{"id":43889,"date":"2020-11-01T13:30:00","date_gmt":"2020-11-01T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/resteks-plot-column-family-japan\/"},"modified":"2026-04-07T01:36:45","modified_gmt":"2026-04-07T01:36:45","slug":"resteks-plot-column-family-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/pcss1163-ja\/resteks-plot-column-family-japan","title":{"rendered":"Restek PLOT\u30ab\u30e9\u30e0\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u3000\u305d\u306e\u7279\u5fb4\u3068\u72ec\u81ea\u6280\u8853"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u65b0\u57fa\u6e96\uff01<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7c92\u5b50\u5265\u96e2\u3092\u5927\u5e45\u524a\u6e1b\u3059\u308b\u9769\u65b0\u7684\u306a\u7d50\u5408\u5de5\u7a0b<\/li>\n\n\n\n<li>\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3092\u5b9f\u73fe\u3059\u308b\u4e00\u8cab\u6027\u3042\u308b\u30d5\u30ed\u30fc<\/li>\n\n\n\n<li>\u4e0d\u7d14\u7269\u5206\u6790\u306e\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u308b\u512a\u308c\u305f\u30d4\u30fc\u30af\u5bfe\u79f0\u6027<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-medium-font-size wp-block-paragraph\">PLOT\u30ab\u30e9\u30e0\u306e\u7121\u6599\u30e1\u30bd\u30c3\u30c9\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3<a href=\"https:\/\/ez.restek.com\/proezgc\/en\/ja\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Restek PLOT\u30ab\u30e9\u30e0\u306e\u5229\u70b9<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7c92\u5b50\u5c64\u306e\u5b89\u5b9a\u5316\u3067\u3001\u5805\u7262\u6027\u3001\u4fdd\u6301\u6642\u9593\u3001\u30d5\u30ed\u30fc\u306e\u518d\u73fe\u6027\u304c\u5411\u4e0a<\/li>\n\n\n\n<li>\u9ad8\u52b9\u7387\u3067\u518d\u73fe\u6027\u306e\u9ad8\u3044\u5206\u6790\u3092\u5b9f\u73fe\uff08\u6c38\u4e45\u30ac\u30b9\u3001\u6eb6\u5a92\u3001\u70ad\u5316\u6c34\u7d20\u306e\u5206\u6790\u306b\u6700\u9069\uff09<\/li>\n\n\n\n<li>\u9769\u65b0\u7684\u306a\u88fd\u9020\u5de5\u7a0b\u3067\u7c92\u5b50\u767a\u751f\u3092\u4f4e\u6e1b\u3057\u3001PLOT\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u304c\u5411\u4e0a<\/li>\n\n\n\n<li>\u76f4\u5f847\u30a4\u30f3\u30c1\u30fb11\u30d4\u30f3\u30b1\u30fc\u30b8\u306e\u5dfb\u304d\u304c\u6a19\u6e96\uff08\u7570\u306a\u308b\u5834\u5408\u306f\u8a18\u8f09\u3042\u308a\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u8ab2\u984c\u89e3\u6c7a\u306bPLOT\uff08Porous Layer Open Tubular\uff09\u30ab\u30e9\u30e0\u306f\u9069\u4efb\u3067\u3059\u3002\u305d\u306e\u7406\u7531\u306f\u4e8c\u3064\u2026PLOT\u30ab\u30e9\u30e0\u306f\u3001\u2460\u72ec\u81ea\u306e\u9078\u629e\u6027\uff08\u63ee\u767a\u6027\u5316\u5408\u7269\u3092\u5ba4\u6e29\u3067\u5206\u96e2\u53ef\u80fd\uff09\u3068\u2461\u56fa\u5b9a\u76f8\u306e\u5438\u7740\u6a5f\u69cb\uff08\u6c38\u4e45\u30ac\u30b9\u3084\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\u3092\u5ba4\u6e29\u3067\u5206\u96e2\u53ef\u80fd\uff09\u3092\u6301\u3063\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u307e\u305f\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u5ba4\u6e29\u4ee5\u4e0a\u306b\u4e0a\u6607\u3055\u305b\u3066\u3044\u3051\u3070\u3001\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u3092\u6eb6\u51fa\u3055\u305b\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5f93\u6765\u578bPLOT\u30ab\u30e9\u30e0\u306e\u8ab2\u984c\uff1a\u5b89\u5b9a\u6027\u306e\u4f4e\u3055<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ed6\u793e\u5f93\u6765\u578bPLOT\u30ab\u30e9\u30e0\u3067\u306f\u30015\uff5e50 \u03bcm\u306e\u7c92\u5b50\u5c64\u304c\u4e0d\u5b89\u5b9a\u306a\u307e\u307e\u5185\u58c1\u306b\u4ed8\u7740\u3057\u3066\u304a\u308a\u3001\u4f7f\u7528\u4e2d\u306e\u5265\u96e2\u306b\u3088\u3063\u3066\u4fdd\u6301\u6642\u9593\u3084\u30d5\u30ed\u30fc\u304c\u5927\u304d\u304f\u4e71\u308c\u307e\u3059\u3002\u30d0\u30eb\u30d6\u3084\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u306e\u8a70\u307e\u308a\u3001GC\u691c\u51fa\u5668\u306e\u96fb\u5b50\u30ce\u30a4\u30ba\u306a\u3069\u3001\u6df1\u523b\u306a\u5206\u6790\u969c\u5bb3\u304c\u983b\u767a\u3057\u307e\u3059\u3002<strong>Figure 1<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u306b\u7c92\u5b50\u304c\u84c4\u7a4d\u3057\u3001\u8a70\u307e\u308a\u3092\u5f15\u304d\u8d77\u3053\u3059\u73fe\u8c61\u306f\u4ed6\u793e\u88fd\u54c1\u3067\u4e00\u822c\u7684\u306b\u898b\u3089\u308c\u308b\u554f\u984c\u3067\u3059\u3002\u3053\u308c\u3092\u9632\u3050\u306b\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1179\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7<\/a>\u3068\u306e\u4f75\u7528\u304c\u5fc5\u9808\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u5f93\u6765\u578bPLOT\u30ab\u30e9\u30e0\u304b\u3089\u5265\u96e2\u3057\u305f\u7c92\u5b50\u306b\u3088\u308b\u8a70\u307e\u308a<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCSS1163G-01.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Restek PLOT\u30ab\u30e9\u30e0\uff1a\u7c92\u5b50\u5265\u96e2\u3092\u524a\u6e1b\u3059\u308b\u9769\u65b0\u7684\u306a\u5b89\u5b9a\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306fPLOT\u30ab\u30e9\u30e0\u6280\u8853\u306b\u304a\u3044\u3066\u3001\u696d\u754c\u3092\u30ea\u30fc\u30c9\u3059\u308b\u9769\u65b0\u7684\u306a\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\u3002\u5b89\u5b9a\u6027\u306e\u9ad8\u3044\u5438\u7740\u5c64\u304c\u5f62\u6210\u3055\u308c\u308b\u3053\u3068\u3067\u3001\u7c92\u5b50\u5265\u96e2\u306f\u5b9f\u8cea\u7684\u306b\u6392\u9664\u3055\u308c\u3066\u3044\u307e\u3059*\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u5bff\u547d\u304c\u5ef6\u3073\u3001\u30b9\u30d1\u30a4\u30af\u306e\u767a\u751f\u3082\u307b\u307c\u7686\u7121\u306b\u306a\u308a\u307e\u3057\u305f\u3002Restek\u88fdPLOT\u30ab\u30e9\u30e0\u306f\u3059\u3079\u3066\u3001\u540c\u6280\u8853\u306b\u3088\u3063\u3066\u88fd\u9020\u3055\u308c\u3066\u304a\u308a\u3001\u518d\u73fe\u6027\u306b\u512a\u308c\u305f\u4fdd\u6301\u6642\u9593\u3068\u30b9\u30e0\u30fc\u30ba\u306a\u30ac\u30b9\u30d5\u30ed\u30fc\u3092\u4e00\u8cab\u3057\u3066\u4fdd\u8a3c\u3057\u307e\u3059\u3002\u64cd\u4f5c\u6027\u3068\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u54c1\u8cea\u306e\u4e21\u9762\u3