{"id":44837,"date":"2025-07-31T21:13:38","date_gmt":"2025-07-31T21:13:38","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44837"},"modified":"2025-12-09T16:05:29","modified_gmt":"2025-12-09T16:05:29","slug":"can-i-order-a-capillary-column-in-a-column-cage-to-fit-my-small-gc-oven-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5024-ja\/can-i-order-a-capillary-column-in-a-column-cage-to-fit-my-small-gc-oven-jp","title":{"rendered":"\u5c0f\u578bGC\u30aa\u30fc\u30d6\u30f3\u306b\u5408\u3046\u3088\u3046\u306a\u30ab\u30e9\u30e0\u30b1\u30fc\u30b8\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u6ce8\u6587\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u306f\u3044\u3002\u975e\u6a19\u6e96\u306eGC\u30aa\u30fc\u30d6\u30f3\u3084\u30dd\u30fc\u30bf\u30d6\u30ebGC\u30aa\u30fc\u30d6\u30f3\u7528\u306b\u3001\u3044\u304f\u3064\u304b\u306e\u7279\u5225\u306a\u5c0f\u578b\u30b1\u30fc\u30b8\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u00a0<br>\u3053\u308c\u3089\u306e\u7279\u5225\u306a\u4ed5\u69d8\u3067\u306e\u3054\u6ce8\u6587\u3092\u3054\u5e0c\u671b\u306e\u5834\u5408\u306f\u3001\u30ab\u30b9\u30bf\u30de\u30fc\u30b5\u30fc\u30d3\u30b9\u90e8\u9580\uff08RestekTokyo@restek.com\uff09\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Agilent6850\u88c5\u7f6e\u7528\u306e5\u30a4\u30f3\u30c1\u30b1\u30fc\u30b8\u30ab\u30e9\u30e0\u3092\u6ce8\u6587\u3059\u308b\u306b\u306f\u3001\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u672b\u5c3e\u306b\u30fc6850\u3092\u8ffd\u52a0\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u5916\u5f843 1\/2\u201d\u306eMXT\u30ab\u30e9\u30e0\u3092\u6ce8\u6587\u3059\u308b\u306b\u306f\u3001\u30ab\u30e9\u30e0\u306e\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u672b\u5c3e\u306b\u30fc273\u3092\u8ffd\u52a0\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3044\u3002\u975e\u6a19\u6e96\u306eGC\u30aa\u30fc\u30d6\u30f3\u3084\u30dd\u30fc\u30bf\u30d6\u30ebGC\u30aa\u30fc\u30d6\u30f3\u7528\u306b\u3001\u3044\u304f\u3064\u304b\u306e\u7279\u5225\u306a\u5c0f\u578b\u30b1\u30fc\u30b8\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u00a0\u3053\u308c\u3089\u306e\u7279\u5225\u306a\u4ed5\u69d8\u3067\u306e\u3054\u6ce8\u6587\u3092\u3054\u5e0c\u671b\u306e\u5834\u5408\u306f\u3001\u30ab\u30b9\u30bf\u30de\u30fc\u30b5\u30fc\u30d3\u30b9\u90e8\u9580\uff08RestekTokyo@restek.com\uff09\u307e\u3067\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2678],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44837","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-capillary-gc-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2678,"label":"FAQ: Capillary GC Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2678,"name":"FAQ: Capillary GC Columns","slug":"faq-capillary-gc-columns","term_group":0,"term_taxonomy_id":2678,"taxonomy":"post_tag","description":"Browse frequently asked questions for capillary GC columns.","parent":0,"count":25,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44837"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44837\/revisions"}],"predecessor-version":[{"id":72689,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44837\/revisions\/72689"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44837"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44837"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44837"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44837"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44837"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44837"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}