{"id":45327,"date":"2022-09-19T00:00:00","date_gmt":"2022-09-19T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/pro-ezlc-chromatogram-modeler-help-japan\/"},"modified":"2026-08-10T04:31:33","modified_gmt":"2026-08-10T04:31:33","slug":"pro-ezlc-chromatogram-modeler-help-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3918-ja\/pro-ezlc-chromatogram-modeler-help-japan","title":{"rendered":"Pro <em>EZ<\/em>LC Chromatogram Modeler \u30d8\u30eb\u30d7"},"content":{"rendered":"\n<div style=\"height:10px\" aria-hidden=\"true\" id=\"top-of-page\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"background-color:#f5f7fa; border:1px solid #e0e4e8; border-radius:8px; padding:24px; margin-bottom:24px;\">\n  <p style=\"font-weight:bold; font-size:20px; margin-bottom:12px;\">\u76ee\u6b21<\/p>\n  <ul style=\"list-style:none; margin:0; padding:0; line-height:1.9; font-size:18px;\">\n    <li><a href=\"#mokuji1\" style=\"text-decoration:none; color:#1a5fb4; font-weight:bold;\">Pro <em>EZ<\/em>LC\u3068\u306f?<\/a><\/li>\n    <li>\n      <a href=\"#mokuji2\" style=\"text-decoration:none; color:#1a5fb4; font-weight:bold;\">Pro <em>EZ<\/em>LC\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9<\/a>\n      <ul style=\"list-style:none; margin:6px 0 10px 20px; padding:0; line-height:1.8;\">\n        <li><a href=\"#mokuji3\" style=\"text-decoration:none; color:#1a5fb4;\">\u5316\u5408\u7269(Compounds)\u30bf\u30d6<\/a><\/li>\n        <li><a href=\"#mokuji4\" style=\"text-decoration:none; color:#1a5fb4;\">\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc<\/a><\/li>\n        <li><a href=\"#mokuji5\" style=\"text-decoration:none; color:#1a5fb4;\">\u5206\u6790\u6761\u4ef6(Conditions)\u30bf\u30d6<\/a><\/li>\n        <li><a href=\"#mokuji6\" style=\"text-decoration:none; color:#1a5fb4;\">PFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306etR\u3068\u5727\u529b\u3078\u306e\u5f71\u97ff<\/a><\/li>\n        <li><a href=\"#mokuji7\" style=\"text-decoration:none; color:#1a5fb4;\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6(Gradient Program)<\/a><\/li>\n        <li><a href=\"#mokuji8\" style=\"text-decoration:none; color:#1a5fb4;\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316(Optimize Gradient Slope)<\/a><\/li>\n        <li><a href=\"#mokuji9\" style=\"text-decoration:none; color:#1a5fb4;\">\u5316\u5408\u7269\u306e\u69cb\u9020\u3068\u7269\u6027\u30d3\u30e5\u30fc<\/a><\/li>\n        <li><a href=\"#mokuji10\" style=\"text-decoration:none; color:#1a5fb4;\">My <em>EZ<\/em>LC\u30bf\u30d6<\/a><\/li>\n        <li><a href=\"#mokuji11\" style=\"text-decoration:none; color:#1a5fb4;\">\u30e2\u30c7\u30eb\u306e\u5370\u5237<\/a><\/li>\n      <\/ul>\n    <\/li>\n  <\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001Pro <em>EZ<\/em>LC Chromatogram Modeler\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u3068\u5165\u529b\u9805\u76ee\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\u4f7f\u7528\u65b9\u6cd5\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001\u6280\u8853\u8a18\u4e8b\u304a\u3088\u3073\u7d39\u4ecb\u52d5\u753b\u3082\u305c\u3072\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 id=\"mokuji1\" class=\"wp-block-heading\">Pro <em>EZ<\/em>LC\u3068\u306f?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Pro&nbsp;<em>EZ<\/em>LC Chromatogram Modeler\u306f\u3001\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08LC\uff09\u306b\u7279\u5316\u3057\u3066\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4f5c\u6210\u3067\u304d\u308b\u5148\u9032\u7684\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002\u3053\u306e\u7121\u6599\u30aa\u30f3\u30e9\u30a4\u30f3\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\u3092\u4f7f\u3048\u3070\u3001\u5bfe\u8c61\u6210\u5206\u3092\u5316\u5408\u7269\u30af\u30e9\u30b9\u304b\u3089\u9078\u629e\u3059\u308b\u3060\u3051\u3067\u3001\u30ab\u30e9\u30e0\u3084\u5206\u96e2\u6761\u4ef6\u306e\u60c5\u5831\u3092\u5373\u5ea7\u306b\u5165\u624b\u3067\u304d\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u5206\u6790\u6761\u4ef6\u306e\u6700\u9069\u5316\u3092\u884c\u3046\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<em>EZ<\/em>LC Modeler\u306fRestek\u306e\u6280\u8853\u8005\u306b\u3088\u3063\u3066\u65e2\u306b\u751f\u6210\u3055\u308c\u305f\u5805\u7262\u306a\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3068\u5b9f\u9a13\u30c7\u30fc\u30bf\u306b\u57fa\u3065\u3044\u3066\u4f5c\u6210\u3055\u308c\u305f\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u30c4\u30fc\u30eb\u306e\u305f\u3081\u3001\u30e6\u30fc\u30b6\u30fc\u304c\u8ffd\u52a0\u3067\u5b9f\u9a13\u30c7\u30fc\u30bf\u3092\u5165\u529b\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 id=\"mokuji2\" class=\"wp-block-heading\">Pro <em>EZ<\/em>LC\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9<\/h2>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji3\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-1\" style=\"font-size:22px\">\u5316\u5408\u7269<strong>(Compounds)<\/strong>\u30bf\u30d6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Pro&nbsp;<em>EZ<\/em>LC Modeler\u3067\u306e\u4f5c\u696d\u306f\u3001 <strong>\u5316\u5408\u7269<\/strong>\u30bf\u30d6\u304b\u3089\u958b\u59cb\u3057\u307e\u3059\u3002\u30e6\u30fc\u30b6\u30fc\u306f\u30e2\u30c7\u30eb\u5316\u3059\u308b\u5316\u5408\u7269\u3068\u56fa\u5b9a\u76f8\u3092\u9078\u629e\u3057\u307e\u3059\u304c\u3001\u9078\u629e\u3057\u305f\u30e2\u30c7\u30eb\u306b\u3088\u3063\u3066\u9078\u3079\u308b\u5316\u5408\u7269\u304c\u7570\u306a\u308b\u306e\u3067\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u4f5c\u696d\u30bb\u30c3\u30b7\u30e7\u30f3\u3092\u7d42\u4e86\u3057\u305f\u308a\u3001\u4fdd\u5b58\u3057\u305f\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u30ed\u30fc\u30c9\u3057\u305f\u308a\u3001\u307e\u305f\u306fWeb\u753b\u9762\u81ea\u4f53\u3092\u30ea\u30ed\u30fc\u30c9\u3057\u305f\u308a\u3059\u308b\u3068\u3001\u9078\u629e\u3057\u305f\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306f\u30af\u30ea\u30a2\u3055\u308c\u308b\u306e\u3067\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u9078\u629e\u3057\u305f\u5316\u5408\u7269\u306e\u3044\u305a\u308c\u304b\u304c\u540c\u91cd\u4f53\u3067\u3042\u308b\u5834\u5408\u3001Modeler\u306b\u3088\u3063\u3066\u81ea\u52d5\u7684\u306b\u5206\u96e2\u306e\u305f\u3081\u306e\u30d5\u30e9\u30b0\u304c\u7acb\u3066\u3089\u308c\u307e\u3059\u3002\u307e\u305f\u3001\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u4f5c\u6210\u3055\u308c\u308b\u3068\u3001 <strong>\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc<\/strong>\u30a8\u30ea\u30a2\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5206\u96e2\u3092\u3055\u3089\u306b\u6700\u9069\u5316\u3059\u308b\u5834\u5408\u306f\u3001<strong><a href=\"#top-of-page\">\u5206\u6790\u6761\u4ef6(Condition)<\/a><\/strong>\u30bf\u30d6\u304b\u3089\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u3067\u306f\u3001\u5b9f\u969b\u306e\u30d5\u30ed\u30fc\u3092\u8a73\u3057\u304f\u8aac\u660e\u3057\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u307e\u305a<strong>\u5316\u5408\u7269\u30af\u30e9\u30b9(Compound Class)<\/strong>\u306e\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30e1\u30cb\u30e5\u30fc\u304b\u3089\u5316\u5408\u7269\u30af\u30e9\u30b9\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3059\u308b\u3068\u3001\u305d\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u767b\u9332\u3055\u308c\u305f\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306e\u30ea\u30b9\u30c8\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5316\u5408\u7269\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001\u30ea\u30b9\u30c8\u5185\u3067\u305d\u306e\u5316\u5408\u7269\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u30a8\u30f3\u30c8\u30ea\u30fc\u3057\u307e\u3059\u3002\u306a\u304a\u3001\u30a8\u30f3\u30c8\u30ea\u30fc\u3055\u308c\u305f\u5316\u5408\u7269\u3092\u518d\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u9078\u629e\u304c\u89e3\u9664\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"394\" height=\"466\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-1-figure-article-gnot3918-01.jpg\" alt=\"\" class=\"wp-image-30009\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-1-figure-article-gnot3918-01.jpg 394w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-1-figure-article-gnot3918-01-254x300.jpg 254w\" sizes=\"auto, (max-width: 394px) 100vw, 394px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\" style=\"font-size:18px\"><em>\u30e2\u30c7\u30eb\u5316\u3059\u308b\u5316\u5408\u7269\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001\u305d\u306e\u5316\u5408\u7269\u306e\u884c\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u691c\u7d22(Search)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u5316\u5408\u7269\u540d\u307e\u305f\u306fCAS\u756a\u53f7\u3067\u30ea\u30b9\u30c8\u3092\u3059\u3070\u3084\u304f\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3067\u304d\u307e\u3059\u3002\u5316\u5408\u7269\u540d\u306e\u4e00\u822c\u7684\u306a\u540c\u7fa9\u8a9e\u3067\u3082\u691c\u7d22\u3067\u304d\u307e\u3059\u3002 \u5316\u5408\u7269\u306e\u884c\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3001\u5316\u5408\u7269\u3092\u9078\u629e\u3057\u3066\u30e2\u30c7\u30eb\u4f5c\u6210\u5bfe\u8c61\u6210\u5206\u3068\u3057\u3066\u8ffd\u52a0\u3057\u307e\u3059\u3002<strong>\u691c\u7d22<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u306e\u300cX\u300d\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u3001\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u304c\u89e3\u9664\u3055\u308c\u3001\u5143\u306e\u30ea\u30b9\u30c8\u306b\u623b\u308a\u307e\u3059\u3002<em> <strong>\u3053\u306e\u65b9\u6cd5\u3067\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3092\u89e3\u9664\u3057\u3066\u3082\u3001\u65e2\u5b58\u306e\u9078\u629e\u9805\u76ee\u304c\u524a\u9664\u3055\u308c\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/strong><\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"394\" height=\"147\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-2-figure-article-gnot3918-02.jpg\" alt=\"\" class=\"wp-image-30015\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-2-figure-article-gnot3918-02.jpg 