{"id":43886,"date":"2020-10-22T00:00:00","date_gmt":"2020-10-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/packed-and-micropacked-column-information-japan\/"},"modified":"2026-04-07T01:26:15","modified_gmt":"2026-04-07T01:26:15","slug":"packed-and-micropacked-column-information-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/pcot3225-ja\/packed-and-micropacked-column-information-japan","title":{"rendered":"\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\/\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u30a4\u30f3\u30d5\u30a9\u30e1\u30fc\u30b7\u30e7\u30f3"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u30e1\u30bd\u30c3\u30c9\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u76ee\u7684\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u305f\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u7279\u5b9a\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u306b\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u88fd\u54c1\u4ed5\u69d8\u306a\u3069\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u30ab\u30e9\u30e0\u540d\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30ab\u30e9\u30e0<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u7279\u5fb4<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\">\u30e1\u30ea\u30c3\u30c8<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">ASTM Method D3606<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/p\/83606-800\" target=\"_blank\" rel=\"noreferrer noopener\">D3606 Application Column Set<\/a> <br>Column 1: Backflush column, 6&#8242; (1.8 m), 1\/8&#8243; OD, 2.0 mm ID; Column 2: proprietary packing, 15.5&#8242; (4.7 m), 1\/8&#8243; OD, 2.0 mm ID<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a8\u30bf\u30ce\u30fc\u30eb\u3068\u30d9\u30f3\u30bc\u30f3\u306e\u512a\u308c\u305f\u5206\u96e2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e1\u30bd\u30c3\u30c9\u306e\u8981\u4ef6\u306b\u78ba\u5b9f\u306b\u6e96\u62e0\u3057\u307e\u3059\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30ea\u30d5\u30a1\u30a4\u30ca\u30ea\u30ac\u30b9<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/p\/88000-810\" target=\"_blank\" rel=\"noopener\">2abc Refinery Gas Column Set<\/a><br><br><a href=\"https:\/\/www.restek.com\/p\/88004-875\" target=\"_blank\" rel=\"noopener\">Backflush Column<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6700\u9069\u306a3\u30ab\u30e9\u30e0\u30bb\u30c3\u30c8\uff08\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u30ab\u30e9\u30e0\u306f\u5225\u58f2\u308a\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">C5\u70ad\u5316\u6c34\u7d20\u3092C1-C4\u70ad\u5316\u6c34\u7d20\u3088\u308a\u3082\u5148\u306b\u6eb6\u51fa\u3055\u305b\u3001\u6700\u9069\u306a\u5206\u96e2\u3092\u5f97\u307e\u3059\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u98fd\u548c\u8efd\u8cea\u70ad\u5316\u6c34\u7d20<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/p\/80436-800\" target=\"_blank\" rel=\"noopener\"><em>n<\/em>-Octane on Res-Sil C Column<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u98fd\u548c\u70ad\u5316\u6c34\u7d20\u306b\u5bfe\u3059\u308b\u72ec\u81ea\u306e\u9078\u629e\u6027<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4e0d\u98fd\u548c\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\u306e\u512a\u308c\u305f\u5206\u96e2\u306b\u3088\u308a\u30c7\u30fc\u30bf\u306e\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><em>cis<\/em>-2-Butene and 1,3-Butadiene<\/td><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/p\/80437-800\" target=\"_blank\" rel=\"noopener\">OPN on Res-Sil C Column<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>cis<\/em>-2-Butene\u30681,3-Butadiene\u306e\u5206\u96e2\u306b\u6700\u9069\u306a\u9078\u629e\u6027<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c7\u30fc\u30bf\u306e\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6c38\u4e45\u30ac\u30b9<\/td><td class=\"has-text-align-left\" data-align=\"left\">ShinCarbon ST Columns<br><a href=\"https:\/\/www.restek.com\/p\/80486-800\" target=\"_blank\" rel=\"noopener\">Packed<\/a>&nbsp;\/ <a href=\"https:\/\/www.restek.com\/p\/19043\" target=\"_blank\" rel=\"noopener\">Micropacked<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30af\u30e9\u30a4\u30d5\u30a9\u30fc\u30ab\u30b7\u30f3\u30b0\u306a\u3057\u3067\u306e\u5e38\u6e29\u30ac\u30b9\u306e\u5206\u96e2\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u9078\u629e\u6027 \u30ab\u30e9\u30e0\u306f\u4e8b\u524d\u306b\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30f3\u30b0\u6e08\u307f<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u751f\u7523\u6027\u3092\u5411\u4e0a\u3055\u305b\u307e\u3059\u3002<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u6fc3\u5ea6\u786b\u9ec4<\/td><td class=\"has-text-align-left\" data-align=\"left\">Rt-XLSulfur Columns<br><a href=\"https:\/\/www.restek.com\/p\/80484-800\" target=\"_blank\" rel=\"noopener\">Packed&nbsp;<\/a>\/ <a href=\"https:\/\/www.restek.com\/p\/19044\" target=\"_blank\" rel=\"noopener\">Micropacked<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u786b\u9ec4\u306eppbv\u30ec\u30d9\u30eb\u306b\u5bfe\u3057\u3066\u975e\u5e38\u306b\u4e0d\u6d3b\u6027 