{"id":45329,"date":"2022-09-06T00:00:00","date_gmt":"2022-09-06T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysis-of-furan-and-alkylfurans-in-food-commodities-by-spme-arrow-gc-ms-japan\/"},"modified":"2026-01-14T16:55:58","modified_gmt":"2026-01-14T16:55:58","slug":"analysis-of-furan-and-alkylfurans-in-food-commodities-by-spme-arrow-gc-ms-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/fsan3916-ja\/analysis-of-furan-and-alkylfurans-in-food-commodities-by-spme-arrow-gc-ms-japan","title":{"rendered":"SPME Arrow GC-MS\u306b\u3088\u308b\u98df\u54c1\u4e2d\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306bSPME Arrow\u3068PAL CTC\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u3001\u5206\u6790\u30ab\u30e9\u30e0\u306bRxi-624Sil MS\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u3001\u4e73\u5150\u7528\u8abf\u5408\u4e73\uff08\u4ee5\u964d\u3001\u7c89\u30df\u30eb\u30af\uff09\u3068\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30d5\u30e9\u30f3\u3068\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306eGC-MS\u6700\u9069\u5316\u6761\u4ef6\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u5b9f\u9a13\u306e\u7d50\u679c\u3001\u9ad8\u6fc3\u5ea6\u3068\u4f4e\u6fc3\u5ea6\u306e\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u3092\u542b\u3080\u591a\u69d8\u306a\u30b5\u30f3\u30d7\u30eb\u30bf\u30a4\u30d7\u306b\u306f\u3001SPME Arrow\u3092\u7528\u3044\u305f\u524d\u51e6\u7406\u304c\u9069\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u306e\u307f\u3001\u307e\u305f\u306fSPME\u3068HS\u306e\u4f75\u7528\u3068\u6bd4\u8f03\u3057\u3066\u3001SPME Arrow\u306e\u307f\u3092\u524d\u51e6\u7406\u306b\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u98df\u54c1\u5b89\u5168\u691c\u67fb\u30e9\u30dc\u306e\u751f\u7523\u6027\u5411\u4e0a\u304c\u671f\u5f85\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u6f5c\u5728\u7684\u306a\u5065\u5eb7\u30ea\u30b9\u30af\u306b\u5bfe\u3059\u308b\u8a8d\u8b58\u306e\u9ad8\u307e\u308a\u306b\u3088\u308a\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306e\u5206\u6790\u306b\u5bfe\u3059\u308b\u9700\u8981\u3082\u5897\u52a0\u3057\u3066\u3044\u307e\u3059\u3002\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306f\u3001\u7119\u714e\u3084\u6bba\u83cc\u306a\u3069\u306e\u52a0\u71b1\u5de5\u7a0b\u3067\u8d77\u3053\u308b\u5316\u5b66\u53cd\u5fdc\u306b\u3088\u3063\u3066\u751f\u6210\u3055\u308c\u308b\u305f\u3081\u3001\u69d8\u3005\u306a\u98df\u54c1\u3092\u901a\u3058\u3066\u66dd\u9732\u306e\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u66dd\u9732\u306b\u3088\u308b\u5f71\u97ff\u304c\u307e\u3060\u5341\u5206\u306b\u5206\u304b\u3063\u3066\u3044\u306a\u3044\u305f\u3081\u3001\u6b27\u5dde\u59d4\u54e1\u4f1a\u306f2022\u5e74\u521d\u3081\u3001\u52a0\u76df\u56fd\u306b\u5bfe\u3057\u3001\u7279\u5b9a\u306e\u98df\u54c1\u306b\u542b\u307e\u308c\u308b\u30d5\u30e9\u30f3\u30012-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u30013-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3088\u3046\u6c42\u3081\u308b\u52e7\u544a\u3092\u63a1\u629e\u3057\u307e\u3057\u305f[1]\u3002\u307e\u305f\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u30012-\u30da\u30f3\u30c1\u30eb\u30d5\u30e9\u30f3\u30012-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\u306a\u3069\u306e\u975e\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u306b\u3064\u3044\u3066\u3082\u3001\u4fe1\u983c\u6027\u304c\u5b9f\u8a3c\u3055\u308c\u305f\u65b9\u6cd5\u304c\u3042\u308b\u5834\u5408\u3001\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306f\u63ee\u767a\u6027\u5316\u5408\u7269\u3067\u3042\u308a\u3001\u9759\u7684\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\uff08HS\uff09\u304a\u3088\u3073\/\u307e\u305f\u306f\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa\uff08SPME\uff09\u3068GC-MS\u3068\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u5206\u6790\u3067\u304d\u307e\u3059\u3002\u9759\u7684\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9GC-MS\u306f\u901a\u5e38\u3001\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u3092\u9ad8\u6fc3\u5ea6\u3067\u542b\u3080\u30b3\u30fc\u30d2\u30fc\u306a\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4f4e\u6fc3\u5ea6\u306e\u30b5\u30f3\u30d7\u30eb\u3067\u306f\u5206\u6790\u306e\u611f\u5ea6\u304c\u5341\u5206\u3067\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001SPME\u306f\u9ad8\u611f\u5ea6\u306a\u5206\u6790\u304c\u53ef\u80fd\u3067\u3042\u308a\u3001\u4f4e\u6fc3\u5ea6\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5f93\u6765\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\u306f\u975e\u5e38\u306b\u8106\u304f\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u6c42\u3081\u3089\u308c\u308b\u30e9\u30dc\u3067\u306e\u4f7f\u7528\u306b\u306f\u8ab2\u984c\u304c\u6b8b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306a\u6280\u8853\u7684\u5236\u7d04\u306b\u3088\u308a\u3001\u98df\u54c1\u5b89\u5168\u691c\u67fb\u30e9\u30dc\u306f\u3001\u898f\u5236\u6a5f\u95a2\u304c\u6c42\u3081\u308b\u8981\u4ef6\u3092\u6e80\u305f\u3059\u52b9\u7387\u7684\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u69cb\u7bc9\u3059\u308b\u3053\u3068\u304c\u96e3\u3057\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30e9\u30dc\u306e\u73fe\u5834\u306b\u304a\u3044\u3066\u306f\u3001\u5e45\u5e83\u3044\u6fc3\u5ea6\u7bc4\u56f2\u306e\u6210\u5206\u3092\u9ad8\u611f\u5ea6\u304b\u3064\u8fc5\u901f\u306b\u5206\u6790\u3067\u304d\u3001\u9577\u671f\u9593\u5b89\u5b9a\u3057\u3066\u904b\u7528\u53ef\u80fd\u306a\u8010\u4e45\u6027\u3092\u5099\u3048\u305f\u3001\u30b3\u30b9\u30c8\u52b9\u7387\u306e\u9ad8\u3044\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0a\u306e\u3088\u3046\u306a\u8ab2\u984c\u89e3\u6c7a\u3092\u76ee\u7684\u3068\u3057\u3066\u3001SPME Arrow\u306e\u6027\u80fd\u8a55\u4fa1\u3092\u5b9f\u65bd\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1354\" target=\"_blank\" rel=\"noopener\">SPME Arrow<\/a>\u3092\u5358\u4e00\u306e\u524d\u51e6\u7406\u6cd5\u3068\u3057\u3066\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u5206\u6790\u306b\u4f7f\u7528\u53ef\u80fd\u304b\u691c\u8a0e\u3092\u884c\u3044\u307e\u3057\u305f\u3002SPME