{"id":45322,"date":"2020-10-29T00:00:00","date_gmt":"2020-10-29T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-how-to-choose-a-gc-inlet-liner\/"},"modified":"2026-06-22T07:10:07","modified_gmt":"2026-06-22T07:10:07","slug":"japanese-how-to-choose-a-gc-inlet-liner","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar1991-ja\/japanese-how-to-choose-a-gc-inlet-liner","title":{"rendered":"GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9: \u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u7c21\u5358\u306a\u30bb\u30ec\u30af\u30b7\u30e7\u30f3\u30ac\u30a4\u30c9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u591a\u304f\u306e\u7a2e\u985e\u304c\u3042\u308a\u305d\u308c\u305e\u308c\u304c\u7570\u306a\u308b\u7279\u6027\u3092\u6301\u3063\u3066\u3044\u307e\u3059\uff08\u5f62\u72b6\u30c7\u30b6\u30a4\u30f3\u3001\u5bb9\u91cf\u3001\u5185\u5f84\u3001\u4e0d\u6d3b\u6027\u51e6\u7406\u3001\u7279\u5b9a\u306e\u5145\u586b\u7269\u306e\u6709\u7121\u7b49\uff09\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u5206\u6790\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u3076\u3053\u3068\u306f\u7c21\u5358\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u6ce8\u5165\u65b9\u6cd5\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u30e9\u30a4\u30ca\u30fc\u9078\u5b9a\u306f\u7c21\u5358\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u3044\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306e\u3042\u308b\u5b89\u5b9a\u3057\u305f\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306e\u30e9\u30a4\u30ca\u30fc\u9078\u5b9a\u3092\u6ce8\u5165\u65b9\u6cd5\u5225\u306b\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u307e\u305a\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u306f\u3001Restek\u306e\u30a6\u30fc\u30eb\u5165\u308aTopaz Precision\u30e9\u30a4\u30ca\u30fc\u304c\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u306f\u3001Restek\u306e\u30a6\u30fc\u30eb\u5165\u308aTopaz\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u9069\u3057\u3066\u3044\u308b\u3068\u8a00\u3048\u307e\u3059\u3002\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u306b\u95a2\u3057\u3066\u306f\u3001\u30c9\u30ea\u30eb\u52a0\u5de5\u3057\u305f\uff08\u30db\u30fc\u30eb\u304c\u958b\u3044\u305f\uff09\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4e0a\u90e8\u306b\u30db\u30fc\u30eb\u3092\u5099\u3048\u305f\u30e9\u30a4\u30ca\u30fc\u304c\u52b9\u679c\u7684\u3067\u3059\u3002\u4e00\u65b9\u3001\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u5834\u5408\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5f84\u3092\u7d30\u304f\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30d0\u30f3\u30c9\u3092\u30bf\u30a4\u30c8\u306b\u4fdd\u3061\u3001\u5206\u96e2\u52b9\u7387\u3092\u9ad8\u3081\u308b\u305f\u3081\u3067\u3059\u3002PTV\u6ce8\u5165\u306e\u5834\u5408\u3067\u3082\u3001\u6ce8\u5165\u53e3\u306b\u9069\u5408\u3057\u305f\u3001\u5185\u5f84\u306e\u5c0f\u3055\u3044\u30e9\u30a4\u30ca\u30fc\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u30d0\u30c3\u30d5\u30eb\u3084\u30c7\u30a3\u30f3\u30d7\u30eb\u4ed8\u304d\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6ce8\u5165\u306e\u5747\u4e00\u6027\u3068\u7cbe\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"table_of_contents\">\u4e0a\u8a18\u306f\u4e00\u822c\u7684\u306a\u6307\u91dd\u3068\u3057\u3066\u975e\u5e38\u306b\u6709\u52b9\u3067\u3059\u304c\u3001\u5b9f\u969b\u306e\u5206\u6790\u3067\u306f\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u7279\u6027\u306b\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u30e9\u30a4\u30ca\u30fc\u3092\u6c7a\u3081\u308b\u3079\u304d\u3067\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u30e9\u30a4\u30ca\u30fc\u9078\u5b9a\u3092\u884c\u3046\u969b\u306b\u3001\u5229\u7528\u53ef\u80fd\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u5341\u5206\u306b\u7406\u89e3\u3057\u3001\u305d\u308c\u304c\u3054\u81ea\u8eab\u306e\u5206\u6790\u306b\u3069\u306e\u3088\u3046\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3092\u628a\u63e1\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306b\u5404\u7279\u6027\u306e\u5229\u70b9\u3084\u6ce8\u5165\u65b9\u6cd5\u306e\u7279\u5fb4\u306b\u3064\u3044\u3066\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30e9\u30a4\u30ca\u30fc\u9078\u5b9a\u306b\u305c\u3072\u3054\u6d3b\u7528\u4e0b\u3055\u3044\uff01<\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color has-medium-font-size wp-elements-1 wp-block-paragraph\" id=\"table-of-content\"><strong>\u3010\u76ee\u6b21\u3011<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list has-theme-palette-7-background-color has-background\">\n<li><a href=\"#mokuji1\">\u5f62\u72b6<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#mokuji11\">\u6c17\u5316\u4fc3\u9032<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji12\">\u30b5\u30f3\u30d7\u30eb\u4fdd\u8b77<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#mokuji2\">\u5bb9\u91cf\u3068\u5185\u5f84<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#mokuji21\">\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u4f53\u7a4d<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji22\">\u7dda\u901f\u5ea6<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#mokuji3\">\u4e0d\u6d3b\u6027\u51e6\u7406<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list has-theme-palette-7-background-color has-background\">\n<li><a href=\"#mokuji4\">\u5145\u586b\u7269<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#mokuji41\">\u5145\u586b\u5264\u3068\u5145\u586b\u4f4d\u7f6e<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji42\">\u4ee3\u66ff\u30a6\u30fc\u30eb<\/a><\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#mokuji5\">\u6ce8\u5165\u65b9\u6cd5<\/a>\n<ul class=\"wp-block-list\">\n<li><a href=\"#mokuji51\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji52\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji53\">\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji54\">\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u6ce8\u5165\u306b\u3088\u308b\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji55\">\u6607\u6e29\u6c17\u5316\uff08PTV\uff09\u6ce8\u5165<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list has-theme-palette-7-background-color has-background\">\n<li><a href=\"#mokuji6\">\u30e9\u30a4\u30ca\u30fc\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji7\">Restek Topaz GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji1\">\u5f62\u72b6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u3082\u30b7\u30f3\u30d7\u30eb\u306aGC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u5145\u586b\u7269\u306e\u6709\u7121\u306b\u95a2\u308f\u3089\u305a\u3001\u57fa\u672c\u7684\u306b\u30b9\u30c8\u30ec\u30fc\u30c8\u306e\u30c1\u30e5\u30fc\u30d6\u5f62\u72b6\u3092\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5b9f\u969b\u306b\u306f\u7279\u6b8a\u306a\u5f62\u72b6\u3067\u8a2d\u8a08\u3055\u308c\u305f\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u304c\u6570\u591a\u304f\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306e\u5f62\u72b6\u306f\u4e3b\u306b\u3001\u52b9\u7387\u7684\u306a\u6c17\u5316\u4fc3\u9032\u3068\u3001\uff08\u7279\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6642\u306e\uff09\u9069\u5207\u306a\u30b5\u30f3\u30d7\u30eb\u4fdd\u8b77\u3092\u76ee\u7684\u3068\u3057\u3066\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-2\" id=\"mokuji11\" style=\"font-size:22px\">\u6c17\u5316\u4fc3\u9032<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u3068\u4f4e\u6cb8\u70b9\u5316\u5408\u7269\u3001\u307e\u305f\u306f\u975e\u6975\u6027\u6210\u5206\u3068\u6975\u6027\u5206\u6790\u5bfe\u8c61\u7269\u9593\u3067\u306e\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\uff08\u8a66\u6599\u306e\u7d44\u6210\u5909\u5316\u304c\u767a\u751f\u3059\u308b\u3053\u3068\uff09\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u306f\u3001\u6c17\u5316\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u3092\u5b9f\u73fe\u3059\u308b\u306e\u304c\u3001\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u304c\u5145\u586b\u3055\u308c\u305f\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3067\u3059\uff08<strong>Figure 1<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Restek Topaz Precision liner with wool (\u30a6\u30fc\u30eb\u5165\u308aPrecision\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23305)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23305.jpg\" alt=\"figure-article-GNAR1991C-23305.