394w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-2-figure-article-gnot3918-02-300x112.jpg 300w\" sizes=\"auto, (max-width: 394px) 100vw, 394px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\" style=\"font-size:18px\"><em>\u691c\u7d22\u30d5\u30a3\u30fc\u30eb\u30c9\u3067\u3001\u5316\u5408\u7269\u306e\u540d\u524d\u307e\u305f\u306fCAS\u756a\u53f7\u3067\u691c\u7d22\u3057\u307e\u3059\u3002<\/em><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"166\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-3-figure-article-gnot3918-03.jpg\" alt=\"\" class=\"wp-image-30021\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-3-figure-article-gnot3918-03.jpg 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-3-figure-article-gnot3918-03-300x125.jpg 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-4 wp-block-paragraph\" style=\"font-size:18px\"><em>\u30e9\u30a4\u30d6\u30e9\u30ea\u5185\u306e\u5316\u5408\u7269\u306f\u3001\u4e00\u822c\u7684\u306a\u540c\u7fa9\u8a9e\u3067\u691c\u7d22\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u884c\u5185\u306b\u9752\u3044\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u304c\u3042\u308b\u5316\u5408\u7269\u306f\u3001\u9078\u629e\u30ea\u30b9\u30c8\u5185\u306e\u5225\u306e\u5316\u5408\u7269\u306e\u540c\u91cd\u4f53\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<strong>Modeler\u306f\u3001\u9078\u629e\u3055\u308c\u305f\u540c\u91cd\u4f53\u306e\u5206\u96e2\u304c\u53ef\u80fd\u3068\u306a\u308b\u3088\u3046\u3001\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4f5c\u6210\u3057\u307e\u3059\u3002<\/strong>\u691c\u51fa\u5668\u8a2d\u5b9a\u304cMS\u306e\u5834\u5408\u3001\u540c\u91cd\u4f53\u306f\u3042\u3089\u304b\u3058\u3081\u9078\u629e\u3055\u308c\u307e\u3059\u304c\u3001\u691c\u51fa\u5668\u8a2d\u5b9a\u304cUV\u306e\u5834\u5408\u3001\u540c\u91cd\u4f53\u306f\u5206\u96e2\u5bfe\u8c61\u3068\u3057\u3066\u4e8b\u524d\u9078\u629e\u3055\u308c\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u540c\u91cd\u4f53\u306e\u5206\u96e2\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001\u5206\u96e2\u5bfe\u8c61\u3068\u3059\u308b\u540c\u91cd\u4f53\u306e\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u624b\u52d5\u3067\u30aa\u30f3\u306b\u3059\u308b\u304b\u3001\u300c\u3059\u3079\u3066\u6307\u5b9a(Target All)\u300d\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"394\" height=\"472\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-4-figure-article-gnot3918-04.jpg\" alt=\"\" class=\"wp-image-30027\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-4-figure-article-gnot3918-04.jpg 394w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-4-figure-article-gnot3918-04-250x300.jpg 250w\" sizes=\"auto, (max-width: 394px) 100vw, 394px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-5 wp-block-paragraph\" style=\"font-size:18px\"><em>\u691c\u51fa\u5668\u8a2d\u5b9a\u304cMS\u306e\u5834\u5408\u3001\u540c\u91cd\u4f53\u5316\u5408\u7269\u306f\u81ea\u52d5\u7684\u306b\u5206\u96e2\u5bfe\u8c61\u3068\u306a\u308a\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u7279\u5b9a\u306e\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u5206\u96e2\u304c\u4e0d\u8981\u306a\u5834\u5408\u306f\u3001\u305d\u306e\u5316\u5408\u7269\u306e\u9752\u3044\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u5206\u96e2\u5bfe\u8c61\u304b\u3089\u5916\u3057\u307e\u3059\uff08\u5316\u5408\u7269\u81ea\u4f53\u306e\u9078\u629e\u304c\u89e3\u9664\u3055\u308c\u306a\u3044\u9650\u308a\u3001\u540c\u91cd\u4f53\u306f\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30d3\u30e5\u30fc\u306b\u8868\u793a\u3055\u308c\u307e\u3059\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"587\" height=\"694\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-5-suzuki.jpg\" alt=\"\" class=\"wp-image-11715\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-5-suzuki.jpg 587w, https:\/\/discover.restek.com\/wp-content\/uploads\/30-5-suzuki-254x300.jpg 254w\" sizes=\"auto, (max-width: 587px) 100vw, 587px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-6 wp-block-paragraph\" style=\"font-size:18px\"><em>\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3001\u5316\u5408\u7269\u306e\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u5bfe\u8c61\u30fb\u5bfe\u8c61\u5916\u3092\u5207\u308a\u66ff\u3048\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5206\u96e2\u5bfe\u8c61\u306e\u5316\u5408\u7269\u3092\u5909\u66f4\u3059\u308b\u3068\u3001\u5206\u6790\u6642\u9593\u304c\u5927\u304d\u304f\u7570\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u307e\u305f\u3001\u5bfe\u8c61\u5316\u5408\u7269\u306e\u5206\u96e2\u3092\u5f97\u308b\u305f\u3081\u306b\u4ed6\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u304c\u72a0\u7272\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308b\u305f\u3081\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u306e\u305f\u3081\u3001\uff08\u691c\u51fa\u5668\u8a2d\u5b9a\u304cMS\u306e\u5834\u5408\uff09\u5206\u96e2\u3059\u3079\u304d<em>\u3059\u3079\u3066\u306e<\/em>\u540c\u91cd\u4f53\u5316\u5408\u7269\u3092\u5fc5\u305a\u5206\u96e2\u5bfe\u8c61\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5316\u5408\u7269\u306e\u9078\u629e\u3092\u3059\u3079\u3066\u89e3\u9664\u3059\u308b\u306b\u306f\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u4e0b\u306b\u3042\u308b\uff08\u6570\u5b57\u3001\u4e0a\u56f3\u3067\u306f\uff14\uff09<strong>\u6210\u5206\u9078\u629e(Compounds Selected)<\/strong>\u306e\u53f3\u5074\u306b\u3042\u308b<strong>\u30af\u30ea\u30a2(Clear)<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u304b\u3001<strong>\u5316\u5408\u7269\u30af\u30e9\u30b9<\/strong>\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30e1\u30cb\u30e5\u30fc\u304b\u3089\u65b0\u3057\u3044\u5316\u5408\u7269\u30af\u30e9\u30b9\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u540c\u91cd\u4f53\u306e\u5206\u96e2\u5bfe\u8c61\u5316\u5408\u7269\u3092\u3059\u3079\u3066\u89e3\u9664\u3059\u308b\u306b\u306f\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u4e0b\u306b\u3042\u308b\uff08\u6570\u5b57\u3001\u4e0a\u56f3\u3067\u306f\uff10\uff09<strong>\u306e\u540c\u91cd\u4f53\u3092\u5206\u96e2(Isobars To Resolve)<\/strong>\u306e\u53f3\u5074\u306b\u3042\u308b<strong>\u30af\u30ea\u30a2(Clear)<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3053\u3068\u3067\u3059\u3079\u3066\u89e3\u9664\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u76ee\u7684\u306e\u5316\u5408\u7269\u3092\u9078\u629e\u3057\u305f\u3089\u3001<strong>\u56fa\u5b9a\u76f8(Phase)<\/strong>\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30e1\u30cb\u30e5\u30fc\u304b\u3089\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u9078\u629e\u3057\u305f\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u3088\u308a\u307e\u3059\u304c\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u306e<strong>\u691c\u51fa\u5668(Detector)<\/strong>\u306fMS\u307e\u305f\u306fUV\u306e\u3044\u305a\u308c\u304b\u3068\u306a\u308a\u307e\u3059\u3002\uff08MS\u3067\u3042\u308c\u3070\u3001\u5206\u5b50\u91cf\u3084\u30d7\u30ec\u30ab\u30fc\u30b5\u30a4\u30aa\u30f3\u3092\u57fa\u306b\u3057\u3066\u540c\u91cd\u4f53\u5316\u5408\u7269\u3092\u4e3b\u306a\u5206\u96e2\u5bfe\u8c61[Rs]\u3068\u3057\u307e\u3059\u3002\u4e00\u65b9UV\u3067\u306f\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306e\u5206\u96e2 [Rs]\u306b\u7126\u70b9\u3092\u5f53\u3066\u307e\u3059\u304c\u3001\u9078\u629e\u3057\u305f\u540c\u91cd\u4f53\u3092\u5206\u96e2\u5bfe\u8c61 [Rs]\u3068\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\uff09\u6b21\u306b\u3001<strong>\u30e2\u30c7\u30eb\u751f\u6210(Generate Model)<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3001\u9078\u629e\u3057\u305f\u5316\u5408\u7269\u306e\u30e2\u30c7\u30ea\u30f3\u30b0\u306b\u9032\u307f\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u306a\u304a\u3001\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\uff08\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff09\u306f\u3001\u30a2\u30d7\u30ea\u306e<strong>\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc<\/strong>\u30a8\u30ea\u30a2\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji4\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-7\" style=\"font-size:22px\">\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u306e\u53f3\u30d1\u30cd\u30eb\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30d3\u30e5\u30fc\u306f\u3001<strong>My&nbsp;<em>EZ<\/em>LC<\/strong>\u306e\u6a2a\u306b\u3042\u308b&lt;&lt;\u77e2\u5370\u3092\u4f7f\u3048\u3070\u62e1\u5f35\uff08\u30bf\u30d6\u3092\u975e\u8868\u793a\uff09\u3057\u3066\u8868\u793a\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u30bf\u30d6\u3092\u518d\u5ea6\u8868\u793a\u3059\u308b\u306b\u306f\u3001\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30b9\u306e\u5de6\u4e0a\u9685\u306b\u3042\u308b&gt;&gt;\u77e2\u5370\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"846\" height=\"411\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-6-figure-article-gnot3918-06.jpg\" alt=\"\" class=\"wp-image-30033\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-6-figure-article-gnot3918-06.jpg 846w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-6-figure-article-gnot3918-06-300x146.