067\u3001\u4ed6\u793e\u88fd\u54c1\u3068\u306e\u4e00\u7dda\u3092\u753b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306f\u5f15\u304d\u7d9a\u304d\u63a8\u5968\u3055\u308c\u307e\u3059\u304c\u3001Restek\u30ab\u30e9\u30e0\u3067\u306f\u305d\u306e\u5fc5\u8981\u6027\u304c\u5927\u5e45\u306b\u4f4e\u6e1b\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u9ad8\u3044\u30d5\u30ed\u30fc\u518d\u73fe\u6027\u3092\u4fdd\u8a3c\u3059\u308b\u4e00\u8cab\u6027\u3042\u308b\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f93\u6765\u578b\uff08\u4ed6\u793e\uff09\u30ab\u30e9\u30e0\u306f\u3001\u7c92\u5b50\u5c64\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u539a\u306b\u3070\u3089\u3064\u304d\u304c\u3042\u308a\u3001\u5206\u6790\u7d50\u679c\u306e\u518d\u73fe\u6027\u306b\u6df1\u523b\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u7279\u306bDeans\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u306a\u3069\u30d5\u30ed\u30fc\u304c\u91cd\u8981\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u3001\u4fe1\u983c\u6027\u306e\u6b20\u5982\u304c\u9855\u8457\u3067\u3059\u3002<strong>Figure 2<\/strong>\u306f\u3001\u5f93\u6765\u578b\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u30d5\u30ed\u30fc\u4e0d\u5747\u4e00\u306e\u5178\u578b\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002\u5f93\u6765\u578bPLOT\u30ab\u30e9\u30e0\u306fWCOT\uff08Wall Coated Open Tublar\uff09\u30ab\u30e9\u30e0\u306b\u6bd4\u3079\u3066\u3070\u3089\u3064\u304d\u3082\u5927\u304d\u304f\u3001\u540c\u3058\u30b5\u30a4\u30ba\u3001\u540c\u3058\u5727\u529b\u6761\u4ef6\u4e0b\u3067\u3042\u3063\u3066\u3082\u30d5\u30ed\u30fc\u304c4\uff5e6\u500d\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u30d5\u30ed\u30fc\u306e\u5927\u304d\u306a\u3070\u3089\u3064\u304d\u306e\u539f\u56e0\u3068\u306a\u308b\u4e0d\u5747\u4e00\u306a\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u539a\u3055<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCSS1163G-02.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u6d41\u91cf\u62b5\u6297\u3068\u518d\u73fe\u6027\u306e\u65b0\u6307\u6a19\uff1a\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306f\u696d\u754c\u306b\u5148\u99c6\u3051\u3001\u72ec\u81ea\u306e\u54c1\u8cea\u7ba1\u7406\u6307\u6a19\u300c\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\uff09\u300d\u3092\u5c0e\u5165\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u30ab\u30e9\u30e0\u306e\u6d41\u91cf\u5747\u4e00\u6027\u3068\u6027\u80fd\u306e\u5b89\u5b9a\u6027\u3092\u53ef\u8996\u5316\u3059\u308b\u65b0\u305f\u306a\u57fa\u6e96\u3067\u3059\u3002\u3053\u306e\u4fc2\u6570\u306f\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3042\u308a\u306e\u30ab\u30e9\u30e0\u3068\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306a\u3057\u306e\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u3001\u540c\u4e00\u80cc\u5727\u6761\u4ef6\u4e0b\u3067\u6e2c\u5b9a\u3055\u308c\u305f\u3001\u4fdd\u6301\u3055\u308c\u306a\u3044\u30de\u30fc\u30ab\u30fc\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u3092\u4f7f\u3063\u3066\u8a08\u7b97\u3055\u308c\u307e\u3059\uff08<strong>Equation 1<\/strong>\uff09\u3002\u54c1\u8cea\u7ba1\u7406\u3092\u76ee\u7684\u3068\u3057\u3066\u3001\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u306e\u8a55\u4fa1\u306b\u306f\u30e1\u30bf\u30f3\u3092\u3001\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A\u30ab\u30e9\u30e0\u306e\u8a55\u4fa1\u306b\u306f\u30d8\u30ea\u30a6\u30e0\u3092\u30de\u30fc\u30ab\u30fc\u5316\u5408\u7269\u3068\u3057\u3066\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 3<\/strong>\u3067\u306f\u4ed6\u793e\u88fdPLOT\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u3070\u3089\u3064\u304d\u3092\u3001<strong>Figure 4<\/strong>\u3067\u306fRestek <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-QS-BOND<\/a>\uff08\u7d50\u5408\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\uff09PLOT\u30ab\u30e9\u30e0\u306e\u5727\u5012\u7684\u306a\u4e00\u8cab\u6027\u3092\u6bd4\u8f03\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5747\u8cea\u306a\u6027\u80fd\u306f\u3001\u6d41\u91cf\u5909\u52d5\u304c\u8a31\u3055\u308c\u306a\u3044\u5206\u6790\u73fe\u5834\u3067\u306e\u4fe1\u983c\u6027\u3092\u7d04\u675f\u3057\u307e\u3059\u3002\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\u306f\u3001\u3059\u3079\u3066\u306eRestek PLOT\u30ab\u30e9\u30e0\u306b\u4ed8\u5c5e\u3059\u308b\u5206\u6790\u8a3c\u660e\u66f8\uff08CofA\uff09\u306b\u660e\u8a18\u3055\u308c\u3066\u304a\u308a\u3001\u4e00\u89a7\u8868\u306f\u5831\u544a\u66f8\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> \u5f93\u6765\u578bPLOT\u30ab\u30e9\u30e0\u306f\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u539a\u3055\u306b\u4e00\u8cab\u6027\u304c\u306a\u304f\u3001\u30d5\u30ed\u30fc\u306e\u3070\u3089\u3064\u304d\u304c\u5927\u304d\u3044<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCSS1163G-03.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Equation 1:<\/strong>\u00a0\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\uff09\u306f\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u5747\u4e00\u6027\u3092\u793a\u3059\u6307\u6a19<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-PCSS1163G-01.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff1aF\u5024\u306f\u5e38\u306b1\u672a\u6e80\u3067\u3059\u3002\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3042\u308a\u306e\u30ab\u30e9\u30e0\u306f\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306a\u3057\u306e\u30ab\u30e9\u30e0\u3088\u308a\u3082\u5fc5\u305a\u6d41\u91cf\u62b5\u6297\u304c\u5927\u304d\u3044\u305f\u3081\u3067\u3059\u3002<\/p>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> Restek PLOT\u30ab\u30e9\u30e0\u306f\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\u306b\u4e00\u8cab\u6027\u304c\u3042\u308a\u3001\u30ab\u30e9\u30e0\u9593\u3067\u306e\u518d\u73fe\u6027\u304c\u9ad8\u3044<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-PCSS1163G-04.