{"id":45324,"date":"2021-03-22T00:00:00","date_gmt":"2021-03-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-an-introduction-to-low-pressure-gc-ms-lpgc-ms\/"},"modified":"2025-11-25T21:38:48","modified_gmt":"2025-11-25T21:38:48","slug":"japanese-an-introduction-to-low-pressure-gc-ms-lpgc-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3505-ja\/japanese-an-introduction-to-low-pressure-gc-ms-lpgc-ms","title":{"rendered":"Low-Pressure GC-MS (LPGC-MS)\u306e\u6982\u8981"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u5f93\u6765\u306eGC-MS\u3088\u308a\u6700\u59273.3\u500d\u3001\u5206\u6790\u3092\u9ad8\u901f\u5316<\/li>\n\n\n\n<li>\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3092\u6700\u592781\uff05\u524a\u6e1b\u3057\u3001\u30b3\u30b9\u30c8\u3092\u5927\u5e45\u306b\u7bc0\u7d04<\/li>\n\n\n\n<li>\u88fd\u9020\u5143\u3067\u63a5\u7d9a\u3059\u308b\u30ea\u30fc\u30af\u306e\u306a\u3044\u30ad\u30c3\u30c8\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u4ea4\u63db\u3068\u540c\u3058\u304f\u3089\u3044\u7c21\u5358\u306a\u30ab\u30e9\u30e0\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7<\/li>\n\n\n\n<li>\u9ad8\u901fGC-MS\u304a\u3088\u3073GC-MS\/MS\u6cd5\u306b\u6700\u9069<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092GC\u306e\u691c\u51fa\u5668\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u3001\u5316\u5408\u7269\u306e\u540c\u5b9a\u3084\u5b9a\u91cf\u306b\u304a\u3044\u3066\u591a\u304f\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001GC-MS\u306e\u771f\u7a7a\u3092\u5229\u7528\u3057\u3066\u30ab\u30e9\u30e0\u5185\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u4fdd\u3064\u3068\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u306e\u9ad8\u901f\u5316\u304c\u3067\u304d\u308b\u3068\u3044\u3046\u5229\u70b9\u306b\u3064\u3044\u3066\u306f\u3001\u672a\u3060\u5341\u5206\u306b\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u3068\u3044\u3046\u306e\u3082\u3001\u5f93\u6765\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3067\u306f\u3001\u30ab\u30e9\u30e0\u51fa\u53e3\u5074\u672b\u7aef\u306e\u6570\u30e1\u30fc\u30c8\u30eb\u7a0b\u5ea6\u3057\u304b\u771f\u7a7a\u306b\u4fdd\u3064\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u3092\u771f\u7a7a\u306b\u4fdd\u3064\u3053\u3068\u304c\u5fc5\u8981\u306aLPGC-MS\u306e\u5b9f\u73fe\u306f\u6975\u3081\u3066\u56f0\u96e3\u3067\u3042\u308b\u3053\u3068\u304c\u7406\u7531\u3060\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u3067\u306f\u3001LPGC-MS\u306f\u5b9f\u969b\u306e\u30e9\u30dc\u3067\u5b9f\u73fe\u304c\u96e3\u3057\u3044\u673a\u4e0a\u306e\u7a7a\u8ad6\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u7b54\u3048\u306f\u300c\u3044\u3044\u3048\u300d\u3067\u3059\u3002\u5b9f\u306f\u3001LPGC-MS\u306b\u9069\u3057\u305f\u30ab\u30e9\u30e0\u3092\u73fe\u5728\u306e\u30b7\u30b9\u30c6\u30e0\u306b\u63a5\u7d9a\u3059\u308c\u3070\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306e\u5185\u5727\u3092\u771f\u7a7a\u306b\u4fdd\u3064\u3053\u3068\u304c\u53ef\u80fd\u3067\u3001GC-MS\u30e6\u30fc\u30b6\u30fc\u304c\u8ab0\u3067\u3082\u7c21\u5358\u306bLPGC-MS\u306e\u6069\u6075\u3092\u4eab\u53d7\u3067\u304d\u308b\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Low-pressure GC-MS (LPGC-MS)\u306f\u3001\u5206\u6790\u3092\u5927\u5e45\u306b\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u624b\u6cd5\u3067\u3059\u3002MS\u306e\u771f\u7a7a\u30b7\u30b9\u30c6\u30e0\u3068LPGC-MS\u7528\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u30ab\u30e9\u30e0\u5185\u5727\u3092\u771f\u7a7a\u306b\u4fdd\u3064\u3053\u3068\u306b\u3088\u3063\u3066\u3053\u308c\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u3001LPGC-MS\u3067\u306f\u30d8\u30ea\u30a6\u30e0\u6d88\u8cbb\u91cf\u3092\u5287\u7684\u306b\u524a\u6e1b\u3067\u304d\u308b\u306e\u3067\u3001\u30b3\u30b9\u30c8\u30ab\u30c3\u30c8\u3082\u5b9f\u73fe\u3057\u307e\u3059\u3002\u3067\u306f\u3001LPGC-MS\u3092\u6d3b\u7528\u3059\u308b\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u30b7\u30b9\u30c6\u30e0\u69cb\u6210\u304c\u5fc5\u8981\u306b\u306a\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u5b9f\u306f\u3068\u3066\u3082\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u3002MS\u5074\u306b0.53mm\u307e\u305f\u306f0.32mm\u5185\u5f84\u306e\u77ed\u3044\u5206\u6790\u30ab\u30e9\u30e0\u3092\u3001\u307e\u305f\u3001GC\u6ce8\u5165\u53e3\u5074\u306b\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u3092\u63a5\u7d9a\u3059\u308b\u3060\u3051\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u30ab\u30e9\u30e0\u5168\u4f53\u304c\u771f\u7a7a\u306b\u4fdd\u305f\u308c\u3001LPGC-MS\u306e\u6069\u6075\u3092\u53d7\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002LPGC-MS\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5185\u5727\u3092\u771f\u7a7a\u306b\u4fdd\u3064\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u30ab\u30e9\u30e0\u9577\u306f10\uff5e15m\u7a0b\u5ea6\u3068\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u30ab\u30e9\u30e0\u306e\u7406\u8ad6\u6bb5\u6570\u306f\u4f4e\u4e0b\u3059\u308b\u306e\u3067\u3059\u304c\u3001\u5206\u6790\u306e\u9ad8\u901f\u5316\u3068\u6d88\u8cbb\u30ac\u30b9\u306e\u5927\u5e45\u306a\u7bc0\u7d04\u3068\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u3053\u3068\u304b\u3089\u3001\u76ee\u7684\u306b\u3088\u3063\u3066\u306f\u6975\u3081\u3066\u9b45\u529b\u7684\u306a\u624b\u6cd5\u3068\u306a\u308b\u3067\u3057\u3087\u3046\u3002\u3061\u306a\u307f\u306b\u3001\u30ab\u30e9\u30e0\u306e\u7406\u8ad6\u6bb5\u6570\u306b\u8d77\u56e0\u3057\u3066\u6210\u5206\u306e\u5171\u6eb6\u51fa\u304c\u767a\u751f\u3057\u3066\u3082\u3001LPGC-MS\u306f\u8cea\u91cf\u5206\u6790\u8a08\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u30c7\u30b3\u30f3\u30dc\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u6d3b\u7528\u3057\u3066\u52b9\u679c\u7684\u306b\u6210\u5206\u306e\u5206\u96e2\u304c\u3067\u304d\u308c\u3070\u5206\u96e2\u554f\u984c\u306e\u5f71\u97ff\u306f\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1<\/strong>\u3068<strong>Table I<\/strong>\u306b\u5f93\u6765\u306eGC-MS\u3068\u306e\u3068LPGC-MS\u306e\u6bd4\u8f03\u3092\u793a\u3057\u307e\u3057\u305f\u3002GC\u30ab\u30e9\u30e0\u5185\u3092\u771f\u7a7a\u306b\u4fdd\u3064\u3053\u3068\u3067\u3001\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u3060\u3051\u3067\u306a\u304f\u3001\u611f\u5ea6\u306b\u3064\u3044\u3066\u3082\u6539\u5584\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u305d\u308c\u3067\u306f\u3001\u300cVacuum-outlet GC\u300d\u3001\u307e\u305f\u306f\u300cLow-Pressure GC-MS\uff08LPGC-MS\uff09\u300d\u3068\u3057\u3066\u77e5\u3089\u308c\u3066\u3044\u308b\u3053\u306e\u6280\u8853\u306b\u3064\u3044\u3066\u3001\u3055\u3089\u306b\u8a73\u3057\u304f\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1<\/strong>: \u98df\u54c1\u4e2d\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u3067\u306f\u3001LPGC-MS\u3092\u7528\u3044\u305f\u5834\u5408\u3001\u5f93\u6765\u6cd5\u3068\u6bd4\u8f03\u3057\u3066\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u306f3.3\u500d\u9ad8\u901f\u5316\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u306f54%\u524a\u6e1b\u53ef\u80fd\u3002\u30ab\u30e9\u30e0\u52b9\u7387\u306f\u4f4e\u3044\u3082\u306e\u306e\u3001\u7dda\u901f\u5ea6\u304c\u901f\u304f\u306a\u308b\u3053\u3068\u3067\u30d4\u30fc\u30af\u5e45\u304c\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308a\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u6539\u5584\u3055\u308c\u308b\u305f\u3081\u3001\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u3066\u3044\u308b\u3002\u307e\u305f\u3001MS\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u306e\u3067\u30d4\u30fc\u30af\u304c\u5bc6\u63a5\u3057\u3066\u6eb6\u51fa\u3057\u3066\u3082\u3001\u30b9\u30da\u30af\u30c8\u30eb\u5206\u96e2\u304c\u53ef\u80fd\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\uff08\u82f1\u6587\uff09\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0573.png\" alt=\"Comparison of Conventional vs. LPGC-MS Pesticides Analysis\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0573<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32564<\/li><li>32568<\/li><li>23444<\/li><li>32562<\/li><li>13423<\/li><li>11800<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>LPGC<\/li><li>Pesticide<\/li><li>multiresidue<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0573.