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Y30-6-figure-article-gnot3918-06-768x373.jpg 768w\" sizes=\"auto, (max-width: 846px) 100vw, 846px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-8 wp-block-paragraph\" style=\"font-size:18px\"><em>\u62e1\u5927\u3055\u308c\u305f\u30d3\u30e5\u30fc\u306f\u3001\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u5370\u5237\u3059\u308b\u306e\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u62e1\u5927\u3059\u308b\u306b\u306f\u3001\u30de\u30a6\u30b9\u3067\u8a72\u5f53\u9818\u57df\u3092\u30af\u30ea\u30c3\u30af\uff06\u30c9\u30e9\u30c3\u30af\u3057\u307e\u3059\uff08\u30bf\u30d6\u30ec\u30c3\u30c8\u306f\u3001\u6307\u3067\u30bf\u30c3\u30d7\uff06\u30c9\u30e9\u30c3\u30b0\uff09\u3002\u3055\u3089\u306b\u62e1\u5927\u3059\u308b\u5834\u5408\u306b\u3082\u540c\u69d8\u306e\u64cd\u4f5c\u304c\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u62e1\u5927\u3092\u89e3\u9664\u3059\u308b\u306b\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u30c0\u30d6\u30eb\u30af\u30ea\u30c3\u30af\uff08\u30c0\u30d6\u30eb\u30bf\u30c3\u30d7\uff09\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"659\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-07a.gif\" alt=\"\" class=\"wp-image-22545\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-9 wp-block-paragraph\" style=\"font-size:18px\"><em>\u3042\u308b\u9818\u57df\u3092\u30af\u30ea\u30c3\u30af\uff06\u30c9\u30e9\u30c3\u30b0\u3059\u308b\u3068\u3001\u305d\u306e\u9818\u57df\u304c\u30ba\u30fc\u30e0\u3055\u308c\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30d4\u30fc\u30af\u756a\u53f7\uff08\u30c7\u30b9\u30af\u30c8\u30c3\u30d7\u30d6\u30e9\u30a6\u30b6\u7248\u306e\u307f\uff09\u306b\u30ab\u30fc\u30bd\u30eb\u3092\u5408\u308f\u305b\u308b\u3068\u3001\u4fdd\u6301\u6642\u9593\uff08tR\uff09\u3001\u5206\u96e2\u5ea6\uff08\u6700\u3082\u8fd1\u3044\u30d4\u30fc\u30af\u3078\u306e\u5206\u96e2\u5ea6\u3001RS\uff09\u3001\u6eb6\u51fa%B\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u5171\u6eb6\u51fa\u30d4\u30fc\u30af\u306e\u5834\u5408\u306f\u3001\u3059\u3079\u3066\u306e\u5171\u6eb6\u51fa\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3053\u308c\u3089\u306e\u5024\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u307e\u305f\u3001\u540c\u91cd\u4f53\u5316\u5408\u7269\u3092\u542b\u3080\u5206\u96e2\u3067\u306f\u3001\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u4e0b\u306b\u3042\u308b<strong>\u9078\u629e\u53ef\u80fd\u306a\u540c\u91cd\u4f53(Available Isobars)<\/strong>\u30e1\u30cb\u30e5\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u540c\u91cd\u4f53\u306e\u5206\u96e2\u306e\u78ba\u8a8d\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u5404\u540c\u91cd\u4f53\u306e<strong>Critical Pair<\/strong>\uff08\u4e0b\u8a18<strong>\u6ce8<\/strong>\u53c2\u7167\uff09\u306f\u3001\u5206\u96e2\u5ea6\u306e\u4f4e\u3044\u3082\u306e\u304b\u3089\u9806\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002Rs=1.5\uff08\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\uff09\u4ee5\u4e0a\u306e\u5206\u96e2\u5ea6\u3092\u6301\u3064\u540c\u91cd\u4f53\u306eCritical Pair\u306f\u3001\u7dd1\u8272\u306e\u30c8\u30ec\u30fc\u30b9\u3068\u3057\u3066\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u540c\u91cd\u4f53\u306eCritical Pair\u9593\u306e\u5206\u96e2\u5ea6\u304cRs=1.5\u3092\u4e0b\u56de\u308b\u3068\u3001\u30c8\u30ec\u30fc\u30b9\u306f\u5171\u6eb6\u51fa\u306e\u5ea6\u5408\u3044\u306b\u5fdc\u3058\u3066\u30aa\u30ec\u30f3\u30b8\u307e\u305f\u306f\u8d64\u3067\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"779\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-08a-779x1024.png\" alt=\"\" class=\"wp-image-22557\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-08a-779x1024.png 779w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-08a-228x300.png 228w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-08a-768x1009.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-08a.png 939w\" sizes=\"auto, (max-width: 779px) 100vw, 779px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-10 wp-block-paragraph\" style=\"font-size:18px\"><em>\u9078\u629e\u53ef\u80fd\u306a\u540c\u91cd\u4f53\u3067\u9078\u629e\u3059\u308b\u3068\u3001\u540c\u91cd\u4f53\u306e\u5206\u96e2\u306e\u78ba\u8a8d\u304c\u5bb9\u6613\u306b\u3067\u304d\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u6ce8: <\/strong>\u4e0a\u56f3\u306e\u8272\u4ed8\u304d\u306e\u30c8\u30ec\u30fc\u30b9\u306e\u3088\u3046\u306b\u30013\u3064\u4ee5\u4e0a\u306e\u540c\u91cd\u4f53\u5316\u5408\u7269\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u3001\u6700\u3082\u8fd1\u63a5\u3057\u3066\u6eb6\u51fa\u3059\u308b2\u3064\u306e\u5316\u5408\u7269\u306e\u307f\u304c<strong>\u9078\u629e\u53ef\u80fd\u306a\u540c\u91cd\u4f53<\/strong>\u306e\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30ea\u30b9\u30c8\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u306e2\u3064\u306e\u5316\u5408\u7269\u306f\u3001\u540c\u3058m\/z\u30a4\u30aa\u30f3\u3092\u5171\u6709\u3059\u308b\u300cCritical Pair\u300d\u3068\u3057\u3066\u5b9a\u7fa9\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u306b\u306f\u3001\u4fdd\u6301\u6642\u9593(tR\u3001\u5206)\u3001\u5206\u96e2\u5ea6(\u6700\u3082\u8fd1\u3044\u30d4\u30fc\u30af\u3078\u306e\u5206\u96e2\u5ea6Rs)\u3001\u30d4\u30fc\u30af\u5e45(\u5206)\u3001Exit %B\u3001ESI\u30a4\u30aa\u30f3\u5316\u30e2\u30fc\u30c9\u3001Precursor \u30a4\u30aa\u30f3\u3068\u5b9a\u91cfProduct\u30a4\u30aa\u30f3(m\/z)\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<strong>\u9078\u629e\u53ef\u80fd\u306a\u540c\u91cd\u4f53<\/strong>\u30ea\u30b9\u30c8\u304b\u3089\u9078\u629e\u3057\u305f\u540c\u91cd\u4f53\u306f\u3001\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3067\u30cf\u30a4\u30e9\u30a4\u30c8\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji5\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-11\" style=\"font-size:22px\">\u5206\u6790\u6761\u4ef6(Conditions)\u30bf\u30d6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Modeler\u304c\u521d\u671f\u7d50\u679c\u3092\u8868\u793a\u3057\u305f\u3089\u3001<strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u3067\u30e2\u30c7\u30eb\u306e\u6761\u4ef6\u3092\u3055\u3089\u306b\u8abf\u6574\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<em>EZ<\/em>LC Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308b\u4e0a\u3067\u306e\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u306f\u3001Modeler\u304c\u614e\u91cd\u306a\u7d50\u679c\u3092\u63d0\u4f9b\u3059\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u304a\u308a\u3001\u5206\u96e2\u304c\u5341\u5206\u3067\u306a\u3044\u7d50\u679c\u304c\u793a\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u5206\u6790\u6761\u4ef6\u30bf\u30d6\u3067\u5206\u96e2\u3092\u6700\u9069\u5316\u3057\u305f\u5f8c\u3067\u3082\u3001\u30e2\u30c7\u30eb\u5185\u306b\u5171\u6eb6\u51fa\u3059\u308b\u6210\u5206\u304c\u6b8b\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5b9f\u969b\u306e\u30e9\u30dc\u3067\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u6761\u4ef6\u3092\u518d\u73fe\u3057\u3066\u307f\u308b\u3068\u3001\u5206\u96e2\u304c\u53ef\u80fd\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u8ffd\u52a0\u306e\u5909\u6570\uff08\u4f8b\u3048\u3070\u3001\u79fb\u52d5\u76f8\u6dfb\u52a0\u5264\u306a\u3069\uff09\u3092\u691c\u8a0e\u3059\u308b\u3053\u3068\u3082\u3001\u5206\u96e2\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306e\u6709\u52b9\u306a\u624b\u6bb5\u3067\u3059\u3002\u30e9\u30dc\u3067\u672a\u5206\u96e2\u306e\u540c\u91cd\u4f53\u3092\u5206\u96e2\u3059\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3915-ja\/japan-accelerate-lc-ms-ms-method-development-using-the-pro-ezlc-chromatogram-modeler\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNAR3915-JA\/japan-accelerate-lc-ms-ms-method-development-using-the-pro-ezlc-chromatogram-modeler\">\u6280\u8853\u8a18\u4e8b<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u3067\u306f\u3001Critical Pair\u5206\u96e2\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u3001\u521d\u671f\u6761\u4ef6\u3092\u6700\u9069\u5316\u3059\u308b\u305f\u3081\u306b\u4ee5\u4e0b\u306e\u5909\u66f4\u3092\u884c\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306e\u5909\u66f4<\/li>\n\n\n\n<li style=\"font-size:16px\">\u30e6\u30fc\u30b6\u30fc\u304c\u4f7f\u7528\u3057\u3066\u3044\u308b\u88c5\u7f6e\/\u30b7\u30b9\u30c6\u30e0\u306b\u56fa\u6709\u306eDwell Volume\u3068\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf(Extra-Column Volume)\u306e\u8abf\u6574<\/li>\n\n\n\n<li style=\"font-size:16px\">\u79fb\u52d5\u76f8(Mobile Phase)\u304a\u3088\u3073\u30ab\u30e9\u30e0\u6e29\u5ea6\u306e\u5909\u66f4<br>\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">\u7279\u5b9a\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u3067\u306f\u79fb\u52d5\u76f8\u6dfb\u52a0\u5264\u6fc3\u5ea6\u306e\u5909\u66f4\u304c\u53ef\u80fd\uff08\u4f8b\u3048\u3070\u3001\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u300c\u6eb6\u5a92 A\u300d\u306e\u7de9\u885d\u6db2\u6fc3\u5ea6\uff08mM\uff09\uff09<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"601\" height=\"238\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-8-suzuki.png\" alt=\"\" class=\"wp-image-11721\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-8-suzuki.png 601w, https:\/\/discover.restek.com\/wp-content\/uploads\/30-8-suzuki-300x119.png 300w\" sizes=\"auto, (max-width: 601px) 100vw, 601px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">\u30de\u30eb\u30c1\u30b9\u30c6\u30c3\u30d7\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u4f5c\u6210<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u6700\u9069\u5316\u306e\u305f\u3081\u306b\u5206\u6790\u6761\u4ef6\u3092\u5909\u66f4\u3059\u308b\u6bce\u306b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u304c\u66f4\u65b0\u3055\u308c\u308b\u305f\u3081\u3001\u30e6\u30fc\u30b6\u30fc\u306f\u5404\u5909\u66f4\u304c\u5168\u4f53\u7684\u306a\u5206\u96e2\u306b\u3069\u306e\u3088\u3046\u306b\u5f71\u97ff\u3059\u308b\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"428\" height=\"912\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-9-suzuki.png\" alt=\"\" class=\"wp-image-11727\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/30-9-suzuki.png 