{"id":45323,"date":"2025-10-08T17:55:31","date_gmt":"2025-10-08T17:55:31","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysis-of-volatile-organic-compounds-and-odorants-in-drinking-water-via-hs-spme-arrow-gc-ms-japan\/"},"modified":"2026-07-31T21:04:12","modified_gmt":"2026-07-31T21:04:12","slug":"analysis-of-volatile-organic-compounds-and-odorants-in-drinking-water-via-hs-spme-arrow-gc-ms-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan4283-ja\/analysis-of-volatile-organic-compounds-and-odorants-in-drinking-water-via-hs-spme-arrow-gc-ms-japan","title":{"rendered":"HS-SPME Arrow-GC-MS\u306b\u3088\u308b\u98f2\u6599\u6c34\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u3068\u81ed\u6c17\u5316\u5408\u7269\u306e\u9ad8\u7cbe\u5ea6\u5206\u6790"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u98f2\u6599\u6c34\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VOCs\uff09\u306e\u691c\u67fb\u306f\u3001\u305d\u306e\u5b89\u5168\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u5e83\u304f\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30e1\u30c1\u30eb\u30a4\u30bd\u30dc\u30eb\u30cd\u30aa\u30fc\u30eb\uff08MIB\uff09\u3084\u30b8\u30a7\u30aa\u30b9\u30df\u30f3\u3068\u3044\u3063\u305f\u81ed\u6c17\u7269\u8cea\u306f\u3001\u4e0d\u5feb\u306a\u306b\u304a\u3044\u306e\u539f\u56e0\u3068\u3057\u3066\u6ce8\u76ee\u3055\u308c\u3066\u304a\u308a\u3001\u5206\u6790\u5bfe\u8c61\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u901a\u5e38\u306f\u5225\u3005\u306b\u884c\u308f\u308c\u308bVOCs\u3068\u81ed\u6c17\u7269\u8cea\u306e\u5206\u6790\u624b\u6cd5\u3092\u7d71\u5408\u3057\u3001\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5b9f\u73fe\u3059\u308b\u65b9\u6cd5\u306e\u958b\u767a\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa\uff08SPME\uff09Arrow\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3068\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u30921\u3064\u306e\u88c5\u7f6e\u3067\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308a\u3001\u7279\u306b\u6709\u7528\u306a\u624b\u6cd5\u3067\u3059\u3002\u307e\u305f\u3001SPME Arrow\u306f\u30ec\u30fc\u30eb\u578b\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3092\u7528\u3044\u3066\u81ea\u52d5\u5316\u304c\u53ef\u80fd\u3067\u3042\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u8981\u3059\u308b\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u7c21\u7d20\u5316\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9-\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa-\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc-\u8cea\u91cf\u5206\u6790\uff08HS-SPME-GC-MS\uff09\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u98f2\u6599\u6c34\u4e2d\u306eVOCs\u304a\u3088\u3073\u81ed\u6c17\u7269\u8cea\u3092\u52b9\u7387\u7684\u306b\u6e2c\u5b9a\u3059\u308b\u624b\u6cd5\u3092\u63d0\u6848\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u624b\u6cd5\u306f\u30010.923\uff5e0.999\uff08\u5e73\u5747\uff1a0.998\uff09\u306e\u6c7a\u5b9a\u4fc2\u6570\uff08r\u00b2\u5024\uff09\u3092\u9054\u6210\u3059\u308b\u691c\u91cf\u7dda\u7bc4\u56f2\u3092\u793a\u3057\u30012\uff5e27%\uff08\u5e73\u5747\uff1a6%\uff09\u306e\u76f8\u5bfe\u6a19\u6e96\u8aa4\u5dee\uff08%RSE\uff09\u3001\u304a\u3088\u30732\uff5e15%\uff08\u5e73\u5747\uff1a4%\uff09\u306e\u518d\u73fe\u6027\uff08RSD\u5024\uff09\u3092\u9054\u6210\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5b9a\u91cf\u9650\u754c\uff08LOQ\uff09\u306f0.0029\uff5e3.033 ng\/mL\uff08\u5e73\u5747\uff1a0.223 ng\/mL\uff09\u3068\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VOCs\uff09\u306f\u3001\u305d\u306e\u6bd2\u6027\u3084\u4eba\u4f53\u3078\u306e\u5f71\u97ff\u304c\u77e5\u3089\u308c\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u691c\u67fb\u304c\u4e00\u822c\u7684\u306b\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u30012-\u30e1\u30c1\u30eb\u30a4\u30bd\u30dc\u30eb\u30cd\u30aa\u30fc\u30eb\uff08MIB\uff09\u3084\u30b8\u30a7\u30aa\u30b9\u30df\u30f3\u3068\u3044\u3063\u305f\u81ed\u6c17\u5316\u5408\u7269\u306f\u5065\u5eb7\u3078\u306e\u30ea\u30b9\u30af\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u571f\u81ed\u3055\u3084\u30ab\u30d3\u81ed\u3055\u3092\u4f34\u3046\u4e0d\u5feb\u306a\u5473\u3084\u81ed\u3044\u306e\u539f\u56e0\u3068\u306a\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u3082\u691c\u67fb\u5bfe\u8c61\u3068\u3057\u3066\u91cd\u8981\u8996\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002\u901a\u5e38\u3001VOC\u3068\u81ed\u6c17\u5316\u5408\u7269\u306e\u5206\u6790\u306f2\u3064\u306e\u5225\u3005\u306e\u65b9\u6cd5\u3067\u884c\u308f\u308c\u307e\u3059\u304c\u3001\u3053\u308c\u3089\u3092\u7d71\u5408\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u306e\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u5411\u4e0a\u3084\u30e9\u30dc\u306e\u52b9\u7387\u5316\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9-\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa-\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc-\u8cea\u91cf\u5206\u6790\uff08HS-SPME-GC-MS\uff09\u3092\u7528\u3044\u3066\u3001\u6c34\u4e2d\u306eVOC\u304a\u3088\u3073\u81ed\u6c17\u5316\u5408\u7269\u3092\u52b9\u7387\u7684\u306b\u5b9a\u91cf\u3059\u308b\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u63d0\u6848\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">VOC\u304a\u3088\u3073\u81ed\u6c17\u5316\u5408\u7269\u6eb6\u6db2\u306e\u8abf\u88fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u306b\u306f\u3001Restek\u793e\u88fd\u306e\u98f2\u6599\u6c34\u81ed\u6c17\u6a19\u6e96\u6eb6\u6db2 (cat# 30608) \u304a\u3088\u3073\u30ab\u30b9\u30bf\u30e0VOC\u6a19\u6e96\u6eb6\u6db2 \uff08<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnss3848-ja\/japan-simplify-workflows-and-increase-certainty-with-restek-custom-reference-standards\" target=\"_blank\" rel=\"noreferrer noopener\">\u300cRestek\u306e\u30ab\u30b9\u30bf\u30e0\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u3088\u308b\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u30b7\u30f3\u30d7\u30eb\u5316\u3068\u78ba\u5b9f\u6027\u306e\u5411\u4e0a\u300d<\/a>\u53c2\u7167\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08ISTD\uff09\u3068\u3057\u3066\u30d5\u30eb\u30aa\u30ed\u30d9\u30f3\u30bc\u30f3(cat# 30030)\u30011,4-\u30b8\u30aa\u30ad\u30b5\u30f3-d8 (cat# 30614)\u3001\u304a\u3088\u3073 4-\u30d6\u30ed\u30e2\u30d5\u30eb\u30aa\u30ed\u30d9\u30f3\u30bc\u30f3(cat# 30026)\u306e3\u7a2e\u985e\u3092\u9078\u629e\u3057\u307e\u3057\u305f\u3002VOC\u304a\u3088\u3073\u81ed\u6c17\u5316\u5408\u7269\u306e\u6821\u6b63\u70b9\u3054\u3068\u306b\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u7528\u3044\u3066\u500b\u5225\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u3001\u30e1\u30bd\u30c3\u30c9\u691c\u51fa\u9650\u754c\uff08MDL\uff09\u3092\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002\u672c\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u300120 mL\u306e\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\uff08HS\uff09\u30d0\u30a4\u30a2\u30eb\u3092\u4f7f\u7528\u3057\u3001\u6700\u7d42\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u91cf\u30925 mL\u3068\u3057\u307e\u3057\u305f\u3002\u6821\u6b63\u6fc3\u5ea6\u304a\u3088\u3073MDL\u78ba\u8a8d\u7528\u6fc3\u5ea6\u3092\u6c7a\u5b9a\u3057\u305f\u5f8c\u3001\u76ee\u7684\u306e\u6700\u7d42\u6fc3\u5ea6\u306b\u9054\u3059\u308b\u3088\u3046\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db210 \u00b5L\u3092\u6dfb\u52a0\u3059\u308b\u305f\u3081\u306e\u6fc3\u5ea6\u3092\u8a08\u7b97\u3057\u307e\u3057\u305f\u3002<br>\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u306e\u6fc3\u5ea6\u304a\u3088\u3073\u305d\u308c\u306b\u5bfe\u5fdc\u3059\u308b\u6821\u6b63\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u306f\u3001<strong>Table I<\/strong>\u304a\u3088\u3073<strong>Table II<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> VOC\u306e\u6821\u6b63\u6fc3\u5ea6\u3068\u4f5c\u696d\u6eb6\u6db2\u6fc3\u5ea6<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" colspan=\"3\"><strong>VOCs\u3000<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u6fc3\u5ea6\u306e\u30ec\u30d9\u30eb<\/strong><\/td><td><strong>\u6821\u6b63\u6fc3\u5ea6\u3000(ppb, ng\/mL)<\/strong><\/td><td><strong>\u4f5c\u696d\u6eb6\u6db2\u6fc3\u5ea6&nbsp; (ppb, ng\/mL)<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1<\/td><td>0.2<\/td><td>100<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2<\/td><td>0.5<\/td><td>250<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td>1<\/td><td>500<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><td>2<\/td><td>1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td>5<\/td><td>2500<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6<\/td><td>10<\/td><td>5000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7<\/td><td>25<\/td><td>12,500<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">8<\/td><td>75<\/td><td>37,500<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">9<\/td><td>200<\/td><td>100,000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u81ed\u6c17\u5316\u5408\u7269\u306e\u6821\u6b63\u6fc3\u5ea6\u3068\u4f5c\u696d\u6eb6\u6db2\u6fc3\u5ea6<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td colspan=\"3\"><strong>\u81ed\u6c17\u5316\u5408\u7269<\/strong><\/td><\/tr><tr><td><strong>\u6fc3\u5ea6\u306e\u30ec\u30d9\u30eb<\/strong><\/td><td><strong>\u6821\u6b63\u6fc3\u5ea6&nbsp; &nbsp;(ppb, ng\/mL)<\/strong><\/td><td><strong>\u4f5c\u696d\u6eb6\u6db2\u6fc3\u5ea6&nbsp; (ppb, ng\/mL)\u3000<\/strong><\/td><\/tr><tr><td>1<\/td><td>0.001<\/td><td>0.5<\/td><\/tr><tr><td>2<\/td><td>0.002<\/td><td>1<\/td><\/tr><tr><td>3<\/td><td>0.004<\/td><td>2<\/td><\/tr><tr><td>4<\/td><td>0.008<\/td><td>4<\/td><\/tr><tr><td>5<\/td><td>0.016<\/td><td>8<\/td><\/tr><tr><td>6<\/td><td>0.032<\/td><td>16<\/td><\/tr><tr><td>7<\/td><td>0.064<\/td><td>32<\/td><\/tr><tr><td>8<\/td><td>0.128<\/td><td>64<\/td><\/tr><tr><td>9<\/td><td>0.256<\/td><td>128<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u9078\u629e\u3057\u305f3\u7a2e\u985e\u306e\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08ISTD\uff09\u306f\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u7528\u3044\u3066\u6fc3\u5ea610 \u00b5g\/mL\uff08ppm\uff09\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3068\u3057\u3066\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u6821\u6b63\u7528\u304a\u3088\u3073MDL\u78ba\u8a8d\u7528\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u8abf\u88fd\u5f8c\u3001\u6700\u7d42\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u304c100 