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">LPGC-MS\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306fRestek\u306eResource Hub\u3067\u691c\u7d22\uff01<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u5f93\u6765\u306eGC-MS\u6cd5\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001LPGC\u306f\u9855\u8457\u306a\u5206\u6790\u306e\u9ad8\u901f\u5316\u306b\u52a0\u3048\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u524a\u6e1b\u306b\u3088\u308b\u30b3\u30b9\u30c8\u30bb\u30fc\u30d3\u30f3\u30b0\u304c\u53ef\u80fd<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\"><strong>Application<\/strong><\/td><td rowspan=\"2\"><strong>Column Kit<\/strong><\/td><td colspan=\"2\"><strong>LPGC-MS\u306e\u30e1\u30ea\u30c3\u30c8<\/strong><\/td><\/tr><tr><td><strong>\u5206\u6790\u306e\u9ad8\u901f\u5316<\/strong><\/td><td><strong>He\u4f7f\u7528\u91cf\u524a\u6e1b\u7387<\/strong><\/td><\/tr><tr><td>Alkylfurans<\/td><td>LPGC Rxi-624Sil MS, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11804\" target=\"_blank\" rel=\"noopener\">cat. #11804<\/a>)<\/td><td>2.3x faster<\/td><td>72% less<\/td><\/tr><tr><td>Arylamines<\/td><td>LPGC Rxi-35Sil MS, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11806\" target=\"_blank\" rel=\"noopener\">cat.# 11806<\/a>)<\/td><td>3.3x faster<\/td><td>81% less<\/td><\/tr><tr><td>MCPDs<\/td><td>LPGC Rxi-17Sil MS, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11805\" target=\"_blank\" rel=\"noopener\">cat.# 11805<\/a>)<\/td><td>2.0x faster<\/td><td>69% less<\/td><\/tr><tr><td rowspan=\"2\">Nitrosamines<\/td><td>LPGC Rxi-624Sil MS, 15 m (<a href=\"https:\/\/www.restek.com\/p\/11803\" target=\"_blank\" rel=\"noopener\">cat.# 11803<\/a>)<\/td><td>1.8x faster<\/td><td>29% less<\/td><\/tr><tr><td>LPGC Rxi-624Sil MS, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11804\" target=\"_blank\" rel=\"noopener\">cat.# 11804<\/a>)<\/td><td>2.3x faster<\/td><td>67% less<\/td><\/tr><tr><td rowspan=\"2\">Pesticides<\/td><td>LPGC Rtx-5ms, 15 m (<a href=\"https:\/\/www.restek.com\/p\/11800\" target=\"_blank\" rel=\"noopener\">cat.# 11800<\/a>)<\/td><td>3.1x faster<\/td><td>54% less<\/td><\/tr><tr><td>LPGC Rtx-5ms, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11802\" target=\"_blank\" rel=\"noopener\">cat.# 11802<\/a>)<\/td><td>3.3x faster<\/td><td>76% less<\/td><\/tr><tr><td>Phthalates<\/td><td>LPGC Rxi-35Sil MS, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11806\" target=\"_blank\" rel=\"noopener\">cat.# 11806<\/a>)<\/td><td>1.4x faster<\/td><td>67% less<\/td><\/tr><tr><td>PFAS (Fluorotelomer Alcohols)<\/td><td>LPGC Rtx-200, 10 m (<a href=\"https:\/\/www.restek.com\/p\/11807\" target=\"_blank\" rel=\"noopener\">cat.# 11807<\/a>)<\/td><td>1.9x faster<\/td><td>60% less<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u9ad8\u901fGC-MS\u306a\u3089LPGC-MS\u3092\u9078\u307c\u3046\uff01<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u306f\u3001\u5206\u6790\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3057\u306a\u304c\u3089\u3001MS\u30c7\u30fc\u30bf\u53d6\u5f97\u306b\u5fc5\u8981\u306a\u30d4\u30fc\u30af\u5e45\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u9ad8\u901fGC-MS\u3068\u3057\u3066\u3082\u3063\u3068\u3082\u52b9\u679c\u7684\u306a\u9078\u629e\u80a2\u3067\u3059\u3002\u901a\u5e38\u3001MS\u5206\u6790\u3067\u306f30 m x 0.25 mm ID\u30ab\u30e9\u30e0\u304c\u4f7f\u7528\u3055\u308c\u3001\u7d04120,000\u306e\u7406\u8ad6\u6bb5\u6570\u3092\u6301\u3061\u307e\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u3082\u9069\u5207\u306a\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u3001MS\u306e\u771f\u7a7a\u30b7\u30b9\u30c6\u30e0\u3068\u6ce8\u5165\u53e3\u306e\u30d8\u30c3\u30c9\u5727\u3092\u5b89\u5b9a\u3055\u305b\u3001\u5206\u6790\u611f\u5ea6\u3084\u7cbe\u5ea6\u3092\u4fdd\u3061\u306a\u304c\u3089\u591a\u5c11\u306e\u5206\u6790\u9ad8\u901f\u5316\u306f\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001\u77ed\u30440.53 mm\u307e\u305f\u306f0.32 mm ID\u306e\u5206\u6790\u30ab\u30e9\u30e0\u3068\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3067\u69cb\u6210\u3055\u308c\u305f\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u7406\u8ad6\u6bb5\u6570\u306f\u7d0430,000\u3001\u5206\u6790\u6642\u306e\u6d41\u91cf\u306f2 mL\/min\u7a0b\u5ea6\u3067\u904b\u7528\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3068\u5206\u6790\u30ab\u30e9\u30e0\u5185\u304c\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u72b6\u614b\u3068\u306a\u308b\u305f\u3081\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6700\u9069\u7dda\u901f\u5ea6\u304c\u5927\u304d\u304f\u6539\u5584\u3057\u3001\u5f93\u6765\u306e30 m x 0.25 mm\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u5206\u6790\u6642\u9593\u3092\u6700\u59273.3\u500d\u9ad8\u901f\u5316\u3067\u304d\u307e\u3059\u3002\u30d4\u30fc\u30af\u5e45\u30821.5\uff5e2\u79d2\u3068\u3001MS\u30c7\u30fc\u30bf\u53d6\u5f97\u306b\u5341\u5206\u306a\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u3092\u78ba\u4fdd\u3067\u304d\u3001\u30ab\u30e9\u30e0\u5185\u5f84\u304c0.53 mm\u304a\u3088\u30730.32 mm\u3068\u592a\u3044\u306e\u3067\u3001\u7d30\u5f84\u30ab\u30e9\u30e0\u306b\u6bd4\u3079\u3066\u8a66\u6599\u5c0e\u5165\u91cf\u3092\u5897\u3084\u305b\u308b\u3001\u3068\u3044\u3046\u5229\u70b9\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u4ee5\u5916\u306b\u3082\u5206\u6790\u901f\u5ea6\u3092\u4e0a\u3052\u308b\u65b9\u6cd5\u306f\u3042\u308b\u306e\u3067\u3059\u304c\u3001\u305d\u308c\u3089\u306e\u65b9\u6cd5\u306b\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u8ab2\u984c\u304c\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u77ed\u304f\u3066\u7d30\u3044\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b<br><\/strong>10 m x 0.10 mm\u306e\u30ab\u30e9\u30e0\u306f\u300130 m x 0.25 mm\u30ab\u30e9\u30e0\u3068\u540c\u7b49\u306e\u30ab\u30e9\u30e0\u52b9\u7387\uff08\u7406\u8ad6\u6bb5\u6570\uff09\u3068\u5206\u96e2\u80fd\u304c\u5f97\u3089\u308c\u307e\u3059\u304c\u3001\u5185\u5f84\u304c\u7d30\u304f\u8a66\u6599\u5c0e\u5165\u91cf\u304c\u5c0f\u3055\u3044\u306e\u3067\u3001\u540c\u91cf\u306e\u8a66\u6599\u3092\u6ce8\u5165\u3059\u308b\u3068\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u30c8\u30e9\u30d6\u30eb\uff08\u4f8b\u3048\u3070\u3001\u300c\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u300d\uff09\u304c\u767a\u751f\u3057\u307e\u3059\u3002\u30d4\u30fc\u30af\u5f62\u72b6\u30c8\u30e9\u30d6\u30eb\u3092\u56de\u907f\u3059\u308b\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6fc3\u5ea6\u3092\u4f4e\u304f\u3059\u308b\u304b\u3001\u307e\u305f\u306f\u6ce8\u5165\u91cf\u3092\u5927\u5e45\u306b\u6e1b\u3089\u3059\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3001\u611f\u5ea6\u3068\u3044\u3046\u70b9\u3067\u554f\u984c\u304c\u6b8b\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u9ad8\u6d41\u91cf\u306730 m x 0.25 mm\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b<br><\/strong>\u6d41\u91cf\u306e\u5897\u52a0\u306f\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u305f\u3081\u306e\u6700\u3082\u7c21\u5358\u306a\u65b9\u6cd5\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u5206\u6790\u6642\u9593\u30921\/3\u306b\u77ed\u7e2e\u3057\u305f\u3044\u5834\u5408\u3001\u6d41\u91cf\u306f\u7d0412 mL\/min\u7a0b\u5ea6\u3001\u6ce8\u5165\u53e3\u5727\u306f\u7d0463 psi\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u6761\u4ef6\u3067\u306f\u3001\u6ce8\u5165\u3001MS\u306e\u30c7\u30fc\u30bf\u53d6\u308a\u8fbc\u307f\u901f\u5ea6\u3001\u304a\u3088\u3073MS\u306e\u30bf\u30fc\u30dc\u30dd\u30f3\u30d7\u5bb9\u91cf\u306b\u554f\u984c\u304c\u751f\u3058\u308b\u305f\u3081\u3001\u73fe\u5b9f\u7684\u306a\u904b\u7528\u306f\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>10 m x 0.25 mm\u30ab\u30e9\u30e0\u3092\u6700\u9069\u306a\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u6d41\u91cf\u3067\u4f7f\u7528\u3059\u308b<br><\/strong>\u3053\u306e\u65b9\u6cd5\u3067\u306f3\uff5e4\u500d\u306e\u5206\u6790\u9ad8\u901f\u5316\u3092\u671f\u5f85\u3067\u304d\u307e\u3059\u304c\u3001\u5fc5\u8981\u306a\u6ce8\u5165\u53e3\u5727\u306f\u7d040.35 psi\u3068\u975e\u5e38\u306b\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3084\u3001\u5727\u529b\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u30ab\u30e9\u30e0\u306e\u30c8\u30ea\u30df\u30f3\u30b0\u304c\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30d4\u30fc\u30af\u5e45\u304c\u975e\u5e38\u306b\u72ed\u304f\u306a\u308b\u305f\u3081\u3001MS\u306e\u30c7\u30fc\u30bf\u53d6\u308a\u8fbc\u307f\u306b\u5341\u5206\u306a\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u3092\u78ba\u4fdd\u3067\u304d\u306a\u3044\u3068\u3044\u3046\u554f\u984c\u3082\u751f\u3058\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306b\u3001LPGC-MS\u306f\u4ed6\u306e\u65b9\u6cd5\u306b\u6bd4\u3079\u3066\u3001\u5206\u6790\u901f\u5ea6\u3001\u30d4\u30fc\u30af\u5e45\u306e\u5236\u5fa1\u3001\u8a66\u6599\u5c0e\u5165\u91cf\u306e\u70b9\u3067\u30d0\u30e9\u30f3\u30b9\u304c\u826f\u304f\u3001\u7279\u306bMS\u30c7\u30fc\u30bf\u53d6\u5f97\u306b\u304a\u3044\u3066\u9ad8\u3044\u4fe1\u983c\u6027\u3092\u63d0\u4f9b\u3059\u308b\u305f\u3081\u3001\u512a\u308c\u305f\u9078\u629e\u80a2\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LPGC-MS\u306f\u3069\u306e\u3088\u3046\u306b\u5206\u6790\u3092\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u3055\u305b\u308b\u306e\u304b?