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-3\" id=\"mokuji12\" style=\"font-size:22px\">\u30b5\u30f3\u30d7\u30eb\u4fdd\u8b77<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u9ad8\u6e29\u306e\u91d1\u5c5e\u8868\u9762\u3068\u63a5\u89e6\u3059\u308b\u3068\u3001\u6ce8\u5165\u53e3\u5185\u90e8\u3067\u30b5\u30f3\u30d7\u30eb\u304c\u52a3\u5316\u3057\u3084\u3059\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u3001\u6ce8\u5165\u53e3\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u63a5\u89e6\u3092\u6700\u5c0f\u5316\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u3092\u5b9f\u73fe\u3059\u308b\u306e\u304c\u3001\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30c6\u30fc\u30d1\u5f62\u72b6\u3092\u6301\u3064\u30e9\u30a4\u30ca\u30fc\u3067\u3059\uff08<strong>Figure 2<\/strong>\uff5e<strong>Figure 5<\/strong>\uff09\u3002\u30c6\u30fc\u30d1\u5f62\u72b6\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u5185\u306b\u9577\u6642\u9593\u7559\u307e\u308b\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6642\u306b\u7279\u306b\u52b9\u679c\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Restek Topaz single taper liner\uff08\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23302)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23302.jpg\" alt=\"figure-article-GNAR1991C-23302.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23302\">                                \u30ab\u30bf\u30ed\u30b0No. 23302                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23302\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Restek Topaz double taper liner\uff08\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23308)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23308.jpg\" alt=\"figure-article-GNAR1991C-23308.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23308\">                                \u30ab\u30bf\u30ed\u30b0No. 23308                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Double Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23308\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u9069\u5207\u306b\u4fdd\u8b77\u3057\u306a\u304c\u3089\u6c17\u5316\u3092\u52b9\u7387\u7684\u306b\u4fc3\u9032\u3059\u308b\u6a5f\u80fd\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u30e9\u30a4\u30ca\u30fc\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><br><strong>Figure 4:<\/strong> Restek Topaz single taper liner with wool\uff08\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23303)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"101\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1024x101.jpg\" alt=\"\" class=\"wp-image-20583\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1024x101.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-300x30.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-768x76.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1536x151.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> Restek Topaz cyclo double taper liner\uff08\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23310)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23310.jpg\" alt=\"figure-article-GNAR1991C-23310.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">                                \u30ab\u30bf\u30ed\u30b0No. 23310                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Cyclo Double Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji2\">\u5bb9\u91cf\u3068\u5185\u5f84<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u4f53\u7a4d\u3068\u7dda\u901f\u5ea6\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-4\" id=\"mokuji21\" style=\"font-size:22px\">\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u4f53\u7a4d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6db2\u4f53\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u6c17\u5316\u3059\u308b\u3068\u3001\u305d\u306e\u4f53\u7a4d\u306f\u5927\u5e45\u306b\u81a8\u5f35\u3057\u307e\u3059\u3002\u3053\u306e\u81a8\u5f35\u306b\u3088\u308a\u3001\u6ce8\u5165\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u304c\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u5360\u3081\u308b\u4f53\u7a4d\u304c\u5897\u52a0\u3057\u3001\u6700\u7d42\u7684\u306b\u30e9\u30a4\u30ca\u30fc\u306e\u6709\u52b9\u5bb9\u91cf\u3092\u8d85\u3048\u3066\u3057\u307e\u3046\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u81a8\u5f35\u3092\u9069\u5207\u306b\u7ba1\u7406\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u9069\u5207\u306b\u53ce\u5bb9\u3055\u308c\u308b\u3088\u3046\u306b\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u6ce8\u5165\u524d\u306b\u30b5\u30f3\u30d7\u30eb\u306e\u81a8\u5f35\u3092\u4e88\u6e2c\u3057\u3001\u4f7f\u7528\u3059\u308b\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u5b9a\u306b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u4e00\u822c\u7684\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u7269\u7406\u7684\u5bb9\u7a4d\u3068\u6709\u52b9\u5bb9\u91cf\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306f\u3001<strong>Table I<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u6eb6\u5a92\u6c17\u5316\u5bb9\u91cf\u30ab\u30ea\u30ad\u30e5\u30ec\u30fc\u30bf\u30fc\u3092\u4f7f\u7528\u3057\u3066\u81a8\u5f35\u306e\u5f71\u97ff\u3092\u4e8b\u524d\u306b\u8a08\u7b97\u3057\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5bb9\u91cf\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u305d\u306e\u8a08\u7b97\u7d50\u679c\u306e\u4f8b\u306b\u3064\u3044\u3066\u306f\u3001<strong>Table II<\/strong>\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u4e00\u822c\u7684\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u7269\u7406\u7684\u5bb9\u7a4d\u3068\u6709\u52b9\u5bb9\u91cf<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td>&nbsp;<\/td><td colspan=\"2\"><strong>\u304a\u304a\u3088\u305d\u306e\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf (\u03bcL)<\/strong><\/td><\/tr><tr><td><strong>\u30e9\u30a4\u30ca\u30fc\u540d<\/strong><\/td><td><strong>\u6ce8\u5165\u65b9\u6cd5<\/strong><\/td><td><strong>\u7269\u7406\u7684\u5bb9\u7a4d<\/strong><\/td><td><strong>\u6709\u52b9\u5bb9\u91cf*<\/strong><\/td><\/tr><tr><td>3 mm ID Intermediate-Volume Liner<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>520<\/td><td>260<\/td><\/tr><tr><td>3 mm ID Intermediate-Volume Liner for Shimadzu GCs<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>520<\/td><td>260<\/td><\/tr><tr><td>4 mm ID Straight Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>990<\/td><td>495<\/td><\/tr><tr><td>2 mm ID Straight Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>250<\/td><td>125<\/td><\/tr><tr><td>5 mm ID Straight Liner for Thermo TRACE GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>2060<\/td><td>1030<\/td><\/tr><tr><td>3.5 mm ID Straight Liner for Shimadzu 2010 GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>914<\/td><td>457<\/td><\/tr><tr><td>4 