{"id":44963,"date":"2025-07-30T21:58:58","date_gmt":"2025-07-30T21:58:58","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44963"},"modified":"2025-12-09T15:55:32","modified_gmt":"2025-12-09T15:55:32","slug":"do-i-need-to-trim-my-restrictor-column-and-if-so-how-often-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5122-ja\/do-i-need-to-trim-my-restrictor-column-and-if-so-how-often-jp","title":{"rendered":"\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304b\uff1f\u3082\u3057\u305d\u3046\u306a\u3089\u3001\u3069\u306e\u304f\u3089\u3044\u306e\u983b\u5ea6\u3067\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30d4\u30fc\u30af\u306e\u5bfe\u79f0\u6027\u3068\u691c\u51fa\u611f\u5ea6\u306e\u4f4e\u4e0b\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u3001\u307e\u305a\u6ce8\u5165\u53e3\u306e\u6d88\u8017\u54c1\u3092\u4ea4\u63db\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u308c\u3067\u3082\u89e3\u6c7a\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u30c8\u30ea\u30df\u30f3\u30b0\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u30c8\u30ea\u30df\u30f3\u30b0\u306e\u9577\u3055\u306f\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u624b\u9806\u306b\u5f93\u3044\u307e\u3059\u304c\u3001\u901a\u5e38\u306f 10 \uff5e 30 cm \u3067\u5341\u5206\u3067\u3059\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u306e\u9577\u3055\u306f\u3001\u6d41\u91cf\u3068\u4fdd\u6301\u6642\u9593\u306b\u5f71\u97ff\u3059\u308b\u305f\u3081\u3001\u30c8\u30ea\u30df\u30f3\u30b0\u3067\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30c1\u30e5\u30fc\u30d6\u304c\u77ed\u304f\u306a\u308a\u3059\u304e\u305f\u5834\u5408\u306f\u3001(a) \u8a2d\u5b9a\u3067\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u306e\u9577\u3055\u3092\u8abf\u6574\u3057\u3066\u6d41\u91cf\u306f\u7dad\u6301\u3059\u308b\u304b\u3001\u307e\u305f\u306f (b) \u30de\u30cb\u30e5\u30a2\u30eb\u3067\u6d41\u91cf\u3092\u8abf\u6574\u3057\u3066\u5143\u306e\u4fdd\u6301\u306b\u5408\u308f\u305b\u308b\u3088\u3046\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d4\u30fc\u30af\u306e\u5bfe\u79f0\u6027\u3068\u691c\u51fa\u611f\u5ea6\u306e\u4f4e\u4e0b\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u3001\u307e\u305a\u6ce8\u5165\u53e3\u306e\u6d88\u8017\u54c1\u3092\u4ea4\u63db\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u305d\u308c\u3067\u3082\u89e3\u6c7a\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u30c8\u30ea\u30df\u30f3\u30b0\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u30c8\u30ea\u30df\u30f3\u30b0\u306e\u9577\u3055\u306f\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u624b\u9806\u306b\u5f93\u3044\u307e\u3059\u304c\u3001\u901a\u5e38\u306f 10 \uff5e 30 cm \u3067\u5341\u5206\u3067\u3059\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u306e\u9577\u3055\u306f\u3001\u6d41\u91cf\u3068\u4fdd\u6301\u6642\u9593\u306b\u5f71\u97ff\u3059\u308b\u305f\u3081\u3001\u30c8\u30ea\u30df\u30f3\u30b0\u3067\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30c1\u30e5\u30fc\u30d6\u304c\u77ed\u304f\u306a\u308a\u3059\u304e\u305f\u5834\u5408\u306f\u3001(a) \u8a2d\u5b9a\u3067\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u306e\u9577\u3055\u3092\u8abf\u6574\u3057\u3066\u6d41\u91cf\u306f\u7dad\u6301\u3059\u308b\u304b\u3001\u307e\u305f\u306f (b) \u30de\u30cb\u30e5\u30a2\u30eb\u3067\u6d41\u91cf\u3092\u8abf\u6574\u3057\u3066\u5143\u306e\u4fdd\u6301\u306b\u5408\u308f\u305b\u308b\u3088\u3046\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2683],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44963","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-low-pressure-gc-ms-lpgc-ms"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2683,"label":"FAQ: Low-Pressure GC-MS (LPGC-MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2683,"name":"FAQ: Low-Pressure GC-MS (LPGC-MS)","slug":"faq-low-pressure-gc-ms-lpgc-ms","term_group":0,"term_taxonomy_id":2683,"taxonomy":"post_tag","description":"Browse frequently asked questions about low-pressure GC-MS (LPGC-MS).","parent":0,"count":48,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44963"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44963\/revisions"}],"predecessor-version":[{"id":72661,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44963\/revisions\/72661"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44963"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44963"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44963"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44963"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44963"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44963"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44963"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44963"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}