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u300c\u4f4e\u5727\u300d\u3068\u3044\u3046\u6982\u5ff5\u3053\u305d\u304cLPGC-MS\u306e\u5229\u70b9\u306e\u6838\u5fc3\u3067\u3059\u3002\u4f4e\u5727\u306e\u91cd\u8981\u6027\u3092\u7406\u89e3\u3059\u308b\u305f\u3081\u306b\u3001\u30ab\u30e9\u30e0\u306e\u300c\u6700\u9069\u7dda\u901f\u5ea6\u300d\u304b\u3089\u8a71\u3092\u59cb\u3081\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3044\u305a\u308c\u306eGC\u30ab\u30e9\u30e0\u306b\u3082\u3001\u6700\u3082\u52b9\u7387\u7684\u306a\u5206\u96e2\u3092\u751f\u307f\u51fa\u3059\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u300c\u6700\u9069\u7dda\u901f\u5ea6\u300d\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u6700\u9069\u7dda\u901f\u5ea6\u306b\u5bfe\u3057\u3066\u3001\u4f7f\u7528\u3059\u308b\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7dda\u901f\u5ea6\u304c\u4f4e\u3044\u3068\u3001\u30d4\u30fc\u30af\u304c\u5e83\u304c\u308a\u3001\u5206\u96e2\u5ea6\u304c\u4f4e\u304f\u306a\u308a\u307e\u3059\u3002\u9006\u306b\u7dda\u901f\u5ea6\u304c\u9ad8\u3044\u3068\u3001\u6210\u5206\u3068\u30ab\u30e9\u30e0\u56fa\u5b9a\u76f8\u306e\u76f8\u4e92\u4f5c\u7528\u306b\u5fc5\u8981\u306a\u6642\u9593\u304c\u53d6\u308c\u305a\u3001\u5206\u96e2\u304c\u60aa\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001GC\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u5341\u5206\u306b\u5f15\u304d\u51fa\u3059\u305f\u3081\u306b\u306f\u4f7f\u7528\u30ab\u30e9\u30e0\u306e\u6700\u9069\u7dda\u901f\u5ea6\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u975e\u5e38\u306b\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u306f\u6700\u9069\u7dda\u901f\u5ea6\u3068\u306f\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u304c\u540c\u3058\u3067\u3042\u308c\u3070\u5e38\u306b\u4e00\u5b9a\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u7b54\u3048\u306f\u300c\u3044\u3044\u3048\u300d\u3067\u3059\u3002\u6700\u9069\u7dda\u901f\u5ea6\u306b\u95a2\u4fc2\u3059\u308b\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u30ab\u30e9\u30e0\u5727\u529b\u304c\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u306a\u308b\u3068\u6700\u9069\u7dda\u901f\u5ea6\u306f\u9ad8\u304f\u306a\u308b<\/li>\n\n\n\n<li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7c98\u6027\u304c\u4e0b\u304c\u308b\u3068\u6700\u9069\u7dda\u901f\u5ea6\u306f\u9ad8\u304f\u306a\u308b<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u5727\u529b\u304c\u4f4e\u5727\u306b\u306a\u308b\u3068\u30ad\u30e3\u30ea\u30a2\u2015\u30ac\u30b9\u306e\u7c98\u6027\u304c\u4e0b\u304c\u308b<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u3064\u307e\u308a\u3001GC\u30ab\u30e9\u30e0\u5727\u529b\u304c\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u306a\u308b\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u7c98\u6027\u304c\u4f4e\u4e0b\u3057\u3001\u6700\u9069\u7dda\u901f\u5ea6\u306f\u9ad8\u304f\u306a\u308b\u305f\u3081\uff08<strong>Figure 2<\/strong>\uff09\u3001\u5206\u6790\u3092\u9ad8\u901f\u5316\u3057\u3066\u3082\u5206\u96e2\u3092\u640d\u306a\u3046\u3053\u3068\u304c\u306a\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2<\/strong>: \u7570\u306a\u308b\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u5185\u5727\u306eVan Deemter\u30d7\u30ed\u30c3\u30c8\uff1a\u4f4e\u5727\u6761\u4ef6\u306e0.53 mm ID\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6700\u3082\u4f4e\u3044HETP\u3068\u306a\u308b\u6700\u5927\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u3001\u3088\u308a\u9ad8\u3044\u7dda\u901f\u5ea6\u3067\u9054\u6210\u3055\u308c\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u308b\uff08HETP\uff1d\u7406\u8ad6\u6bb5\u9ad8\u3055\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"700\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/39-2-T-figure-article-GNAR3505B-02-1024x700.jpg\" alt=\"\" class=\"wp-image-11733\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/39-2-T-figure-article-GNAR3505B-02-1024x700.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-2-T-figure-article-GNAR3505B-02-300x205.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-2-T-figure-article-GNAR3505B-02-768x525.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-2-T-figure-article-GNAR3505B-02-1536x1050.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-2-T-figure-article-GNAR3505B-02-2048x1400.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u304b\u3057\u3001GC\u30ab\u30e9\u30e0\u5168\u9577\u306b\u308f\u305f\u3063\u3066\u5727\u529b\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u4fdd\u3064\u3053\u3068\u306f\u5bb9\u6613\u306a\u3053\u3068\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u7279\u306bGC-MS\u5206\u6790\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\uff08\u4f8b\u3048\u3070\u300130m\u00d7\uff10.25m\uff09\u306b\u304a\u3044\u3066\u306f\u4e0d\u53ef\u80fd\u3068\u8a00\u3063\u3066\u826f\u3044\u3067\u3057\u3087\u3046\u3002\u6b21\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u306f\u3001GC\u30ab\u30e9\u30e0\u5168\u4f53\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u4fdd\u3064\u5834\u5408\u306b\u8d77\u3053\u308a\u5f97\u308b\u554f\u984c\u3068\u3001\u305d\u308c\u306b\u5bfe\u3059\u308b\u89e3\u6c7a\u7b56\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5206\u96e2\u52b9\u7387\u3068\u3001LPGC-MS\u306e\u5927\u5e45\u306a\u901f\u5ea6\u5411\u4e0a\u304a\u3088\u3073\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u306e\u524a\u6e1b\u3001\u3068\u3044\u30463\u3064\u306e\u30d0\u30e9\u30f3\u30b9\u3092\u4fdd\u3064\u306b\u306f\u3069\u3046\u3057\u305f\u3089\u3088\u3044\u304b\u3001\u3068\u3044\u3046\u70b9\u306b\u3064\u3044\u3066\u3082\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a73\u7d30\u306f\u3053\u306e\u5f8c\u8ff0\u3079\u307e\u3059\u304c\u3001\u5185\u5f84\u304c0.53 mm\u307e\u305f\u306f0.32 mm\u306e\u6bd4\u8f03\u7684\u77ed\u3044GC\u30ab\u30e9\u30e0\u3092MS\u306b\u63a5\u7d9a\u3059\u308c\u3070\u3001MS\u306e\u771f\u7a7a\u30dd\u30f3\u30d7\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u5185\u3092\u4f4e\u5727\u306b\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u30ab\u30e9\u30e0\u9577\u304c\u77ed\u304f\u5185\u5f84\u306e\u592a\u3044\u30ab\u30e9\u30e0\u306f\u3001\u30ab\u30e9\u30e0\u9577\u304c\u9577\u304f\u5185\u5f84\u306e\u7d30\u3044\u30ab\u30e9\u30e0\u306b\u6bd4\u3079\u3066\u7406\u8ad6\u6bb5\u6570\uff08\u30ab\u30e9\u30e0\u52b9\u7387\u306e\u5c3a\u5ea6\uff09\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u3064\u307e\u308a\u3001LPGC-MS\u30ab\u30e9\u30e0\u3067\u306f\u3001\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308bGC-MS\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u6027\u80fd\u3092\u4e0a\u56de\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001LPGC-MS\u3067\u306f\u8cea\u91cf\u5206\u6790\u8a08\u3067\u5f97\u3089\u308c\u305fMS\u30b9\u30da\u30af\u30c8\u30eb\u3092\u7528\u3044\u305fMS\u5206\u96e2\u306b\u3088\u3063\u3066\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u3092\u88dc\u3046\u3068\u3044\u3046\u70b9\u3082\u91cd\u8981\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u9577\u5e74\u306e\u8ab2\u984c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Low-pressure GC\u306e\u6b74\u53f2\u306f\u53e4\u304f\u30011960\u5e74\u4ee3\u306b\u306f\u6587\u732e\u306b\u767b\u5834\u3057\u305d\u306e\u7406\u8ad6\u304c\u8ad6\u3058\u3089\u308c\u3066\u304a\u308a\u3001\u305d\u308c\u4ee5\u6765\u3001\u4e16\u754c\u4e2d\u306e\u4eba\u3005\u304c\u30e9\u30dc\u3067\u306e\u5b9f\u7528\u5316\u3092\u8a66\u307f\u3066\u3044\u307e\u3059\u304c\u3001\u305d\u306e\u666e\u53ca\u306f\u8db3\u8e0f\u307f\u72b6\u614b\u3067\u3057\u305f\u3002\u5206\u96e2\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u30e9\u30dc\u306e\u52b9\u7387\u3092\u5927\u5e45\u306b\u6539\u5584\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3066\u3001\u3055\u3089\u306b\u3001\u305d\u306e\u5229\u70b9\u306b\u3064\u3044\u3066\u3082\u5e83\u304f\u8a8d\u77e5\u3055\u308c\u3066\u3044\u305f\u306b\u3082\u304b\u304b\u308f\u3089\u305a\uff3b1\uff0d15\uff3d\u3001\u306a\u305cLPGC-MS\u306f\u666e\u53ca\u3057\u306a\u304b\u3063\u305f\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u5b9f\u306f\u3001LGPC-MS\u666e\u53ca\u306e\u969c\u58c1\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6027\u80fd\u306b\u95a2\u3059\u308b\u554f\u984c\u3067\u306f\u306a\u304f\u3001\u3080\u3057\u308d\u3001\u88c5\u7f6e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306e\u96e3\u3057\u3055\u306b\u3042\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC\u306e