mm ID Single Taper Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>900<\/td><td>450<\/td><\/tr><tr><td>5 mm ID Single Taper Liner for Thermo TRACE GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>2000<\/td><td>1000<\/td><\/tr><tr><td>3.5 mm ID Single Taper Liner for Shimadzu 2010 GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>740<\/td><td>370<\/td><\/tr><tr><td>Double Taper Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>800<\/td><td>400<\/td><\/tr><tr><td>Cyclo Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>820<\/td><td>410<\/td><\/tr><tr><td>4 mm ID Low Pressure Drop Liner for Agilent GC<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9<\/td><td>850<\/td><td>425<\/td><\/tr><tr><td>1.5 mm ID Baffled Liner for Agilent GC<\/td><td>PTV<\/td><td>150<\/td><td>75<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">* \u6709\u52b9\u5bb9\u91cf\u306f\u3001\u7269\u7406\u7684\u5bb9\u7a4d\u306e\u7d041\/2\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u6eb6\u5a92\u6c17\u5316\u5bb9\u91cf\u30ab\u30ea\u30ad\u30e5\u30ec\u30fc\u30bf\u30fc\u306e\u7d50\u679c\u4f8b<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td colspan=\"2\"><strong>\u6eb6\u5a92\u6c17\u5316\u5bb9\u91cf\u4f8b<\/strong><\/td><\/tr><tr><td><strong>\u30d1\u30e9\u30e1\u30fc\u30bf<\/strong><\/td><td><strong>\u4f8b 1<\/strong><\/td><td><strong>\u4f8b 2<\/strong><\/td><\/tr><tr><td>\u6eb6\u5a92<\/td><td>\u30d8\u30ad\u30b5\u30f3<\/td><td>\u6c34<\/td><\/tr><tr><td>\u6ce8\u5165\u53e3\u5727\u529b (psi)<\/td><td>15.8<\/td><td>15.8<\/td><\/tr><tr><td>\u6ce8\u5165\u53e3\u6e29\u5ea6 (\u00b0C)<\/td><td>250<\/td><td>250<\/td><\/tr><tr><td>\u6c17\u5316\u5bb9\u91cf (\u03bcL)<\/td><td>159<\/td><td>1145<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d8\u30c3\u30c9\u5727 15.8 psi \u306e\u5834\u5408\u300140 \u00b0C \u306e\u30aa\u30fc\u30d6\u30f3\u5185\u306e 30 m\u3001\u5185\u5f84 0.25 mm \u306e\u30ab\u30e9\u30e0\u3067\u306f\u3001\u30ab\u30e9\u30e0\u30d5\u30ed\u30fc\u306f1.5 mL\/min\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-5\" id=\"mokuji22\" style=\"font-size:22px\">\u7dda\u901f\u5ea6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5185\u5f84\u306e\u7d30\u3044\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u3001\u6240\u5b9a\u306e\u6d41\u91cf\u306b\u5bfe\u3057\u3066\u7dda\u901f\u5ea6\u304c\u901f\u304f\u306a\u308a\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u901f\u5ea6\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u3053\u306e\u7d50\u679c\u3001\u6ce8\u5165\u30d0\u30f3\u30c9\u5e45\u304c\u72ed\u304f\u306a\u308a\u3001\u5206\u96e2\u52b9\u7387\u304c\u5411\u4e0a\u3059\u308b\u305f\u3081\u3001\u30d4\u30fc\u30af\u5e45\u3092\u72ed\u304f\u4fdd\u3064\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u7279\u306b\u3001\u63ee\u767a\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u3092\u5c0e\u5165\u3059\u308b\u30d1\u30fc\u30b8\uff06\u30c8\u30e9\u30c3\u30d7\u6cd5\u3084\u9759\u7684\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\u3001\u307e\u305f\u306f\u30ca\u30ed\u30fc\u30dc\u30a2\uff08\u5185\u5f840.18mm\u30010.15mm\u30010.10mm\uff09\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306b\u304a\u3044\u3066\u3001\u5185\u5f84\u306e\u7d30\u3044\u30e9\u30a4\u30ca\u30fc\u306f\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059\u3002\u5185\u5f84\u306e\u7d30\u3044\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u79fb\u52d5\u901f\u5ea6\u3092\u901f\u3081\u3001\u6ce8\u5165\u53e3\u5185\u3067\u306e\u6ede\u7559\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u3068\u3044\u3046\u5229\u70b9\u306b\u3088\u308a\u3001\u52b9\u7387\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u304c\u53ef\u80fd\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u5bb9\u91cf\u304c\u5c0f\u3055\u3044\u305f\u3081\u3001\u591a\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3059\u308b\u3068\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306e\u30ea\u30b9\u30af\u304c\u9ad8\u307e\u308b\u70b9\u306b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u4e00\u65b9\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306f\u305d\u306e\u5bb9\u91cf\u306e\u5927\u304d\u3055\u304b\u3089\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3067\u304d\u307e\u3059\u304c\u3001\u6d41\u901f\u304c\u4f4e\u3044\u305f\u3081\u3001\u6ce8\u5165\u53e3\u306b\u304a\u3051\u308b\u30d0\u30f3\u30c9\u30d6\u30ed\u30fc\u30c9\u30cb\u30f3\u30b0\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u5206\u89e3\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u3057\u3066\u3001\u4e2d\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff08\u4f8b\u3048\u3070\u3001cat.# 27231 and 27232\uff09\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3068\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u304a\u3044\u3066\u7279\u306b\u512a\u308c\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u52b9\u7387\u3068\u6027\u80fd\u306e\u30d0\u30e9\u30f3\u30b9\u3092\u4fdd\u3061\u306a\u304c\u3089\u3001\u3088\u308a\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u5206\u6790\u6027\u80fd\u3092\u640d\u306a\u3046\u3053\u3068\u306a\u304f\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u7d50\u679c\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27231\">                                \u30ab\u30bf\u30ed\u30b0No. 27231                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, \u4e2d\u5bb9\u91cf IV\u30e9\u30a4\u30ca\u30fc, \u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc, \u30a6\u30fc\u30eb\u5165\u308a, 3.0 mm x 6.5 x 78.5, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27231\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27232\">                                \u30ab\u30bf\u30ed\u30b0No. 27232                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, \u4e2d\u5bb9\u91cf IV\u30e9\u30a4\u30ca\u30fc, \u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc, \u30a6\u30fc\u30eb\u5165\u308a, 3.0 mm x 5 x 95, Shimadzu GC\u7528, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27232\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji3\">\u4e0d\u6d3b\u6027\u51e6\u7406<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30a4\u30ca\u30fc\u3068\u305d\u306e\u5145\u586b\u5264\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u5438\u7740\uff08\u53ef\u9006\u7684\u307e\u305f\u306f\u4e0d\u53ef\u9006\u7684\uff09\u3084\u5206\u89e3\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u6975\u3081\u3066\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044\u7d4c\u8def\u3092\u63d0\u4f9b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3044\u3066\u3001\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u4f4e\u4e0b\u3001\u30d4\u30fc\u30af\u306e\u6d88\u5931\u3084\u30c6\u30fc\u30ea\u30f3\u30b0\u3068\u3044\u3063\u305f\u554f\u984c\u306e\u591a\u304f\u306f\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u6d3b\u6027\u5ea6\u304c\u539f\u56e0\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u5f71\u97ff\u306f\u5b9a\u91cf\u5206\u6790\u3092\u8907\u96d1\u306b\u3057\u3001\u7279\u306b\u53cd\u5fdc\u6027\u304c\u9ad8\u3044\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u304a\u3044\u3066\u306f\u3001\u9855\u8457\u306a\u554f\u984c\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eTopaz\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u3053\u306e\u8ab2\u984c\u306b\u5bfe\u3059\u308b\u6700\u9069\u89e3\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002Topaz\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u6975\u3081\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6709\u3057\u3066\u304a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