{"id":45004,"date":"2025-07-30T21:30:49","date_gmt":"2025-07-30T21:30:49","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=45004"},"modified":"2026-02-05T21:37:09","modified_gmt":"2026-02-05T21:37:09","slug":"convert-packed-column-injector-to-accept-fused-silica-capillary-columns-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5132-ja\/convert-packed-column-injector-to-accept-fused-silica-capillary-columns-jp","title":{"rendered":"\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u7528\u306e\u6ce8\u5165\u53e3\u3092\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u5909\u63db\u3059\u308b\u306b\u306f\u3069\u3046\u3059\u308c\u3070\u3044\u3044\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">1\/4\u201d\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u3092\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u306b\u5909\u63db\u3059\u308b\u306b\u306f\u3001Vu-Tight liner\u3068\u30b9\u30ea\u30fc\u30d6\u30a2\u30c0\u30d7\u30bf\u30fc\u3092\u5099\u3048\u305fUniliner\u30e9\u30a4\u30ca\u30fc\u306e2\u7a2e\u985e\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u5909\u63db\u30ad\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002Vu-Tight\u30e9\u30a4\u30ca\u30fc\u306f\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3001\u30ab\u30e9\u30e0\u3068\u30e9\u30a4\u30ca\u30fc\u306e\u63a5\u7d9a\u3092\u8996\u899a\u7684\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002Uniliner\u30e9\u30a4\u30ca\u30fc\u3068\u30b9\u30ea\u30fc\u30d6\u30a2\u30c0\u30d7\u30bf\u30fc\u306f\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u969b\u306b\u30c0\u30a4\u30ec\u30af\u30c8\u307e\u305f\u306f\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u306e\u3044\u305a\u308c\u304b\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u4e21\u65b9\u306e\u30b7\u30b9\u30c6\u30e0\u306f\u30e9\u30a4\u30ca\u30fc\u3068\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u306e\u9593\u306bPress-Tight\u63a5\u7d9a\u3092\u7d44\u307f\u8fbc\u307f\u3001\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u6eb6\u5a92\u30d4\u30fc\u30af\u306e\u30c6\u30a4\u30ea\u30f3\u30b0\u3092\u8efd\u6e1b\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u8a73\u7d30\u306a\u8aac\u660e\u3068\u88c5\u7f6e\u306e\u4e92\u63db\u6027\u306e\u60c5\u5831\u306f\u5f0a\u793e\u306e\u30ab\u30bf\u30ed\u30b0\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>1\/4\u201d\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u3092\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u306b\u5909\u63db\u3059\u308b\u306b\u306f\u3001Vu-Tight liner\u3068\u30b9\u30ea\u30fc\u30d6\u30a2\u30c0\u30d7\u30bf\u30fc\u3092\u5099\u3048\u305fUniliner\u30e9\u30a4\u30ca\u30fc\u306e2\u7a2e\u985e\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u5909\u63db\u30ad\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002Vu-Tight\u30e9\u30a4\u30ca\u30fc\u306f\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3001\u30ab\u30e9\u30e0\u3068\u30e9\u30a4\u30ca\u30fc\u306e\u63a5\u7d9a\u3092\u8996\u899a\u7684\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002Uniliner\u30e9\u30a4\u30ca\u30fc\u3068\u30b9\u30ea\u30fc\u30d6\u30a2\u30c0\u30d7\u30bf\u30fc\u306f\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u969b\u306b\u30c0\u30a4\u30ec\u30af\u30c8\u307e\u305f\u306f\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u306e\u3044\u305a\u308c\u304b\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u4e21\u65b9\u306e\u30b7\u30b9\u30c6\u30e0\u306f\u30e9\u30a4\u30ca\u30fc\u3068\u30ab\u30e9\u30e0\u30a4\u30f3\u30ec\u30c3\u30c8\u306e\u9593\u306bPress-Tight\u63a5\u7d9a\u3092\u7d44\u307f\u8fbc\u307f\u3001\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u6eb6\u5a92\u30d4\u30fc\u30af\u306e\u30c6\u30a4\u30ea\u30f3\u30b0\u3092\u8efd\u6e1b\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u8a73\u7d30\u306a\u8aac\u660e\u3068\u88c5\u7f6e\u306e\u4e92\u63db\u6027\u306e\u60c5\u5831\u306f\u5f0a\u793e\u306e\u30ab\u30bf\u30ed\u30b0\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2684],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-45004","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-packed-micropacked-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2684,"label":"FAQ: Packed &amp; Micropacked Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":804,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2684,"name":"FAQ: Packed &amp; Micropacked Columns","slug":"faq-packed-micropacked-columns","term_group":0,"term_taxonomy_id":2684,"taxonomy":"post_tag","description":"Browse frequently asked questions for packed and micropacked columns.","parent":0,"count":14,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45004"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45004\/revisions"}],"predecessor-version":[{"id":87113,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45004\/revisions\/87113"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45004"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45004"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45004"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45004"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45004"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45004"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45004"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45004"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}