{"id":44569,"date":"2025-07-14T18:14:20","date_gmt":"2025-07-14T18:14:20","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44569"},"modified":"2026-08-04T00:29:23","modified_gmt":"2026-08-04T00:29:23","slug":"which-pieces-of-documentation-are-available-with-my-certificate-of-analysis-cofa-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot4935-ja\/which-pieces-of-documentation-are-available-with-my-certificate-of-analysis-cofa-jp","title":{"rendered":"\u5206\u6790\u8a3c\u660e\u66f8\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u66f8\u985e\u304c\u6dfb\u4ed8\u3055\u308c\u307e\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"has-medium-font-size wp-block-paragraph\">Restek\u306f\u3001<strong>Gravimetric\uff08\u91cd\u91cf\u8a18\u9332<\/strong>\uff09\u3001<strong>Chromatographic\uff08\u7d44\u6210\u78ba\u8a8d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4ed8\u304d\uff09<\/strong>\u3001<strong>Chromatographic Plus\uff08n=3\u30fb\u30ed\u30c3\u30c8\u9593\u7d71\u8a08\u6bd4\u8f03\u304c\u8ffd\u52a0\uff09<\/strong>\u306e3\u7a2e\u985e\u306e\u5206\u6790\u8a3c\u660e\u66f8\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306b\u7570\u306a\u308b\u5185\u5bb9\u306e\u6587\u66f8\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u305d\u306e\u6982\u8981\u306f\u4ee5\u4e0b\u306e\u56f3\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"393\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a-1024x393.jpg\" alt=\"Outline of which pieces of documentation are included with Certificate of Analysis.\" class=\"wp-image-35925\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a-1024x393.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a-300x115.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a-768x295.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a-1536x590.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNOT3397B-01a.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Reference Standard\u30ab\u30bf\u30ed\u30b0\u54c1\u306b\u3064\u3044\u3066\u306f\u3001\u307b\u307c\u3059\u3079\u3066\u306b\u95a2\u3057\u3066<strong>\u5206\u6790\u8a3c\u660e\u66f8-\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fcPlus<\/strong>\u304c\u6dfb\u4ed8\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u307b\u3068\u3093\u3069\u306e\u30ab\u30b9\u30bf\u30e0\u54c1\u306eReference Standard\u306f\u30013\u7a2e\u985e\u306e\u5206\u6790\u8a3c\u660e\u66f8\u304b\u3089\u9078\u629e\u3044\u305f\u3060\u3051\u307e\u3059\u3002Restek\u306eISO\u8a8d\u5b9a\u7bc4\u56f2\u306b\u542b\u307e\u308c\u308bReference Standard\u306f\u3001\u5206\u6790\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u308b\u5185\u5bb9\u306b\u95a2\u4fc2\u306a\u304f\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li><strong><mark style=\"background-color:var(--global-palette7)\" class=\"has-inline-color\">\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Gravimetric\uff08\u91cd\u91cf\u8a18\u9332\uff09<\/mark><\/strong>\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea (CRM) \u306b\u3064\u3044\u3066\u306f\u3001\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong><mark style=\"background-color:var(--global-palette7)\" class=\"has-inline-color\">\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Chromatographic\uff08\u7d44\u6210\u78ba\u8a8d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4ed8\u304d\uff09<\/mark><\/strong>\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001CRM\u306b\u3064\u3044\u3066\u306f\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002\u202f\u3055\u3089\u306b\u3001\u30d1\u30c3\u30b1\u30fc\u30b8\u30e6\u30cb\u30c3\u30c8\u304b\u30891\u3064\u3092\u629c\u304d\u53d6\u308a\u3001\u6df7\u5408\u7269\u306e\u7d44\u6210\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u9069\u5207\u306a\u624b\u6cd5\u3067\u30c6\u30b9\u30c8\u3057\u307e\u3059\u3002\u202f\u5404\u30d4\u30fc\u30af\u304c\u540c\u5b9a\u3055\u308c\u305f\u3053\u306e\u6a19\u6e96\u7269\u8cea\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li><mark style=\"background-color:var(--global-palette7)\" class=\"has-inline-color\"><strong>\u5206\u6790\u8a3c\u660e\u66f8 \u2013 Chromatographic Plus\uff08n=3\u30fb\u30ed\u30c3\u30c8\u9593\u7d71\u8a08\u6bd4\u8f03\u304c\u8ffd\u52a0\uff09<\/strong>\u00a0<\/mark>\u306b\u306f\u3001\u3059\u3079\u3066\u306e\u539f\u6750\u6599\u60c5\u5831\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3068\u7d14\u5ea6\u3001\u7570\u6027\u4f53\u5316\u5408\u7269\u306e\u7570\u6027\u4f53\u6bd4\u3001\u304a\u3088\u3073\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002CRM\u306b\u3064\u3044\u3066\u306f\u95a2\u9023\u3059\u308b\u4e0d\u78ba\u304b\u3055\u3082\u8a18\u8f09\u3055\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d1\u30c3\u30b1\u30fc\u30b8\u30e6\u30cb\u30c3\u30c8\u306e\u3046\u30611\u3064\u306fn=3\u3067\u5206\u6790\u3055\u308c\u3001\u305d\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u5024\u306f\u7d71\u8a08\u7684\u306b\u5225\u30ed\u30c3\u30c8\u3068\u6bd4\u8f03\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5225\u30ed\u30c3\u