u6b63\u78ba\u306b\u30ab\u30e9\u30e0\u306b\u79fb\u52d5\u3055\u305b\u3001\u826f\u597d\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u3068\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001Topaz\u30e9\u30a4\u30ca\u30fc\u672c\u4f53\u304a\u3088\u3073\u5145\u586b\u3055\u308c\u3066\u3044\u308b\u30a6\u30fc\u30eb\u306b\u306f\u3001\u6700\u5148\u7aef\u306e\u4e0d\u6d3b\u6027\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u304a\u308a\u3001\u53cd\u5fdc\u6027\u304c\u9ad8\u304f\u76f8\u4e92\u4f5c\u7528\u3092\u8d77\u3053\u3057\u3084\u3059\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u3001\u4e0d\u6d3b\u6027\u306a\u72b6\u614b\u3092\u4fdd\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u300c\u5145\u586b\u5264\u3068\u5145\u586b\u4f4d\u7f6e\u300d\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306b\u3001\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u306f\u591a\u304f\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u3001\u7cbe\u5bc6\u3067\u6b63\u78ba\u306a\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u4e0d\u53ef\u6b20\u306a\u8981\u7d20\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u5f93\u6765\u306e\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u306f\u7269\u7406\u7684\u304a\u3088\u3073\u5316\u5b66\u7684\u306b\u6d3b\u6027\u90e8\u4f4d\u3068\u306a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u3068\u306e\u671b\u307e\u3057\u304f\u306a\u3044\u76f8\u4e92\u4f5c\u7528\u3092\u5f15\u304d\u8d77\u3053\u3059\u539f\u56e0\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u6d3b\u6027\u5ea6\u306b\u95a2\u3059\u308b\u61f8\u5ff5\u3092\u6392\u9664\u3057\u3001\u30a6\u30fc\u30eb\u304c\u63d0\u4f9b\u3059\u308b\u3059\u3079\u3066\u306e\u5229\u70b9\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u9ad8\u7d14\u5ea6\u3067\u6975\u3081\u3066\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044\u30a6\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eTopaz\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u30db\u30a6\u30b1\u30a4\u9178\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u3067\u306f\u306a\u304f\u3001\u306f\u308b\u304b\u306b\u7d14\u5ea6\u306e\u9ad8\u3044\u6eb6\u878d\u77f3\u82f1\u30a6\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u4e0d\u6d3b\u6027\u51e6\u7406\u3092\u65bd\u3057\u305f\u30a6\u30fc\u30eb\u3067\u3042\u3063\u3066\u3082\u3001\u5145\u586b\u307e\u3067\u306e\u53d6\u308a\u6271\u3044\u904e\u7a0b\u3067\u518d\u3073\u6d3b\u6027\u5316\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001Topaz\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3057\u305f\u5f8c\u306b\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\uff08in situ\u51e6\u7406\uff09\u3092\u65bd\u3059\u3053\u3068\u3067\u3001\u5353\u8d8a\u3057\u305f\u4e0d\u6d3b\u6027\u5ea6\u3068\u88fd\u54c1\u306e\u518d\u73fe\u6027\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji4\">\u5145\u586b\u7269<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30a4\u30ca\u30fc\u306e\u5145\u586b\u7269\u3068\u5145\u586b\u4f4d\u7f6e\u6c7a\u3081\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u306b\u304a\u3044\u3066\u975e\u5e38\u306b\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3068\u5747\u8cea\u5316\u304c\u6539\u5584\u3055\u308c\u3001\u4e0d\u63ee\u767a\u6027\u7269\u8cea\u304c\u30ab\u30e9\u30e0\u306b\u5165\u308b\u306e\u3092\u9632\u304e\u307e\u3059\u3002\u7279\u306b\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u6cd5\u3084\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6cd5\u3067\u306e\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u306e\u5206\u6790\u3067\u306f\u3001\u5145\u586b\u5264\u306e\u9078\u629e\u3068\u305d\u306e\u914d\u7f6e\u304c\u5206\u6790\u7d50\u679c\u306e\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-6\" id=\"mokuji41\" style=\"font-size:22px\">\u5145\u586b\u5264\u3068\u5145\u586b\u4f4d\u7f6e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30e9\u30b9\uff08\u77f3\u82f1\uff09\u30a6\u30fc\u30eb\u306f\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3067\u6700\u3082\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u5145\u586b\u5264\u3067\u3042\u308a\u3001\u305d\u306e\u6c17\u5316\u4fc3\u9032\u4f5c\u7528\u3084\u4e0d\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u30c8\u30e9\u30c3\u30d7\u80fd\u529b\u306b\u512a\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u4ed6\u306e\u5145\u586b\u7269\u3068\u6bd4\u8f03\u3057\u3066\u975e\u5e38\u306b\u8cbb\u7528\u5bfe\u52b9\u679c\u304c\u9ad8\u3044\u9078\u629e\u80a2\u3067\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u3001\u7279\u306b\u30b3\u30b9\u30c8\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u91cd\u8996\u3059\u308b\u5834\u9762\u3067\u91cd\u5b9d\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6642\u306b\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5e95\u90e8\u4ed8\u8fd1\u306b\u30a6\u30fc\u30eb\u3092\u914d\u7f6e\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u30a6\u30fc\u30eb\u304c\u306a\u3044\u3068\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u6bd4\u8f03\u7684\u9577\u3044\u6642\u9593\u30e9\u30a4\u30ca\u30fc\u5185\u306b\u6ede\u7559\u3057\u3001\u6eb6\u5a92\u306e\u84b8\u6c17\u304c\u81a8\u5f35\u3059\u308b\u6642\u9593\u3082\u5897\u3048\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u6eb6\u5a92\u3068\u5171\u306b\u6eb6\u8cea\uff08\u5206\u6790\u5bfe\u8c61\u6210\u5206\uff09\u304c\u30e9\u30a4\u30ca\u30fc\u306e\u4e0a\u90e8\u304b\u3089\u6392\u51fa\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30a6\u30fc\u30eb\u304c\u5e95\u90e8\u306b\u914d\u7f6e\u3055\u308c\u308b\u3053\u3068\u3067\u3001\u6700\u3082\u63ee\u767a\u6027\u306e\u9ad8\u3044\u6210\u5206\u4ee5\u5916\u306e\u6210\u5206\u304c\u30a6\u30fc\u30eb\u5185\u3067\u6c17\u5316\u3057\u3001\u6eb6\u5a92\u306e\u307f\u304c\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u81a8\u5f35\u3057\u307e\u3059\u3002\u3053\u306e\u914d\u7f6e\u306b\u3088\u308a\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u78ba\u5b9f\u306b\u6c17\u5316\u3055\u308c\u3001\u5b89\u5b9a\u3057\u305f\u5206\u6790\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u306b\u3088\u308b\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3067\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u592e\u90e8\u3084\u4e0a\u90e8\u4ed8\u8fd1\u306b\u30a6\u30fc\u30eb\u3092\u914d\u7f6e\u3059\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u53e3\u6ede\u7559\u6642\u9593\u304c\u975e\u5e38\u306b\u77ed\u3044\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u306e\u30d2\u30fc\u30c6\u30a3\u30f3\u30b0\u30be\u30fc\u30f3\u306b\u3068\u3069\u307e\u308b\u3053\u3068\u3067\u3001\u6c17\u5316\u3092\u4fc3\u9032\u3055\u305b\u3001\u5206\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u308b\u305f\u3081\u3067\u3059\u3002\u307e\u305f\u3001\u30a6\u30fc\u30eb\u306f\u30e9\u30a4\u30ca\u30fc\u306e\u71b1\u5bb9\u91cf\u3092\u5897\u52a0\u3001\u30b5\u30f3\u30d7\u30eb\u6c17\u5316\u4e2d\u306e\u6e29\u5ea6\u3092\u5b89\u5b9a\u3055\u305b\u3001\u518d\u73fe\u6027\u3092\u9ad8\u3081\u308b\u5f79\u5272\u3082\u679c\u305f\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001Restek\u306ePrecision\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30a6\u30fc\u30eb\u3092\u30e9\u30a4\u30ca\u30fc\u306e\u6bd4\u8f03\u7684\u9ad8\u3044\u4f4d\u7f6e\u306b\u914d\u7f6e\u3057\u3066\u304a\u308a\u3001\u30a6\u30fc\u30eb\u306e\u4e0a\u4e0b\u306b\u30ac\u30e9\u30b9\u306e\u304f\u307c\u307f\u3092\u3064\u3051\u3066\u30a6\u30fc\u30eb\u3092\u56fa\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\uff08<strong>Figure 