ng\/mL\uff08ppb\uff09\u3068\u306a\u308b\u3088\u3046\u306b\u3001\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db250 \u00b5L\u3092\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u6dfb\u52a0\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5404\u5316\u5408\u7269\u306e\u691c\u51fa\u9650\u754c\uff08MDL\uff09\u306f\u3001\u7c73\u56fd\u74b0\u5883\u4fdd\u8b77\u5e81\uff08EPA\uff09[2]\u306e\u898f\u5b9a\u306b\u57fa\u3065\u304f\u624b\u9806\u306b\u5f93\u3044\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u624b\u9806\u3067\u306f\u3001\u4f4e\u6fc3\u5ea6\u6dfb\u52a0\u30b5\u30f3\u30d7\u30eb\uff08VOC\u306f0.002\u304a\u3088\u30732 ng\/mL\u3001\u81ed\u6c17\u5316\u5408\u7269\u306f0.008 ng\/mL\uff09\u3092\u7528\u3044\u3001\u305d\u308c\u305e\u308c7\u56de\uff08n=7\uff09\u306e\u7e70\u308a\u8fd4\u3057\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002MDL\u78ba\u8a8d\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u6dfb\u52a0\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u306f\u3001<strong>Table III<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5f97\u3089\u308c\u305f\u6e2c\u5b9a\u5024\u306e\u6a19\u6e96\u504f\u5dee\u306b\u3001Student\u306et\u5024\uff083.143\uff09\u3092\u4e57\u3058\u3066MDL\u3092\u7b97\u51fa\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5404\u5316\u5408\u7269\u306e\u5b9a\u91cf\u9650\u754c\uff08LOQ\uff09\u306f\u3001MDL\u78ba\u8a8d\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u6a19\u6e96\u504f\u5dee\u309210\u500d\uff0810\u00d7\uff09\u3059\u308b\u3053\u3068\u3067\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> MDL\u78ba\u8a8d\u7528\u30b5\u30f3\u30d7\u30eb\u306e\u6dfb\u52a0\u6fc3\u5ea6\u306e\u30ec\u30d9\u30eb<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><tbody><tr><td>#<\/td><td><strong>\u5316\u5408\u7269<\/strong><\/td><td><strong>MDL\u78ba\u8a8d\u7528\u6fc3\u5ea6&nbsp; (ng\/mL, ppb)\u3000<\/strong><\/td><\/tr><tr><td>1<\/td><td>Chloroethene<\/td><td>0.2<\/td><\/tr><tr><td>2<\/td><td>1,1-Dichloroethene<\/td><td>0.2<\/td><\/tr><tr><td>3<\/td><td>Dichloromethane<\/td><td>2<\/td><\/tr><tr><td>4<\/td><td>trans-1,2-Dichloroethene<\/td><td>0.2<\/td><\/tr><tr><td>5<\/td><td>MTBE<\/td><td>0.02<\/td><\/tr><tr><td>6<\/td><td>cis-1,2-Dichloroethene<\/td><td>0.02<\/td><\/tr><tr><td>7<\/td><td>Chloroform<\/td><td>0.02<\/td><\/tr><tr><td>8<\/td><td>Carbon Tetrachloride<\/td><td>0.02<\/td><\/tr><tr><td>9<\/td><td>1,1,1-Trichloroethane<\/td><td>0.02<\/td><\/tr><tr><td>10<\/td><td>Benzene<\/td><td>0.02<\/td><\/tr><tr><td>11<\/td><td>1,2-Dichloroethane<\/td><td>0.02<\/td><\/tr><tr><td>12<\/td><td>Trichloroethene<\/td><td>0.02<\/td><\/tr><tr><td>13<\/td><td>1,2-Dichloropropane<\/td><td>0.02<\/td><\/tr><tr><td>14<\/td><td>Bromodichloromethane<\/td><td>2<\/td><\/tr><tr><td>15<\/td><td>1,4-Dioxane<\/td><td>0.02<\/td><\/tr><tr><td>16<\/td><td>cis-1,3-Dichloropropene<\/td><td>0.02<\/td><\/tr><tr><td>17<\/td><td>Toluene<\/td><td>0.02<\/td><\/tr><tr><td>18<\/td><td>Tetrachloroethene<\/td><td>0.02<\/td><\/tr><tr><td>19<\/td><td>trans-1,3-Dichloropropene<\/td><td>0.02<\/td><\/tr><tr><td>20<\/td><td>Dibromochloromethane<\/td><td>0.02<\/td><\/tr><tr><td>21<\/td><td>m,p-Xylene<\/td><td>0.02<\/td><\/tr><tr><td>22<\/td><td>o-Xylene<\/td><td>0.02<\/td><\/tr><tr><td>23<\/td><td>Bromoform<\/td><td>0.02<\/td><\/tr><tr><td>24<\/td><td>1,2-Dichlorobenzene<\/td><td>0.02<\/td><\/tr><tr><td>25<\/td><td>2-Methylisoborneol<\/td><td>0.008<\/td><\/tr><tr><td>26<\/td><td>Geosmin<\/td><td>0.008<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">HS-SPME Arrow-GC-MS \u30d1\u30e9\u30e1\u30fc\u30bf<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3059\u3079\u3066\u306e\u7d50\u679c\u306f\u3001HS-SPME Arrow-GC-MS \u3092\u4f7f\u7528\u3057\u3066\u5f97\u3089\u305f\u3082\u306e\u3067\u3059\u3002HS-SPME Arrow\u3001GC\u3001\u304a\u3088\u3073 MS \u30d1\u30e9\u30e1\u30fc\u30bf\u306f\u3001\u305d\u308c\u305e\u308c&nbsp;<strong>Table IV\u3001V\u3001<\/strong>\u304a\u3088\u3073<strong>VI<\/strong>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV:<\/strong> HS-SPME Arrow \u30d1\u30e9\u30e1\u30fc\u30bf<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td colspan=\"2\"><strong>CTC PAL \u30d1\u30e9\u30e1\u30fc\u30bf<\/strong><\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30e2\u30fc\u30c9<\/td><td>\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9<\/td><\/tr><tr><td>SPME\u88c5\u7f6e<\/td><td>1.10 mm SPME Arrow (cat.