{"id":44810,"date":"2025-07-31T19:16:52","date_gmt":"2025-07-31T19:16:52","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44810"},"modified":"2025-12-09T15:47:48","modified_gmt":"2025-12-09T15:47:48","slug":"why-are-amines-tailing-on-my-column-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5017-ja\/why-are-amines-tailing-on-my-column-jp","title":{"rendered":"\u30a2\u30df\u30f3\u985e\u304c\u30ab\u30e9\u30e0\u3067\u30c6\u30fc\u30ea\u30f3\u30b0\u3059\u308b\u306e\u306f\u306a\u305c\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30a2\u30df\u30f3\u985e\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u60aa\u304f\u306a\u308b\u539f\u56e0\u306e\u591a\u304f\u306f\u3001\u9178\u6027\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\uff08\u9178\u6027\u6d3b\u6027\u90e8\u4f4d\uff09\u3068\u30a2\u30df\u30f3\u985e\uff08\u5869\u57fa\u6027\u5316\u5408\u7269\uff09\u306e\u76f8\u4e92\u4f5c\u7528\u3067\u3059\u3002\u3053\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u6ce8\u5165\u53e3\u5185\u307e\u305f\u306f\u30ab\u30e9\u30e0\u5185\u3067\u8d77\u3053\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u3092\u52b9\u679c\u7684\u306b\u89e3\u6c7a\u3059\u308b\u65b9\u6cd5\u306f\u3001\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3068\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u00a0<br>Restek\u306f3\u3064\u306e\u6975\u6027\u306e\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30e9\u30a4\u30ca\u30fc\u3068\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30ab\u30e9\u30e0\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\uff1aRtx-Volatile Amine\u30ab\u30e9\u30e0\u3068Rtx-5 Amine\u30ab\u30e9\u30e0\u306f\u4f4e\u6975\u6027\u3001Rtx-35 Amine\u30ab\u30e9\u30e0\u306f\u4e2d\u6975\u6027\u3001Stabilwax-DB\u30ab\u30e9\u30e0\u306f\u9ad8\u6975\u6027\u3067\u3059\u3002\u3044\u305a\u308c\u3082\u5869\u57fa\u6027\u5316\u5408\u7269\u306e\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u4f4e\u6e1b\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30df\u30f3\u985e\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u60aa\u304f\u306a\u308b\u539f\u56e0\u306e\u591a\u304f\u306f\u3001\u9178\u6027\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\uff08\u9178\u6027\u6d3b\u6027\u90e8\u4f4d\uff09\u3068\u30a2\u30df\u30f3\u985e\uff08\u5869\u57fa\u6027\u5316\u5408\u7269\uff09\u306e\u76f8\u4e92\u4f5c\u7528\u3067\u3059\u3002\u3053\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u6ce8\u5165\u53e3\u5185\u307e\u305f\u306f\u30ab\u30e9\u30e0\u5185\u3067\u8d77\u3053\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u3092\u52b9\u679c\u7684\u306b\u89e3\u6c7a\u3059\u308b\u65b9\u6cd5\u306f\u3001\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3068\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u00a0Restek\u306f3\u3064\u306e\u6975\u6027\u306e\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30e9\u30a4\u30ca\u30fc\u3068\u5869\u57fa\u4e0d\u6d3b\u6027\u5316\u30ab\u30e9\u30e0\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\uff1aRtx-Volatile Amine\u30ab\u30e9\u30e0\u3068Rtx-5 Amine\u30ab\u30e9\u30e0\u306f\u4f4e\u6975\u6027\u3001Rtx-35 Amine\u30ab\u30e9\u30e0\u306f\u4e2d\u6975\u6027\u3001Stabilwax-DB\u30ab\u30e9\u30e0\u306f\u9ad8\u6975\u6027\u3067\u3059\u3002\u3044\u305a\u308c\u3082\u5869\u57fa\u6027\u5316\u5408\u7269\u306e\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u4f4e\u6e1b\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2678],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44810","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-capillary-gc-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2678,"label":"FAQ: Capillary GC Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2678,"name":"FAQ: Capillary GC Columns","slug":"faq-capillary-gc-columns","term_group":0,"term_taxonomy_id":2678,"taxonomy":"post_tag","description":"Browse frequently asked questions for capillary GC columns.","parent":0,"count":25,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44810","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44810"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44810\/revisions"}],"predecessor-version":[{"id":72625,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44810\/revisions\/72625"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44810"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44810"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44810"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44810"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44810"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44810"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44810"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44810"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44810"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}