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Restek PLOT\u30ab\u30e9\u30e0\u306e\u7279\u9577<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PLOT\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u5805\u7262\u306a\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u3068\u9ad8\u5ea6\u306a\u5b89\u5b9a\u6027\u306b\u3088\u3063\u3066\u3001\u7af6\u5408\u4ed6\u793e\u3068\u660e\u78ba\u306b\u5dee\u5225\u5316\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6c38\u4e45\u30ac\u30b9\u3001\u70ad\u5316\u6c34\u7d20\u3001\u6eb6\u5264\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3068\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u307e\u3055\u306b\u4fe1\u983c\u3068\u5b9f\u7e3e\u306e\u8c61\u5fb4\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PLOT\u30ab\u30e9\u30e0 \u56fa\u5b9a\u76f8\u76f8\u4e92\u53c2\u7167\uff1a\u985e\u4f3c\u9078\u629e\u6027<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th><strong>Restek Rt and MXT \u30ab\u30e9\u30e0<\/strong><\/th><th><strong>\u591a\u5b54\u8cea\u5c64<\/strong><\/th><th><strong>Supelco<\/strong><\/th><th><strong>Alltech<\/strong><\/th><th><strong>Agilent (J&amp;W, Varian, Chrompack)<\/strong><\/th><th><strong>Quadrex<\/strong><\/th><\/tr><\/thead><tbody><tr><td><a href=\"https:\/\/www.restek.com\/c\/1751\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1751\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/a> <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1743\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/a><\/td><td>\u9178\u5316\u30a2\u30eb\u30df\u30cb\u30a6\u30e0<\/td><td>Alumina-Sulfate<\/td><td>AT-Alumina<\/td><td>GS-Alumina, CP-Al<sub>2<\/sub>O<sub>3<\/sub>\/NA<sub>2<\/sub>SO<sub>4<\/sub><\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1749\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/KCl*<\/a><\/td><td>\u9178\u5316\u30a2\u30eb\u30df\u30cb\u30a6\u30e0<\/td><td>Alumina-Chloride<\/td><td>\u2014<\/td><td>GS-Alumina KCl, HP PLOT Al<sub>2<\/sub>O<sub>3<\/sub>, CP-Al<sub>2<\/sub>O<sub>3<\/sub>\/KCl<\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/CFC*<\/a><\/td><td>\u9178\u5316\u30a2\u30eb\u30df\u30cb\u30a6\u30e0<\/td><td colspan=\"4\"><strong>unique product<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1750\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/MAPD<\/a> <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1743\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-Alumina BOND\/MAPD<\/a><\/td><td>\u9178\u5316\u30a2\u30eb\u30df\u30cb\u30a6\u30e0<\/td><td>\u2014<\/td><td>\u2014<\/td><td>Select Al<sub>2<\/sub>O<sub>3<\/sub> MAPD<\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1752\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Msieve 5A<\/a> <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1745\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-Msieve 5A<\/a><\/td><td>Molecular sieve 5A<\/td><td>Molsieve 5A<\/td><td>AT-Molesieve<\/td><td>HP PLOT Molesieve,<br>CP-Molesieve 5A<\/td><td>PLT-5A<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1753\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Q-BOND<\/a> <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1746\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-Q-BOND<\/a><\/td><td>100% \u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3<\/td><td>Supel-Q-PLOT<\/td><td>AT-Q<\/td><td>HP PLOT Q ,CP-PoraPlot Q, PoraBond Q<\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-QS-BOND*<\/a><\/td><td>\u4e2d\u6975\u6027\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc<\/td><td>\u2014<\/td><td>\u2014<\/td><td>GS-Q<\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1755\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-S-BOND*<\/a><\/td><td>DVB\u30d3\u30cb\u30eb\u30d4\u30ea\u30b8\u30f3\u30dd\u30ea\u30de\u30fc<\/td><td>\u2014<\/td><td>\u2014<\/td><td>CP-PoraPlot S<\/td><td>\u2014<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1756\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-U-BOND*<\/a><\/td><td>DVB\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u30b8\u30e1\u30bf\u30af\u30ea\u30ec\u30fc\u30c8\u30dd\u30ea\u30de\u30fc<\/td><td>\u2014<\/td><td>\u2014<\/td><td>HP PLOT U, CP-PoraPlot U, CP-PoraBond U<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u306e\u307f\u5bfe\u5fdc<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u3001\u5404\u88fd\u54c1\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3044\u3066\u3082\u3001Restek\u72ec\u81ea\u306e\u9769\u65b0\u7684\u6280\u8853\u304c\u4e00\u8cab\u3057\u3066\u6d3b\u304b\u3055\u308c\u3066\u304a\u308a\u3001\u5168\u3066\u306ePLOT\u30ab\u30e9\u30e0\u306b\u304a\u3044\u3066\u985e\u3092\u898b\u306a\u3044\u6027\u80fd\u3068\u518d\u73fe\u6027\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Alumina BOND \u30ab\u30e9\u30e0\u3000<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek Rt-Alumina BOND\u30ab\u30e9\u30e0\u306f\u3001C1\u301cC5\u306e\u70ad\u5316\u6c34\u7d20\u306b\u5bfe\u3057\u3066\u5353\u8d8a\u3057\u305f\u9078\u629e\u6027\u3092\u767a\u63ee\u3057\u3001\u98fd\u548c\u30fb\u4e0d\u98fd\u548c\u70ad\u5316\u6c34\u7d20\u306e\u3059\u3079\u3066\u306e\u7570\u6027\u4f53\u3092\u5ba4\u6e29\u4ee5\u4e0a\u3067\u9ad8\u7cbe\u5ea6\u306b\u5206\u96e2\u3057\u307e\u3059\u3002\u4ed6\u793e\u88fd\u54c1\u3068\u6bd4\u8f03\u3057\u3066\u3082\u3001\u305d\u306e\u5b89\u5b9a\u6027\u3068\u6027\u80fd\u306e\u9ad8\u3055\u306f\u7fa4\u3092\u629c\u3044\u3066\u304a\u308a\u3001\u591a\u304f\u306e\u5206\u6790\u73fe\u5834\u3067\u9ad8\u3044\u8a55\u4fa1\u3068\u4fe1\u983c\u3092\u7372\u5f97\u3057\u3066\u3044\u307e\u3059\u3002KCl\u3084Na\u2082SO\u2084\u306a\u3069\u306e\u7121\u6a5f\u5869\u3092\u7528\u3044\u305f\u72ec\u81ea\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u3001\u30a2\u30eb\u30df\u30ca\u56fa\u5b9a\u76f8\u306e\u53cd\u5fdc\u6027\u3092\u4f4e\u6e1b\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b8\u30a8\u30f3\u985e\u306a\u3069\u306e\u6975\u6027\u4e0d\u98fd\u548c\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u9ad8\u611f\u5ea6\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5f97\u3089\u308c\u3001\u76f4\u7dda\u6027\u306e\u3042\u308b\u5b9a\u91cf\u5206\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u5f37\u56fa\u306b\u7d50\u5408\u3055\u308c\u305f\u30a2\u30eb\u30df\u30ca\u56fa\u5b9a\u76f8