# 28903-1)<\/td><\/tr><tr><td>SPME\u76f8<\/td><td>120 \u00b5m CWR\/PDMS<\/td><\/tr><tr><td>\u30d0\u30a4\u30a2\u30eb\u8cab\u901a\u6df1\u3055<\/td><td>45 mm<\/td><\/tr><tr><td>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u8cab\u901a\u6df1\u3055<\/td><td>50 mm<\/td><\/tr><tr><td>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6e29\u5ea6\/\u6642\u9593 \u3000<\/td><td>30 \u00b0C\/120 s<\/td><\/tr><tr><td>\u62bd\u51fa\u6e29\u5ea6\/\u6642\u9593<\/td><td>30 \u00b0C\/120 s<\/td><\/tr><tr><td>\u8131\u7740\u6e29\u5ea6\/\u6642\u9593<\/td><td>280 \u00b0C\/1 min<\/td><\/tr><tr><td>\u5e73\u8861\u5316\u6e29\u5ea6\/\u6642\u9593<\/td><td>280 \u00b0C<\/td><\/tr><tr><td>\u30d7\u30ec\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0<\/td><td>1 min<\/td><\/tr><tr><td>\u30dd\u30b9\u30c8\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0<\/td><td>0 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong> GC \u30d1\u30e9\u30e1\u30fc\u30bf<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-theme-palette-3-color has-text-color has-link-color has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td colspan=\"2\"><strong><span>Agilent 7890B\/5977B GC-MS \u30d1\u30e9\u30e1\u30fc\u30bf<\/span><\/strong><\/td><\/tr><tr><td>\u30ab\u30e9\u30e0<\/td><td>Rtx-VMS\u2013 30 m x 0.25 mm x 1.40 \u00b5m (cat# 19915)<\/td><\/tr><tr><td>\u6ce8\u5165\u30e2\u30fc\u30c9<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8 (15:1)<\/td><\/tr><tr><td>\u6ce8\u5165\u91cf<\/td><td>CTC PAL\u30d1\u30e9\u30e1\u30fc\u30bf\u53c2\u7167<\/td><\/tr><tr><td>\u30e9\u30a4\u30ca\u30fc<\/td><td>Topaz 1.8 mm ID Straight\/SPME Inlet Liner (cat# 23280)<\/td><\/tr><tr><td>\u6ce8\u5165\u6e29\u5ea6<\/td><td>280 \u00b0C<\/td><\/tr><tr><td><span style=\"color: rgb(0, 0, 0);\">\u30d1\u30fc\u30b8\u30d5\u30ed\u30fc<\/span><\/td><td>3 mL\/min<\/td><\/tr><tr><td>\u30aa\u30fc\u30d6\u30f3<\/td><td>35 \u00b0C (hold 3 min) to 60 \u00b0C at 8 \u00b0C\/min (hold 0 min) to 280 \u00b0C (hold 3 min) at 30 \u00b0C\/min; Total time = 16.46 min<\/td><\/tr><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/td><td>He, constant flow<\/td><\/tr><tr><td>\u6d41\u901f<\/td><td>2.0 mL\/min<\/td><\/tr><tr><td>\u691c\u51fa\u5668<\/td><td>HES &#8211; MS<\/td><\/tr><tr><td>\u30e2\u30fc\u30c9<\/td><td>SIM<\/td><\/tr><tr><td>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u6e29\u5ea6<\/td><td>260 \u00b0C<\/td><\/tr><tr><td>\u30bd\u30fc\u30b9\u6e29\u5ea6<\/td><td>325 \u00b0C<\/td><\/tr><tr><td>\u30af\u30ef\u30c3\u30c9\u6e29\u5ea6<\/td><td>200 \u00b0C<\/td><\/tr><tr><td>\u53d6\u5f97\u7bc4\u56f2<\/td><td>29 &#8211; 300 amu<\/td><\/tr><tr><td>\u30ec\u30fc\u30c8<\/td><td>5.1 scans\/sec<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VI:<\/strong> MS SIM\u30d1\u30e9\u30e1\u30fc\u30bf<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td colspan=\"2\"><strong><span>5977B MS SIM \u30d1\u30e9\u30e1\u30fc\u30bf<\/span><\/strong><\/td><td><strong><span style=\"color: rgb(255, 255, 255);\">&nbsp;<\/span><\/strong><\/td><\/tr><tr><td><strong>\u30b0\u30eb\u30fc\u30d7\u756a\u53f7<\/strong><\/td><td><strong>\u958b\u59cb\u6642\u9593<\/strong><\/td><td><strong>\u8cea\u91cf\u3001Dwell Time<\/strong><\/td><\/tr><tr><td>Group 1<\/td><td>0 min<\/td><td>(62, 30) (64, 15)<\/td><\/tr><tr><td>Group 2<\/td><td>1.8 min<\/td><td>(61, 15) (96, 30)<\/td><\/tr><tr><td>Group 3<\/td><td>2.3 min<\/td><td>(49,30) (57, 30) (61, 30) (73, 30) (84, 30) (96, 30)<\/td><\/tr><tr><td>Group 4<\/td><td>3.5 min<\/td><td>(61, 30) (96, 30)<\/td><\/tr><tr><td>Group 5<\/td><td>4.3 min &nbsp; &nbsp;<\/td><td>(47, 30) (61, 30) (82,30) (83, 30) (97, 30) (117,30)<\/td><\/tr><tr><td>Group 6<\/td><td>4.9 min<\/td><td>(52 ,30) (78, 30)<\/td><\/tr><tr><td>Group 7<\/td><td>5.3 min<\/td><td>(49, 30) (62, 30) (70, 30)<\/td><\/tr><tr><td>Group 8<\/td><td>6.2 min<\/td><td>(63, 30) (76, 30) (83, 30) (129, 30)<\/td><\/tr><tr><td>Group 9<\/td><td>6.75 min<\/td><td>(57, 15) (64, 15) (88, 15) (96, 15)<\/td><\/tr><tr><td>Group 10<\/td><td>7.1 min<\/td><td>(65, 30) (75, 30) (91, 30) (110, 30)<\/td><\/tr><tr><td>Group 11<\/td><td>7.6 min<\/td><td>(75, 30) (79, 30) (110, 30) (129, 30) (166, 30)<\/td><\/tr><tr><td>Group 12<\/td><td>8.4 min<\/td><td>(91, 30) (93, 30) (106, 30) (173, 30)<\/td><\/tr><tr><td>Group 13<\/td><td>9.1 min<\/td><td>(95, 30) (174, 30)<\/td><\/tr><tr><td>Group 14<\/td><td>9.6 min<\/td><td>(111, 30) (146, 30)<\/td><\/tr><tr><td>Group 15<\/td><td>10.5 min<\/td><td>(95, 30) (107, 30) (135, 30)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1<\/strong>\u306b\u3001\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VOC\uff09\u304a\u3088\u3073\u81ed\u6c17\u5316\u5408\u7269\u306e\u5206\u96e2\u7d50\u679c\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff09\u3092\u793a\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u6027\u80fd\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306f<strong>Table VII<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002VOC\u306e\u691c\u91cf\u7dda\u7bc4\u56f2\u306f0.2\uff5e200 ng\/mL\u3001\u81ed\u6c17\u5316\u5408\u7269\u306e\u691c\u91cf\u7dda\u7bc4\u56f2\u306f0.001\uff5e0.256 ng\/mL\u3067\u3057\u305f\u3002\u691c\u91cf\u7dda\u306f\u5404\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3054\u3068\u306b\u8a55\u4fa1\u3055\u308c\u3001\u5316\u5408\u7269\u3054\u3068\u306b\u691c\u91cf\u7dda\u7bc4\u56f2\u304c\u7570\u306a\u308b\u7d50\u679c\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5dee\u7570\u306f\u3001SPME