{"id":45321,"date":"2021-01-28T13:30:00","date_gmt":"2021-01-28T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japan-guide-to-gc-column-selection-and-optimizing-separations\/"},"modified":"2026-04-07T01:33:34","modified_gmt":"2026-04-07T01:33:34","slug":"japan-guide-to-gc-column-selection-and-optimizing-separations","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar1724-ja\/japan-guide-to-gc-column-selection-and-optimizing-separations","title":{"rendered":"GC\u30ab\u30e9\u30e0\u9078\u629e\u3068\u5206\u96e2\u306e\u6700\u9069\u5316\u30ac\u30a4\u30c9"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6b63\u3057\u3044GC\u30ab\u30e9\u30e0\u3092\u9078\u3076\u65b9\u6cd5\u3092\u5b66\u3076\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u5206\u96e2\u3068\u901f\u5ea6\u306e\u30d9\u30b9\u30c8\u30d0\u30e9\u30f3\u30b9\u306e\u305f\u3081\u306b\u6700\u9069\u5316\u3092\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/li>\n\n\n\n<li><strong>\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u75c7\u72b6\u306b\u57fa\u3065\u3044\u3066\u8fc5\u901f\u304b\u3064\u52b9\u679c\u7684\u306b\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u6642\u9593\u3068\u5206\u96e2\u5ea6\u306e\u6700\u9069\u5316\u306f\u3001\u30e9\u30dc\u306e\u751f\u7523\u6027\u5411\u4e0a\u306b\u76f4\u7d50\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u306b\u306f\u3001\u5206\u96e2\u5ea6\u306e\u65b9\u7a0b\u5f0f\uff08<strong>Figure 1<\/strong>\uff09\u3092\u7a4d\u6975\u7684\u306b\u6d3b\u7528\u3057\u3001\u5206\u96e2\u5ea6\u3092\u5b9a\u91cf\u7684\u306b\u5236\u5fa1\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u5206\u96e2\u5ea6\u306e\u65b9\u7a0b\u5f0f\u306f\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u3001\u30ab\u30e9\u30e0\u9577\u3001\u5185\u5f84\uff08ID\uff09\u3001\u304a\u3088\u3073\u819c\u539a\u3092\u9078\u629e\u3059\u308b\u969b\u306e\u6307\u91dd\u3068\u306a\u308a\u307e\u3059\u3002GC\u30ab\u30e9\u30e0\u306e\u7269\u7406\u7684\u7279\u6027\u3068\u5206\u96e2\u5ea6\u306e\u95a2\u4fc2\u6027\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u96e2\u52b9\u7387\u3068\u5206\u6790\u901f\u5ea6\u306e\u4e21\u9762\u304b\u3089\u6700\u9069\u5316\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u8a18\u4e8b\u306fGC\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\u3068\u3057\u3066\u3001\u307e\u305a\u5206\u96e2\u306e\u57fa\u672c\u306b\u7740\u76ee\u3057\u3001\u6700\u9069\u306aGC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u8003\u3048\u65b9\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u96e2\u5411\u4e0a\u306e\u672c\u8cea\u3068\u6700\u9069\u6761\u4ef6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306b\u3068\u3063\u3066\u3001\u5206\u96e2\u304c\u5341\u5206\u304b\u3069\u3046\u304b\u306f\u6700\u5927\u306e\u95a2\u5fc3\u4e8b\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u300c\u5341\u5206\u306a\u5206\u96e2\u300d\u3068\u306f\u3001\u5fc5\u305a\u3057\u3082\u6700\u5927\u9650\u306e\u5206\u96e2\u3092\u610f\u5473\u3057\u307e\u305b\u3093\u3002\u5b9f\u969b\u306f\u30011) \u30b7\u30e3\u30fc\u30d7\u3067\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u304c\u5f97\u3089\u308c\u308b\u30012) \u4e0d\u8981\u306b\u4fdd\u6301\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af\u304c\u5e83\u304c\u308b\u3053\u3068\u3092\u907f\u3051\u308b\u3001\u3068\u3044\u3046\u6761\u4ef6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5206\u96e2\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001\u300c\u5b8c\u74a7\u306a\u5206\u96e2\uff08\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\uff09\u300d\u306b\u5f71\u97ff\u3059\u308b\u30ab\u30e9\u30e0\u56e0\u5b50\u3068\u975e\u30ab\u30e9\u30e0\u56e0\u5b50\u3092\u7dcf\u5408\u7684\u306b\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3067\u3057\u3087\u3046\u3002\u305d\u308c\u3092\u8e0f\u307e\u3048\u3066\u521d\u3081\u3066\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u3068\u5206\u96e2\u30fb\u5206\u6790\u6642\u9593\u306e\u6700\u9069\u5316\u306b\u53d6\u308a\u7d44\u3081\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/diagram-article-GNAR1724A-01.jpg\" alt=\"select the right column and optimize your separation\" title=\"-\"><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u5206\u96e2\u5ea6\u306e\u65b9\u7a0b\u5f0f\u3068\u305d\u308c\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u4fc2\u6570<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"387\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01-1024x387.png\" alt=\"\" class=\"wp-image-29967\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01-1024x387.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01-300x114.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01-768x291.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01-1536x581.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-1-figure-article-GNAR1724B-01.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u6700\u9069\u306aGC\u30ab\u30e9\u30e0\u306e\u9078\u629e\u30ac\u30a4\u30c9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3010B\u3011\u306b\u3064\u3044\u3066\u8a73\u7d30\u306b\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u3010B\u3011\u306e\u9805\u76ee4\uff0e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30c8\u30e9\u30d6\u30eb\u3078\u306e\u5bfe\u51e6\u65b9\u6cd5\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u3061\u3089\u3082\u305c\u3072\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>\u3010A\u3011\u7c21\u6613\u7684\u306a\u9078\u629e\u624b\u9806<\/strong><\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u307e\u305a\u6700\u521d\u306b<strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u56fa\u6709\u306e\u56fa\u5b9a\u76f8<\/strong>\u3092\u63a2\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306e\u30ab\u30e9\u30e0\u306f\u7279\u5b9a\u306e\u5206\u6790\u306b\u6700\u9069\u5316\u3055\u308c\u3066\u304a\u308a\u3001\u6700\u77ed\u6642\u9593\u3067\u6700\u9ad8\u306e\u5206\u89e3\u5ea6\u3092\u63d0\u4f9b\u3057\u307e\u3059\uff08<strong>Table III<\/strong>\uff09\u3002<\/li>\n\n\n\n<li>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u56fa\u6709\u306e\u30ab\u30e9\u30e0\u304c\u5229\u7528\u3067\u304d\u306a\u3044\u5834\u5408\u3001\u4f4e\u6fc3\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u307e\u305f\u306f\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001<strong>Rxi\u30ab\u30e9\u30e0<\/strong>\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\u3002Rxi\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306f\u3001\u512a\u308c\u305f\u4e0d\u6d3b\u6027\u5ea6\u3001\u4f4e\u30d6\u30ea\u30fc\u30c9\u3001\u9ad8\u3044\u518d\u73fe\u6027\u3092\u63d0\u4f9b\u3057\u3001\u5fae\u91cf\u5206\u6790\u3068MS\u5206\u6790\u306b\u7406\u60f3\u7684\u306a\u9ad8\u6027\u80fd\u306eGC\u30ab\u30e9\u30e0\u3092\u63d0\u4f9b\u3057\u307e\u3059\uff08<strong>Table II<\/strong>\uff09\u3002<\/li>\n\n\n\n<li>\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u5834\u5408\u306b\u306f\u3001\u6c4e\u7528\u306e<strong>Rtx\u30ab\u30e9\u30e0<\/strong>\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\uff08<strong>Table II<\/strong>\uff09\u3002<\/li>\n<\/ol>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"section_contents\"><strong>\u3010B\u3011\u4e3b\u8981\u30d1\u30e9\u30e1\u30fc\u30bf\uff08\u4fc2\u6570\uff09\u306b\u57fa\u3065\u3044\u305f\u9078\u629e\u624b\u9806<\/strong><\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u3000<a href=\"#sec1\">\u5206\u96e2\u4fc2\u6570\uff08\u03b1\uff09\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u306a\u56fa\u5b9a\u76f8\u306e\u9078\u629e<\/a><\/li>\n\n\n\n<li>\u3000<a href=\"#sec2\">\u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u306b\u57fa\u3065\u3044\u305f\u30ab\u30e9\u30e0\u306e\u819c\u539a\u3068\u5185\u5f84\u306e\u9078\u629e<\/a><\/li>\n\n\n\n<li>\u3000<a href=\"#sec3\">\u7406\u8ad6\u6bb5\u6570\uff08N\u3001\u52b9\u7387\uff09\u3092\u8003\u616e\u3057\u305f\u30ab\u30e9\u30e0\u9577\u3001\u5185\u5f84\u3001\u304a\u3088\u3073\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e<\/a><\/li>\n\n\n\n<li>\u3000<a href=\"#sec4\">\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u30d2\u30f3\u30c8<\/a><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec1\">1. \u5206\u96e2\u4fc2\u6570\uff08\u03b1\uff09\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u306a\u56fa\u5b9a\u76f8\u306e\u9078\u629e<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"69\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01-1024x69.jpg\" alt=\"\" class=\"wp-image-18333\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01-1024x69.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01-300x20.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01-768x52.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01-1536x104.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306f\u3001GC\u5206\u96e2\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306e\u7b2c\u4e00\u6b69\u3067\u3059\u3002\u5206\u96e2\u4fc2\u6570\uff08\u03b1\uff09\u306f\u3001\u5206\u96e2\u80fd\u306b\u6700\u3082\u5927\u304d\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3057\u3001\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u3068\u9078\u629e\u6027\u306b\u5f37\u304f\u5f71\u97ff\u3055\u308c\u308b\u305f\u3081\u3001\u3053\u308c\u306f\u6700\u3082\u91cd\u8981\u306a\u6c7a\u5b9a\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u306f\u3001\u56fa\u5b9a\u76f8\u306e\u7a2e\u985e\u3068\u56fa\u5b9a\u76f8\u5185\u306e\u5b98\u80fd\u57fa\u306e\u91cf\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001\u56fa\u5b9a\u76f8\u3068\u5bfe\u8c61\u306e\u5206\u6790\u7a2e\u306e\u4e21\u65b9\u306e\u6975\u6027\u3092\u8003\u616e\u3057\u3066\u8a2d\u5b9a\u3092\u304a\u3053\u306a\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u56fa\u5b9a\u76f8\u3068\u5206\u6790\u7a2e\u306e\u6975\u6027\u304c\u985e\u4f3c\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u76f8\u4e92\u4f5c\u7528\u304c\u5f37\u304f\u306a\u308a\u3001\u3088\u308a\u5f37\u3044\u4fdd\u6301\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u4fdd\u6301\u304c\u5897\u3059\u3068\u3001\u901a\u5e38\u306f\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u306f\u3001\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u6709\u7528\u306a\u8003\u616e\u4e8b\u9805\u3067\u3042\u308a\u3001\u30ab\u30e9\u30e0\u9078\u629e\u6027\u3068\u5206\u96e2\u4fc2\u6570\u306b\u5f37\u304f\u5f71\u97ff\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IUPAC\u306b\u3088\u308c\u3070\u3001\u56fa\u5b9a\u76f8\u306e\u9078\u629e\u6027\u306f\u3001\u7279\u5b9a\u306e\u7269\u8cea\u306e\u6e2c\u5b9a\u306b\u4ed6\u306e\u7269\u8cea\u304c\u3069\u308c\u3060\u3051\u5e72\u6e09\u3059\u308b\u304b\u3068\u5b9a\u7fa9\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u9078\u629e\u6027\u306f\u3001\u56fa\u5b9a\u76f8\u306e\u7d44\u6210\u3068\u305d\u308c\u304c\u76ee\u6a19\u5316\u5408\u7269\u3068\u3069\u306e\u3088\u3046\u306b\u76f8\u4e92\u4f5c\u7528\uff08\u6c34\u7d20\u7d50\u5408\u3001\u5206\u6563\u3001\u53cc\u6975\u5b50-\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\u3001\u304a\u3088\u3073\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u9078\u629e\u6027\uff09\u3059\u308b\u304b\u306b\u76f4\u63a5\u3001\u95a2\u9023\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u4e2d\u306e\u30e1\u30c1\u30eb\u57fa\u304c\u30d5\u30a7\u30cb\u30eb\u3084\u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u57fa\u306a\u3069\u306e\u7570\u306a\u308b\u5b98\u80fd\u57fa\u306b\u7f6e\u304d\u63db\u3048\u3089\u308c\u308b\u3068\u3001\u305d\u308c\u3089\u306e\u5b98\u80fd\u57fa\u3068\u76f8\u6eb6\u6027\u306e\u3042\u308b\u5316\u5408\u7269\uff08\u4f8b\u3048\u3070\u3001\u82b3\u9999\u65cf\u5316\u5408\u7269\u3084\u6975\u6027\u5316\u5408\u7269\uff09\u306f\u3088\u308a\u5f37\u304f\u76f8\u4e92\u4f5c\u7528\u3057\u3001\u901a\u5e38\u306f\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3057\u3001\u9078\u629e\u6027\u304c\u5897\u52a0\u3057\u307e\u3059\u3002\u5225\u306e\u4f8b\u3068\u3057\u3066\u3001Rtx-200\u306e\u56fa\u5b9a\u76f8\u306f\u3001\u30d5\u30c3\u7d20\u306e\u5b98\u80fd\u57fa\u3092\u542b\u307f\u305f\u3081\u3001\u30cf\u30ed\u30b2\u30f3\u3001\u7a92\u7d20\u3001\u307e\u305f\u306f\u30ab\u30eb\u30dc\u30cb\u30eb\u57fa\u3092\u542b\u3080\u5206\u6790\u7269\u306b\u5bfe\u3057\u3066\u975e\u5e38\u306b\u9078\u629e\u7684\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9078\u629e\u6027\u306f\u65e2\u5b58\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u307e\u305f\u306f\u30ea\u30c6\u30f3\u30b7\u30e7\u30f3\u30a4\u30f3\u30c7\u30c3\u30af\u30b9\uff08\u4fdd\u6301\u6307\u6570\uff09\uff08<strong>Table I<\/strong>\uff09\u3092\u4f7f\u7528\u3057\u3066\u8fd1\u4f3c\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u3053\u308c\u3089\u306f\u7279\u5b9a\u306e\u5206\u6790\u306b\u6700\u9069\u306a\u56fa\u5b9a\u76f8\u306e\u6bd4\u8f03\u3001\u9078\u629e\u306e\u305f\u3081\u306e\u6709\u7528\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u3068\u9078\u629e\u6027\u306f\u3001\u5206\u96e2\u4fc2\u6570\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306f\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306e\u4e3b\u306a\u8003\u616e\u4e8b\u9805\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u6e29\u5ea6\u5236\u9650\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u6975\u6027\u306e\u9ad8\u3044\u56fa\u5b9a\u76f8\u306f\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u304c\u4f4e\u3044\u305f\u3081\u3001\u5206\u6790\u5bfe\u8c61\u306e\u7a2e\u985e\u306b\u5bfe\u3059\u308b\u6700\u9069\u306a\u6975\u6027\u3068\u9078\u629e\u6027\u306b\u5408\u308f\u305b\u3066\u3001\u9069\u5207\u306a\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u3092\u6301\u3064\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<strong>Table II<\/strong>\u3068<strong>Figure 2<\/strong>\u3092\u4f7f\u7528\u3057\u3066\u3001\u5206\u6790\u306e\u9078\u629e\u6027\u3001\u6975\u6027\u3001\u6e29\u5ea6\u8981\u4ef6\u3092\u8003\u616e\u3057\u305f\u3046\u3048\u3067\u3001\u3069\u306e\u30ab\u30e9\u30e0\u304c\u6700\u3082\u9069\u3057\u3066\u3044\u308b\u304b\u3092\u5224\u65ad\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u7279\u5b9a\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u5411\u3051\u306b\u8a2d\u8a08\u3055\u308c\u305f\u7279\u6b8a\u306a\u56fa\u5b9a\u76f8\u306e\u4e00\u89a7\u306f\u3001<strong>Table