{"id":45332,"date":"2025-10-08T17:56:17","date_gmt":"2025-10-08T17:56:17","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/improve-narrow-bore-gc-column-performance-with-intermediate-volume-iv-inlet-liners-japan\/"},"modified":"2026-10-02T17:36:50","modified_gmt":"2026-10-02T17:36:50","slug":"improve-narrow-bore-gc-column-performance-with-intermediate-volume-iv-inlet-liners-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4184-ja\/improve-narrow-bore-gc-column-performance-with-intermediate-volume-iv-inlet-liners-japan","title":{"rendered":"\u5185\u5f843mm\u306e\u4e2d\u5bb9\u91cf\uff08IV\uff09\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u3088\u308b\u30ca\u30ed\u30fc\u30dc\u30a2GC\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u5411\u4e0a\u306b\u3064\u3044\u3066"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>\u30ca\u30ed\u30fc\u30dc\u30a2GC\u30ab\u30e9\u30e0\uff08\u5185\u5f840.25mm\u672a\u6e80\uff09\u306e\u7279\u6027\u3092\u6700\u5927\u9650\u306b\u6d3b\u304b\u3059\u3053\u3068\u3067\u3001\u8fc5\u901f\u3067\u9ad8\u611f\u5ea6\u304b\u3064\u3001\u9ad8\u3044\u518d\u73fe\u6027\u3092\u3082\u3063\u305f\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u5bb9\u91cf\u3092\u4fdd\u6301\u3057\u306a\u304c\u3089\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u512a\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u79fb\u52d5\u901f\u5ea6\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u4e2d\u306e\u30b5\u30f3\u30d7\u30eb\u62e1\u6563\u3084\u5206\u6790\u7269\u306e\u5206\u89e3\u306e\u53ef\u80fd\u6027\u3092\u4f4e\u6e1b\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns has-theme-palette-8-background-color has-background is-layout-flex wp-container-core-columns-is-layout-dc9fa487 wp-block-columns-is-layout-flex\" style=\"border-width:1px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">\u9ad8\u52b9\u7387\u306e\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u5229\u70b9\u3092\u6700\u5927\u9650\u767a\u63ee\u3059\u308b\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u306b\u3064\u3044\u3066\u3082\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<em><br>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u4e2d\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3082\u305f\u3089\u3055\u308c\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068 <a href=\"#reproduciblity\">\u518d\u73fe\u6027<\/a>\u306e\u6539\u5584\u306b\u3064\u3044\u3066\u3001\u4ee5\u4e0b\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u3082\u3068\u306b\u8aac\u660e\u3057\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#svoc\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269 (SVOC\uff09<\/a><\/li>\n\n\n\n<li><a href=\"#pah\">\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20 (PAHs)<\/a><\/li>\n\n\n\n<li><a href=\"#pesticides\">\u8fb2\u85ac<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">  <em><a href=\"#summary\">\u300c\u5168\u4f53\u7684\u306a\u8a55\u4fa1\u300d\u3092\u898b\u308b<\/a><\/em><\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">IV\u30e9\u30a4\u30ca\u30fc\u306e\u30a4\u30f3\u30c8\u30ed\u30c0\u30af\u30b7\u30e7\u30f3 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u308b\u3068\u751f\u7523\u6027\u304c\u5411\u4e0a\u3057\u307e\u3059\u304c\u3001\u3053\u308c\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6027\u80fd\u304c\u3001\u3088\u308a\u6b63\u78ba\u306a\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3068\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3042\u308b\u5834\u5408\u306b\u9650\u308a\u307e\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\uff08\u5185\u5f840.25 mm\u672a\u6e80\uff09\u306f\u3001\u30ab\u30e9\u30e0\u52b9\u7387\u304c\u9ad8\u304f\u3001\u30d4\u30fc\u30af\u306e\u8b58\u5225\u304c\u5bb9\u6613\u306a\u9ad8\u304f\u3066\u30b7\u30e3\u30fc\u30d7\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u9ad8\u3044\u30ab\u30e9\u30e0\u52b9\u7387\u306f\u3001\u30ab\u30e9\u30e0\u6d41\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u3067\u9054\u6210\u3055\u308c\u3001\u3053\u308c\u306b\u3088\u308a\u5206\u6790\u7269\u304c\u30ab\u30e9\u30e0\u56fa\u5b9a\u76f8\u3068\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u6642\u9593\u304c\u5897\u3048\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u3001\u3088\u308a\u8584\u3044\u6db2\u76f8\u3068\u77ed\u3044\u30ab\u30e9\u30e0\u9577\u3067\u767a\u751f\u3059\u308b\u305f\u3081\u3001\u5206\u6790\u7269\u306f\u72ed\u304f\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u3068\u3057\u3066\u8fc5\u901f\u306b\u6eb6\u51fa\u3057\u307e\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u3001\u4e00\u822c\u7684\u306aGC-MS\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3067\u9ad8\u901f\u304b\u3064\u9ad8\u52b9\u7387\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u9054\u6210\u3059\u308b\u826f\u3044\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3059\u304c\u3001\u305d\u306e\u6709\u52b9\u6027\u306f\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u306b\u3088\u3063\u3066\u5236\u9650\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u3092\u5236\u5fa1\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u6ce8\u5165\u53e3\u304c\u5229\u7528\u53ef\u80fd\u3067\u3059\u304c\u3001\u3082\u3063\u3068\u3082\u4e00\u822c\u7684\u306a\u30c4\u30fc\u30eb\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\/\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u3067\u3059\u3002\u540c\u69d8\u306b\u3001\u591a\u304f\u306e\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u5f62\u72b6\u3084\u5185\u5f84\u304c\u5229\u7528\u53ef\u80fd\u3067\u3059\u304c\u3001\u307b\u3068\u3093\u3069\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\/\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u306b\u306f\u3001\u5185\u5f84\uff08ID\uff09\u304c\u7d042 mm\uff08\u300c\u5c0f\u5bb9\u91cf\u300d\uff09\u307e\u305f\u306f\u7d043.5\uff5e4 mm\uff08\u300c\u5927\u5bb9\u91cf\u300d\uff09\u306e\u30e9\u30a4\u30ca\u30fc\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3067\u306f\u3001\u5c0f\u3055\u306a\u30e9\u30a4\u30ca\u30fc\u304c\u3088\u308a\u901f\u3044\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u3068\u5c0e\u5165\u3092\u63d0\u4f9b\u3057\u3001\u30ab\u30e9\u30e0\u306e\u52b9\u7387\u3092\u3055\u3089\u306b\u88dc\u5b8c\u3057\u307e\u3059\u304c\u3001\u305d\u308c\u305e\u308c\u306e\u5185\u5f84\u306b\u306f\u8003\u616e\u3059\u3079\u304d\u5229\u70b9\u3068\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\uff08<strong>Table I<\/strong>\uff09\u3002\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u306f\u3001\u6700\u7d42\u7684\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u91cf\u3068\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6027\u80fd\u306e\u89b3\u70b9\u3067\u30c8\u30ec\u30fc\u30c9\u30aa\u30d5\u3059\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u7570\u306a\u308b\u30b5\u30a4\u30ba\u306e\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u5229\u70b9\u3068\u5236\u9650<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30e1\u30ea\u30c3\u30c8<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30c7\u30e1\u30ea\u30c3\u30c8<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u6ede\u7559\u6642\u9593\u304c\u77ed\u3044\u3068\u3001\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u6642\u9593\u304c\u65e9\u304f\u306a\u308a\u3001\u5206\u6790\u5bfe\u8c61\u7269\u306e\u30d0\u30f3\u30c9\u304c\u72ed\u304f\u306a\u308b\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u306e\u30db\u30fc\u30eb\u30c9\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u308b\u3002 \u5206\u6790\u5bfe\u8c61\u7269\u306e\u30d0\u30f3\u30c9\u304c\u72ed\u3044\u3068\u3001\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3059\u308b\u3002 \u6d3b\u6027\u5316\u5408\u7269\u304c\u30e9\u30a4\u30ca\u30fc\u5185\u306b\u7559\u307e\u308b\u6642\u9593\u3092\u77ed\u7e2e\u3057\u3001\u5438\u7740\u3084\u53cd\u5fdc\u6027\u306a\u3069\u306e\u6709\u5bb3\u306a\u76f8\u4e92\u4f5c\u7528\u304c\u8efd\u6e1b\u3055\u308c\u308b\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u304c\u5c0f\u3055\u304f\u306a\u308b\u3068\u3001\u6ce8\u5165\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u91cf\u304c\u6e1b\u308a\u3001\u611f\u5ea6\u3068\u518d\u73fe\u6027\u306e\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308b\u3002 \u6eb6\u5a92\u306e\u6c17\u5316\u4f53\u7a4d\u304c\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u3092\u8d85\u3048\u308b\u3068\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u304c\u767a\u751f\u3057\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u60aa\u5316\u3057\u3001\u7d50\u679c\u306e\u3070\u3089\u3064\u304d\u3001\u6ce8\u5165\u53e3\u306e\u6c5a\u67d3\u306e\u53ef\u80fd\u6027\u304c\u3042\u308b\u3002<\/td><\/tr><tr><td>\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc &nbsp; &nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u304c\u5927\u304d\u3044\u3068\u3001\u6ce8\u5165\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u91cf\u3082\u5897\u3048\u611f\u5ea6\u3068\u518d\u73fe\u6027\u304c\u5411\u4e0a\u3059\u308b\u3002 \u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u304c\u5927\u304d\u3044\u3068\u3001\u6c17\u5316\u4f53\u7a4d\u306e\u9ad8\u3044\u6eb6\u5a92\uff08\u6c34\u306a\u3069\uff09\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306e\u53ef\u80fd\u6027\u304c\u4f4e\u304f\u306a\u308b\u3002<\/td><td class=\"has-text-align-left\" data-align=\"left\">\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u304c\u5927\u304d\u304f\u306a\u308b\u3068\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u3001\u30d4\u30fc\u30af\u5e45\u306e\u5897\u52a0\u3001\u30d4\u30fc\u30af\u9ad8\u3055\u4f4e\u4e0b\u306b\u7e4b\u304c\u308b\u3002 \u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306f\u30ab\u30e9\u30e0\u6d41\u91cf\u304c\u4f4e\u3044\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30b5\u30f3\u30d7\u30eb\u6ede\u7559\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u3001\u5206\u6790\u7a2e\u306e\u5206\u89e3\u306b\u7e4b\u304c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e1\u30bd\u30c3\u30c9\u306e\u691c\u51fa\u9650\u754c\u3092\u4e0b\u3052\u3066\u3001\u611f\u5ea6\u3092\u9ad8\u3081\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306f\u6ce8\u5165\u91cf\u304c\u91cd\u8981\u3067\u3059\u3002\u6ce8\u5165\u91cf\u3092\u5897\u3084\u3059\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u3092\u5897\u3084\u3059\u3053\u3068\u304c\u3067\u304d\u3001\u524d\u51e6\u7406\u306e\u624b\u9806\u3092\u5909\u66f4\u3059\u308b\u5fc5\u8981\u3082\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u6ce8\u5165\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u3059\u3079\u3066\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3059\u308b\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u3088\u3063\u3066\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6642\u3067\u306e\u6ce8\u5165\u91cf\u3092\u6700\u5927\u5316\u3059\u308b\u3068\u3001\u6ce8\u5165\u53e3\u306e\u6e29\u5ea6\u3001\u5727\u529b\u3001\u304a\u3088\u3073\u5206\u6790\u7269\u306e\u6eb6\u89e3\u5ea6\u306b\u5927\u304d\u304f\u5f71\u97ff\u3092\u4e0e\u3048\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u54c1\u8cea\u304c\u4f4e\u4e0b\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30d0\u30e9\u30f3\u30b9\u3092\u3068\u308b\u306e\u306f\u7c21\u5358\u306a\u4f5c\u696d\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u305d\u306e\u3088\u3046\u306a\u5834\u5408\u306bRestek\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/solvent-expansion-calculator\" target=\"_blank\" rel=\"noopener\">\u6eb6\u5a92\u6c17\u5316\u5bb9\u91cf\u30ab\u30ea\u30ad\u30e5\u30ec\u30fc\u30bf\uff08solvent expansion calculator)<\/a> \u304c\u5f79\u7acb\u3061\u307e\u3059\u3002<strong>Figure 1<\/strong>\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3068\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u6ce8\u5165\u53e3\u306e\u6761\u4ef6\u4e0b\u3067\u3001\u7570\u306a\u308b\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3067\u8a08\u7b97\u3055\u308c\u305f\u6ce8\u5165\u91cf\u306e\u6700\u5927\u5024\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u3082\u3061\u308d\u3093\u3001\u6eb6\u5a92\u306b\u3088\u3063\u3066\u7d50\u679c\u306f\u7570\u306a\u308a\u307e\u3059\u304c\u3001\u4e00\u822c\u7684\u306b\u5c0f\u3055\u306a\u30e9\u30a4\u30ca\u30fc\u306f0.5\u301c1 \u00b5L\u3092\u4fdd\u6301\u3067\u304d\u308b\u305f\u3081\u3001\u691c\u51fa\u9650\u754c\u304c\u8db3\u308a\u306a\u3044\u5834\u5408\u306f\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306e\u5bb9\u91cf\u5897\u52a0\u306f\u30ab\u30e9\u30e0\u52b9\u7387\u306e\u4f4e\u4e0b\u304c\u4f34\u3044\u307e\u3059\u3002\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u5185\u3092\u6d41\u308c\u308b\u5206\u6790\u7269\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u5165\u53e3\u306b\u5411\u304b\u3063\u3066\u3001\u975e\u5e38\u306b\u9045\u3044\u901f\u5ea6\u3067\u79fb\u52d5\u3059\u308b\u305f\u3081\u30d4\u30fc\u30af\u304c\u5e83\u304c\u308a\u3001\u307e\u305f\u5206\u6790\u7269\u304c\u30e9\u30a4\u30ca\u30fc\u3068\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u6642\u9593\u3092\u4e0e\u3048\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u7279\u306b\u30a8\u30f3\u30c9\u30ea\u30f3\u3084DDT\u306a\u3069\u306e\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3067\u5206\u89e3\u3059\u308b\u5316\u5408\u7269\u306b\u3068\u3063\u3066\u6709\u5bb3\u3068\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> \u6ce8\u5165\u6eb6\u5a92\u3001\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3001\u304a\u3088\u3073\u6761\u4ef6\u306b\u3088\u3063\u3066\u6700\u5927\u6ce8\u5165\u91cf\uff08Maximum Injection Volume\uff1a\u00b5L\uff09\u304c\u7570\u306a\u308a\u307e\u3059\uff08\u30c7\u30fc\u30bf\u306f250\u00b0C\u304a\u3088\u307340 psi\u3067\u53ce\u96c6\u3055\u308c\u307e\u3057\u305f\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnar4184-01.jpg\" alt=\"Maximum injection volume varies by solvent and liner size; consider both to minimize solvent effects.