Arrow\u306e\u5438\u7740\u76f8\u5bb9\u91cf\u304a\u3088\u3073\u5316\u5408\u7269\u3054\u3068\u306e\u62bd\u51fa\u7387\u306e\u9055\u3044\u306b\u8d77\u56e0\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u691c\u91cf\u7dda\u306e\u6c7a\u5b9a\u4fc2\u6570\uff08r\u00b2\u5024\uff09\u306b\u3064\u3044\u3066\u306f\u30010.923\uff5e0.999\u306e\u7bc4\u56f2\uff08\u5e73\u57470.998\uff09\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5404\u691c\u91cf\u7dda\u306e\u7cbe\u5ea6\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u3001\u6821\u6b63\u6fc3\u5ea6\u3054\u3068\u306e\u5b9f\u6e2c\u5024\u3068\u691c\u91cf\u7dda\u306e\u4e88\u6e2c\u5024\u3092\u6bd4\u8f03\u3057\u3066\u3001\u76f8\u5bfe\u6a19\u6e96\u8aa4\u5dee\uff08%RSE\uff09\u3092\u7b97\u51fa\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u5168\u4f53\u306e%RSE\u306f2\uff5e27%\uff08\u5e73\u57476%\uff09\u3067\u3042\u308a\u30012\u3064\u306e\u5916\u308c\u5024\u3068\u3057\u3066\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\uff0818%\uff09\u304a\u3088\u30731,4-\u30b8\u30aa\u30ad\u30b5\u30f3\uff0827%\uff09\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u4ed6\u306e\u5316\u5408\u7269\u306e%RSE\u306f2\uff5e10%\u306e\u7bc4\u56f2\u5185\u306b\u53ce\u307e\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u73fe\u6027\u306f\u30017\u56de\u306e\u7e70\u308a\u8fd4\u3057\u6ce8\u5165\u306b\u3088\u308b\u5206\u6790\u304b\u3089\u8a55\u4fa1\u3055\u308c\u3001\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u306f2\uff5e15%\uff08\u5e73\u57474%\uff09\u3067\u3057\u305f\u3002\u3053\u306e\u7d50\u679c\u306f\u3001\u4e00\u822c\u7684\u306a\u30e1\u30bd\u30c3\u30c9\u53d7\u5bb9\u57fa\u6e96\u3067\u3042\u308b\u00b130%\u4ee5\u5185\u3067\u3042\u308a\u3001\u3055\u3089\u306b\u3001\u5404\u5316\u5408\u7269\u306e\u5b9a\u91cf\u9650\u754c\uff08LOQ\uff09\u306f0.0029\uff5e3.033 ng\/mL\uff08ppb\u3001\u5e73\u57470.223 ng\/mL\uff09\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u3068\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">HS-SPME Arrow-GC-MS\u306b\u3088\u308b\u98f2\u6599\u6c34\u4e2d\u306eVOC\u3068\u81ed\u6c17\u5316\u5408\u7269\u306e\u5206\u6790\u3000<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1: <\/strong>HS-SPME Arrow-GC-MS\u306b\u3088\u308b\u98f2\u6599\u6c34\u4e2d\u306eVOC\u3068\u81ed\u6c17\u5316\u5408\u7269\u306e\u5206\u6790<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1517.png\" alt=\"Analysis of VOCs and Odors in Drinking Water via HS-SPME Arrow-GC-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1517<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30608<\/li><li>30614<\/li><li>30030<\/li><li>30026<\/li><li>19915<\/li><li>23280<\/li><li>28903<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Odor compounds<\/li><li>SPME<\/li><li>SPME Arrow<\/li><li>VOCs<\/li><li>drinking water<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1517.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VII:&nbsp;<\/strong>\u30e1\u30bd\u30c3\u30c9\u6027\u80fd<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\u30d4\u30fc\u30af\u756a\u53f7<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\u5316\u5408\u7269<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\u4fdd\u6301\u6642\u9593\uff08\u5206\uff09<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\u691c\u91cf\u7dda\u7bc4\u56f2\u3000 (ng\/mL, ppb)\u3000<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong><span>\u691c\u91cf\u7dda<\/span>\u30d5\u30a3\u30c3\u30c8\u3068\u91cd\u307f\u4ed8\u3051<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>r<sup>2<\/sup><\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\uff05\u76f8\u5bfe\u6a19\u6e96\u8aa4\u5dee<span>&nbsp;<\/span>(%RSE)<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>LOQ<\/strong><\/span><\/th><th class=\"has-text-align-left\" data-align=\"left\"><span><strong>\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u73fe\u6027 (%RSD)<\/strong><\/span><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1<\/td><td class=\"has-text-align-left\" data-align=\"left\">Chlorethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">1.20<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.078<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,1-Dichloroethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">2.07<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.991<\/td><td class=\"has-text-align-left\" data-align=\"left\">9%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.124<\/td><td class=\"has-text-align-left\" data-align=\"left\">6%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">3<\/td><td class=\"has-text-align-left\" data-align=\"left\">Dichloromethane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">2.63<\/td><td class=\"has-text-align-left\" data-align=\"left\">2-200<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">18%<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.033<\/td><td class=\"has-text-align-left\" data-align=\"left\">15%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>trans<\/em>-1,2-Dichloroethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">2.80<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.035<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">5<\/td><td class=\"has-text-align-left\" data-align=\"left\">MTBE<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">2.94<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-10<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.059<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>cis<\/em>-1,2-Dichloroethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">4.15<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.056<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7<\/td><td