III<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u304f\u306e\u5834\u5408\u3001GC\u306e\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u7570\u306a\u308b\u3068\u3001\u540c\u3058\u30ab\u30e9\u30e0\u3067\u3082\u30b5\u30f3\u30d7\u30eb\u306e\u6eb6\u51fa\u9806\u5e8f\u304c\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u5909\u66f4\u3059\u308b\u5834\u5408\u306f\u3001\u6eb6\u51fa\u9806\u5e8f\u3092\u518d\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> GC\u56fa\u5b9a\u76f8\u306eKovat\u306e\u4fdd\u6301\u6307\u6570\u306f\u3001\u9078\u629e\u6027\u3092\u8fd1\u4f3c\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u53ef\u80fd<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u56fa\u5b9a\u76f8<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30d9\u30f3\u30bc\u30f3<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30d6\u30bf\u30ce\u30fc\u30eb<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30da\u30f3\u30bf\u30ce\u30f3<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30cb\u30c8\u30ed\u30d7\u30ed\u30d1\u30f3<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">100% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">651<\/td><td class=\"has-text-align-center\" data-align=\"center\">651<\/td><td class=\"has-text-align-center\" data-align=\"center\">667<\/td><td class=\"has-text-align-center\" data-align=\"center\">705<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5% \u30b8\u30d5\u30a7\u30cb\u30eb\/95% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">667<\/td><td class=\"has-text-align-center\" data-align=\"center\">667<\/td><td class=\"has-text-align-center\" data-align=\"center\">689<\/td><td class=\"has-text-align-center\" data-align=\"center\">743<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">20% \u30b8\u30d5\u30a7\u30cb\u30eb\/80% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">711<\/td><td class=\"has-text-align-center\" data-align=\"center\">704<\/td><td class=\"has-text-align-center\" data-align=\"center\">740<\/td><td class=\"has-text-align-center\" data-align=\"center\">820<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\/94% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">689<\/td><td class=\"has-text-align-center\" data-align=\"center\">729<\/td><td class=\"has-text-align-center\" data-align=\"center\">739<\/td><td class=\"has-text-align-center\" data-align=\"center\">816<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">35% \u30b8\u30d5\u30a7\u30cb\u30eb\/65% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">746<\/td><td class=\"has-text-align-center\" data-align=\"center\">733<\/td><td class=\"has-text-align-center\" data-align=\"center\">773<\/td><td class=\"has-text-align-center\" data-align=\"center\">867<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">738<\/td><td class=\"has-text-align-center\" data-align=\"center\">758<\/td><td class=\"has-text-align-center\" data-align=\"center\">884<\/td><td class=\"has-text-align-center\" data-align=\"center\">980<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30d5\u30a7\u30cb\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">778<\/td><td class=\"has-text-align-center\" data-align=\"center\">769<\/td><td class=\"has-text-align-center\" data-align=\"center\">813<\/td><td class=\"has-text-align-center\" data-align=\"center\">921<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">14% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\/86% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">721<\/td><td class=\"has-text-align-center\" data-align=\"center\">778<\/td><td class=\"has-text-align-center\" data-align=\"center\">784<\/td><td class=\"has-text-align-center\" data-align=\"center\">881<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">65% \u30b8\u30d5\u30a7\u30cb\u30eb\/35% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">794<\/td><td class=\"has-text-align-center\" data-align=\"center\">779<\/td><td class=\"has-text-align-center\" data-align=\"center\">825<\/td><td class=\"has-text-align-center\" data-align=\"center\">938<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">50% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\/50% \u30d5\u30a7\u30cb\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-center\" data-align=\"center\">847<\/td><td class=\"has-text-align-center\" data-align=\"center\">937<\/td><td class=\"has-text-align-center\" data-align=\"center\">958<\/td><td class=\"has-text-align-center\" data-align=\"center\">958<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb<\/td><td class=\"has-text-align-center\" data-align=\"center\">963<\/td><td class=\"has-text-align-center\" data-align=\"center\">1158<\/td><td class=\"has-text-align-center\" data-align=\"center\">998<\/td><td class=\"has-text-align-center\" data-align=\"center\">1230<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u56fa\u5b9a\u76f8\u306e\u9078\u629e<\/h3>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2: <\/strong>\u4e00\u822c\u7684\u306a\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u30b9\u30b1\u30fc\u30eb<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:10%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a.jpg\" alt=\"\" class=\"wp-image-20391\" style=\"object-fit:cover\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<p class=\"has-large-font-size wp-block-paragraph\">\u56fa\u5b9a\u76f8 <\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"608\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP-1024x608.png\" alt=\"\" class=\"wp-image-20511\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP-1024x608.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP-300x178.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP-768x456.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP-1536x911.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724B-figure-2-JP.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u540c\u7cfb\u5217\u306e\u5316\u5408\u7269\u3001\u3064\u307e\u308a\u3001\u540c\u3058\u5316\u5b66\u30af\u30e9\u30b9\u306e\u5206\u6790\u7269\uff08\u4f8b\uff1a\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3001\u30b1\u30c8\u30f3\u985e\u3001\u307e\u305f\u306f\u30a2\u30eb\u30c7\u30d2\u30c9\u985e\u306a\u3069\uff09\u306f\u3001\u4efb\u610f\u306e\u56fa\u5b9a\u76f8\u4e0a\u3067\u6cb8\u70b9\u9806\u306b\u6eb6\u51fa\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u7570\u306a\u308b\u7a2e\u985e\u306e\u5316\u5408\u7269\u304c 1 \u3064\u306e\u30b5\u30f3\u30d7\u30eb\u5185\u3067\u6df7\u5408\u3055\u308c\u308b\u5834\u5408\u3001\u6cb8\u70b9\u3067\u306f\u306a\u304f\u3001\u5206\u6790\u5bfe\u8c61\u7269\u3068\u56fa\u5b9a\u76f8\u306e\u9593\u306e\u5206\u5b50\u9593\u529b\u304c\u4e3b\u8981\u306a\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u56fa\u5b9a\u76f8\u306e\u6975\u6027\u3068\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f\u3001GC\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u4e0a\u3067\u91cd\u8981\u306a\u8003\u616e\u4e8b\u9805<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Restek<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u76f8\u7d44\u6210\uff08USP\u547d\u540d\u6cd5\uff09<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Restek\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Agilent<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Phenomenex<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1683\" target=\"_blank\" rel=\"noopener\">Rxi-1HT<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1676\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1676\" target=\"_blank\" rel=\"noopener\">Rxi-1ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1688\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1688\" target=\"_blank\" rel=\"noopener\">Rtx-1<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">100% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G1\u3001G2\u3001G38\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">400 \u00b0C<br>350 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-1\/HP-1ms,<br>DB-1\/DB-1ms, VF-1ms, CP Sil 5 CB, Ultra 1, DB-1ht, HP-1ms UI, DB-1ms UI<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-1, ZB-1MS,<br>ZB-1HT Inferno<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1685\" target=\"_blank\" rel=\"noopener\">Rxi-5HT<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1691\" target=\"_blank\" rel=\"noopener\">Rtx-5ms<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1675\" target=\"_blank\" rel=\"noopener\">Rxi-5ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1689\" target=\"_blank\" rel=\"noopener\">Rtx-5<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">5% \u30b8\u30d5\u30a7\u30cb\u30eb\/95% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G27\u3001G36\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">400 \u00b0C<br>350 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-5\/HP-5ms, DB-5, Ultra 2, DB-5ht,<br>VF-5ht, CP-Sil 8 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-5, ZB-5HT Inferno, ZB-5ms<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1679\" target=\"_blank\" rel=\"noopener\">Rxi-5Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">5%\uff081,4-\u30d3\u30b9\uff08\u30b8\u30e1\u30c1\u30eb\u30b7\u30ed\u30ad\u30b7\uff09\u30d5\u30a7\u30cb\u30ec\u30f3\/95% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">350 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-5ms UI,<br>DB-5ms,VF-5ms<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-5msi<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1678\" target=\"_blank\" rel=\"noopener\">Rxi-XLB<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30d7\u30ed\u30d7\u30e9\u30a4\u30a8\u30bf\u30ea\u30d5\u30a7\u30fc\u30ba<\/td><td class=\"has-text-align-left\" data-align=\"left\">360 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-XLB, VF-Xms<\/td><td class=\"has-text-align-left\" data-align=\"left\">MR1, ZB-XLB<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1692\" target=\"_blank\" rel=\"noopener\">Rtx-20<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">20% \u30b8\u30d5\u30a7\u30cb\u30eb\/80% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G28\u3001G32\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">320 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1693\" target=\"_blank\" rel=\"noopener\">Rtx-35<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">35% \u30b8\u30d5\u30a7\u30cb\u30eb\/65% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G42\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">320 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-35, DB-35<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-35<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1682\" target=\"_blank\" rel=\"noopener\">Rxi-35Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u975e\u516c\u958b<\/td><td class=\"has-text-align-left\" data-align=\"left\">360 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-35ms, DB-35ms UI, VF-35ms<\/td><td class=\"has-text-align-left\" data-align=\"left\">MR2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1695\" target=\"_blank\" rel=\"noopener\">Rtx-50<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30d5\u30a7\u30cb\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G3\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">320 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1673\" target=\"_blank\" rel=\"noopener\">Rxi-17<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">50% \u30b8\u30d5\u30a7\u30cb\u30eb\/50% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">320 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-17ms, VF-17ms,<br>CP Sil 24 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-50<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1686\" target=\"_blank\" rel=\"noopener\">Rxi-17Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u975e\u516c\u958b<\/td><td class=\"has-text-align-left\" data-align=\"left\">360 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-17ms, VF-17ms,<br>CP Sil 24 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-50<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1696\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1696\" target=\"_blank\" rel=\"noopener\">Rtx-65<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">65% \u30b8\u30d5\u30a7\u30cb\u30eb\/35% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G17\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">300 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1674\" target=\"_blank\" rel=\"noopener\">Rxi-624Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u975e\u516c\u958b<\/td><td class=\"has-text-align-left\" data-align=\"left\">320 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-624 UI, VF-624ms, CP-Select 624 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-624<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1704\" target=\"_blank\" rel=\"noopener\">Rtx-1301<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1703\" target=\"_blank\" rel=\"noopener\">Rtx-624<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">6% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\/94% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G43\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">280 \u00b0C<br>240 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-1301, DB-624,<br>CP-1301, VF-1301ms, VF-624ms<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-624<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1706\" target=\"_blank\" rel=\"noopener\">Rtx-1701<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">14% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\/86% \u30b8\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G46\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">280 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-1701, VF-1701ms, CP Sil 19 CB,<br>VF-1701 