\u306f\u7c92\u5b50\u306e\u5265\u96e2\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30d0\u30eb\u30d6\u5207\u66ff\u6642\u306e\u6ce8\u5165\u7cfb\u3084\u691c\u51fa\u7cfb\u3078\u306e\u6c5a\u67d3\u30ea\u30b9\u30af\u3092\u8457\u3057\u304f\u4f4e\u6e1b\u3057\u3066\u3044\u307e\u3059\u3002\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u9577\u671f\u904b\u7528\u3092\u652f\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001200\u00b0C\u307e\u3067\u306e\u9ad8\u6e29\u74b0\u5883\u3067\u3082\u5b89\u5b9a\u6027\u3092\u4fdd\u3061\u3001\u6c34\u5206\u306e\u5438\u7740\u306b\u3088\u308b\u6027\u80fd\u4f4e\u4e0b\u3082\u6700\u9ad8\u6e29\u5ea6\u3067\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306b\u3088\u3063\u3066\u5b8c\u5168\u306b\u56de\u5fa9\u53ef\u80fd\u3067\u3059\u3002\u9ad8\u3044\u30ab\u30e9\u30e0\u5bb9\u91cf\u3068\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u306b\u5bfe\u5fdc\u3057\u3001\u4e0d\u7d14\u7269\u5206\u6790\u306b\u304a\u3051\u308bppm\u30ec\u30d9\u30eb\u306e\u5fae\u91cf\u6210\u5206\u5206\u6790\u304b\u3089\u63ee\u767a\u6027\u70ad\u5316\u6c34\u7d20\u306e\u767e\u5206\u7387\u30ec\u30d9\u30eb\u306e\u5b9a\u91cf\u307e\u3067\u3001\u5e38\u306b\u512a\u308c\u305f\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3068\u518d\u73fe\u6027\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u88fd\u9020\u306b\u306f\u9ad8\u54c1\u8cea\u306a\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3057\u3066\u304a\u308a\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u91d1\u5c5e\u88fdMXT\u30c1\u30e5\u30fc\u30d6\u306e\u9078\u629e\u3082\u53ef\u80fd\u3002\u9577\u5e74\u306e\u5b9f\u7e3e\u306b\u88cf\u6253\u3061\u3055\u308c\u305fRestek Rt-Alumina BOND PLOT\u30ab\u30e9\u30e0\u306f\u3001\u53b3\u3057\u3044\u5206\u6790\u30cb\u30fc\u30ba\u306b\u3082\u5fdc\u3048\u308b\u7406\u60f3\u7684\u306a\u9078\u629e\u80a2\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3059\u3079\u3066\u306eRt-Alumina BOND\u30ab\u30e9\u30e0\u306f\u5fb9\u5e95\u7684\u306b\u30c6\u30b9\u30c8\u3055\u308c\u3066\u304a\u308a\u3001\u518d\u73fe\u6027\u306e\u3042\u308b\u4fdd\u6301\u6642\u9593\u3068\u4e88\u6e2c\u53ef\u80fd\u306a\u30d5\u30ed\u30fc\u6319\u52d5\u304c\u4fdd\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u70ad\u5316\u6c34\u7d20\u30c6\u30b9\u30c8\u30df\u30c3\u30af\u30b9\u3067\u78ba\u8a8d\u3059\u308b\u306e\u306f\u3001\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u4fdd\u6301\u3068\u9078\u629e\u6027\u3067\u3059\u3002\u56fa\u5b9a\u76f8\u4fdd\u6301\u306e\u6307\u6a19\u3067\u3042\u308b\u4fdd\u6301\u4fc2\u6570k\u306f1,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u3092\u4f7f\u7528\u3057\u3066\u7b97\u51fa\u3057\u307e\u3059\u3002\u4e00\u65b9\u3001\u9078\u629e\u6027\u306f\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u3068\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u306e\u4fdd\u6301\u6307\u6570\u3092\u7528\u3044\u3066\u8a55\u4fa1\u3055\u308c\u307e\u3059\u3002<em>trans<\/em>-2-\u30d6\u30c6\u30f3\u30681-\u30d6\u30c6\u30f3\u306e\u5206\u96e2\u3082\u691c\u8a3c\u3055\u308c\u3001\u52b9\u7387\u8a55\u4fa1\u306b\u306f1,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u3092\u4f7f\u7528\u3057\u3066\u30e1\u30fc\u30c8\u30eb\u5f53\u305f\u308a\u306e\u7406\u8ad6\u6bb5\u6570\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Alumina BOND\/Na\u2082SO\u2084\u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\uff09&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08Na\u2082SO\u2084\u306b\u3088\u308b\u4e0d\u6d3b\u6027\u5316\uff09<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30d6\u30bf\u30f3\u306e\u5f8c\u306b\u30a2\u30bb\u30c1\u30ec\u30f3\u3068\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u304c\u6eb6\u51fa<\/li>\n\n\n\n<li>\u30d6\u30c6\u30f3\u7570\u6027\u4f53\uff08\u30d6\u30c6\u30f3\u6d41\u4e2d\u306e\u4e0d\u7d14\u7269\uff09\u306e\u6700\u9069\u5206\u96e2<\/li>\n\n\n\n<li>1,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u306e\u5f8c\u306b\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u304c\u6eb6\u51fa<\/li>\n\n\n\n<li>\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u304b\u306a\u308a\u524d\u306b\u30b7\u30af\u30ed\u30d7\u30ed\u30d1\u30f3\uff08\u30d7\u30ed\u30d4\u30ec\u30f3\u4e2d\u306e\u4e0d\u7d14\u7269\uff09\u304c\u6eb6\u51fa<\/li>\n\n\n\n<li>200\u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n\n\n\n<li>\u91d1\u5c5e\u88fdMXT\u30c1\u30e5\u30fc\u30d6\u3082\u5229\u7528\u53ef\u80fd\uff01<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1751\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Alumina BOND (Na<sub>2<\/sub>SO<sub>4<\/sub>)\u30ab\u30e9\u30e0\u3067\u306e\u7cbe\u88fd\u30ac\u30b9\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01085.png\" alt=\"Refinery Gas on Rt-Alumina BOND (Na&lt;sub&gt;2&lt;\/sub&gt;SO&lt;sub&gt;4&lt;\/sub&gt;)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC01085<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19756<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PLOT-library<\/li><li>Refinery Gas<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01085.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Alumina BOND\/KCl\u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\uff09&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08KCl\u306b\u3088\u308b\u4e0d\u6d3b\u6027\u5316\uff09<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Restek\u306e\u6700\u3082\u4f4e\u6975\u6027\u306e\u30a2\u30eb\u30df\u30ca\u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>\u6c34\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306b\u304f\u304f\u3001\u518d\u751f\u306e\u983b\u5ea6\u3092\u524a\u6e1b<\/li>\n\n\n\n<li><em>n<\/em>-\u30d6\u30bf\u30f3\u306e\u524d\u306b\u30a2\u30bb\u30c1\u30ec\u30f3\u304c\u6eb6\u51fa<\/li>\n\n\n\n<li>1,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u306e\u524d\u306b\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\uff081,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u4e2d\u306e\u4e0d\u7d14\u7269\uff09\u304c\u6eb6\u51fa<\/li>\n\n\n\n<li>200\u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1749\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Alumina BOND\/KCl, Rtx-1\u30ab\u30e9\u30e0\u3067\u306eASTM D6159-97\u898f\u5236\u306b\u3088\u308b\u30a8\u30c1\u30ec\u30f3\u304a\u3088\u3073C1\uff5eC\uff15\u70ad\u5316\u6c34\u7d20\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01110.png\" alt=\"Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND\/KCl, Rtx-1\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC01110<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19760<\/li><li>19760<\/li><li>10179<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>ASTM D6159-97<\/li><li>Ethylene<\/li><li>PLOT-library<\/li><li>Rt-Alumina BOND\/KCL<\/li><li>astm-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01110.