428w, https:\/\/discover.restek.com\/wp-content\/uploads\/30-9-suzuki-141x300.png 141w\" sizes=\"auto, (max-width: 428px) 100vw, 428px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-12 wp-block-paragraph\" style=\"font-size:18px\"><em>\u5206\u6790\u6761\u4ef6(Conditions)\u30bf\u30d6\u3067\u30e2\u30c7\u30eb\u306e\u6761\u4ef6\u3092\u5909\u66f4\u3057\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-13\" style=\"font-size:20px\"><strong>\u30ab\u30e9\u30e0(Column)<\/strong><\/h4>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-5-color has-text-color has-link-color wp-elements-14\" style=\"font-size:19px\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-theme-palette-2-color\">\u9577\u3055(Length)<\/mark><\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">LC\u30ab\u30e9\u30e0\u306e\u9577\u3055\u3092\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\uff08mm\uff09\u5358\u4f4d\u3067\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-15\" style=\"font-size:19px\">\u5185\u5f84(Inner Diameter)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">LC\u30ab\u30e9\u30e0\u306e\u5185\u5f84\uff08ID\uff09\u3092\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\uff08mm\uff09\u3067\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-16\" style=\"font-size:19px\">\u7c92\u5b50\u5f84(Particle Size)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">LC\u30ab\u30e9\u30e0\u306e\u7c92\u5b50\u5f84\u3092\u30de\u30a4\u30af\u30ed\u30e1\u30fc\u30c8\u30eb\uff08\u03bcm\uff09\u3067\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-17\" style=\"font-size:19px\">\u9078\u629e\u53ef\u80fd\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba(Available Columns)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3059\u308b\u306b\u306f\u3001<strong>\u9078\u629e\u53ef\u80fd\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba<\/strong>\u30ea\u30b9\u30c8\u304b\u3089\u4ee3\u66ff\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u304c\u30ea\u30b9\u30c8\u306b\u8868\u793a\u3055\u308c\u308b\u308f\u3051\u3067\u306f\u306a\u3044\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u306e\u307f\u306e\u30ad\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u30ea\u30b9\u30c8\u304c\u5404\u5316\u5408\u7269\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-18\" style=\"font-size:19px\">\u30dc\u30ea\u30e5\u30fc\u30e0\u52b9\u679c(Volume Effects)<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u88c5\u7f6e\u306b\u304a\u3051\u308bDwell Volume\u3068\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf(Extra-Column Volume)\u3092\u5165\u529b\u3059\u308b\u3068\u3001\u305d\u306e\u88c5\u7f6e\u306b\u9069\u3057\u305f\u30e2\u30c7\u30eb\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-19\" style=\"font-size:19px\">Dwell Volume<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u79fb\u52d5\u76f8\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u5909\u5316\u306f\u5373\u5ea7\u306b\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u306a\u305c\u306a\u3089\u3070\u3001\u65b0\u3057\u3044\u7d44\u6210\u304c\u30b7\u30b9\u30c6\u30e0\u5185\u3092\u79fb\u52d5\u3057\u3066\u30ab\u30e9\u30e0\u306b\u5230\u9054\u3059\u308b\u306b\u306f\u6642\u9593\u304c\u5fc5\u8981\u3060\u304b\u3089\u3067\u3059\u3002\u3053\u306e\u5909\u5316\u306b\u5fc5\u8981\u306a\u30b7\u30b9\u30c6\u30e0\u5bb9\u91cf\u306f\u88c5\u7f6e\u306e\u300cdwell volume\u300d\u3068\u547c\u3070\u308c\u3001\u6eb6\u5a92\u304c\u6df7\u5408\u3055\u308c\u308b\u30dd\u30a4\u30f3\u30c8\u304b\u3089\u30ab\u30e9\u30e0\u30d8\u30c3\u30c9\u307e\u3067\u306e\u6d41\u8def\u306e\u9577\u3055\u3068\u5185\u5f84\u306b\u542b\u307e\u308c\u308b\u5bb9\u91cf\u3068\u3057\u3066\u5b9a\u7fa9\u3055\u308c\u307e\u3059\u3002\u88c5\u7f6e\u306edwell volume\u306f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30e1\u30bd\u30c3\u30c9\u306e\u4fdd\u6301\u6642\u9593\u306b\u5f71\u97ff\u3057\u3001\u65e9\u671f\u6eb6\u51fa\u5316\u5408\u7269\u306e\u9078\u629e\u6027\u306b\u3082\u5f71\u97ff\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001dwell volume\u3092\u8003\u616e\u3059\u308b\u3053\u3068\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u6210\u529f\u3055\u305b\u308b\u305f\u3081\u306b\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u901a\u5e38\u3001\u88c5\u7f6e\u306edwell volume\u306f\u3001\u30df\u30ad\u30b5\u30fc\u307e\u305f\u306f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30dd\u30fc\u30b7\u30e7\u30cb\u30f3\u30b0\u30d0\u30eb\u30d6\uff084\u5143\u7cfb\u30dd\u30f3\u30d7\u306e\u5834\u5408\uff09\u306e\u3044\u305a\u308c\u304b\u3092\u30b9\u30bf\u30fc\u30c8\u5730\u70b9\u3068\u3057\u3001\u30df\u30ad\u30b5\u30fc\u304b\u3089\u6ce8\u5165\u30d0\u30eb\u30d6\u307e\u3067\u306e\u30c1\u30e5\u30fc\u30d6\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3001\u6ce8\u5165\u30d0\u30eb\u30d6\u304b\u3089\u30ab\u30e9\u30e0\u307e\u3067\u306e\u30c1\u30e5\u30fc\u30d6\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u30c1\u30e5\u30fc\u30d6\u3092\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u3057\u305f\u5834\u5408\u3001\u30c1\u30e5\u30fc\u30d6\u306e\u9577\u3055\u3068\u5185\u5f84\u304b\u3089\u5bb9\u91cf\u3092\u7c21\u5358\u306b\u8a08\u7b97\u3067\u304d\u308b\u30aa\u30f3\u30e9\u30a4\u30f3\u8a08\u7b97\u6a5f\u304c\u591a\u6570\u3042\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306f\u305d\u306e\u4e00\u3064\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.omnicalculator.com\/construction\/pipe-volume\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.omnicalculator.com\/construction\/pipe-volume<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u88c5\u7f6e\u306edwell volume\u3092\u8abf\u3079\u308b\u306b\u306f\u3001\u88c5\u7f6e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u53c2\u7167\u3059\u308b\u304b\u3001\u88c5\u7f6e\u30e1\u30fc\u30ab\u30fc\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u88c5\u7f6e\u56fa\u6709\u306edwell volume\u5024\u304c\u5165\u624b\u3067\u304d\u306a\u3044\u5834\u5408\u306f\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u9069\u7528\u3059\u308b\u30c7\u30d5\u30a9\u30eb\u30c8\u5024\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u4fdd\u5b88\u7684\u306a\u30e2\u30c7\u30eb\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u4fdd\u6301\u6642\u9593\u306e\u4e88\u6e2c\u306f\u5f71\u97ff\u3092\u53d7\u3051\u308b\u53ef\u80fd\u6027\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u305d\u308c\u3067\u3082\u5b9f\u969b\u306b\u89b3\u5bdf\u3055\u308c\u308b\u4fdd\u6301\u6642\u9593\u306f\u8fd1\u4f3c\u5024\u3092\u793a\u3059\u306f\u305a\u3067\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-20\" style=\"font-size:19px\">\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u52b9\u679c(Extra Column Volume Effect)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">&nbsp;LC\u88c5\u7f6e\u306e\u4ee5\u4e0b\u306e\u7269\u7406\u7684\u306a\u69cb\u6210\u8981\u7d20\u306b\u3088\u3063\u3066\u3001\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\uff08Extra-Column Volume: ECV\uff09\u306f\u6c7a\u307e\u308a\u307e\u3059\u3002\u30cb\u30fc\u30c9\u30eb\u30b7\u30fc\u30c8\u3001\u6ce8\u5165\u91cf\u3001\u6ce8\u5165\u30d0\u30eb\u30d6\u3001\u30d7\u30ec\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\u3001\u30d7\u30ec\u30d2\u30fc\u30bf\u30fc\u3001\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u30c1\u30e5\u30fc\u30d6\u304cECV\u306b\u5f71\u97ff\u3057\u307e\u3059\u3002\u30d5\u30ed\u30fc\u30bb\u30eb\u30d9\u30fc\u30b9\u306e\u691c\u51fa\u5668\u306e\u5834\u5408\u306f\u691c\u51fa\u5668\u30dc\u30ea\u30e5\u30fc\u30e0\u3082ECV\u3092\u6c7a\u3081\u308b\u69cb\u6210\u8981\u7d20\u3068\u306a\u308a\u307e\u3059\u3002ECV\u306b\u3088\u3063\u3066\u30d0\u30f3\u30c9\u5e45\u304c\u62e1\u5927\u3001\u3059\u306a\u308f\u3061\u89b3\u6e2c\u3055\u308c\u308b\u30d4\u30fc\u30af\u306e\u5e45\u304c\u62e1\u5927\u3057\u3001\u7d50\u679c\u7684\u306b\u30d4\u30fc\u30af\u5206\u96e2\u5ea6\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u3053\u306e\u30d4\u30fc\u30af\u5e45\u306e\u62e1\u5927\u306f\u300c\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u52b9\u679c\u300d\u307e\u305f\u306f \u300c\u30ab\u30e9\u30e0\u5916\u62e1\u6563\u300d\u3068\u547c\u3070\u308c\u307e\u3059\u3002ECV\u52b9\u679c\u306f\u3001\u30ab\u30e9\u30e0\u4ee5\u5916\u306e\u88c5\u7f6e\u306e\u6d41\u8def\u90e8\u5206\uff08\u30ab\u30e9\u30e0\u3092\u9664\u3044\u305f\u6ce8\u5165\u90e8\u304b\u3089\u691c\u51fa\u5668\u307e\u3067\u306e\u90e8\u5206\uff09\u306b\u304a\u3044\u3066\u3001\u5206\u6790\u6210\u5206\u306e\u30d0\u30f3\u30c9\u304c\u5e83\u304c\u3063\u3066\u3057\u307e\u3046\u90e8\u5206\u3001\u3064\u307e\u308a\u30ab\u30e9\u30e0\u4ee5\u5916\u306e\u8ffd\u52a0\u4f53\u7a4d\u3092\u8868\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u901a\u5e38\u3001\u4f53\u7a4d\u5358\u4f4d\u3067\u5831\u544a\u3055\u308c\u307e\u3059\u3002ECV\u52b9\u679c\u3092\u6b63\u78ba\u306b\u628a\u63e1\u3059\u308b\u3053\u3068\u3067\u3001Pro <em>EZ<\/em>LC Chromatogram Modeler\u306f\u30e2\u30c7\u30eb\u4f5c\u6210\u3092\u3059\u308b\u969b\u306b\u3001Critical Pair\u306e\u5206\u96e2\u3092\u3088\u308a\u6b63\u78ba\u306b\u8a08\u7b97\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u5404LC\u88c5\u7f6e\u306b\u306f\u305d\u308c\u305e\u308c\u56fa\u6709\u306eECV\u5024\u304c\u3042\u308b\u305f\u3081\u3001\u88c5\u7f6e\u306b\u4ed8\u5c5e\u3057\u3066\u3044\u308b\u30de\u30cb\u30e5\u30a2\u30eb\u306b\u305d\u306e\u5024\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001\u30e1\u30fc\u30ab\u30fc\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u88c5\u7f6e\u304c\u30e1\u30fc\u30ab\u30fc\u51fa\u8377\u6642\u306e\u69cb\u6210\u304b\u3089\u5909\u66f4\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3001<a