{"id":44994,"date":"2025-07-30T21:25:51","date_gmt":"2025-07-30T21:25:51","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=44994"},"modified":"2025-12-09T15:55:43","modified_gmt":"2025-12-09T15:55:43","slug":"4-mm-id-glass-packed-column-recommendations-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5130-ja\/4-mm-id-glass-packed-column-recommendations-jp","title":{"rendered":"\u5185\u5f844mm\u306e\u30ac\u30e9\u30b9\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u304c\u6b32\u3057\u3044\u306e\u3067\u3059\u304c\u3001\u63d0\u4f9b\u3055\u308c\u3066\u3044\u306a\u3044\u3088\u3046\u3067\u3059\u3002\u4ee3\u66ff\u3048\u54c1\u306f\u3042\u308a\u307e\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u3057\u3066\u3044\u308b\u30e1\u30bd\u30c3\u30c9\u3084\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u3088\u3063\u3066\u306f\u3001Restek\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6280\u8853\u3067\u3042\u308bSilcoSmooth\u51e6\u7406\u3057\u305f\u4e0d\u52d5\u614b\u5316\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u306e\u67d4\u8edf\u6027\u3068\u8010\u4e45\u6027\u3092\u878d\u5408\u3057\u305f\u3082\u306e\u3067\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u306e\u4e0d\u6d3b\u6027\u3055\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u5185\u5f843.1mm\uff08\u5916\u5f843\/16\u30a4\u30f3\u30c1\uff09\u306eSilcoSmooth\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u306f\u3001\u5185\u5f844mm\u306e\u30ac\u30e9\u30b9\u30ab\u30e9\u30e0\u3068\u975e\u5e38\u306b\u8fd1\u3057\u3044\u6027\u80fd\u3092\u63d0\u4f9b\u3057\u3001\u3088\u308a\u7834\u640d\u306e\u5371\u967a\u304c\u5c11\u306a\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u305f\u304c\u3063\u3066\u3001\u3082\u3057\u30e1\u30bd\u30c3\u30c9\u304c\u30ac\u30e9\u30b9\u30a8\u30f3\u30d7\u30c6\u30a3\u3092\u6307\u5b9a\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001SilcoSmooth\u51e6\u7406\u3057\u305f\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u306f\u512a\u308c\u305f\u4ee3\u66ff\u624b\u6bb5\u3068\u306a\u308a\u5f97\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4f7f\u7528\u3057\u3066\u3044\u308b\u30e1\u30bd\u30c3\u30c9\u3084\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u3088\u3063\u3066\u306f\u3001Restek\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6280\u8853\u3067\u3042\u308bSilcoSmooth\u51e6\u7406\u3057\u305f\u4e0d\u52d5\u614b\u5316\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u306e\u67d4\u8edf\u6027\u3068\u8010\u4e45\u6027\u3092\u878d\u5408\u3057\u305f\u3082\u306e\u3067\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u306e\u4e0d\u6d3b\u6027\u3055\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u5185\u5f843.1mm\uff08\u5916\u5f843\/16\u30a4\u30f3\u30c1\uff09\u306eSilcoSmooth\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u306f\u3001\u5185\u5f844mm\u306e\u30ac\u30e9\u30b9\u30ab\u30e9\u30e0\u3068\u975e\u5e38\u306b\u8fd1\u3057\u3044\u6027\u80fd\u3092\u63d0\u4f9b\u3057\u3001\u3088\u308a\u7834\u640d\u306e\u5371\u967a\u304c\u5c11\u306a\u3044\u3067\u3059\u3002 \u3057\u305f\u304c\u3063\u3066\u3001\u3082\u3057\u30e1\u30bd\u30c3\u30c9\u304c\u30ac\u30e9\u30b9\u30a8\u30f3\u30d7\u30c6\u30a3\u3092\u6307\u5b9a\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001SilcoSmooth\u51e6\u7406\u3057\u305f\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\u306f\u512a\u308c\u305f\u4ee3\u66ff\u624b\u6bb5\u3068\u306a\u308a\u5f97\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2684],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-44994","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-packed-micropacked-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2684,"label":"FAQ: Packed &amp; Micropacked Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":293,"filter":"raw","cat_ID":804,"category_count":293,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2684,"name":"FAQ: Packed &amp; Micropacked Columns","slug":"faq-packed-micropacked-columns","term_group":0,"term_taxonomy_id":2684,"taxonomy":"post_tag","description":"Browse frequently asked questions for packed and micropacked columns.","parent":0,"count":14,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=44994"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44994\/revisions"}],"predecessor-version":[{"id":72665,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/44994\/revisions\/72665"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=44994"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=44994"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=44994"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=44994"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=44994"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=44994"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=44994"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=44994"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=44994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}