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Alumina BOND\/CFC\u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\uff09<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff08\u30d5\u30ed\u30f3\uff09\u5316\u5408\u7269\uff08CFC\uff09\u306b\u5bfe\u3059\u308b\u4e0d\u6d3b\u6027\u5ea6\u304c\u5411\u4e0a<\/li>\n\n\n\n<li>\u9078\u629e\u6027\u306e\u9ad8\u3044\u30a2\u30eb\u30df\u30ca\u30d9\u30fc\u30b9\u30ab\u30e9\u30e0\u3067\u3001\u307b\u3068\u3093\u3069\u306e\u30d5\u30ed\u30f3\u3092\u5206\u96e2<\/li>\n\n\n\n<li>CFC\u306b\u5bfe\u3059\u308b\u5f37\u3044\u4fdd\u6301\u529b\u3068\u9ad8\u3044\u8ca0\u8377\u5bb9\u91cf<\/li>\n\n\n\n<li>200\u2103\u307e\u3067\u5b89\u5b9a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Alumina BOND\/CFC\u5438\u7740\u5264\u306f\u3001\u63ee\u767a\u6027\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u3001\u7279\u306bCFC\uff08\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff09\u306e\u4fdd\u6301\u306b\u6700\u9069\u3067\u3059\u3002\u9078\u629e\u6027\u304c\u9ad8\u304f\u3001\u5e83\u7bc4\u56f2\u306eCFC\u7570\u6027\u4f53\u3092\u5e38\u6e29\u4ee5\u4e0a\u3067\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Rt-Alumina BOND\/CFC\u30ab\u30e9\u30e0\u306f\u3001\u30a2\u30eb\u30df\u30ca\u306e\u53cd\u5fdc\u6027\u3092\u4f4e\u6e1b\u3055\u305b\u308b\u305f\u3081\u306b\u5fb9\u5e95\u7684\u306b\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3044\u304f\u3064\u304b\u306e\u5358\u4e00\u307e\u305f\u306f\u4e8c\u91cd\u7f6e\u63dbCFC\u306b\u5bfe\u3057\u3066\u306f\u307e\u3060\u82e5\u5e72\u306e\u6b8b\u5b58\u53cd\u5fdc\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306e\u5927\u90e8\u5206\u306f\u30e1\u30a4\u30f3\u30b9\u30c8\u30ea\u30fc\u30e0\u306e\u30d7\u30ed\u30bb\u30b9\u3084\u4e0d\u7d14\u7269\u5206\u6790\u3067\u6b63\u78ba\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a>\u3000<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Alumina BOND\/CFC\u30ab\u30e9\u30e0\u3067\u306e1,1,1,2-\u30c6\u30c8\u30e9\u30d5\u30eb\u30aa\u30ed\u30a8\u30bf\u30f3 (CFC-134a)\u306e\u4e0d\u7d14\u7269\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1155.png\" alt=\"Impurity Analysis of 1,1,1,2-Tetrafluoroethane (CFC-134a) on Rt-Alumina BOND\/CFC\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1155<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19763<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>1,1,2,2-tetrafluoroethane<\/li><li>CFC<\/li><li>CFCs<\/li><li>PLOT-library<\/li><li>Rt-Alumina<\/li><li>VOA<\/li><li>bond<\/li><li>chlorofluorocarbons<\/li><li>volatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1155.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Alumina BOND\/MAPD \u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab PLOT\uff09<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6700\u9069\u5316\u3055\u308c\u305f\u4e0d\u6d3b\u6027\u5316\u306b\u3088\u308a\u3001\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u3092\u5fae\u91cf\u6fc3\u5ea6\u3067\u5206\u6790\u3059\u308b\u969b\u306b\u6700\u5927\u306e\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u7372\u5f97<\/li>\n\n\n\n<li>\u5b89\u5b9a\u3057\u305f\u30ec\u30b9\u30dd\u30f3\u30b9\u30d5\u30a1\u30af\u30bf\u30fc\u306b\u3088\u308a\u3001\u518d\u6821\u6b63\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u30d7\u30ed\u30bb\u30b9\u30bf\u30a4\u30d7\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u6700\u9069<\/li>\n\n\n\n<li>\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u306b\u3088\u308a\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u4f4e\u6e1b\u3057\u3001\u5206\u96e2\u3092\u6539\u5584<\/li>\n\n\n\n<li>250 \u00b0C\u307e\u3067\u306e\u6e29\u5ea6\u7bc4\u56f2\u62e1\u5f35\u306b\u3088\u308a\u3001\u9ad8\u5206\u5b50\u91cf\uff08HMW\uff09\u70ad\u5316\u6c34\u7d20\u306e\u8fc5\u901f\u306a\u6eb6\u51fa\u3068\u6c34\u3078\u306e\u66dd\u9732\u5f8c\u306e\u30ab\u30e9\u30e0\u518d\u751f\u52a0\u901f\u3092\u5b9f\u73fe<\/li>\n\n\n\n<li>250 \u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n\n\n\n<li>\u91d1\u5c5e\u88fdMXT\u30c1\u30e5\u30fc\u30d6\u3082\u5229\u7528\u53ef\u80fd\uff01<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Restek \u306e\u7814\u7a76\u958b\u767a\u5316\u5b66\u8005\u306f\u3001Rt-Alumina BOND\/MAPD \u30ab\u30e9\u30e0\u306b\u9069\u7528\u3055\u308c\u308b\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3092\u6700\u9069\u5316\u3057\u3001C1\uff5eC5 \u70ad\u5316\u6c34\u7d20\u6fc3\u5ea6\u304c\u9ad8\u3044\u70ad\u5316\u6c34\u7d20\u30b9\u30c8\u30ea\u30fc\u30e0\u4e2d\u306e\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u306a\u3069\u306e\u6975\u6027\u70ad\u5316\u6c34\u7d20\u306e\u5fae\u91cf\u30ec\u30d9\u30eb\u306e\u5206\u6790\u3092\u6539\u5584\u3057\u307e\u3057\u305f\u3002Restek\u306eAlumina PLOT\u4e0d\u6d3b\u6027\u5316\u306b\u3088\u308a\u3001\u512a\u308c\u305f\u518d\u73fe\u6027\u3068\u5b89\u5b9a\u3057\u305f\u30ec\u30b9\u30dd\u30f3\u30b9\u30d5\u30a1\u30af\u30bf\u30fc\u3092\u5099\u3048\u305f\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044\u30ab\u30e9\u30e0\u304c\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u518d\u6821\u6b63\u304c\u5fc5\u8981\u3068\u306a\u308b\u307e\u3067\u306e\u5206\u6790\u56de\u6570\u3092\u6700\u5927\u5316\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u304c\u9ad8\u3044\u305f\u3081\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u6e1b\u5c11\u3057\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306e\u5206\u96e2\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u304c250\u2103\u3067\u3042\u308b\u305f\u3081\u3001\u30c9\u30c7\u30ab\u30f3\u307e\u3067\u306e\u70ad\u5316\u6c34\u7d20\u3092\u3088\u308a\u8fc5\u901f\u306b\u6eb6\u51fa\u3055\u305b\u3001\u30b5\u30f3\u30d7\u30eb\u3084\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304b\u3089\u306e\u6c34\u306b\u66dd\u9732\u3055\u308c\u305f\u5f8c\u3001\u30ab\u30e9\u30e0\u306e\u518d\u751f\u306b\u304b\u304b\u308b\u6642\u9593\u3092\u77ed\u7e2e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1750\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Alumina