6<\/strong>\uff09\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b7\u30ea\u30f3\u30b8\u30cb\u30fc\u30c9\u30eb\u304c\u30a6\u30fc\u30eb\u306b\u5165\u308b\u4f4d\u7f6e\u3067\u6ce8\u5165\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u30a6\u30fc\u30eb\u304c\u91dd\u5148\u3092\u62ed\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u8a2d\u8a08\u306f\u3001\u6ce8\u5165\u306e\u518d\u73fe\u6027\u3068\u6b63\u78ba\u3055\u3092\u5411\u4e0a\u3055\u305b\u308b\u3068\u3068\u3082\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u6642\u306e\u554f\u984c\u3092\u9632\u304e\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30cb\u30fc\u30c9\u30eb\u306b\u30d0\u30ea\u304c\u3042\u308b\u3068\u30a6\u30fc\u30eb\u306e\u4f4d\u7f6e\u304c\u305a\u308c\u3001\u52b9\u679c\u304c\u8584\u308c\u3066\u3057\u307e\u3046\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u306e\u3088\u3046\u306a\u6ce8\u5165\u6280\u8853\u3092\u4f7f\u7528\u3059\u308b\u969b\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u30cb\u30fc\u30c9\u30eb\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u884c\u3046\u3053\u3068\u304c\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u9069\u5207\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u3088\u308a\u3001\u30a6\u30fc\u30eb\u306e\u4f4d\u7f6e\u304c\u6b63\u3057\u304f\u4fdd\u305f\u308c\u3001\u5b89\u5b9a\u3057\u305f\u5206\u6790\u304c\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> Restek Topaz Precision liner with wool\uff08\u30a6\u30fc\u30eb\u5165\u308aPrecision\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23305)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23305.jpg\" alt=\"figure-article-GNAR1991C-23305.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-7\" id=\"mokuji42\" style=\"font-size:22px\">\u4ee3\u66ff\u30a6\u30fc\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a6\u30fc\u30eb\u3092\u4e0d\u6d3b\u6027\u5316\u3059\u308b\u6280\u8853\u304c\u9032\u5c55\u3059\u308c\u3070\u3001\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u3001\u3088\u308a\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u3068\u3044\u3046\u306e\u3082\u3001\u5fae\u91cf\u306e\u30a6\u30fc\u30eb\u6d3b\u6027\u304c\u554f\u984c\u3068\u306a\u308b\u5206\u6790\u304c\u5c11\u306a\u304b\u3089\u305a\u3042\u308b\u304b\u3089\u3067\u3059\u3002\u3053\u3046\u3057\u305f\u5834\u5408\u3001\u7279\u306b\u6ce8\u76ee\u3055\u308c\u308b\u306e\u304c\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08<strong>Figure 7<\/strong>\uff09\u306e\u3088\u3046\u306a\u7279\u6b8a\u306a\u30e9\u30a4\u30ca\u30fc\u3067\u3059\u3002\u3053\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u5145\u586b\u7269\u306e\u6d3b\u6027\u306b\u6700\u3082\u6ce8\u610f\u3092\u6255\u308f\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u304a\u3044\u3066\u3001\u975e\u5e38\u306b\u52b9\u679c\u7684\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059\u3002\u30a6\u30fc\u30eb\u306e\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3068\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u306e\u7d44\u307f\u5408\u308f\u305b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u91ce\u306b\u304a\u3051\u308b\u65b0\u305f\u306a\u7a81\u7834\u53e3\u3092\u958b\u304f\u3082\u306e\u3068\u3057\u3066\u3001\u4eca\u5f8c\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u307e\u3059\u307e\u3059\u6ce8\u76ee\u3055\u308c\u308b\u3079\u304d\u6280\u8853\u3067\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> Restek Topaz cyclo double taper liner\uff08\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23310)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23310.jpg\" alt=\"figure-article-GNAR1991C-23310.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">                                \u30ab\u30bf\u30ed\u30b0No. 23310                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Cyclo Double Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji5\">\u6ce8\u5165\u65b9\u6cd5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30a4\u30ca\u30fc\u306e\u3055\u307e\u3056\u307e\u306a\u30b9\u30bf\u30a4\u30eb\u3068\u3001\u305d\u308c\u305e\u308c\u306e\u30e9\u30a4\u30ca\u30fc\u304c\u5206\u6790\u7d50\u679c\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306b\u3064\u3044\u3066\u306f\u3054\u7406\u89e3\u3044\u305f\u3060\u3051\u305f\u3067\u3057\u3087\u3046\u304b\u3002\u6b21\u306b\u6ce8\u76ee\u3059\u3079\u304d\u306f\u6ce8\u5165\u65b9\u6cd5\u3067\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u3068\u6ce8\u5165\u65b9\u6cd5\u3092\u3069\u306e\u3088\u3046\u306b\u7d44\u307f\u5408\u308f\u305b\u308b\u304b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u5de6\u53f3\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20\u3067\u3059\u3002\u6700\u9069\u306a\u7d44\u307f\u5408\u308f\u305b\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3001\u7cbe\u5bc6\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u9375\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-8\" id=\"mokuji51\" style=\"font-size:22px\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e\u6fc3\u5ea6\u304c\u6bd4\u8f03\u7684\u9ad8\u3044\u5834\u5408\u3084\u3001\u691c\u51fa\u4e0b\u9650\u3092\u7279\u306b\u4f4e\u304f\u3059\u308b\u5fc5\u8981\u304c\u306a\u3044\u5834\u5408\u306b\u9069\u3057\u305f\u6ce8\u5165\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306e\u7279\u5fb4\u3068\u3057\u3066\u3001\u6ce8\u5165\u53e3\u3067\u306e\u6d41\u901f\u304c\u901f\u304f\u3001\u4e00\u90e8\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u30b5\u30f3\u30d7\u30eb\u304cGC\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u3001\u6b8b\u308a\u304c\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304b\u3089\u6392\u51fa\u3055\u308c\u308b\u70b9\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u6d41\u901f\u304c\u901f\u3044\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u5185\u306b\u3068\u3069\u307e\u308b\u6642\u9593\u306f\u77ed\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u52b9\u7387\u7684\u304b\u3064\u518d\u73fe\u6027\u826f\u304f\u6ce8\u5165\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u8fc5\u901f\u306b\u6c17\u5316\u3055\u305b\u3066\u6df7\u5408\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3068\u6df7\u5408\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30a6\u30fc\u30eb\u5165\u308aTopaz Precision\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\uff08<strong>Figure 8<\/strong>\uff09\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u3092\u5185\u8535\u3057\u3066\u304a\u308a\u3001\u30a6\u30fc\u30eb\u306e\u4e0a\u4e0b\u306b\u30ac\u30e9\u30b9\u306e\u304f\u307c\u307f\u3092\u3064\u3051\u3066\u30a6\u30fc\u30eb\u3092\u3057\u3063\u304b\u308a\u56fa\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u30a6\u30fc\u30eb\u306e\u914d\u7f6e\u304c\u4e00\u5b9a\u3067\u3042\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u518d\u73fe\u6027\u306e\u9ad8\u3044\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u30a6\u30fc\u30eb\u304c\u3042\u308b\u305f\u3081\u8868\u9762\u7a4d\u304c\u5897\u52a0\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3068\u6df7\u5408\u304c\u3055\u3089\u306b\u52b9\u7387\u3088\u304f\u9032\u307f\u307e\u3059\u3002\u305d\u306e\u4e0a\u3001\u6ce8\u5165\u6642\u306b\u30b7\u30ea\u30f3\u30b8\u30cb\u30fc\u30c9\u30eb\u304c\u30a6\u30fc\u30eb\u3067\u62ed\u308f\u308c\u308b\u305f\u3081\u3001\u518d\u73fe\u6027\u304c\u9ad8\u307e\u308a\u3001\u7d50\u679c\u306b\u5b89\u5b9a\u6027\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002Topaz Precision\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30ca\u30fc\u306f\u30a6\u30fc\u30eb\u3092\u5145\u586b\u3057\u305f\u72b6\u614b\u3067\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u308b\u306e\u3067\u3001\u30e9\u30a4\u30ca\u30fc\u3082\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306a\u7279\u6027\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7279\u6027\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u306b\u3088\u308b\u591a\u304f\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u512a\u308c\u305f\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> Restek Topaz Precision liner with wool\uff08\u30a6\u30fc\u30eb\u5165\u308aPrecision\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09(cat.