066\u3001\u30ed\u30c3\u30c8\u9593\u306e\u518d\u73fe\u6027\u304c\u78ba\u4fdd\u3055\u308c\u307e\u3059\u3002\u30b5\u30fc\u30de\u30eb\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u30d7\u30ed\u30bb\u30b9\u306f\u3001\u30e1\u30bf\u30f3\/\u4e00\u9178\u5316\u70ad\u7d20\u306e\u76f8\u5bfe\u7684\u306a\u4fdd\u6301\u3092\u78ba\u7acb\u3057\u3001\u4e00\u9178\u5316\u70ad\u7d20\u306e\u3088\u3046\u306a\u6d3b\u6027\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u512a\u308c\u305f\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3092\u751f\u307f\u51fa\u3059\u305f\u3081\u306b\u91cd\u8981\u3067\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u306f\u30ed\u30c3\u30c8\u6bce\u306b\u7cbe\u5bc6\u306b\u88fd\u9020\u3001\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3055\u308c\u3001\u54c1\u8cea\u30c6\u30b9\u30c8\u3092\u53d7\u3051\u307e\u3059\u3002\u54c1\u8cea\u30c6\u30b9\u30c8\u3067\u306f\u3001\u6c38\u4e45\u30ac\u30b9\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u30c6\u30b9\u30c8\u30df\u30c3\u30af\u30b9\u3092\u7528\u3044\u3066\u3001\u30ab\u30e9\u30e0\u52b9\u7387\u306e\u518d\u73fe\u6027\u3001\u30ab\u30e9\u30e0\u80cc\u5727\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3084\u76f8\u5bfe\u4fdd\u6301\u6642\u9593\u3092\u78ba\u8a8d\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u3067\u306f\u3001\u9178\u7d20\u3084\u4e00\u9178\u5316\u70ad\u7d20\u306a\u3069\u306e\u5fae\u91cf\u96e3\u89e3\u7269\u306e\u5206\u6790\u306e\u305f\u3081\u3001\u30d1\u30c3\u30af\u30c9GC\u30ab\u30e9\u30e0 \u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u304a\u3088\u307313X \u3092\u6d3b\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u306f\u4e0d\u63ee\u767a\u6027\u30ac\u30b9\u306b\u5bfe\u3059\u308b\u5bfe\u79f0\u30d4\u30fc\u30af\u304c\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":70629,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2270],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-43872","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-energy-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2270,"label":"\u30a8\u30cd\u30eb\u30ae\u30fc"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-PCAR2969-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43872"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43872\/revisions"}],"predecessor-version":[{"id":92228,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43872\/revisions\/92228"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/70629"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43872"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43872"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43872"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43872"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43872"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43872"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}