30c8\u306f\u3001\u305d\u306e\u524d\u306e\u30ed\u30c3\u30c8\u304c\u3042\u308b\u5834\u5408\u306f\u524d\u306e\u30ed\u30c3\u30c8\u3001\u307e\u305f\u306f\u65b0\u3057\u304f\u751f\u7523\u3055\u308c\u305f\u72ec\u7acb\u3057\u305f2\u756a\u76ee\u306e\u30ed\u30c3\u30c8\u3068\u306a\u308a\u307e\u3059\u3002\u202f\u5404\u30d4\u30fc\u30af\u304c\u540c\u5b9a\u3055\u308c\u305f\u3053\u306e\u6a19\u6e96\u7269\u8cea\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u3055Restek\u306e\u3059\u3079\u3066\u306e\u30ab\u30bf\u30ed\u30b0\u54c1\u304a\u3088\u3073\u30ab\u30b9\u30bf\u30e0\u54c1\u306e\u6a19\u6e96\u7269\u8cea\u306b\u95a2\u3059\u308b\u3001\u88fd\u54c1\u8a3c\u660e\u66f8\u3001\u5b9a\u91cf\u30a2\u30c3\u30bb\u30a4\u30c7\u30fc\u30bf\u3068\u7d71\u8a08\u5024\u3001\u6a19\u6e96\u7269\u8cea\u30d0\u30c3\u30c1\u30ec\u30b3\u30fc\u30c9\u3092\u542b\u3080\u8a73\u7d30\u306a\u30c7\u30fc\u30bf\u30d1\u30c3\u30af\u306f\u3001\u30ed\u30c3\u30c8\u756a\u53f7\u3092\u5165\u529b\u3057\u3066<a href=\"https:\/\/www.restek.com\/global\/ja\/documentation-search\" target=\"_blank\" rel=\"noreferrer noopener\">\u300cSDS\u3001COA\u3001\u30c7\u30fc\u30bf\u30d1\u30c3\u30af\u306e\u691c\u7d22\u300d<\/a>\u304b\u3089\u5165\u624b\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u8a73\u7d30\u60c5\u5831\u306f<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnbr1845-ja\/restek-reference-standards\" target=\"_blank\" rel=\"noreferrer noopener\">\u300c\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3068\u306f\uff5cISO17034\u306e\u57fa\u790e\u77e5\u8b58\u300d<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u306f\u3001Gravimetric\uff08\u91cd\u91cf\u8a18\u9332\uff09\u3001Chromatographic\uff08\u7d44\u6210\u78ba\u8a8d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4ed8\u304d\uff09\u3001Chromatographic Plus\uff08n=3\u30fb\u30ed\u30c3\u30c8\u9593\u7d71\u8a08\u6bd4\u8f03\u304c\u8ffd\u52a0\uff09\u306e3\u7a2e\u985e\u306e\u5206\u6790\u8a3c\u660e\u66f8\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306b\u7570\u306a\u308b\u5185\u5bb9\u306e\u6587\u66f8\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u305d\u306e\u6982\u8981\u306f\u4ee5\u4e0b\u306e\u56f3\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002 Reference Standard\u30ab\u30bf\u30ed\u30b0\u54c1\u306b\u3064\u3044\u3066\u306f\u3001\u307b\u307c\u3059\u3079\u3066\u306b\u95a2\u3057\u3066\u5206\u6790\u8a3c\u660e\u66f8-\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fcPlus\u304c\u6dfb\u4ed8\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u307b\u3068\u3093\u3069\u306e\u30ab\u30b9\u30bf\u30e0\u54c1\u306eReference Standard\u306f\u30013\u7a2e\u985e\u306e\u5206\u6790\u8a3c\u660e\u66f8\u304b\u3089\u9078\u629e\u3044\u305f\u3060\u3051\u307e\u3059\u3002Restek\u306eISO\u8a8d\u5b9a\u7bc4\u56f2\u306b\u542b\u307e\u308c\u308bReference Standard\u306f\u3001\u5206\u6790\u8a3c\u660e\u66f8\u306b\u542b\u307e\u308c\u308b\u5185\u5bb9\u306b\u95a2\u4fc2\u306a\u304f\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002 \u8a73\u7d30\u60c5\u5831\u306f\u300c\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u3068\u306f\uff5cISO17034\u306e\u57fa\u790e\u77e5\u8b58\u300d\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u00a0<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2687,2721],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2579,2554],"resource-technique":[],"ppma_author":[2814,414],"class_list":["post-44569","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-reference-standards","tag-frequently-asked-questions-reference-standards-japan","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2687,"label":"FAQ: Reference Standards"},{"value":2721,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard"}],"product-library":[{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2687,"name":"FAQ: Reference Standards","slug":"faq-reference-standards","term_group":0,"term_taxonomy_id":2687,"taxonomy":"post_tag","description":"Browse frequently asked questions for reference standards.","parent":0,"count":58,"filter":"raw"},{"term_id":2721,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard","slug":"frequently-asked-questions-reference-standards-japan","term_group":0,"term_taxonomy_id":2721,"taxonomy":"post_tag","description":"","parent":0,"count":58,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44569"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44569\/revisions"}],"predecessor-version":[{"id":100155,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44569\/revisions\/100155"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44569"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44569"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44569"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44569"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44569"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44569"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44569"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44569"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}