BOND\/MAPD\u30ab\u30e9\u30e0\u3067\u306e1,3-\u30d6\u30bf\u30b8\u30a8\u30f3\u306e\u5206\u6790\u7d50\u679c\uff08\u4e0d\u7d14\u7269\u5206\u6790\uff09\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc1211.png\" alt=\"1,3-Butadiene on Rt-Alumina BOND\/MAPD (Purity Analysis)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC1211<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19778<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>1,3-butadiene<\/li><li>PLOT-library<\/li><li>crude<\/li><li>purity<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc1211.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A PLOT\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek \u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d65A PLOT\u30ab\u30e9\u30e0\u306f\u3001\u30a2\u30eb\u30b4\u30f3\/\u9178\u7d20\u304a\u3088\u3073\u4e00\u9178\u5316\u70ad\u7d20\u3092\u542b\u3080\u305d\u306e\u4ed6\u306e\u6c38\u4e45\u30ac\u30b9\u3092\u52b9\u7387\u7684\u306b\u5206\u96e2\u3059\u308b\u305f\u3081\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u5225\u306a\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3068\u4e0d\u6d3b\u6027\u5316\u624b\u9806\u306b\u3088\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u52b9\u7387\u3068\u591a\u5b54\u8cea\u5c64\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u5b8c\u5168\u6027\u304c\u4fdd\u8a3c\u3055\u308c\u307e\u3059\u3002\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u306f\u975e\u5e38\u306b\u9ad8\u3044\u4fdd\u6301\u3092\u767a\u63ee\u3057\u3001\u5e38\u6e29\u4ee5\u4e0a\u306e\u6e29\u5ea6\u3067\u6c38\u4e45\u30ac\u30b9\u306e\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001Restek\u306e\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u306b\u3088\u308a\u3001\u4e00\u9178\u5316\u70ad\u7d20\u3092\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u3068\u3057\u3066\u6eb6\u51fa\u3055\u305b\u308b\u3053\u3068\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001Restek\u72ec\u81ea\u306e\u56fa\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u306b\u3088\u308a\u3001\u30d0\u30eb\u30d6\u306e\u958b\u9589\u304c\u983b\u7e41\u306b\u884c\u308f\u308c\u305f\u5f8c\u3067\u3082\u5747\u4e00\u306a\u7c92\u5b50\u304c\u30c1\u30e5\u30fc\u30d6\u306b\u4ed8\u7740\u3057\u305f\u307e\u307e\u3067\u3042\u308b\u3053\u3068\u304c\u4fdd\u8a3c\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Msieve 5A\u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\uff09<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30a2\u30eb\u30b4\u30f3\u3001\u9178\u7d20\u3001\u4e00\u9178\u5316\u70ad\u7d20\u306e\u30b7\u30e3\u30fc\u30d7\u3067\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u306b\u3088\u308a\u7cbe\u5ea6\u304c\u5411\u4e0a<\/li>\n\n\n\n<li>\u5e38\u6e29\u4ee5\u4e0a\u3067\u6c38\u4e45\u30ac\u30b9\u306e\u5206\u96e2\u304c\u5bb9\u6613<\/li>\n\n\n\n<li>Restek PLOT\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306f\u7c92\u5b50\u306e\u8131\u843d\u3092\u4f4e\u6e1b\u3057\u3001\u30d5\u30ed\u30fc\u306e\u518d\u73fe\u6027\u3092\u5411\u4e0a\u3055\u305b\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u305f\u3081\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u77ed\u7e2e<\/li>\n\n\n\n<li>300 \u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n\n\n\n<li>\u91d1\u5c5e\u88fdMXT\u30c1\u30e5\u30fc\u30d6\u3082\u5229\u7528\u53ef\u80fd\uff01<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1752\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Msieve 5A\u30ab\u30e9\u30e0\u3067\u306e\u30a2\u30eb\u30b4\u30f3\uff0f\u9178\u7d20\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u6c38\u4e45\u30ac\u30b9\u306e\u5206\u96e2\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc00898.png\" alt=\"Permanent Gases Rt-Msieve 5A\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC00898<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19723<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PLOT-library<\/li><li>argon<\/li><li>permanent gases<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc00898.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u306f\u3001\u975e\u5e38\u306b\u512a\u308c\u305f\u4fdd\u6301\u3092\u793a\u3059\u30e6\u30cb\u30fc\u30af\u306a\u56fa\u5b9a\u76f8\u3067\u3059\u3002\u6975\u6027\u304a\u3088\u3073\u975e\u6975\u6027\u5316\u5408\u7269\u306e\u4e21\u65b9\u3092\u6eb6\u51fa\u53ef\u80fd\u306a\u305f\u3081\u3001\u5e45\u5e83\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u5fdc\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u758e\u6c34\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u4fdd\u6301\u6642\u9593\u306b\u5bfe\u3057\u3066\u6c34\u5206\u306f\u5f71\u97ff\u3092\u4e0e\u3048\u305a\u3001\u3080\u3057\u308d\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u30d4\u30fc\u30af\u3068\u3057\u3066\u826f\u597d\u306b\u6eb6\u51fa\u3055\u308c\u307e\u3059\u3002Q-BOND\u306f\u3001\u6700\u3082\u975e\u6975\u6027\u3067\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u3067\u3042\u308a\u3001\u6a5f\u80fd\u57fa\u3092\u6dfb\u52a0\u3057\u3066\u6975\u6027\u3092\u9ad8\u3081\u305f\u30ab\u30e9\u30e0\u3082\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\uff08\u4f8b\uff1aQS-\u3001S-\u3001\u304a\u3088\u3073U-BOND\uff09\u3002\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fcPLOT\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u88fd\u9020\u5de5\u7a0b\u3067\u7c92\u5b50\u3092\u30c1\u30e5\u30fc\u30d6\u5185\u58c1\u306b\u5f37\u304f\u4ed8\u7740\u3055\u305b\u3066\u3044\u308b\u306e\u3067\u3001\u7c92\u5b50\u304c\u307b\u3068\u3093\u3069\u751f\u6210\u3055\u308c\u307e\u305