Arrow\u306f\u7b2c2\u4e16\u4ee3\u306eSPME\u30c7\u30d0\u30a4\u30b9\u3067\u3001\u7834\u640d\u3092\u9632\u3050\u305f\u3081\u306b\u30b7\u30fc\u30b9\u3068\u30a4\u30f3\u30ca\u30fc\u30ed\u30c3\u30c9\u3067\u6a5f\u68b0\u7684\u306b\u5f37\u5316\u3055\u308c\u3066\u304a\u308a\u3001\u8ca0\u8377\u5bb9\u91cf\u3092\u5897\u3084\u3059\u305f\u3081\u306b\u6db2\u76f8\u91cf\u3082\u591a\u304f\u306a\u3063\u3066\u3044\u307e\u3059\uff08<strong>Figure 1<\/strong>\uff09\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6280\u8853\u306e\u521d\u671f\u6bd4\u8f03\u306b\u57fa\u3065\u304d\u3001\u30b3\u30fc\u30d2\u30fc\u304a\u3088\u3073\u7c89\u30df\u30eb\u30af\u4e2d\u306e\u7279\u5b9a\u306e\u6fc3\u5ea6\u7bc4\u56f2\u306b\u308f\u305f\u3063\u3066\u3001\u30d5\u30e9\u30f3\u3068\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u5206\u6790\u306b\u6700\u9069\u306aSPME Arrow GC-MS\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:\u00a0<\/strong>SPME Arrow\u306f\u3001\u5f93\u6765\u306e\u30d5\u30a1\u30a4\u30d0\u30fc\u3088\u308a\u3082\u8ca0\u8377\u5bb9\u91cf\u304c\u5927\u304d\u304f\u3001\u7834\u640d\u3092\u9632\u3050\u305f\u3081\u306b\u91d1\u5c5e\u3067\u88ab\u8986\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>SPME Arrows<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-01a.jpg\" alt=\"figure-article-FSAN3916-01a.jpg\" title=\"-\"><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>SPME \u30d5\u30a1\u30a4\u30d0\u30fc<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"861\" height=\"554\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-01b.jpg\" alt=\"\" class=\"wp-image-20025\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-01b.jpg 861w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-01b-300x193.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-01b-768x494.jpg 768w\" sizes=\"auto, (max-width: 861px) 100vw, 861px\" \/><\/figure>\n<\/div>\n<\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6a19\u6e96\u6eb6\u6db2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\uff08\u4ee5\u964d\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\uff09\u306e\u5358\u54c1\u6a19\u6e96\u6eb6\u6db2\u306f\u3001\u305d\u308c\u305e\u308c\u304c1 mg\/mL\u3068\u306a\u308b\u3088\u3046\u3001\u30ac\u30e9\u30b9\u30b7\u30ea\u30f3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u7d14\u6a19\u6e96\u7269\u8cea\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u306b\u6dfb\u52a0\u3057\u3066\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u6b21\u306b\u3001\u305d\u308c\u3089\u3092\u7528\u3044\u3066\u3001\u5168\u6210\u5206\u3092\u542b\u3080100 ppm\u6df7\u5408\u30b9\u30c8\u30c3\u30af\u6eb6\u6db2\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306e100 ppm\u6df7\u5408\u30b9\u30c8\u30c3\u30af\u6eb6\u6db2\u3082\u540c\u69d8\u306b\u8abf\u6574\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u691c\u91cf\u7dda\u306e\u4f4e\u6fc3\u5ea6\u7bc4\u56f2\u3092\u30ab\u30d0\u30fc\u3059\u308b\u305f\u3081\u306b\u3001100 ppm\u6df7\u5408\u30b9\u30c8\u30c3\u30af\u6eb6\u6db2\u3092\u305d\u308c\u305e\u308c10 \u00b5L\u306850 \u00b5L\u3001LC-MS\u30b0\u30ec\u30fc\u30c9\u306e\u6c3410 mL\u306b\u6dfb\u52a0\u3057\u3066\u30010.1 \u00b5g\/mL\u30680.5 \u00b5g\/mL\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u30021 \u03bcg\/mL\u306e\u5185\u90e8\u6a19\u6e96\u6eb6\u6db2\u306f\u3001100 ppm\u6df7\u5408\u30b9\u30c8\u30c3\u30af\u6eb6\u6db2100 \u03bcL\u30929.9 mL\u306e\u8d85\u7d14\u6c34\u306b\u6dfb\u52a0\u3057\u3066\u8abf\u6574\u3057\u307e\u3057\u305f\u3002\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u9ad8\u6fc3\u5ea6\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u304c\u542b\u307e\u308c\u3066\u3044\u305f\u305f\u3081\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u304a\u3088\u3073\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\uff080.5\u300110\u300125 \u03bcg\/mL\uff09\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u5358\u54c1\u6a19\u6e96\u6eb6\u6db2\u3092\u8d85\u7d14\u6c34\u306b\u76f4\u63a5\u6dfb\u52a0\u3057\u306610 \u03bcg\/mL\u304a\u3088\u307325 \u03bcg\/mL\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002\u3053\u306e10 \u03bcg\/mL\u6eb6\u6db2500 \u03bcL\u3092\u8d85\u7d14\u6c34\u306710 mL\u306b\u5e0c\u91c8\u3059\u308b\u3053\u3068\u3067\u30010.5 \u03bcg\/mL\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7c89\u30df\u30eb\u30af\u3068\u30a4\u30f3\u30b9\u30bf\u30f3\u30c8\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u5730\u5143\u306e\u98df\u6599\u54c1\u5e97\u3067\u8cfc\u5165\u3057\u307e\u3057\u305f\u3002\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3001\u5f93\u6765\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3001SPME Arrow\u3092\u6bd4\u8f03\u3059\u308b\u4e88\u5099\u5b9f\u9a13\u3092\u884c\u3044\u3001\u5e83\u7bc4\u56f2\u306a\u6fc3\u5ea6\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306b\u9069\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u624b\u9806\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\u3002\u30c6\u30b9\u30c8\u3092\u884c\u3063\u305f\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u306f\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u5316\u5b66\u7684\u6027\u8cea\u3001\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593\u3068\u6e29\u5ea6\u3001\u62bd\u51fa\u6642\u9593\u306a\u3069\u304c\u542b\u307e\u308c\u307e\u3059[2,3,4]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u671f\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u5b9f\u9a13\u306e\u7d50\u679c\u306b\u57fa\u3065\u304d\u3001SPME Arrow\u304c\u6700\u9069\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3068\u3057\u3066\u9078\u629e\u3055\u308c\u3001\u305d\u306e\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u8a55\u4fa1\u5b9f\u9a13\u3067\u306f<strong>Table I<\/strong>\u306b\u793a\u3059\u6700\u9069\u5316\u6761\u4ef6\u3067\u4f7f\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u3068\u6821\u6b63\u7528\u6eb6\u6db2\u306f\u300120 mL \u30ac\u30e9\u30b9\u30d0\u30a4\u30a2\u30eb\u306e\u4e2d\u3067\u8abf\u88fd\u3057\u3001PAL CTC\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u306b\u7d44\u307f\u8fbc\u307e\u308c\u305f 120 \u00b5m\u30ef\u30a4\u30c9\u30ab\u30fc\u30dc\u30f3\u30ec\u30f3\u30b8\/PDMS Restek PAL SPME Arrow\uff08cat.