{"id":44861,"date":"2025-07-22T21:33:55","date_gmt":"2025-07-22T21:33:55","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44861"},"modified":"2026-07-30T06:22:50","modified_gmt":"2026-07-30T06:22:50","slug":"how-can-i-troubleshoot-pressure-problems-in-my-gas-standard-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5006-ja\/how-can-i-troubleshoot-pressure-problems-in-my-gas-standard-jp","title":{"rendered":"\u6821\u6b63\u7528\u30ac\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5727\u529b\u554f\u984c\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u65b9\u6cd5\u3092\u6559\u3048\u3066\u304f\u3060\u3055\u3044\u3002"},"content":{"rendered":"\n<p class=\"has-medium-font-size wp-block-paragraph\">\u6821\u6b63\u7528\u30ac\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5727\u529b\u554f\u984c\u3067\u6700\u3082\u983b\u7e41\u306b\u304a\u3053\u308b\u306e\u304c\u3001\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c\u5727\u529b\u5024\u3092\u793a\u3055\u306a\u3044\u3053\u3068\u3067\u3059\u3002\u554f\u984c\u306e\u539f\u56e0\u304c\u3069\u3053\u306b\u3042\u308b\u306e\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u3092\u73fe\u884c\u306e\u30b7\u30ea\u30f3\u30c0\u30fc\u304b\u3089\u53d6\u308a\u5916\u3057\u3001\u78ba\u5b9f\u306b\u5727\u529b\u306e\u3042\u308b\u300c<strong>\u826f\u597d\u306a<\/strong>\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u306b\u63a5\u7d9a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c \u300c<strong>\u826f\u597d\u306a<\/strong>\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u3067\u5727\u529b\u5024\u3092<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">\u793a\u3059<\/mark>\u5834\u5408\u3001\u554f\u984c\u306f\u73fe\u884c\u306e\u30b7\u30ea\u30f3\u30c0\u30fc\u306b\u3042\u308a\u3001\u7a7a\u3067\u3042\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c \u300c<strong>\u826f\u597d\u306a<\/strong>\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u3067\u5727\u529b\u5024\u3092<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-1-color\">\u793a\u3055\u306a\u3044<\/mark>\u5834\u5408\u3001\u554f\u984c\u306f\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u306b\u3042\u308a\u3001\u4fee\u7406\u307e\u305f\u306f\u4ea4\u63db\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6821\u6b63\u7528\u30ac\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u5727\u529b\u554f\u984c\u3067\u6700\u3082\u983b\u7e41\u306b\u304a\u3053\u308b\u306e\u304c\u3001\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c\u5727\u529b\u5024\u3092\u793a\u3055\u306a\u3044\u3053\u3068\u3067\u3059\u3002\u554f\u984c\u306e\u539f\u56e0\u304c\u3069\u3053\u306b\u3042\u308b\u306e\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u3092\u73fe\u884c\u306e\u30b7\u30ea\u30f3\u30c0\u30fc\u304b\u3089\u53d6\u308a\u5916\u3057\u3001\u78ba\u5b9f\u306b\u5727\u529b\u306e\u3042\u308b\u300c\u826f\u597d\u306a\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u306b\u63a5\u7d9a\u3057\u307e\u3059\u3002 \u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c \u300c\u826f\u597d\u306a\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u3067\u5727\u529b\u5024\u3092\u793a\u3059\u5834\u5408\u3001\u554f\u984c\u306f\u73fe\u884c\u306e\u30b7\u30ea\u30f3\u30c0\u30fc\u306b\u3042\u308a\u3001\u7a7a\u3067\u3042\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3067\u3059\u3002 \u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u304c \u300c\u826f\u597d\u306a\u300d\u30b7\u30ea\u30f3\u30c0\u30fc\u3067\u5727\u529b\u5024\u3092\u793a\u3055\u306a\u3044\u5834\u5408\u3001\u554f\u984c\u306f\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u306b\u3042\u308a\u3001\u4fee\u7406\u307e\u305f\u306f\u4ea4\u63db\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804,23],"tags":[2721,2721],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2560,2579,2554],"resource-technique":[],"ppma_author":[2814,2814],"class_list":["post-44861","post","type-post","status-publish","format-standard","hentry","category-faq-ja","category-faq","tag-frequently-asked-questions-reference-standards-japan","product-library-gas-standards-accessories-ja","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"},{"value":23,"label":"FAQ"}],"post_tag":[{"value":2721,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard"},{"value":2721,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard"}],"product-library":[{"value":2560,"label":"\u30ac\u30b9\u6821\u6b63\u7528\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\uff5c\u30a2\u30af\u30bb\u30b5\u30ea"},{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0},{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2721,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard","slug":"frequently-asked-questions-reference-standards-japan","term_group":0,"term_taxonomy_id":2721,"taxonomy":"post_tag","description":"","parent":0,"count":58,"filter":"raw"},{"term_id":2721,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09\uff1a Reference Standard","slug":"frequently-asked-questions-reference-standards-japan","term_group":0,"term_taxonomy_id":2721,"taxonomy":"post_tag","description":"","parent":0,"count":58,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44861"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44861\/revisions"}],"predecessor-version":[{"id":99896,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44861\/revisions\/99896"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44861"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44861"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44861"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44861"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44861"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44861"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}