Pesticides, DB-1701R<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-1701, ZB-1701P<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1698\" target=\"_blank\" rel=\"noopener\">Rtx-200<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G6\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">360 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-200, VF-200ms, DB-210<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1699\" target=\"_blank\" rel=\"noopener\">Rtx-200ms<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G6\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">340 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-200, VF-200ms, DB-210<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1700\" target=\"_blank\" rel=\"noopener\">Rtx-225<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">50% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30e1\u30c1\u30eb\/50% \u30d5\u30a7\u30cb\u30eb\u30e1\u30c1\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G7\u3001G19\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">240 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-225ms,<br>CP Sil 43 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1701\" target=\"_blank\" rel=\"noopener\">Rtx-440<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u975e\u516c\u958b<\/td><td class=\"has-text-align-left\" data-align=\"left\">340 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"2\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1707\" target=\"_blank\" rel=\"noopener\">Rtx-2330<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">90% \u30d3\u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\/10% \u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\uff08G48\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">275 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">VF-23ms<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1722\" target=\"_blank\" rel=\"noopener\">Rt-2560<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30d3\u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">250 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-88, CP Sil 88<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1721\" target=\"_blank\" rel=\"noopener\">Rtx-Wax<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08G14\u3001G15\u3001G16\u3001G20\u3001G39\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">250 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">CP-Wax 52 CB,<br>DB-Wax, DB-WAX UI<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-WAX<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1725\" target=\"_blank\" rel=\"noopener\">Stabilwax<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08G14\u3001G15\u3001G16\u3001G20\u3001G39\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">260 \u00b0C<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-INNOWax,<br>VF-WaxMS<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-WAXPlus<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">* \u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306f\u30ab\u30e9\u30e0\u306e\u819c\u539a\u306b\u3088\u3063\u3066\u5909\u308f\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> \u7279\u5b9a\u306e\u5206\u6790\u7528\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u5c02\u7528\u306e\u56fa\u5b9a\u76f8<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>Restek<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Agilent<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Supelco<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Macherey-Nagel<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>SGE<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>Phenomenex<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1718\" target=\"_blank\" rel=\"noopener\">Rtx-Volatile Amine<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u30a2\u30df\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">CP-VolAmine<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1690\" target=\"_blank\" rel=\"noopener\">Rtx-5Amine<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a2\u30df\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">CP-Sil 8 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA 5 Amine<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1694\" target=\"_blank\" rel=\"noopener\">Rtx-35Amine<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a2\u30df\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1727\" target=\"_blank\" rel=\"noopener\">Stabilwax-DB<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a2\u30df\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\">CAM, CP WAX 51<\/td><td class=\"has-text-align-left\" data-align=\"left\">Carbowax Amine<\/td><td class=\"has-text-align-left\" data-align=\"left\">FS-CW 20 M-AM<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1726\" target=\"_blank\" rel=\"noopener\">Stabilwax-DA<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u904a\u96e2\u8102\u80aa\u9178<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-FFAP,<br>DB-FFAP,<br>VF-DA,<br>CP WAX58 CB,<br>CP-FFAP CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">Nukol<\/td><td class=\"has-text-align-left\" data-align=\"left\">PERMABOND FFAP,<br>OPTIMA FFAP,<br>OPTIMA FFAP Plus<\/td><td class=\"has-text-align-left\" data-align=\"left\">BP-21<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-FFAP<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u30ad\u30e9\u30eb\u30ab\u30e9\u30e0<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1834\" target=\"_blank\" rel=\"noopener\">Rt-\u03b2DEXm<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1835\" target=\"_blank\" rel=\"noopener\">Rt-\u03b2DEXsm<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1836\" target=\"_blank\" rel=\"noopener\">Rt-\u03b2DEXse<\/a>,<br>Rt-\u03b2DEXsp,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1838\" target=\"_blank\" rel=\"noopener\">Rt-\u03b2DEXsa<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1839\" target=\"_blank\" rel=\"noopener\">Rt-\u03b2DEXcst<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1840\" target=\"_blank\" rel=\"noopener\">Rt-\u03b3DEXsa<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30ad\u30e9\u30eb\u5316\u5408\u7269<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u98df\u54c1\u3001\u9999\u6599\u3001\u304a\u3088\u3073\u30d5\u30ec\u30b0\u30e9\u30f3\u30b9<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1722\" target=\"_blank\" rel=\"noopener\">Rt-2560<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30b7\u30b9\/\u30c8\u30e9\u30f3\u30b9\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\uff08FAME\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-88<\/td><td class=\"has-text-align-left\" data-align=\"left\">SPB-2560<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12498\" target=\"_blank\" rel=\"noopener\">FAMEWAX<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6d77\u6d0b\u6cb9<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-FATWAX UI<\/td><td class=\"has-text-align-left\" data-align=\"left\">Omegawax<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1697\" target=\"_blank\" rel=\"noopener\">Rtx-65TG<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c8\u30ea\u30b0\u30ea\u30bb\u30ea\u30c9<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1681\" target=\"_blank\" rel=\"noopener\">Rxi-PAH<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAHs\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">Agilent Select PAH<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u77f3\u6cb9\u304a\u3088\u3073\u77f3\u6cb9\u5316\u5b66<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1687\" target=\"_blank\" rel=\"noopener\">Rxi-LAO<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">Linear alpha olefin impurities<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19763\" target=\"_blank\" rel=\"noopener\">Rt-Alumina BOND\/CFC<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u5869\u7d20\u5316\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff08CFC\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1750\" target=\"_blank\" rel=\"noopener\">Rt-Alumina BOND\/MAPD<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u3001\u304a\u3088\u3073\u30a2\u30bb\u30c1\u30ec\u30f3\u306e\u5fae\u91cf\u5206\u6790<\/td><td class=\"has-text-align-left\" data-align=\"left\">Select Al\u20820\u2083 MAPD<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1712\" target=\"_blank\" rel=\"noopener\">Rtx-DHA<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8a73\u7d30\u306a\u70ad\u5316\u6c34\u7d20\u5206\u6790<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-PONA, DB-Petro, CP Sil PONA CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">Petrocol DH<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">BP1PONA<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1708\" target=\"_blank\" rel=\"noopener\">Rtx-2887<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1741\" target=\"_blank\" rel=\"noopener\">MXT-2887<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u70ad\u5316\u6c34\u7d20\uff08ASTM D2887\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-2887<\/td><td class=\"has-text-align-left\" data-align=\"left\">Petrocol 2887,<br>Petrocol EX2887<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">D3606<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30a8\u30bf\u30ce\u30fc\u30eb\uff08ASTM D3606\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1723\" target=\"_blank\" rel=\"noopener\">Rt-TCEP<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30ac\u30bd\u30ea\u30f3\u4e2d\u306e\u82b3\u9999\u65cf\u304a\u3088\u3073\u9178\u7d20\u7cfb\u5316\u5408\u7269<\/td><td class=\"has-text-align-left\" data-align=\"left\">CP-TCEP<\/td><td class=\"has-text-align-left\" data-align=\"left\">TCEP<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1731\" target=\"_blank\" rel=\"noopener\">MXT-1HT SimDist<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u7591\u4f3c\u84b8\u7559<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-HT-SimDis,<br>CP-SimDist,<br>CP-SimDist Ultimetal<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">BPX1<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-1XT SimDist<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1710\" target=\"_blank\" rel=\"noopener\">Rtx-Biodiesel TG<\/a>,<br><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1744\" target=\"_blank\" rel=\"noopener\">MXT-Biodiesel TG<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb\u4e2d\u306e\u30c8\u30ea\u30b0\u30ea\u30bb\u30ea\u30c9<\/td><td class=\"has-text-align-left\" data-align=\"left\">Biodiesel,<br>Select Biodiesel<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA Biodiesel<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-Bioethanol<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u81e8\u5e8a\/\u6cd5\u533b\u5b66<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1709\" target=\"_blank\" rel=\"noopener\">Rtx-BAC Plus 1<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8840\u4e2d\u30a2\u30eb\u30b3\u30fc\u30eb\u691c\u67fb<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-ALC1<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-BAC1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1709\" target=\"_blank\" rel=\"noopener\">Rtx-BAC Plus 2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u8840\u4e2d\u30a2\u30eb\u30b3\u30fc\u30eb\u691c\u67fb<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-ALC2<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-BAC2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u533b\u85ac\u54c1<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1674\" target=\"_blank\" rel=\"noopener\">Rxi-624Sil MS (G43)<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u63ee\u767a\u6027\u4e0d\u7d14\u7269\uff08USP &lt;467&gt;\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-624,<br>VF-624ms,<br>CP-Select 624 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA 624 LB<\/td><td class=\"has-text-align-left\" data-align=\"left\">BP624<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-624<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1689\" target=\"_blank\" rel=\"noopener\">Rtx-5 (G27)<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u63ee\u767a\u6027\u4e0d\u7d14\u7269\uff08USP &lt;467&gt;\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-5, DB-5,<br>CP Sil 8 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">SPB-5<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA 5<\/td><td class=\"has-text-align-left\" data-align=\"left\">BP5<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1725\" target=\"_blank\" rel=\"noopener\">Stabilwax (G16)<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u63ee\u767a\u6027\u4e0d\u7d14\u7269\uff08USP &lt;467&gt;\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">HP-INNOWax,<br>CP Wax 52 CB,<br>VF-WAX MS<\/td><td class=\"has-text-align-left\" data-align=\"left\">Supelcowax-10<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA WAXplus<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-WAXplus<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"7\"><strong>\u74b0\u5883<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1680\" target=\"_blank\" rel=\"noopener\">Rxi-SVOCms<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-UI 8270D<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">&nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-SemiVolatiles<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1679\" target=\"_blank\" rel=\"noopener\">Rxi-5Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-5ms,<br>DB-5msUI,<br>VF-5ms,<br>CP-Sil 8 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">SLB-5ms<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA 5MS Accent<\/td><td class=\"has-text-align-left\" data-align=\"left\">BPX5<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-5msi<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1717\" target=\"_blank\" rel=\"noopener\">Rtx-VMS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (EPA Methods 8260, 624, 