{"id":44818,"date":"2025-07-31T21:05:57","date_gmt":"2025-07-31T21:05:57","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44818"},"modified":"2025-12-09T15:36:57","modified_gmt":"2025-12-09T15:36:57","slug":"can-i-inject-water-onto-my-column-will-it-damage-the-column-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5020-ja\/can-i-inject-water-onto-my-column-will-it-damage-the-column-jp","title":{"rendered":"GC\u30ab\u30e9\u30e0\u306b\u6c34\u3092\u6ce8\u5165\u3057\u3066\u3082\u5927\u4e08\u592b\uff1f \u30ab\u30e9\u30e0\u52a3\u5316\u306e\u30ea\u30b9\u30af\u306f\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u975e\u6975\u6027\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u3001\u308f\u305a\u304b\u306a\u91cf\u306e\u6c34\uff08\u6eb6\u5a92\uff09\u3092\u6ce8\u5165\u3057\u3066\u3082\u3001\u6db2\u76f8\u306b\u640d\u50b7\u304c\u751f\u3058\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u4e2d\u6975\u6027\u304a\u3088\u3073\u9ad8\u6975\u6027\u306e\u30ab\u30e9\u30e0\u306b\u95a2\u3057\u3066\u306f\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001GC\u30ab\u30e9\u30e0\u306b\u6c34\u3092\u6eb6\u5a92\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u969b\u306b\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6c34\u306f\u3001\u30ab\u30e9\u30e0\u306b\u5165\u308b\u524d\u306b\u5b8c\u5168\u306b\u6c17\u5316\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u5185\u3067\u6c34\u304c\u518d\u51dd\u7e2e\u3057\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>GC\u30aa\u30fc\u30d6\u30f3\u306e\u6e29\u5ea6\u304c\u4f4e\u3059\u304e\u3066\u6c34\u84b8\u6c17\u304c\u51dd\u7e2e\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u5834\u5408\uff1a\n<ul class=\"wp-block-list\">\n<li>Polar-Deactivated guard column\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u6c34\u304c\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u524d\u306b\u5b8c\u5168\u306b\u6c17\u5316\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>\u30b3\u30fc\u30eb\u30c9\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u307e\u305f\u306f\u52a0\u71b1\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u30e2\u30fc\u30c9\u306f\u4f7f\u7528\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002\u6eb6\u5a92\u304c\u30ab\u30e9\u30e0\u306b\u5165\u308b\u524d\u306b\u6c17\u5316\u3059\u308b\u6ce8\u5165\u30e2\u30fc\u30c9\uff08\u30b9\u30d7\u30ea\u30c3\u30c8\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u3001\u307e\u305f\u306f\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\uff09\u306e\u307f\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u6ce8\u5165\u306f1uL\u4ee5\u4e0b\u3068\u3057\u307e\u3059\u3002\u4f53\u7a4d\u304c\u5927\u304d\u3044\u3068\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u767a\u751f\u3057\u3001\u6eb6\u5a92\u306e\u81a8\u5f35\u4f53\u7a4d\u304c\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u3092\u8d85\u3048\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u518d\u73fe\u6027\u306e\u60aa\u3055\u304a\u3088\u3073\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u306e\u767a\u751f\u306b\u3064\u306a\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/articles\/restek-capillary-column-installation-guide\" target=\"_blank\" rel=\"noopener\">Capillary Column Installation Guide<\/a>\u306b\u8a73\u7d30\u306a\u60c5\u5831\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\uff08<a href=\"https:\/\/www.restek.com\/articles\/restek-capillary-column-installation-guide-section-i-brief-installation-procedure\/#jp\" target=\"_blank\" rel=\"noopener\">\u300cGC\u30ab\u30e9\u30e0\u53d6\u4ed8\u3051\u624b\u9806\u300d<\/a>\u306e\u9805\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u975e\u6975\u6027\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u3001\u308f\u305a\u304b\u306a\u91cf\u306e\u6c34\uff08\u6eb6\u5a92\uff09\u3092\u6ce8\u5165\u3057\u3066\u3082\u3001\u6db2\u76f8\u306b\u640d\u50b7\u304c\u751f\u3058\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u4e2d\u6975\u6027\u304a\u3088\u3073\u9ad8\u6975\u6027\u306e\u30ab\u30e9\u30e0\u306b\u95a2\u3057\u3066\u306f\u7570\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001GC\u30ab\u30e9\u30e0\u306b\u6c34\u3092\u6eb6\u5a92\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u969b\u306b\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002 Capillary Column Installation Guide\u306b\u8a73\u7d30\u306a\u60c5\u5831\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u300cGC\u30ab\u30e9\u30e0\u53d6\u4ed8\u3051\u624b\u9806\u300d\u306e\u9805\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\uff09\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2678],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44818","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-capillary-gc-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2678,"label":"FAQ: Capillary GC Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2678,"name":"FAQ: Capillary GC Columns","slug":"faq-capillary-gc-columns","term_group":0,"term_taxonomy_id":2678,"taxonomy":"post_tag","description":"Browse frequently asked questions for capillary GC columns.","parent":0,"count":25,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44818"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44818\/revisions"}],"predecessor-version":[{"id":72572,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44818\/revisions\/72572"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44818"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44818"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44818"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44818"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44818"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44818"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}