b\u3093\u3002\u3053\u308c\u304c\u9078\u629e\u6027\u3068\u30d5\u30ed\u30fc\u306e\u518d\u73fe\u6027\u304c\u4fdd\u8a3c\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3067\u3042\u308b\u7406\u7531\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-Q-BOND\u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">100%\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3100%\u306e\u975e\u6975\u6027PLOT\u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>C1\uff5eC3\u70ad\u5316\u6c34\u7d20\u3084\u7570\u6027\u4f53\u304a\u3088\u3073C10\u307e\u3067\u306e\u30a2\u30eb\u30ab\u30f3\u306e\u5206\u6790\u306b\u6700\u9069<\/li>\n\n\n\n<li>CO<sub>2<\/sub>\u4fdd\u6301\u7387\u304c\u9ad8\u304f\u3001\u30ac\u30b9\u5206\u6790\u3092\u7c21\u7d20\u5316\uff08CO<sub>2<\/sub>\u3068\u30e1\u30bf\u30f3\u3092O<sub>2<\/sub>\/N<sub>2<\/sub>\/CO\u304b\u3089\u5e38\u6e29\u3067\u5206\u96e2\u53ef\u80fd\uff09<br>\uff08\u6ce8\uff1aO<sub>2<\/sub>\/N<sub>2<\/sub>\/CO\u306f\u5e38\u6e29\u3067\u5206\u96e2\u3057\u306a\u3044\uff09<\/li>\n\n\n\n<li>\u542b\u9178\u7d20\u5316\u5408\u7269\u3084\u6eb6\u5264\u306e\u5206\u6790\u306b\u5bfe\u5fdc<\/li>\n\n\n\n<li>\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6300 \u00b0C<\/li>\n\n\n\n<li>\u91d1\u5c5e\u88fdMXT\u30c1\u30e5\u30fc\u30d6\u3082\u5229\u7528\u53ef\u80fd\uff01<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1753\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-Q-BOND\u30ab\u30e9\u30e0\u3067\u306e\u6eb6\u5a92\u6df7\u5408\u7269\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01082.png\" alt=\"Solvent Mixture on Rt-Q-BOND\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC01082<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19742<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PLOT-library<\/li><li>solvents<\/li><li>xylene<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01082.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-QS-BOND \u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab PLOT\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u5b54\u6027\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30db\u30e2\u30dd\u30ea\u30de\u30fc<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5c11\u91cf\u306e4-\u30d3\u30cb\u30eb\u30d4\u30ea\u30b8\u30f3\u3092\u542b\u6709\u3057\u305f\u4e2d\u9593\u6975\u6027\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc PLOT \u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>\u30a8\u30bf\u30f3\u3001\u30a8\u30c1\u30ec\u30f3\u3001\u30a2\u30bb\u30c1\u30ec\u30f3\u3092\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u307e\u3067\u5206\u96e2<\/li>\n\n\n\n<li>250 \u00b0C \u307e\u3067\u5b89\u5b9a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-QS-BOND\u30ab\u30e9\u30e0\u3067\u306e\u7cbe\u88fd\u30ac\u30b9\u6df7\u5408\u7269\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01143.png\" alt=\"Refinery Gas on Rt-QS-BOND\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC01143<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19738<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Refniery Gas<\/li><li>Rt-QSBOND<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01143.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-S-BOND \u30ab\u30e9\u30e0\uff08\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab PLOT\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u5b54\u6027\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30db\u30e2\u30dd\u30ea\u30de\u30fc<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u542b\u91cf\u306e4-\u30d3\u30cb\u30eb\u30d4\u30ea\u30b8\u30f3\u3092\u542b\u6709\u3057\u305f\u4e2d\u6975\u6027\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fcPLOT\u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>\u975e\u6975\u6027\u304a\u3088\u3073\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u5bfe\u5fdc<\/li>\n\n\n\n<li>250\u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1755\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-S-BOND\u30ab\u30e9\u30e0\u3067\u306e\u6eb6\u5a92\u6df7\u5408\u7269\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01080.png\" alt=\"Solvent Mixture on Rt-S-BOND\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_PC01080<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19746<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PLOT-library<\/li><li>xylene<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_pc01080.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-U-BOND\u30ab\u30e9\u30e0(\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30fb\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff0f\u30b8\u30e1\u30c1\u30eb\u30a2\u30af\u30ea\u30ec\u30fc\u30c8<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Restek\u306e\u6700\u3082\u6975\u6027\u306e\u9ad8\u3044\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30fb\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff0f\u30b8\u30e1\u30c1\u30eb\u30a2\u30af\u30ea\u30ec\u30fc\u30c8\u3092\u7d44\u307f\u8fbc\u3093\u3060\u6975\u6027PLOT\u30ab\u30e9\u30e0<\/li>\n\n\n\n<li>\u6975\u6027\u304a\u3088\u3073\u975e\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u5bfe\u3057\u4e0d\u6d3b\u6027\u5ea6\u304c\u9ad8\u3044<\/li>\n\n\n\n<li>\u4e00\u822c\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3 \uff08\u70ad\u5316\u6c34\u7d20\u30b9\u30c8\u30ea\u30fc\u30e0\u4e2d\u306eH2S\u3001COS\u3001\u30e1\u30eb\u30ab\u30d7\u30bf\u30f3\u3092\u542b\u3080\uff09\u306b\u5bfe\u5fdc<\/li>\n\n\n\n<li>190 \u00b0C\u307e\u3067\u5b89\u5b9a<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1756\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Rt-U-BOND\u30ab\u30e9\u30e0\u3067\u306e\u30db\u30eb\u30e0\u30a2\u30eb\u30c7\u30d2\u30c9\u306e\u5206\u6790\u7d50\u679c\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\">\u9ad8\u6975\u6027\u5206\u6790\u7269\u306b\u5bfe\u3059\u308b\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch01137.png\" alt=\"Formaldehyde on Rt-U-BOND\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CH01137<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19750<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Formaldehyde<\/li><li>PLOT-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ch01137.