524)<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1674\" target=\"_blank\" rel=\"noopener\">Rxi-624Sil MS<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (EPA Methods 624)<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-624,<br>VF-624ms,<br>CP-Select 624 CB<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">OPTIMA 624 LB<\/td><td class=\"has-text-align-left\" data-align=\"left\">BP624<\/td><td class=\"has-text-align-left\" data-align=\"left\">ZB-624<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1702\" target=\"_blank\" rel=\"noopener\">Rtx-502.2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (EPA Methods 8010, 8020, 502.2, 601, 602)<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-502.2<\/td><td class=\"has-text-align-left\" data-align=\"left\">VOCOL<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1719\" target=\"_blank\" rel=\"noopener\">Rtx-Volatiles<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (EPA Methods 8010, 8020, 502.2, 601, 602)<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">VOCOL<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1720\" target=\"_blank\" rel=\"noopener\">Rtx-VRX<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (EPA Methods 8010, 8020, 502.2, 601, 602)<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-VRX<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1711\" target=\"_blank\" rel=\"noopener\">Rtx-CLPesticides<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1711\" target=\"_blank\" rel=\"noopener\">Rtx-CLPesticides2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1705\" target=\"_blank\" rel=\"noopener\">Rtx-1614<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u81ed\u7d20\u7cfb\u96e3\u71c3\u5264<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1716\" target=\"_blank\" rel=\"noopener\">Rtx-PCB<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30dd\u30ea\u5869\u5316\u30d3\u30d5\u30a7\u30cb\u30eb\uff08PCB\uff09\u540c\u7cfb\u4f53<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1678\" target=\"_blank\" rel=\"noopener\">Rxi-XLB<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30dd\u30ea\u5869\u5316\u30d3\u30d5\u30a7\u30cb\u30eb\uff08PCB\uff09\u540c\u7cfb\u4f53<\/td><td class=\"has-text-align-left\" data-align=\"left\">DB-XLB,VF-XMS<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">MR1, ZB-XLB<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1715\" target=\"_blank\" rel=\"noopener\">Rtx-OPPesticides<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u30ea\u30f3\u7cfb\u8fb2\u85ac<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1715\" target=\"_blank\" rel=\"noopener\">Rtx-OPPesticides2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u6709\u6a5f\u30ea\u30f3\u7cfb\u8fb2\u85ac<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1713\" target=\"_blank\" rel=\"noopener\">Rtx-Dioxin2<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u304a\u3088\u3073\u30d5\u30e9\u30f3<\/td><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"5\"><strong>RESTEK INNOVATION<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1714\" target=\"_blank\" rel=\"noopener\">Rtx-Mineral Oil<\/a><\/td><td class=\"has-text-align-left\" data-align=\"left\">DIN EN ISO 9377-2<\/td><td class=\"has-text-align-left\" data-align=\"left\">Select Mineral Oil<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#section_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec2\">2. \u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u306b\u57fa\u3065\u3044\u305f\u30ab\u30e9\u30e0\u306e\u819c\u539a\u3068\u5185\u5f84\u306e\u9078\u629e<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"69\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02-1024x69.jpg\" alt=\"\" class=\"wp-image-18339\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02-1024x69.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02-300x20.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02-768x52.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02-1536x104.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u305f\u3089\u3001\u6700\u9069\u306a\u5206\u96e2\u80fd\u3068\u901f\u5ea6\u3092\u5f97\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u3092\u4e0e\u3048\u308b\u30ab\u30e9\u30e0\u306e\u819c\u539a\u3068\u5185\u5f84\u306e\u7d44\u307f\u5408\u308f\u305b\u3092\u6c7a\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4fdd\u6301\u4fc2\u6570\uff08retention factor\uff09\u306f\u3001\u300c\u4fdd\u6301\u4fc2\u6570\uff08capacity factor\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u3068\u6df7\u540c\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u306f\u3001\u5206\u6790\u7a2e\u304c\u56fa\u5b9a\u76f8\u306b\u6ede\u5728\u3059\u308b\u6642\u9593\u3068\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306b\u6ede\u5728\u3059\u308b\u6642\u9593\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u30eb\u30fc\u30eb\u3068\u3057\u3066\u3001\u819c\u539a\u304c\u539a\u3044\u307b\u3069\u3001\u307e\u305f\u5185\u5f84\u304c\u5c0f\u3055\u3044\u307b\u3069\u3001\u5206\u6790\u7a2e\u306f\u4fdd\u6301\u3055\u308c\u307e\u3059\u3002\u6e29\u5ea6\u304c\u4e0a\u6607\u3059\u308b\u3068k\u306f\u6e1b\u5c11\u3059\u308b\u305f\u3081\u3001\u9ad8\u6e29\u3067\u306f\u5206\u6790\u7a2e\u304c\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306b\u9577\u304f\u6ede\u5728\u3057\u3001\u4fdd\u6301\u304c\u77ed\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u306b\u306f\u3001\u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u306e\u5024\u304c\u5927\u304d\u3059\u304e\u308b\u3068\u30d4\u30fc\u30af\u5e45\u304c\u5e83\u304c\u308a\u3001\u5206\u96e2\u6027\u80fd\u304c\u4f4e\u4e0b\u3057\u3001\u30d4\u30fc\u30af\u304c\u91cd\u306a\u3063\u305f\u308a\u5171\u6eb6\u51fa\u3057\u305f\u308a\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u96e2\u80fd\u3092\u6700\u5927\u306b\u3059\u308b\u306b\u306f\u72ed\u304f\u3066\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u304c\u91cd\u8981\u3067\u3042\u308b\u305f\u3081\u3001\u76ee\u6a19\u306f\u3001\u5206\u96e2\u304c\u3067\u304d\u3001\u304b\u3064\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u640d\u306a\u308f\u308c\u306a\u3044\u3088\u3046\u306b\u3001\u5341\u5206\u306a\u4fdd\u6301\u4fc2\u6570\u3092\u6301\u3064\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u305f\u3089\u3001\u8a31\u5bb9\u53ef\u80fd\u306a\u4fdd\u6301\u4fc2\u6570\u3092\u5f97\u308b\u305f\u3081\u306b\u30ab\u30e9\u30e0\u306e\u819c\u539a\u3001\u30ab\u30e9\u30e0\u5185\u5f84\u3001\u304a\u3088\u3073\u6eb6\u51fa\u6e29\u5ea6\u3092\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306e\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u91cf\u304c\u30ab\u30e9\u30e0\u306e\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u3092\u8d85\u3048\u308b\u3068\u3001\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3001\u518d\u73fe\u6027\u306e\u4f4e\u4e0b\u3001\u304a\u3088\u3073\u30d4\u30fc\u30af\u306e\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u304c\u767a\u751f\u3057\u307e\u3059\u3002\u7d14\u5ea6\u5206\u6790\u306a\u3069\u306e\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u904e\u8ca0\u8377\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u3088\u308a\u539a\u3044\u819c\u539a\u3092\u5099\u3048\u305f\u5927\u304d\u3044\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u819c\u539a\u306e\u9078\u629e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u819c\u539a\uff08\u03bcm\uff09\u306f\u3001\u5404\u30b5\u30f3\u30d7\u30eb\u6210\u5206\u306e\u4fdd\u6301\u3068\u30ab\u30e9\u30e0\u306e\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u306e\u4e21\u65b9\u306b\u76f4\u63a5\u5f71\u97ff\u3057\u307e\u3059\u3002\u6975\u3081\u3066\u63ee\u767a\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u3092\u5206\u6790\u3059\u308b\u969b\u306b\u306f\u3001\u539a\u819c\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u4fdd\u6301\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u819c\u539a\u304c\u539a\u3044\u3053\u3068\u306b\u3088\u308a\u3001\u5316\u5408\u7269\u304c\u56fa\u5b9a\u76f8\u306b\u3068\u3069\u307e\u308b\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u3001\u52b9\u7387\u3088\u3044\u5206\u96e2\u304c\u5b9f\u73fe\u3057\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u306f\u3001\u8584\u819c\u30ab\u30e9\u30e0\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u819c\u539a\u304c\u8584\u3044\u307b\u3069\u3001\u5206\u6790\u7a2e\u306e\u30ab\u30e9\u30e0\u5185\u6ede\u7559\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u3001\u9ad8\u3044\u6eb6\u51fa\u6e29\u5ea6\u3067\u767a\u751f\u3057\u304c\u3061\u306a\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u308b\u304b\u3089\u3067\u3059\u3002<strong>Figure 3<\/strong>\u3092\u4f7f\u7528\u3057\u3066\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u6700\u9069\u306a\u819c\u539a\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4e00\u822c\u7684\u306a\u539f\u5247\u3068\u3057\u3066\u3001\u819c\u539a\u304c\u539a\u3044\u307b\u3069\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u304c\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0\u819c\u539a\u306b\u57fa\u3065\u304f\u7279\u6027\u3068\u63a8\u5968\u3055\u308c\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:10%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a.jpg\" alt=\"\" class=\"wp-image-20391\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-02a-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<p class=\"has-large-font-size wp-block-paragraph\">\u819c\u539a <\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"528\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b-1024x528.png\" alt=\"\" class=\"wp-image-29973\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b-1024x528.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b-300x155.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b-768x396.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b-1536x792.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-2-figure-article-GNAR1724A-03b.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u819c\u539a\u306e\u539a\u3055\u307e\u305f\u306f\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u5909\u66f4\u3059\u308b\u969b\u306b\u306f\u3001\u6cb8\u70b9\u306e\u9806\u5e8f\u304c\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3092\u518d\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u5185\u5f84\uff08ID\uff09\u306e\u9078\u629e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306e\u5185\u5f84\uff08ID\uff09\u306f\u819c\u539a\u307b\u3069\u4fdd\u6301\u4fc2\u6570\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u4fdd\u6301\u4fc2\u6570\uff08k\uff09\u3092\u8003\u616e\u3057\u3066\u30ab\u30e9\u30e0ID\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001\u899a\u3048\u3066\u304a\u304f\u3079\u304d\u4e00\u822c\u7684\u306a\u6cd5\u5247\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u306f\u3001\u5185\u5f84\u304c\u5c0f\u3055\u3044\u30ab\u30e9\u30e0\u306f\u3001\u5185\u5f84\u304c\u5927\u304d\u3044\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u4fdd\u6301\u4fc2\u6570\u304c\u9ad8\u304f\u306a\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u306f\u3001\u30ab\u30e9\u30e0\u5185\u306e\u79fb\u52d5\u76f8\uff08\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\uff09\u306e\u5bb9\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u3067\u3059\u3002\u5185\u5f84\u304c\u5c0f\u3055\u3044\u3068k\u306e\u5024\u304c\u9ad8\u304f\u306a\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u30ab\u30e9\u30e0\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u4f4e\u5206\u5b50\u304b\u3089\u9ad8\u5206\u5b50\u307e\u3067\u306e\u7bc4\u56f2\u306e\u5316\u5408\u7269\u304c\u5b58\u5728\u3059\u308b\u8907\u96d1\u306a\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\uff08<strong>Figure 4<\/strong>\uff09\u3002\u6700\u9ad8\u306e\u5206\u96e2\u80fd\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u5185\u5f84\u3068\u819c\u539a\u306e\u4e21\u65b9\u3092\u540c\u6642\u306b\u6700\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u306b\u7559\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:\u00a0<\/strong>\u30ab\u30e9\u30e0\u5185\u5f84\u306b\u57fa\u3065\u304f\u7279\u6027\u3068\u63a8\u5968\u3055\u308c\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:10%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-04a.jpg\" alt=\"\" class=\"wp-image-20415\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-04a.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-04a-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-04a-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<p class=\"has-large-font-size wp-block-paragraph\">\u5185\u5f84<\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"479\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu-1024x479.png\" alt=\"\" class=\"wp-image-24531\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu-1024x479.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu-300x140.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu-768x359.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu-1536x719.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724G-Figure-4-JP-suzu.