\u5b9f\u7528\u5316\u306b\u306f\u3001\u6ce8\u5165\u53e3\u306e\u30d8\u30c3\u30c9\u5727\u3092\u9069\u3057\u305f\u5727\u529b\u306b\u4fdd\u3064\u4e00\u65b9\u3067\u3001\u30ab\u30e9\u30e0\u51fa\u53e3\u5074\u304b\u3089\u30ab\u30e9\u30e0\u5185\u306e\u30ac\u30b9\u3092\u52b9\u679c\u7684\u306b\u6392\u6c17\u3057\u3001GC\u30ab\u30e9\u30e0\u5168\u4f53\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u305d\u3057\u3066\u3001\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u304c\u666e\u53ca\u3057\u305f\u3053\u3068\u306b\u3088\u308a\u3001\u7a7a\u6c17\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u30dd\u30f3\u30d7\u3067\u6392\u51fa\u3059\u308bMS\u306e\u771f\u7a7a\u30dd\u30f3\u30d7\u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u5185\u5727\u529b\u3092\u4e0b\u3052\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001GC\u30ab\u30e9\u30e0\u5185\u3092\u52b9\u7387\u7684\u306b\u6392\u6c17\u3067\u304d\u308b\u306e\u306f\u3001\u6bd4\u8f03\u7684\u30ab\u30e9\u30e0\u9577\u304c\u77ed\u304f\u5185\u5f84\u306e\u5927\u304d\u306a\u30ab\u30e9\u30e0\u306e\u307f\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u306e\u3088\u3046\u306a\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u3092\uff2d\uff33\u306b\u63a5\u7d9a\u3059\u308b\u3068\u3001\u901a\u5e38\u3067\u306fGC\u6ce8\u5165\u53e3\u3092\u6700\u9069\u306a\u30d8\u30c3\u30c9\u5727\u306b\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3064\u307e\u308a\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u4fdd\u3064\u3053\u3068\u306f\u3067\u304d\u3066\u3082\u3001\u30d8\u30c3\u30c9\u5727\u3092\u9069\u6b63\u306a\u5727\u529b\u3067\u5b89\u5b9a\u3057\u305f\u72b6\u614b\u306b\u7dad\u6301\u3059\u308b\u3068\u3044\u3046\u70b9\u306b\u304a\u3044\u3066\u8ab2\u984c\u304c\u6b8b\u3063\u3066\u3044\u305f\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u304b\u3057\u3053\u306e\u8ab2\u984c\u306f2000\u5e74\u4ee3\u521d\u982d\u306b\u89e3\u6c7a\u3055\u308c\u307e\u3059\u3002\u5206\u6790\u30ab\u30e9\u30e0\u306e\u30d5\u30ed\u30f3\u30c8\u30a8\u30f3\u30c9\u306b\u300c\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u300d\u3092\u63a5\u7d9a\u3059\u308b\u3053\u3068\u3067\u3001GC\u6ce8\u5165\u53e3\u306e\u30d8\u30c3\u30c9\u5727\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u3001MS\u306e\u771f\u7a7a\u30b7\u30b9\u30c6\u30e0\u306b\u3088\u3063\u3066\u5206\u6790\u30ab\u30e9\u30e0\u5185\u306e\u5727\u529b\u3092\u52b9\u679c\u7684\u306b\u4e0b\u3052\u308b\u3068\u3044\u3046\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u767b\u5834\u3057\u305f\u306e\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u975e\u5e38\u306b\u7d30\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30c1\u30e5\u30fc\u30d6\u306e\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u3001\u592a\u3044\u5206\u6790\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u304c\u3046\u307e\u304f\u3044\u304b\u306a\u3044\u3001\u3068\u3044\u3046\u65b0\u305f\u306a\u554f\u984c\u306b\u76f4\u9762\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7570\u306a\u308b\u5185\u5f84\u3092\u6301\u3064\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u3053\u3068\u306f\u3001\u975e\u5e38\u306b\u96e3\u3057\u3044\u4f5c\u696d\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u30010.18 mm \u5185\u5f84\u306e\u30ab\u30e9\u30e0\u30920.53 mm \u5185\u5f84\u306e\u30ab\u30e9\u30e0\u3068\u63a5\u7d9a\u3059\u308b\u3053\u3068\u3092\u60f3\u50cf\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002GC\u306e\u5c02\u9580\u5bb6\u3067\u3055\u3048\u3001\u7570\u5f84\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30c1\u30e5\u30fc\u30d6\u306e\u63a5\u7d9a\u4f5c\u696d\u306f\u907f\u3051\u305f\u3044\u3068\u8003\u3048\u308b\u3067\u3057\u3087\u3046\u3057\u3001\u30ea\u30fc\u30af\u306e\u30ea\u30b9\u30af\u304c\u3042\u308b\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u306f\u6975\u529b\u907f\u3051\u305f\u3044\u3068\u3053\u308d\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u3053\u3046\u3057\u305f\u63a5\u7d9a\u306b\u306f\u3001\u4fe1\u983c\u6027\u304c\u9ad8\u304f\u5805\u7262\u306a\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u3082\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u901a\u5e38\u306eGC\u30aa\u30fc\u30d6\u30f3\u5185\u3067\u3082\u30b3\u30cd\u30af\u30bf\u306f\u53b3\u3057\u3044\u6761\u4ef6\u306b\u8010\u3048\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001LPGC\u3067\u306f\u5206\u6790\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u306b\u4f34\u3046\u6607\u6e29\u30b5\u30a4\u30af\u30eb\u306e\u9ad8\u901f\u5316\u306b\u3088\u308a\u305d\u306e\u8ca0\u8377\u306f\u3055\u3089\u306b\u5897\u3057\u307e\u3059\u3002\u3082\u3057\u30b3\u30cd\u30af\u30bf\u306b\u554f\u984c\u304c\u751f\u3058\u308c\u3070\u3001\u30ab\u30e9\u30e0\u306e\u4ea4\u63db\u3084\u30b5\u30f3\u30d7\u30eb\u306e\u518d\u5206\u6790\u304c\u5fc5\u8981\u3068\u306a\u308a\u3001\u6642\u9593\u3068\u30b3\u30b9\u30c8\u304c\u7121\u99c4\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u304c\u63d0\u4f9b\u3059\u308b\u5206\u6790\u306e\u9ad8\u901f\u5316\u3084\u30d8\u30ea\u30a6\u30e0\u6d88\u8cbb\u91cf\u306e\u524a\u6e1b\u52b9\u679c\u306f\u3001\u6570\u3005\u306e\u7814\u7a76\u3067\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u308b\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u3001\u3053\u308c\u3089\u306e\u63a5\u7d9a\u4e0a\u306e\u8ab2\u984c\u304c\u305d\u306e\u5e83\u7bc4\u306a\u666e\u53ca\u3092\u59a8\u3052\u3066\u304d\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3001Restek\u306f\u3053\u308c\u3089\u306e\u8ab2\u984c\u306b\u5bfe\u51e6\u3059\u308b\u305f\u3081\u306b\u3001Restek\u5de5\u5834\u3067\u3042\u3089\u304b\u3058\u3081\u63a5\u7d9a\u3057\u3066\u4fe1\u983c\u6027\u3092\u78ba\u4fdd\u3057\u305f\u30ea\u30fc\u30af\u30d5\u30ea\u30fc\uff08\u30ea\u30fc\u30af\u306e\u306a\u3044\uff09Low-Pressure GC\uff08LPGC\uff09\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ad\u30c3\u30c8\u306f\u3001LPGC-MS\u306e\u5229\u70b9\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3057\u3001\u65e5\u3005\u306e\u5206\u6790\u4f5c\u696d\u3092\u3088\u308a\u52b9\u7387\u7684\u304b\u3064\u5b89\u5fc3\u3057\u3066\u884c\u3046\u305f\u3081\u306e\u6700\u826f\u306e\u89e3\u6c7a\u7b56\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b7\u30f3\u30d7\u30eb\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3 &#8211; LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001\u3053\u308c\u307e\u3067LPGC-MS\u306e\u666e\u53ca\u3092\u59a8\u3052\u3066\u304d\u305f\u8ab2\u984c\u3092\u514b\u670d\u3059\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306bLPGC-MS\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u304c\u3067\u304d\u308b\u306e\u3067\u3001\u591a\u304f\u306e\u30e9\u30dc\u3067LPGC-MS\u304c\u3082\u305f\u3089\u3059\u751f\u7523\u6027\u5411\u4e0a\u3068\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d88\u8cbb\u524a\u6e1b\u306e\u5229\u70b9\u3092\u6d3b\u7528\u3067\u304d\u307e\u3059\u3002LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001\u5fc5\u8981\u306a\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u304cRestek\u5de5\u5834\u3067\u30bc\u30ed\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3068\u306a\u308b\u3088\u3046\u63a5\u7d9a\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u30e6\u30fc\u30b6\u30fc\u81ea\u3089\u96e3\u3057\u3044\u63a5\u7d9a\u4f5c\u696d\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u305b\u3093\uff08<strong>Figure 3<\/strong>\u53c2\u7167\uff09\u3002Restek\u306eLPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u3001LPGC-MS\u306e\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u304c\u30ab\u30e9\u30e0\u306e\u4ea4\u63db\u3068\u540c\u3058\u304f\u3089\u3044\u30b7\u30f3\u30d7\u30eb\u3067\u3001\u8ab0\u306b\u3068\u3063\u3066\u3082\u7c21\u5358\u306a\u4f5c\u696d\u3068\u306a\u308b\u3088\u3046\u8a2d\u8a08\u3055\u308c\u3066\u304a\u308a\u3001\u30ea\u30fc\u30af\u306e\u306a\u3044\u6027\u80fd\u3092\u4fdd\u8a3c\u3059\u308b\u305f\u3081\u306b\u4e00\u3064\u4e00\u3064\u304c\u30c6\u30b9\u30c8\u3055\u308c\u3066\u51fa\u8377\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3<\/strong>: Low-Pressure GC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u69cb\u6210<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"783\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03-1024x783.jpg\" alt=\"\" class=\"wp-image-11739\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03-1024x783.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03-300x229.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03-768x587.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03-1536x1175.