{"id":44745,"date":"2025-09-04T18:03:12","date_gmt":"2025-09-04T18:03:12","guid":{"rendered":"https:\/\/discover.restek.com\/?p=44745"},"modified":"2026-04-07T01:16:29","modified_gmt":"2026-04-07T01:16:29","slug":"restek-capillary-column-installation-guide-section-iii-operational-information-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/instruction-sheets-ja\/gnot5429-ja\/restek-capillary-column-installation-guide-section-iii-operational-information-japan","title":{"rendered":"Restek \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u5b8c\u5168\u30ac\u30a4\u30c9 &#8211; \u30bb\u30af\u30b7\u30e7\u30f3 III: \u8a2d\u7f6e\u30fb\u64cd\u4f5c\u30fb\u4fdd\u7ba1\u30fb\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9"},"content":{"rendered":"\n<ol style=\"list-style-type:upper-alpha\" class=\"wp-block-list\">\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#standby-operation\">\u30b9\u30bf\u30f3\u30d0\u30a4\u64cd\u4f5c<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#column-removal-and-storage\">\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u5916\u3057\u3068\u4fdd\u7ba1<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#protection-against-dirty-samples\">\u6c5a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3059\u308b\u4fdd\u8b77<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#connecting-fused-silica-tubing\">\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u306e\u63a5\u7d9a<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#connecting-stainless-steel-tubing\">\u30b9\u30c6\u30f3\u30ec\u30b9\u30c1\u30e5\u30fc\u30d6\u306e\u63a5\u7d9a<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#column-maintenance\">\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9<\/a><\/li>\n\n\n\n<li><a href=\"articles\/restek-capillary-column-installation-guide-section-iii-operational-information-japan#injecting-water-and-other-solvents\">\u6c34\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u6eb6\u5a92\u306e\u6ce8\u5165<\/a><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>A. \u30b9\u30bf\u30f3\u30d0\u30a4\u64cd\u4f5c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u3092\u6570\u65e5\u9593\u4f7f\u7528\u3057\u306a\u3044\u304c\u3001\u88c5\u7f6e\u3092\u30b9\u30bf\u30f3\u30d0\u30a4\u72b6\u614b\u306b\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u306e\u6d41\u91cf\u309210 cc\/min\u306b\u6e1b\u3089\u3057\uff08\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u7bc0\u7d04\u3059\u308b\u305f\u3081\uff09\u3001\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092100 \u2103\uff5e150 \u2103\u306b\u7dad\u6301\u3057\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092\u3084\u3084\u9ad8\u6e29\u306b\u4fdd\u3064\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3078\u306e\u30bb\u30d7\u30bf\u30e0\u30d6\u30ea\u30fc\u30c9\u306e\u84c4\u7a4d\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30ab\u30e9\u30e0\u4f7f\u7528\u6642\u306e\u904e\u5270\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u5fc5\u8981\u6027\u3092\u4f4e\u6e1b\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u30b9\u30bf\u30f3\u30d0\u30a4\u72b6\u614b\u306b\u3059\u308b\u3068\u304d\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304c\u5341\u5206\u306b\u4f9b\u7d66\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u30923\u65e5\u4ee5\u4e0a\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u3059\u3079\u3066\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3057\u3001GC\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u305f\u307e\u307e\u306b\u3059\u308b\u5834\u5408\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u6b62\u3081\u305a\u3001\u5fc5\u305a\u5c11\u91cf\u306e\u30ac\u30b9\u3092\u6d41\u3057\u305f\u72b6\u614b\u3092\u4fdd\u3064\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ac\u30b9\u3082\u6b62\u3081\u308b\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u3082\u30b7\u30b9\u30c6\u30e0\u304b\u3089\u53d6\u308a\u5916\u3059\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>B. \u30ab\u30e9\u30e0\u306e\u53d6\u308a\u5916\u3057\u3068\u4fdd\u7ba1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u304b\u3089\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u5916\u3057\u307e\u3059\u3002\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3084\u691c\u51fa\u5668\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u30d5\u30a7\u30e9\u30eb\u304c\u6b8b\u3063\u3066\u3044\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u30d5\u30a7\u30e9\u30eb\u304c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u6b8b\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001Tapered Needle File \uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20106\" target=\"_blank\" rel=\"noopener\">20106<\/a>\uff09\u3092\u4f7f\u7528\u3057\u3066\u53d6\u308a\u9664\u304d\u307e\u3059\u3002File\u3092\u30d5\u30a7\u30e9\u30eb\u306b\u633f\u5165\u3057\u3001\u3057\u3063\u304b\u308a\u3068\u30d5\u30a7\u30e9\u30eb\u306e\u5185\u5074\u306b\u306f\u307e\u308b\u307e\u3067\u5c11\u3057\u56de\u8ee2\u3055\u305b\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u529b\u3092\u52a0\u3048\u306a\u304c\u3089File\u3092\u5de6\u53f3\u306b\u5c11\u3057\u52d5\u304b\u3057\u3001\u30d5\u30a7\u30e9\u30eb\u3092\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u304b\u3089\u53d6\u308a\u9664\u304d\u307e\u3059\u3002\u30d5\u30a7\u30e9\u30eb\u304c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u90e8\u5206\u306b\u4e00\u90e8\u6b8b\u3063\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3001\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u5206\u89e3\u3057\u3066\u3059\u3079\u3066\u306e\u90e8\u54c1\u3092\u70b9\u691c\u3057\u3001\u30d5\u30a7\u30e9\u30eb\u3092\u304d\u3061\u3093\u3068\u53d6\u308a\u9664\u3044\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4fdd\u7ba1\u4e2d\u306e\u56fa\u5b9a\u76f8\u306e\u9178\u5316\u3092\u9632\u3050\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u30bb\u30d7\u30bf\u30e0\u306b\u633f\u5165\u3057\u307e\u3059\u3002\u30dd\u30ea\u30de\u30fc\u306e\u640d\u50b7\u3092\u907f\u3051\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306f\u5fc5\u305a\u5143\u306e\u7bb1\u306b\u5165\u308c\u3001\u65e5\u5149\u3084\u86cd\u5149\u706f\u3092\u907f\u3051\u3066\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u7279\u306b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12423\" target=\"_blank\" rel=\"noopener\">Rtx-Wax<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10968\" target=\"_blank\" rel=\"noopener\">Rtx-624<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/16094\" target=\"_blank\" rel=\"noopener\">Rxi-1301Sil MS<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/13868\" target=\"_blank\" rel=\"noopener\">Rxi-624Sil MS<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10623\" target=\"_blank\" rel=\"noopener\">Stabilwax<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/16023\" target=\"_blank\" rel=\"noopener\">Rtx-1301<\/a>\u3001\u304a\u3088\u3073 <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12023\" target=\"_blank\" rel=\"noopener\">Rtx-1701<\/a>\u30ab\u30e9\u30e0\uff08\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304a\u3088\u3073\u30b7\u30a2\u30ce\u30b7\u30ea\u30b3\u30f3\u30dd\u30ea\u30de\u30fc\uff09\u306f\u3001\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u3044\u305f\u3081\u3001\u5fc5\u305a\u906e\u5149\u3057\u3066\u4fdd\u5b58\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>C. \u6c5a\u67d3\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u4fdd\u8b77<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0d\u63ee\u767a\u6027\u3001\u307e\u305f\u306f\u9ad8\u5206\u5b50\u91cf\u306e\u6b8b\u7559\u7269\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u56fa\u5b9a\u76f8\u3092\u6c5a\u67d3\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9a\u91cf\u7cbe\u5ea6\u3092\u4f4e\u4e0b\u3055\u305b\u3001\u9650\u3089\u308c\u305f\u6ce8\u5165\u56de\u6570\u3067\u30d4\u30fc\u30af\u5206\u96e2\u5ea6\u306e\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u983b\u5ea6\u3092\u6e1b\u3089\u3057\u3001\u5206\u6790\u306e\u52b9\u7387\u3092\u9ad8\u3081\u308b\u305f\u3081\u306b\u3001<strong>\u30a6\u30fc\u30eb\u5165\u308a\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc<\/strong>\u306e\u4f7f\u7528\u3068<strong>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/strong>\u306e\u8a2d\u7f6e\u304c2\u3064\u306e\u5177\u4f53\u7684\u306a\u4e88\u9632\u7b56\u3068\u3057\u3066\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u00a0<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1\u3064\u76ee\u306e\u4e88\u9632\u7b56\u3067\u306f\u3001<strong>\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3057\u305f\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc<\/strong>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u6b8b\u7559\u7269\u3092\u6355\u6349\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3078\u306e\u4fb5\u5165\u3092\u9632\u304e\u307e\u3059\u3002\u3042\u3089\u304b\u3058\u3081\u30a6\u30fc\u30eb\u304c\u5b89\u5b9a\u3057\u3066\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u30d7\u30ea\u30d1\u30c3\u30af\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u304a\u308a\u3001\u6d3b\u6027\u90e8\u4f4d\u304c\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u4e0d\u6d3b\u6027\u5ea6\u304c\u9ad8\u304f\u3001\u4e00\u822c\u7684\u306b\u63a8\u5968\u3055\u308c\u307e\u3059\u3002 \u307e\u305f\u3001\u30e9\u30a4\u30ca\u30fc\u306b\u81ea\u5206\u3067\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3059\u308b\u5834\u5408\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u91dd\u306e\u6700\u5927\u8cab\u901a\u8ddd\u96e2\u306e\u7d041cm\u4e0b\u306b\u3086\u308b\u304f\u8a70\u3081\u305f\u30a6\u30fc\u30eb\u30d7\u30e9\u30b0\u30922cm\u5e45\u7a0b\u5ea6\u3068\u306a\u308b\u3088\u3046\u914d\u7f6e\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5145\u586b\u91cf\u304c\u904e\u5270\u306b\u306a\u308b\u3068\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u306b\u60aa\u5f71\u97ff\u3092\u53ca\u307c\u3059\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u5177\u4f53\u7684\u306a\u5145\u586b\u624b\u9806\u306b\u3064\u3044\u3066\u306f\u3001\u88c5\u7f6e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u3092\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u30d1\u30c3\u30ad\u30f3\u306f\u5438\u7740\u6027\u304c\u9ad8\u304f\u306a\u308a\u3084\u3059\u304f\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30d6\u30ea\u30fc\u30c9\u8981\u56e0\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u63a8\u5968\u3057\u307e\u305b\u3093\u3002\u7279\u306b\u3001\u30e1\u30c1\u30eb\u30b7\u30ea\u30b3\u30fc\u30f3\u30a4\u30f3\u30ec\u30c3\u30c8\u30d1\u30c3\u30ad\u30f3\u3092 Carbowax PEG\u30bf\u30a4\u30d7\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u554f\u984c\u3068\u306a\u308b\u305f\u3081\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2\u3064\u76ee\u306e\u4e88\u9632\u7b56\u306f<strong>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/strong>\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u4e0d\u63ee\u767a\u6027\u306e\u6c5a\u67d3\u7269\u3092\u6355\u6349\u3059\u308b\u3053\u3068\u3067\u5206\u6790\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u5ef6\u3070\u3057\u307e\u3059\u3002Integra-Guard\u30ab\u30e9\u30e0\u306b\u306f\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3068\u540c\u3058\u30c1\u30e5\u30fc\u30d6\u306b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u90e8\u5206\u304c\u3042\u3089\u304b\u3058\u3081\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30c1\u30e5\u30fc\u30d6\u306e\u6700\u521d\u306e5\uff5e10m\u306e\u90e8\u5206\u3067\u3059\u3002\u3053\u306e\u90e8\u5206\u306f\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u56fa\u5b9a\u76f8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u5206\u6790\u30ab\u30e9\u30e0\u3068\u4e00\u4f53\u306b\u306a\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u5206\u6790\u30ab\u30e9\u30e0\uff08\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u90e8\u5206\uff09\u3068\u3068\u3082\u306b\u30d6\u30ea\u30fc\u30c9\u30c6\u30b9\u30c8\u3001\u4e0d\u6d3b\u6027\u5ea6\u30c6\u30b9\u30c8\u304c\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002Integra-Guard\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3082\u30461\u3064\u306e\u5229\u70b9\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u90e8\u5206\u304c\u3042\u3089\u304b\u3058\u3081\u5206\u6790\u30ab\u30e9\u30e0\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u5206\u6790\u30ab\u30e9\u30e0\u3068\u306e\u63a5\u7d9a\u304c\u4e0d\u8981\u3067\u3001\u63a5\u7d9a\u306b\u8d77\u56e0\u3059\u308b\u30ea\u30fc\u30af\u306e\u30ea\u30b9\u30af\u304c\u306a\u3044\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f93\u6765\u578b\u306e\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u30015\uff5e10m\u306e\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u30c1\u30e5\u30fc\u30d6\u3092\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23885\" target=\"_blank\" rel=\"noopener\">SilTite \u00b5-Union<\/a>\u3084 <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20405\" target=\"_blank\" rel=\"noopener\">Press-Tight<\/a>\u306a\u3069\u306e\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u5206\u6790\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\uff08\u30b3\u30cd\u30af\u30bf\u306fRestek\u304b\u3089\u8cfc\u5165\u53ef\u80fd\u3067\u3059\uff09\u3002\u307e\u305f\u3001Restek\u3067\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u5de5\u5834\u3067\u63a5\u7d9a\u3057\u3066\u51fa\u8377\u3059\u308b\u30b5\u30fc\u30d3\u30b9\u3082\u884c\u3063\u3066\u3044\u307e\u3059\u3002\u4e00\u4f53\u578b\u306eIntegra-Guard\u307e\u305f\u306f\u5f93\u6765\u578b\u306e\u5206\u96e2\u578b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u3066\u3082\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u7aef\u304c\u30b5\u30f3\u30d7\u30eb\u6210\u5206\u3067\u6c5a\u67d3\u3055\u308c\u305f\u5834\u5408\u3001\u6c5a\u67d3\u90e8\u4f4d\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u5b9a\u671f\u7684\u306b\u30c8\u30ea\u30df\u30f3\u30b0\u306e\u305f\u3081\u3001\u30ab\u30c3\u30c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Suffix#<\/strong><\/td><td><strong>SilTite \u00b5-Union\u30b3\u30cd\u30af\u30bf\u30fc\u4ed8\u304d\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30fb\u5206\u6790\u30ab\u30e9\u30e0\u7d44\u307f\u7acb\u3066\u6e08\u30bb\u30c3\u30c8<\/strong><\/td><\/tr><tr><td>-370<\/td><td>5 m, 0.18 mm Rxi guard column connected to 0.18 mm ID analytical column<\/td><\/tr><tr><td>-371<\/td><td>5 m, 0.25 mm Rxi guard column connected to 0.25 mm ID analytical column<\/td><\/tr><tr><td>-372<\/td><td>5 m, 0.32 mm Rxi guard column connected to 0.32 mm ID analytical column<\/td><\/tr><tr><td>-373<\/td><td>5 m, 0.53 