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u5185\u5f84\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u3001\u3069\u306e\u6ce8\u5165\u65b9\u6cd5\u3092\u7528\u3044\u308b\u304b\u306f\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u3001\u30c0\u30a4\u30ec\u30af\u30c8\u3001\u30af\u30fc\u30eb\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u306e\u3044\u305a\u308c\u304b\u306b\u3088&nbsp;\u3063\u3066\u3001\u9069\u3057\u305f\u30ab\u30e9\u30e0\u5185\u5f84\u304c\u7570\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u5f97\u308b\u305f\u3081\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30af\u30fc\u30eb\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u3067\u306f\u30010.53 mm\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u308c\u306f\u30b7\u30ea\u30f3&nbsp;\u30b8\u30cb\u30fc\u30c9\u30eb(26\u30b2\u30fc\u30b8)\u306b\u5408\u3063\u305f\u30ab\u30e9\u30e0\u5185\u5f84\u3060\u304b\u3089\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u691c\u51fa\u5668\u306e\u7a2e\u985e\u3084\u305d\u308c\u306b\u9069\u3057\u305f\u6d41\u91cf\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3068\u3048\u3070\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306b\u306f1.5 mL\/min\u307e\u3067\u306e\u30ab\u30e9\u30e0\u6d41\u91cf\u3067\u3057\u304b\u4f7f\u7528\u3067\u304d\u306a\u3044\u3082\u306e\u3082\u3042\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u6700\u9069\u306a\u30af\u30ed\u30de\u30c8\u5206\u96e2\u3092\u5f97\u308b\u305f\u3081\u306b\u9ad8\u6d41\u91cf\u304c\u5fc5\u8981\u306a0.53 mm\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u306f\u3053\u308c\u306b\u306f\u9069\u3057\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u76f8\u6bd4\uff08\u03b2\uff09\u306b\u3088\u308b\u9078\u629e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u819c\u539a\u3068\u306e\u95a2\u4fc2\u306f\u3001\u76f8\u6bd4\uff08\u03b2\uff09\u3068\u3057\u3066\u8868\u73fe\u3055\u308c\u307e\u3059\u3002\u5927\u53e3\u5f84\u30ab\u30e9\u30e0\u3067\u4e0a\u624b\u304f\u5206\u96e2\u3055\u308c\u3001\u3088\u308a\u901f\u3044\u5206\u6790\u304c\u5fc5\u8981\u306a\u5834\u5408\u3001\u5185\u5f84\u3092\u7e2e\u5c0f\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u89e3\u6027\u80fd\u3092\u72a0\u7272\u306b\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u3080\u3057\u308d\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5185\u5f84\u3092\u5c0f\u3055\u304f\u3057\u3066\u3001\u540c\u69d8\u306e\u5316\u5408\u7269\u306e\u6eb6\u51fa\u30d1\u30bf\u30fc\u30f3\u3092\u7dad\u6301\u3059\u308b\u306b\u306f\u3001\u819c\u539a\u3082\u5909\u66f4\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u8fd1\u3044\u76f8\u6bd4\u306e\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3078\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u79fb\u884c\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306e\u76f8\u6bd4\u3092<strong>Table IV<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u793a\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306b\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3057\u305f\u3044\u3068\u8003\u3048\u308b\u5206\u6790\u8005\u306f\u30010.32 mm x 0.50 \u00b5m\u30ab\u30e9\u30e0\uff08\u03b2 = 160\uff09\u304b\u30890.25 mm x 0.25 \u03bcm\u30ab\u30e9\u30e0\uff08\u03b2 = 250\uff09\u306b\u5207\u308a\u66ff\u3048\u3001\u9069\u5207\u306a\u65b9\u6cd5\u306e\u5909\u63db\u3092\u884c\u3046\u3068\u3001\u975e\u5e38\u306b\u4f3c\u305f\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u91cd\u8981\u306a\u306e\u306f\u3001\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u819c\u539a\u306f\u8a66\u6599\u8ca0\u8377\u91cf\u306b\u5bfe\u3057\u3066\u5171\u901a\u306e\u5f71\u97ff\u3092\u793a\u3057\u3001\u5185\u5f84\u3068\u819c\u539a\u304c\u6e1b\u5c11\u3059\u308b\u3068\u8a66\u6599\u8ca0\u8377\u91cf\u3082\u6e1b\u5c11\u3057\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u3088\u308a\u5c11\u306a\u3044\u30b5\u30f3\u30d7\u30eb\u91cf\u3092\u6ce8\u5165\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3068\u60f3\u5b9a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Table IV:<\/strong> \u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u5bf8\u6cd5\u306e\u76f8\u6bd4\uff08\u03b2\uff09*\u5024\uff08\u540c\u69d8\u306e\u5206\u96e2\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u5185\u5f84\u307e\u305f\u306f\u819c\u539a\u304c\u7570\u306a\u308b\u30ab\u30e9\u30e0\u3078\u79fb\u884c\u3059\u308b\u5834\u5408\u306f\u3001\u540c\u69d8\u306e\u76f8\u6bd4\u3092\u3082\u3064\u30ab\u30e9\u30e0\u3092\u9078\u629e\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\"><strong>\u30ab\u30e9\u30e0\u5185\u5f84\uff08ID\uff09<\/strong><\/td><td colspan=\"7\"><strong>\u819c\u539a (d<sub>f<\/sub>)<\/strong><\/td><\/tr><tr><td><strong>0.10 \u00b5m<\/strong><\/td><td><strong>0.25 \u00b5m<\/strong><\/td><td><strong>0.50 \u00b5m<\/strong><\/td><td><strong>1.0 \u00b5m<\/strong><\/td><td><strong>1.5 \u00b5m<\/strong><\/td><td><strong>3.0 \u00b5m<\/strong><\/td><td><strong>5.0 \u00b5m<\/strong><\/td><\/tr><tr><td>0.18 mm<\/td><td>450<\/td><td>180<\/td><td>90<\/td><td>45<\/td><td>30<\/td><td>15<\/td><td>9<\/td><\/tr><tr><td>0.25 mm<\/td><td>625<\/td><td><strong>250<\/strong><\/td><td>125<\/td><td>63<\/td><td>42<\/td><td>21<\/td><td>13<\/td><\/tr><tr><td>0.32 mm<\/td><td>800<\/td><td>320<\/td><td><strong>160<\/strong><\/td><td>80<\/td><td>53<\/td><td>27<\/td><td>16<\/td><\/tr><tr><td>0.53 mm<\/td><td>1325<\/td><td>530<\/td><td>265<\/td><td>128<\/td><td>88<\/td><td>43<\/td><td>27<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u76f8\u6bd4 (\u03b2) = \u534a\u5f84\/2df \uff08\u6ce8: \u8a08\u7b97\u524d\u306b\u5909\u6570\u3092\u540c\u3058\u5358\u4f4d\u306b\u5909\u63db\u3057\u3066\u304f\u3060\u3055\u3044\u3002\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#section_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec3\">3. \u7406\u8ad6\u6bb5\u6570\uff08N\u3001\u52b9\u7387\uff09\u3092\u8003\u616e\u3057\u305f\u30ab\u30e9\u30e0\u9577\u3001\u5185\u5f84\u3001\u304a\u3088\u3073\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"69\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03-1024x69.jpg\" alt=\"\" class=\"wp-image-18345\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03-1024x69.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03-300x20.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03-768x52.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03-1536x104.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/equation-article-GNAR1724C-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0\u30ab\u30e9\u30e0\u9577\u306e\u9078\u629e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GC\u7528\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306f\u3001\u5185\u5f84\u306b\u5fdc\u3058\u3066\u901a\u5e3810\u300115\u300130\u300160\u3001\u304a\u3088\u3073105\u30e1\u30fc\u30c8\u30eb\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u30ab\u30e9\u30e0\u9577\u3067\u88fd\u9020\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u540c\u3058\u5185\u5f84\u306a\u3089\u30ab\u30e9\u30e0\u9577\u304c\u9577\u3044\u65b9\u304c\u3088\u308a\u9ad8\u3044\u5206\u96e2\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5206\u6790\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u305f\u3081\u3001\u9577\u3044\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u306f\u9ad8\u3044\u5206\u96e2\u80fd\u304c\u8981\u6c42\u3055\u308c\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9650\u5b9a\u3055\u308c\u308b\u3079\u304d\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u30ab\u30e9\u30e0\u9577\u3092\u8003\u616e\u3059\u308b\u306e\u306f\u56fa\u5b9a\u76f8\u304c\u6c7a\u5b9a\u3055\u308c\u305f\u5f8c\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u5206\u96e2\u80fd\u306b\u6700\u5927\u306e\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u5206\u96e2\u4fc2\u6570\u304c\u3001\u5206\u6790\u7a2e\u306b\u5bfe\u3057\u3066\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u306e\u9078\u629e\u3092\u901a\u3058\u3066\u6700\u5927\u5316\u3055\u308c\u308b\u304b\u3089\u3067\u3059\u3002\u30ab\u30e9\u30e0\u9577\u3092\u500d\u306b\u3059\u308b\uff08\u4f8b\uff1a30\u30e1\u30fc\u30c8\u30eb\u304b\u308960\u30e1\u30fc\u30c8\u30eb\uff09\u3068\u3001\u5206\u96e2\u80fd\u306f\u7d0440\uff05\u5411\u4e0a\u3057\u307e\u3059\u304c\u3001\u5206\u6790\u6642\u9593\u306f2\u500d\u306b\u306a\u308b\u4e0a\u306b\u3001\u30b3\u30b9\u30c8\u3082\u304b\u304b\u308a\u307e\u3059\u3002 \u9006\u306b\u3001\u77ed\u3044\u30ab\u30e9\u30e0\u3067\u5206\u96e2\u3067\u304d\u308b\u5834\u5408\uff08\u4f8b\uff1a15\u30e1\u30fc\u30c8\u30eb vs 30\u30e1\u30fc\u30c8\u30eb\uff09\u3001\u5206\u6790\u6642\u9593\u3068\u30ab\u30e9\u30e0\u306e\u30b3\u30b9\u30c8\u306e\u4e21\u65b9\u304c\u4f4e\u6e1b\u3055\u308c\u307e\u3059\u3002<strong>Figure 5<\/strong>\u306b\u793a\u3057\u305f\u306e\u306f\u3001\u4e00\u9023\u306e\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u9577\u306e\u7279\u6027\u3068\u4e00\u822c\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u8981\u7d04\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:\u00a0<\/strong>\u30ab\u30e9\u30e0\u9577\u306b\u57fa\u3065\u304f\u7279\u6027\u3068\u63a8\u5968\u3055\u308c\u308b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:10%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-05a.jpg\" alt=\"\" class=\"wp-image-20427\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-05a.jpg 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-05a-300x300.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-05a-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:90%\">\n<p class=\"has-large-font-size wp-block-paragraph\">\u9577\u3055<\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"501\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b-1024x501.png\" alt=\"\" class=\"wp-image-29985\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b-1024x501.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b-300x147.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b-768x376.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b-1536x752.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-4-figure-article-GNAR1724A-05b.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u5185\u5f84\uff08ID\uff09\u306e\u9078\u629e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c0f\u53e3\u5f84\u306e\u30ab\u30e9\u30e0\u306f\u3001\u5927\u53e3\u5f84\u306e\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u30661\u30e1\u30fc\u30c8\u30eb\u3042\u305f\u308a\u306e\u6bb5\u6570\u304c\u9ad8\u304f\u3001\u30d4\u30fc\u30af\u304c\u3088\u308a\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308b\u3053\u3068\u3067\u512a\u308c\u305f\u5206\u96e2\u52b9\u7387\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3088\u308a\u8907\u96d1\u306a\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u5c0f\u53e3\u5f84\u306e\u30ab\u30e9\u30e0\u306f\u8fd1\u63a5\u3057\u305f\u30d4\u30fc\u30af\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u4e00\u65b9\u3067\u3001\u5c0f\u53e3\u5f84\u306e\u30ab\u30e9\u30e0\u306b\u306f\u3001\u8a66\u6599\u8ca0\u8377\u5bb9\u91cf\u304c\u4f4e\u3044\u3068\u3044\u3046\u30c7\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u306b0.18 mm\u4ee5\u4e0b\u306e\u5c0f\u53e3\u5f84\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u6642\u306e\u904e\u8ca0\u8377\u3092\u907f\u3051\u3001\u30ab\u30e9\u30e0\u52b9\u7387\u306e\u4f4e\u4e0b\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u9ad8\u52b9\u7387\u306a\u6ce8\u5165\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u5185\u5f84\u306b\u57fa\u3065\u304f\u30ab\u30e9\u30e0\u306e\u7279\u6027\u306f\u3001<strong>Table V<\/strong>\u306b\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306b\u30010.25 mm\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u306f\u5206\u6790\u6642\u9593\u3068\u8a66\u6599\u8ca0\u8377\u91cf\u3092\u540c\u6642\u306b\u8003\u616e\u3057\u306a\u304c\u3089\u3001\u6700\u3082\u52b9\u7387\u7684\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u7406\u7531\u306b\u52a0\u3048\u3001\u30ab\u30e9\u30e0\u51fa\u53e3\u306e\u6d41\u91cf\u304c\u4f4e\u3044\u3068\u3044\u3046\u3053\u3068\u3082\u3042\u308a\u3001GC\/MS\u5206\u6790\u306b\u304a\u3044\u3066\u30820.25 mm\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u306f\u6700\u9069\u306a\u9078\u629e\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>&nbsp;Table V:<\/strong> \u5185\u5f84\u306b\u57fa\u3065\u304f\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u306e\u7279\u6027<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\"><strong>\u7279\u6027<\/strong><\/td><td colspan=\"6\"><strong>\u30ab\u30e9\u30e0\u5185\u5f84 (mm)<\/strong><\/td><\/tr><tr><td><strong>0.10<\/strong><\/td><td><strong>0.15<\/strong><\/td><td><strong>0.18<\/strong><\/td><td><strong>0.25<\/strong><\/td><td><strong>0.32<\/strong><\/td><td><strong>0.53<\/strong><\/td><\/tr><tr><td>\u7a92\u7d20\u306e\u6d41\u91cf (mL\/min)<\/td><td>0.2<\/td><td>0.3<\/td><td>0.3<\/td><td>0.4<\/td><td>0.6<\/td><td>0.9<\/td><\/tr><tr><td>\u30d8\u30ea\u30a6\u30e0\u306e\u6d41\u91cf (mL\/min)<\/td><td>0.6<\/td><td>0.8<\/td><td>1.0<\/td><td>1.4<\/td><td>1.8<\/td><td>3.0<\/td><\/tr><tr><td>\u6c34\u7d20\u306e\u6d41\u91cf (mL\/min)<\/td><td>0.7<\/td><td>1.1<\/td><td>1.8<\/td><td>1.8<\/td><td>2.3<\/td><td>3.7<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf (ng)<\/td><td>2.5<\/td><td>10<\/td><td>20<\/td><td>50<\/td><td>125<\/td><td>500<\/td><\/tr><tr><td>\u7406\u8ad6\u6bb5\u6570 \/ \u30e1\u30fc\u30c8\u30eb<\/td><td>11,000<\/td><td>7000<\/td><td>6000<\/td><td>4000<\/td><td>3000<\/td><td>2000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\u91c8\uff1a\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u30d5\u30ed\u30fc\u306f\u6700\u5927\u306e\u52b9\u7387\u306e\u305f\u3081\u306e\u3082\u306e\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u306f\u3042\u304f\u307e\u3067\u898b\u7a4d\u3082\u308a\u3067\u3059\u3002\u5b9f\u969b\u306e\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u306f\u3001\u819c\u306e\u539a\u3055\u3084\u5206\u6790\u7269\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u203b\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3092\u5909\u66f4\u3059\u308b\u969b\u306b\u306f\u3001\u6eb6\u51fa\u3059\u308b\u9806\u5e8f\u304c\u5909\u308f\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3092\u518d\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e\uff08\u7a2e\u985e\u3068\u7dda\u901f\u5ea6\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u9078\u629e\u3068\u7dda\u901f\u5ea6\u306f\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u52b9\u7387\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u3053\u308c\u306fvan Deemter\u30d7\u30ed\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3068\u3088\u304f\u7406\u89e3\u3067\u304d\u307e\u3059\uff08<strong>Figure 6<\/strong>\uff09\u3002\u5404\u30ac\u30b9\u306e\u6700\u9069\u7dda\u901f\u5ea6\u306f\u66f2\u7dda\u306e\u6700\u3082\u4f4e\u3044\u70b9\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u7406\u8ad6\u6bb5\u76f8\u5f53\u9ad8\u3055\uff08H\uff09\u306f\u6700\u5c0f\u306b\u3001\u52b9\u7387\u306f\u6700\u5927\u306b\u306a\u308a\u307e\u3059\u3002<strong>Figure 