# 27487\uff09\u3092\u4f7f\u7528\u3057\u3066\u3001\u81ea\u52d5\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9 SPME\u3067\u62bd\u51fa\u304a\u3088\u3073\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I: <\/strong>\u7c89\u30df\u30eb\u30af\u304a\u3088\u3073\u30b3\u30fc\u30d2\u30fc\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6761\u4ef6<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u30b5\u30f3\u30d7\u30eb<\/strong><\/td><td><strong>\u7c89\u30df\u30eb\u30af<\/strong><\/td><td><strong>\u30b3\u30fc\u30d2\u30fc<\/strong><\/td><\/tr><tr><td><strong>\u5bb9\u91cf<\/strong><\/td><td colspan=\"2\">0.5 g<\/td><\/tr><tr><td><strong>30%\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\u6dfb\u52a0\u91cf<\/strong><\/td><td>10 mL<\/td><td>5 mL<\/td><\/tr><tr><td><strong>\u5185\u90e8\u6a19\u6e96\u6eb6\u6db2\u306e\u6dfb\u52a0\u91cf<\/strong><\/td><td>50 \u00b5L (1 \u00b5g\/mL \u6eb6\u6db2)<\/td><td>40 \u00b5L (25 \u00b5g\/mL \u6eb6\u6db2)<\/td><\/tr><tr><td><strong>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u6642\u9593<\/strong><\/td><td colspan=\"2\">10 min<\/td><\/tr><tr><td><strong>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u304a\u3088\u3073\u62bd\u51fa\u6e29\u5ea6<\/strong><\/td><td colspan=\"2\">50 \u00b0C<\/td><\/tr><tr><td><strong>\u64b9\u62cc<\/strong><\/td><td colspan=\"2\">250 rpm<\/td><\/tr><tr><td><strong>HS-SPME\u62bd\u51fa\u6642\u9593<\/strong><\/td><td>10 min<\/td><td>1 min<\/td><\/tr><tr><td><strong>\u8131\u7740\u6e29\u5ea6<\/strong><\/td><td colspan=\"2\">280 \u00b0C<\/td><\/tr><tr><td><strong>\u8131\u7740\u6642\u9593<\/strong><\/td><td colspan=\"2\">1 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u691c\u91cf\u7dda<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">30%\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\u30672\u7a2e\u985e\u306e\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002\u7c89\u30df\u30eb\u30af\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u4f4e\u6fc3\u5ea6\u691c\u91cf\u7dda\u3092\u7528\u3044\u3001\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u9ad8\u6fc3\u5ea6\u691c\u91cf\u7dda\u3092\u7528\u3044\u3066\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u4f4e\u6fc3\u5ea6\u691c\u91cf\u7dda\u7528\u306b\u306f10 mL\u3001\u9ad8\u6fc3\u5ea6\u691c\u91cf\u7dda\u7528\u306b\u306f5 \uff4dL\u306e\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\u3092\u30d0\u30a4\u30a2\u30eb\u306b\u5145\u586b\u3057\u307e\u3057\u305f\u3002<strong>Table II<\/strong>\u306b\u793a\u3057\u305f\u7570\u306a\u308b\u5bb9\u91cf\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306e\u4f5c\u696d\u6a19\u6e96\u6eb6\u6db2\u3092\u52a0\u3048\u3066\u3001\u7570\u306a\u308b\u6fc3\u5ea6\u306e\u6821\u6b63\u7528\u30d0\u30a4\u30a2\u30eb\u3092\u6e96\u5099\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5404\u6821\u6b63\u7528\u30d0\u30a4\u30a2\u30eb\u306b\u5185\u90e8\u6a19\u6e96\u6eb6\u6db2\u3092\u6dfb\u52a0\u3057\u307e\u3057\u305f\uff08\u4f4e\u6fc3\u5ea6\u306e\u691c\u91cf\u7dda\u7528\u306b\u306f1 \u00b5g\/mL\u6eb6\u6db2\u309250 \u00b5L\u3001\u9ad8\u6fc3\u5ea6\u306e\u691c\u91cf\u7dda\u7528\u306b\u306f25 \u00b5g\/mL\u6eb6\u6db2\u309240 \u00b5L\uff09\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u9055\u3044\u306b\u3088\u308b\u56de\u53ce\u7387\u306e\u3070\u3089\u3064\u304d\u3092\u88dc\u6b63\u3059\u308b\u305f\u3081\u306b\u3001\u307b\u307c\u3059\u3079\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306b\u5bfe\u3057\u3066\u540c\u4f4d\u4f53\u6a19\u8b58\u5316\u5408\u7269\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u305f\u3060\u3057\u30012-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u30683-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u306b\u3064\u3044\u3066\u306f\u30012-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3-d6\u304c\u4e21\u65b9\u306e\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u9069\u7528\u53ef\u80fd\u3060\u3063\u305f\u305f\u3081\u3001\u305d\u308c\u305e\u308c\u5c02\u7528\u306e\u6a19\u8b58\u5316\u5408\u7269\u3092\u7528\u610f\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002 \u691c\u91cf\u7dda\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306e\u9762\u7a4d\/\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306e\u5e73\u5747\u9762\u7a4d\u6bd4\uff08n=2\uff09\u3092\u6dfb\u52a0\u6fc3\u5ea6\u306b\u5bfe\u3057\u3066\u30d7\u30ed\u30c3\u30c8\u3057\u3001\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II: <\/strong>\u6821\u6b63\u7528\u6eb6\u6db2<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\" rowspan=\"2\">&nbsp;<\/td><td colspan=\"2\"><strong>\u4f4e\u6fc3\u5ea6\u306e\u691c\u91cf\u7dda\u3000\u3000<br><\/strong><\/td><td colspan=\"2\"><strong>\u9ad8\u6fc3\u5ea6\u306e\u691c\u91cf\u7dda<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\"><strong>\u30d0\u30a4\u30a2\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206 ng<\/strong><\/td><td><strong>\u6dfb\u52a0\u3057\u305f\u4f5c\u696d\u6eb6\u6db2 \u03bcL\uff08\u6eb6\u6db2\u6fc3\u5ea6\uff09<\/strong><\/td><td><strong>\u30d0\u30a4\u30a2\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206 ng<\/strong><\/td><td><strong>\u3000\u6dfb\u52a0\u3057\u305f\u4f5c\u696d\u6eb6\u6db2 \u03bcL\uff08\u6eb6\u6db2\u6fc3\u5ea6\uff09<\/strong><\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 1<\/td><td>1.25<\/td><td>12.5 (0.1 \u00b5g\/mL)<\/td><td>25<\/td><td>50 (0.5 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 2<\/td><td>2.5<\/td><td>25 (0.1 \u00b5g\/mL)<\/td><td>50<\/td><td>100 (0.5 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 3<\/td><td>5<\/td><td>10 (0.5 \u00b5g\/mL)<\/td><td>100<\/td><td>10 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 4<\/td><td>10<\/td><td>20 (0.5 \u00b5g\/mL)<\/td><td>200<\/td><td>20 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 5<\/td><td>20<\/td><td>40 (0.5 \u00b5g\/mL)<\/td><td>500<\/td><td>50 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 6<\/td><td>50<\/td><td>100 (0.5 \u00b5g\/mL)<\/td><td>1000<\/td><td>100 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 7<\/td><td>100<\/td><td>200 (0.5 \u00b5g\/mL)<\/td><td>2000<\/td><td>200 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 8<\/td><td>150<\/td><td>300 (0.5 \u00b5g\/mL)<\/td><td>4000<\/td><td>400 (10 \u00b5g\/mL)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Level 9<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>8000<\/td><td>800 (10 \u00b5g\/mL)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u30e1\u30bd\u30c3\u30c9\u691c\u8a3c\u30b5\u30f3\u30d7\u30eb<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u6027\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3001AOAC [6]\u306e\u6a19\u6e96\u30e1\u30bd\u30c3\u30c9\u6027\u80fd\u8981\u4ef6\u306b\u57fa\u3065\u304d\u3001\u7c89\u30df\u30eb\u30af\u3068\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306b\u30012\u3064\u306e\u7570\u306a\u308b\u6fc3\u5ea6\u30ec\u30d9\u30eb\u3067\u3001\u65e2\u77e5\u91cf\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u3092\u6dfb\u52a0\u3057\u3066\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3057\u305f\u3002\uff08\u7c89\u30df\u30eb\u30af\u30b5\u30f3\u30d7\u30eb\u306f5 \u00b5g\/kg\u306850 \u00b5g\/kg\uff08n=3\uff09\u3067\u3001\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306f1000 \u00b5g\/kg\u30684000 \u00b5g\/kg\uff08n=3\uff09\u3067\u6dfb\u52a0\uff09\u3002\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306e\u307f\u3092\u6dfb\u52a0\u3057\u305f\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u306b\u95a2\u3057\u3066\u3082\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\uff08n=3\uff09\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u30e1\u30bd\u30c3\u30c9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306eGC-MS\u5206\u6790\u306f\u30015977B MSD\u3068\u7d44\u307f\u5408\u308f\u305b\u305fAgilent 7890B GC\u3067\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002GC-MS\u30e1\u30bd\u30c3\u30c9\u306e\u8a73\u7d30\u3092<strong>Table III<\/strong>\u304a\u3088\u3073<strong>Table IV<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002\u30ef\u30a4\u30c9\u30ab\u30fc\u30dc\u30f3\u30ec\u30f3\u30b8SPME Arrows\u3067\u9ad8\u6fc3\u5ea6\u306a\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u3092\u884c\u3046\u305f\u3081\u306b\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306b3\u3064\u306e\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u5909\u66f4\u3057\u307e\u3057\u305f\u3002GC \u30b9\u30d7\u30ea\u30c3\u30c8\u3092 100:1 (\u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u901f 140 mL\/min) \u306b\u8a2d\u5b9a\u3001\u62bd\u51fa\u6642\u9593\u3092 1 \u5206\u306b\u8a2d\u5b9a\u3001\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\u306e\u5bb9\u91cf\u30925 mL\u306b\u8abf\u6574\u3057\u307e\u3057\u305f\u3002SPME Arrow\u306b\u5bfe\u5fdc\u3059\u308b\u305f\u3081\u3001\u5185\u5f84\u304c\u5e83\u30441.8 mm\u306e\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> GC-MS\u88c5\u7f6e\u6761\u4ef6<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td>Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 \u00b5m (cat.# 13868)<\/td><\/tr><tr><td><strong>\u6ce8\u5165\u30e2\u30fc\u30c9<\/strong><\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\u3000 (\u7c89\u30df\u30eb\u30af\u306f10:1 \u30b3\u30fc\u30d2\u30fc\u306f 100:1)<\/td><\/tr><tr><td><strong>\u30e9\u30a4\u30ca\u30fc<\/strong><\/td><td>Topaz 1.8 mm ID SPME\/straight liner (cat.# 23280)<\/td><\/tr><tr><td><strong>\u6ce8\u5165\u6e29\u5ea6<\/strong><\/td><td>280 \u00b0C&nbsp;<\/td><\/tr><tr><td><strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u30d5\u30ed\u30fc<\/strong><\/td><td>\u00b7&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; \u7c89\u30df\u30eb\u30af: 14.0 mL\/min&nbsp;(10:1) \u00b7&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;\u30b3\u30fc\u30d2\u30fc: 140 mL\/min (100:1)<\/td><\/tr><tr><td><strong>\u30d1\u30fc\u30b8\u30d5\u30ed\u30fc<\/strong><\/td><td>5 mL\/min&nbsp;<\/td><\/tr><tr><td><strong>\u30aa\u30fc\u30d6\u30f3<\/strong><\/td><td>35 \u00b0C (hold 3 min) to 75 \u00b0C by 8 \u00b0C\/min, then to 200 \u00b0C by 25\u00b0C\/min (hold 1 min)<\/td><\/tr><tr><td><strong>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/strong><\/td><td>He, constant flow&nbsp;<\/td><\/tr><tr><td><strong>\u6d41\u901f<\/strong><\/td><td>1.40 mL\/min&nbsp;<\/td><\/tr><tr><td><strong>\u5206\u6790\u88c5\u7f6e<\/strong><\/td><td>MS (\u56db\u91cd\u6975)<\/td><\/tr><tr><td><strong>\u53d6\u5f97\u30bf\u30a4\u30d7<\/strong><\/td><td>SIM&nbsp;<\/td><\/tr><tr><td><strong>\u30a4\u30aa\u30f3\u5316\u30e2\u30fc\u30c9<\/strong><\/td><td>EI&nbsp;(70 eV)<\/td><\/tr><tr><td><strong>\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u6e29\u5ea6<\/strong><\/td><td>280 \u00b0C &nbsp;<\/td><\/tr><tr><td><strong>\u30bd\u30fc\u30b9\u6e29\u5ea6<\/strong><\/td><td>325 \u00b0C&nbsp;<\/td><\/tr><tr><td><strong>\u56db\u91cd\u6975\u6e29\u5ea6<\/strong><\/td><td>200 \u00b0C &nbsp;<\/td><\/tr><tr><td><strong>\u6eb6\u5a92\u30c7\u30a3\u30ec\u30a4<\/strong><\/td><td>2.2 min<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table IV: <\/strong>MS\u30d1\u30e9\u30e1\u30fc\u30bf\uff08SIM\u30e2\u30fc\u30c9\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u30bb\u30b0\u30e1\u30f3\u30c8 \u958b\u59cb\u6642\u9593\uff08\u5206\uff09<\/strong><\/td><td><strong>\u5316\u5408\u7269 (t<sub>R<\/sub>, min)<\/strong><\/td><td><strong>\u30a4\u30aa\u30f3<\/strong><\/td><td><strong>Dwell Time (ms)<\/strong><\/td><\/tr><tr><td rowspan=\"4\">2.2<\/td><td rowspan=\"2\">Furan (2.447)<\/td><td>39<\/td><td rowspan=\"4\">50<\/td><\/tr><tr><td>68*<\/td><\/tr><tr><td rowspan=\"2\">Furan-d4 (2.428)<\/td><td>42<\/td><\/tr><tr><td>72*<\/td><\/tr><tr><td rowspan=\"8\">4.2<\/td><td rowspan=\"3\">2-Methylfuran (4.536)<\/td><td>53<\/td><td rowspan=\"3\">30<\/td><\/tr><tr><td>81<\/td><\/tr><tr><td>82*<\/td><\/tr><tr><td rowspan=\"3\">3-Methylfuran (4.846)<\/td><td>53<\/td><td rowspan=\"3\">30<\/td><\/tr><tr><td>81<\/td><\/tr><tr><td>82*<\/td><\/tr><tr><td rowspan=\"2\">2-Methylfuran-d6 (4.464)<\/td><td>58<\/td><td rowspan=\"2\">30<\/td><\/tr><tr><td>88*<\/td><\/tr><tr><td rowspan=\"9\">6.6<\/td><td rowspan=\"3\">2-Ethylfuran (7.100)<\/td><td>53<\/td><td rowspan=\"3\">30<\/td><\/tr><tr><td>81*<\/td><\/tr><tr><td>96<\/td><\/tr><tr><td rowspan=\"2\">2-Ethylfuran-d5 (7.001)<\/td><td>55<\/td><td rowspan=\"2\">30<\/td><\/tr><tr><td>101*<\/td><\/tr><tr><td rowspan=\"2\">2,5-Dimethylfuran (7.243)<\/td><td>67<\/td><td rowspan=\"2\">30<\/td><\/tr><tr><td>95*<\/td><\/tr><tr><td rowspan=\"2\">2,5-Dimethylfuran-d3 (7.179)<\/td><td>84<\/td><td rowspan=\"2\">30<\/td><\/tr><tr><td>99*<\/td><\/tr><tr><td rowspan=\"4\">10.6<\/td><td rowspan=\"2\">2-Pentylfuran (11.570)<\/td><td>81<\/td><td>30<\/td><\/tr><tr><td>138*<\/td><td>30<\/td><\/tr><tr><td rowspan=\"2\">2-Pentylfuran-d11 (11.501)<\/td><td>83<\/td><td>30<\/td><\/tr><tr><td>149*<\/td><td>30<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u5b9a\u91cf\u30a4\u30aa\u30f3<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3001SPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3001SPME Arrow\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u6bd4\u8f03<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u306e\u521d\u671f\u6bb5\u968e\u3067\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u6226\u7565\u306e\u6bd4\u8f03\u3092\u884c\u3044\u307e\u3057\u305f\u3002SPME Arrow\uff08\u30ef\u30a4\u30c9\u30ab\u30fc\u30dc\u30f3\u30ec\u30f3\u30b8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\uff09\u3001\u5f93\u6765\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\uff08\u30ef\u30a4\u30c9\u30ab\u30fc\u30dc\u30f3\u30ec\u30f3\u30b8\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\uff09\u3001\u304a\u3088\u3073\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3092\u4f7f\u7528\u3057\u3066\u3001\u3059\u3079\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\uff08\u5404\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u520620 ng\uff09\u3092\u6dfb\u52a0\u3057\u305f30%\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\uff0810 mL\uff09\u304b\u3089\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3092\u884c\u3044\u3001\u89b3\u5bdf\u3055\u308c\u305f\u9762\u7a4d\u5024\u3067\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3057\u305f\u3002<strong>Figure 2<\/strong>\u306b\u793a\u3055\u308c\u308b\u3088\u3046\u306b\u3001SPME Arrow\u306f\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3084\u5f93\u6765\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001\u3059\u3079\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306b\u95a2\u3057\u3066\u6709\u610f\u306b\u9ad8\u3044\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001SPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001SPME Arrow\u306b\u306f\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u30b7\u30fc\u30b9\u3068\u5b89\u5b9a\u5316\u7528\u306e\u30a4\u30f3\u30ca\u30fc\u30ed\u30c3\u30c9\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u4f7f\u7528\u4e2d\u306e\u7834\u640d\u3092\u9632\u3050\u3068\u3044\u3046\u5229\u70b9\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u30ec\u30b9\u30dd\u30f3\u30b9\u30c7\u30fc\u30bf\u306e\u6709\u610f\u6027\u304a\u3088\u3073\u9811\u4e08\u306a\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u69cb\u9020\u306b\u57fa\u3065\u304d\u3001SPME Arrow\u306e\u307f\u3092\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3068\u3057\u3066\u63a1\u7528\u3057\u3001GC-MS\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2: <\/strong>SPME Arrow\u3092\u4f7f\u7528\u3057\u305f\u969b\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30ec\u30b9\u30dd\u30f3\u30b9\u306f\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u3084\u5f93\u6765\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3092\u4f7f\u7528\u3057\u305f\u969b\u3088\u308a\u3082\u6709\u610f\u306b\u9ad8\u304b\u3063\u305f<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-05.jpg\" alt=\"figure-article-FSAN3916-05.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u63ee\u767a\u6027\u6709\u6a5f\u7269\u306b\u5bfe\u3059\u308b\u9078\u629e\u6027\u304c\u9ad8\u304f\u3001SPME \u6cd5\u3068\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\u306e\u4e21\u65b9\u306b\u9069\u3057\u3066\u3044\u308b\u3053\u3068\u304b\u3089\u3001\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790\u306b\u306f\u3001Rxi-624Sil MS \u30ab\u30e9\u30e0\uff0830 m\u3001\u5185\u5f84 0.25mm\u30011.40 \u00b5m [cat.# 13868]\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u3068\u6700\u9069\u5316\u6761\u4ef6\u306b\u3088\u308a\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u6eb6\u5a92\u6a19\u6e96\u7269\u8cea\u3068\u6dfb\u52a0\u30b5\u30f3\u30d7\u30eb\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u4f8b\u3092<strong>Figure 3\uff5eFigure 5<\/strong> \u306b\u793a\u3057\u307e\u3059\u3002\u7279\u306b\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u30682-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\uff08\u7570\u6027\u4f53\u5316\u5408\u7269\uff09\u3001\u304a\u3088\u30732,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3-d3\u30682-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u306e\u5206\u96e2\u304c\u9054\u6210\u3055\u308c\u305f\u305f\u3081\u3001\u6b63\u78ba\u306a\u540c\u5b9a\u3068\u5b9a\u91cf\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\uff08<strong>Figure 4<\/strong>\uff09\u3002\u3053\u306e\u3088\u3046\u306b\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3-d3\u30682-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u3067\u306e\u5206\u96e2\u304c\u91cd\u8981\u3067\u3042\u308b\u7406\u7531\u306f\u3001\u3053\u308c\u3089\u306e\u6210\u5206\u304cm\/z 95\u306896\u3092\u9664\u304d\u3001\u307b\u307c\u3059\u3079\u3066\u306e\u30a4\u30aa\u30f3\u3092\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3067\u5171\u6709\u3057\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002\u5206\u96e2\u304c\u4e0d\u5341\u5206\u306a\u5834\u5408\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3-d3\u304c2-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\u306e\u4e3b\u8981\u306a\u78ba\u8a8d\u30a4\u30aa\u30f3\uff08m\/z 81\u304a\u3088\u307353\uff09\u306e\u4e00\u90e8\u3068\u3057\u3066\u8aa4\u691c\u51fa\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u672c\u7814\u7a76\u3067\u306f\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u304c14\u5206\u9593\u306e\u5206\u6790\u3067\u5341\u5206\u306b\u5206\u96e2\u3055\u308c\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> 10 ng\/mL \u6a19\u6e96\u7269\u8cea\u4e2d\u306e\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3092\u7528\u3044\u305f\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790\u3002\u6700\u9069\u5316\u3055\u308c\u305f\u6607\u6e29\u6761\u4ef6\u3067\u3001Rxi-624Sil MS \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u30012-\u30a8\u30c1\u30eb\u30d5\u30e9\u30f3\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3-d3\u30012,5-\u30b8\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u306e\u826f\u597d\u306a\u5206\u96e2\u3092\u9054\u6210\u3057\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1218.png\" alt=\"Furan and Alkylfurans Standards and Internal Standards in Solvent on Rxi-624Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1218<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13868<\/li><li>23280<\/li><li>23083<\/li><li>23091<\/li><li>33334<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Alkylfurans<\/li><li>Baby formula<\/li><li>Coffee<\/li><li>Furan<\/li><li>HS-SPME<\/li><li>SPME Arrow<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1218.