mm Rxi guard column connected to 0.53 mm ID analytical column<\/td><\/tr><tr><td>-374<\/td><td>10 m, 0.18 mm Rxi guard column connected to 0.18 mm ID analytical column<\/td><\/tr><tr><td>-375<\/td><td>10 m, 0.25 mm Rxi guard column connected to 0.25 mm ID analytical column<\/td><\/tr><tr><td>-376<\/td><td>10 m, 0.32 mm Rxi guard column connected to 0.32 mm ID analytical column<\/td><\/tr><tr><td>-377<\/td><td>10 m, 0.53 mm Rxi guard column connected to 0.53 mm ID analytical column<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>D. \u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u306e\u63a5\u7d9a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b3\u30cd\u30af\u30bf\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u3092\u53d6\u308a\u4ed8\u3051\u308b\u305f\u3081\u306b\u3001\u307e\u305f\u306f\u7834\u640d\u3057\u305f\u5206\u6790\u30ab\u30e9\u30e0\u3092\u4fee\u7406\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u3067\u3042\u308a\u3001Restek\u3067\u306f\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u305f\u9078\u629e\u80a2\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/22159\" target=\"_blank\" rel=\"noopener\">Defined PressFit \u30b3\u30cd\u30af\u30bf<\/a>\u3068 <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20405\" target=\"_blank\" rel=\"noopener\">Press-Tight \u30b3\u30cd\u30af\u30bf<\/a>\u306f\u3001\u4e21\u7aef\u306b\u30c6\u30fc\u30d1\u30fc\u306e\u4ed8\u3044\u305f\u5185\u5f84\u3092\u6301\u3064\u30ac\u30e9\u30b9\u30b3\u30cd\u30af\u30bf\u3067\u3001\u6700\u3082\u7c21\u4fbf\u304b\u3064\u5b89\u4fa1\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3067\u3059\u3002\u30dd\u30ea\u30a4\u30df\u30c9\u6a39\u8102\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20445\" target=\"_blank\" rel=\"noopener\">20445<\/a>\uff09\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30b3\u30cd\u30af\u30bf\u306e\u63a5\u7d9a\u90e8\u3092\u3055\u3089\u306b\u5f37\u5316\u3057\u3001\u63a5\u7d9a\u304c\u5916\u308c\u308b\u30ea\u30b9\u30af\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002 \u307e\u305f\u3001\u5225\u306e\u9078\u629e\u80a2\u3068\u3057\u3066<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23885\" target=\"_blank\" rel=\"noopener\">SilTite \u00b5-Union\u30b3\u30cd\u30af\u30bf<\/a>\u3082\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u91d1\u5c5e\u88fd\u306eSilTite \u00b5-Union\u30b3\u30cd\u30af\u30bf\u306f\u3001\u53d6\u308a\u4ed8\u3051\u304c\u7c21\u5358\u304b\u3064\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u306e\u306a\u3044\u3001\u8010\u5727\u6027\u306e\u9ad8\u3044\u9811\u5065\u306a\u63a5\u7d9a\u3092\u5b9f\u73fe\u3057\u3001\u7279\u306b\u8cea\u91cf\u5206\u6790\u8a08\u3067\u306e\u4f7f\u7528\u306b\u6700\u9069\u3067\u3059\u3002\u307e\u305f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/21386\" target=\"_blank\" rel=\"noopener\">MXT-Union\u30b3\u30cd\u30af\u30bf<\/a>\u3082\u4e00\u822c\u7684\u304b\u3064\u52b9\u679c\u7684\u306a\u9078\u629e\u80a2\u3067\u3001\u7834\u640d\u3057\u306b\u304f\u304f\u3001\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br>\u3055\u3089\u306b\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/21105\" target=\"_blank\" rel=\"noopener\">Vu2 Union\u30b3\u30cd\u30af\u30bf<\/a>\u3084<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20276\" target=\"_blank\" rel=\"noopener\">SeCure \u201dY\u201d \u30b3\u30cd\u30af\u30bf<\/a>\u306f\u3001Press-Tight\u30b3\u30cd\u30af\u30bf\u306e\u30b7\u30f3\u30d7\u30eb\u3055\u3068\u30e1\u30bf\u30eb\u30e6\u30cb\u30aa\u30f3\u306e\u5f37\u5ea6\u3092\u517c\u306d\u5099\u3048\u3066\u304a\u308a\u3001\u6700\u5927400\u2103\u307e\u3067\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u969b\u306f\u3001\u826f\u597d\u306a\u30b7\u30fc\u30eb\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u3092\u304d\u308c\u3044\u306b\u76f4\u89d2\u306b\u5207\u65ad\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u307e\u305f\u3001\u65b0\u305f\u306b\u63a5\u7d9a\u3092\u884c\u3063\u305f\u969b\u306b\u306f\u3001\u5fc5\u305a<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/28500\" target=\"_blank\" rel=\"noopener\">Restek\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/a>\u3067\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>E. \u30b9\u30c6\u30f3\u30ec\u30b9\u30b9\u30c1\u30fc\u30eb\u30c1\u30e5\u30fc\u30d6\u306e\u63a5\u7d9a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">MXT \u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u306b\u306f\u3001\u7279\u5225\u306a\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20536\" target=\"_blank\" rel=\"noopener\">MXT\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30b3\u30cd\u30af\u30bf<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20395\" target=\"_blank\" rel=\"noopener\">MXT\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0 \u201dY\u201d \u30b3\u30cd\u30af\u30bf<\/a>\u306f\u3001Siltek\u51e6\u7406\u304c\u65bd\u3055\u308c\u3001\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u3082\u3001\u30b7\u30b9\u30c6\u30e0\u5185\u306b\u65b0\u305f\u306a\u6d3b\u6027\u90e8\u4f4d\u304c\u51fa\u73fe\u3059\u308b\u3053\u3068\u304c\u306a\u3044\u305f\u3081\u3001\u6d3b\u6027\u5316\u5408\u7269\u306e\u5438\u7740\u3084\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u6291\u3048\u307e\u3059\u3002\u307e\u305f\u3001\u4f7f\u7528\u53ef\u80fd\u6e29\u5ea6\u3082\u9ad8\u304f\u3001\u4e0d\u6d3b\u5316\u5c64\u3092\u52a3\u5316\u3055\u305b\u308b\u3053\u3068\u306a\u304f430\u2103\u307e\u3067\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002Restek\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u4ea4\u63db\u7528\u306e\u3001\u5185\u5f840.28 mm\u306eMXT\u30ab\u30e9\u30e0\u7528\u30d5\u30a7\u30e9\u30eb\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20398\" target=\"_blank\" rel=\"noopener\">20398<\/a>\uff09\u3001\u5185\u5f840.18\/0.25\/0.32 mm\u306eMXT\u30ab\u30e9\u30e0\u7528\u30d5\u30a7\u30e9\u30eb\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20535\" target=\"_blank\" rel=\"noopener\">20535<\/a>\uff09\u3001\u304a\u3088\u3073\u5185\u5f840.53 mm\u306eMXT\u30ab\u30e9\u30e0\u7528\u30d5\u30a7\u30e9\u30eb\uff08cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20399\" target=\"_blank\" rel=\"noopener\">20399<\/a>\uff09\u306e\u3054\u63d0\u4f9b\u304c\u53ef\u80fd\u3067\u3059\u3002MXT\u30ab\u30e9\u30e0\u3068\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ab\u30e9\u30e0\u3068\u306e\u63a5\u7d9a\u306b\u306f\u3001\u5c02\u7528\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/24849\" target=\"_blank\" rel=\"noopener\">Vespel\/\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u30d5\u30a7\u30e9\u30eb<\/a>\u3068\u4e00\u7dd2\u306bMXT\u30b3\u30cd\u30af\u30bf\u3092\u3054\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u306ePress-Tight\u30b3\u30cd\u30af\u30bf\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u306e\u5916\u5074\u306b\u30dd\u30ea\u30a4\u30df\u30c9\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u306a\u3044\u3068\u30ea\u30fc\u30af\u30d5\u30ea\u30fc\u63a5\u7d9a\u304c\u5f97\u3089\u308c\u306a\u3044\u305f\u3081\u3001MXT\u30ab\u30e9\u30e0\u306b\u306f\u4f7f\u7528\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>F. \u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306b\u9ad8\u3044\u30d6\u30ea\u30fc\u30c9\uff08\u30aa\u30fc\u30d0\u30fc\u30ca\u30a4\u30c8\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3067\u6e1b\u5c11\u3057\u306a\u3044\uff09\u3001\u6d3b\u6027\u6210\u5206\u306e\u5438\u7740\u3001\u30d4\u30fc\u30af\u306e\u30c6\u30fc\u30ea\u30f3\u30b0\u3001\u76f8\u5bfe\u4fdd\u6301\u6642\u9593\u306e\u5909\u5316\u304c\u751f\u3058\u305f\u5834\u5408\u306f\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u5fc5\u8981\u3067\u3059\u3002\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u304b\u3089 2 \u30eb\u30fc\u30d7\uff08\u7d04 1 \u30e1\u30fc\u30c8\u30eb\uff09\u3092\u30ab\u30c3\u30c8\u3059\u308b\u3060\u3051\u3067\u3001\u5927\u62b5\u306e\u6c5a\u67d3\u3055\u308c\u305f\u30ab\u30e9\u30e0\u306f\u4fee\u5fa9\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u7aef\u3092\u76ee\u8996\u3067\u78ba\u8a8d\u3057\u3001\u6c5a\u67d3\u30c1\u30e5\u30fc\u30d6\u304c\u3059\u3079\u3066\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u6c5a\u67d3\u5ea6\u306e\u9ad8\u3044\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6027\u80fd\u3092\u8a31\u5bb9\u7bc4\u56f2\u307e\u3067\u56de\u5fa9\u3055\u305b\u308b\u305f\u3081\u306b 2 \u30eb\u30fc\u30d7\u4ee5\u4e0a\u306e\u30ab\u30e9\u30e0\u30ab\u30c3\u30c8\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>G. \u6c34\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u6eb6\u5a92\u306e\u6ce8\u5165<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u306b\u3001\u6c34\u3084\u305d\u306e\u4ed6\u306e\u6eb6\u5a92\u3092\u6ce8\u5165\u3057\u3066\u3082\u3001\u6eb6\u5a92\u304c\u30ab\u30e9\u30e0\u306e\u524d\u6bb5\u306b\u5230\u9054\u3059\u308b\u524d\u306b\u6c17\u5316\u3059\u308c\u3070\uff08\u3059\u306a\u308f\u3061\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u3001\u307e\u305f\u306f\u76f4\u63a5\u6ce8\u5165\u3092\u884c\u3046\u5834\u5408\uff09\u3001\u7d50\u5408\u76f8\u307e\u305f\u306f\u975e\u7d50\u5408\u76f8\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u640d\u50b7\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u30b3\u30fc\u30eb\u30c9\u30aa\u30f3\u30ab\u30e9\u30e0\u30e2\u30fc\u30c9\u307e\u305f\u306f\u52a0\u71b1\u30aa\u30f3\u30ab\u30e9\u30e0\u30e2\u30fc\u30c9\u3067\u4f7f\u7528\u3059\u308b\u3068\u3001\u4f55\u3089\u304b\u306e\u640d\u50b7\u304c\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u640d\u50b7\u306e\u30ea\u30b9\u30af\u3092\u4f4e\u6e1b\u3059\u308b\u305f\u3081\u306b\u3001\u30b3\u30fc\u30eb\u30c9\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6280\u8853\u307e\u305f\u306f\u52a0\u71b1\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6280