{"id":45011,"date":"2025-07-30T21:47:18","date_gmt":"2025-07-30T21:47:18","guid":{"rendered":"https:\/\/live-discover-restek.pantheonsite.io\/?p=45011"},"modified":"2025-12-09T16:06:03","modified_gmt":"2025-12-09T16:06:03","slug":"how-do-i-condition-a-new-packed-or-micropacked-column-jp","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/faq-ja\/gnot5134-ja\/how-do-i-condition-a-new-packed-or-micropacked-column-jp","title":{"rendered":"\u65b0\u3057\u3044\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306f\u3069\u3046\u3059\u308c\u3070\u3044\u3044\u3067\u3059\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306e\u624b\u9806\u306b\u5f93\u3044\u3001\u65b0\u3057\u3044\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3001\u307e\u305f\u306f\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u53d6\u308a\u4ed8\u3051\u304b\u3089\u6570\u6642\u9593\u5f8c\u306b\u3059\u3050\u306b\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3059\u308b\u969b\u306f\u3001\u5fc5\u305a<strong>\u4e7e\u71e5\u3057\u305f\uff08\u6c34\u5206\u3092\u542b\u307e\u306a\u3044\uff09\u306e\u9ad8\u7d14\u5ea6\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/strong>\u306e\u307f\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u54c1\u8cea\u306e\u826f\u3044\u30ac\u30b9\u30c8\u30e9\u30c3\u30d7\u306e\u4f7f\u7528\u3092<strong>\u5f37\u304f<\/strong>\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ol style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>GC\u5185\u306e\u3059\u3079\u3066\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374\u3057\u3001\u305d\u306e\u5f8c\u3059\u3079\u3066\u306eGC\u30ac\u30b9\u3092\u6b62\u3081\u307e\u3059\u3002\u30ab\u30e9\u30e0\u304c\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u3068\u88c5\u7f6e\u304c\u6e1b\u5727\u3055\u308c\u308b\u306e\u3092\u5f85\u3063\u3066\u304b\u3089\u4f5c\u696d\u3092\u9032\u3081\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>I<strong>\u6ce8\u610f:<\/strong>\u00a0\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092GC\uff08\u7279\u306b\u30a4\u30f3\u30ec\u30c3\u30c8\uff09\u304b\u3089\u53d6\u308a\u5916\u3059\u524d\u306b\u6e1b\u5727\u3055\u305b\u306a\u3044\u3068\u3001\u30b5\u30fc\u30b8\u5727\u529b\u304c\u767a\u751f\u3057\u3001\u30ab\u30e9\u30e0\u304b\u3089\u5145\u586b\u5264\u304c\u6d41\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002GC\u5185\u306e\u3059\u3079\u3066\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u304c\u51b7\u5374\u3055\u308c\u308b\u524d\u306b\u6e1b\u5727\u3059\u308b\u3068\u3001\u30ab\u30e9\u30e0\u304c\u640d\u50b7\u3059\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u65b0\u3057\u3044\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u307e\u305f\u306f\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u6ce8\u5165\u53e3\u306b\u53d6\u308a\u4ed8\u3051\u307e\u3059\u3002 \u3053\u306e\u6642\u70b9\u3067\u306f\u30ab\u30e9\u30e0\u3092\u691c\u51fa\u5668\u306b<strong>\u63a5\u7d9a\u305b\u305a<\/strong>\u3001\u4ee3\u308f\u308a\u306b\u691c\u51fa\u5668\u3092\u30ad\u30e3\u30c3\u30d7\u3057\u307e\u3059\u3002\u52a0\u71b1\u30be\u30fc\u30f3\u306f<strong>\u30aa\u30f3\u306b\u3057\u306a\u3044\u3067<\/strong>\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u308c\u304c\u30ab\u30e9\u30e0\u304b\u3089\u51fa\u59cb\u3081\u308b\u307e\u3067\u3001\u30d8\u30c3\u30c9\u5727\u3092\u3086\u3063\u304f\u308a\u5897\u52a0\u3055\u305b\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6ce8\u610f\u4e8b\u9805:<\/strong>\u00a0\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u6c34\u7d20\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u6c34\u7d20\u306e\u84c4\u7a4d\u3092\u9632\u3050\u305f\u3081\u306b\u30ab\u30e9\u30e0\u306e\u958b\u653e\u7aef\u3092\u30aa\u30fc\u30d6\u30f3\u304b\u3089\u5b89\u5168\u306b\u6392\u6c17\u3059\u308b\u304b\u3001\u975e\u7834\u58ca\u578b\u306e\u691c\u51fa\u5668\uff08TCD\u306a\u3069\uff09\u304b\u3089\u6c34\u7d20\u30ac\u30b9\u3092\u5b89\u5168\u306b\u6392\u6c17\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u7206\u767a\u306e\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u3067\u3059\u3002FID \u306a\u3069\u306e\u7834\u58ca\u578b\u306e\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u708e\u304c\u70b9\u706b\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<em><strong>\u6ce8: \u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u3092\u3001\u70b9\u706f\u3057\u3066\u3044\u308b FID \u307e\u305f\u306f\u52a0\u71b1\u3055\u308c\u305f\u691c\u51fa\u5668\u306b\u6c7a\u3057\u3066\u63a5\u7d9a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<\/strong><\/em><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong><strong>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba<\/strong><\/strong><\/td><td><strong><strong>\u6d41\u91cf<\/strong><\/strong><\/td><\/tr><tr><td>0.53 mm ID (0.74 mm OD)<\/td><td>5 mL\/min<\/td><\/tr><tr><td>0.75 mm ID (0.95 mm OD)<\/td><td>7.5 mL\/min<\/td><\/tr><tr><td>1 mm ID (1\/16\u201d OD)<\/td><td>10 mL\/min<\/td><\/tr><tr><td>2 mm ID (1\/8\u201d OD)<\/td><td>20 mL\/min<\/td><\/tr><tr><td>3.1 mm ID (3\/16\u201d OD)<\/td><td>30 mL\/min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong><br><\/strong><\/em><strong>Table I:<\/strong>\u00a0\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u304a\u3088\u3073\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u4e00\u822c\u7684\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf<\/p>\n\n\n\n<ol start=\"5\" style=\"list-style-type:lower-alpha\" class=\"wp-block-list\">\n<li>\u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u3092\u53d6\u308a\u5916\u3057\u3001\u3055\u3089\u306b10\u5206\u9593\u30ab\u30e9\u30e0\u3092\u30d1\u30fc\u30b8\u3057\u3066\u3059\u3079\u3066\u306e\u7a7a\u6c17\u3092\u53d6\u308a\u9664\u304d\u307e\u3059\u3002GC\u30aa\u30fc\u30d6\u30f3\u306e\u6e29\u5ea6\u3092100\u00b0C\u306b\u8a2d\u5b9a\u3057\u307e\u3059\u3002GC\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\uff08\u8a72\u5f53\u3059\u308b\u5834\u5408\uff09\u3092\u6240\u5b9a\u306e\u6e29\u5ea6\u307e\u3067\u52a0\u71b1\u3057\u307e\u3059\u304c\u3001<strong>\u30ab\u30e9\u30e0\u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u308b\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u3092\u8d85\u3048\u308b\u6e29\u5ea6\u306b\u306f\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044<\/strong>\u3002\u30aa\u30fc\u30d6\u30f3\u30925\u00b0C\/min\u3067\u6607\u6e29\u3057\u3001\u30ab\u30e9\u30e0\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u304b\u308920\u00b0C\u4f4e\u3044\u6e29\u5ea6\u307e\u3067\u6607\u6e29\u3059\u308b\u3088\u3046\u306b\u30d7\u30ed\u30b0\u30e9\u30e0\u3057\u3001GC\u30aa\u30fc\u30d6\u30f3\u306e\u52a0\u71b1\u3092\u59cb\u3081\u307e\u3059\u3002\u9069\u5207\u306a\u6e29\u5ea6\u306b\u9054\u3057\u305f\u3089\uff08\u30ab\u30e9\u30e0\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u304b\u308920\u00b0C\u4f4e\u3044\u6e29\u5ea6\uff09\u3001\u3053\u306e\u6e29\u5ea6\u30921\u6642\u9593\u4fdd\u6301\u3057\u307e\u3059\uff08\u4ee5\u4e0b\u306b\u30ea\u30b9\u30c8\u3055\u308c\u3066\u3044\u308b\u5145\u586b\u5264\u3092\u9664\u304f\uff09\u3002<br><br><em>\u6db2\u76f8\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c10%\u3092\u8d85\u3048\u308b\u56fa\u76f8\u62c5\u4f53\u306e\u5834\u5408:<\/em>\u00a02\u6642\u9593\u4fdd\u6