{"id":44971,"date":"2025-07-30T21:55:58","date_gmt":"2025-07-30T21:55:58","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44971"},"modified":"2025-12-09T15:39:42","modified_gmt":"2025-12-09T15:39:42","slug":"leak-checking-connections-between-lpgc-column-and-ms-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5118-ja\/leak-checking-connections-between-lpgc-column-and-ms-jp","title":{"rendered":"LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3068\u8cea\u91cf\u5206\u6790\u8a08(MS)\u3092\u63a5\u7d9a\u3059\u308b\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u307e\u305f\u306f\u30e6\u30cb\u30aa\u30f3\u306e\u6f0f\u308c\u3092\u30c1\u30a7\u30c3\u30af\u3059\u308b\u826f\u3044\u65b9\u6cd5\u306f\u3042\u308a\u307e\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u521d\u306b\u3001\u5927\u304d\u306a\u30ea\u30fc\u30af\u3092\u7279\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u7528\u3044\u3066\u52a0\u5727\u30dd\u30a4\u30f3\u30c8\uff08\u30a4\u30f3\u30ec\u30c3\u30c8\u306a\u3069\uff09\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u3092\u7834\u58ca\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u5927\u304d\u306a\u30ea\u30fc\u30af\u3092\u9664\u53bb\u3057\u305f\u5f8c\u3001\u8cea\u91cf\u5206\u6790\u8a08(MS)\u3092\u4f7f\u7528\u3057\u3066\u5c0f\u3055\u306a\u30ea\u30fc\u30af\u306e\u5b58\u5728\u3092\u691c\u51fa\u3057\u307e\u3059\u3002\u8cea\u91cf\u5206\u6790\u8a08(MS)\u306f\u5c0f\u3055\u306a\u30ea\u30fc\u30af\u3092\u7279\u5b9a\u3059\u308b\u306e\u306b\u6709\u52b9\u306a\u65b9\u6cd5\u3067\u3059\u304c\u3001\u30ea\u30fc\u30af\u306e\u5834\u6240\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u3084\u3001\u30ab\u30e9\u30e0\u3068\u8cea\u91cf\u5206\u6790\u8a08\u306e\u9593\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u3088\u3046\u306b\u3001\u771f\u7a7a\u306e\u5f71\u97ff\u304c\u5f37\u3044\u30dd\u30a4\u30f3\u30c8\u3067\u306f\u3001\u4f55\u3089\u304b\u306e\u300c\u30a8\u30a2\u30fc\u7f36\u300d\uff08\u4e00\u822c\u7684\u306b\u30ad\u30fc\u30dc\u30fc\u30c9\u306e\u30db\u30b3\u30ea\u53d6\u308a\u306b\u4f7f\u7528\u3055\u308c\u308b\uff09\u3092\u4f7f\u7528\u3057\u305f\u30ea\u30fc\u30af\u78ba\u8a8d\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u30a8\u30a2\u30fc\u7f36\u306b\u306f\u4e00\u822c\u7684\u306b\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u8cea\u91cf\u5206\u6790\u8a08(MS)\u3067\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u30e2\u30cb\u30bf\u30fc\u304c\u53ef\u80fd\u3067\u3059\u3002\u6f0f\u308c\u304c\u7591\u308f\u308c\u308b\u63a5\u7d9a\u90e8\u306e\u8fd1\u304f\u3067\u30a8\u30a2\u30fc\u7f36\u3092\u77ed\u6642\u9593\u30b9\u30d7\u30ec\u30fc\u3059\u308b\u3068\u3001\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u7531\u6765\u306e\u95a2\u9023\u3059\u308bm\/z\u30a4\u30aa\u30f3\u304c\u4e0a\u6607\u3059\u308b\u306e\u3067\u3001\u6f0f\u308c\u306e\u5b58\u5728\u3068\u5834\u6240\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6700\u521d\u306b\u3001\u5927\u304d\u306a\u30ea\u30fc\u30af\u3092\u7279\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u7528\u3044\u3066\u52a0\u5727\u30dd\u30a4\u30f3\u30c8\uff08\u30a4\u30f3\u30ec\u30c3\u30c8\u306a\u3069\uff09\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u30d5\u30a3\u30e9\u30e1\u30f3\u30c8\u3092\u7834\u58ca\u3059\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u5927\u304d\u306a\u30ea\u30fc\u30af\u3092\u9664\u53bb\u3057\u305f\u5f8c\u3001\u8cea\u91cf\u5206\u6790\u8a08(MS)\u3092\u4f7f\u7528\u3057\u3066\u5c0f\u3055\u306a\u30ea\u30fc\u30af\u306e\u5b58\u5728\u3092\u691c\u51fa\u3057\u307e\u3059\u3002\u8cea\u91cf\u5206\u6790\u8a08(MS)\u306f\u5c0f\u3055\u306a\u30ea\u30fc\u30af\u3092\u7279\u5b9a\u3059\u308b\u306e\u306b\u6709\u52b9\u306a\u65b9\u6cd5\u3067\u3059\u304c\u3001\u30ea\u30fc\u30af\u306e\u5834\u6240\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u3084\u3001\u30ab\u30e9\u30e0\u3068\u8cea\u91cf\u5206\u6790\u8a08\u306e\u9593\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u3088\u3046\u306b\u3001\u771f\u7a7a\u306e\u5f71\u97ff\u304c\u5f37\u3044\u30dd\u30a4\u30f3\u30c8\u3067\u306f\u3001\u4f55\u3089\u304b\u306e\u300c\u30a8\u30a2\u30fc\u7f36\u300d\uff08\u4e00\u822c\u7684\u306b\u30ad\u30fc\u30dc\u30fc\u30c9\u306e\u30db\u30b3\u30ea\u53d6\u308a\u306b\u4f7f\u7528\u3055\u308c\u308b\uff09\u3092\u4f7f\u7528\u3057\u305f\u30ea\u30fc\u30af\u78ba\u8a8d\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u30a8\u30a2\u30fc\u7f36\u306b\u306f\u4e00\u822c\u7684\u306b\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u8cea\u91cf\u5206\u6790\u8a08(MS)\u3067\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u30e2\u30cb\u30bf\u30fc\u304c\u53ef\u80fd\u3067\u3059\u3002\u6f0f\u308c\u304c\u7591\u308f\u308c\u308b\u63a5\u7d9a\u90e8\u306e\u8fd1\u304f\u3067\u30a8\u30a2\u30fc\u7f36\u3092\u77ed\u6642\u9593\u30b9\u30d7\u30ec\u30fc\u3059\u308b\u3068\u3001\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u7531\u6765\u306e\u95a2\u9023\u3059\u308bm\/z\u30a4\u30aa\u30f3\u304c\u4e0a\u6607\u3059\u308b\u306e\u3067\u3001\u6f0f\u308c\u306e\u5b58\u5728\u3068\u5834\u6240\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2718],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-44971","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-frequently-asked-questions-low-pressure-gc-ms-lpgc-ms-japan"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2718,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff1a\u4f4e\u5727GC-MS (LPGC-MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2718,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff1a\u4f4e\u5727GC-MS (LPGC-MS)","slug":"frequently-asked-questions-low-pressure-gc-ms-lpgc-ms-japan","term_group":0,"term_taxonomy_id":2718,"taxonomy":"post_tag","description":"","parent":0,"count":48,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44971"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44971\/revisions"}],"predecessor-version":[{"id":72583,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44971\/revisions\/72583"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44971"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44971"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44971"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44971"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44971"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44971"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44971"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44971"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}