class=\"has-text-align-left\" data-align=\"left\">Chloroform<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">4.50<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.998<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.063<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">8<\/td><td class=\"has-text-align-left\" data-align=\"left\">Carbon Tetrachloride<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">4.61<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.058<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">9<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,1,1-Trichloroethane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">4.70<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.997<\/td><td class=\"has-text-align-left\" data-align=\"left\">8%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.06<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10<\/td><td class=\"has-text-align-left\" data-align=\"left\">Benzene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">5.18<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-75<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.998<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.004<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">11<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,2-Dichloroethane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">5.46<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.009<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">12<\/td><td class=\"has-text-align-left\" data-align=\"left\">Trichloroethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">5.96<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-75<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.097<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">13<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,2-Dichloropropane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">6.58<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-75<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.996<\/td><td class=\"has-text-align-left\" data-align=\"left\">9%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.05<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">14<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bromodichloromethane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">6.68<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-75<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.05<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">15<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,4-Dioxane<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">6.76<\/td><td class=\"has-text-align-left\" data-align=\"left\">2-200<\/td><td class=\"has-text-align-left\" data-align=\"left\">Linear, 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.923<\/td><td class=\"has-text-align-left\" data-align=\"left\">27%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.895<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">16<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>cis<\/em>-1,3-Dichloropentane<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">7.27<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-200<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.997<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.041<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">17<\/td><td class=\"has-text-align-left\" data-align=\"left\">Toluene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">7.45<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.123<\/td><td class=\"has-text-align-left\" data-align=\"left\">6%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">18<\/td><td class=\"has-text-align-left\" data-align=\"left\">Tetrachloroethene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">7.73<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.042<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">19<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>trans<\/em>-1,3-Dichloropropene<sup>1<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">7.79<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-200<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.997<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.058<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">20<\/td><td class=\"has-text-align-left\" data-align=\"left\">Dibromochloromethane<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">8.01<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.047<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">21<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>m,p<\/em>-Xylene<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">8.63<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.4-20<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.564<\/td><td class=\"has-text-align-left\" data-align=\"left\">14%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">22<\/td><td