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-3-T-figure-article-GNAR3505B-03.jpg 2042w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u6ce8\u5165\u53e3\u5074\u306e\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306b\u306f\u3001\u9577\u30555 m\u3001\u5185\u5f840.18 mm\u307e\u305f\u306f0.15 mm\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3057\u3066\u304a\u308a\u3001\u3053\u306e\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30c1\u30e5\u30fc\u30d6\u3092GC\u6ce8\u5165\u53e3\u306b\u53d6\u308a\u4ed8\u3051\u308b\u3053\u3068\u3067\u3001\u30d8\u30c3\u30c9\u5727\u3092\u5b89\u5b9a\u7684\u306b\u7dad\u6301\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u6570\u767e\u56de\u306b\u308f\u305f\u308b\u6607\u6e29\u5206\u6790\u3067\u3082\u30ea\u30fc\u30af\u3057\u306a\u3044\u3088\u3046\u3001\u4e0d\u6d3b\u6027\u30fb\u30bc\u30ed\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30fb\u4f4e\u71b1\u5bb9\u91cf\u306eSilTite\u30ab\u30e9\u30e0\u30b3\u30cd\u30af\u30bf\u3092\u7528\u3044\u3066\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3057\u3066\u3044\u307e\u3059\u3002LPGC-MS\u306e\u6210\u529f\u306b\u4e0d\u53ef\u6b20\u3067\u3042\u308b\u5b89\u5b9a\u3057\u305f\u30ea\u30fc\u30af\u306e\u306a\u3044\u63a5\u7d9a\u3092\u78ba\u7acb\u3059\u308b\u305f\u3081\u306b\u3001\u3053\u306e\u63a5\u7d9a\u306fRestek\u5de5\u5834\u306b\u304a\u3044\u3066\u88fd\u9020\u5de5\u7a0b\u306e\u4e00\u90e8\u3068\u3057\u3066\u884c\u308f\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306eLPGC\u5206\u6790\u30ab\u30e9\u30e0\u306f\u3001MS\u306e\u771f\u7a7a\u30b7\u30b9\u30c6\u30e0\u3067\u52b9\u679c\u7684\u306b\u30ab\u30e9\u30e0\u5727\u3092\u4f4e\u5727\uff08\u771f\u7a7a\uff09\u306b\u7dad\u6301\u3067\u304d\u308b\u3088\u3046\u306a\u30b5\u30a4\u30ba\u304c\u9078\u629e\u3055\u308c\u3066\u304a\u308a\u3001\u5f93\u6765\u306e30 m \u00d7 0.25 mm \u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001\u3088\u308a\u77ed\u6642\u9593\u3067\u52b9\u7387\u7684\u306a\u5206\u6790\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u3001\u30e6\u30cb\u30fc\u30af\u306a\u56fa\u5b9a\u76f8\u3068\u30b5\u30a4\u30ba\u3092\u63a1\u7528\u3057\u3066\u304a\u308a\u3001\u975e\u5e38\u306b\u6c4e\u7528\u6027\u304c\u9ad8\u3044\u306e\u304c\u7279\u5fb4\u3067\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u6027\u80fd\u3092\u6700\u5927\u9650\u5f15\u304d\u51fa\u3059\u305f\u3081\u306b\u306f\u3001MS\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3078\u306e\u53d6\u308a\u4ed8\u3051\u306e\u969b\u306b\u300160:40\u306e\u3079\u30b9\u30da\u30eb\/\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u88fd\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3082\u5c0f\u3055\u3044\u3067\u3059\u304c\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002\u307e\u305f\u3001\u30ca\u30c3\u30c8\u3092\u7de0\u3081\u3059\u304e\u3066\u30c1\u30e5\u30fc\u30d6\u3092\u6f70\u3055\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u3053\u3068\u3082\u30dd\u30a4\u30f3\u30c8\u3067\u3059\uff08<strong>Figure 4<\/strong>\uff09\u3002\u307e\u305f\u30010.53 mm \u5185\u5f84\u306eLPGC\u30ad\u30c3\u30c8\u306b\u306f0.8 mm\u306e\u30d5\u30a7\u30e9\u30eb\u3092\u30010.32 mm \u5185\u5f84\u306e\u30ad\u30c3\u30c8\u306b\u306f0.5 mm\u306e\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4<\/strong>: \u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u30d9\u30b9\u30c8\u306a\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u305f\u3081\u306b\u300160:40\u306eVespel\/\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u88fd\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3057\u3001MS\u30ca\u30c3\u30c8\u306f\u7de0\u3081\u3059\u304e\u306a\u3044\u3088\u3046\u6ce8\u610f\uff1a0.53 mm \u5185\u5f84\u306e\u30ad\u30c3\u30c8\u306b\u306f0.8 mm\u30010.32 mm \u5185\u5f84\u306e\u30ad\u30c3\u30c8\u306b\u306f0.5 mm\u306e\u30d5\u30a7\u30e9\u30eb\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"746\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-1024x746.jpg\" alt=\"\" class=\"wp-image-11745\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-1024x746.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-300x219.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-768x560.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-1536x1119.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/39-4-T-figure-article-GNAR3505B-04-2048x1492.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u306e\u5229\u70b9\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3059\u308b\u306b\u306f\u3001300\u2103\u4ee5\u4e0a\u306e\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3067\u308230\uff5e40\u2103\/\u5206\u306e\u9ad8\u3044\u6607\u6e29\u901f\u5ea6\u304c\u53ef\u80fd\u306aGC\u304c\u5fc5\u8981\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u7c73\u56fd\u3067\u4e00\u822c\u7684\u306b\u666e\u53ca\u3057\u3066\u3044\u308b120V\u306eGC\u30aa\u30fc\u30d6\u30f3\u3067\u306f\u3001\u3053\u306e\u6607\u6e29\u901f\u5ea6\u3092\u9054\u6210\u3067\u304d\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u3001LPGC-MS\u306e\u9ad8\u901f\u5316\u306e\u5229\u70b9\u3092\u6700\u5927\u5316\u304c\u96e3\u3057\u3044\u30b1\u30fc\u30b9\u3082\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002200V\u4ee5\u4e0a\u306e\u96fb\u6e90\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u88c5\u7f6e\u3067\u3042\u308c\u3070\u53ef\u80fd\u3067\u3059\u304c\u3001120V\u306e\u30aa\u30fc\u30d6\u30f3\u3067\u306f\u3001Restek\u306eGC Accelerator\u30aa\u30fc\u30d6\u30f3\u30a4\u30f3\u30b5\u30fc\u30c8\u30ad\u30c3\u30c8\uff08cat.# 23849\uff09\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u6607\u6e29\u6027\u80fd\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u30a4\u30f3\u30b5\u30fc\u30c8\u306f\u3001\u975e\u5e38\u306b\u30b7\u30f3\u30d7\u30eb\u3067\u3059\u304c\u52b9\u679c\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u5bb9\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u3067\u3001120V\u306e\u88c5\u7f6e\u3067\u3082\u8fc5\u901f\u306a\u6607\u6e29\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u3082\u3061\u308d\u3093\u3001\u6607\u6e29\u901f\u5ea6\u3092\u4e0a\u3052\u306a\u304f\u3066\u3082LPGC-MS\u306f\u4f7f\u7528\u3067\u304d\u307e\u3059\u306e\u3067\u5fc5\u9808\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u3067\u8fc5\u901f\u306b\u6607\u6e29\u3067\u304d\u305f\u65b9\u304c\u3001\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u52b9\u679c\u306f\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LPGC\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u30dd\u30a4\u30f3\u30c8\u3068\u30b3\u30c4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u4e00\u822c\u7684\u306a\u30ad\u30e3\u30d4\u30e9\u30eaGC\u30ab\u30e9\u30e0\u306e\u4ea4\u63db\u3092\u3059\u308b\u306e\u3068\u540c\u3058\u3088\u3046\u306a\u4f5c\u696d\u3067\u7c21\u5358\u306b\u30b7\u30b9\u30c6\u30e0\u3092\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3067\u304d\u308b\u306e\u3067\u3001\u3059\u3050\u306bLPGC-MS\u306b\u9069\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3084\u79fb\u7ba1\u304c\u884c\u3048\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u52b9\u7387\u3088\u304f\u4f5c\u696d\u304c\u3067\u304d\u308b\u3088\u3046\u30dd\u30a4\u30f3\u30c8\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u6295\u8cc7\u306f\u5f93\u6765\u306e\u30e1\u30bd\u30c3\u30c9\u3088\u308a\u3082\u5206\u6790\u304c\u9ad8\u901f\u5316\u3055\u308c\u308b\u3053\u3068\u3067\u5341\u5206\u306b\u56de\u53ce\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u30fb\u79fb\u7ba1\u3067\u306f\u3001\u307e\u305a\u6700\u521d\u306bGC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u8a2d\u5b9a\u3059\u308b\u3068\u3053\u308d\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u3002\u8907\u6570\u306e\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u3092\u8a2d\u5b9a\u3067\u304d\u308b\u5834\u5408\u3067\u3082\u3001\u3054\u4f7f\u7528\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5b9a\u7fa9\u3059\u308b\u5834\u5408\u3001\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u9577\u3055\u3068\u5185\u5f84\u306e\u307f\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u5f93\u6765\u306eGC-MS\u30ab\u30e9\u30e0\u3067\u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u3092LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3078\u30e1\u30bd\u30c3\u30c9\u79fb\u7ba1\u3059\u308b\u969b\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305a\u3001\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u59cb\u6e29\u5ea6\u3068\u7d42\u4e86\u6e29\u5ea6\u3092\u4f7f\u7528\u3057\u3001\u30aa\u30fc\u30d6\u30f3\u306e\u6607\u6e29\u901f\u5ea6\u30922~4\u500d\u306b\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3054\u4f7f\u7528\u306eGC\u304c\u5bfe\u5fdc\u3067\u304d\u308b\u6607\u6e29\u901f\u5ea6\u306e\u7bc4\u56f2\u5185\u3067\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u6b21\u306b\u6d41\u91cf\u8abf\u6574\u3067\u3059\u304c\u3001LPGC-MS\u306b\u306