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> 5 \u00b5g\/kg \u3067\u6dfb\u52a0\u3055\u308c\u305f\u7c89\u30df\u30eb\u30af\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1219.png\" alt=\"Furan and Alkylfurans in Baby Formula Spiked at 5 \u00b5g\/kg on Rxi-624Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1219<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13868<\/li><li>23280<\/li><li>23083<\/li><li>23091<\/li><li>33334<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Alkylfurans<\/li><li>Baby formula<\/li><li>Furan<\/li><li>HS-SPME<\/li><li>SPME Arrow<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1219.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> 1000 \u00b5g\/kg \u3067\u6dfb\u52a0\u3057\u305f\u30a4\u30f3\u30b9\u30bf\u30f3\u30c8\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1220.png\" alt=\"Furan and Alkylfurans in Instant Coffee Spiked at 1000 \u00b5g\/kg on Rxi-624Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1220<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13868<\/li><li>23280<\/li><li>23083<\/li><li>23091<\/li><li>33334<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Alkylfurans<\/li><li>Coffee<\/li><li>Furan<\/li><li>HS-SPME<\/li><li>SPME Arrow<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1220.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u76f4\u7dda\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5404\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u9069\u5207\u306a\u91cd\u6c34\u7d20\u5316\u985e\u4f3c\u4f53\u3092\u7528\u3044\u3066\u3001\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\uff0830%\uff09\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u3059\u3079\u3066\u306b\u3064\u3044\u3066\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002\u540c\u4f4d\u4f53\u6a19\u8b58\u3055\u308c\u305f\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u306e\u4f7f\u7528\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306e\u56de\u53ce\u7387\u3068\u6dfb\u52a0\u3055\u308c\u305f\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\u304b\u3089\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306e\u56de\u53ce\u7387\u306e\u9055\u3044\u3092\u8003\u616e\u3059\u308b\u305f\u3081\u306b\u4e0d\u53ef\u6b20\u3067\u3057\u305f\u3002\u672c\u7814\u7a76\u3067\u63a1\u7528\u3057\u305f\u5b9a\u91cf\u6cd5\u306f\u30012020\u5e74\u306bFrank\u3089\u306b\u3088\u3063\u3066\u767a\u8868\u3055\u308c\u305f\u65b9\u6cd5[5]\u3092\u82e5\u5e72\u4fee\u6b63\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u4f4e\u6fc3\u5ea6\u691c\u91cf\u7dda\u306e\u7bc4\u56f2\u306f\u30d0\u30a4\u30a2\u30eb\u5185\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u52061.25\uff5e150 ng\uff088\u70b9\u6821\u6b63\uff09\u3001\u9ad8\u6fc3\u5ea6\u691c\u91cf\u7dda\u306e\u7bc4\u56f2\u306f\u30d0\u30a4\u30a2\u30eb\u5185\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u520625\uff5e8000 ng\uff089\u70b9\u6821\u6b63\uff09\u3067\u3057\u305f\u3002<strong>Figure 6<\/strong>\u304b\u3089\u308f\u304b\u308b\u3088\u3046\u306b\u3001\u8a66\u9a13\u3057\u305f\u7bc4\u56f2\u5185\u3067\u306f\u3059\u3079\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u3067\u826f\u597d\u306a\u76f4\u7dda\u6027\u304c\u78ba\u8a8d\u3055\u308c\u3001\u6c7a\u5b9a\u4fc2\u6570\u306f\u3059\u3079\u30660.99\u4ee5\u4e0a\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u30da\u30f3\u30c1\u30eb\u30d5\u30e9\u30f3\u306b\u3064\u3044\u3066\u306f\u3001\u4f4e\u6fc3\u5ea6\u691c\u91cf\u7dda\u306f1.25\uff5e100 ng\u3067\u3001\u9ad8\u6fc3\u5ea6\u691c\u91cf\u7dda\u306f\u30d0\u30a4\u30a2\u30eb\u5185\u306e25\uff5e2000 ng\u306e\u7bc4\u56f2\u3067\u3001\u305d\u308c\u305e\u308c\u826f\u597d\u306a\u76f4\u7dda\u6027\u3092\u793a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6: <\/strong>SPME Arrow\u3092\u7528\u3044\u305f\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u5206\u6790\u306e\u691c\u91cf\u7dda<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAN3916-06.jpg\" alt=\"figure-article-FSAN3916-06.jpg\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u7c89\u30df\u30eb\u30af\u3068\u30b3\u30fc\u30d2\u30fc\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u306e\u691c\u8a3c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7c89\u30df\u30eb\u30af\u3068\u30b3\u30fc\u30d2\u30fc\u306e\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u76ee\u7684\u5206\u6790\u6210\u5206\u304c\u6709\u610f\u306a\u6fc3\u5ea6\u3067\u542b\u307e\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3002\u7c89\u30df\u30eb\u30af\u306b\u306f\u4f4e\u6fc3\u5ea6\u691c\u91cf\u7dda\u3001\u30a4\u30f3\u30b9\u30bf\u30f3\u30c8\u30b3\u30fc\u30d2\u30fc\u306b\u306f\u9ad8\u6fc3\u5ea6\u691c\u91cf\u7dda\u3092\u305d\u308c\u305e\u308c\u4f7f\u7528\u3057\u3066\u3001\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<strong>Table V<\/strong>\u3068<strong>Table VI<\/strong>\u306b\u3001\u5206\u6790\u7d50\u679c\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002\u7c89\u30df\u30eb\u30af\u3067\u306f\u30013-\u30e1\u30c1\u30eb\u30d5\u30e9\u30f3\u304c\u4f4e\u6fc3\u5ea6\u6dfb\u52a0\u6642\u306b\u56de\u53ce\u7387113%\u3092\u793a\u3057\u305f\u3082\u306e\u306e\u3001\u305d\u308c\u4ee5\u5916\u306e\u5206\u6790\u6210\u5206\u306f\u3059\u3079\u306680\uff5e110%\u306e\u56de\u53ce\u7387\u57fa\u6e96\u3092\u6e80\u305f\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001\u30b3\u30fc\u30d2\u30fc\u306e\u7d50\u679c\u3067\u306f\u3001\u4f4e\u6fc3\u5ea6\u6dfb\u52a0\u6642\u306f\u3059\u3079\u3066\u306e\u6210\u5206\u304c\u57fa\u6e96\u3092\u30af\u30ea\u30a2\u3057\u307e\u3057\u305f\u304c\u3001\u9ad8\u6fc3\u5ea6\u6dfb\u52a0\u6642\u306b\u306f\u56de\u53ce\u7387\u306b\u9ad8\u3044\u504f\u308a\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002\u4eca\u5f8c\u306e\u5b9f\u9a13\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30b5\u30a4\u30ba\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u53d6\u308a\u6271\u3044\u3001\u5e0c\u91c8\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8abf\u67fb\u3059\u3079\u304d\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u304c\u3001\u305d\u308c\u3067\u3082\u56de\u53ce\u7387\u306f\u4e0a\u9650\u5024\u306e110%\u306b\u8fd1\u3044\u5024\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u7d50\u679c\u304b\u3089\u3001SPME