{"id":44961,"date":"2025-07-30T21:59:49","date_gmt":"2025-07-30T21:59:49","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44961"},"modified":"2025-12-09T15:39:46","modified_gmt":"2025-12-09T15:39:46","slug":"sale-of-components-of-the-lpgc-column-kit-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5123-ja\/sale-of-components-of-the-lpgc-column-kit-jp","title":{"rendered":"LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u69cb\u6210\u90e8\u54c1\u306f\u500b\u5225\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u304b\uff1f\u307e\u305f\u3001\u305d\u308c\u3089\u3092\u81ea\u5206\u3067\u63a5\u7d9a\u3059\u308b\u3053\u3068\u306f\u53ef\u80fd\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001\u305d\u306e\u69cb\u6210\u90e8\u54c1\u3092\u500b\u5225\u306b\u8ca9\u58f2\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u307e\u305f\u3001\u5404\u90e8\u54c1\u3092\u30e6\u30fc\u30b6\u30fc\u306e\u7686\u3055\u3093\u304c\u63a5\u7d9a\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u3053\u308c\u306f\u3001LPGC-MS\u5c02\u7528\u306e\u30ad\u30c3\u30c8\u306f\u5de5\u5834\u3067\u6b63\u78ba\u306b\u7d44\u307f\u7acb\u3066\u3089\u308c\u305f\u3082\u306e\u3067\u3042\u308a\u3001\u5404\u63a5\u7d9a\u90e8\u5206\u304c\u9ad8\u3044\u4fe1\u983c\u6027\u3068\u6c17\u5bc6\u6027\u3092\u4fdd\u3064\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002\u81ea\u5206\u3067\u63a5\u7d9a\u3092\u884c\u3046\u3068\u3001\u6f0f\u308c\u3084\u6027\u80fd\u306e\u4f4e\u4e0b\u304c\u767a\u751f\u3059\u308b\u30ea\u30b9\u30af\u304c\u9ad8\u307e\u308b\u305f\u3081\u3001\u6a19\u6e96\u7684\u306a\u30ab\u30e9\u30e0\u3084\u90e8\u54c1\u3092\u7528\u3044\u3066\u540c\u3058\u6027\u80fd\u3092\u5b9f\u73fe\u3059\u308b\u306e\u306f\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002<br>\u305d\u306e\u305f\u3081\u3001LPGC-MS\u306e\u6027\u80fd\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3059\u305f\u3081\u306b\u306f\u3001\u30e1\u30fc\u30ab\u30fc\u63a8\u5968\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6700\u9069\u306a\u63a5\u7d9a\u304c\u4fdd\u8a3c\u3055\u308c\u3001\u30e9\u30dc\u3067\u306e\u4f7f\u7528\u306b\u304a\u3044\u3066\u3082\u6700\u3082\u4fe1\u983c\u6027\u304c\u9ad8\u304f\u3001\u30b3\u30b9\u30c8\u52b9\u7387\u306e\u826f\u3044\u9078\u629e\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001\u305d\u306e\u69cb\u6210\u90e8\u54c1\u3092\u500b\u5225\u306b\u8ca9\u58f2\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u307e\u305f\u3001\u5404\u90e8\u54c1\u3092\u30e6\u30fc\u30b6\u30fc\u306e\u7686\u3055\u3093\u304c\u63a5\u7d9a\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u3053\u308c\u306f\u3001LPGC-MS\u5c02\u7528\u306e\u30ad\u30c3\u30c8\u306f\u5de5\u5834\u3067\u6b63\u78ba\u306b\u7d44\u307f\u7acb\u3066\u3089\u308c\u305f\u3082\u306e\u3067\u3042\u308a\u3001\u5404\u63a5\u7d9a\u90e8\u5206\u304c\u9ad8\u3044\u4fe1\u983c\u6027\u3068\u6c17\u5bc6\u6027\u3092\u4fdd\u3064\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002\u81ea\u5206\u3067\u63a5\u7d9a\u3092\u884c\u3046\u3068\u3001\u6f0f\u308c\u3084\u6027\u80fd\u306e\u4f4e\u4e0b\u304c\u767a\u751f\u3059\u308b\u30ea\u30b9\u30af\u304c\u9ad8\u307e\u308b\u305f\u3081\u3001\u6a19\u6e96\u7684\u306a\u30ab\u30e9\u30e0\u3084\u90e8\u54c1\u3092\u7528\u3044\u3066\u540c\u3058\u6027\u80fd\u3092\u5b9f\u73fe\u3059\u308b\u306e\u306f\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001LPGC-MS\u306e\u6027\u80fd\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3059\u305f\u3081\u306b\u306f\u3001\u30e1\u30fc\u30ab\u30fc\u63a8\u5968\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6700\u9069\u306a\u63a5\u7d9a\u304c\u4fdd\u8a3c\u3055\u308c\u3001\u30e9\u30dc\u3067\u306e\u4f7f\u7528\u306b\u304a\u3044\u3066\u3082\u6700\u3082\u4fe1\u983c\u6027\u304c\u9ad8\u304f\u3001\u30b3\u30b9\u30c8\u52b9\u7387\u306e\u826f\u3044\u9078\u629e\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2683],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44961","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-low-pressure-gc-ms-lpgc-ms"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2683,"label":"FAQ: Low-Pressure GC-MS (LPGC-MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2683,"name":"FAQ: Low-Pressure GC-MS (LPGC-MS)","slug":"faq-low-pressure-gc-ms-lpgc-ms","term_group":0,"term_taxonomy_id":2683,"taxonomy":"post_tag","description":"Browse frequently asked questions about low-pressure GC-MS (LPGC-MS).","parent":0,"count":48,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44961"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44961\/revisions"}],"predecessor-version":[{"id":72584,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44961\/revisions\/72584"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44961"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44961"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44961"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44961"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44961"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44961"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44961"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44961"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}