href=\"https:\/\/ez.restek.com\/ezlc-mt\/en\/ja\" target=\"_blank\" rel=\"noopener\">Pro&nbsp;<em>EZ<\/em>LC Method Translator<\/a>\u3092\u4f7f\u7528\u3057\u3066ECV\u3092\u7b97\u51fa\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306f\u7570\u306a\u308a\u307e\u3059\u304c\u3001\u56fa\u5b9a\u76f8\u3068\u7c92\u5b50\u30bf\u30a4\u30d7\uff08SPP\u307e\u305f\u306fFPP\uff09\u304c\u540c\u3058\u30ab\u30e9\u30e0\u30922\u672c\u7528\u610f\u3057\u30012\u6210\u5206\u4ee5\u4e0a\u306e\u6df7\u5408\u30b5\u30f3\u30d7\u30eb\u306e\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u5206\u6790\u3092\u5b9f\u6a5f\u306b\u3066\u884c\u3044\u307e\u3059\u3002\u305d\u308c\u306b\u3088\u308a\u5f97\u3089\u308c\u305f\u7d50\u679c\uff08\u5206\u96e2\u5ea6\u3001\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u7b49\uff09\u3092Method Translator\u306b\u5165\u529b\u3057\u3001\u8a08\u7b97\u3055\u308c\u305f\u5206\u96e2\u5ea6\u306e\u5024\u304c\u89b3\u5bdf\u5024\u3068\u540c\u7b49\u306b\u306a\u308b\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\uff08ECV\uff09\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002ECV\u306e\u6a19\u6e96\u7684\u306a\u5024\u306f2\uff5e50 \u00b5L\u3067\u3059\u3002ECV\u52b9\u679c\u3092\u9069\u5207\u306b\u6c7a\u5b9a\u3057\u3066\u3082\u3001\u591a\u304f\u306e\u8981\u56e0\uff08\u975e\u30ac\u30a6\u30b9\u5206\u5e03\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u6eb6\u51fa%B\u306e\u308f\u305a\u304b\u306a\u30b7\u30d5\u30c8\u3001\u30ab\u30e9\u30e0\u4e0a\u306e\u8cea\u91cf\u306e\u30b9\u30b1\u30fc\u30ea\u30f3\u30b0\u30a8\u30e9\u30fc\u306a\u3069\uff09\u306b\u3088\u308a\u3001\u5206\u96e2\u5ea6\u306e\u8a08\u7b97\u5024\u306b\u504f\u308a\u304c\u751f\u3058\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u8a08\u7b97\u3055\u308c\u305f\u5206\u96e2\u5ea6\u306f\u3001\u89b3\u6e2c\u3055\u308c\u305f\u5206\u96e2\u5ea6\u306e\u00b125%\u4ee5\u5185\u3068\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u88c5\u7f6e\u56fa\u6709\u306eECV\u304c\u5206\u304b\u3089\u306a\u3044\u3001\u307e\u305f\u306f\u78ba\u8a8d\u3067\u304d\u306a\u3044\u5834\u5408\u3001Modeler\u306e\u30c7\u30d5\u30a9\u30eb\u30c8\u5024\u3092\u7528\u3044\u308b\u3068\u3053\u3068\u3067\u3001\u5f97\u3089\u308c\u308b\u7d50\u679c\u306f\u4fdd\u5b88\u7684\u306b\u306a\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u4e88\u6e2c\u3055\u308c\u308b\u4fdd\u6301\u6642\u9593\u306f\u4f9d\u7136\u3068\u3057\u3066\u9ad8\u3044\u76f8\u95a2\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u4e88\u6e2c\u3055\u308c\u308bCritical Pair\u306e\u5206\u96e2\u5ea6\u306e\u5024\u306f\u3001\u88c5\u7f6e\u56fa\u6709\u306e\u5024\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u307b\u3069\u6b63\u78ba\u306b\u306f\u306a\u3089\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji6\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-21\" style=\"font-size:22px\">PFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e t<sub>R<\/sub> \u3068\u5727\u529b\u3078\u306e\u5f71\u97ff<\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>t<sub>R<\/sub> \u3078\u306e\u5f71\u97ff:\u3000<\/strong>\u79fb\u52d5\u76f8\u30df\u30ad\u30b5\u30fc\u3068\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u9593\u306bPFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u6b63\u3057\u304f\u8a2d\u7f6e\u3059\u308b\u3053\u3068\u3067\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306e\u5e72\u6e09\u6210\u5206\u306e\u6eb6\u51fa\u3092\u9045\u5ef6\u3055\u305b\u3001\u30b5\u30f3\u30d7\u30eb\u4e2dPFAS\u306e\u6b63\u78ba\u306a\u6e2c\u5b9a\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u4fdd\u6301\u6642\u9593\uff08t<sub>R<\/sub>\uff09\u306b\u5bfe\u3059\u308b\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u5f71\u97ff\u306f\u3001<strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u306e<strong>\u30dc\u30ea\u30e5\u30fc\u30e0\u52b9\u679c(Volume Effect)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u306e<strong>Dwell Volume<\/strong>\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3067\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u300150 mm x 2.1 mm \u306e\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u5f71\u97ff\u306f\u3001<strong>Dwell Volume<\/strong>\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u7d040.09 mL \u5897\u3084\u3059\u3053\u3068\u3067\u88dc\u6b63\u3067\u304d\u307e\u3059\uff08\u4ee5\u4e0b\u306e\u8a08\u7b97\u3092\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">\u30ab\u30e9\u30e0\u5bb9\u91cf: V = \u03c0r<sup>2<\/sup>L<\/li>\n\n\n\n<li style=\"font-size:16px\">V = \u03c0 (1.05 mm)<sup>2<\/sup> \u00d7 50 mm \u2248 170 mm<sup>3<\/sup><\/li>\n\n\n\n<li style=\"font-size:16px\">170 mm<sup>3<\/sup> \u00d7 (0.001 mL \/ 1 mm<sup>3<\/sup>) \u2248 0.17 mL \u00d7 ~0.5* \u2248 0.09 mL<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30c7\u30d5\u30a9\u30eb\u30c8\u306e<strong>Dwell Volume<\/strong> 0.25 mL\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u5024\u30920.34 mL\u306b\u5909\u66f4\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">*\u5145\u586b\u30ab\u30e9\u30e0\u306e\u7a7a\u9699\u7387\u309250%\u3068\u60f3\u5b9a<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">50 mm x 2.1 mm \u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u5834\u5408\u3001\u6eb6\u51fa\u304c\u65e9\u3044\u5316\u5408\u7269\u3067\u306f\u7d046\u79d2\u3001\u6eb6\u51fa\u304c\u9045\u3044\u5316\u5408\u7269\u3067\u306f\u7d0412\u79d2\u306e\u4fdd\u6301\u6642\u9593(t<sub>R<\/sub>)\u306e\u5897\u52a0\u304c\u4e88\u60f3\u3055\u308c\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u5727\u529b\u3078\u306e\u5f71\u97ff:\u3000<\/strong>\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u88c5\u7f6e\u306e\u30b7\u30b9\u30c6\u30e0\u5727\u304c\u4e0a\u6607\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u3001Modeler\u3067 Dwell Volume (t<sub>R<\/sub> \u306e\u5f71\u97ff\u3092\u30b7\u30df\u30e5\u30ec\u30fc\u30c8\u3059\u308b\u305f\u3081)\u3092\u5897\u3084\u3057\u305f\u3068\u3057\u3066\u3082\u3001\u30b7\u30b9\u30c6\u30e0\u5727\u306e\u4e0a\u6607\u3092\u8a08\u7b97\u306b\u53cd\u6620\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30b7\u30b9\u30c6\u30e0\u5727\u304c\u3069\u306e\u7a0b\u5ea6\u4e0a\u6607\u3059\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u3001\u4ee5\u4e0b\u306e\u4f8b\u3092\u53c2\u8003\u306b\u5225\u9014\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">5 \u00b5m (50 x 2.1 \u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0): \u7d041500\u20132000 psi \u306e\u5897\u52a0<\/li>\n\n\n\n<li style=\"font-size:16px\">3 \u00b5m (50 x 2.1 \u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0): \u7d042000\u20133000 psi \u306e\u5897\u52a0<\/li>\n\n\n\n<li style=\"font-size:16px\">2 \u00b5m (50 x 2.1 \u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0): \u7d043500\u20134000 psi \u306e\u5897\u52a0<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-22\" style=\"font-size:20px\"><strong>\u79fb\u52d5\u76f8(Mobile Phase)<\/strong><\/h4>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-23\" style=\"font-size:19px\">\u6eb6\u5a92A(Eluent A), \u6eb6\u5a92B(Eluent B)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Pro <em>EZ<\/em>LC\u30e9\u30a4\u30d6\u30e9\u30ea\u306f\u3001Restek\u306e\u5316\u5b66\u8005\u306b\u3088\u3063\u3066\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u6700\u3082\u9069\u3057\u305f\u79fb\u52d5\u76f8\u3001\u6dfb\u52a0\u5264\u3001\u304a\u3088\u3073\u7de9\u885d\u6db2\u3092\u4f7f\u7528\u3057\u3066\u4f5c\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u3088\u3063\u3066\u3001\u7570\u306a\u308b\u6eb6\u5a92\u3001\u6dfb\u52a0\u5264\u3001\u307e\u305f\u306f\u7de9\u885d\u6db2\u304c\u5229\u7528\u53ef\u80fd\u306a\u5834\u5408\u304c\u3042\u308a\u3001\u305d\u306e\u5834\u5408\u306f\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30ea\u30b9\u30c8\u3067\u9078\u629e\u53ef\u80fd\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001Drugs of Abuse\uff08\u4e71\u7528\u85ac\u7269\uff09\u30e9\u30a4\u30d6\u30e9\u30ea\u3067\u306f\u3001\u6eb6\u5a92B\u3068\u3057\u3066<strong>\u30e1\u30bf\u30ce\u30fc\u30eb<\/strong>\u307e\u305f\u306f<strong>\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb<\/strong>\u306e\u3044\u305a\u308c\u304b\u3092\u9078\u629e\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u6eb6\u5a92\u306e\u9078\u629e\u304cLC\u5206\u96e2\u306b\u4e0e\u3048\u308b\u5f71\u97ff\u306b\u3064\u3044\u3066\u3001\u8a73\u3057\u304f\u306f\u6280\u8853\u8a18\u4e8b\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<a href=\"https:\/\/discover.restek.com\/articles\/gnar3308\/effect-of-organic-solvent-on-selectivity-in-lc-separations\">https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3308\/effect-of-organic-solvent-on-selectivity-in-lc-separations\uff08\u65e5\u672c\u8a9e\u8a18\u4e8b\u306f\u6e96\u5099\u4e2d\u3067\u3059\uff09<\/a><\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-24\" style=\"font-size:19px\">\u6e29\u5ea6(Temperature)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u8a31\u5bb9\u3055\u308c\u308b\u6e29\u5ea6\u7bc4\u56f2\u306f\u3001\u4f7f\u7528\u3059\u308b\u30e9\u30a4\u30d6\u30e9\u30ea\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001Drugs of Abuse\u30e9\u30a4\u30d6\u30e9\u30ea\u306e\u5834\u5408\u3001\u8a31\u5bb9\u6e29\u5ea6\u7bc4\u56f2\u306f30\u2103\uff5e60\u2103\u3067\u3059\u3002<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-25\" style=\"font-size:19px\">\u80cc\u5727(Back