PTFE\u30c1\u30e5\u30fc\u30d6\u304c\u4e0d\u8981<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u4f4e\u30ec\u30d9\u30eb\u306e\u786b\u9ec4\u5206\u6790\u306e\u30c7\u30fc\u30bf\u7cbe\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u7279\u5225\u306aGC\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u304c\u4e0d\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u4ee5\u4e0b\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u304b\u3089\u3001\u304a\u4f7f\u3044\u306e\u6a5f\u5668\u306b\u9069\u3057\u305f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u69cb\u6210\u3092\u9078\u629e\u3057\u3001\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u306e\u672b\u5c3e\u306b\u5bfe\u5fdc\u3059\u308b\u30b5\u30d5\u30a3\u30c3\u30af\u30b9\u756a\u53f7\u3092\u8ffd\u52a0\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\uff08\u306a\u304a\u3001\u5c0f\u53e3\u5f84\u30ab\u30e9\u30e0[\u5916\u5f841\/16\u30a4\u30f3\u30c1\u4ee5\u4e0b]\u306b\u306f\u30b5\u30d5\u30a3\u30c3\u30af\u30b9\u756a\u53f7\u306f\u4e0d\u8981\u3067\u3059\u3002\uff09<\/em><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30b5\u30d5\u30a3\u30c3\u30af\u30b9<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u69cb\u6210<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">-800<\/td><td class=\"has-text-align-left\" data-align=\"left\">General<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-810<\/td><td class=\"has-text-align-left\" data-align=\"left\">Agilent Standard<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-811<\/td><td class=\"has-text-align-left\" data-align=\"left\">Agilent 6850<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-820<\/td><td class=\"has-text-align-left\" data-align=\"left\">Varian Standard<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-821<\/td><td class=\"has-text-align-left\" data-align=\"left\">Varian 3800<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-830<\/td><td class=\"has-text-align-left\" data-align=\"left\">PE 900-3920; Sigma 1,2,3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-840<\/td><td class=\"has-text-align-left\" data-align=\"left\">PE Standard<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-845<\/td><td class=\"has-text-align-left\" data-align=\"left\">ABB<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-850<\/td><td class=\"has-text-align-left\" data-align=\"left\">Shimadzu 14A, 2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-851<\/td><td class=\"has-text-align-left\" data-align=\"left\">Shimadzu 8A<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-853<\/td><td class=\"has-text-align-left\" data-align=\"left\">Shimadzu 17A, 2010<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-860<\/td><td class=\"has-text-align-left\" data-align=\"left\">Thermo TRACE 2000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-875<\/td><td class=\"has-text-align-left\" data-align=\"left\">Analytical Controls<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-890<\/td><td class=\"has-text-align-left\" data-align=\"left\">Gow Mac 590<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-891<\/td><td class=\"has-text-align-left\" data-align=\"left\">Gow Mac 550<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-893<\/td><td class=\"has-text-align-left\" data-align=\"left\">Gow Mac 816<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">-895<\/td><td class=\"has-text-align-left\" data-align=\"left\">SRI 8610C<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u793e\u306e\u30ab\u30e9\u30e0\u306b\u3054\u4f7f\u7528\u3044\u305f\u3060\u3051\u308b\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0 \u30ad\u30c3\u30c8\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30aa\u30d7\u30b7\u30e7\u30f3*<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u8aac\u660e<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit 1S<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; Brass Nuts,<br>1\/4&#8243; to 1\/8&#8243; V\/G Reducing Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit 2S<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; Brass Nuts,<br>1\/4&#8243; to 3\/16&#8243; V\/G Reducing Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit A<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; Brass Nuts,<br>1\/8&#8243; V\/G Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit B<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; Brass Nuts,<br>1\/8&#8243; Brass Front &amp; Back Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit B2<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; Brass Nuts,<br>1\/4&#8243; Brass Front &amp; Back Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit C<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; SS Nuts,<br>1\/8&#8243; SS Front &amp; Back Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit D<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; SS Nuts,<br>1\/8&#8243; V\/G Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit E<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; SS Nuts,<br>1\/4&#8243; to 1\/8&#8243; V\/G Reducing Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit F<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; SS Nuts,<br>1\/4&#8243; to 3\/16&#8243; V\/G Reducing Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit G<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/4&#8243; SS Nuts,<br>1\/4&#8243; V\/G