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u91d1\u5c5e\u88fdMXT PLOT\u30ab\u30e9\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u91d1\u5c5e\u88fdMXT PLOT\u30ab\u30e9\u30e0\u306e\u5229\u70b9\u306f\u4ee5\u4e0b\u306e\u901a\u308a\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30b3\u30a4\u30eb\u5f84\u304c\u5c0f\u3055\u304f\u3001\u72ed\u3044\u30b9\u30da\u30fc\u30b9\u306b\u6700\u9069<\/li>\n\n\n\n<li>\u53d6\u308a\u6271\u3044\u3084\u3059\u304f\u885d\u6483\u306b\u8010\u3048\u308b\u4e08\u592b\u306a\u6750\u8cea<\/li>\n\n\n\n<li>\u30d7\u30ed\u30bb\u30b9GC\u3084\u30d5\u30a3\u30fc\u30eb\u30c9\u88c5\u7f6e\u3067\u5805\u7262\u306a\u6027\u80fd\u3092\u767a\u63ee\u3059\u308b\u3088\u3046\u306a\u8a2d\u8a08<\/li>\n\n\n\n<li>\u30b3\u30a4\u30eb\u76f4\u5f843.5\u30a4\u30f3\u30c1\u307e\u305f\u306f\u76f4\u5f847\u30a4\u30f3\u30c1\u300111\u30d4\u30f3\u30b1\u30fc\u30b8\u3067\u63d0\u4f9b<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306e\u5316\u5b66\u8005\u306f\u3001\u4eba\u6c17\u306e\u3042\u308bPLOT\u30ab\u30e9\u30e0\u306e\u591a\u304f\u3092Siltek\u51e6\u7406\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u3067\u88fd\u9020\u3059\u308b\u6280\u8853\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u91d1\u5c5e\u88fdMXT PLOT\u30ab\u30e9\u30e0\u306f\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30abPLOT\u30ab\u30e9\u30e0\u3068\u540c\u3058\u7279\u6027\u3068\u6027\u80fd\u3092\u6301\u3061\u306a\u304c\u3089\u3001\u307b\u307c\u58ca\u308c\u305a\u3001\u975e\u5e38\u306b\u5c0f\u3055\u306a\u76f4\u5f84\u306b\u5dfb\u304f\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u30d7\u30ed\u30bb\u30b9GC\u3084\u30d5\u30a3\u30fc\u30eb\u30c9\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u305d\u306e\u5b9f\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>MXT-Msieve 5A<\/strong><br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1745\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>MXT-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/strong><br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1743\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>MXT-Alumina BOND\/MAPD<\/strong><br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1742\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>MXT-Q-BOND<\/strong><br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1746\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">MXT\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30b3\u30cd\u30af\u30bf\u30ad\u30c3\u30c8\uff08\u91d1\u5c5e\u88fd\u30ab\u30e9\u30e0\u7528\uff09<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\uff0f\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u3092MXT\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u30ab\u30e9\u30e0\u306b\u63a5\u7d9a<\/li>\n\n\n\n<li>\u4f4e\u71b1\u5bb9\u91cf\u306b\u3088\u308a\u3001\u6025\u901f\u306a\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u5206\u6790\u306b\u5bfe\u5fdc<\/li>\n\n\n\n<li>\u30b9\u30c6\u30f3\u30ec\u30b9\u30b9\u30c1\u30fc\u30eb\u88fd\u30d5\u30a7\u30e9\u30eb\u3068\u30ca\u30c3\u30c8\u3092\u63a1\u7528<\/li>\n\n\n\n<li>Y\u5b57\u578b\u304a\u3088\u3073\u30e6\u30cb\u30aa\u30f3\u578b\u3067\u5229\u7528\u53ef\u80fd<\/li>\n\n\n\n<li>Siltek\u51e6\u7406\u306b\u3088\u308a\u3001\u7a76\u6975\u306e\u4e0d\u6d3b\u6027\u3092\u5b9f\u73fe<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5404\u30ad\u30c3\u30c8\u306b\u306fMXT\u30e6\u30cb\u30aa\u30f3\u30011\/32\u30a4\u30f3\u30c1\u306e\u30d5\u30a7\u30e9\u30eb2\u500b\u3001\u30ca\u30c3\u30c8\u3092\u542b\u6709<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3000<a href=\"https:\/\/www.restek.com\/global\/ja\/search\/mxt\/_\/N-3486980084?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30b3\u30cd\u30af\u30bf\u30ad\u30c3\u30c8\u3092\u4eca\u3059\u3050\u30aa\u30fc\u30c0\u30fc\uff01<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u3000<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/PCSS1163.pdf\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/PCSS1163.pdf\" rel=\"noreferrer noopener\">PLOT\u30ab\u30e9\u30e0\u306ePDF\uff08\u82f1\u8a9e\u306e\u307f\uff09\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089\u304b\u3089<\/a><\/h2>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306ePLOT\u30ab\u30e9\u30e0\u306f\u3001\u9769\u65b0\u7684\u306a\u7d50\u5408\u6280\u8853\u3067\u7c92\u5b50\u5265\u96e2\u3092\u5927\u5e45\u306b\u6291\u5236\u3057\u3001\u5b89\u5b9a\u3057\u305f\u4fdd\u6301\u6642\u9593\u3068\u9ad8\u3044\u518d\u73fe\u6027\u3092\u5b9f\u73fe\u3002\u6c38\u4e45\u30ac\u30b9\u3084\u63ee\u767a\u6027\u5316\u5408\u7269\u3001\u4e0d\u7d14\u7269\u5206\u6790\u306b\u6700\u9069\u306a\u9ad8\u52b9\u7387\u30fb\u9ad8\u8010\u4e45\u30ab\u30e9\u30e0\u3067\u3001\u691c\u51fa\u5668\u3084\u30d0\u30eb\u30d6\u306e\u6c5a\u67d3\u30ea\u30b9\u30af\u3082\u4f4e\u6e1b\u3002\u591a\u69d8\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u5fdc\u3057\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7590,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-43889","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-PCSS1163-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43889","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=43889"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43889\/revisions"}],"predecessor-version":[{"id":79572,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/43889\/revisions\/79572"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7590"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=43889"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=43889"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=43889"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=43889"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=43889"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=43889"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=43889"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=43889"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=43889"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}