\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">IV\u30e9\u30a4\u30ca\u30fc\u304c\u3088\u308a\u30d0\u30e9\u30f3\u30b9\u306e\u53d6\u308c\u305f\u89e3\u6c7a\u7b56\u3092\u63d0\u4f9b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u30e6\u30fc\u30b6\u30fc\u306b\u3055\u3089\u306a\u308b\u67d4\u8edf\u6027\u3092\u4e0e\u3048\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306e\u30ea\u30b9\u30af\u3084\u30d4\u30fc\u30af\u7279\u6027\u3092\u640d\u306a\u3046\u3053\u3068\u306a\u304f\u6700\u5927\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3067\u304d\u308b\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u306b\u3001Restek\u306f\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\uff08\u5185\u5f843 mm\uff09\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u5c0f\u5bb9\u91cf\uff082 mm\uff09\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u306f\u6eb6\u5a92\u6c17\u5316\u4f53\u7a4d\u3092\u542b\u3080\u5927\u5e45\u306a\u4f59\u88d5\u304c\u3042\u308b\u305f\u3081\u3001\u6ce8\u5165\u91cf\u30922\u500d\u306b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u5927\u5bb9\u91cf\uff084 mm\uff09\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u901f\u3044\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u529b\u3092\u6301\u3064\u305f\u3081\u3001\u5206\u6790\u7269\u306f\u6ce8\u5165\u53e3\u5185\u306b\u6ede\u5728\u3059\u308b\u6642\u9593\u304c\u77ed\u304f\u3001\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u304c\u7dad\u6301\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IV\u30e9\u30a4\u30ca\u30fc\u306e\u5229\u70b9\u3092\u5b9f\u8a3c\u3059\u308b\u305f\u3081\u306b\u3001\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20(PAHs)\u3001\u304a\u3088\u3073\u8fb2\u85ac\u3092\u5bfe\u8c61\u306b\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3068\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3057\u305f3\u7a2e\u985e\u306e\u30e9\u30a4\u30ca\u30fc\uff08IV\u30e9\u30a4\u30ca\u30fc\/\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\/\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff09\u306e\u6027\u80fd\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u5168\u4f53\u3068\u3057\u3066\u7d50\u679c\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u5bb9\u91cf\u304c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3067\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u518d\u73fe\u6027\u3092\u5927\u5e45\u306b\u6539\u5584\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u691c\u8a3c\u306f\u3001Agilent\u306eGC\u88c5\u7f6e\u306b\u9069\u3057\u305f\u5f62\u72b6\u3067\u306e\u5185\u5f842\u30013\u3001\u304a\u3088\u30734mm\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u6bd4\u8f03\u3057\u305f\u3053\u3068\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002Thermo TRACE 1300\u304a\u3088\u30731600\u30b7\u30ea\u30fc\u30ba\u3001PerkinElmer Clarus 590\/690\u304a\u3088\u3073GC2400\u3001Scion 8300\u304a\u3088\u30738500\u3001Scion\/Bruker\/Varian 1177\u3001\u304a\u3088\u3073Lucidity GC\u3001Shimadzu 17A\u30012010\u30012014\u3001\u304a\u3088\u30732030 GC\u3068\u4e92\u63db\u6027\u306e\u3042\u308bIV\u30e9\u30a4\u30ca\u30fc\u3082\u5229\u7528\u53ef\u80fd\u3067\u3042\u308a\u3001\u540c\u69d8\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"svoc\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3078\u306e\u4e2d\u5bb9\u91cfIV\u30e9\u30a4\u30ca\u30fc\u306e\u5f71\u97ff\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u306eRxi-SVOCms\u30ab\u30e9\u30e0\uff0820 m \u00d7 0.15 mm ID \u00d7 0.15 \u00b5m; \u30ab\u30bf\u30ed\u30b0\u756a\u53f7 46616\uff09\u3068\u7d44\u307f\u5408\u308f\u305b\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u304c\u9078\u629e\u3055\u308c\u305f\u7406\u7531\u306f\u3001\u7279\u306b\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5bff\u547d\u3001\u4e0d\u6d3b\u6027\u3001\u4e00\u8cab\u6027\u3001\u304a\u3088\u3073\u5206\u96e2\u80fd\u306e\u5411\u4e0a\u3092\u76ee\u7684\u3068\u3057\u3066\u8a2d\u8a08\u3055\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u30ab\u30e9\u30e0\u306f\u77ed\u3044\u5206\u6790\u6642\u9593\u3067\u540c\u3058\u5206\u96e2\u80fd\u304c\u5f97\u3089\u308c\u307e\u3059\u304c\u3001\u91cd\u8981\u306a\u5206\u96e2\u3092\u7dad\u6301\u3059\u308b\u306b\u306f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0e\u5165\u304c\u4e0d\u53ef\u6b20\u306b\u306a\u308a\u307e\u3059\u3002\u6eb6\u5a92\u306e\u5f71\u97ff\u3084\u9593\u9055\u3063\u305f\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u629e\u3092\u3057\u3066\u3057\u307e\u3046\u3068\u3001\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u304c\u767a\u751f\u3057\u3001\u5206\u96e2\u304c\u5931\u308f\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8a55\u4fa1\u3067\u306f\u30011 \uff5e 10 \u00b5g\/mL \u306b\u5e0c\u91c8\u3057\u305f 51 \u7a2e\u985e\u306e\u534a\u63ee\u767a\u6027\u5316\u5408\u7269 (\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 31899\u300131825\u300131826\u3001\u304a\u3088\u3073 32418) \u306e\u30d4\u30fc\u30af\u7279\u6027\u3068\u5206\u96e2\u80fd\u3092\u8abf\u3079\u307e\u3057\u305f\u3002\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf\u3092\u8d85\u3048\u305a\u306b\u4ed6\u306e\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3068\u6027\u80fd\u3092\u6bd4\u8f03\u3059\u308b\u305f\u3081\u306b\u3001\u5c0f\u5bb9\u91cf\uff08\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 23316\uff09\u304a\u3088\u3073\u4e2d\u5bb9\u91cf\uff08\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 27231\uff09\u306e\u30e9\u30a4\u30ca\u30fc\u306b\u306f0.5 \u00b5L \u306e\u6ce8\u5165\u3092 6 \u56de\u884c\u3044\u3001\u5927\u304d\u3044\u5bb9\u91cf\uff08\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 23303\uff09\u306e\u30e9\u30a4\u30ca\u30fc\u306b\u306f1 \u00b5L \u306e\u6ce8\u5165\u3092 6 \u56de\u884c\u3044\u307e\u3057\u305f\u3002\u5316\u5408\u7269\u3068\u6ce8\u5165\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u5168\u4f53\u3067\u30d4\u30fc\u30af\u9762\u7a4d\u3001\u9ad8\u3055\u3001\u5e45\u3001\u5206\u96e2\u80fd\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u3067\u3001\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u306b IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306e\u91cd\u8981\u306a\u5229\u70b9\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e2d\u5bb9\u91cf\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3067\u306e1 \u00b5L\u6ce8\u5165\u3092\u6bd4\u8f03\u3059\u308b\u3068\u3001\u4e2d\u5bb9\u91cfIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u307b\u3068\u3093\u3069\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3057\u305f\uff08Student\u2019s t-test, p &lt; 0.05\uff09\u3002\u3053\u306e\u7d50\u679c\u306f\u3001\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3068\u5b9a\u91cf\u304c\u5bb9\u6613\u3067\u3042\u308a\u3001\u3088\u308a\u6b63\u78ba\u306b\u306a\u308a\u307e\u3057\u305f\u3002<strong>Figure 2<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u300192% \u306e\u5316\u5408\u7269\u304c\u3088\u308a\u5927\u304d\u306a\u5e73\u5747\u30d4\u30fc\u30af\u9762\u7a4d\u3092\u793a\u3057\u300180% \u304c\u3088\u308a\u5927\u304d\u306a\u5e73\u5747\u30d4\u30fc\u30af\u9ad8\u3055\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u30d4\u30fc\u30af\u5e45\u3001\u5206\u96e2\u80fd\u3001\u304a\u3088\u3073\u5bfe\u79f0\u6027\u306f\u3001\u307b\u3068\u3093\u3069\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306e\u7d50\u679c\u3068\u7d71\u8a08\u7684\u306b\u6709\u610f\u3068\u898b\u3089\u308c\u308b\u9055\u3044\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u6eb6\u5a92\u306e\u5f71\u97ff\u306b\u3088\u308a\u3001\u4e21\u65b9\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u4e00\u90e8\u306e\u6eb6\u51fa\u306e\u65e9\u3044\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u60aa\u304f\u306a\u308b\u3053\u3068\u304c\u539f\u56e0\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\uff08<strong>Figure 3<\/strong>\uff09\u3002 \u6ce8\u5165\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u91cf\u3092\u6e1b\u3089\u3057\u305f\u5834\u5408\u3001\u6eb6\u51fa\u306e\u65e9\u3044\u5316\u5408\u7269\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5168\u4f53\u3068\u3057\u3066\u3001\u9045\u304f\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3082\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\uff08<strong>Figures 