\u8853\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/13198\" target=\"_blank\" rel=\"noopener\">Rt-2560<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10623\" target=\"_blank\" rel=\"noopener\">Stabilwax<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10823\" target=\"_blank\" rel=\"noopener\">Stabilwax-DB<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/11023\" target=\"_blank\" rel=\"noopener\">Stabilwax-DA<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10708\" target=\"_blank\" rel=\"noopener\">Rtx-2330<\/a>\u3001\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/14023\" target=\"_blank\" rel=\"noopener\">Rtx-225<\/a>\u76f8\u3067\u306e\u6c34\u304a\u3088\u3073\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u4f7f\u7528\u3092\u907f\u3051\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u306b5m\u306eHydroguard\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u308b\u3053\u3068\u3067\u3001\u6c34\u3084\u30e1\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u30c0\u30e1\u30fc\u30b8\u3092\u56de\u907f\u3067\u304d\u307e\u3059\u3002Hydroguard\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u524d\u306b\u6eb6\u5a92\u3092\u6c17\u5316\u3055\u305b\u307e\u3059\u3002\u6c34\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u307e\u305f\u306f\u4ed6\u306e\u6eb6\u5a92\u3092\u6ce8\u5165\u3057\u3066\u3082\u3001\u6ce8\u5165\u30e2\u30fc\u30c9\u306b\u95a2\u4fc2\u306a\u304f\u3001Restek\u304c\u63d0\u4f9b\u3059\u308b\u4ed6\u306e\u56fa\u5b9a\u76f8\u3092\u640d\u50b7\u3059\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A. \u30b9\u30bf\u30f3\u30d0\u30a4\u64cd\u4f5c \u30ab\u30e9\u30e0\u3092\u6570\u65e5\u9593\u4f7f\u7528\u3057\u306a\u3044\u304c\u3001\u88c5\u7f6e\u3092\u30b9\u30bf\u30f3\u30d0\u30a4\u72b6\u614b\u306b\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u306e\u6d41\u91cf\u309210 cc\/min\u306b\u6e1b\u3089\u3057\uff08\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u7bc0\u7d04\u3059\u308b\u305f\u3081\uff09\u3001\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092100 \u2103\uff5e150 \u2103\u306b\u7dad\u6301\u3057\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092\u3084\u3084\u9ad8\u6e29\u306b\u4fdd\u3064\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u3078\u306e\u30bb\u30d7\u30bf\u30e0\u30d6\u30ea\u30fc\u30c9\u306e\u84c4\u7a4d\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30ab\u30e9\u30e0\u4f7f\u7528\u6642\u306e\u904e\u5270\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u5fc5\u8981\u6027\u3092\u4f4e\u6e1b\u3057\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u30b9\u30bf\u30f3\u30d0\u30a4\u72b6\u614b\u306b\u3059\u308b\u3068\u304d\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304c\u5341\u5206\u306b\u4f9b\u7d66\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ab\u30e9\u30e0\u30923\u65e5\u4ee5\u4e0a\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u3059\u3079\u3066\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3057\u3001GC\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u305f\u307e\u307e\u306b\u3059\u308b\u5834\u5408\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u6b62\u3081\u305a\u3001\u5fc5\u305a\u5c11\u91cf\u306e\u30ac\u30b9\u3092\u6d41\u3057\u305f\u72b6\u614b\u3092\u4fdd\u3064\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ac\u30b9\u3082\u6b62\u3081\u308b\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u3082\u30b7\u30b9\u30c6\u30e0\u304b\u3089\u53d6\u308a\u5916\u3059\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002 B. \u30ab\u30e9\u30e0\u306e\u53d6\u308a\u5916\u3057\u3068\u4fdd\u7ba1 GC\u304b\u3089\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u5916\u3057\u307e\u3059\u3002\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3084\u691c\u51fa\u5668\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u30d5\u30a7\u30e9\u30eb\u304c\u6b8b\u3063\u3066\u3044\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u30d5\u30a7\u30e9\u30eb\u304c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u6b8b\u3063\u3066\u3044\u308b\u5834\u5408\u306f\u3001Tapered Needle File \uff08cat.# 20106\uff09\u3092\u4f7f\u7528\u3057\u3066\u53d6\u308a\u9664\u304d\u307e\u3059\u3002File\u3092\u30d5\u30a7\u30e9\u30eb\u306b\u633f\u5165\u3057\u3001\u3057\u3063\u304b\u308a\u3068\u30d5\u30a7\u30e9\u30eb\u306e\u5185\u5074\u306b\u306f\u307e\u308b\u307e\u3067\u5c11\u3057\u56de\u8ee2\u3055\u305b\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u529b\u3092\u52a0\u3048\u306a\u304c\u3089File\u3092\u5de6\u53f3\u306b\u5c11\u3057\u52d5\u304b\u3057\u3001\u30d5\u30a7\u30e9\u30eb\u3092\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u304b\u3089\u53d6\u308a\u9664\u304d\u307e\u3059\u3002\u30d5\u30a7\u30e9\u30eb\u304c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u90e8\u5206\u306b\u4e00\u90e8\u6b8b\u3063\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3001\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u5206\u89e3\u3057\u3066\u3059\u3079\u3066\u306e\u90e8\u54c1\u3092\u70b9\u691c\u3057\u3001\u30d5\u30a7\u30e9\u30eb\u3092\u304d\u3061\u3093\u3068\u53d6\u308a\u9664\u3044\u3066\u304f\u3060\u3055\u3044\u3002 \u4fdd\u7ba1\u4e2d\u306e\u56fa\u5b9a\u76f8\u306e\u9178\u5316\u3092\u9632\u3050\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u7aef\u3092\u30bb\u30d7\u30bf\u30e0\u306b\u633f\u5165\u3057\u307e\u3059\u3002\u30dd\u30ea\u30de\u30fc\u306e\u640d\u50b7\u3092\u907f\u3051\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306f\u5fc5\u305a\u5143\u306e\u7bb1\u306b\u5165\u308c\u3001\u65e5\u5149\u3084\u86cd\u5149\u706f\u3092\u907f\u3051\u3066\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u7279\u306b\u3001Rtx-Wax\u3001Rtx-624\u3001Rxi-1301Sil MS\u3001Rxi-624Sil MS\u3001Stabilwax\u3001Rtx-1301\u3001\u304a\u3088\u3073 Rtx-1701\u30ab\u30e9\u30e0\uff08\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304a\u3088\u3073\u30b7\u30a2\u30ce\u30b7\u30ea\u30b3\u30f3\u30dd\u30ea\u30de\u30fc\uff09\u306f\u3001\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u3044\u305f\u3081\u3001\u5fc5\u305a\u906e\u5149\u3057\u3066\u4fdd\u5b58\u3057\u3066\u304f\u3060\u3055\u3044\u3002 C. \u6c5a\u67d3\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u4fdd\u8b77 \u4e0d\u63ee\u767a\u6027\u3001\u307e\u305f\u306f\u9ad8\u5206\u5b50\u91cf\u306e\u6b8b\u7559\u7269\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u56fa\u5b9a\u76f8\u3092\u6c5a\u67d3\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9a\u91cf\u7cbe\u5ea6\u3092\u4f4e\u4e0b\u3055\u305b\u3001\u9650\u3089\u308c\u305f\u6ce8\u5165\u56de\u6570\u3067\u30d4\u30fc\u30af\u5206\u96e2\u5ea6\u306e\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u983b\u5ea6\u3092\u6e1b\u3089\u3057\u3001\u5206\u6790\u306e\u52b9\u7387\u3092\u9ad8\u3081\u308b\u305f\u3081\u306b\u3001\u30a6\u30fc\u30eb\u5165\u308a\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u306e\u4f7f\u7528\u3068\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u8a2d\u7f6e\u304c2\u3064\u306e\u5177\u4f53\u7684\u306a\u4e88\u9632\u7b56\u3068\u3057\u3066\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u00a0 1\u3064\u76ee\u306e\u4e88\u9632\u7b56\u3067\u306f\u3001\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3057\u305f\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u6b8b\u7559\u7269\u3092\u6355\u6349\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3078\u306e\u4fb5\u5165\u3092\u9632\u304e\u307e\u3059\u3002\u3042\u3089\u304b\u3058\u3081\u30a6\u30fc\u30eb\u304c\u5b89\u5b9a\u3057\u3066\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u30d7\u30ea\u30d1\u30c3\u30af\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u304a\u308a\u3001\u6d3b\u6027\u90e8\u4f4d\u304c\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u4e0d\u6d3b\u6027\u5ea6\u304c\u9ad8\u304f\u3001\u4e00\u822c\u7684\u306b\u63a8\u5968\u3055\u308c\u307e\u3059\u3002 \u307e\u305f\u3001\u30e9\u30a4\u30ca\u30fc\u306b\u81ea\u5206\u3067\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3059\u308b\u5834\u5408\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u91dd\u306e\u6700\u5927\u8cab\u901a\u8ddd\u96e2\u306e\u7d041cm\u4e0b\u306b\u3086\u308b\u304f\u8a70\u3081\u305f\u30a6\u30fc\u30eb\u30d7\u30e9\u30b0\u30922cm\u5e45\u7a0b\u5ea6\u3068\u306a\u308b\u3088\u3046\u914d\u7f6e\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5145\u586b\u91cf\u304c\u904e\u5270\u306b\u306a\u308b\u3068\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u306b\u60aa\u5f71\u97ff\u3092\u53ca\u307c\u3059\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u5177\u4f53\u7684\u306a\u5145\u586b\u624b\u9806\u306b\u3064\u3044\u3066\u306f\u3001\u88c5\u7f6e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002 \u56fa\u5b9a\u76f8\u3092\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3057\u305f\u30d1\u30c3\u30ad\u30f3\u306f\u5438\u7740\u6027\u304c\u9ad8\u304f\u306a\u308a\u3084\u3059\u304f\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30d6\u30ea\u30fc\u30c9\u8981\u56e0\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u63a8\u5968\u3057\u307e\u305b\u3093\u3002\u7279\u306b\u3001\u30e1\u30c1\u30eb\u30b7\u30ea\u30b3\u30fc\u30f3\u30a4\u30f3\u30ec\u30c3\u30c8\u30d1\u30c3\u30ad\u30f3\u3092 Carbowax PEG\u30bf\u30a4\u30d7\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u554f\u984c\u3068\u306a\u308b\u305f\u3081\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002 