# 23305)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23305.jpg\" alt=\"figure-article-GNAR1991C-23305.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-9\" id=\"mokuji52\" style=\"font-size:22px\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e\u6fc3\u5ea6\u304c\u4f4e\u3044\u5834\u5408\u306b\u7279\u306b\u6709\u52b9\u306a\u6ce8\u5165\u624b\u6cd5\u3067\u3059\u3002\u3053\u306e\u6ce8\u5165\u65b9\u6cd5\u3067\u306f\u3001\u6700\u521d\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u9589\u3058\u3001\u6ce8\u5165\u53e3\u3092\u901a\u904e\u3059\u308b\u3059\u3079\u3066\u306e\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u304c\u30d7\u30ed\u30b0\u30e9\u30e0\u3055\u308c\u305f\u6642\u9593\uff08\u300c\u30d1\u30fc\u30b8\u30d0\u30eb\u30d6\u30bf\u30a4\u30e0\u300d\u307e\u305f\u306f\u300c\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6642\u9593\u300d\u3068\u547c\u3070\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\uff09\u3001GC\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u958b\u304d\u3001\u6c17\u5316\u3055\u308c\u305f\u6eb6\u5a92\u3092\u30d1\u30fc\u30b8\uff08\u9664\u53bb\uff09\u3057\u307e\u3059\u3002\u9069\u5207\u306a\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u884c\u3048\u3070\u3001\u6fc3\u5ea6\u304c\u4f4e\u3044\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u3067\u3042\u3063\u3066\u3082\u305d\u306e\u7d0499%\u304cGC\u30ab\u30e9\u30e0\u306b\u52b9\u7387\u7684\u306b\u79fb\u9001\u3055\u308c\u3001\u7cbe\u5ea6\u306e\u9ad8\u3044\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f4e\u6fc3\u5ea6\u6210\u5206\u306e\u9ad8\u7cbe\u5ea6\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u307e\u305a\u30a6\u30fc\u30eb\u5165\u308aTopaz\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08<strong>Figure 9<\/strong>\uff09\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u5e95\u90e8\u306e\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u8a2d\u8a08\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3068\u91d1\u5c5e\u88fd\u6ce8\u5165\u53e3\u30b7\u30fc\u30eb\u3068\u306e\u63a5\u89e6\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u306b\u96c6\u4e2d\u3055\u305b\u308b\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u7cbe\u5ea6\u304c\u5411\u4e0a\u3057\u3001\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u304c\u9ad8\u307e\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30a6\u30fc\u30eb\u306f\u6ce8\u5165\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u6355\u6349\u3057\u3001\u6c17\u5316\u3059\u308b\u5834\u6240\u3092\u3082\u305f\u3089\u3059\u4e00\u65b9\u3067\u3001\u9ad8\u4fa1\u306aGC\u30ab\u30e9\u30e0\u3092\u6c5a\u67d3\u3059\u308b\u4e0d\u63ee\u767a\u6027\u306e\u300c\u6c5a\u308c\u300d\u3082\u30c8\u30e9\u30c3\u30d7\u3057\u307e\u3059\u3002Topaz\u30e9\u30a4\u30ca\u30fc\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u30a6\u30fc\u30eb\u306f\u5145\u586b\u3057\u305f\u5f8c\u306b\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u308b\u306e\u3067\u3001\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306a\u7279\u6027\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7279\u6027\u306b\u3088\u3063\u3066\u3001\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u5fae\u91cf\u3057\u304b\u5b58\u5728\u3057\u306a\u3044\u5834\u5408\u3067\u3082\u3001\u7cbe\u5ea6\u826f\u304f\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3067\u304d\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3051\u308b\u51fa\u767a\u70b9\u3068\u3057\u3066\u6700\u9069\u306a\u9078\u629e\u80a2\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> Restek Topaz single taper liner with wool\uff08\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23303)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"101\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1024x101.jpg\" alt=\"\" class=\"wp-image-20583\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1024x101.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-300x30.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-768x76.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303-1536x151.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23303.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-10\" id=\"mokuji53\" style=\"font-size:22px\">\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u306f\u3001\u7279\u306b\u5fae\u91cf\u30ec\u30d9\u30eb\u3067\u306e\u5206\u6790\u304c\u6c42\u3081\u3089\u308c\u308b\u5834\u5408\u306b\u4f7f\u7528\u3055\u308c\u308b\u6280\u8853\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e\u640d\u5931\u3092\u9632\u3050\u305f\u3081\u306b\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u5316\u5408\u7269\u304c\u9ad8\u6e29\u306a\u6ce8\u5165\u53e3\u306b\u304a\u3044\u3066\u30a6\u30fc\u30eb\u3084\u30e9\u30a4\u30ca\u30fc\u5e95\u90e8\u306e\u91d1\u5c5e\u88fd\u30b7\u30fc\u30eb\u3068\u306e\u63a5\u89e6\u306b\u3088\u3063\u3066\u5206\u89e3\u3001\u5438\u7740\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u5834\u5408\u3001\u3053\u306e\u624b\u6cd5\u304c\u9078\u3070\u308c\u307e\u3059\u3002\u30c0\u30a4\u30ec\u30af\u30c8\u6ce8\u5165\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u9ad8\u6e29\u306e\u6ce8\u5165\u53e3\u3067\u6c17\u5316\u3055\u308c\u3001\u305d\u306e\u5f8c\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u901a\u3058\u3066GC\u30ab\u30e9\u30e0\u3078\u76f4\u63a5\u5c0e\u5165\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u3067\u6ce8\u76ee\u3059\u3079\u304d\u306f\u3001Topaz Uniliner\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9769\u65b0\u7684\u306a\u8a2d\u8a08\u3067\u3059\u3002Topaz Uniliner\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u5e95\u90e8\u306b\u300c\u30d7\u30ec\u30b9\u30d5\u30a3\u30c3\u30c8\u300d\u30b3\u30cd\u30af\u30bf\u3092\u5185\u8535\u3057\u3066\u304a\u308a\u3001\u3053\u306e\u30b3\u30cd\u30af\u30bf\u304cGC\u30ab\u30e9\u30e0\u3068\u30e9\u30a4\u30ca\u30fc\u3092\u5bc6\u5c01\u3057\u307e\u3059\u3002\u3053\u306e\u8a2d\u8a08\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u5e95\u90e8\u306e\u91d1\u5c5e\u88fd\u30b7\u30fc\u30eb\u3068\u63a5\u89e6\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u7cbe\u5bc6\u306a\u5206\u6790\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001Topaz Uniliner\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u5fdc\u3058\u3066\u6700\u9069\u306a\u5f62\u614b\u3092\u9078\u629e\u3067\u304d\u308b2\u3064\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u304c\u3042\u308a\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u4e0a\u90e8\u306b\u5c0f\u3055\u306a\u30db\u30fc\u30eb\u304c\u958b\u3044\u3066\u3044\u308bUniliner\uff08<strong>Figure 10<\/strong>\uff09\u306f\u3001\u5206\u6790\u5bfe\u8c61\u7269\u304c\u6eb6\u5a92\u30d4\u30fc\u30af\u304b\u3089\u5341\u5206\u306b\u96e2\u308c\u3066\u6eb6\u51fa\u3059\u308b\u5834\u5408\u306b\u6700\u9069\u3067\u3059\u3002\u4e00\u65b9\u3001\u30e9\u30a4\u30ca\u30fc\u5e95\u90e8\uff08\u30ab\u30e9\u30e0\u30b7\u30fc\u30eb\u5074\uff09\u306b\u30db\u30fc\u30eb\u304c\u958b\u3044\u3066\u3044\u308bUniliner\uff08<strong>Figure 11<\/strong>\uff09\u306f\u3001\u5206\u6790\u5bfe\u8c61\u7269\u304c\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3067\u3042\u308b\u5834\u5408\u3084\u3001\u6eb6\u5a92\u30d4\u30fc\u30af\u306e\u30c6\u30fc\u30ea\u30f3\u30b0\u306e\u5f71\u97ff\u3092\u907f\u3051\u305f\u3044\u5834\u5408\u306b\u63a8\u5968\u3055\u308c\u307e\u3059\u3002Topaz Uniliner\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306e\u7cbe\u5ea6\u304c\u5927\u304d\u304f\u5411\u4e0a\u3057\u3001\u7d50\u679c\u7684\u306b\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 10:<\/strong> Restek Topaz Uniliner inlet liner with hole near top\uff08\u4e0a\u90e8\u4ed8\u8fd1\u306b\u30db\u30fc\u30eb\u304c\u3042\u308bUniliner\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23311)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23311.jpg\" alt=\"figure-article-GNAR1991C-23311.