Arrow\u306f\u3001\u4f4e\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u3060\u3051\u3067\u306a\u304f\u3001\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u6709\u52b9\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3042\u308b\u53ef\u80fd\u6027\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table V:<\/strong> \u7c89\u30df\u30eb\u30af\u4e2d\u306e\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/td><td colspan=\"2\"><strong>\u30d6\u30e9\u30f3\u30af (n=3)<\/strong><\/td><td colspan=\"2\"><strong>\u4f4e\u6fc3\u5ea6\u3000(n=3),<\/strong> <strong>5 \u00b5g\/kg*<\/strong><\/td><td colspan=\"2\"><strong>\u9ad8\u6fc3\u5ea6 (n=3),<\/strong> <strong>50 \u00b5g\/kg*<\/strong><\/td><\/tr><tr><td><strong>\u6fc3\u5ea6, \u00b5g\/kg<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><td><strong>\u7cbe\u5ea6, %<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><td><strong>\u7cbe\u5ea6, %<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><\/tr><tr><td>Furan<\/td><td>16<\/td><td>1<\/td><td>110<\/td><td>2<\/td><td>94<\/td><td>4<\/td><\/tr><tr><td>2-Methylfuran<\/td><td>60<\/td><td>2<\/td><td>97<\/td><td>2<\/td><td>100<\/td><td>3<\/td><\/tr><tr><td>3-Methylfuran<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>113<\/td><td>3<\/td><td>107<\/td><td>6<\/td><\/tr><tr><td>2-Ethylfuran<\/td><td>67<\/td><td>2<\/td><td>93<\/td><td>3<\/td><td>105<\/td><td>5<\/td><\/tr><tr><td>2,5-Dimethylfuran<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>101<\/td><td>4<\/td><td>97<\/td><td>14<\/td><\/tr><tr><td>2-Pentylfuran<\/td><td>219<\/td><td>3<\/td><td>87<\/td><td>11<\/td><td>108<\/td><td>12<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u7cbe\u5ea6\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u6c42\u3081\u307e\u3057\u305f\uff1a ((\u6e2c\u5b9a\u6fc3\u5ea6-\u30d6\u30e9\u30f3\u30af\u6fc3\u5ea6)\/\u6dfb\u52a0\u5f8c\u306e\u6fc3\u5ea6)*100<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table VI:<\/strong> \u30a4\u30f3\u30b9\u30bf\u30f3\u30c8\u30b3\u30fc\u30d2\u30fc\u4e2d\u306e\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\"><strong>\u5206\u6790\u5bfe\u8c61\u6210\u5206<\/strong><\/td><td colspan=\"2\"><strong>\u30d6\u30e9\u30f3\u30af (n=3)<\/strong><\/td><td colspan=\"2\"><strong>\u4f4e\u6fc3\u5ea6 (n=3),<\/strong> <strong>1000 \u00b5g\/kg*<\/strong><\/td><td colspan=\"2\"><strong>\u9ad8\u6fc3\u5ea6 (n=3),<\/strong> <strong>4000 \u00b5g\/kg*<\/strong><\/td><\/tr><tr><td><strong>\u6fc3\u5ea6, \u00b5g\/kg<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><td><strong>\u7cbe\u5ea6, %<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><td><strong>\u7cbe\u5ea6, %<\/strong><\/td><td><strong>RSD, %<\/strong><\/td><\/tr><tr><td>Furan<\/td><td>394<\/td><td>10<\/td><td>87<\/td><td>2<\/td><td>125<\/td><td>3<\/td><\/tr><tr><td>2-Methylfuran<\/td><td>843<\/td><td>10<\/td><td>94<\/td><td>3<\/td><td>116<\/td><td>2<\/td><\/tr><tr><td>3-Methylfuran<\/td><td>96<\/td><td>10<\/td><td>87<\/td><td>2<\/td><td>119<\/td><td>3<\/td><\/tr><tr><td>2-Ethylfuran<\/td><td>29<\/td><td>11<\/td><td>93<\/td><td>2<\/td><td>115<\/td><td>5<\/td><\/tr><tr><td>2,5-Dimethylfuran<\/td><td>46<\/td><td>11<\/td><td>98<\/td><td>2<\/td><td>120<\/td><td>4<\/td><\/tr><tr><td>2-Pentylfuran<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>83<\/td><td>3<\/td><td>83<\/td><td>11<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*\u7cbe\u5ea6\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u6c42\u3081\u307e\u3057\u305f\uff1a ((\u6e2c\u5b9a\u6fc3\u5ea6-\u30d6\u30e9\u30f3\u30af\u6fc3\u5ea6)\/\u6dfb\u52a0\u5f8c\u306e\u6fc3\u5ea6)*100<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306e\u5206\u6790\u306f\u3001\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u5e45\u5e83\u3044\u6fc3\u5ea6\u7bc4\u56f2\u3067\u5b58\u5728\u3057\u5f97\u308b\u591a\u69d8\u306a\u30b5\u30f3\u30d7\u30eb\u30bf\u30a4\u30d7\u3092\u6271\u3046\u305f\u3081\u3001\u975e\u5e38\u306b\u8907\u96d1\u3067\u3059\u3002\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\u3001\u4f4e\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u5f93\u6765\u578b\u306eSPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3092\u7528\u3044\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u672c\u7814\u7a76\u3067\u306f\u3001\u3059\u3079\u3066\u306e\u6fc3\u5ea6\u30ec\u30d9\u30eb\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206\u306b\u5bfe\u5fdc\u53ef\u80fd\u306a\u5358\u4e00\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u78ba\u7acb\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u307e\u3057\u305f\u3002\u3053\u3053\u3067\u958b\u767a\u3057\u305fSPME Arrow\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306f\u3001\u4f4e\u6fc3\u5ea6\uff08\u7c89\u30df\u30eb\u30af\u306e\u5834\u5408\uff1a5\u304a\u3088\u307350 \u00b5g\/kg\uff09\u304a\u3088\u3073\u9ad8\u6fc3\u5ea6\uff08\u30b3\u30fc\u30d2\u30fc\u306e\u5834\u5408\uff1a1000\u304a\u3088\u30734000 \u00b5g\/kg\uff09\u306e\u30b9\u30d1\u30a4\u30af\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u304a\u3044\u3066\u8a55\u4fa1\u3055\u308c\u3001\u307b\u3068\u3093\u3069\u306e\u30b1\u30fc\u30b9\u3067\u3001\u76f4\u7dda\u6027\u3001\u7cbe\u5ea6\u3001\u518d\u73fe\u6027\u306e\u70b9\u3067\u6e80\u8db3\u306e\u3044\u304f\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u306b\u306f\u3001\u7570\u306a\u308b\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\uff081:100\uff09\u3001\u62bd\u51fa\u6642\u9593\uff081\u5206\uff09\u3001\u304a\u3088\u3073\u5869\u5316\u30ca\u30c8\u30ea\u30a6\u30e0\u6eb6\u6db2\uff0830%\uff09\uff085 mL\uff09\u306e\u6761\u4ef6\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u3055\u3089\u306a\u308b\u6700\u9069\u5316\u304c\u5fc5\u8981\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0a\u306e\u3053\u3068\u304b\u3089\u3001\u672c\u7814\u7a76\u3067\u793a\u3055\u308c\u305f\u3053\u306eSPME Arrow GC-MS\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u5358\u4e00\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6280\u8853\u3067\u9ad8\u6fc3\u5ea6\u304a\u3088\u3073\u4f4e\u6fc3\u5ea6\u306e\u4e21\u65b9\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u305f\u3081\u3001\u5206\u6790\u30e9\u30dc\u306e\u52b9\u7387\u6027\u3084\u751f\u7523\u6027\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u308b\u624b\u6cd5\u3068\u306a\u308a\u5f97\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References\u3000\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>European Commission recommendation 2022\/495, On monitoring the presence of furan and alkylfurans in food, 2022.