{"id":45001,"date":"2025-07-30T21:28:09","date_gmt":"2025-07-30T21:28:09","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=45001"},"modified":"2025-12-09T15:52:13","modified_gmt":"2025-12-09T15:52:13","slug":"how-do-i-install-a-packed-column-into-a-capillary-gc-injection-port-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5131-ja\/how-do-i-install-a-packed-column-into-a-capillary-gc-injection-port-jp","title":{"rendered":"\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u6ce8\u5165\u53e3\u306b\u53d6\u308a\u4ed8\u3051\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3088\u3044\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306e\u6ce8\u5165\u53e3\u306b\u53d6\u308a\u4ed8\u3051\u308b\u6700\u3082\u7c21\u5358\u306a\u65b9\u6cd5\u306f\u3001\u300c\u30d4\u30b0\u30c6\u30fc\u30eb\u300d\u3092\u30bb\u30c3\u30c8\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u5fc5\u8981\u306a\u3082\u306e\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u305f\u5185\u5f840.53 mm\u306eMXT\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\uff08 (<a href=\"https:\/\/www.restek.com\/p\/70045\" target=\"_blank\" rel=\"noopener\">cat.# 70045<\/a>)\u3092\u30ab\u30c3\u30c8\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd \uff09\u3001\u9069\u5207\u306a\u5727\u7e2e\u30e6\u30cb\u30aa\u30f3\uff08\u30ec\u30c7\u30e5\u30fc\u30b7\u30f3\u30b0\u307e\u305f\u306f\u30b9\u30c8\u30ec\u30fc\u30c8\u30b9\u30eb\u30fc\uff09\u304a\u3088\u3073\u9069\u5207\u306a\u30d5\u30a7\u30e9\u30eb\u3060\u3051\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u5916\u5f841\/8\u30a4\u30f3\u30c1\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u5834\u5408\u3001\u30ec\u30c7\u30e5\u30fc\u30b7\u30f3\u30b0\u30e6\u30cb\u30aa\u30f3\u00a0<a href=\"https:\/\/www.restek.com\/p\/70045\" target=\"_blank\" rel=\"noopener\">cat.#\u00a0<\/a><a href=\"https:\/\/www.restek.com\/p\/23168\" target=\"_blank\" rel=\"noopener\">23168<\/a>\u00a0\u3068\u30d5\u30a7\u30e9\u30eb\u00a0<a href=\"https:\/\/www.restek.com\/p\/70045\" target=\"_blank\" rel=\"noopener\">cat.#\u00a0<\/a><a href=\"https:\/\/www.restek.com\/p\/20202\" target=\"_blank\" rel=\"noopener\">20202<\/a>\u00a0\uff08\u5185\u5f840.53 mm\u306eMXT\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u306e\u5834\u5408\uff09\u304c\u5fc5\u8981\u3067\u3059\u3002\u540c\u3058\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306f\u3001\u901a\u5e38\u3001\u691c\u51fa\u5668\u5074\u306b\u3082\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNOT3396-01-1024x696.jpg\" alt=\"&quot;pigtail&quot; set-up of guard column tubing, union and ferrules\" class=\"wp-image-3096\" title=\"-\"><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306e\u6ce8\u5165\u53e3\u306b\u53d6\u308a\u4ed8\u3051\u308b\u6700\u3082\u7c21\u5358\u306a\u65b9\u6cd5\u306f\u3001\u300c\u30d4\u30b0\u30c6\u30fc\u30eb\u300d\u3092\u30bb\u30c3\u30c8\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u5fc5\u8981\u306a\u3082\u306e\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u305f\u5185\u5f840.53 mm\u306eMXT\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\uff08 (cat.# 70045)\u3092\u30ab\u30c3\u30c8\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd \uff09\u3001\u9069\u5207\u306a\u5727\u7e2e\u30e6\u30cb\u30aa\u30f3\uff08\u30ec\u30c7\u30e5\u30fc\u30b7\u30f3\u30b0\u307e\u305f\u306f\u30b9\u30c8\u30ec\u30fc\u30c8\u30b9\u30eb\u30fc\uff09\u304a\u3088\u3073\u9069\u5207\u306a\u30d5\u30a7\u30e9\u30eb\u3060\u3051\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u5916\u5f841\/8\u30a4\u30f3\u30c1\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u5834\u5408\u3001\u30ec\u30c7\u30e5\u30fc\u30b7\u30f3\u30b0\u30e6\u30cb\u30aa\u30f3\u00a0cat.#\u00a023168\u00a0\u3068\u30d5\u30a7\u30e9\u30eb\u00a0cat.#\u00a020202\u00a0\uff08\u5185\u5f840.53 mm\u306eMXT\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u306e\u5834\u5408\uff09\u304c\u5fc5\u8981\u3067\u3059\u3002\u540c\u3058\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306f\u3001\u901a\u5e38\u3001\u691c\u51fa\u5668\u5074\u306b\u3082\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2684],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-45001","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-packed-micropacked-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2684,"label":"FAQ: Packed &amp; Micropacked Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2684,"name":"FAQ: Packed &amp; Micropacked Columns","slug":"faq-packed-micropacked-columns","term_group":0,"term_taxonomy_id":2684,"taxonomy":"post_tag","description":"Browse frequently asked questions for packed and micropacked columns.","parent":0,"count":14,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45001","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45001"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45001\/revisions"}],"predecessor-version":[{"id":72649,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45001\/revisions\/72649"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45001"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45001"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45001"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45001"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45001"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45001"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45001"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45001"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45001"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}