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23311\">                                \u30ab\u30bf\u30ed\u30b0No. 23311                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Drilled Uniliner (Hole near Top) Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23311\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 11:<\/strong> Restek Topaz Uniliner inlet liner with hole near bottom\uff08\u5e95\u90e8\u4ed8\u8fd1\u306b\u30db\u30fc\u30eb\u304c\u3042\u308bUniliner\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23306)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"101\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306-1024x101.jpg\" alt=\"\" class=\"wp-image-20595\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306-1024x101.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306-300x30.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306-768x76.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306-1536x151.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23306.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23306\">                                \u30ab\u30bf\u30ed\u30b0No. 23306                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Drilled Uniliner (Hole near Bottom) Inlet Liner, 4.0 mm x 6.3 x 78.5 for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23306\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-11\" id=\"mokuji54\" style=\"font-size:22px\">\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u6ce8\u5165\u306b\u3088\u308b\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u306f\u3001\u6db2\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u3068\u306f\u6839\u672c\u7684\u306b\u7570\u306a\u308a\u307e\u3059\u3002\u6db2\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u5834\u5408\u3001\u6ce8\u5165\u53e3\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u6c17\u5316\u3055\u305b\u3066\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u5834\u5408\u3001\u6ce8\u5165\u53e3\u306e\u5f79\u5272\u306f\u30b5\u30f3\u30d7\u30eb\u3092\u52b9\u7387\u3088\u304f\u30ab\u30e9\u30e0\u306b\u79fb\u9001\u3059\u308b\u3053\u3068\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u70b9\u3067\u3001\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u306b\u306f\u7279\u5225\u306a\u914d\u616e\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c17\u4f53\u30b5\u30f3\u30d7\u30eb\u306b\u6700\u9069\u306a\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u30ab\u30e9\u30e0\u306b\u52b9\u7387\u3088\u304f\u79fb\u9001\u3055\u308c\u308b\u3053\u3068\u3092\u91cd\u8996\u3057\u3001\u53ef\u80fd\u306a\u9650\u308a\u72ed\u3044\u30b5\u30f3\u30d7\u30eb\u30d0\u30f3\u30c9\u3092\u7dad\u6301\u3059\u308b\u8a2d\u8a08\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u5f84\uff08ID\uff09\u306f\u5c0f\u3055\u304f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u62e1\u6563\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u76ee\u7684\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001\u5185\u5f841.0 mm\u306eTopaz\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\uff08<strong>Figure 12<\/strong>\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 12:<\/strong> Restek Topaz straight liner (1 mm)\uff08\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc Agilent GC\u7528\uff09 (cat.# 23333)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR1991C-23333.jpg\" alt=\"figure-article-GNAR1991C-23333.jpg\" title=\"-\"><\/figure>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\"> <\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23333\">                                \u30ab\u30bf\u30ed\u30b0No. 23333                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Straight Inlet Liner, 1.0 mm x 6.3 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23333\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-12\" id=\"mokuji55\" style=\"font-size:22px\">\u6607\u6e29\u6c17\u5316 (PTV) \u6ce8\u5165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PTV\u6ce8\u5165\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u6ce8\u5165\u53e3\u306b\u6ce8\u5165\u3055\u308c\u308b\u969b\u3001\u6ce8\u5165\u53e3\u306e\u6e29\u5ea6\u306f\u4f4e\u6e29\u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6ce8\u5165\u53e3\u306f\u305d\u306e\u5f8c\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u6607\u6e29\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u6607\u6e29\u904e\u7a0b\u306b\u3088\u308a\u3001\u6eb6\u5a92\u304c\u307e\u305a\u6c17\u5316\u3055\u308c\u3066\u6392\u51fa\u3055\u308c\u3001\u305d\u306e\u5f8c\u3001\u5206\u6790\u5bfe\u8c61\u3068\u306a\u308b\u5316\u5408\u7269\u304c\u6b21\u7b2c\u306b\u6c17\u5316\u3057\u3001\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PTV\u7528\u6ce8\u5165\u53e3\u3092\u53d6\u308a\u6271\u3046\u30e1\u30fc\u30ab\u30fc\u306f\u3044\u304f\u3064\u304b\u3042\u308a\u3001\u5404\u30e1\u30fc\u30ab\u30fc\u306e\u6ce8\u5165\u53e3\u5f62\u72b6\u306b\u3088\u308a\u30e9\u30a4\u30ca\u30fc\u306f\u7570\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30e9\u30a4\u30ca\u30fc\u306b\u5171\u901a\u3059\u308b\u7279\u5fb4\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u5f84\u304c\u5c0f\u3055\u304f\u3001\u5185\u8868\u9762\u306b\u30d0\u30c3\u30d5\u30eb\u307e\u305f\u306f\u30c7\u30a3\u30f3\u30d7\u30eb\u304c\u8a2d\u3051\u3089\u308c\u3066\u3044\u308b\u70b9\u3067\u3059\u3002\u3053\u306e\u30d0\u30c3\u30d5\u30eb\u3084\u30c7\u30a3\u30f3\u30d7\u30eb\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5185\u8868\u9762\u7a4d\u3092\u5897\u52a0\u3055\u305b\u307e\u3059\u304c\u3053\u308c\u306f\u30b5\u30f3\u30d7\u30eb\u3092\u7559\u307e\u308a\u3084\u3059\u304f\u3059\u308b\u3060\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u6ce8\u5165\u53e3\u306e\u6e29\u5ea6\u304c\u4e0a\u6607\u3059\u308b\u306b\u3064\u308c\u3066\u3001\u6ce8\u5165\u53e3\u304b\u3089\u30b5\u30f3\u30d7\u30eb\u3078\u306e\u71b1\u304c\u4f1d\u308f\u308a\u3084\u3059\u304f\u3082\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u30b5\u30f3\u30d7\u30eb\u306f\u52b9\u7387\u7684\u306b\u6c17\u5316\u3057\u307e\u3059\u3002PTV\u7528\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u969b\u306b\u306f\u3001\u3069\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u6ce8\u5165\u53e3\u304c\u5fc5\u8981\u306a\u306e\u304b\u78ba\u8a8d\u3057\u3001\u5c11\u306a\u304f\u3068\u30821\u3064\u306e\u30d0\u30c3\u30d5\u30eb\u307e\u305f\u306f\u30c7\u30a3\u30f3\u30d7\u30eb\u3092\u5099\u3048\u305f\u5185\u5f84\u306e\u5c0f\u3055\u3044Topaz\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#table_of_contents\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji6\">\u30e9\u30a4\u30ca\u30fc\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306b\u304a\u3051\u308b\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306e\u969b\u306b\u91cd\u8981\u306a\u5f79\u5272\u3092\u62c5\u3063\u3066\u304a\u308a\u3001\u305d\u306e\u72b6\u614b\u304c\u5206\u6790\u7d50\u679c\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306f\u5c0f\u3055\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