&nbsp;<a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/HTML\/?uri=CELEX:32022H0495&amp;from=EN#ntr1-L_2022100EN.01006001-E0001\" target=\"_blank\" rel=\"noopener\">https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/HTML\/?uri=CELEX:32022H0495&amp;from=EN#ntr1-L_2022100EN.01006001-E0001<\/a><\/li>\n\n\n\n<li>Reyes-Garc\u00e9s, <a href=\"https:\/\/discover.restek.com\/blogs\/gnbl4573\/analysis-of-furans-and-alkylfurans-in-food-samples-part-1\">Analysis of furan and alkylfurans in food (part 1): choosing GC-MS conditions and a sample preparation technique<\/a>, ChromaBLOGraphy, Restek Corporation, 2022.\u00a0<\/li>\n\n\n\n<li>Reyes-Garc\u00e9s, <a href=\"https:\/\/discover.restek.com\/blogs\/gnbl4572\/analysis-of-furan-and-alkylfurans-in-food-samples-part-2\">Analysis of furan and alkylfurans in food (part 2): optimizing experimental conditions for the analysis of food matrices using the SPME Arrow<\/a>, ChromaBLOGraphy, Restek Corporation, 2022.<\/li>\n\n\n\n<li>Reyes-Garc\u00e9s, Analysis of furan and alkylfurans in food samples (part 3): Adjusting the experimental conditions for the analysis of samples with high concentrations of analytes and preparing calibration curves, ChromaBLOGraphy, Restek Corporation, 2022.<\/li>\n\n\n\n<li>Frank, M. Dubois, J.F. Huertas P\u00e9rez, Detection of furan and five alkylfurans, including 2-pentylfuran, in various food matrices, J. Chromatogr. A, 1622 (2020) 461119.&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.chroma.2020.461119\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1016\/j.chroma.2020.461119<\/a><\/li>\n\n\n\n<li>AOAC SMPR 2019.004, Standard method performance requirements (SMPRs) for furan and alkyl furans in coffee, baby foods, infant formula, cereals, and fruit juices, final version: October 3, 2019, AOAC International, Rockville, MD, U.S.&nbsp;<a href=\"https:\/\/www.aoac.org\/wp-content\/uploads\/2019\/09\/SMPR_Furans_v6-For-Comment.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.aoac.org\/wp-content\/uploads\/2019\/09\/SMPR_Furans_v6-For-Comment.pdf<\/a><\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-7-background-color has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-1ba01d3be454e0391dc4c739d9c0909c wp-block-paragraph\"><strong>\u30d5\u30e9\u30f3\uff0f\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u6a19\u6e96\u7269\u8cea\u3092\u304a\u63a2\u3057\u3067\u3059\u304b\uff1f<\/strong> <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30e9\u30f3\uff0f\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u591a\u6210\u5206\u6a19\u6e96\u7269\u8cea (<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/33334\" target=\"_blank\" rel=\"noopener\">cat.# 33334<\/a>)\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"384\" height=\"118\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-reference-standards-furan-alkylfurans.png\" alt=\"\" class=\"wp-image-29787\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-reference-standards-furan-alkylfurans.png 384w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-reference-standards-furan-alkylfurans-300x92.png 300w\" sizes=\"auto, (max-width: 384px) 100vw, 384px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33334\">                                \u30ab\u30bf\u30ed\u30b0No. 33334                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u30d5\u30e9\u30f3\uff0f\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u5206\u6790 \u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff5cGC-MS\u30fb\u98df\u54c1\u5206\u6790\u5bfe\u5fdc<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33334\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33335\">                                \u30ab\u30bf\u30ed\u30b0No. 33335                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u30d5\u30e9\u30f3\uff0f\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u5206\u6790\u7528 \u5185\u90e8\u6a19\u6e96\u6df7\u5408\u6db2 Mix 1\uff5cGC-MS\u30fb\u98df\u54c1\u5206\u6790\u5bfe\u5fdc<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33335\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>SPME Arrow\u3001SPME\u30d5\u30a1\u30a4\u30d0\u30fc\u3001\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\uff08HS\uff09\u3092\u6bd4\u8f03\u3057\u3001\u98df\u54c1\u4e2d\u30d5\u30e9\u30f3\u304a\u3088\u3073\u30a2\u30eb\u30ad\u30eb\u30d5\u30e9\u30f3\u306eGC-MS\u5206\u6790\u6cd5\u3092\u691c\u8a0e\u3002\u7c89\u30df\u30eb\u30af\u3084\u30b3\u30fc\u30d2\u30fc\u3067\u306e\u6700\u9069\u5316\u6761\u4ef6\u3092\u78ba\u7acb\u3057\u3001\u98df\u54c1\u5b89\u5168\u691c\u67fb\u306e\u52b9\u7387\u5316\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":6967,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-45329","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSAN3916-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45329"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45329\/revisions"}],"predecessor-version":[{"id":81265,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45329\/revisions\/81265"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6967"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45329"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45329"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45329"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45329"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45329"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45329"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45329"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45329"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}