f\u304a\u304a\u3088\u305d\u306e\u63a8\u5968\u6d41\u91cf\u304c\u3042\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u5408\u308f\u305b\u3066\u305d\u306e\u6d41\u91cf\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u4f5c\u6210\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306b\u5408\u308f\u305b\u3066\u3001\u540c\u3058\u6d41\u91cf\u6761\u4ef6\u3067MS\u3092\u518d\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u3057\u611f\u5ea6\u8abf\u6574\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u3057\u304b\u3057\u3001\u6d41\u91cf\u304c\u9ad8\u3059\u304e\u308b\u3068\u8cea\u91cf\u5206\u6790\u8a08\u306e\u771f\u7a7a\u5ea6\u3078\u306e\u5f71\u97ff\u304c\u51fa\u3066\u3001\u611f\u5ea6\u304c\u4f4e\u4e0b\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u3067\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC-MS\u3067\u306f\u5206\u96e2\u5ea6\u4f4e\u4e0b\u304c\u89b3\u5bdf\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u3053\u306e\u70b9\u306f\u8cea\u91cf\u5206\u6790\u8a08\u3092\u7528\u3044\u308c\u3070MS\u5206\u96e2\u3067\u5bfe\u7b56\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5f93\u6765\u306eGC-MS\u30e1\u30bd\u30c3\u30c9\u3067\u3001\u5171\u901a\u3059\u308b\u7279\u5b9a\u306e\u30a4\u30aa\u30f3\u3092\u6301\u3064\u5316\u5408\u7269\u540c\u58eb\u304c\u8fd1\u63a5\u3057\u3066\u6eb6\u51fa\u3059\u308b\u5834\u5408\u306fLPGC-MS\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u5171\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u304cMS\u5206\u96e2\u3067\u304d\u306a\u3044\u5834\u5408\u3001LPGC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u969b\u306b\u3001\u5206\u96e2\u6761\u4ef6\u306e\u8abf\u6574\u304c\u5fc5\u8981\u306b\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u7279\u306b\u8cea\u91cf\u30b9\u30da\u30af\u30c8\u30eb\u304c\u975e\u5e38\u306b\u985e\u4f3c\u3057\u3066\u3044\u308b\u5316\u5408\u7269\u540c\u58eb\u306e\u5834\u5408\u3001\u3053\u306e\u554f\u984c\u304c\u9855\u8457\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30aa\u30f3\u30e9\u30a4\u30f3\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30b5\u30a4\u30ba\u306e\u7570\u306a\u308b\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u65b0\u3057\u3044\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3092\u8a08\u7b97\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001Low-Pressure GC\u3067\u306f\u3053\u306e\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u306f\u591a\u5c11\u306e\u6642\u9593\u7684\u6295\u8cc7\u304c\u5fc5\u8981\u3067\u3059\u304c\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5927\u5e45\u306a\u5411\u4e0a\u306b\u3088\u308a\u3001\u305d\u306e\u6295\u8cc7\u306f\u3059\u3050\u306b\u56de\u53ce\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001Restek\u3067\u306f\u5f93\u6765\u306eGC-MS\u304b\u3089LPGC-MS\u3078\u306e\u30e1\u30bd\u30c3\u30c9\u79fb\u7ba1\u306b\u3064\u3044\u3066\u3001Step-by-Step\u306e\u30ac\u30a4\u30c0\u30f3\u30b9\u3084\u30b5\u30dd\u30fc\u30c8\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u5fc5\u8981\u306a\u6642\u9593\u3092\u6700\u5c0f\u5316\u3059\u308b\u305f\u3081\u306b\u3001\u305d\u3061\u3089\u3082\u662f\u975e\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Restek\u306eLPGC-MS\u30ad\u30c3\u30c8\u3060\u304b\u3089\u3053\u305d\u306e\u4fe1\u983c\u3068\u5b89\u5fc3<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u304f\u3055\u3093\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u65e5\u5e38\u7684\u306b\u51e6\u7406\u3057\u3066\u3044\u308b\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30e9\u30dc\u3067\u306f\u3001\u3044\u304b\u306a\u308b\u65b0\u3057\u3044\u624b\u6cd5\u306e\u5c0e\u5165\u3082\u30ea\u30b9\u30af\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u305d\u306e\u30ea\u30b9\u30af\u3092\u56de\u907f\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5805\u7262\u3067\u5b89\u5b9a\u6027\u306e\u9ad8\u3044\u30e1\u30bd\u30c3\u30c9\u3092\u9078\u3076\u3053\u3068\u3067\u3059\u3002\u5341\u5206\u306a\u691c\u8a0e\u3092\u7d4c\u3066LPGC-MS\u30e1\u30bd\u30c3\u30c9\u304c\u958b\u767a\u3055\u308c\u3001Restek\u306e\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u304c\u30a4\u30f3\u30b9\u30c8\u30fc\u30eb\u3055\u308c\u308c\u3070\u3001LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\uff08<strong>Figure 5<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5: <\/strong>LPGC-MS\u3067\u30db\u30a6\u30ec\u30f3\u30bd\u30a6\u62bd\u51fa\u7269\u3092500\u56de\u6ce8\u5165\u3057\u3066\u3082\u3001\u3053\u308c\u3089\u306e\u7570\u6027\u4f53\u306e\u5206\u96e2\u5ea6\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u5206\u89e3\u80fd\u3001\u4fdd\u6301\u6642\u9593\u306b\u5909\u5316\u306f\u898b\u308c\u308c\u306a\u304b\u3063\u305f<br>\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\uff08\u82f1\u6587\uff09\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0574.png\" alt=\"Permethrins Resolution Stability on Low-Pressure GC Column Kit (500 Injections, Spinach Matrix)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0574<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31152<\/li><li>11800<\/li><li>23447<\/li><li>25849<\/li><li>26219<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>LPGC<\/li><li>pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0574.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f93\u6765\u3001LPGC-MS\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3067\u6700\u3082\u8106\u5f31\u306a\u90e8\u5206\u306e1\u3064\u306f\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3068\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u90e8\u5206\u3067\u3059\u3002GC\u30aa\u30fc\u30d6\u30f3\u5185\u306e\u74b0\u5883\u306f\u30ab\u30e9\u30e0\u63a5\u7d9a\u306b\u3068\u3063\u3066\u975e\u5e38\u306b\u53b3\u3057\u304f\u3001\u6025\u6fc0\u306a\u6607\u6e29\u3084\u964d\u6e29\u304c\u7e70\u308a\u8fd4\u3055\u308c\u308b\u3053\u3068\u3067\u3001\u7570\u306a\u308b\u6750\u8cea\uff08\u4f8b\u3048\u3070\u30ab\u30e9\u30e0\u3068\u30b3\u30cd\u30af\u30bf\uff09\u304c\u4e0d\u5747\u4e00\u306b\u81a8\u5f35\u30fb\u53ce\u7e2e\u3092\u7e70\u308a\u8fd4\u3059\u7d50\u679c\u3001\u63a5\u7d9a\u90e8\u4f4d\u304b\u3089\u306e\u30ea\u30fc\u30af\u30ea\u30b9\u30af\u304c\u9ad8\u307e\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30aa\u30fc\u30d6\u30f3\u51b7\u5374\u6642\u306b\u30aa\u30fc\u30d6\u30f3\u30d5\u30a1\u30f3\u304b\u3089\u306e\u98a8\u304c\u30ab\u30e9\u30e0\u63a5\u7d9a\u306b\u5927\u304d\u306a\u30b9\u30c8\u30ec\u30b9\u3092\u4e0e\u3048\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u63a5\u7d9a\u90e8\u4f4d\u3067\u306e\u30ea\u30fc\u30af\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30d0\u30c3\u30c1\u5168\u4f53\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u3001\u518d\u5206\u6790\u3084\u4e88\u671f\u305b\u306c\u30ab\u30e9\u30e0\u4ea4\u63db\u3068\u3044\u3063\u305f\u30c8\u30e9\u30d6\u30eb\u767a\u751f\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u7279\u306bLPGC\u6761\u4ef6\u4e0b\u3067\u306f\u3001\u30ab\u30e9\u30e0\u63a5\u7d9a\u90e8\u4f4d\u306f\u3001MS\u306e\u771f\u7a7a\u30dd\u30f3\u30d7\u304b\u3089\u306e\u5438\u5f15\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u305f\u3081\u3001\u63a5\u7d9a\u306e\u5b89\u5b9a\u6027\u304c\u6975\u3081\u3066\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3059\u308b\u305f\u3081\u306b\u3001Restek\u306f\u4e88\u3081\u7d44\u307f\u7acb\u3066\u3089\u308c\u305f\u30ad\u30c3\u30c8\u3068\u3057\u3066LPGC\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u79c1\u305f\u3061\u306f\u9577\u5e74\u306b\u308f\u305f\u3063\u3066\u3055\u307e\u3056\u307e\u306a\u30ab\u30e9\u30e0\u63a5\u7d9a\u6280\u8853\u3092\u5fb9\u5e95\u7684\u306b\u7814\u7a76\u3057\u3066\u304d\u307e\u3057\u305f\u3002 Low-Pressure GC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u4f4e\u71b1\u5bb9\u91cf\u30fb\u30bc\u30ed\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u30fb\u4e0d\u6d3b\u6027\u30b3\u30cd\u30af\u30bf\u306f\u5805\u7262\u3067\u3001\u9577\u6642\u9593\u4f7f\u7528\u3057\u3066\u3082\u6f0f\u308c\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u7279\u5225\u306b\u8a13\u7df4\u3055\u308c\u305f\u88fd\u9020\u62c5\u5f53\u8005\u304c\u3001\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u305f\u30c4\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3066\u63a5\u7d9a\u3092\u78ba\u5b9f\u306b\u884c\u3063\u305f\u306e\u3061\u3001\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u306f\u3001\u88fd\u9020\u6642\u306e\u54c1\u8cea\u7ba1\u7406\u8a55\u4fa1\u3068\u3057\u3066\u30ea\u30fc\u30af\u8a66\u9a13\u3092\u53d7\u3051\u3001\u5408\u683c\u3057\u305f\u3082\u306e\u3060\u3051\u304c\u51fa\u8377\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 