301<br><em>\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u306e\u5834\u5408:<\/em>\u00a03\u6642\u9593\u4fdd\u6301\uff08\u9ad8\u7d14\u5ea6\u306e\u4e7e\u71e5\u7a92\u7d20\u3067\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3082\u63a8\u5968\u3057\u307e\u3059\u3002\uff09<br><\/li>\n\n\n\n<li>\u3053\u3053\u307e\u3067\u306e\u5de5\u7a0b\u3067\u30ab\u30e9\u30e0\u306f\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3055\u308c\u3001\u3059\u3050\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u5f79\u7acb\u3064\u30d2\u30f3\u30c8:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4ee5\u4e0b\u306e\u4f5c\u696d\u3092\u305b\u305a\u306bGC\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\uff08\u305f\u3068\u3048\u3001\u30bb\u30d7\u30bf\u30e0\u3084\u30e9\u30a4\u30ca\u30fc\u306e\u4ea4\u63db\u3067\u3082\uff09\u304a\u3088\u3073\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3084\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092GC\u304b\u3089\u5916\u3059\u3053\u3068\u3092\u7d76\u5bfe\u306b\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<br><strong>A\uff09<\/strong>GC\u306e\u3059\u3079\u3066\u306e\u52a0\u71b1\u30be\u30fc\u30f3\u3092\u51b7\u5374\u3059\u308b<br><strong>B\uff09<\/strong>\u3059\u3079\u3066\u306eGC\u30ac\u30b9\u3092\u30aa\u30d5\u306b\u3059\u308b<br><strong>C\uff09<\/strong>\u30ab\u30e9\u30e0\u3068\u6a5f\u5668\u306e\u4e21\u65b9\u3092\u6e1b\u5727\u3059\u308b<br>\u3053\u308c\u3089\u306e\u4f5c\u696d\u3092\u5b9f\u884c\u3057\u3066\u3044\u306a\u3044\u3068\u3001\u30ab\u30e9\u30e0\u306e\u5145\u586b\u5c64\u304c\u5d29\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u30ab\u30e9\u30e0\u304b\u3089\u7c92\u5b50\u304c\u6d41\u51fa\u3057\u305f\u308a\u3001\u3042\u308b\u3044\u306f\u30ab\u30e9\u30e0\u304c\u640d\u50b7\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u30921\u9031\u9593\u4ee5\u4e0a\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u3092\u51b7\u5374\u3057\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3092\u30aa\u30d5\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3092\u30aa\u30f3\u306e\u307e\u307e\u306b\u3059\u308b\u5834\u5408\u306f\u3001\u30aa\u30fc\u30d6\u30f3\u3092100\u00b0C\u306b\u8a2d\u5b9a\u3057\u3066\u3001\u30ab\u30e9\u30e0\u5185\u306e\u6e7f\u6c17\uff08\u6c34\uff09\u304c\u51dd\u7e2e\u3059\u308b\u306e\u3092\u9632\u304e\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\uff08\u5185\u5f840.53mm \u304b\u3089\u5185\u5f841mm \uff09\u306f\u3001HID\u3001DID\u3001FID\u306a\u3069\u306e\u9ad8\u611f\u5ea6\u691c\u51fa\u5668\u3068\u76f8\u6027\u304c\u826f\u3044\u3067\u3059\u3002\u305f\u3060\u3057\u3001TCD\u306e\u3088\u3046\u306a\u4f4e\u611f\u5ea6\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u3088\u308a\u9ad8\u3044\u8ca0\u8377\u5bb9\u91cf\u306e\u305f\u3081\u306b\u5185\u5f842mm\uff08\u5916\u5f841\/8\u201d\uff09\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u691c\u8a0e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\u4ee5\u4e0b\u306e\u624b\u9806\u306b\u5f93\u3044\u3001\u65b0\u3057\u3044\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3001\u307e\u305f\u306f\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u53d6\u308a\u4ed8\u3051\u304b\u3089\u6570\u6642\u9593\u5f8c\u306b\u3059\u3050\u306b\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3059\u308b\u969b\u306f\u3001\u5fc5\u305a\u4e7e\u71e5\u3057\u305f\uff08\u6c34\u5206\u3092\u542b\u307e\u306a\u3044\uff09\u306e\u9ad8\u7d14\u5ea6\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u307f\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u54c1\u8cea\u306e\u826f\u3044\u30ac\u30b9\u30c8\u30e9\u30c3\u30d7\u306e\u4f7f\u7528\u3092\u5f37\u304f\u304a\u52e7\u3081\u3057\u307e\u3059\u3002 \u6ce8\u610f\u4e8b\u9805:\u00a0\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u6c34\u7d20\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u6c34\u7d20\u306e\u84c4\u7a4d\u3092\u9632\u3050\u305f\u3081\u306b\u30ab\u30e9\u30e0\u306e\u958b\u653e\u7aef\u3092\u30aa\u30fc\u30d6\u30f3\u304b\u3089\u5b89\u5168\u306b\u6392\u6c17\u3059\u308b\u304b\u3001\u975e\u7834\u58ca\u578b\u306e\u691c\u51fa\u5668\uff08TCD\u306a\u3069\uff09\u304b\u3089\u6c34\u7d20\u30ac\u30b9\u3092\u5b89\u5168\u306b\u6392\u6c17\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u7206\u767a\u306e\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u3067\u3059\u3002FID \u306a\u3069\u306e\u7834\u58ca\u578b\u306e\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u708e\u304c\u70b9\u706b\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u6ce8: \u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u3092\u3001\u70b9\u706f\u3057\u3066\u3044\u308b FID \u307e\u305f\u306f\u52a0\u71b1\u3055\u308c\u305f\u691c\u51fa\u5668\u306b\u6c7a\u3057\u3066\u63a5\u7d9a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002 \u30ab\u30e9\u30e0\u30b5\u30a4\u30ba \u6d41\u91cf 0.53 mm ID (0.74 mm OD) 5 mL\/min 0.75 mm ID (0.95 mm OD) 7.5 mL\/min 1 mm ID (1\/16\u201d OD) 10 mL\/min 2 mm ID (1\/8\u201d OD) 20 mL\/min 3.1 mm ID (3\/16\u201d OD) 30 mL\/min Table I:\u00a0\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u304a\u3088\u3073\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u4e00\u822c\u7684\u306a\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf \u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u306e\u5f79\u7acb\u3064\u30d2\u30f3\u30c8:<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[804],"tags":[2684],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-45011","post","type-post","status-publish","format-standard","hentry","category-faq-ja","tag-faq-packed-micropacked-columns"],"acf":[],"taxonomy_info":{"category":[{"value":804,"label":"FAQ"}],"post_tag":[{"value":2684,"label":"FAQ: Packed &amp; Micropacked Columns"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":804,"name":"FAQ","slug":"faq-ja","term_group":0,"term_taxonomy_id":804,"taxonomy":"category","description":"","parent":0,"count":293,"filter":"raw","cat_ID":804,"category_count":293,"category_description":"","cat_name":"FAQ","category_nicename":"faq-ja","category_parent":0}],"tag_info":[{"term_id":2684,"name":"FAQ: Packed &amp; Micropacked Columns","slug":"faq-packed-micropacked-columns","term_group":0,"term_taxonomy_id":2684,"taxonomy":"post_tag","description":"Browse frequently asked questions for packed and micropacked columns.","parent":0,"count":14,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45011","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45011"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45011\/revisions"}],"predecessor-version":[{"id":72694,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45011\/revisions\/72694"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45011"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45011"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45011"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45011"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45011"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45011"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45011"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45011"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45011"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}