class=\"has-text-align-left\" data-align=\"left\"><em>o<\/em>-Xylene<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">8.89<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-10<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.139<\/td><td class=\"has-text-align-left\" data-align=\"left\">7%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">23<\/td><td class=\"has-text-align-left\" data-align=\"left\">Bromoform<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">8.94<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-75<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.998<\/td><td class=\"has-text-align-left\" data-align=\"left\">4%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.056<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">24<\/td><td class=\"has-text-align-left\" data-align=\"left\">1,2-Dichlorobenzene<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">9.89<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2-25<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.999<\/td><td class=\"has-text-align-left\" data-align=\"left\">2%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.045<\/td><td class=\"has-text-align-left\" data-align=\"left\">3%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">25<\/td><td class=\"has-text-align-left\" data-align=\"left\">2-Methylisoborneol<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">11.07<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.004-0.256<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.997<\/td><td class=\"has-text-align-left\" data-align=\"left\">10%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.005<\/td><td class=\"has-text-align-left\" data-align=\"left\">9%<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">26<\/td><td class=\"has-text-align-left\" data-align=\"left\">Geosmin<sup>3<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">12.17<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.004-0.256<\/td><td class=\"has-text-align-left\" data-align=\"left\">Quad., 1\/x<sup>2<\/sup><\/td><td class=\"has-text-align-left\" data-align=\"left\">0.996<\/td><td class=\"has-text-align-left\" data-align=\"left\">10%<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.003<\/td><td class=\"has-text-align-left\" data-align=\"left\">5%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">ISTD\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9-\u30d5\u30eb\u30aa\u30ed\u30d9\u30f3\u30bc\u30f3<sup>1<\/sup>\u30011,4-\u30b8\u30aa\u30ad\u30b5\u30f3-d8<sup>2<\/sup>\u3001p-\u30d6\u30ed\u30e2\u30d5\u30eb\u30aa\u30ed\u30d9\u30f3\u30bc\u30f3<sup>3<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">HS-SPME Arrow-GC-MS\u306f\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VOC\uff09\u304a\u3088\u3073\u81ed\u6c17\u5316\u5408\u7269\u3092\u7c21\u4fbf\u306b\u5b9a\u91cf\u3067\u304d\u308b\u624b\u6cd5\u3067\u3059\u3002\u672c\u7814\u7a76\u306e\u7d50\u679c\u304b\u3089\u3001SPME Arrow\u304c\u3055\u307e\u3056\u307e\u306a\u5316\u5408\u7269\u3092\u591a\u69d8\u306a\u691c\u51fa\u9650\u754c\u3067\u5b9a\u91cf\u3067\u304d\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u7279\u306b\u3001\u81ed\u6c17\u5316\u5408\u7269\u306f\u5146\u5206\u7387\uff08ppt\uff09\u30ec\u30d9\u30eb\u3068\u3044\u3046\u6975\u3081\u3066\u4f4e\u6fc3\u5ea6\u3067\u691c\u51fa\u53ef\u80fd\u3067\u3042\u308a\u3001\u672c\u624b\u6cd5\u304c\u98f2\u6599\u6c34\u4e2d\u306e\u81ed\u6c17\u5316\u5408\u7269\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306e\u6709\u52b9\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u304a\u3088\u3073\u5206\u6790\u624b\u6cd5\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001\u4eca\u5f8c\u306e\u8ab2\u984c\u3068\u3057\u3066\u3001MIB\u304a\u3088\u3073\u30b8\u30a7\u30aa\u30b9\u30df\u30f3\u306b\u5bfe\u3057\u3066\u3001\u3088\u308a\u9069\u5207\u306a\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08ISTD\uff09\u306e\u9078\u5b9a\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References\u3000\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Cobb County-Marietta Water Authority (CCMWA), Geosmin and methyl-Isoborneol (MIB), online article, 2023. https:\/\/www.ccmwa.org\/education\/geosmin-and-methyl-isoborneol-mib<\/li>\n\n\n\n<li>United States Environmental Protection Agency (U.S. EPA), Definition and procedure for the determination of the method detection limit, revision 2, December 2016. https:\/\/www.epa.gov\/sites\/default\/files\/2016-12\/documents\/mdl-procedure_rev2_12-13-2016.pdf<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30608\">                                \u30ab\u30bf\u30ed\u30b0No. 30608                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Drinking Water Odor Standard &#8211; Geosmin and 2-Methylisoborneol, 100 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30608\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30030\">                                \u30ab\u30bf\u30ed\u30b0No. 30030                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Fluorobenzene, 2000 \u00b5g\/mL, P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30030\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30614\">                                \u30ab\u30bf\u30ed\u30b0No. 