4\u20135<\/strong>\uff09\u3002\u3053\u308c\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u306e\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u304c\u9ad8\u901f\u5316\u3057\u305f\u7d50\u679c\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">0.5 \u00b5L \u6ce8\u5165\u3067\u306f\u3001\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u4e2d\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u6bd4\u8f03\u3057\u305f\u3068\u3053\u308d\u3001\u305d\u306e\u5dee\u306f\u3088\u308a\u5287\u7684\u3067\u3057\u305f\u3002IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u5206\u6790\u5bfe\u8c61\u306e\u3059\u3079\u3066\u306e\u30d4\u30fc\u30af\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3067\u7d71\u8a08\u7684\u306b\u6709\u610f\u306a\u6539\u5584\u304c\u793a\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 2<\/strong>\uff09\u3002\u3053\u308c\u3089\u306e\u5229\u70b9\u306f\u3001\u72ed\u3044\u30b5\u30f3\u30d7\u30eb\u79fb\u52d5\u5e2f\u57df\u3092\u63d0\u4f9b\u3057\u3001\u6eb6\u5a92\u30d4\u30fc\u30af\u304b\u3089\u306e\u5206\u96e2\u3092\u7dad\u6301\u3059\u308b IV\u30e9\u30a4\u30ca\u30fc\u306b\u8d77\u56e0\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u6027\u80fd\u306e\u5411\u4e0a\u306f\u3001\u30d9\u30f3\u30be[b]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3084\u30d9\u30f3\u30be[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u306a\u3069\u3001\u8fd1\u304f\u306b\u6eb6\u51fa\u3059\u308b\u6cb8\u70b9\u306e\u8fd1\u3044\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u96e2\u3092\u5411\u4e0a\u3055\u305b\u308b\u306e\u306b\u7279\u306b\u6709\u76ca\u3067\u3057\u305f\uff08resolution of 1.83 vs. 1.93 on the 2 mm and 3 mm liner, respectively, p &lt; 0.05\uff09\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3044\u3066\u3001IV\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306b\u5909\u63db\u3057\u3066\u3082\u3001\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5206\u96e2\u3092\u63d0\u4f9b\u3057\u3001\u9ad8\u4e0d\u6d3b\u6027\u3067\u9ad8\u52b9\u7387\u306e Rxi-SVOCms \u30ab\u30e9\u30e0\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u30ca\u30ed\u30fc\u30dc\u30a2Rxi-SVOCms\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3078\u306e\u30e9\u30a4\u30ca\u30fc\u306e\u5f71\u97ff \uff08\u4e0a\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff081 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\u3001\u4e0b\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff080.5 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\uff09\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnar4184-02.jpg\" alt=\"Effect of Liner on Chromatographic Performance for Semivolatiles on a Narrow-Bore Rxi-SVOCms Column\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong><br>Figure 3:<\/strong> \u4e2d\u5bb9\u91cfIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u6eb6\u5a92\u30d4\u30fc\u30af\u304b\u3089\u306e\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3057\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306b\u5bfe\u3059\u308b\u6eb6\u5a92\u306e\u5f71\u97ff\u304c\u8efd\u6e1b\u3055\u308c\u307e\u3059\u3002\u6ce8\u5165\u91cf\u3092\u3055\u3089\u306b\u6e1b\u3089\u3059\u3053\u3068\u3067\u3001\u3055\u3089\u306b\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1509.png\" alt=\"Comparison: Semivolatiles on Narrow-Bore Rxi-SVOCms - IV Liner Article Figure 3\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1509<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31899<\/li><li>31825<\/li><li>31826<\/li><li>32418<\/li><li>46616<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>3mm,<\/li><li>IV liner<\/li><li>PAH<\/li><li>SVOA,<\/li><li>SVOC,<\/li><li>intermediate-volume liner<\/li><li>semivolatiles,<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1509.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong><br>Figure 4:<\/strong> IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001\u5168\u4f53\u7684\u306b\u3088\u308a\u9ad8\u304f\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u304c\u5f97\u3089\u308c\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1511.png\" alt=\"Comparison: Semivolatiles on Narrow-Bore Rxi-SVOCms - IV Liner Article Figure 4\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1511<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31899<\/li><li>31825<\/li><li>31826<\/li><li>32418<\/li><li>46616<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>PAH,<\/li><li>SVOA,<\/li><li>SVOC,<\/li><li>intermediate-volume liner<\/li><li>semivolatile,<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1511.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u9045\u304f\u6eb6\u51fa\u3059\u308b\u30d4\u30fc\u30af\u3067\u3082\u30d4\u30fc\u30af\u9ad8\u3055\u3068\u5bfe\u79f0\u6027\u304c\u6539\u5584\u3055\u308c\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002 \u00a0 \u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1510.png\" alt=\"Comparison: Semivolatiles on Narrow-Bore Rxi-SVOCms - IV Liner Article Figure 5\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1510<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31899<\/li><li>31825<\/li><li>31826<\/li><li>32418<\/li><li>46616<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>PAH,<\/li><li>SVOA,<\/li><li>SVOC<\/li><li>intermediate-volume liner<\/li><li>semivolatile<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1510.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"pah\">\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAHs\uff09\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PAH\u306e\u8a55\u4fa1\u3067\u306f\u3001\u5305\u62ec\u7684\u306aPAH\u306e\u5206\u6790\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30ca\u30ed\u30fc\u30dc\u30a2\u306eRxi-PAH\u30ab\u30e9\u30e0\uff0840 m \u00d7 0.18 mm\u5185\u5f84 \u00d7 0.07 \u00b5m; \u54c1\u756a49316\uff09\u3092\u9078\u629e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306f\u3001\u30d9\u30f3\u30be [b]\u3001[k]\u3001\u304a\u3088\u3073 [j] \u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\u3092\u542b\u3080\u91cd\u8981\u306a\u5316\u5408\u7269\u3092\u5206\u96e2\u3057\u306a\u304c\u3089\u3001\u3088\u308a\u91cd\u3044PAH\u3092\u77ed\u3044\u5206\u6790\u6642\u9593\u3067\u6eb6\u51fa\u3059\u308b\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002PAH\u8a66\u9a13\u306f\u30011 \u00b5g\/mL \u306b\u5e0c\u91c8\u3057\u305f 31 \u7a2e\u985e\u306e\u5316\u5408\u7269 (\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 31899 \u304a\u3088\u3073 32547) \u3092\u4f7f\u7528\u3057\u3066\u884c\u308f\u308c\u3001\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5b9f\u9a13\u3067\u4f7f\u7528\u3057\u305f\u306e\u3068\u540c\u3058\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3068\u6ce8\u5165\u91cf\u3092\u4f7f\u7528\u3057\u3066\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1 \u00b5L\u6ce8\u5165\u306e\u5834\u5408\u3001\u5927\u5bb9\u91cf\u306e\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001\u4e2d\u5bb9\u91cf\u306e IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u3084\u306f\u308a\u6539\u5584\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u5168\u4f53\u7684\u306a\u5b9a\u91cf\u7684\u8a55\u4fa1\u3067\u306fPAH\u306e 94% \u3067\u3088\u308a\u5927\u304d\u306a\u30d4\u30fc\u30af\u9762\u7a4d\u304c\u5f97\u3089\u308c\u300174%\u3067IV\u30e9\u30a4\u30ca\u30fc\u306e\u65b9\u304c\u3088\u308a\u5927\u304d\u306a\u30d4\u30fc\u30af\u9ad8\u3055\u3092\u793a\u3057\u307e\u3057\u305f (<strong>Figure 