u7279\u306b\u30b5\u30f3\u30d7\u30eb\u304c\u30b7\u30b9\u30c6\u30e0\u306b\u4e0e\u3048\u308b\u8ca0\u62c5\u304c\u5927\u304d\u3044\u5834\u5408\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u5b9a\u671f\u7684\u306a\u4ea4\u63db\u306f\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u554f\u984c\u306b\u60a9\u3080\u524d\u306b\u30e9\u30a4\u30ca\u30fc\u4ea4\u63db\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30b5\u30f3\u30d7\u30eb\u5206\u89e3\u306b\u3088\u308b\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u60aa\u5316<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u5438\u7740\u306b\u3088\u308b\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3068\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u4f4e\u4e0b<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u306e\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308a\u3001\u7279\u5b9a\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\uff08\u4f8b\u3048\u3070\u9ad8\u5206\u5b50\u5316\u5408\u7269\uff09\u304c\u640d\u5931\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b<\/li>\n\n\n\n<li>\u30d4\u30fc\u30af\u9762\u7a4d\u306e\u518d\u73fe\u6027\u304c\u60aa\u3044<\/li>\n\n\n\n<li>\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3084\u30bb\u30d7\u30bf\u30e0\u7c92\u5b50\u306b\u3088\u308b\u4e0d\u8981\u306a\u30d4\u30fc\u30af\u306e\u767a\u751f\u3084\u3001\u30b5\u30f3\u30d7\u30eb\u3068\u306e\u671b\u307e\u3057\u304f\u306a\u3044\u76f8\u4e92\u4f5c\u7528\u304c\u7591\u308f\u308c\u308b<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30a4\u30ca\u30fc\u3092\u5747\u4e00\u306a\u6e29\u5ea6\u72b6\u614b\u3067\u52b9\u7387\u3088\u304f\u4f7f\u7528\u3059\u308b\u305f\u3081\u306b\u3001\u4ed6\u306e\u6d88\u8017\u54c1\u3068\u540c\u69d8\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u3082\u77ed\u3044\u30b9\u30d1\u30f3\u3067\u6bce\u56de\u4f7f\u7528\u524d\u306b\u71b1\u5e73\u8861\u5316\u3092\u884c\u3046\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u6c5a\u67d3\u7269\u8cea\u3084\u4e0d\u7d14\u7269\u3092\u9664\u53bb\u3059\u308b\u306e\u306b\u3001\u5206\u6790\u65b9\u6cd5\u3067\u6570\u56de\u306e\u30d6\u30e9\u30f3\u30af\u6ce8\u5165\u3092\u884c\u3046\u3001\u307e\u305f\u306f\u30b7\u30b9\u30c6\u30e0\u304c\u8a31\u5bb9\u3059\u308b\u5834\u5408\u3001\u6ce8\u5165\u53e3\u6e29\u5ea6\u3092\u6a19\u6e96\u8a2d\u5b9a\u6e29\u5ea6\u3088\u308a\u5c11\u3057\u9ad8\u3081\u306b\u8a2d\u5b9a\u3059\u308b\uff08\u4f8b\uff1a+10 \u00b0C\uff09\u3053\u3068\u304c\u52b9\u679c\u7684\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"border-radius:15px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\" id=\"mokuji7\">Restek Topaz GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek Topaz GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u753b\u671f\u7684\u306a\u6280\u8853\u3068\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u3063\u3066\u3001True Blue Performance\u306f\u6b21\u306e\u30ec\u30d9\u30eb\u3078:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u4e0d\u6d3b\u6027\u5ea6<\/strong>\u2014\u5fae\u91cf\u5206\u6790\u3092\u6b63\u78ba\u304b\u3064\u7cbe\u5ea6\u826f\u304f\u304a\u3053\u306a\u3046\u305f\u3081\u306b\u3001\u305d\u306e\u5206\u89e3\u6027\u306f\u6975\u3081\u3066\u4f4e\u304f\u6291\u3048\u3089\u308c\u3066\u3044\u307e\u3059<\/li>\n\n\n\n<li><strong>\u518d\u73fe\u6027<\/strong>\u2014\u69d8\u3005\u306a\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u512a\u308c\u305f\u4fe1\u983c\u6027\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u3001\u6975\u3081\u3066\u53b3\u3057\u3044\u88fd\u9020\u7ba1\u7406\u3068QC\u30c6\u30b9\u30c8\u3092\u304a\u3053\u306a\u3063\u3066\u3044\u307e\u3059<\/li>\n\n\n\n<li><strong>\u751f\u7523\u6027<\/strong>\u2014\u4e26\u5916\u308c\u305f\u6e05\u6d44\u5ea6\u306b\u3088\u308a\u3001GC\u7a3c\u50cd\u6642\u9593\u3068\u30e9\u30dc\u306e\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306f\u6700\u5927\u9650\u306b\u767a\u63ee\u3067\u304d\u307e\u3059<\/li>\n<\/ul>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns45322_3c84e3-a6{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns45322_3c84e3-a6 .kt-button{font-weight:normal;font-style:normal;}.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns45322_3c84e3-a6 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns45322_3c84e3-a6\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn45322_96d128-a9.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn45322_96d128-a9.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn45322_96d128-a9.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn45322_96d128-a9.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn45322_96d128-a9 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNBR2638-JA\/japanese-topaz-gc-inlet-liners\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">\u8a73\u7d30\u306f\u3053\u3061\u3089\u304b\u3089<\/span><\/a><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"799\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz-1024x799.png\" alt=\"\" class=\"wp-image-29817\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz-1024x799.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz-300x234.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz-768x599.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz-1536x1198.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Topaz.png 1632w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u6700\u9069\u306aGC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u3069\u306e\u3088\u3046\u306b\u9078\u629e\u3057\u307e\u3059\u304b\uff1f \u305f\u304f\u3055\u3093\u306e\u9078\u629e\u80a2\u304c\u3042\u308b\u305f\u3081\u3001\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306f\u96e3\u3057\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002 \u3053\u306e\u8cc7\u6599\u3067\u306f\u3001Restek\u304c\u5404\u6ce8\u5165\u65b9\u6cd5\u306b\u6700\u9069\u306aGC\u30e9\u30a4\u30ca\u30fc\u9078\u629e\u304c\u7c21\u5358\u306b\u3067\u304d\u308b\u3088\u3046\u306b\u304a\u624b\u4f1d\u3044\u3057\u307e\u3059\u3002 \u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u3092\u30b7\u30f3\u30d7\u30eb\u306b\u3059\u308b\u65b9\u6cd5\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":7099,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[2802],"product-library":[2566,2566,2552],"resource-technique":[2340],"ppma_author":[2814,414],"class_list":["post-45322","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-topaz-liners","resource-type-selection-guides","product-library-inlet-supplies-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}],"resource-type":[{"value":2802,"label":"Selection Guides"}],"product-library":[{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR1991-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45322","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45322"}],"version-history":[{"count":20,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45322\/revisions"}],"predecessor-version":[{"id":97214,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45322\/revisions\/97214"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7099"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45322"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45322"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45322"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45322"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45322"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45322"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45322"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45322"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45322"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}