5<\/strong>\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001Restek\u306eLPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3067\u306f\u3001500\u56de\u306e\u30ab\u30e9\u30e0\u8010\u4e45\u8a66\u9a13\u3092\u901a\u3057\u3066\u9855\u8457\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u3084\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u5909\u52d5\u304c\u306a\u3044\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u6ce8\u5165\u3068\u540c\u6570\u7e70\u308a\u8fd4\u3055\u308c\u308b\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u7d4c\u3066\u3082\u30ea\u30fc\u30af\u767a\u751f\u304c\u306a\u304b\u3063\u305f\u3068\u3044\u3046\u3053\u3068\u3092\u3053\u306e\u7d50\u679c\u306f\u793a\u5506\u3057\u3066\u3044\u308b\u3068\u8a00\u3048\u307e\u3059\u3002\u307e\u305f\u3001<strong>Table II<\/strong>\u306f\u3001LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u30a4\u30f3\u30b9\u30c8\u30fc\u30eb\u3057\u305fGC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u8a66\u9a13\u306e\u7d50\u679c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u7d50\u679c\u304b\u3089\u3082\u3001500\u56de\u306e\u8a66\u9a13\u3092\u901a\u3058\u3066\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308b\u30ea\u30fc\u30af\u304c\u6291\u3048\u3089\u308c\u3001\u5b89\u5b9a\u7684\u306a\u5206\u6790\u304c\u7dad\u6301\u3055\u308c\u3066\u3044\u305f\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II<\/strong>&nbsp;: \u6ce8\u5165500 \u56de\u306e\u8010\u4e45\u8a66\u9a13\u306b\u304a\u3051\u308b\u8cea\u91cf\u5206\u6790\u8a08\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u7d50\u679c<br>\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u6210\u5206\u306e\u30ec\u30b9\u30dd\u30f3\u30b9\u306f\u8a66\u9a13\u5168\u4f53\u3092\u901a\u3057\u3066\u4e00\u8cab\u3057\u3066\u304a\u308a\u3001\u30ea\u30fc\u30af\u306e\u5146\u5019\u3092\u793a\u3059\u30a4\u30aa\u30f3\uff08\u4f8b\u3048\u3070\u3001\u6c34\u3001\u7a92\u7d20\u3001\u9178\u7d20\u306em\/z 18\u300128\u300132\uff09\u3082\u4e00\u8cab\u3057\u3066\u4f4e\u3044\u30ec\u30d9\u30eb\u306b\u7dad\u6301\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001500\u56de\u306e\u8010\u4e45\u8a66\u9a13\u306b\u304a\u3044\u3066\u30ea\u30fc\u30af\u306e\u767a\u751f\u304c\u306a\u304b\u3063\u305f\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>70-320\u00b0C\u306e\u30aa\u30fc\u30d6\u30f3\u30b5\u30a4\u30af\u30eb\u6570<\/strong><\/td><td><strong>\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u6210\u5206\u306b\u5bfe\u3059\u308b\u30ea\u30fc\u30af\u7387<\/strong><\/td><td><strong>\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u6210\u5206\uff08m\/z 69\uff09\u5f37\u5ea6\uff0810x\uff09<\/strong><\/td><td><strong>\u30c1\u30e5\u30fc\u30cb\u30f3\u30b0\u6210\u5206\uff08m\/z 69\uff09\u30b7\u30b0\u30ca\u30eb\u306e\u534a\u5024\u5168\u5e45\uff08m\/z\uff09<\/strong><\/td><\/tr><tr><td>0<\/td><td>5.03 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.70<\/td><\/tr><tr><td>100<\/td><td>4.69 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.71<\/td><\/tr><tr><td>200<\/td><td>4.08 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.71<\/td><\/tr><tr><td>300<\/td><td>3.85 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.71<\/td><\/tr><tr><td>400<\/td><td>3.40 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.71<\/td><\/tr><tr><td>500<\/td><td>4.59 % &#8211; Pass<\/td><td>10<sup>7<\/sup><\/td><td>0.72<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">LPGC\u30ab\u30e9\u30e0\u306e\u30e1\u30f3\u30c6\u30f3\u30ca\u30f3\u30b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306f\u9577\u5bff\u547d\u3067\u3042\u308b\u3053\u3068\u304c\u671f\u5f85\u3055\u308c\u307e\u3059\u304c\u3001\u5206\u6790\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u6570\u304a\u3088\u3073\u30bf\u30a4\u30d7\u3001\u306a\u3089\u3073\u306b\u5b9f\u65bd\u3055\u308c\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u7a0b\u5ea6\u306b\u5fdc\u3058\u3066\u5b9a\u671f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306f\u5fc5\u8981\u3067\u3059\u3002\u6ce8\u5165\u53e3\u6d88\u8017\u90e8\u54c1\uff08\u30e9\u30a4\u30ca\u30fc\u3084\u30b7\u30fc\u30eb\u306a\u3069\uff09\u306e\u4ea4\u63db\u3067\u30b7\u30b9\u30c6\u30e0\u6027\u80fd\u304c\u56de\u5fa9\u3057\u306a\u3044\u5834\u5408\u3001\u5f93\u6765\u306eGC-MS\u30ab\u30e9\u30e0\u3068\u540c\u3058\u3088\u3046\u306b\u3001\u30ab\u30e9\u30e0\u306e\u4e00\u90e8\u3092\u30ab\u30c3\u30c8\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5f93\u6765\u306eGC-MS\u30ab\u30e9\u30e0\u3068\u306f\u7570\u306a\u308a\u3001LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306e\u30ab\u30c3\u30c8\u306f\u5206\u6790\u30ab\u30e9\u30e0\u3067\u306f\u306a\u304f\u3001\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u6b8b\u7559\u7269\u304c\u84c4\u7a4d\u3055\u308c\u305f\u53ef\u80fd\u6027\u306e\u3042\u308b\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3067\u884c\u3044\u307e\u3059\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u30a4\u30f3\u30ec\u30c3\u30c8\u5074\u304b\u308910~30cm\u3092\u30ab\u30c3\u30c8\u3059\u308b\u3068\u307b\u3068\u3093\u3069\u306e\u5834\u5408\u3067\u6027\u80fd\u306f\u56de\u5fa9\u3057\u307e\u3059\u304c\u3001\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u306e\u9577\u3055\u306f5\u30e1\u30fc\u30c8\u30eb\u3057\u304b\u306a\u3044\u305f\u3081\u3001\u30ab\u30c3\u30c8\u306f\u3067\u304d\u308b\u3060\u3051\u77ed\u304f\u884c\u3044\u3001\u30ab\u30e9\u30e0\u30ab\u30c3\u30c8\u306f\u5408\u8a083\u30e1\u30fc\u30c8\u30eb\u672a\u6e80\u3068\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3092\u5207\u308a\u3059\u304e\u308b\u3068\u3001GC\u6ce8\u5165\u53e3\u306bMS\u771f\u7a7a\u30dd\u30f3\u30d7\u306e\u5438\u5f15\u306e\u5f71\u97ff\u304c\u51fa\u3066\u3001\u6ce8\u5165\u53e3\u306e\u30d8\u30c3\u30c9\u5727\u3092\u5b89\u5b9a\u7684\u306b\u9069\u6b63\u5727\u306b\u7dad\u6301\u3067\u304d\u306a\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ea\u30b9\u30c8\u30ea\u30af\u30bf\u30ab\u30e9\u30e0\u3092\u30ab\u30c3\u30c8\u3059\u308b\u3068\u4fdd\u6301\u6642\u9593\u304c\u5909\u5316\u3059\u308b\u305f\u3081\u3001\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5909\u66f4\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002GC\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u8a2d\u5b9a\u3067\u30ab\u30e9\u30e0\u9577\u3055\u3092\u8abf\u6574\u3057\u3066\u540c\u3058\u6d41\u91cf\u3067\u5206\u6790\u3092\u7d9a\u3051\u308b\u304b\u3001\u307e\u305f\u306f\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u4e0a\u306e\u30ab\u30e9\u30e0\u9577\u306f\u5909\u66f4\u305b\u305a\u6d41\u91cf\uff08\u7dda\u901f\u5ea6\uff09\u3092\u4e0b\u3052\u3066\u3001\u30ab\u30e9\u30e0\u30ab\u30c3\u30c8\u306b\u5bfe\u5fdc\u3059\u308b\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u5909\u66f4\u306b\u3088\u308a\u4fdd\u6301\u6642\u9593\u304c\u6b63\u3057\u304f\u8abf\u6574\u3055\u308c\u308c\u3070\u3001MS\u306e\u89e3\u6790\u30a6\u30a3\u30f3\u30c9\u30a6\u3092\u5909\u66f4\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u5ff5\u306e\u305f\u3081\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306e\u524d\u306b\u78ba\u8a8d\u3059\u308b\u3068\u826f\u3044\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4ea4\u63db\u3059\u308b\u969b\u306b\u306f\u3001\u30ad\u30c3\u30c8\u5168\u4f53\u306e\u4ea4\u63db\u3092\u304a\u9858\u3044\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30fc\u30af\u306e\u306a\u3044\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u305f\u3001Restek\u5de5\u5834\u3067\u63a5\u7d9a\u6e08\u307f\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3001LPGC-MS\u306b\u3088\u308b\u5206\u6790\u6642\u9593\u306e\u77ed\u7e2e\u3068\u30d8\u30ea\u30a6\u30e0\u6d88\u8cbb\u91cf\u306e\u524a\u6e1b\u306e\u6069\u6075\u3092\u53d7\u3051\u308b\u3001\u6700\u3082\u7c21\u5358\u3067\u3001\u8fc5\u901f\u304b\u3064\u6975\u3081\u3066\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u65b9\u6cd5\u3067\u3042\u308b\u305f\u3081\u3001\u30ad\u30c3\u30c8\u3092\u5206\u89e3\u3057\u3066\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u63a5\u7d9a\u3059\u308b\u3053\u3068\u306f\u63a8\u5968\u3057\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u3057\u3044LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u53d6\u308a\u4ed8\u3051\u308b\u3068\u3001\u76ee\u7684\u6210\u5206\u306e\u7d76\u5bfe\u4fdd\u6301\u6642\u9593\u304c\u5909\u52d5\uff08\u30b7\u30d5\u30c8\uff09\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u5316\u5408\u7269\u9593\u306e\u76f8\u5bfe\u7684\u306a\u5206\u96e2\u306f\u3001\u30ad\u30c3\u30c8\u9593\u3067\u4e00\u8cab\u6027\u3092\u4fdd\u3064\u306f\u305a\u3067\u3059\u304c\u3001\u00b110\u79d2\u3092\u8d85\u3048\u308b\u3088\u3046\u306a\u7d76\u5bfe\u4fdd\u6301\u6642\u9593\u306e\u30b7\u30d5\u30c8\u306b\u5bfe\u5fdc\u3059\u308b\u306b\u306f\u3001\u76ee\u7684\u6210\u5206\u306e\u4fdd\u6301\u6642\u9593\u30a6\u30a3\u30f3\u30c9\u30a6\u306e\u518d\u8a2d\u5b9a\u304c\u5fc5\u8981\u306b\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002MS\u30a4\u30aa\u30f3\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u30a6\u30a3\u30f3\u30c9\u30a6\u3092\u5e83\u3052\u305f\u30e1\u30bd\u30c3\u30c9\u3067\u6a19\u6e96\u7269\u8cea\u3092\u5206\u6790\u3059\u308c\u3070\u3001\u4fdd\u6301\u6642\u9593\u30a6\u30a3\u30f3\u30c9\u30a6\u3092\u7d20\u65e9\u304f\u518d\u8a2d\u5b9a\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u5fc5\u8981\u304c\u3042\u308c\u3070\u4fdd\u6301\u6642\u9593\u306b\u5408\u308f\u305b\u3066\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u8abf\u6574\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Low-Pressure