6<\/strong>)\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u6bd4\u8f03\u3068\u540c\u69d8\u3001\u3053\u308c\u3089\u306e\u7d50\u679c\u306f\u4e21\u65b9\u3068\u3082\u7d71\u8a08\u7684\u306b\u6709\u610f\u3067\u3057\u305f\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u306e\u4e00\u4f8b\u3068\u3057\u3066\u3001<strong>Figure 7<\/strong>\u306b\u30d4\u30fc\u30af\u9762\u7a4d\u3001\u9ad8\u3055\u3001\u5bfe\u79f0\u6027\u306e\u5411\u4e0a\u3092\u793a\u3057\u307e\u3059\u3002\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3068\u6bd4\u8f03\u3057\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u304c\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3078\u3088\u308a\u52b9\u7387\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u3092\u884c\u3044\u3001\u9045\u304f\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3082\u540c\u69d8\u306e\u52b9\u679c\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002 &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">IV\u30e9\u30a4\u30ca\u30fc\u3068\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u6bd4\u8f03\u3057\u305f\u7d50\u679c\u306f\u3088\u308a\u8907\u96d1\u3067\u3057\u305f\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u7d50\u679c\u3068\u306f\u5bfe\u7167\u7684\u306b\u3001PAH\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306e\u65b9\u304c\u7d71\u8a08\u7684\u306b\u9ad8\u304f\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306b\u95a2\u4fc2\u306a\u304f\u3001Rxi-PAH\u30ab\u30e9\u30e0\u5168\u4f53\u3067\u306ePAH\u306e\u4fdd\u6301\u529b\u304c\u9ad8\u3044\u3053\u3068\u306b\u8d77\u56e0\u3059\u308b\u305f\u3081\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u8208\u5473\u6df1\u3044\u3053\u3068\u306b\u3001\u3053\u308c\u3089\u306e\u7d50\u679c\u306f\u7d71\u8a08\u7684\u306b\u6709\u610f\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u30d4\u30fc\u30af\u5e45\u3068\u5206\u96e2\u306b\u95a2\u3057\u3066\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u5927\u90e8\u5206\u306ePAH\u3067\u5b9a\u6027\u7684\u306b\u3088\u308a\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u3068\u9ad8\u3044\u5206\u96e2\u80fd\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<strong>Figure 8<\/strong>\u306f\u3001\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u5c0f\u3055\u304f\u3066\u3082\u3001IV\u30e9\u30a4\u30ca\u30fc\u3067\u5f97\u3089\u308c\u305f\u3088\u308a\u72ed\u3044\u30d4\u30fc\u30af\u306b\u3088\u308a\u3001\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3088\u308a\u3082 PAH\u306e\u30d4\u30fc\u30af\u306e\u5bfe\u79f0\u6027\u3068\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3057\u305f\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u5168\u4f53\u3068\u3057\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3067\u306ePAH\u5206\u6790\u306b\u91cd\u8981\u306a\u5229\u70b9\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> \u30ca\u30ed\u30fc\u30dc\u30a2\u306eRxi-PAH\u30ab\u30e9\u30e0\u3067\u306ePAH\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3078\u306e\u30e9\u30a4\u30ca\u30fc\u306e\u5f71\u97ff\uff08\u4e0a\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff081 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\u3001\u4e0b\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff080.5 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnar4184-06.jpg\" alt=\"Effect of Liner on Chromatographic Performance for PAHs on a Narrow-Bore Rxi-PAH Column\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001\u96e3\u3057\u3044PAH\u306b\u5bfe\u3057\u3066\u30d4\u30fc\u30af\u9762\u7a4d\u3001\u9ad8\u3055\u3001\u304a\u3088\u3073\u5bfe\u79f0\u6027\u304c\u6539\u5584\u3055\u308c\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1512.png\" alt=\"Comparison: PAHs on Narrow-Bore Rxi-PAH - IV Liner Article Figure 7\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1512<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31899<\/li><li>32547<\/li><li>49316<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>PAH,<\/li><li>SVOA,<\/li><li>SVOC,<\/li><li>intermediate-volume liner<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1512.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> \u30d4\u30fc\u30af\u306e\u9ad8\u3055\u304c\u4f4e\u4e0b\u3057\u305f\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u3001\u30d4\u30fc\u30af\u304c\u3088\u308a\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u3063\u305f\u305f\u3081\u3001IV\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u5206\u96e2\u80fd\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002 \u00a0 \u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1513.png\" alt=\"Comparison: PAHs on Narrow-Bore Rxi-PAH - IV Liner Article Figure 8\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1513<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31899<\/li><li>32547<\/li><li>49316<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>PAH,<\/li><li>SVOA,<\/li><li>SVOC,<\/li><li>intermediate-volume liner<\/li><li>semivolatile<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1513.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"pesticides\">\u8fb2\u85ac\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u5f8c\u306e\u5b9f\u9a13\u3067\u306f\u3001\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\u304c\u8fb2\u85ac\u5206\u6790\u306e\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u304b\u3069\u3046\u304b\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u300120 \u7a2e\u985e\u306e\u8fb2\u85ac\uff08\u30ab\u30bf\u30ed\u30b0\u756a\u53f7 32279\u300132280\u300132281\u300132282\u3001\u304a\u3088\u3073 32418\uff09\u30921 \uff5e 10 \u00b5g\/mL \u3067\u542b\u3080\u6a19\u6e96\u7269\u8cea\u3092Rxi-5ms \u30ab\u30e9\u30e0 \uff0820 mx 0.18 mm ID x 0.18 \u00b5m; \u30ab\u30bf\u30ed\u30b0\u756a\u53f7 13402\uff09\u3067\u5206\u6790\u3057\u307e\u3057\u305f\u3002Rxi-5ms\u306f\u3001\u4f4e\u30d6\u30ea\u30fc\u30c9\u30b1\u30df\u30b9\u30c8\u30ea\u30fc\u3067\u5f37\u5316\u3055\u308c\u305f\u6c4e\u7528\u30ab\u30e9\u30e0\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u6ce8\u5165\u91cf\u3068\u30e9\u30a4\u30ca\u30fc\u306e\u30b5\u30a4\u30ba\u306f\u524d\u306e\u5b9f\u9a13\u3068\u540c\u3058\u3082\u306e\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1 \u00b5L\u306e\u6ce8\u5165\u3067\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306e\u5411\u4e0a\u304c\u518d\u3073\u898b\u3089\u308c\u307e\u3057\u305f\u3002<strong>Figure 9<\/strong>\u306f\u3001\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u3088\u308a\u5927\u5bb9\u91cf\u306e\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u304c\u7d71\u8a08\u7684\u306b\u6539\u5584\u3055\u308c\u305f\u3053\u3068\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u3053\u306e\u7d50\u679c\u306f\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u304a\u3088\u3073PAH\u306e\u5b9f\u9a13\u3068\u4e00\u81f4\u3057\u307e\u3057\u305f\u3002\u30d4\u30fc\u30af\u5e45\u3001\u5206\u96e2\u80fd\u3001\u304a\u3088\u3073\u5bfe\u79f0\u6027\u306f\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u4f53\u7a4d\u9593\u3067\u5927\u5e45\u306b\u5909\u5316\u3057\u307e\u305b\u3093\u3067\u3057\u305f\u3002<strong>Figure 10<\/strong>\u306f\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u5f97\u3089\u308c\u308b\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u5897\u52a0\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002IV\u30e9\u30a4\u30ca\u30fc\u306b\u3088\u308a\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u304c\u65e9\u304f\u306a\u308b\u3053\u3068\u3067\u30d4\u30fc\u30af\u306e\u8b58\u5225\u304c\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">0.5 \u00b5L\u6ce8\u5165\u306e\u7d50\u679c\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u304c\u5927\u5e45\u306b\u6e1b\u5c11\u3059\u308b\u3068\u3044\u3046\u70b9\u3067PAH\u306e\u7d50\u679c\u3068\u540c\u69d8\u3067\u3057\u305f\u304c\u3001\u5927\u90e8\u5206\u306e\u5316\u5408\u7269\u3067\u30d4\u30fc\u30af\u5e45\u3001\u5206\u96e2\u80fd\u3001\u5bfe\u79f0\u6027\u306b\u95a2\u3057\u3066\u6539\u5584\u304c\u898b\u3089\u308c\u307e\u3057\u305f \uff08<strong>Figure 9<\/strong>\uff09\u3002\u3057\u304b\u3057\u3001\u7d71\u8a08\u7684\u306a\u9055\u3044\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u306e\u6e1b\u5c11\u306f\u3001\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u4e2d\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u79fb\u9001\u304c\u308f\u305a\u304b\u306b\u4f4e\u4e0b\u3059\u308b\u305f\u3081\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u5b9a\u91cf\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001IV\u30e9\u30a4\u30ca\u30fc\u3067\u89b3\u5bdf\u3055\u308c\u305f\u4e3b\u306a\u6539\u5584\u306e 1 \u3064\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u521d\u671f\u306e\u30d4\u30fc\u30af\u5206\u5272\u304c\u6e1b\u5c11\u3057\u305f\u3053\u3068\u3067\u3059 \uff08<strong>Figure 11<\/strong>\uff09\u3002\u3059\u3079\u3066\u306e\u30e9\u30a4\u30ca\u30fc\u3068\u5bb9\u91cf\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u306f\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u3067\u3042\u308b\u7a0b\u5ea6\u306e\u30d4\u30fc\u30af\u5206\u5272\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u304c\u3001\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u3066 0.5 \u00b5L \u3092\u6ce8\u5165\u3057\u305f\u5834\u5408\u306b\u5206\u5272\u304c\u6700\u3082\u6e1b\u5c11\u3057\u307e\u3057\u305f\u3002\u30d4\u30fc\u30af\u5206\u5272\u3068\u6eb6\u5a92\u306e\u5f71\u97ff\u304c\u6e1b\u5c11\u3059\u308b\u305f\u3081\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3068\u5b9a\u91cf\u306f\u6539\u5584\u3055\u308c\u308b\u306f\u305a\u3067\u3059\u304c\u3001\u30d4\u30fc\u30af\u5206\u5272\u3092\u5b8c\u5168\u306b\u6392\u9664\u3059\u308b\u306b\u306f\u3055\u3089\u306b\u591a\u304f\u306e\u8abf\u6574\u304c\u5fc5\u8981\u3067\u3059\u3002Restek \u306e GC \u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0 \u30d3\u30c7\u30aa \u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001 <a href=\"https:\/\/discover.restek.com\/videos\/gnav3601\/gc-troubleshooting-split-peaks\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/videos\/GNAV3601\/gc-troubleshooting-split-peaks\/\">peak splitting\uff08\u30d4\u30fc\u30af\u5206\u5272\uff09<\/a> \u3084\u305d\u306e\u4ed6\u306e\u554f\u984c\u3092\u8efd\u6e1b\u3059\u308b\u305f\u3081\u306e\u5f79\u7acb\u3064\u30d2\u30f3\u30c8\u304c\u63d0\u4f9b\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5168\u4f53\u3068\u3057\u3066\u30010.5 \u00b5L\u6ce8\u5165\u306e\u5834\u5408\u3001\u8ffd\u52a0\u5bb9\u91cf\u3068\u6eb6\u5a92\u30d4\u30fc\u30af\u304b\u3089\u306e\u8ddd\u96e2\u306b\u3088\u308a\u30d4\u30fc\u30af\u5206\u5272\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u308b\u305f\u3081\u3001IV\u30e9\u30a4\u30ca\u30fc\u306f\u65e9\u671f\u6eb6\u51fa\u306e\u8fb2\u85ac\u306b\u3068\u3063\u3066\u6700\u3082\u52b9\u679c\u7684\u306a\u9078\u629e\u80a2\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> \u30ca\u30ed\u30fc\u30dc\u30a2\u306eRxi-5ms\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u8fb2\u85ac\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3078\u306e\u30e9\u30a4\u30ca\u30fc\u306e\u5f71\u97ff\uff08\u4e0a\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff081 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\u3001\u4e0b\u306e\u30b0\u30e9\u30d5\u306fIV\u30e9\u30a4\u30ca\u30fc\u3068\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\uff080.5 \u00b5L\u6ce8\u5165\uff09\u306e\u6bd4\u8f03\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnar4184-09.jpg\" alt=\"Effect of Liner on Chromatographic Performance for Pesticides on a Narrow-Bore Rxi-5ms Column\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 10:<\/strong> \u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u30661 \u00b5L\u306e\u6ce8\u5165\u6642\u306bIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u5411\u4e0a\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1515.png\" alt=\"Comparison: Pesticides on Narrow-Bore Rxi-5ms - IV Liner Article Figure 10\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1515<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32418<\/li><li>32279<\/li><li>32280<\/li><li>32281<\/li><li>32282<\/li><li>13402<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>intermediate-volume liner<\/li><li>pesticides,<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1515.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 11:<\/strong> \u3059\u3079\u3066\u306e\u30e9\u30a4\u30ca\u30fc\u3068\u6ce8\u5165\u91cf\u306b\u304a\u3044\u3066\u65e9\u671f\u6eb6\u51fa\u5316\u5408\u7269\u306b\u30d4\u30fc\u30af\u5206\u5272\u304c\u8d77\u3053\u308a\u307e\u3057\u305f\u304c\u3001IV\u30e9\u30a4\u30ca\u30fc\u30670.5 \u00b5L\u3092\u6ce8\u5165\u3059\u308b\u3053\u3068\u3067\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1514.png\" alt=\"Comparison: Pesticides on Narrow-Bore Rxi-5ms - IV Liner Article Figure 11\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1514<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32418<\/li><li>32279<\/li><li>32280<\/li><li>32281<\/li><li>32282<\/li><li>13402<\/li><li>23316<\/li><li>27231<\/li><li>23303<\/li><li>24795<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>IV liner<\/li><li>intermediate-volume liner<\/li><li>peak,<\/li><li>pesticides,<\/li><li>solvent<\/li><li>splitting,<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1514.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"reproduciblity\">\u518d\u73fe\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3001\u3059\u3079\u3066\u306e\u5b9f\u9a13\u3067\u5f97\u3089\u308c\u305f\u5168\u5316\u5408\u7269\u306e\u5e73\u5747\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u3092\u3001\u7570\u306a\u308b\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3068\u6ce8\u5165\u91cf\u3067\u6bd4\u8f03\u3057\u307e\u3057\u305f\uff08<strong>Figure 12<\/strong>\uff09\u3002 \u5168\u4f53\u7684\u306b\u3001\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3067\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u9ad8\u3055\u306b\u3064\u3044\u3066\u3001\u90e8\u5206\u5bb9\u91cf\u3068\u5168\u5bb9\u91cf\u306e\u4e21\u65b9\u3067\u3001\u7d71\u8a08\u7684\u306b\u512a\u308c\u305f\u518d\u73fe\u6027\u3092\u793a\u3057\u307e\u3057\u305f\uff08<strong>Table II<\/strong>\uff09\u3002 \u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306e\u7d50\u679c\u3082\u3001\u7d71\u8a08\u7684\u306a\u5dee\u304c\u306a\u304b\u3063\u305f0.5\u00b5L\u6ce8\u5165\u3068\u3001\u3088\u308a\u5927\u5bb9\u91cf\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u5bfe\u79f0\u6027\u304c0.1%\u3057\u304b\u6539\u5584\u3055\u308c\u306a\u304b\u3063\u305f\u4e2d\u5bb9\u91cf\u306e\u6bd4\u8f03\u3092\u9664\u304d\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u518d\u73fe\u6027\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u30d4\u30fc\u30af\u5e45\u3068\u5206\u96e2\u80fd\u306b\u95a2\u3057\u3066\u306f\u3001\u307b\u3068\u3093\u3069\u306e\u6bd4\u8f03\u3067\u6027\u80fd\u306b\u7d71\u8a08\u7684\u306a\u5dee\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u30010.5 \u00b5L\u6ce8\u5165\u3067\u306f\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u306e\u65b9\u304c\u518d\u73fe\u6027\u306e\u9ad8\u3044\u7d50\u679c\u304c\u5f97\u3089\u308c\u30011.0\u00b5L \u6ce8\u5165\u3067\u306fIV\u30e9\u30a4\u30ca\u30fc\u306e\u65b9\u304c\u518d\u73fe\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5e45\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u5e45\u3068\u5206\u96e2\u80fd\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u5185\u306e\u4f4d\u7f6e (\u6eb6\u51fa\u306e\u521d\u671f\u3068\u5f8c\u671f\u3001\u307e\u305f\u306f\u7b49\u6e29\u5206\u6790\u306a\u3069) \u306b\u3088\u3063\u3066\u5927\u304d\u304f\u5f71\u97ff\u3055\u308c\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u9055\u3044\u306f\u30e9\u30a4\u30ca\u30fc\u4ee5\u5916\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u306b\u3088\u308a\u5927\u304d\u306a\u5f71\u97ff\u3092\u53d7\u3051\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u518d\u73fe\u6027\u306e\u5411\u4e0a\u306f\u3001IV\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u9593\u5bb9\u7a4d\u306b\u8d77\u56e0\u3059\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002IV\u30e9\u30a4\u30ca\u30fc\u306b\u306f\u3001\u3088\u308a\u5c0f\u3055\u3044\u5bb9\u7a4d\u306e\u30e9\u30a4\u30ca\u30fc\u306e\u80fd\u529b\u3092\u62bc\u3057\u4e0a\u3052\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u6ce8\u5165\u91cf\u304c\u3088\u308a\u9069\u5207\u306b\u542b\u307e\u308c\u307e\u3059\u3002\u540c\u69d8\u306b\u3001\u5316\u5408\u7269\u306f\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082IV\u30e9\u30a4\u30ca\u30fc\u304b\u3089\u30ab\u30e9\u30e0\u306b\u52b9\u7387\u7684\u306b\u79fb\u9001\u3055\u308c\u308b\u305f\u3081\u3001\u7279\u306b\u5f8c\u304b\u3089\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306e\u5834\u5408\u306b\u5909\u5316\u304c\u751f\u3058\u308b\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 12:<\/strong> \u7570\u306a\u308b\u30e9\u30a4\u30ca\u30fc\u30b5\u30a4\u30ba\u3068\u6ce8\u5165\u91cf\u3054\u3068\u306e\u30d4\u30fc\u30af\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u5e73\u5747% RSD\u3002 \u00a0 \u00a0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnar4184-12.jpg\" alt=\"Average %RSD for different peak parameters across various liner sizes and injection volumes.\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u7570\u306a\u308b\u30d4\u30fc\u30af\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u304a\u3051\u308b\u512a\u308c\u305f\u518d\u73fe\u6027\uff08\u7d71\u8a08\u7684\u306b\u6709\u610f\u306a\u5e73\u5747% RSD\u5024\u304c\u4f4e\u3044\u3001p &lt; 0.05\uff09\u30e9\u30a4\u30ca\u30fc\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30e9\u30a4\u30ca\u30fcID<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u9762\u7a4d<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u9ad8\u3055<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u5e45<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u5206\u96e2\u80fd<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u30c6\u30fc\u30ea\u30f3\u30b0<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">0.5 \u00b5L \u6ce8\u5165\uff08IV vs \u5c0f\u5bb9\u91cf\uff09<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u5c0f\u5bb9\u91cf<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u5c0f\u5bb9\u91cf<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">1 \u00b5L \u6ce8\u5165\uff08IV vs \u5927\u5bb9\u91cf\uff09<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Full capacity\uff08IV vs \u5c0f\u5bb9\u91cf\uff09<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Mid-capacity\uff08IV vs \u5927\u5bb9\u91cf\uff09<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">IV<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">ND<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u5927\u5bb9\u91cf<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">ND = \u7d71\u8a08\u7684\u306a\u5dee\u7570\u306a\u3057\uff08p &gt; 0.05\uff09<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"summary\">\u5168\u4f53\u7684\u306a\u8a55\u4fa1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III<\/strong>\u306f\u3001\u3053\u308c\u3089\u3059\u3079\u3066\u306e\u5b9f\u9a13\u306e\u7d71\u8a08\u7d50\u679c\u3092\u307e\u3068\u3081\u305f\u3082\u306e\u3067\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\uff0b\u30ca\u30ed\u30fc\u30dc\u30a2 GC \u30ab\u30e9\u30e0\u306e\u7d44\u307f\u5408\u308f\u305b\u306e\u5834\u5408\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u304c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u6027\u80fd\u306b\u3069\u306e\u3088\u3046\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3059\u304b\u306e\u30ec\u30d9\u30eb\u8a55\u4fa1\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u300250 \u4ef6\u306e\u6bd4\u8f03\u306e\u3046\u3061\u300143 \u4ef6 (86%) \u3067\u306f\u3001\u4e2d\u5bb9\u91cf\u306eIV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u5c0f\u5bb9\u91cf\u3068\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u6539\u5584\u3055\u308c\u305f (22\/50) \u307e\u305f\u306f\u540c\u7b49\u306e (21\/50) \u6027\u80fd\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002\u7d50\u679c\u306f\u30d4\u30fc\u30af\u9762\u7a4d\u3068\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u6700\u3082\u9855\u8457\u3067\u3042\u308a\u3001\u3053\u308c\u3089\u306f\u6b63\u78ba\u306a\u30d4\u30fc\u30af\u306e\u540c\u5b9a\u3068\u5b9a\u91cf\u5316\u306b\u91cd\u8981\u3067\u3059\u3002\u30d4\u30fc\u30af\u5e45\u3001\u5206\u96e2\u80fd\u3001\u5bfe\u79f0\u6027\u306b\u304a\u3044\u3066\u306f\u3001\u52b9\u679c\u304c\u3055\u307e\u3056\u307e\u3067\u3057\u305f\u304c\u3001\u3053\u308c\u3089\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u306f\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6 (\u6e29\u5ea6\u3001\u30ab\u30e9\u30e0\u6db2\u76f8\u3001\u6eb6\u89e3\u5ea6\u306a\u3069) \u3084\u6eb6\u51fa\u6642\u9593\u306b\u3088\u3063\u3066\u3082\u5f37\u304f\u5f71\u97ff\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30c7\u30fc\u30bf\u306b\u57fa\u3065\u3044\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u306f\u5c0f\u5bb9\u91cf\u304a\u3088\u3073\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u3001\u3088\u308a\u30d0\u30e9\u30f3\u30b9\u6539\u5584\u3055\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3068IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u5c0f\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3088\u308a\u3082\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3067\u304d\u308b\u305f\u3081\u3001\u6eb6\u5a92\u3068\u30e9\u30a4\u30ca\u30fc\u5bb9\u91cf\u306b\u3088\u308b\u5236\u9650\u304c\u8efd\u6e1b\u3055\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u6bd4\u8f03\u3057\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u3088\u308a\u901f\u304f\u3001\u3088\u308a\u72ed\u3044\u30d0\u30f3\u30c9\u3067\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u56fa\u6709\u306e\u9ad8\u3044\u52b9\u7387\u3092\u52b9\u679c\u7684\u306b\u6d3b\u7528\u3067\u304d\u307e\u3059\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7d50\u8ad6\u3068\u3057\u3066\u3001IV\u30e9\u30a4\u30ca\u30fc\u306e\u4e2d\u5bb9\u91cf\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u9ad8\u901f\u3067\u611f\u5ea6\u304c\u9ad8\u304f\u3001\u9ad8\u3044\u518d\u73fe\u6027\u306e\u5206\u6790\u306b\u8ca2\u732e\u3057\u3001\u30e9\u30dc\u304c\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u5229\u70b9\u3092\u6700\u5927\u9650\u306b\u6d3b\u7528\u3067\u304d\u308b\u3088\u3046\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002\u65e2\u5b58\u306e\u65b9\u6cd5\u3092\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306b\u5207\u308a\u66ff\u3048\u308b\u5834\u5408\u306f\u3001\u30d4\u30fc\u30af\u306e\u5206\u96e2\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u4ed6\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u9069\u5207\u306b\u30b9\u30b1\u30fc\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002Restek\u306e\u7121\u6599\u30aa\u30f3\u30e9\u30a4\u30f3\u30bd\u30d5\u30c8\u3001Pro <em>EZ<\/em>LC\u30e1\u30bd\u30c3\u30c9\u30c8\u30e9\u30f3\u30b9\u30ec\u30fc\u30bf\u30fc\u306f\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u306e\u305f\u3081\u306e\u9069\u5207\u306a\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3084\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u69cb\u7bc9\u3059\u308b\u305f\u3081\u306e\u8fc5\u901f\u3067\u7c21\u5358\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> \u3053\u3053\u3067\u8a55\u4fa1\u3055\u308c\u305f\u5b9f\u9a13\u6bd4\u8f03\u306e86\uff05\uff0843\/50\uff09\u304c\u3001\u30ca\u30ed\u30fc\u30dc\u30a2\u30ab\u30e9\u30e0\u3067IV\u30e9\u30a4\u30ca\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u6027\u80fd\u304c\u6539\u5584\u3055\u308c\u308b\u304b\u3001\u7d71\u8a08\u7684\u306a\u5dee\u304c\u3042\u308b\u304b\u3092\u793a\u3057\u307e\u3057\u305f\u3002 &nbsp; &nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td rowspan=\"2\">&nbsp;<\/td><td colspan=\"5\"><strong>\u6027\u80fd\u306e\u6700\u3082\u512a\u308c\u305f\u30e9\u30a4\u30ca\u30fc (p &lt; 0.05)<\/strong><\/td><\/tr><tr><td><strong>\u9762\u7a4d\u306e\u5897\u52a0<\/strong><\/td><td><strong>\u9ad8\u3055\u306e\u5897\u52a0<\/strong><\/td><td><strong>\u30d4\u30fc\u30af\u5e45\u306e\u6e1b\u5c11<\/strong><\/td><td><strong>\u5206\u96e2\u80fd\u306e\u5411\u4e0a<\/strong><\/td><td><strong>\u30c6\u30fc\u30ea\u30f3\u30b0\u306e\u6e1b\u5c11<\/strong><\/td><\/tr><tr><td colspan=\"6\"><strong>\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269<\/strong><\/td><\/tr><tr><td>IV vs. larger (1 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>ND<\/td><td>ND<\/td><\/tr><tr><td>IV vs. smaller (0.5 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>IV<\/td><td>IV<\/td><td>IV<\/td><\/tr><tr><td colspan=\"6\"><strong>\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAH\uff09<\/strong><\/td><\/tr><tr><td>IV vs. larger (1 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>ND<\/td><td>ND<\/td><\/tr><tr><td>IV vs. smaller (0.5 \u00b5L)<\/td><td>smaller<\/td><td>smaller<\/td><td>ND<\/td><td>ND<\/td><td>ND<\/td><\/tr><tr><td colspan=\"6\"><strong>\u8fb2\u85ac<\/strong><\/td><\/tr><tr><td>IV vs. larger (1 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>ND<\/td><td>ND<\/td><\/tr><tr><td>IV vs. smaller (0.5 \u00b5L)<\/td><td>smaller<\/td><td>smaller<\/td><td>ND<\/td><td>ND<\/td><td>ND<\/td><\/tr><tr><td colspan=\"6\"><strong>\u518d\u73fe\u6027<\/strong><\/td><\/tr><tr><td>IV vs. larger (1 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>IV<\/td><\/tr><tr><td>IV vs. smaller (0.5 \u00b5L)<\/td><td>IV<\/td><td>IV<\/td><td>smaller<\/td><td>smaller<\/td><td>ND<\/td><\/tr><tr><td>Full capacity (smaller vs. IV)<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>ND<\/td><td>IV<\/td><\/tr><tr><td>Mid-capacity (larger vs. IV)<\/td><td>IV<\/td><td>IV<\/td><td>ND<\/td><td>ND<\/td><td>larger<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">ND = ND = \u7d71\u8a08\u7684\u306a\u5dee\u7570\u306a\u3057\uff08p &gt; 0.05\uff09 &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27231\">                                \u30ab\u30bf\u30ed\u30b0No. 27231                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, \u4e2d\u5bb9\u91cf IV\u30e9\u30a4\u30ca\u30fc, \u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc, \u30a6\u30fc\u30eb\u5165\u308a, 3.0 mm x 6.5 x 78.5, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27231\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27232\">                                \u30ab\u30bf\u30ed\u30b0No. 27232                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, \u4e2d\u5bb9\u91cf IV\u30e9\u30a4\u30ca\u30fc, \u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc, \u30a6\u30fc\u30eb\u5165\u308a, 3.0 mm x 5 x 95, Shimadzu GC\u7528, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27232\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46616\">                                \u30ab\u30bf\u30ed\u30b0No. 46616                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Capillary Column, 20 m, 0.15 mm ID, 0.15 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46616\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/49316\">                                \u30ab\u30bf\u30ed\u30b0No. 49316                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-PAH GC Capillary Column, 40 m, 0.18 mm ID, 0.07 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/49316\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13402\">                                \u30ab\u30bf\u30ed\u30b0No. 13402                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-5ms GC Capillary Column, 20 m, 0.18 mm ID, 0.18 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13402\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>IV\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u5c0f\u5bb9\u91cf\u3084\u5927\u5bb9\u91cf\u30e9\u30a4\u30ca\u30fc\u3068\u306e\u30d0\u30e9\u30f3\u30b9\u3092\u53d6\u3063\u305f\u4e2d\u5bb9\u91cf\u306e\u30e9\u30a4\u30ca\u30fc\u3067\u3059\u3002\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306e\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u3067\u6ce8\u5165\u91cf\u3067\u56f0\u3063\u305f\u3089\u3001IV\u30e9\u30a4\u30ca\u30fc\u3092\u30c1\u30a7\u30c3\u30af\uff01<\/p>\n","protected":false},"author":34,"featured_media":7159,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789,789],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[454,599],"class_list":["post-45332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-topaz-liners"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"},{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR4184-1024x550.jpg",1024,550,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0},{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":599,"user_id":0,"is_guest":1,"slug":"mark-badger","display_name":"Mark Badger","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Mark","last_name":"Badger","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45332"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45332\/revisions"}],"predecessor-version":[{"id":104996,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45332\/revisions\/104996"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7159"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45332"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45332"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45332"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45332"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45332"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45332"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}