{"id":44976,"date":"2025-07-30T21:54:25","date_gmt":"2025-07-30T21:54:25","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44976"},"modified":"2026-01-24T03:32:24","modified_gmt":"2026-01-24T03:32:24","slug":"settings-to-implement-lpgc-ms-in-my-lab-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5116-ja\/settings-to-implement-lpgc-ms-in-my-lab-jp","title":{"rendered":"\u30e9\u30dc\u306bLPGC-MS\u3092\u5c0e\u5165\u3059\u308b\u306b\u306f\u3001GC-MS\u88c5\u7f6e\u3084\u30b7\u30b9\u30c6\u30e0\u306e\u8a2d\u5b9a\u306b\u3069\u306e\u3088\u3046\u306a\u5909\u66f4\u304c\u5fc5\u8981\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">LPGC-MS\u3092\u63a1\u7528\u3059\u308b\u969b\u306b\u5fc5\u8981\u3068\u306a\u308b\u4e3b\u306a\u5909\u66f4\u70b9\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u308c\u3089\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u3061\u3089\u306e<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3505-ja\/japanese-an-introduction-to-low-pressure-gc-ms-lpgc-ms\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNAR3505-JA\/japanese-an-introduction-to-low-pressure-gc-ms-lpgc-ms\">\u6280\u8853\u8a18\u4e8b<\/a>\u3067\u8aac\u660e\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>LPGC \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u53d6\u308a\u4ed8\u3051\u308b\u969b\u3001LPGC \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3068MS\u306e\u63a5\u7d9a\u306b\u306f\u3001\u5185\u5f84 0.53 mm \u306e\u30ab\u30e9\u30e0\u306b\u306f\u5185\u5f84 0.8 mm \u306e Vespel\/graphite\u30d5\u30a7\u30e9\u30eb\u3092\u3001\u5185\u5f84 0.32 mm \u306e\u30ab\u30e9\u30e0\u306b\u306f\u5185\u5f84 0.5 mm \u306e Vespel\/graphite\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u300260:40 Vespel\/graphite\u30d5\u30a7\u30e9\u30eb\u304c\u3042\u308c\u3070\u3001\u305d\u3061\u3089\u306e\u4f7f\u7528\u3092\u63a8\u5968\u3057\u307e\u3059\u3002LPGC \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u5074\uff08\u30a4\u30f3\u30ec\u30c3\u30c8\uff09\u306b\u306f\u3001\u5f93\u6765\u306e\u5185\u5f84 0.25 mm \u306e\u30ab\u30e9\u30e0\u306b\u4f7f\u7528\u3055\u308c\u308b\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u88c5\u7f6e\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b LPGC \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u8a2d\u5b9a\u3059\u308b\u969b\u306f\u3001\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u90e8\u5206\u306e\u30b5\u30a4\u30ba\u3060\u3051\u3092\u5165\u529b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u56fa\u5b9a\u76f8\u819c\u539a\uff08df\uff09\u306b\u5206\u6790\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u819c\u539a\u3082\u8a2d\u5b9a\u3067\u304d\u307e\u3059\u304c\u3001\u88c5\u7f6e\u306e\u6d41\u91cf\u8a08\u7b97\u306b\u307b\u3068\u3093\u3069\u5f71\u97ff\u3057\u307e\u305b\u3093\u3002<\/li>\n\n\n\n<li>\u5206\u6790\u901f\u5ea6\u3092\u6700\u5927\u306b\u3059\u308b\u306b\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u306e\u6607\u6e29\u901f\u5ea6\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u9ad8\u304f\u8a2d\u5b9a\u3059\u308b\u3068\u826f\u3044\u3067\u3057\u3087\u3046\u3002\u305f\u3060\u3057\u3001GC\u30aa\u30fc\u30d6\u30f3\u306e\u6700\u5927\u6607\u6e29\u901f\u5ea6\u307e\u305f\u306f\u8cea\u91cf\u5206\u6790\u8a08(MS)\u306e\u6700\u5927\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u8cea\u91cf\u5206\u6790\u8a08(MS)\u306f\u3001LPGC\u30e1\u30bd\u30c3\u30c9\u3067\u4f7f\u7528\u3059\u308b\u6d41\u91cf\u6761\u4ef6\u3067\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u6ce8\u610f\uff1a\u65b0\u3057\u3044 LPGC \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u4fdd\u6301\u6642\u9593\u306e\u78ba\u8a8d\/\u8abf\u6574\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6eb6\u51fa\u9806\u5e8f\u306f\u5909\u308f\u3089\u306a\u304f\u3066\u3082\u3001\u7d76\u5bfe\u4fdd\u6301\u6642\u9593\u304c10\u301c20\u79d2\u7a0b\u5ea6\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u30ad\u30c3\u30c8\u306e\u30a4\u30f3\u30b9\u30c8\u30fc\u30eb\u3068\u6700\u9069\u5316\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/discover.restek.com\/articles\/gnar4241\/quick-start-guide-to-lpgc\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4241\/quick-start-guide-to-lpgc\/\">\u30af\u30a4\u30c3\u30af\u30b9\u30bf\u30fc\u30c8\u30ac\u30a4\u30c9 (\u65e5\u672c\u8a9e\u8a18\u4e8b\u6e96\u5099\u4e2d\uff09<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>LPGC-MS\u3092\u63a1\u7528\u3059\u308b\u969b\u306b\u5fc5\u8981\u3068\u306a\u308b\u4e3b\u306a\u5909\u66f4\u70b9\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u308c\u3089\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u3053\u3061\u3089\u306e\u6280\u8853\u8a18\u4e8b\u3067\u8aac\u660e\u3055\u308c\u3066\u3044\u307e\u3059\u3002 LPGC-MS\u30ad\u30c3\u30c8\u306e\u30a4\u30f3\u30b9\u30c8\u30fc\u30eb\u3068\u6700\u9069\u5316\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u30af\u30a4\u30c3\u30af\u30b9\u30bf\u30fc\u30c8\u30ac\u30a4\u30c9 (\u65e5\u672c\u8a9e\u8a18\u4e8b\u6e96\u5099\u4e2d\uff09\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2718],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[2814],"class_list":["post-44976","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-frequently-asked-questions-low-pressure-gc-ms-lpgc-ms-japan"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2718,"label":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff1a\u4f4e\u5727GC-MS (LPGC-MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2718,"name":"\u3088\u304f\u3042\u308b\u8cea\u554f\uff1a\u4f4e\u5727GC-MS (LPGC-MS)","slug":"frequently-asked-questions-low-pressure-gc-ms-lpgc-ms-japan","term_group":0,"term_taxonomy_id":2718,"taxonomy":"post_tag","description":"","parent":0,"count":48,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44976"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44976\/revisions"}],"predecessor-version":[{"id":84492,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44976\/revisions\/84492"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44976"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44976"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44976"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44976"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44976"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44976"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44976"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44976"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}