1<\/strong>\u306b\u793a\u3057\u305f\u901a\u308a\u3001\u6700\u9069\u306a\u7dda\u901f\u5ea6\u306f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3054\u3068\u306b\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7a92\u7d20\u306f\u6700\u3082\u512a\u308c\u305f\u52b9\u7387\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u3001van Deemter\u30d7\u30ed\u30c3\u30c8\u3067\u306f\u6700\u9069\u7dda\u901f\u5ea6\u4ed8\u8fd1\u304c\u6025\u52fe\u914d\u306b\u306a\u3063\u3066\u304a\u308a\u3001\u7dda\u901f\u5ea6\u306e\u5c0f\u3055\u306a\u5909\u5316\u304c\u52b9\u7387\u306b\u5927\u304d\u306a\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u7a92\u7d20\u3068\u6bd4\u8f03\u3057\u3066\u3001\u30d8\u30ea\u30a6\u30e0\u306f\u6700\u9069\u7dda\u901f\u5ea6\u4ed8\u8fd1\u306e\u52fe\u914d\u306f\u7de9\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u52b9\u7387\u306f\u308f\u305a\u304b\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u6700\u9069\u306a\u901f\u5ea6\u304c\u901f\u3044\u305f\u3081\u3001\u30d8\u30ea\u30a6\u30e0\u3067\u306f\u5206\u6790\u6642\u9593\u304c\u7a92\u7d20\u3092\u4f7f\u7528\u3057\u305f\u3068\u304d\u306e\u7d04\u534a\u5206\u3068\u306a\u308a\u3001\u901f\u5ea6\u304c\u82e5\u5e72\u5909\u308f\u3063\u305f\u3068\u3057\u3066\u3082\u52b9\u7387\u306e\u4f4e\u4e0b\u306f\u308f\u305a\u304b\u3067\u3059\u3002\u4e00\u822c\u7684\u306a3\u7a2e\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u3046\u3061\u3001\u6c34\u7d20\u306fvan Deemter\u30ab\u30fc\u30d6\u304c\u6700\u3082\u5e73\u5766\u3067\u3042\u308b\u305f\u3081\u3001\u5206\u6790\u6642\u9593\u304c\u6700\u3082\u77ed\u304f\u3001\u9ad8\u3044\u52b9\u7387\u304c\u5f97\u3089\u308c\u308b\u7dda\u901f\u5ea6\u306e\u7bc4\u56f2\u304c\u6700\u3082\u5e83\u304f\u306a\u308a\u307e\u3059\u3002\u4f7f\u7528\u3059\u308b\u30ac\u30b9\u306e\u7a2e\u985e\u306b\u95a2\u4fc2\u306a\u304f\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u30d8\u30c3\u30c9\u5727\u306f\u30ab\u30e9\u30e0\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u5b9f\u884c\u4e2d\u306f\u4e00\u5b9a\u3067\u3059\u304c\u3001\u5e73\u5747\u7dda\u901f\u5ea6\u306f\u30d7\u30ed\u30b0\u30e9\u30e0\u4e2d\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u305f\u3081\u5727\u529b\u3092\u4e00\u5b9a\u306b\u3057\u3066\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u6700\u3082\u91cd\u8981\u306a\u5206\u96e2\u306b\u5bfe\u3057\u3066\u6700\u9069\u306a\u7dda\u901f\u5ea6\u3092\u8a2d\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u8fd1\u5e74\u3001\u4e00\u822c\u7684\u306b\u306f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u96fb\u5b50\u5727\u529b\u5236\u5fa1\uff08EPC\uff09\u306b\u3088\u308a\u5b9a\u6d41\u91cf\u306f\u3082\u3061\u308d\u3093\u5b9a\u7dda\u901f\u5ea6\u306e\u5236\u5fa1\u307e\u3067\u3082\u53ef\u80fd\u306b\u306a\u308a\u3001\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u4e2d\u3067\u3082\u9ad8\u3044\u52b9\u7387\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u52b9\u7387\u306b\u306f\u76f4\u63a5\u95a2\u4fc2\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7a2e\u985e\u306b\u3064\u3044\u3066\u4ed6\u306e\u91cd\u8981\u306a\u7559\u610f\u70b9\u3068\u3057\u3066\u3001\u30ab\u30e9\u30e0\u51fa\u53e3\u304c\u771f\u7a7a\u306b\u306a\u308b\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092\u691c\u51fa\u5668\u3068\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u304c\u3042\u308a\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u52b9\u7387\u3060\u3051\u3067\u306f\u306a\u304f\u3001\u771f\u7a7a\u30dd\u30f3\u30d7\u306b\u3088\u308b\u6392\u51fa\u304c\u5bb9\u6613\u3067\u3042\u308b\u305f\u3081\u3001\u307b\u3068\u3093\u3069\u3059\u3079\u3066\u306e\u5834\u5408\u3067\u6c34\u7d20\u3088\u308a\u30d8\u30ea\u30a6\u30e0\u304c\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306b\u9078\u629e\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u7d20\u306fMS\u30bd\u30fc\u30b9\u5185\u3067\u53cd\u5fdc\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u4e00\u90e8\u306e\u5316\u5408\u7269\u3067\u306f\u597d\u307e\u3057\u304f\u306a\u3044\u30b9\u30da\u30af\u30c8\u30eb\u5909\u5316\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u7a92\u7d20\u306f\u5927\u5e45\u306b\u611f\u5ea6\u3092\u4f4e\u4e0b\u3055\u305b\u308b\u305f\u3081\u3001\u901a\u5e38\u306fGC-MS\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306b\u306f\u4f7f\u7528\u3057\u307e\u305b\u3093\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> \u6700\u9069\u7dda\u901f\u5ea6\u3067\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u6d41\u3059\u3068\u3001\u6240\u5b9a\u306e\u6e29\u5ea6\u3067\u306e\u52b9\u7387\u304c\u6700\u3082\u826f\u304f\u306a\u308a\u307e\u3059\u3002\u8d64\u4e38\u306f\u5404\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6700\u9069\u7dda\u901f\u5ea6\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"564\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06-1024x564.jpg\" alt=\"\" class=\"wp-image-20439\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06-1024x564.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06-300x165.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06-768x423.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06-1536x846.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-06.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#section_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec4\">4. \u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u30d2\u30f3\u30c8<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u57fa\u672c\u7684\u306a\u624b\u9806<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u57fa\u672c\u7684\u306a\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u624b\u9806\u306b\u5f93\u3063\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3001\u691c\u51fa\u5668\u3001\u304a\u3088\u3073\u30ab\u30e9\u30e0\u306b\u95a2\u9023\u3059\u308b\u554f\u984c\u3092\u305d\u308c\u305e\u308c\u5207\u308a\u96e2\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305a\u6700\u521d\u306b\u660e\u3089\u304b\u3067\u3042\u308b\u771f\u76f8\u3092\u78ba\u8a8d\u3057\u3001\u554f\u984c\u3092\u7279\u5b9a\u3057\u89e3\u6c7a\u3059\u308b\u307e\u3067\u3001\u4e00\u5ea6\u306b1\u3064\u3060\u3051\u5909\u66f4\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u57fa\u672c\u7684\u4e8b\u9805\uff08\u4ee5\u4e0b\u53c2\u7167\uff09\u306e\u78ba\u8a8d<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>\u96fb\u6e90<\/li>\n\n\n\n<li>\u96fb\u6c17\u63a5\u7d9a<\/li>\n\n\n\n<li>\u4fe1\u53f7\u63a5\u7d9a<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>\u30ac\u30b9\u306e\u7d14\u5ea6<\/li>\n\n\n\n<li>\u30ac\u30b9\u306e\u6d41\u308c<\/li>\n\n\n\n<li>\u6e29\u5ea6\u8a2d\u5b9a<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>\u30b7\u30ea\u30f3\u30b8\u306e\u72b6\u614b<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u306e\u6e96\u5099<\/li>\n\n\n\n<li>\u5206\u6790\u6761\u4ef6<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u539f\u56e0\u306e\u7279\u5b9a<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u554f\u984c\u3092\u660e\u78ba\u306b\u5b9a\u7fa9\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4f8b\uff1a\u300c\u904e\u53bb4\u65e5\u9593\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u4e2d\u306e\u30d5\u30a7\u30ce\u30fc\u30eb\u306e\u307f\u30d4\u30fc\u30af\u304c\u30c6\u30fc\u30ea\u30f3\u30b0\u3057\u3066\u3044\u307e\u3059\u3002\u300d<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u3084\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u8a18\u9332\u3092\u898b\u76f4\u3057\u3066\u3001\u30c7\u30fc\u30bf\u306e\u50be\u5411\u3084\u554f\u984c\u306e\u6307\u6a19\uff08\u305f\u3068\u3048\u3070\u3001\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u30a8\u30ea\u30a2\u30ab\u30a6\u30f3\u30c8\u304c\u6e1b\u5c11\u3057\u3066\u3044\u308b\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304c\u4e88\u5b9a\u901a\u308a\u306b\u5b9f\u65bd\u3055\u308c\u3066\u3044\u306a\u3044\u7b49\uff09\u3092\u7279\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u539f\u56e0\u3092\u7d5e\u308a\u8fbc\u3080\u305f\u3081\u306b\u8ad6\u7406\u7684\u306a\u624b\u9806\u3092\u8e0f\u3093\u3067\u304f\u3060\u3055\u3044\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u4f5c\u696d\u306e\u6587\u66f8\u5316\u304a\u3088\u3073\u30b7\u30b9\u30c6\u30e0\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u78ba\u8a8d<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u624b\u9806\u3068\u7d50\u679c\u3092\u3059\u3079\u3066\u6587\u66f8\u306b\u6b8b\u3057\u3066\u304a\u304f\u3068\u3001\u6b21\u306e\u554f\u984c\u306e\u7279\u5b9a\u3068\u89e3\u6c7a\u304c\u8fc5\u901f\u306b\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/li>\n\n\n\n<li>\u5fa9\u5143\u3055\u308c\u305f\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5e38\u306b\u30c6\u30b9\u30c8\u30df\u30c3\u30af\u30b9\u3092\u6ce8\u5165\u3057\u3066\u3001\u4ee5\u524d\u306e\u30c7\u30fc\u30bf\u3068\u6bd4\u8f03\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u4f8b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3042\u308b\u5206\u6790\u8005\u304cGC-FID\u5206\u6790\u4e2d\u306b\u30d4\u30fc\u30af\u304c\u8868\u793a\u3055\u308c\u306a\u3044\u3053\u3068\u306b\u6c17\u4ed8\u304d\u307e\u3057\u305f\u3002\u4ee5\u4e0b\u306e\u30d5\u30ed\u30fc\u30c1\u30e3\u30fc\u30c8\u306f\u3001\u539f\u56e0\u3092\u7279\u5b9a\u3057\u554f\u984c\u3092\u4fee\u6b63\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u3067\u304d\u308b\u8ad6\u7406\u7684\u306a\u624b\u9806\u306e\u9032\u884c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"414\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02-1024x414.png\" alt=\"\" class=\"wp-image-29991\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02-1024x414.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02-300x121.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02-768x311.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02-1536x621.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y3-5-diagram-article-GNAR1724A-02.png 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u75c7\u72b6\u3068\u89e3\u6c7a\u7b56<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b63\u78ba\u3067\u518d\u73fe\u6027\u306e\u3042\u308b\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306f\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u5171\u6eb6\u51fa\u3001\u975e\u5bfe\u79f0\u30d4\u30fc\u30af\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u30ce\u30a4\u30ba\u306a\u3069\u306f\u3001\u30ac\u30b9\u30af\u30ed\u30e9\u30dc\u3067\u3088\u304f\u898b\u3089\u308c\u308b\u8ab2\u984c\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u5206\u6790\u4e0a\u306e\u554f\u984c\u3084\u305d\u306e\u4ed6\u306e\u8ab2\u984c\u306f\u3001\u4ee5\u4e0b\u306e\u30d2\u30f3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u5206\u96e2\u3092\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u514b\u670d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u5206\u96e2\u304c\u60aa\u3044<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-01.jpg\" alt=\"Poor Resolution\" width=\"1000\" height=\"1058\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u56fa\u5b9a\u76f8\u304c\u5408\u3063\u3066\u3044\u306a\u3044<\/td><td><ul><li>\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u3068\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u60aa\u3044<\/td><td><ul><li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7dda\u901f\u5ea6\u3068GC\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u6e29\u5ea6\u3092\u6700\u9069\u5316\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9<\/td><td><ul><li>\u30b5\u30f3\u30d7\u30eb\u306e\u6fc3\u5ea6\u3084\u30ab\u30e9\u30e0\u3078\u306e\u30ed\u30fc\u30c9\u91cf\u3092\u8abf\u6574\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u6b63\u3057\u304f\u306a\u3044\u5206\u6790\u6761\u4ef6\u306e\u4f7f\u7528<\/td><td><ul><li>\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u3001\u6d41\u91cf\u3001\u304a\u3088\u3073\u30ab\u30e9\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u4fdd\u6301\u6642\u9593\u306e\u518d\u73fe\u6027\u304c\u4f4e\u3044<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"9\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-02.jpg\" alt=\"Poor Retention Time Reproducibility\" width=\"1000\" height=\"719\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u6f0f\u308c<\/td><td><ul><li>\u6f0f\u308c\u3092\u30c1\u30a7\u30c3\u30af\u3057\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u304a\u3088\u3073\u30d7\u30ec\u30b9\u30bf\u30a4\u30c8\u30b3\u30cd\u30af\u30bf\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u91cd\u8981\u306a\u30b7\u30fc\u30eb\uff08\u4f8b\u3048\u3070\u3001\u30bb\u30d7\u30bf\u3001\uff2f\u30ea\u30f3\u30b0\u3001\u30a4\u30f3\u30ec\u30c3\u30c8\u30c7\u30a3\u30b9\u30af\u306a\u3069\uff09\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u5206\u6790\u6210\u5206\u306e\u5438\u7740<\/td><td><ul><li>\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u304a\u3088\u3073GC\u30ab\u30e9\u30e0\u3092\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3059\u308b <\/li><li>\u9069\u5207\u306b\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u30e9\u30a4\u30ca\u30fc\u3001\u30b7\u30fc\u30eb\u3001\u304a\u3088\u3073\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u5206\u96e2\uff0f\u89e3\u6790\u306e\u554f\u984c<\/td><td><ul><li>\u30b5\u30f3\u30d7\u30eb\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9\u3092\u907f\u3051\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u4e0d\u6b63\u78ba\u306a\u30ab\u30e9\u30e0\uff0f\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0<\/td><td><ul><li>\u30ab\u30e9\u30e0\u6e29\u5ea6\u304a\u3088\u3073\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u8abf\u6574\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\uff0f\u7dda\u901f\u5ea6\u304c\u9593\u9055\u3063\u3066\u3044\u308b\u3001\u307e\u305f\u306f\u4e0d\u5b89\u5b9a<\/td><td><ul><li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3068\u7dda\u901f\u5ea6\u3092\u78ba\u8a8d\u3059\u308b <\/li><li>\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u90e8\u54c1\u3092\u4fee\u7406\u307e\u305f\u306f\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u5236\u5fa1\u306b\u554f\u984c\u304c\u3042\u308b<\/td><td><ul><li>GC\u30aa\u30fc\u30d6\u30f3\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u306e\u63a8\u5968\u7bc4\u56f2\u5185\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30aa\u30fc\u30d6\u30f3\u306e\u5e73\u8861\u5316\u6642\u9593\u304c\u9069\u5207\u3067\u306a\u3044<\/td><td><ul><li>GC\u30aa\u30fc\u30d6\u30f3\u306e\u5e73\u8861\u5316\u6642\u9593\u3092\u5ef6\u9577\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30de\u30cb\u30e5\u30a2\u30eb\u6ce8\u5165\u306e\u5834\u5408\u306e\u3001\u958b\u59cb\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u3066\u304b\u3089\u5b9f\u969b\u306e\u6ce8\u5165\u307e\u3067\u306e\u9045\u5ef6<\/td><td><ul><li>\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u3092\u4f7f\u7528\u3059\u308b\u304b\u3001\u30de\u30cb\u30e5\u30a2\u30eb\u6ce8\u5165\u624b\u9806\u3092\u6a19\u6e96\u5316\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30d4\u30fc\u30af\u306e\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"3\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-03.jpg\" alt=\"Fronting peaks\" width=\"1000\" height=\"817\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u4e0d\u9069\u5207\u306a\u56fa\u5b9a\u76f8<\/td><td><ul><li>\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u306e\u30aa\u30fc\u30d0\u30fc\u30ed\u30fc\u30c9<\/td><td><ul><li>\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059\u304b\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u5e0c\u91c8\u3059\u308b <\/li><li>\u30ab\u30e9\u30e0\u306e\u5185\u5f84\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u819c\u539a\u3092\u5897\u3084\u3059<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30d4\u30fc\u30af\u306e\u30c6\u30fc\u30ea\u30f3\u30b0<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-04.jpg\" alt=\"Tailing peaks\" width=\"1000\" height=\"817\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u8868\u9762\u6d3b\u6027\u307e\u305f\u306f\u6c5a\u67d3\u306b\u8d77\u56e0\u3059\u308b\u5438\u7740<\/td><td><ul><li>\u9069\u5207\u306b\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u304a\u3088\u3073\u6d3b\u6027\u5316\u3055\u308c\u305f\u30e9\u30a4\u30ca\u30fc\u3001\u30b7\u30fc\u30eb\u3001\u304a\u3088\u3073\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b <\/li><li>\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u5074\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3059\u308b <\/li><li>\u30ab\u30e9\u30e0\u304c\u640d\u50b7\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u5316\u5408\u7269\u306e\u5316\u5b66\u7d44\u6210\u306b\u8d77\u56e0\u3059\u308b\u5438\u7740<\/td><td><ul><li>\u5316\u5408\u7269\u3092\u8a98\u5c0e\u4f53\u5316\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b7\u30b9\u30c6\u30e0\u306e\u6f0f\u308c<\/td><td><ul><li>\u3059\u3079\u3066\u306e\u63a5\u7d9a\u90e8\u5206\u3067\u6f0f\u308c\u304c\u306a\u3044\u304b\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u91cd\u8981\u306a\u30b7\u30fc\u30eb\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u53d6\u308a\u4ed8\u3051\u306b\u95a2\u3059\u308b\u554f\u984c<\/td><td><ul><li>\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b <\/li><li>\u30ab\u30e9\u30e0\u304c\u6b63\u3057\u304f\u30ab\u30c3\u30c8\u3055\u308c\u3066\u3044\u308b\u304b\uff08\u6b63\u65b9\u5f62\u3067\u3042\u308b\u304b\uff09\u78ba\u8a8d\u3059\u308b <\/li><li>\u6b63\u3057\u3044\u53d6\u308a\u4ed8\u3051\u4f4d\u7f6e\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30d4\u30fc\u30af\u306e\u5206\u88c2<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-05.jpg\" alt=\"Split peaks\" width=\"200\" height=\"193\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u6eb6\u5a92\uff0f\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u304c\u5408\u3063\u3066\u3044\u306a\u3044<\/td><td><ul><li>\u6eb6\u5a92\u3084\u56fa\u5b9a\u76f8\u3092\u8abf\u6574\u3057\u3066\u6e7f\u6f64\u3092\u53ef\u80fd\u306b\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u4e0d\u5b8c\u5168\u306a\u6c17\u5316<\/td><td><ul><li>\u6c17\u5316\u3092\u4fc3\u9032\u3055\u305b\u308b\u305f\u3081\u306b\u3001\u30a6\u30fc\u30eb\u5165\u308a\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u306a\u3069\u3067\u8868\u9762\u7a4d\u3092\u8ffd\u52a0\u3059\u308b <\/li><li>\u9069\u5207\u306a\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u6e29\u5ea6\u3092\u4f7f\u7528\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u304c\u8d85\u904e<\/td><td><ul><li>\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059\uff08\u5e0c\u91c8\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306e\u4f7f\u7528\u3001\u6ce8\u5165\u91cf\u306e\u524a\u6e1b\uff09<\/li><\/ul><\/td><\/tr><tr><td>\u9ad8\u901f\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u306b\u3088\u308a\u30aa\u30fc\u30d7\u30f3\u30e9\u30a4\u30ca\u30fc\u3078\u306e\u6ce8\u5165<\/td><td><ul><li>\u30a6\u30fc\u30eb\u3084\u9045\u3044\u6ce8\u5165\u901f\u5ea6\u3092\u4f7f\u7528\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\uff0f\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"4\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-06.jpg\" alt=\"Carryover\/ghost peaks\" width=\"200\" height=\"377\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u6c5a\u67d3\u3055\u308c\u305f\u30b7\u30ea\u30f3\u30b8\u307e\u305f\u306f\u6d17\u6d44\u6eb6\u5a92<\/td><td><ul><li>\u6d17\u6d44\u6eb6\u5a92\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30b7\u30ea\u30f3\u30b8\u3092\u6d17\u6d44\u307e\u305f\u306f\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\uff08\u30b5\u30f3\u30d7\u30eb\u91cf\u304c\u30e9\u30a4\u30ca\u30fc\u91cf\u3092\u8d85\u3048\u308b\uff09<\/td><td><ul><li>\u6ce8\u5165\u91cf\u3092\u6e1b\u3089\u3059 <\/li><li>\u5185\u5f84\u306e\u5927\u304d\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b <\/li><li>\u30d8\u30c3\u30c9\u5727\uff08\u3059\u306a\u308f\u3061\u6d41\u91cf\uff09\u3092\u4e0a\u3052\u3066\u84b8\u6c17\u96f2\u3092\u6291\u5236\u3059\u308b <\/li><li>\u6ce8\u5165\u901f\u5ea6\u3092\u9045\u304f\u3059\u308b <\/li><li>\u30a4\u30f3\u30ec\u30c3\u30c8\u6e29\u5ea6\u3092\u4e0b\u3052\u308b <\/li><li>\u30b9\u30d7\u30ea\u30c3\u30c8\u30d5\u30ed\u30fc\u3092\u5897\u3084\u3059 <\/li><li>\u30d1\u30c3\u30ad\u30f3\u4ed8\u304d\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b <\/li><li>\u5727\u529b\u30d1\u30eb\u30b9\u6ce8\u5165\u3092\u4f7f\u7528\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u524d\u56de\u306e\u5206\u6790\u7d42\u4e86\u304c\u65e9\u3059\u304e\u305f<\/td><td><ul><li>\u3059\u3079\u3066\u306e\u6210\u5206\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u30de\u30c8\u30ea\u30af\u30b9\u7531\u6765\u306e\u593e\u96d1\u7269\u304c\u6eb6\u51fa\u3059\u308b\u307e\u3067\u5206\u6790\u6642\u9593\u3092\u5ef6\u9577\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u9ad8\u30d6\u30ea\u30fc\u30c9<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"4\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-07.jpg\" alt=\"High bleed\" width=\"200\" height=\"133\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u4e0d\u9069\u5207\u306a\u30ab\u30e9\u30e0\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0<\/td><td><ul><li>\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u6642\u9593\u3092\u5897\u3084\u3059\u3001\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u6e29\u5ea6\u3092\u4e0a\u3052\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u6c5a\u67d3<\/td><td><ul><li>\u30ab\u30e9\u30e0\u3092\u30c8\u30ea\u30df\u30f3\u30b0\u3059\u308b\u3001\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u6700\u9ad8\u6e29\u5ea6\u307e\u3067\u52a0\u71b1\u3057\u3066\u3001\u6c5a\u67d3\u7269\u8cea\u3092\u53d6\u308a\u9664\u304f <\/li><li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u30d5\u30a3\u30eb\u30bf\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u691c\u51fa\u5668\u30ac\u30b9\u30d5\u30a3\u30eb\u30bf\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u304a\u3088\u3073\u691c\u51fa\u5668\u3092\u6383\u9664\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b7\u30b9\u30c6\u30e0\u306e\u6f0f\u308c\u3068\u56fa\u5b9a\u76f8\u306e\u9178\u5316<\/td><td><ul><li>\u30b7\u30b9\u30c6\u30e0\u5168\u4f53\u3067\u9178\u7d20\u306e\u6f0f\u308c\u3092\u78ba\u8a8d\u3057\u3001\u30b7\u30fc\u30eb\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u30d5\u30a3\u30eb\u30bf\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30ab\u30e9\u30e0\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u4e0d\u5b89\u5b9a\u306a\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\uff08\u30b9\u30d1\u30a4\u30af\u3001\u30ce\u30a4\u30ba\u3001\u30c9\u30ea\u30d5\u30c8\uff09<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"8\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-08.jpg\" alt=\"Unstable baseline\" width=\"1000\" height=\"2017\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6f0f\u308c\u307e\u305f\u306f\u6c5a\u67d3<\/td><td><ul><li>\u63a5\u7d9a\u90e8\u5206\u306b\u6f0f\u308c\u304c\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u30b7\u30fc\u30eb\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u30d5\u30a3\u30eb\u30bf\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u691c\u51fa\u5668\u30ac\u30b9\u30d5\u30a3\u30eb\u30bf\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u307e\u305f\u306f\u691c\u51fa\u5668\u306e\u6c5a\u67d3<\/td><td><ul><li>\u30b7\u30b9\u30c6\u30e0\u3092\u6e05\u6383\u3057\u3001\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u306e\u6c5a\u67d3\u307e\u305f\u306f\u56fa\u5b9a\u76f8\u306e\u30d6\u30ea\u30fc\u30c9<\/td><td><ul><li>\u30ab\u30e9\u30e0\u3092\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3001\u30c8\u30ea\u30df\u30f3\u30b0\u3001\u6d17\u6d44\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30bb\u30d7\u30bf\u30e0\u30b3\u30a2\u30ea\u30f3\u30b0\uff0f\u30d6\u30ea\u30fc\u30c9<\/td><td><ul><li>\u30bb\u30d7\u30bf\u30e0\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30a4\u30f3\u30ec\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u306b\u30bb\u30d7\u30bf\u30e0\u306e\u7c92\u5b50\u304c\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u30e9\u30a4\u30ca\u30fc\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b1\u30fc\u30d6\u30eb\u3084\u56de\u8def\u57fa\u677f\u306e\u63a5\u7d9a\u90e8\u5206\u304c\u7de9\u3093\u3067\u3044\u308b<\/td><td><ul><li>\u96fb\u6c17\u63a5\u7d9a\u90e8\u5206\u3092\u6e05\u6383\u304a\u3088\u3073\u4fee\u7406\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u30d5\u30ed\u30fc\u307e\u305f\u306f\u691c\u51fa\u5668\u30ac\u30b9\u30d5\u30ed\u30fc\u304c\u4e0d\u5b89\u5b9a<\/td><td><ul><li>\u6d41\u91cf\u304c\u5b89\u5b9a\u3057\u3066\u518d\u73fe\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b\uff1b\u30d5\u30ed\u30fc\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u3092\u4ea4\u63db\u307e\u305f\u306f\u4fee\u7406\u306e\u53ef\u80fd\u6027\u3082\u3042\u308a <\/li><li>\u30b7\u30b9\u30c6\u30e0\u306e\u6f0f\u308c\u304c\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u691c\u51fa\u5668\u304c\u6e96\u5099\u3067\u304d\u3066\u3044\u306a\u3044<\/td><td><ul><li>\u691c\u51fa\u5668\u306e\u6e29\u5ea6\u3068\u30d5\u30ed\u30fc\u304c\u5b89\u5b9a\u3059\u308b\u306e\u306b\u5341\u5206\u306a\u6642\u9593\u3092\u78ba\u4fdd\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u3070\u3089\u3064\u304d<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"9\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-09.jpg\" alt=\"Response variation\" width=\"200\" height=\"238\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u306e\u554f\u984c<\/td><td><ul><li>\u30b5\u30f3\u30d7\u30eb\u6e29\u5ea6\u3092\u78ba\u8a8d\u3059\u308b <\/li><li>\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u88fd\u624b\u9806\u3092\u78ba\u8a8d\u3059\u308b <\/li><li>\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u89e3\uff0f\u4fdd\u5b58\u671f\u9593\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b7\u30ea\u30f3\u30b8\u306e\u554f\u984c<\/td><td><ul><li>\u30b7\u30ea\u30f3\u30b8\u3092\u4ea4\u63db\u3059\u308b <\/li><li>\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u306e\u52d5\u4f5c\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u96fb\u6c17\u7cfb\u7d71\u306e\u554f\u984c<\/td><td><ul><li>\u30b7\u30b0\u30ca\u30eb\u8a2d\u5b9a\u3092\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u8abf\u6574\u3059\u308b <\/li><li>\u30b1\u30fc\u30d6\u30eb\u3084\u57fa\u677f\u3092\u4fee\u7406\u307e\u305f\u306f\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u6c5a\u308c\u3084\u640d\u50b7\u306e\u3042\u308b\u691c\u51fa\u5668<\/td><td><ul><li>\u691c\u51fa\u5668\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u5b9f\u65bd\u3059\u308b\u304b\u90e8\u54c1\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30d5\u30ed\u30fc\uff0f\u6e29\u5ea6\u8a2d\u5b9a\u304c\u8aa4\u3063\u3066\u3044\u308b\u304b\u5909\u52d5\u3057\u3066\u3044\u308b<\/td><td><ul><li>\u6d41\u91cf\u3068\u6e29\u5ea6\u306e\u5b89\u5b9a\u6027\u3092\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u8a2d\u5b9a\u3092\u8abf\u6574\u3059\u308b\u3001\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u90e8\u54c1\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u5438\u7740\uff0f\u53cd\u5fdc\u6027<\/td><td><ul><li>\u6c5a\u67d3\u7269\u8cea\u3092\u53d6\u308a\u9664\u304d\u3001\u9069\u5207\u306b\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u90e8\u54c1\u3092\u4f7f\u7528\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u6f0f\u308c<\/td><td><ul><li>\u5168\u3066\u306e\u63a5\u7d9a\u90e8\u5206\u3067\u6f0f\u308c\u304c\u306a\u3044\u304b\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u306e\u5c0e\u5165\uff0f\u6ce8\u5165\u65b9\u6cd5\u306e\u5909\u66f4<\/td><td><ul><li>\u6ce8\u5165\u6280\u8853\u3092\u78ba\u8a8d\u3057\u3001\u5143\u306e\u6280\u6cd5\u306b\u623b\u3059 <\/li><li>\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u304c\u6b63\u3057\u3044\u304b\u78ba\u8a8d\u3059\u308b <\/li><li>\u30d1\u30fc\u30b8\u6642\u9593\u307e\u305f\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30db\u30fc\u30eb\u30c9\u30bf\u30a4\u30e0\u304c\u6b63\u3057\u3044\u304b\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30d4\u30fc\u30af\u306a\u3057<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"5\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-10.jpg\" alt=\"No