Ferrules<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit VNICKEL<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; VCR fittings (Nickel)<br>(Silver soldered onto the column)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Kit VSS<\/td><td class=\"has-text-align-left\" data-align=\"left\">Fitting Kit: 1\/8&#8243; VCR fitting (SS)<br>(Silver soldered onto the column)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Preconditioning<\/td><td class=\"has-text-align-left\" data-align=\"left\">Optional for each finished column<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u4e00\u90e8\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u306f\u8ffd\u52a0\u8cbb\u7528\u304c\u304b\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/83606-800\">                                \u30ab\u30bf\u30ed\u30b0No. 83606-800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0 \u30bb\u30c3\u30c8\uff5cASTM D3606\u5bfe\u5fdc\u30ac\u30bd\u30ea\u30f3\u4e2d\u30d9\u30f3\u30bc\u30f3\u30fb\u30c8\u30eb\u30a8\u30f3\u5206\u6790\u7528<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/83606-800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/88000-810\">                                \u30ab\u30bf\u30ed\u30b0No. 88000-810                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Packed GC Column, 2abc Refinery Gas Column Set on Silcosteel Tubing, Configuration for Agilent<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/88000-810\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/88004-875\">                                \u30ab\u30bf\u30ed\u30b0No. 88004-875                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Packed GC Column, 2.1% Carbowax 1540 Porasil C, 80\/100, 2&#039;, 2 mm ID, NOC, AC<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/88004-875\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80436-800\">                                \u30ab\u30bf\u30ed\u30b0No. 80436-800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Packed GC Column, n-Octane on Res-Sil C, 80\/100, 20&#039;, 2 mm ID, 1\/8&quot; OD<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80436-800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80437-800\">                                \u30ab\u30bf\u30ed\u30b0No. 80437-800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">OPN on Res-Sil C Packed GC Column, 80\/100, 12&#039;, 2 mm ID, 1\/8&quot; OD, General Configuration<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80437-800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80486-800\">                                \u30ab\u30bf\u30ed\u30b0No. 80486-800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">ShinCarbon ST Packed GC Column, 80\/100, 2 m, 2 mm ID, 1\/8&quot; OD, Silco, General Configuration<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80486-800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19043\">                                \u30ab\u30bf\u30ed\u30b0No. 19043                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">ShinCarbon ST Micropacked GC Column, 80\/100, 2 m, 0.53 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19043\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80484-800\">                                \u30ab\u30bf\u30ed\u30b0No. 80484-800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rt-XLSulfur Packed GC Column, 100\/120, 1 m, 2.0 mm ID, 1\/8&quot; OD, General Configuration<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/80484-800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19044\">                                \u30ab\u30bf\u30ed\u30b0No. 19044                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rt-XLSulfur Micropacked GC Column, 100\/120, 2 m, 0.53 mm ID, 0.74 mm OD<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19044\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u3042\u306a\u305f\u304c\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u306e\u7279\u5fb4\u3084\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u4e00\u89a7\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2270],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[2814],"class_list":["post-43886","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-energy-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2270,"label":"\u30a8\u30cd\u30eb\u30ae\u30fc"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43886","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43886"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43886\/revisions"}],"predecessor-version":[{"id":92221,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43886\/revisions\/92221"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43886"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43886"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43886"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43886"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43886"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43886"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43886"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43886"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43886"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}