30614                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">1,4-Dioxane-d8 Standard, 2000 \u00b5g\/mL, P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30614\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30026\">                                \u30ab\u30bf\u30ed\u30b0No. 30026                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">4-Bromofluorobenzene (BFB) Standard, 2000 \u00b5g\/mL, P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30026\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28903-1\">                                \u30ab\u30bf\u30ed\u30b0No. 28903-1                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PAL Smart SPME Arrow 1.10 mm: \u30ab\u30fc\u30dc\u30f3-WR\/PDMS, \u819c\u539a 120 \u00b5m, \u819c\u9577 20 mm, Light Blue<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28903-1\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19915\">                                \u30ab\u30bf\u30ed\u30b0No. 19915                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-VMS GC Capillary Column, 30 m, 0.25 mm ID, 1.40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19915\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23280\">                                \u30ab\u30bf\u30ed\u30b0No. 23280                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Straight\/SPME Inlet Liner, 1.8 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23280\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u672c\u7814\u7a76\u3067\u306f\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VOCs\uff09\u304a\u3088\u3073\u81ed\u6c17\u7269\u8cea\u306e\u52b9\u7387\u7684\u306a\u5b9a\u91cf\u5206\u6790\u624b\u6cd5\u3092\u63d0\u6848\u3057\u307e\u3059\u3002HS-SPME-GC-MS\u6cd5\u3092\u7528\u3044\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3055\u305b\u3001\u4f4e\u6fc3\u5ea6\u3067\u306e\u691c\u51fa\u304c\u53ef\u80fd\u306b\u3002\u30e1\u30c1\u30eb\u30a4\u30bd\u30dc\u30eb\u30cd\u30aa\u30fc\u30eb\uff08MIB\uff09\u3084\u30b8\u30a7\u30aa\u30b9\u30df\u30f3\u3092\u542b\u3080\u81ed\u6c17\u7269\u8cea\u306e\u6e2c\u5b9a\u306b\u304a\u3051\u308b\u65b0\u305f\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u89e3\u8aac\u3002<\/p>\n","protected":false},"author":32,"featured_media":6559,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[2751],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[452,645],"class_list":["post-45323","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","industries-application-semivolatiles"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"industries-application":[{"value":2751,"label":"Semivolatiles"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN4283-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Colton Myers","author_link":"https:\/\/discover.restek.com\/ja\/author\/colton-myers\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."},{"term_id":645,"user_id":0,"is_guest":1,"slug":"anyssa-coverston","display_name":"Anyssa Coverston","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-coverston-anyssa.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-coverston-anyssa.jpg"},"author_category":"1","first_name":"Anyssa","last_name":"Coverston","user_url":"https:\/\/www.linkedin.com\/in\/anyssa-coverston\/","job_title":"Advanced Scientist: Reference Standards New Product Development","description":"<p>Anyssa Coverston is an advanced scientist specializing in reference standards new product development. She holds a BS in forensic chemistry from the University of Central Florida and an MPS in forensic chemistry with a research focus in forensic biology from The Pennsylvania State University.<\/p>\r\n\r\n<p>She began her career as a fingerprint analyst with the Miami-Dade Police Department's Forensic Services Bureau, where she spent three and a half years supporting criminal investigations through forensic analysis.<\/p>\r\n\r\n<p>After joining Restek, Anyssa worked as a quality control technician for GC columns, gaining valuable experience in quality assurance and laboratory testing. She later transitioned into her current role as an advanced R&amp;D scientist in the reference standards new product development department, where she develops high-quality reference standards that support scientists and laboratories across a wide range of industries.<\/p>"}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45323"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45323\/revisions"}],"predecessor-version":[{"id":79255,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45323\/revisions\/79255"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6559"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45323"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45323"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45323"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45323"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45323"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45323"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45323"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45323"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}