peaks\" width=\"1000\" height=\"233\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u6ce8\u5165\u306e\u554f\u984c<\/td><td><ul><li>\u8a70\u307e\u3063\u305f\u30b7\u30ea\u30f3\u30b8\uff1b\u30b7\u30ea\u30f3\u30b8\u3092\u6e05\u6383\u307e\u305f\u306f\u4ea4\u63db\u3059\u308b <\/li><li>\u30b5\u30f3\u30d7\u30eb\u304c\u306a\u3044\uff1b\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u3055\u308c\u3066\u3044\u308b\u304b\u78ba\u8a8d\u3059\u308b <\/li><li>\u9593\u9055\u3063\u305f\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306b\u6ce8\u5165\u3057\u3066\u3044\u308b\uff1b\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u3092\u30ea\u30bb\u30c3\u30c8\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u58ca\u308c\u305f\u30ab\u30e9\u30e0<\/td><td><ul><li>\u30ab\u30e9\u30e0\u3092\u4ea4\u63db\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u304c\u3001\u9593\u9055\u3063\u305f\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u307e\u305f\u306f\u691c\u51fa\u5668\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066\u3044\u308b<\/td><td><ul><li>\u30ab\u30e9\u30e0\u3092\u518d\u53d6\u308a\u4ed8\u3051\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u691c\u51fa\u5668\u306e\u554f\u984c<\/td><td><ul><li>\u30b7\u30b0\u30ca\u30eb\u304c\u8a18\u9332\u3055\u308c\u3066\u3044\u306a\u3044\uff1b\u691c\u51fa\u5668\u306e\u30b1\u30fc\u30d6\u30eb\u3092\u78ba\u8a8d\u3057\u3001\u691c\u51fa\u5668\u304c\u30aa\u30f3\u306b\u306a\u3063\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b <\/li><li>\u691c\u51fa\u5668\u30ac\u30b9\u304c\u30aa\u30d5\u306b\u306a\u3063\u3066\u3044\u308b\u304b\u3001\u6d41\u91cf\u304c\u9055\u3046\uff1b\u691c\u51fa\u5668\u3092\u30aa\u30f3\u306b\u3059\u308b\u3001\u304a\u3088\u3073\uff0f\u307e\u305f\u306f\u6d41\u91cf\u3092\u8abf\u6574\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u25a0 \u30d4\u30fc\u30af\u304c\u5e83\u304c\u308b<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td rowspan=\"7\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1724A-chart-11.jpg\" alt=\"Broad peaks\" width=\"1000\" height=\"1700\" title=\"-\"><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u89e3\u6c7a\u7b56<\/strong><\/td><\/tr><tr><td>\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u304c\u5927\u304d\u3044<\/td><td><ul><li>GC\u30b7\u30b9\u30c6\u30e0\u306e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u9069\u5207\u306a\u30ab\u30e9\u30e0\u306e\u53d6\u308a\u4ed8\u3051\u3001\u9069\u5207\u306a\u30b3\u30cd\u30af\u30bf\u3001\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u306a\u3069\u3092\u78ba\u8a8d\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u6d41\u91cf\u304c\u4f4e\u3044<\/td><td><ul><li>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u6d41\u91cf\u3092\u78ba\u8a8d\u3057\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u8abf\u6574\u3059\u308b <\/li><li>\u30e1\u30a4\u30af\u30a2\u30c3\u30d7\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u78ba\u8a8d\u3057\u3066\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u8abf\u6574\u3059\u308b<\/li><\/ul><\/td><\/tr><tr><td>GC\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u9045\u3044<\/td><td><ul><li>GC\u30aa\u30fc\u30d6\u30f3\u306e\u30d7\u30ed\u30b0\u30e9\u30df\u30f3\u30b0\u30ec\u30fc\u30c8\u3092\u5897\u52a0\u3055\u305b\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u5206\u6790\u5bfe\u8c61\u6210\u5206\uff0f\u6eb6\u5264\u306e\u30d5\u30a9\u30fc\u30ab\u30b7\u30f3\u30b0\u4e0d\u826f<\/td><td><ul><li>GC\u30aa\u30fc\u30d6\u30f3\u306e\u958b\u59cb\u6e29\u5ea6\u3092\u4e0b\u3052\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u306e\u819c\u539a\u304c\u539a\u3059\u304e\u308b<\/td><td><ul><li>\u819c\u539a\u3068\u9577\u3055\u3092\u6e1b\u5c11\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u5316\u5408\u7269\u306e\u4fdd\u6301\u3092\u6e1b\u5c11\u3055\u305b\u308b<\/li><\/ul><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb\u306e\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc<\/td><td><ul><li>\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\uff0f\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u306e\u89e3\u6c7a\u7b56\u306e\u6b04\u3092\u53c2\u7167\u3059\u308b<\/li><\/ul><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Pro <em>EZ<\/em>GC Chromatogram Modeler\u3067\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u524d\u9032\u3055\u305b\u307e\u3057\u3087\u3046<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9a\u8a55\u306e\u3042\u308bRestek Pro <em>EZ<\/em>GC Chromatogram Modeler \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306e\u6539\u826f\u7248\u306f\u3001\u4eca\u307e\u3067\u306e\u4f7f\u3044\u3084\u3059\u3055\u3092\u7dad\u6301\u3057\u3064\u3064\u3001\u56fa\u5b9a\u76f8\u306e\u9078\u629e\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304a\u3088\u3073\u5236\u5fa1\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u5909\u66f4\u306a\u3069\u306e\u9ad8\u5ea6\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u3088\u3063\u3066\u3001\u5f93\u6765\u3088\u308a\u3082\u52b9\u7387\u7684\u304b\u3064\u52b9\u679c\u7684\u306a\u3001\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3084\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u9069\u5316\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3059\u3067\u306b\u4e16\u754c\u4e2d\u306e\u5206\u6790\u8005\u306b\u611b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u30a2\u30c3\u30d7\u30c7\u30fc\u30c8\u7248\u306f\u3001\u4eca\u307e\u3067\u4ee5\u4e0a\u306b\u52b9\u7387\u7684\u306b\u4f5c\u696d\u3092\u9032\u3081\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u540c\u7b49\u306e\u3001\u975e\u5e38\u306b\u7cbe\u5ea6\u306e\u9ad8\u3044\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u751f\u6210\u3059\u308b\u306e\u306b\u6642\u9593\u3092\u53d6\u308a\u307e\u305b\u3093\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u62e1\u5927\u3084\u5316\u5b66\u69cb\u9020\u306e\u78ba\u8a8d\u3001\u3055\u3089\u306b\u306f\u5171\u6eb6\u51fa\u5316\u5408\u7269\u306e\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3092\u91cd\u306d\u3066\u8868\u793a\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"751\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-modeler-JP-1024x751.jpg\" alt=\"\" class=\"wp-image-24519\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-modeler-JP-1024x751.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-modeler-JP-300x220.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-modeler-JP-768x563.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-modeler-JP.jpg 1332w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\">Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3069\u3093\u306a\u3068\u304d\u306b\u4f7f\u3046\uff1f:<\/strong>&nbsp;\u30ab\u30e9\u30e0\u306e\u9078\u5b9a\u542b\u3081\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u30bc\u30ed\u304b\u3089\u958b\u767a\u3059\u308b\u3068\u304d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u306a\u306b\u3092\u6e96\u5099\u3059\u308c\u3070\u3088\u3044\uff1f:<\/strong>&nbsp;\u5206\u6790\u5bfe\u8c61\u6210\u5206\u30ea\u30b9\u30c8\uff08\u30ab\u30e9\u30e0\u6307\u5b9a\u3082\u53ef\uff09\u304c\u3042\u308c\u3070OK\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6700\u7d42\u6210\u679c\u7269\u306f\u306a\u306b\uff1f:<\/strong>&nbsp;\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u53ef\u80fd\u306a\u3001\u30a4\u30f3\u30bf\u30e9\u30af\u30c6\u30a3\u30d6\u306a\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u7279\u5b9a\u306e\u56fa\u5b9a\u76f8\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3001\u304a\u3088\u3073\u6761\u4ef6\u3082\u4e00\u7dd2\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u30ab\u30e9\u30e0\u5909\u66f4\u3001\u6761\u4ef6\u306e\u8abf\u6574\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u62e1\u5927\u3084\u5316\u5b66\u69cb\u9020\u306e\u78ba\u8a8d\u3001\u3055\u3089\u306b\u306f\u5171\u6eb6\u51fa\u5316\u5408\u7269\u306e\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3092\u91cd\u306d\u3066\u8868\u793a\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u4f7f\u7528\u65b9\u6cd5\u306b\u95a2\u3059\u308b\u52d5\u753b\u3082\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002\u4eca\u3059\u3050\u4f7f\u3063\u3066\u307f\u307e\u305b\u3093\u304b\uff1f&nbsp;<a href=\"https:\/\/ez.restek.com\/proezgc\/en\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/proezgc<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>EZ<\/em>GC Method Translator\u304a\u3088\u3073Flow Calculator\u3092\u4f7f\u7528\u3057\u3066\u30e1\u30bd\u30c3\u30c9\u3092\u8fc5\u901f\u304b\u3064\u78ba\u5b9f\u306b\u5909\u66f4<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>EZ<\/em>GC Method Translator\u3068<em>EZ<\/em>GC Flow Calculator\u3092\u4f7f\u3048\u3070\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3084\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5909\u66f4\u3001\u307e\u305f\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u30b9\u30d4\u30fc\u30c9\u3084\u52b9\u7387\u306e\u6700\u9069\u5316\u3092\u30b7\u30f3\u30d7\u30eb\u306a\u624b\u9806\u3067\u884c\u3048\u307e\u3059\u3002\u30e1\u30bd\u30c3\u30c9\u306e\u4ed5\u69d8\u3092\u5165\u529b\u3057\u3055\u3048\u3059\u308c\u3070\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3088\u3063\u3066\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u304c\u8a08\u7b97\u3055\u308c\u3001\u540c\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<em>EZ<\/em>GC Method Translator\u3068<em>EZ<\/em>GC Flow Calculator\u3092\u6d3b\u7528\u3057\u3066\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\uff01<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"635\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-translator-and-calculator-JP-1024x635.jpg\" alt=\"\" class=\"wp-image-24525\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-translator-and-calculator-JP-1024x635.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-translator-and-calculator-JP-300x186.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-translator-and-calculator-JP-768x476.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/GNAR1724C-chromatogram-translator-and-calculator-JP.jpg 1362w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading\"><em>EZ<\/em>GC Method Translator and Flow Calculator<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u3069\u3093\u306a\u3068\u304d\u306b\u4f7f\u3046\uff1f:<\/strong>&nbsp;\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u5207\u308a\u66ff\u3048\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\uff0f\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5909\u66f4\u3001\u307e\u305f\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u30b9\u30d4\u30fc\u30c9\uff0f\u52b9\u7387\u306e\u6700\u9069\u5316\u304c\u5fc5\u8981\u306a\u3068\u304d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u306a\u306b\u3092\u6e96\u5099\u3059\u308c\u3070\u826f\u3044\uff1f:<\/strong>&nbsp;\u65e2\u5b58\u306e\u30e1\u30bd\u30c3\u30c9\u60c5\u5831\u304c\u3042\u308c\u3070OK\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6700\u7d42\u6210\u679c\u7269\u306f\u306a\u306b\uff1f:<\/strong>&nbsp;\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u3068\u540c\u7b49\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u5b9f\u73fe\u3059\u308bGC\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3001\u5206\u6790\u6642\u9593\u3001\u5e73\u5747\u7dda\u901f\u5ea6\u3001\u6d41\u91cf\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6642\u9593\u3001\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u3059\u3079\u3066\u304c\u4f7f\u3044\u3084\u3059\u3044\u30b7\u30f3\u30b0\u30eb\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3067\u63d0\u4f9b\u3055\u308c\u3001\u30c4\u30fc\u30eb\u9593\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u5207\u308a\u66ff\u3048\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Restek\u306eEZGC\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb\u304c\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3001\u6700\u9069\u5316\u306e\u6642\u9593\u7bc0\u7d04\u3092\u304a\u624b\u4f1d\u3044\u3057\u307e\u3059\uff01&nbsp;<a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/ezgc-mtfc<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#section_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6b63\u3057\u3044GC\u30ab\u30e9\u30e0\u3092\u9078\u3076\u65b9\u6cd5\u3092\u5b66\u3076\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002  \u5206\u96e2\u3068\u901f\u5ea6\u306e\u30d9\u30b9\u30c8\u30d0\u30e9\u30f3\u30b9\u306e\u305f\u3081\u306b\u6700\u9069\u5316\u3092\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u75c7\u72b6\u306b\u57fa\u3065\u3044\u3066\u8fc5\u901f\u304b\u3064\u52b9\u679c\u7684\u306b\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7093,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[2802],"product-library":[2564,2564,2552],"resource-technique":[2340],"ppma_author":[2814,414],"class_list":["post-45321","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","resource-type-selection-guides","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"resource-type":[{"value":2802,"label":"Selection Guides"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR1724-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":507,"filter":"raw","cat_ID":789,"category_count":507,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45321","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45321"}],"version-history":[{"count":42,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45321\/revisions"}],"predecessor-version":[{"id":92222,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45321\/revisions\/92222"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7093"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45321"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45321"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45321"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45321"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45321"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45321"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45321"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45321"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45321"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}