GC-MS\u306e\u30b7\u30f3\u30d7\u30eb\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC-MS\u306e\u771f\u7a7a\u30b7\u30b9\u30c6\u30e0\u3092\u6d3b\u7528\u3057\u305fRestek\u306eLow-Pressure GC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u4ea4\u63db\u3068\u30e1\u30bd\u30c3\u30c9\u66f4\u65b0\u3060\u3051\u3067\u3001\u8ab0\u3067\u3082\u7c21\u5358\u306b\u88c5\u7f6e\u306e\u751f\u7523\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002LPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u3092\u4f7f\u3048\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u6539\u5584\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30d8\u30ea\u30a6\u30e0\u4f7f\u7528\u91cf\u3082\u5927\u5e45\u524a\u6e1b\u304c\u53ef\u80fd\u3067\u3059\u3002\u5927\u304d\u306a\u6295\u8cc7\u304c\u5fc5\u8981\u3068\u306a\u308b\u65b0\u88c5\u7f6e\u306e\u5c0e\u5165\u3060\u3051\u304c\u3001\u30e9\u30dc\u306e\u52b9\u7387\u5316\u3092\u53f6\u3048\u308b\u9078\u629e\u80a2\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002Restek\u306eLPGC\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8\u306a\u3089\u73fe\u5728\u306e\u30ea\u30bd\u30fc\u30b9\uff08\u65e2\u5b58\u88c5\u7f6e\uff09\u3092\u6700\u5927\u9650\u6d3b\u7528\u3057\u306a\u304c\u3089\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306e\u5927\u5207\u306a\u6642\u9593\u3092\u6709\u52b9\u6d3b\u7528\u3057\u3001\u30e9\u30dc\u306e\u30b3\u30b9\u30c8\u524a\u6e1b\u3092\u5b9f\u73fe\u3059\u308b\u9078\u629e\u80a2\u306b\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>B. Gruber, F. David, and P. Sandra,&nbsp;<em>Trends Anal. Chem.&nbsp;<\/em>124, 115475 (2020).<\/li>\n\n\n\n<li>S.J. Lehotay, J. de Zeeuw, Y. Sapozhnikova, N. Michlig, J. Rousova Hepner, J.D. Konschnik,&nbsp;<em>LCGC North Am.&nbsp;<\/em>38, 457\u2013466 (2020).<\/li>\n\n\n\n<li>S.J. Lehotay, N. Michlig, and A.R. Lightfield,&nbsp;<em>J. Agric. Food Chem.&nbsp;<\/em>68, 1468\u20131479 (2020).<\/li>\n\n\n\n<li>L. Han, S.J. Lehotay, and Y. Sapozhnikova,&nbsp;<em>J. Agric. Food Chem.&nbsp;<\/em>66, 4986\u20134996 (2018).<\/li>\n\n\n\n<li>S.J. Lehotay and Y. Chen,&nbsp;<em>Anal. Bioanal. Chem.&nbsp;<\/em>410, 5331\u20135351 (2018).<\/li>\n\n\n\n<li>S.J. Lehotay, L. Han, and Y. Sapozhnikova,&nbsp;<em>Anal. Bioanal. Chem.&nbsp;<\/em>410, 5465\u20135479 (2018).<\/li>\n\n\n\n<li>Y. Sapozhnikova,&nbsp;<em>J. Chromatogr. A&nbsp;<\/em>1572, 203\u2013211 (2018).<\/li>\n\n\n\n<li>J. Hinshaw,&nbsp;<em>LCGC North Am.&nbsp;<\/em>35, 810\u2013815 (2017).<\/li>\n\n\n\n<li>L. Han, Y. Sapozhnikova, and S.J. Lehotay,&nbsp;<em>Food Control&nbsp;<\/em>66, 270\u2013282 (2016).<\/li>\n\n\n\n<li>S.J. Lehotay, L. Han, and Y. Sapozhnikova,&nbsp;<em>Chromatographia&nbsp;<\/em>79, 1113\u20131130 (2016).<\/li>\n\n\n\n<li>J. de Zeeuw, S. Reese, J. Cochran, S. Grossman, T. Kane, and C. English,&nbsp;<em>J. Sep. Sci.&nbsp;<\/em>32, 1849\u20131857 (2009).<\/li>\n\n\n\n<li>K. Ma\u0161tovska and S.J. Lehotay,&nbsp;<em>J.Chromatogr. A&nbsp;<\/em>1000, 153\u2013180 (2003).<\/li>\n\n\n\n<li>M.S. Klee and L.M. Blumberg,&nbsp;<em>J. Chromatogr. Sci.&nbsp;<\/em>40, 234\u2013247 (2002).<\/li>\n\n\n\n<li>K. Ma\u0161tovska, S.J. Lehotay, and J. Haj\u0161lova,&nbsp;<em>J. Chromatogr. A&nbsp;<\/em>926, 291\u2013308 (2001).<\/li>\n\n\n\n<li>J. de Zeeuw, J. Peene, H.-G. Janssen, and X. Lou,&nbsp;<em>J. High Res. Chromatogr.&nbsp;<\/em>23, 677\u2013680 (2000).<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11804\">                                \u30ab\u30bf\u30ed\u30b0No. 11804                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rxi-624Sil MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8, 0.32 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11804\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11806\">                                \u30ab\u30bf\u30ed\u30b0No. 11806                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rxi-35Sil MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11806\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11805\">                                \u30ab\u30bf\u30ed\u30b0No. 11805                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rxi-17Sil MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11805\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11803\">                                \u30ab\u30bf\u30ed\u30b0No. 11803                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rxi-624Sil MS\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8, 0.53 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11803\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11800\">                                \u30ab\u30bf\u30ed\u30b0No. 11800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-5ms\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8, 0.53 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11800\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11802\">                                \u30ab\u30bf\u30ed\u30b0No. 11802                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-5ms\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8, 0.32 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11802\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11807\">                                \u30ab\u30bf\u30ed\u30b0No. 11807                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-200\u30ab\u30e9\u30e0\u30ad\u30c3\u30c8<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11807\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23849\">                                \u30ab\u30bf\u30ed\u30b0No. 23849                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC Accelerator Oven Insert Kit, for Agilent 5890, 6890, 7890, and 8890 GCs<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23849\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4f4e\u5727GC\uff08Low Pressure GC\u3001LPGC\uff09\u306f\u3001\u9ad8\u901f\u5206\u6790\u3068\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5b9f\u73fe\u3057\u3001\u30d8\u30ea\u30a6\u30e0\u6d88\u8cbb\u3092\u6700\u592781\uff05\u524a\u6e1b\u3057\u307e\u3059\u3002\u7c21\u5358\u306a\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3067\u3001\u52b9\u7387\u7684\u306a\u30d8\u30ea\u30a6\u30e0\u524a\u6e1b\u3068GC\u306e\u9ad8\u901f\u5316\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u9769\u65b0\u7684\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":7140,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[2275,2274],"post-badge":[],"resource-type":[],"product-library":[2564,2566,2552],"resource-technique":[2340,2344,2345],"ppma_author":[2814],"class_list":["post-45324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","industries-application-food-safety-ja","industries-application-food-beverage-ja","product-library-gc-columns-ja","product-library-inlet-supplies-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-low-pressure-gc-lpgc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2566,"label":"GC \u6ce8\u5165\u53e3\u95a2\u9023\u90e8\u54c1"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2344,"label":"\u4f4e\u5727\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc (LPGC)"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR3505-1024x550.jpg",1024,550,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45324"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45324\/revisions"}],"predecessor-version":[{"id":69163,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45324\/revisions\/69163"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7140"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45324"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45324"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45324"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45324"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45324"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45324"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}