Pressure)<\/h5>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">Modeler\u304c\u8a08\u7b97\u3059\u308b\u80cc\u5727\u306f\u3001\u6d41\u91cf\u3068\u9078\u629e\u3057\u305f\u30ab\u30e9\u30e0\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u57fa\u3065\u3044\u3066\u63a8\u5b9a\u3055\u308c\u307e\u3059\u3002\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30e1\u30cb\u30e5\u30fc\u304b\u3089\u5727\u529b\u5358\u4f4d\u3092\u9078\u629e\u3057\u307e\u3059\u3002<strong>&nbsp;psi<\/strong>, <strong>kPa<\/strong>, <strong>bar<\/strong>, <strong>atm<\/strong>\u304b\u3089\u9078\u629e\u3067\u304d\u307e\u3059\u3002\u9078\u629e\u3057\u305f\u5727\u529b\u5358\u4f4d\u306f\u3001\u691c\u7d22\u4e2d\u3084Modeler\u4f7f\u7528\u4e2d\u306f\u7dad\u6301\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-theme-palette-5-color has-text-color has-link-color wp-elements-26 wp-block-paragraph\" style=\"font-size:18px\"><em><strong>\u30ab\u30e9\u30e0ID\u5225\u5b9f\u7528\u6d41\u91cf\u7bc4\u56f2\u00a0<\/strong><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">\u5185\u5f842.1 mm \u30ab\u30e9\u30e0: 0.4\u20130.6 mL\/min&nbsp;<\/li>\n\n\n\n<li style=\"font-size:16px\">\u5185\u5f843.0 mm \u30ab\u30e9\u30e0: 0.7\u20131.0 mL\/min&nbsp;<\/li>\n\n\n\n<li style=\"font-size:16px\">\u5185\u5f844.6 mm \u30ab\u30e9\u30e0: 1.4\u20131.6 mL\/min&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"has-theme-palette-5-color has-text-color has-link-color wp-elements-27 wp-block-paragraph\" style=\"font-size:18px\"><em><strong>\u30b7\u30b9\u30c6\u30e0\u306e\u4e00\u822c\u7684\u306a\u5727\u529b\u5236\u9650\u00a0<\/strong><\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:16px\">UHPLC: 15,000 psi (~1000 bar)<\/li>\n\n\n\n<li style=\"font-size:16px\">\u6e96UHPLC: 8700 psi (~600 bar)<\/li>\n\n\n\n<li style=\"font-size:16px\">HPLC: 5800 psi (~400 bar)<\/li>\n<\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji7\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-28\" style=\"font-size:22px\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6(Gradient Program)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u306f\u3001\u3053\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u5909\u66f4\u3001\u8ffd\u52a0\u3001\u524a\u9664\u3067\u304d\u307e\u3059\u3002\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u8ffd\u52a0\u3059\u308b\u306b\u306f\u3001<strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30b9\u30c6\u30c3\u30d7\u6570(# of Gradient Steps)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u306e\u5024\u30921\u301c3\u306e\u5024\u306b\u5909\u66f4\u3057\u307e\u3059\u3002Modeler\u306f\u3001\u5143\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u7dad\u6301\u3059\u308b\u5024\u3092\u5272\u308a\u5f53\u3066\u306a\u304c\u3089\u3001\u65b0\u3057\u3044\u30b9\u30c6\u30c3\u30d7\u3092\u81ea\u52d5\u7684\u306b\u633f\u5165\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30b9\u30c6\u30c3\u30d7\u3092\u8abf\u6574\u3057\u3066\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30b9\u30c6\u30c3\u30d7\u306b\u52a0\u3048\u3066\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u958b\u59cb\u70b9\u3068\u7d42\u4e86\u70b9\u306b\u30db\u30fc\u30eb\u30c9\u6761\u4ef6\u3092\u8ffd\u52a0\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u6700\u5f8c\u306b\u518d\u5e73\u8861\u306e\u6761\u4ef6\u3092\u8ffd\u52a0\u3057\u3066\u3001\u6b21\u306e\u5206\u6790\u306e\u305f\u3081\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u518d\u5e73\u8861\u5316\u3092\u884c\u3046\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u307b\u3068\u3093\u3069\u306e\u5834\u5408\u30011\uff5e3\u30b9\u30c6\u30c3\u30d7\u306e\u5358\u7d14\u306a\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u3001\u8a31\u5bb9\u3067\u304d\u308b\u5206\u96e2\u5ea6\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3088\u308a\u591a\u304f\u306e\u30b9\u30c6\u30c3\u30d7\u3092\u6301\u3064\u8907\u96d1\u306a\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u304c\u5fc5\u8981\u306a\u5834\u5408\u306f\u3001\u30db\u30fc\u30eb\u30c9\u3068\u518d\u5e73\u8861\u5316\u30d5\u30a3\u30fc\u30eb\u30c9\u3092\u4f7f\u7528\u3057\u3066\u3001\u6700\u59276\u30b9\u30c6\u30c3\u30d7\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306b\u76f8\u5f53\u3059\u308b\u5206\u96e2\u6761\u4ef6\u3092\u4f5c\u6210\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30db\u30fc\u30eb\u30c9\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30b9\u30c6\u30c3\u30d7\u3001\u304a\u3088\u3073\u518d\u5e73\u8861\u5316\u3092\u3059\u3079\u3066\u542b\u3081\u3066\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u30fb\u30b9\u30c6\u30c3\u30d7\u306e\u6700\u5927\u6570\u306f\uff16\u3067\u3042\u308b\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-29\" style=\"font-size:20px\"><strong>\u521d\u671f\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0(Add Start Isocratic Hold)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u6700\u521d\u306e\u521d\u671f\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u306f\u3001<strong>\u521d\u671f\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0<\/strong>\u30dc\u30c3\u30af\u30b9\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u306b\u8ffd\u52a0\u3055\u308c\u307e\u3059\u3002\u30d7\u30ed\u30b0\u30e9\u30e0\u306f\u81ea\u52d5\u7684\u306b1\u5206\u9593\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0\u3057\u307e\u3059\u304c\u3001\u305d\u306e\u5f8c\u6761\u4ef6\u306e\u8abf\u6574\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-30\" style=\"font-size:20px\"><strong>\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0(Add Final Isocratic Hold)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5206\u6790\u306e\u6700\u5f8c\u306b\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0\u3059\u308b\u306b\u306f\u3001<strong>\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0<\/strong>\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u81ea\u52d5\u7684\u306b1\u5206\u9593\u306e\u30db\u30fc\u30eb\u30c9\u304c\u8ffd\u52a0\u3055\u308c\u307e\u3059\u304c\u3001\u305d\u306e\u5f8c\u6761\u4ef6\u306e\u8abf\u6574\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<pre class=\"wp-block-preformatted has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color wp-elements-31\" style=\"font-size:16px\"><em><strong>\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u3063\u3066\u306f\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3059\u308b\u305f\u3081\u306b\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u304c\u5fc5\u8981\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u5834\u5408\u3001Modeler\u306f\u81ea\u52d5\u7684\u306b\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u3092\u8ffd\u52a0\u3057\u3001\u6700\u7d42\u6761\u4ef6\u306e\u30db\u30fc\u30eb\u30c9\u306b\u306f\u5fc5\u8981\u306a\u6700\u5c0f\u5024\u304c\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002<\/strong><\/em><\/pre>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-32\" style=\"font-size:20px\"><strong>\u518d\u5e73\u8861\u5316\u6642\u9593\u3092\u8ffd\u52a0(Add Re-Equilibration Time)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u518d\u5e73\u8861\u5316\u6642\u9593\u3092\u8ffd\u52a0(Add Re-Equilibration Time)<\/strong> \u30dc\u30c3\u30af\u30b9\u306f\u3001\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u6700\u521d\u306e%B\u5024\u306b\u623b\u3059\u30b9\u30c6\u30c3\u30d7\u3092\u8ffd\u52a0\u3057\u307e\u3059\u3002<em>\u30c7\u30d5\u30a9\u30eb\u30c8\u306e\u30ab\u30e9\u30e0\u6d17\u6d44\u56de\u6570\u306f10\u500d\u91cf\u3068\u306a\u3063\u3066\u304a\u308a\u3001\u6761\u4ef6\u3067\u8a2d\u5b9a\u3055\u308c\u305f\u6d41\u901f\u306b\u57fa\u3065\u3044\u3066\u3001\u30ab\u30e9\u30e0\u5185\u5bb9\u91cf\u306e10\u500d\u3067\u6d17\u6d44\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u6642\u9593\u304c\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002<\/em>&nbsp;<strong>\u500d\u91cf\u30ab\u30e9\u30e0\u5185\u5bb9\u7a4d\u3067\u6d17\u6d44(# of Column Rinses)<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u3092\u8abf\u6574\u3059\u308b\u3068\u3001\u3053\u306e\u518d\u5e73\u8861\u5316\u30b9\u30c6\u30c3\u30d7\u306b\u5fc5\u8981\u306a\u6642\u9593\u304c\u81ea\u52d5\u7684\u306b\u8abf\u6574\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<pre class=\"wp-block-preformatted has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color wp-elements-33\" style=\"font-size:16px\"><em><strong>\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u8a31\u5bb9\u3059\u308b\u30ab\u30e9\u30e0\u6d17\u6d44\u306e\u6700\u5c0f\u56de\u6570\u306f\u6c7a\u307e\u3063\u3066\u3044\u307e\u3059\u3002\u30ab\u30e9\u30e0\u5185\u5bb9\u91cf\u306b\u52a0\u3048\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u5b8c\u5168\u306b\u5143\u306e\u79fb\u52d5\u76f8\u7d44\u6210\u306b\u623b\u3059\u305f\u3081\u306b\u5fc5\u8981\u306a\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u3082\u8003\u616e\u3055\u308c\u307e\u3059\u3002<\/strong><\/em><\/pre>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji8\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-34\" style=\"font-size:22px\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316(Optimize Gradient Slope)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">30<strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316<\/strong>\u30dc\u30bf\u30f3\u306f\u3001\u7279\u5b9a\u306e\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u30e2\u30c7\u30eb\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u7c21\u5358\u306b\u8abf\u6574\u3059\u308b\u305f\u3081\u306e\u6a5f\u80fd\u3067\u3059\u3002\u3053\u306e\u30dc\u30bf\u30f3\u3092\u4f7f\u3046\u3068\u3001\u3055\u307e\u3056\u307e\u306a%B\u6761\u4ef6\u3092\u691c\u8a0e\u3057\u3001\u524d\u56de\u306e\u5206\u6790\u6642\u9593\u3068\u5206\u96e2\u3055\u308c\u305f\u5316\u5408\u7269\u6570\u3092\u6e80\u305f\u3059\u304b\u3001\u3088\u308a\u826f\u3044\u30e2\u30c7\u30eb\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 \u3055\u3089\u306b\u6539\u826f\u304c\u53ef\u80fd\u306a\u5834\u5408\u306f\u3001\u30dc\u30bf\u30f3\u306e\u6a2a\u306b\u5186\u5f62\u306e\u77e2\u5370\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u4ee5\u4e0a\u306e\u6539\u826f\u304c\u4e0d\u53ef\u80fd\u306a\u5834\u5408\u3001\u30dc\u30bf\u30f3\u306f\u7121\u52b9\u306b\u306a\u308a\u307e\u3059\u3002\u5909\u66f4\u306f\u3001\u7d50\u679c\u30bb\u30af\u30b7\u30e7\u30f3\u306e<strong>\u5143\u306b\u623b\u3059(Undo)<\/strong>\u30dc\u30bf\u30f3\uff08\u307e\u305f\u306fCtrl-Z\u30ad\u30fc\uff09\u3067\u53d6\u308a\u6d88\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3068\u3066\u3082\u308f\u305a\u304b\u306a\uff08\u4f8b\u3048\u30701\uff05\u306e\uff09\uff05B\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316\u3067\u3082\u3001\u7d50\u679c\u3068\u3057\u3066\u5927\u304d\u306a\u5909\u5316\u3092\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-35\" style=\"font-size:20px\"><strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6(Target Resolution)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6<\/strong>\u30d5\u30a3\u30fc\u30eb\u30c9\u306e\u30c7\u30d5\u30a9\u30eb\u30c8\u306f\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u304c\u53ef\u80fd\u306a1.5\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u5206\u96e2\u3088\u308a\u4f4e\u3044\u5206\u96e2\u5ea6\u304c\u8a31\u5bb9\u3067\u304d\u308b\u5834\u5408\u306f\u3001\u3053\u3053\u3067\u5909\u66f4\u3067\u304d\u307e\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u306e\u6700\u5c0f\u5024\u304c\u30e9\u30dc\u306e\u5206\u6790\u8981\u4ef6\u307e\u305f\u306f\u54c1\u8cea\u8981\u4ef6\u306b\u9069\u5408\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u5e38\u306b\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u3053\u306e\u5024\u3092\u4e0a\u3052\u308b\u3068\u5206\u6790\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u3001\u4e0b\u3052\u308b\u3068\u5206\u6790\u6642\u9593\u304c\u77ed\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\uff08\u5927\u5e45\u306b\u77ed\u304f\u306a\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\uff09\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"background-color:#f29946\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"63\" height=\"56\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/icon-warning.gif\" alt=\"\" class=\"wp-image-28251\" title=\"-\"><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:85%\">\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-36 wp-block-paragraph\" style=\"font-size:16px\"><strong>\u8b66\u544a\uff01\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3092\u6700\u9069\u5316\u3059\u308b\u969b\u3001Pro <em>EZ<\/em>LC Modeler\u306f\u5168\u4f53\u306e\u5206\u6790\u6642\u9593\u3092\u3067\u304d\u308b\u9650\u308a\u77ed\u7e2e\u3059\u308b\u3088\u3046\u306b\u30d7\u30ed\u30b0\u30e9\u30e0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u65e2\u306b\u5206\u96e2\u3055\u308c\u305f\u5316\u5408\u7269\u3092\u7dad\u6301\u3057\u306a\u304c\u3089\u5206\u6790\u6642\u9593\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306b\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u3092\u6e80\u305f\u3057\u3066\u3044\u306a\u3044\u5316\u5408\u7269\u304c\u72a0\u7272\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u9069\u5316\u5f8c\u306b\u3059\u3079\u3066\u306e\u5bfe\u8c61\u5316\u5408\u7269\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u306b\u9054\u3057\u306a\u304b\u3063\u305f\u5834\u5408\u306f\u3001\u521d\u671f\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u306b\u623b\u3057\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u3092\u4e0b\u3052\u3066\u518d\u8a66\u884c\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u7279\u5b9a\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u3092\u7dad\u6301\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u305d\u308c\u3089\u306e\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u306b\u5408\u308f\u305b\u305f\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u306b\u8a2d\u5b9a\u3057\u3066\u304b\u3089\u6700\u9069\u5316\u3092\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"452\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-gnot3918-10a.gif\" alt=\"\" class=\"wp-image-22575\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center has-theme-palette-2-color has-text-color has-link-color wp-elements-37 wp-block-paragraph\" style=\"font-size:18px\"><em>\u4e0a\u8a18\u306e\u30d4\u30fc\u30af160\u3068165\u306e\u5206\u96e2\u5ea6\u3092\u7dad\u6301\u3059\u308b\u306b\u306f\u3001\u6700\u9069\u5316\u306e\u524d\u306b\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6\u30920.60\u306b\u5909\u66f4\u3057\u307e\u3059\u3002<\/em><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-38\" style=\"font-size:20px\"><strong>\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u6761\u4ef6(Isocratic Program)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u7279\u5b9a\u306e\u30e9\u30a4\u30d6\u30e9\u30ea(\u4f8b:\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9)\u3067\u306f\u3001\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u6761\u4ef6\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u304c\u5229\u7528\u53ef\u80fd\u3067\u3059\u3002 \u3053\u306e\u5834\u5408\u3082\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u30d1\u30e9\u30e1\u30fc\u30bf\u8abf\u6574\u3092\u884c\u3044\u307e\u3059\u304c\u3001\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u6761\u4ef6\u3067\u5909\u66f4\u53ef\u80fd\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u306f\u3001\u6d41\u91cf\u3068%B\u306e\u307f\u3068\u306a\u308a\u3001\u305d\u308c\u305e\u308c\u8a2d\u5b9a\u53ef\u80fd\u306a\u7bc4\u56f2\u5185\u3067\u306e\u307f\u5909\u66f4\u304c\u53ef\u80fd\u3067\u3059\u3002 \u7dcf\u5206\u6790\u6642\u9593\u306f\u3001\u6700\u5f8c\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306eRt\u3092\u30d9\u30fc\u30b9\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u5bb9\u91cf\u306e\u6b8b\u91cf\u5206\u3068\u3057\u3066\u7d041\u5206\u304c\u8ffd\u52a0\u3055\u308c\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-39\" style=\"font-size:20px\"><strong>\u7d50\u679c(Results)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u3067\u884c\u3063\u305f\u5909\u66f4\u3092\u5143\u306b\u623b\u3059\u306b\u306f\u3001\u7d50\u679c\u30bb\u30af\u30b7\u30e7\u30f3\u306e\u5143\u306b\u623b\u3059(Undo)\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u304b\u3001\u30ad\u30fc\u30dc\u30fc\u30c9\u306eCtrl-Z\u3092\u62bc\u3057\u307e\u3059\u3002\u5909\u66f4\u3092\u3084\u308a\u76f4\u3059\u306b\u306f\u3001\u3084\u308a\u76f4\u3057(Redo)\u30dc\u30bf\u30f3\u3092\u62bc\u3059\u304b\u3001\u30ad\u30fc\u30dc\u30fc\u30c9\u306e Ctrl-Y \u3092\u62bc\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<pre class=\"wp-block-preformatted has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color wp-elements-40\" style=\"font-size:16px\"><em><strong>\u5316\u5408\u7269\u30bf\u30d6\u3067\u300c\u30e2\u30c7\u30eb\u751f\u6210\u300d\u3092\u518d\u5b9f\u884c\u3059\u308b\u3068\u3001\u5206\u6790\u6761\u4ef6\u30bf\u30d6\u304c\u30ea\u30bb\u30c3\u30c8\u3055\u308c\u3001\u3059\u3079\u3066\u306e\u5909\u66f4\u5185\u5bb9\u304c\u30af\u30ea\u30a2\u3055\u308c\u307e\u3059\u3002<\/strong><\/em><\/pre>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-41\" style=\"font-size:20px\"><strong>Gradient Time + Delay\/Run Time<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u300cGradient Time + Delay\u300d\u306f\u3001\u30d7\u30ed\u30b0\u30e9\u30e0\u3055\u308c\u305f\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u304c\u30ab\u30e9\u30e0\u672b\u7aef\u306b\u5230\u9054\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u5408\u8a08\u6642\u9593\u3067\u3059\u3002\u30ab\u30e9\u30e0\u5bb9\u91cf\u3001\u30ab\u30e9\u30e0\u5916\u5bb9\u91cf\u3001\u304a\u3088\u3073\u6d41\u91cf\u304c\u8003\u616e\u3055\u308c\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u300cGradient Time + Delay\u300d\u306fModeler\u304c\u63d0\u4f9b\u3057\u305f\u79fb\u52d5\u76f8\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6642\u9593\u3088\u308a\u3082\u9577\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u79fb\u52d5\u76f8\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6642\u9593\u306b\u52a0\u3048\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306b\u79fb\u52d5\u76f8\u306e\u6700\u7d42\u6761\u4ef6\u304c\u5230\u9054\u3059\u308b\u307e\u3067\u306e\u6642\u9593\u304c\u8ffd\u52a0\u3055\u308c\u308b\u305f\u3081\u3067\u3059\u3002\u7279\u5b9a\u306e\u5316\u5408\u7269\u306e\u6eb6\u51fa\u6642\u306e\u79fb\u52d5\u76f8\u7d44\u6210\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3001\u63d0\u4f9b\u3055\u308c\u3066\u3044\u308b\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u30c6\u30fc\u30d6\u30eb\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u300cExit %B\u300d\u5217\u306b\u306f\u3001\u305d\u306e\u5316\u5408\u7269\u304c\u6eb6\u51fa\u3057\u305f\u6642\u70b9\u306e\u30ab\u30e9\u30e0\u5185\u306e\u5b9f\u969b\u306e\u79fb\u52d5\u76f8\u6761\u4ef6\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u300cRun Time\u300d \u306f\u3001\u300cGradient Time + Delay\u300d\u306b\u3001\u30db\u30fc\u30eb\u30c9\u6642\u9593\u3084\u30ab\u30e9\u30e0\u6d17\u6d44\u306a\u3069\u3001\u79fb\u52d5\u76f8\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u8ffd\u52a0\u3055\u308c\u305f\u3059\u3079\u3066\u306e\u30b9\u30c6\u30c3\u30d7\u306e\u6642\u9593\u304c\u52a0\u7b97\u3055\u308c\u307e\u3059\u3002\u4e0a\u8a18\u306e\u7406\u7531\u306b\u3088\u308a\u3001\u5b9f\u969b\u306e\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u306b\u8868\u793a\u3055\u308c\u308b\u6642\u9593\u3068\u6b63\u78ba\u306b\u4e00\u81f4\u3057\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-42\" style=\"font-size:20px\"><strong>\u30dc\u30a4\u30c9\u30bf\u30a4\u30e0 (T0)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30dc\u30a4\u30c9\u30bf\u30a4\u30e0\uff08T0\uff09\u306f\u3001\u4fdd\u6301\u3055\u308c\u306a\u3044\u5316\u5408\u7269\u304c\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u304b\u3089\u30ab\u30e9\u30e0\u3092\u7d4c\u3066\u691c\u51fa\u5668\u307e\u3067\u79fb\u52d5\u3059\u308b\u306e\u306b\u304b\u304b\u308b\u6642\u9593\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-43\" style=\"font-size:20px\"><strong>\u5206\u96e2\u3057\u305f\u540c\u91cd\u4f53\u5316\u5408\u7269(Isobaric Compounds Separated)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>\u5206\u96e2\u3057\u305f\u540c\u91cd\u4f53\u5316\u5408\u7269<\/strong>\u306e\u5024\u306f\u3001\u5bfe\u8c61\u5316\u5408\u7269\u306e\u3046\u3061\u3001<strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6<\/strong>\u3092\u9054\u6210\u3057\u305f\u5316\u5408\u7269\u306e\u6570\u3092\u793a\u3057\u307e\u3059\uff08\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f<strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u306e\u6700\u9069\u5316<\/strong>\u306e<strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u96e2\u5ea6<\/strong>\u3092\u53c2\u7167\u304f\u3060\u3055\u3044\uff09\u3002\u3053\u306e\u5024\u306f\u5b9f\u969b\u306e\u5206\u96e2\u3055\u308c\u305f\u5316\u5408\u7269\u306e\u7dcf\u6570<em>\u3067\u306f\u306a\u304f<\/em>\u3001\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u6570\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-44\" style=\"font-size:20px\"><strong>Critical Pair<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5206\u6790\u5168\u4f53\u306e\u4e2d\u3067\u6700\u3082\u5206\u96e2\u5ea6\u306e\u4f4e\u3044\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u756a\u53f7\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-3-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-45\" style=\"font-size:20px\"><strong>Critical Pair\u306e\u5206\u96e2\u5ea6(Critical Pair Resolution)<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u5206\u6790\u5168\u4f53\u3067\u6700\u3082\u5206\u96e2\u5ea6\u306e\u4f4e\u3044\u540c\u91cd\u4f53\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji9\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-46\" style=\"font-size:22px\">\u5316\u5408\u7269\u306e\u69cb\u9020\u3068\u7269\u6027\u30d3\u30e5\u30fc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u7279\u5b9a\u306e\u5316\u5408\u7269\u306e\u8a73\u7d30\u60c5\u5831\u3092\u8868\u793a\u3059\u308b\u306b\u306f\u3001\u30e2\u30c7\u30eb\u30d3\u30e5\u30fc\u5185\u306e\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u306e\u5316\u5408\u7269\u540d\u306e\u6a2a\u306b\u3042\u308b\u866b\u773c\u93e1\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002\u8868\u793a\u3055\u308c\u308b\u30dd\u30c3\u30d7\u30a2\u30c3\u30d7\u306b\u306f\u3001\u5316\u5408\u7269\u306e\u8a73\u7d30\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji10\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-47\" style=\"font-size:22px\">My <em>EZ<\/em>LC\u30bf\u30d6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\"><strong>My <em>EZ<\/em>LC<\/strong>\u30bf\u30d6\u306b\u306f\u4fdd\u5b58\u3055\u308c\u305f\u30e2\u30c7\u30eb\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading has-theme-palette-4-color has-theme-palette-7-background-color has-text-color has-background has-link-color wp-elements-48\" style=\"font-size:20px\"><strong>\u30e2\u30c7\u30eb\u306e\u4fdd\u5b58<\/strong><\/h4>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30e2\u30c7\u30eb\u3092\u4fdd\u5b58\u3059\u308b\u306b\u306f\u3001\u6b21\u306e\u3088\u3046\u306b\u3057\u307e\u3059\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li style=\"font-size:18px\">\u30e2\u30c7\u30eb\u5316\u3055\u308c\u305f\u7d50\u679c\u306e\u4e00\u756a\u4e0a\u306b\u3042\u308b<strong>\u7121\u984c&nbsp; \u30af\u30ea\u30c3\u30af\u3057\u3066\u7de8\u96c6(Untitled. Click here to edit.)<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u30bf\u30a4\u30c8\u30eb\u3092\u4ed8\u3051\u307e\u3059\u3002\u30bf\u30a4\u30c8\u30eb\u306e\u30c6\u30ad\u30b9\u30c8\u30dc\u30c3\u30af\u30b9\u30d5\u30a3\u30fc\u30eb\u30c9\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30bf\u30a4\u30c8\u30eb\u3092\u5165\u529b\u3057\u3001<strong>OK<\/strong>\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u304b\u30ad\u30fc\u30dc\u30fc\u30c9\u306eEnter\u30ad\u30fc\u3092\u62bc\u3057\u3066\u3001\u65b0\u3057\u3044\u30bf\u30a4\u30c8\u30eb\u3092\u56fa\u5b9a\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li style=\"font-size:18px\">Pro <em>EZ<\/em>LC Chromatogram Modeler\u306e\u4e0a\u90e8\u30d0\u30fc\u306b\u3042\u308b<strong>\u4fdd\u5b58(Save)<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<pre class=\"wp-block-preformatted has-theme-palette-9-color has-theme-palette-1-background-color has-text-color has-background has-link-color wp-elements-49\" style=\"font-size:16px\"><em><strong>\u7121\u984c\u3067\u306e\u4fdd\u5b58\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u304a\u52e7\u3081\u3057\u307e\u305b\u3093\u3002\u30e2\u30c7\u30eb\u3092\u30ed\u30fc\u30c9\u3057\u305f\u5f8c\u3084\u4f55\u5ea6\u3082\u30a2\u30af\u30bb\u30b9\u3057\u305f\u5f8c\u3067\u3042\u3063\u3066\u3082\u3001\u30bf\u30a4\u30c8\u30eb\u3092\u8ffd\u52a0\u3057\u3001\u30e2\u30c7\u30eb\u3092\u518d\u4fdd\u5b58\u3059\u308b\u3053\u3068\u306f\u53ef\u80fd\u3067\u3059\u3002<\/strong><\/em><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30e2\u30c7\u30eb\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u3092\u4fdd\u5b58\u3059\u308b\u306b\u306f\u3001<strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u3067\u5909\u66f4\u3092\u52a0\u3048\u3001\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u30e2\u30c7\u30eb\u306e\u30bf\u30a4\u30c8\u30eb\u3092\u5909\u66f4\u3057\u3001<strong>\u540d\u524d\u3092\u3064\u3051\u3066\u4fdd\u5b58(<\/strong><strong>Save A Copy)<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002\u4fdd\u5b58\u3055\u308c\u305f\u30e2\u30c7\u30eb\u306eMy <em>EZ<\/em>LC\u30ea\u30b9\u30c8\u306b\u65b0\u3057\u3044\u30a8\u30f3\u30c8\u30ea\u30fc\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30e2\u30c7\u30eb\u3092\u6bd4\u8f03\u3059\u308b\u306b\u306f\u3001My <em>EZ<\/em>LC\u30ea\u30b9\u30c8\u306e\u30a8\u30f3\u30c8\u30ea\u30fc\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">My <em>EZ<\/em>LC\u30ea\u30b9\u30c8\u306e\u30e2\u30c7\u30eb\u306f\u3001<strong>\u4fdd\u5b58<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u518d\u4fdd\u5b58\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30e2\u30c7\u30eb\u3092\u524a\u9664\u3059\u308b\u306b\u306f\u3001\u30e2\u30c7\u30eb\u306e\u30ea\u30b9\u30c8\u306e\u53f3\u4e0a\u89d2\u306b\u3042\u308b\u300cX\u300d\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u30dd\u30c3\u30d7\u30a2\u30c3\u30d7\u8868\u793a\u3055\u308c\u308b\u78ba\u8a8d\u30a2\u30e9\u30fc\u30c8\u3067<strong>OK<\/strong>\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u4fdd\u5b58\u3057\u305f\u30e2\u30c7\u30eb\u306f<strong>\u5206\u6790\u6761\u4ef6<\/strong>\u30bf\u30d6\u3092\u4f7f\u7528\u3057\u3066\u3055\u3089\u306b\u6700\u9069\u5316\u3067\u304d\u307e\u3059\u304c\u3001\u305d\u306e\u5f8c\u306e\u4f5c\u696d\u30bb\u30c3\u30b7\u30e7\u30f3\u3067\u5316\u5408\u7269\u3092<strong>\u5316\u5408\u7269<\/strong>\u30bf\u30d6\u306b\u8ffd\u52a0\u3057\u305f\u308a<strong>\u5316\u5408\u7269(<\/strong>\u30bf\u30d6\u304b\u3089\u524a\u9664\u3057\u305f\u308a\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:75px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 id=\"mokuji11\" class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-50\" style=\"font-size:22px\">\u30e2\u30c7\u30eb\u306e\u5370\u5237<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:18px\">\u30c4\u30fc\u30eb\u30d0\u30fc\u306e\u5370\u5237\u30dc\u30bf\u30f3\u3092\u9078\u629e\u3059\u308b\u3068\u3001\u30d6\u30e9\u30a6\u30b6\u306e\u5370\u5237\u30c0\u30a4\u30a2\u30ed\u30b0\u304c\u8868\u793a\u3055\u308c\u3001\u30e2\u30c7\u30eb\u3092\u5370\u5237\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u30da\u30fc\u30b8\u306e\u30c8\u30c3\u30d7\u3078\u623b\u308b<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u304c\u63d0\u4f9b\u3059\u308bChromatogram Modeler\u306f\u7121\u6599\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u30c4\u30fc\u30eb\u3067\u3059\u3002\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08LC\uff09\u306b\u7279\u5316\u3057\u3066\u30e2\u30c7\u30eb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4f5c\u6210\u3059\u308bPro EZLC\u306e\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u3068\u5165\u529b\u9805\u76ee\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2373],"resource-technique":[],"ppma_author":[414],"class_list":["post-45327","post","type-post","status-publish","format-standard","hentry","category-articles-ja","product-library-liquid-chromatography-products"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2373,"label":"Liquid Chromatography Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45327"}],"version-history":[{"count":25,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45327\/revisions"}],"predecessor-version":[{"id":100750,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45327\/revisions\/100750"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45327"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45327"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45327"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45327"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45327"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45327"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}