2\u3064\u76ee\u306e\u4e88\u9632\u7b56\u306f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u4e0d\u63ee\u767a\u6027\u306e\u6c5a\u67d3\u7269\u3092\u6355\u6349\u3059\u308b\u3053\u3068\u3067\u5206\u6790\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u5ef6\u3070\u3057\u307e\u3059\u3002Integra-Guard\u30ab\u30e9\u30e0\u306b\u306f\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3068\u540c\u3058\u30c1\u30e5\u30fc\u30d6\u306b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u90e8\u5206\u304c\u3042\u3089\u304b\u3058\u3081\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30c1\u30e5\u30fc\u30d6\u306e\u6700\u521d\u306e5\uff5e10m\u306e\u90e8\u5206\u3067\u3059\u3002\u3053\u306e\u90e8\u5206\u306f\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u56fa\u5b9a\u76f8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u5206\u6790\u30ab\u30e9\u30e0\u3068\u4e00\u4f53\u306b\u306a\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u5206\u6790\u30ab\u30e9\u30e0\uff08\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u90e8\u5206\uff09\u3068\u3068\u3082\u306b\u30d6\u30ea\u30fc\u30c9\u30c6\u30b9\u30c8\u3001\u4e0d\u6d3b\u6027\u5ea6\u30c6\u30b9\u30c8\u304c\u5b9f\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002Integra-Guard\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3082\u30461\u3064\u306e\u5229\u70b9\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u90e8\u5206\u304c\u3042\u3089\u304b\u3058\u3081\u5206\u6790\u30ab\u30e9\u30e0\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u5206\u6790\u30ab\u30e9\u30e0\u3068\u306e\u63a5\u7d9a\u304c\u4e0d\u8981\u3067\u3001\u63a5\u7d9a\u306b\u8d77\u56e0\u3059\u308b\u30ea\u30fc\u30af\u306e\u30ea\u30b9\u30af\u304c\u306a\u3044\u3053\u3068\u3067\u3059\u3002 \u5f93\u6765\u578b\u306e\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u30015\uff5e10m\u306e\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u30c1\u30e5\u30fc\u30d6\u3092\u3001SilTite \u00b5-Union\u3084 Press-Tight\u306a\u3069\u306e\u30b3\u30cd\u30af\u30bf\u3092\u4f7f\u7528\u3057\u3066\u5206\u6790\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\uff08\u30b3\u30cd\u30af\u30bf\u306fRestek\u304b\u3089\u8cfc\u5165\u53ef\u80fd\u3067\u3059\uff09\u3002\u307e\u305f\u3001Restek\u3067\u306f\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u5de5\u5834\u3067\u63a5\u7d9a\u3057\u3066\u51fa\u8377\u3059\u308b\u30b5\u30fc\u30d3\u30b9\u3082\u884c\u3063\u3066\u3044\u307e\u3059\u3002\u4e00\u4f53\u578b\u306eIntegra-Guard\u307e\u305f\u306f\u5f93\u6765\u578b\u306e\u5206\u96e2\u578b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u3069\u3061\u3089\u3092\u9078\u629e\u3057\u3066\u3082\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u7aef\u304c\u30b5\u30f3\u30d7\u30eb\u6210\u5206\u3067\u6c5a\u67d3\u3055\u308c\u305f\u5834\u5408\u3001\u6c5a\u67d3\u90e8\u4f4d\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u5b9a\u671f\u7684\u306b\u30c8\u30ea\u30df\u30f3\u30b0\u306e\u305f\u3081\u3001\u30ab\u30c3\u30c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 Suffix# SilTite \u00b5-Union\u30b3\u30cd\u30af\u30bf\u30fc\u4ed8\u304d\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30fb\u5206\u6790\u30ab\u30e9\u30e0\u7d44\u307f\u7acb\u3066\u6e08\u30bb\u30c3\u30c8 -370 5 m, 0.18 mm Rxi guard column connected to 0.18 mm ID analytical column -371 5 m, 0.25 mm Rxi guard column&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[809],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2385,2565,2552],"resource-technique":[],"ppma_author":[414],"class_list":["post-44745","post","type-post","status-publish","format-standard","hentry","category-instruction-sheets-ja","product-library-ferrules-fittings-connectors","product-library-ferrules-fittings-connectors-ja","product-library-gas-chromatography-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":809,"label":"Instruction Sheets"}],"product-library":[{"value":2385,"label":"Ferrules, Fittings, Connectors"},{"value":2565,"label":"GC \u30d5\u30a7\u30e9\u30eb\uff5c\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\uff5c\u30b3\u30cd\u30af\u30bf"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":809,"name":"Instruction Sheets","slug":"instruction-sheets-ja","term_group":0,"term_taxonomy_id":809,"taxonomy":"category","description":"","parent":0,"count":204,"filter":"raw","cat_ID":809,"category_count":204,"category_description":"","cat_name":"Instruction Sheets","category_nicename":"instruction-sheets-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44745","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44745"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44745\/revisions"}],"predecessor-version":[{"id":92219,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44745\/revisions\/92219"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44745"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44745"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44745"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44745"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44745"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44745"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44745"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44745"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44745"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}